Check identifier 21035 — Resp. to deliv. note
Check identifier 21035 · EDIFACT message type IFTSTA · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 21035 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| STATUSMITTEILUNG [ ] * | — | object[] | Must | — |
| positionsdaten [ ] * | — | object[] | Must | — |
| antwortstatus * 00010 | antwortstatus | string | X | — |
| antwortstatusCodeliste * 00020 | antwortstatusCodeliste | string | X | — |
| auftragsstatus * 00030 | Order status | Enum Auftragsstatus | X | — |
GESCHEITERT | — | — | X | — |
ERFOLGREICH | — | — | X | — |
LIEFERUNG_GEPLANT | — | — | X | — |
GEPLANT | — | — | X | — |
ZUGESTIMMT | — | — | X | — |
WIDERSPROCHEN | — | — | X | — |
STOERUNGSFREI | — | — | X | — |
GESTOERT | — | — | X | — |
FESTGESTELLTE_STOERUNG | — | — | X | — |
VERMUTETE_STOERUNG | — | — | X | — |
ABGELEHNT | — | — | X | — |
BEENDET | — | — | X | — |
ANTWORT_DRITTER | — | — | X | — |
BESTAETIGT | — | — | X | — |
UMGESETZT | — | — | X | — |
ENFG_STROMSPEICHER_UND_VERLUSTENERGIE | — | — | X | — |
ENFG_ELEKTRISCH_ANGETRIEBENE_WAERMEPUMPEN | — | — | X | — |
ENFG_UMLAGEERHEBUNG_BEI_ANLAGEN_ZUR_VERSTROMUNG_VON_KUPPELGASEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_GRUENEN_WASSERSTOFF | — | — | X | — |
ENFG_STROMKOSTENINTENSIVE_UNTERNEHMEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_WASSERSTOFF_IN_STROMKOSTENINTENSIVEN_UNTERNEHMEN | — | — | X | — |
ENFG_SCHIENENBAHNEN | — | — | X | — |
ENFG_ELEKTRISCHE_BETRIEBENE_BUSSEN_IM_LINIENVERKEHR | — | — | X | — |
ENFG_LANDSTROMANLAGEN | — | — | X | — |
AENDERUNG_DER_DATEN | — | — | X | — |
KEINE_AENDERUNG_DER_DATEN | — | — | X | — |
ZEITREIHE_AKZEPTIERT | — | — | X | — |
ZEITREIHE_NICHT_AKZEPTIERT | — | — | X | — |
| positionsnummer * 00040 | positionsnummer | integer | Must | — |
| vorgangsreferenznummer * 00050 | vorgangsreferenznummer | string | X | — |
| ansichtSender [ ] | — | object[] | May | — |
| leistungsperiode 00060 | leistungsperiode | string | X | — |
| tarifstufe 00070 | Tarifstufe | Enum Tarifstufe | Must | — |
TARIFSTUFE_0 | — | — | Must | — |
TARIFSTUFE_1 | — | — | Must | — |
TARIFSTUFE_2 | — | — | Must | — |
TARIFSTUFE_3 | — | — | Must | — |
TARIFSTUFE_4 | — | — | Must | — |
TARIFSTUFE_5 | — | — | Must | — |
TARIFSTUFE_6 | — | — | Must | — |
TARIFSTUFE_7 | — | — | Must | — |
TARIFSTUFE_8 | — | — | Must | — |
TARIFSTUFE_9 | — | — | Must | — |
| verwendungAb 00080 | verwendungAb | string (date-time) | X | — |
| verwendungBis 00090 | verwendungBis | string (date-time) | X | — |
| menge | — | object | May | — |
| einheit 00100 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | Must | — |
W | — | — | Must | — |
WH | — | — | Must | — |
KW | — | — | Must | — |
KWH | — | — | Must | — |
KVARH | — | — | Must | — |
MW | — | — | Must | — |
MWH | — | — | Must | — |
STUECK | — | — | Must | — |
KUBIKMETER | — | — | Must | — |
STUNDE | — | — | Must | — |
TAG | — | — | Must | — |
MONAT | — | — | Must | — |
JAHR | — | — | Must | — |
PROZENT | — | — | Must | — |
ANZAHL | — | — | Must | — |
VAR | — | — | Must | — |
KVAR | — | — | Must | — |
VARH | — | — | Must | — |
KWHK | — | — | Must | — |
Z16 | — | — | Must | — |
KWT | — | — | Must | — |
WATT_PRO_QUADRATMETER | — | — | Must | — |
METER_PRO_SEKUNDE | — | — | Must | — |
| wert 00110 | Value | number (float) | Must | — |
| transaktionsdaten * | — | object | Must | — |
| dokumentennummer * 00120 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| nachrichtendatum * 00130 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00140 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00150 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00160 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00170 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00180 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00190 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 21035 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 IFTSTA00020 | Multimodal status report | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 18A00040 | Edition 2018 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z3300070 | GPKE message(s) | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MR00120 | Message recipient | — | X | — |
303900130 | MP-ID | — | X | [27] |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MS00160 | Document-/message sender or sender | — | X | — |
303900170 | MP-ID | — | X | [27] |
3055 900180 | GS1 | — | X | — |
3055 29300190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG14.CNI | — | — | Must | — |
149000200 | Transaction number | — | X | [911] |
| SG15.STS | — | — | Must | — |
9015 Z2500210 | Status of the delivery note | — | X | — |
4405 Z3000220 | agreed | — | X | — |
