Check identifier 21039 — Order status (disconnect)
Check identifier 21039 · EDIFACT message type IFTSTA · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 21039 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| STATUSMITTEILUNG [ ] * | — | object[] | Must | — |
| positionsdaten [ ] * | — | object[] | Must | — |
| allgemeineInformationenText 00010 | Allgemeine Informationen | string | X | — |
| antwortstatus 00020 | antwortstatus | string | X | — |
| antwortstatusCodeliste 00030 | antwortstatusCodeliste | string | X | — |
| auftragsstatus 00040 | Order status | Enum Auftragsstatus | X | — |
GESCHEITERT | — | — | X | — |
ERFOLGREICH | — | — | X | — |
LIEFERUNG_GEPLANT | — | — | X | — |
GEPLANT | — | — | X | — |
ZUGESTIMMT | — | — | X | — |
WIDERSPROCHEN | — | — | X | — |
STOERUNGSFREI | — | — | X | — |
GESTOERT | — | — | X | — |
FESTGESTELLTE_STOERUNG | — | — | X | — |
VERMUTETE_STOERUNG | — | — | X | — |
ABGELEHNT | — | — | X | — |
BEENDET | — | — | X | — |
ANTWORT_DRITTER | — | — | X | — |
BESTAETIGT | — | — | X | — |
UMGESETZT | — | — | X | — |
ENFG_STROMSPEICHER_UND_VERLUSTENERGIE | — | — | X | — |
ENFG_ELEKTRISCH_ANGETRIEBENE_WAERMEPUMPEN | — | — | X | — |
ENFG_UMLAGEERHEBUNG_BEI_ANLAGEN_ZUR_VERSTROMUNG_VON_KUPPELGASEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_GRUENEN_WASSERSTOFF | — | — | X | — |
ENFG_STROMKOSTENINTENSIVE_UNTERNEHMEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_WASSERSTOFF_IN_STROMKOSTENINTENSIVEN_UNTERNEHMEN | — | — | X | — |
ENFG_SCHIENENBAHNEN | — | — | X | — |
ENFG_ELEKTRISCHE_BETRIEBENE_BUSSEN_IM_LINIENVERKEHR | — | — | X | — |
ENFG_LANDSTROMANLAGEN | — | — | X | — |
AENDERUNG_DER_DATEN | — | — | X | — |
KEINE_AENDERUNG_DER_DATEN | — | — | X | — |
ZEITREIHE_AKZEPTIERT | — | — | X | — |
ZEITREIHE_NICHT_AKZEPTIERT | — | — | X | — |
| fertigstellungsdatum 00050 | fertigstellungsdatum | string (date-time) | X | — |
| lokationsId * 00060 | lokationsId | string | X | — |
| positionsnummer * 00070 | positionsnummer | integer | Must | — |
| sendungsposition 00080 | sendungsposition | integer | Must | — |
| statusObjekt 00090 | Status object | Enum Statusobjekt | X | — |
MSBWECHSEL | — | — | X | — |
UMBAUMELO | — | — | X | — |
ERSTEINBAUIMS | — | — | X | — |
ERSTEINBAUMME | — | — | X | — |
GERAET | — | — | X | — |
ANGEBOTANFRAGE | — | — | X | — |
STATUSBESTELLUNG | — | — | X | — |
LIEFERSCHEIN | — | — | X | — |
SPERREN | — | — | X | — |
ENTSPERREN | — | — | X | — |
PRIVILEGIERUNG_NACH_ENFG | — | — | X | — |
VERAENDERUNGSSTATUS_DER_DATEN | — | — | X | — |
TURNUSAUSLESUNG | — | — | X | — |
PRUEFSTATUS_ANTWORT_SUMMENZEITREIHEN | — | — | X | — |
ABWEISUNG_SUMMENZEITREIHE | — | — | X | — |
PRUEFSTATUS_SUMMENZEITREIHE | — | — | X | — |
DATENSTATUS_SUMMENZEITREIHE | — | — | X | — |
ABWEISUNG_STATUSMELDUNG_AENDERUNG | — | — | X | — |
AUSFALLARBEIT | — | — | X | — |
FAHRPLANANTEIL | — | — | X | — |
GEGENVORSCHLAG_AUSFALLARBEIT | — | — | X | — |
GEGENVORSCHLAG_FAHRPLANANTEIL | — | — | X | — |
| transaktionsdaten * | — | object | Must | — |
| dokumentennummer * 00100 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| nachrichtendatum * 00110 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00120 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator 00130 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00140 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00150 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00160 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00170 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 21039 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 IFTSTA00020 | Multimodal status report | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 18A00040 | Edition 2018 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z3300070 | GPKE message(s) | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MR00120 | Message recipient | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33200160 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MS00170 | Document-/message sender or sender | — | X | — |
303900180 | MP-ID | — | X | — |
3055 900190 | GS1 | — | X | — |
3055 29300200 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33200210 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG14.CNI | — | — | Must | — |
149000220 | Transaction number | — | X | [911] |
| SG14.LOC | — | — | Must | — |
3227 17200230 | Reporting point | — | X | — |
322500240 | Identifier | — | X | [950] [506] |
| SG15.STS | — | — | Must | — |
9015 Z3700250 | Order status disconnect | — | X | — |
4405 Z1300260 | failed | — | X | ([91] ⊻ [133]) ∧ [20] |
4405 Z1400270 | successful | — | X | [91] ⊻ [133] |
4405 Z3200280 | rejected | — | X | [92] ⊻ [134] |
901300290 | Code of the check step | — | X | ([93] ⊻ [94] ⊻ [107]) |
1131 E_047200300 | EBD no. E_0472 | — | X | — |
1131 E_050100310 | EBD no. E_0501 | — | X | [20] |
1131 E_100200320 | EBD no. E_1002 | — | X | [20] |
1131 E_100300330 | EBD no. E_1003 | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 Z1300340 | Check identifier | — | X | — |
1154 2103900350 | GPKE, Awh disconnection proc. Gas / Order status (disconnect) | — | X | — |
| SG15.DTM | — | — | Must | [77] |
2005 29300360 | Completion date/time | — | X | — |
238000370 | Date or time or time span, value | — | X | [931] [495] |
2379 30300380 | CCYYMMDDHHMMZZZ | — | X | — |
| SG25.GID | — | — | Must | — |
149600390 | Consignment item | — | X | [903] |
| SG25.FTX | — | — | Must | — |
4451 ACB00400 | Additional information (for general notes) | — | X | — |
444000410 | Free text | — | X | — |
| SG15.STS | — | — | Must | — |
9015 Z3800420 | Order status reconnect | — | X | — |
4405 Z1300430 | failed | — | X | [95] ⊻ [137] |
4405 Z1400440 | successful | — | X | [95] ⊻ [137] ⊻ [96] ⊻ [138] |
901300450 | Code of the check step | — | X | ((([97] ⊻ [98]) ∧ ([95] ⊻ [137])) ⊻ [99] ⊻ [139]) |
1131 E_048700460 | EBD no. E_0487 | — | X | — |
1131 E_049900470 | EBD no. E_0499 | — | X | — |
1131 E_100500480 | EBD no. E_1005 | — | X | — |
1131 E_102000490 | EBD no. E_1020 | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 Z1300500 | Check identifier | — | X | — |
1154 2103900510 | GPKE, Awh disconnection proc. Gas / Order status (disconnect) | — | X | — |
| SG15.DTM | — | — | Must | [80] |
2005 29300520 | Completion date/time | — | X | — |
238000530 | Date or time or time span, value | — | X | [931] [495] |
2379 30300540 | CCYYMMDDHHMMZZZ | — | X | — |
| SG25.GID | — | — | Must | — |
149600550 | Consignment item | — | X | [903] |
| SG25.FTX | — | — | Must | — |
4451 ACB00560 | Additional information (for general notes) | — | X | — |
444000570 | Free text | — | X | — |
| UNT | — | — | Must | — |
007400580 | Number of segments in a message | — | X | — |
006200590 | Message reference number | — | X | — |
Conditions of this table
The free text of the 25 conditions referenced by the rows above. All conditions of the message type are listed in the condition index IFTSTA.