4405 Z3100230 | objected | — | X | — |
901300240 | Code of the check step | — | X | [49] ∨ [50] |
1131 E_045600250 | EBD no. E_0456 | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 Z1300260 | Check identifier | — | X | — |
1154 2103500270 | GPKE / Response message to delivery note | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 ACW00280 | Reference number of a preceding message | — | X | — |
115400290 | Reference number | — | X | [512] |
| SG16.EFI | — | — | Must | — |
7008 Z0100300 | Sender view | — | X | — |
| SG16.DTM | — | — | Must | [31] |
2005 16300310 | Processing, start date/time | — | X | — |
238000320 | Date or time or time span, value | — | X | [UB1] ∧ [495] |
2379 30300330 | CCYYMMDDHHMMZZZ | — | X | — |
| SG16.DTM | — | — | Must | [33] |
2005 16400340 | Processing, end date/time | — | X | — |
238000350 | Date or time or time span, value | — | X | [UB1] ∧ [495] |
2379 30300360 | CCYYMMDDHHMMZZZ | — | X | — |
| SG16.DTM | — | — | Must | [32] |
2005 30600370 | Demand period | — | X | — |
238000380 | Date or time or time span, value | — | X | — |
2379 61000390 | CCYYMM | — | X | — |
| SG16.QTY | — | — | Must | — |
6063 Z2000400 | Tariff level 0 | — | X | — |
6063 Z2100410 | Tariff level 1 | — | X | — |
6063 Z2200420 | Tariff level 2 | — | X | — |
6063 Z2300430 | Tariff level 3 | — | X | — |
6063 Z2400440 | Tariff level 4 | — | X | — |
6063 Z2500450 | Tariff level 5 | — | X | — |
6063 Z2600460 | Tariff level 6 | — | X | — |
6063 Z2700470 | Tariff level 7 | — | X | — |
6063 Z2800480 | Tariff level 8 | — | X | — |
6063 Z2900490 | Tariff level 9 | — | X | — |
606000500 | Quantity | — | X | [902] [906] ∧ [530] |
6411 KWH00510 | kilowatt hour | — | X | — |
6411 KWT00520 | kilowatt | — | X | — |
6411 K300530 | kilovolt ampere reactive hour | — | X | — |
6411 K500540 | kilovolt ampere (reactive) | — | X | — |
| UNT | — | — | Must | — |
007400550 | Number of segments in a message | — | X | — |
006200560 | Message reference number | — | X | — |
Conditions of this table
The free text of the 15 conditions referenced by the rows above. All conditions of the message type are listed in the condition index IFTSTA.
| Marker | Condition |
|---|---|
| [27] | Only MP-ID from the electricity division |
| [31] | If in this SG16 KWH/K3 is present in QTY in DE6411. |
| [32] | If in this SG16 KWT/K5 is present in QTY in DE6411. |
| [33] | If DTM+163 is present in this SG16. |
| [49] | If STS+Z25+Z30 present, only codes from the EBD cluster "consent" are possible. |
| [50] | If STS+Z25+Z31 present, only codes from the EBD cluster "rejection" are possible. |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [512] | Note: From MSCONS BGM DE1004 |
| [530] | Note: State here the work or power that the sender of the IFTSTA would have expected in the delivery note for the period / performance period it specified. |
| [902] | Format: Value may only be positive or 0 |
| [906] | Format: max. 3 decimal places |
| [911] | Format: Possible values: 1 to n, starting at 1 for each message and ascending consecutively |
| [931] | Format: ZZZ = +00 |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF and NB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Transmission of the delivery note for grid usage settlement | GPKE part 2 | Electricity | Step 2 |
| NB | NB | Transmission of the delivery note for grid usage settlement | GPKE part 2 | Electricity | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Resp. on deliv. note |
| AHB | IFTSTA AHB |
| Decision tree | E_0456 |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 2 | Transmission of the delivery note for the grid usage settlement | LF → NB | Response message on delivery note |
Transaction and responses
Role of this check identifier: response message. Basis: the title or the action of the Prüfi table begins with “response message”. A response message carries no status field and is not a response in the sense of a decision tree.
Which messages respond to this
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Response | 29002 | Rejection IFTSTA | COMDIS | from the step sequence |
This column is the inverse of the assignment on the response pages — not the next step of a list. The process source says of its own steps that they are »possible messages, not a sequence«.
Check identifiers of the same AHB table: No other check identifier of message type IFTSTA has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 71 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
No test case exists for this check identifier in the test data of the format version. There is therefore no example message here — not even a reconstructed one: on a page that promises evidence, an invented message would be worse than none.