| Marker | Condition |
|---|---|
| [20] | If MP-ID in SG1 NAD+MR in the role LF |
| [77] | If STS+Z37+Z14 is present in this SG14 |
| [80] | If STS+Z38+Z14 is present in this SG14 |
| [91] | If DE1131 = E_0472 in this STS |
| [92] | If DE1131 = E_0501 in this STS |
| [93] | If STS+Z37+Z13 present, only codes from the EBD cluster "failed" are possible. |
| [94] | If STS+Z37+Z14 present, only codes from the EBD cluster "successful" are possible. |
| [95] | If DE1131 = E_0499 in this STS |
| [96] | If DE1131 = E_0487 in this STS |
| [97] | If STS+Z38+Z13 present, only codes from the EBD cluster "failed" are possible. |
| [98] | If STS+Z38+Z14 present, only codes from the EBD cluster "successful" are possible. |
| [99] | If DE1131 = E_0487 in this STS, only the code A01 is possible. |
| [107] | If STS+Z37+Z32 present, only codes from the EBD cluster "rejection" are possible. |
| [133] | If DE1131 = E_1003 in this STS |
| [134] | If DE1131 = E_1002 in this STS |
| [137] | If DE1131 = E_1005 in this STS |
| [138] | If DE1131 = E_1020 in this STS |
| [139] | If DE1131 = E_1020 in this STS, only the code A01 is possible. |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [506] | Note: Use of the ID of the market location |
| [903] | Format: Possible value: 1 |
| [911] | Format: Possible values: 1 to n, starting at 1 for each message and ascending consecutively |
| [931] | Format: ZZZ = +00 |
| [950] | Format: market location ID |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ÜNB.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Order status (disconnect) |
| AHB | IFTSTA AHB |
| Decision tree | E_1002 · E_1003 · E_1005 · E_1020 · E_0472 · E_0501 · E_0499 · E_0487 |
| Transmission channel | AS4 |
This check identifier is used in 18 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| AWH disconnection processes gas | Interruption of grid connection use (disconnect) on instruction of the LF | NB → LF | Result of the disconnection order |
| AWH disconnection processes gas | Interruption of grid connection use (disconnect) on instruction of the LF | NB → MSB | Result of the disconnection order |
| AWH disconnection processes gas | Restoration of grid connection use (reconnect) on instruction from the LF | NB → LF | Result of the reconnection order |
| AWH disconnection processes gas | Restoration of grid connection use (reconnect) on instruction from the LF | NB → MSB | Result of the reconnection order |
| AWH disconnection processes gas | Restoration of grid connection use at start of supply | NB → MSB | Result of the reconnection order |
| GPKE part 2 | Interruption of grid connection use (disconnect) on instruction of the LF | NB → LF | Result of the disconnection order |
| GPKE part 2 | Interruption of grid connection use (disconnect) on instruction of the LF | NB → MSB | Result of the disconnection order |
| GPKE part 2 | Interruption of grid connection use (disconnect) on instruction of the LF | NB → ÜNB | Result of the disconnection order |
| GPKE part 2 | Restoration of grid connection use (reconnect) on instruction from the LF | NB → LF | Result of the reconnection order |
| GPKE part 2 | Restoration of grid connection use (reconnect) on instruction from the LF | NB → MSB | Result of the reconnection order |
| GPKE part 2 | Restoration of grid connection use (reconnect) on instruction from the LF | NB → ÜNB | Result of the reconnection order |
| GPKE part 2 | Restoration of grid connection use at start of supply | NB → MSB | Result of the reconnection order |
| GPKE part 2 | Restoration of grid connection use at start of supply | NB → ÜNB | Result of the reconnection order |
| Application guide for gas disconnection processes | Interruption of grid connection use (disconnect) on instruction of the LF | NB → LF | Result of the disconnection order |
| Application guide for gas disconnection processes | Interruption of grid connection use (disconnect) on instruction of the LF | NB → MSB | Result of the disconnection order |
| Application guide for gas disconnection processes | Restoration of grid connection use (reconnect) on instruction from the LF | NB → LF | Result of the reconnection order |
| Application guide for gas disconnection processes | Restoration of grid connection use (reconnect) on instruction from the LF | NB → MSB | Result of the reconnection order |
| Application guide for gas disconnection processes | Restoration of grid connection use at start of supply | NB → MSB | Result of the reconnection order |
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.
Responses: No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.
Check identifiers of the same AHB table: No other check identifier of message type IFTSTA has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 77 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
No test case exists for this check identifier in the test data of the format version. There is therefore no example message here — not even a reconstructed one: on a page that promises evidence, an invented message would be worse than none.