Check identifier 21011 — Status message
Check identifier 21011 · EDIFACT message type IFTSTA · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 21011 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| STATUSMITTEILUNG [ ] * | — | object[] | Must | — |
| positionsdaten [ ] * | — | object[] | Must | — |
| antwortstatus * 00010 | antwortstatus | string | X | — |
| antwortstatusCodeliste * 00020 | antwortstatusCodeliste | string | X | — |
| auftragsstatus * 00030 | Order status | Enum Auftragsstatus | X | — |
GESCHEITERT | — | — | X | — |
ERFOLGREICH | — | — | X | — |
LIEFERUNG_GEPLANT | — | — | X | — |
GEPLANT | — | — | X | — |
ZUGESTIMMT | — | — | X | — |
WIDERSPROCHEN | — | — | X | — |
STOERUNGSFREI | — | — | X | — |
GESTOERT | — | — | X | — |
FESTGESTELLTE_STOERUNG | — | — | X | — |
VERMUTETE_STOERUNG | — | — | X | — |
ABGELEHNT | — | — | X | — |
BEENDET | — | — | X | — |
ANTWORT_DRITTER | — | — | X | — |
BESTAETIGT | — | — | X | — |
UMGESETZT | — | — | X | — |
ENFG_STROMSPEICHER_UND_VERLUSTENERGIE | — | — | X | — |
ENFG_ELEKTRISCH_ANGETRIEBENE_WAERMEPUMPEN | — | — | X | — |
ENFG_UMLAGEERHEBUNG_BEI_ANLAGEN_ZUR_VERSTROMUNG_VON_KUPPELGASEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_GRUENEN_WASSERSTOFF | — | — | X | — |
ENFG_STROMKOSTENINTENSIVE_UNTERNEHMEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_WASSERSTOFF_IN_STROMKOSTENINTENSIVEN_UNTERNEHMEN | — | — | X | — |
ENFG_SCHIENENBAHNEN | — | — | X | — |
ENFG_ELEKTRISCHE_BETRIEBENE_BUSSEN_IM_LINIENVERKEHR | — | — | X | — |
ENFG_LANDSTROMANLAGEN | — | — | X | — |
AENDERUNG_DER_DATEN | — | — | X | — |
KEINE_AENDERUNG_DER_DATEN | — | — | X | — |
ZEITREIHE_AKZEPTIERT | — | — | X | — |
ZEITREIHE_NICHT_AKZEPTIERT | — | — | X | — |
| lokationsId * 00040 | lokationsId | string | X | — |
| mitteilungsnummer * 00050 | mitteilungsnummer | string | X | — |
| positionsnummer * 00060 | positionsnummer | integer | Must | — |
| vorgangsreferenznummer * 00070 | vorgangsreferenznummer | string | X | — |
| transaktionsdaten * | — | object | Must | — |
| dokumentennummer * 00080 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| nachrichtendatum * 00090 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00100 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00110 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00120 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00130 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00140 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00150 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 21011 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 IFTSTA00020 | Multimodal status report | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 18A00040 | Edition 2018 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z0900070 | WiM message(s) | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MR00120 | Message recipient | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33200160 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MS00170 | Document-/message sender or sender | — | X | — |
303900180 | MP-ID | — | X | — |
3055 900190 | GS1 | — | X | — |
3055 29300200 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33200210 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG14.CNI | — | — | Must | — |
149000220 | Transaction number | — | X | [911] |
| SG14.LOC | — | — | Must | — |
3227 17200230 | Reporting point | — | X | — |
322500240 | Identifier | — | X | [951] [505] |
| SG15.STS | — | — | Must | — |
9015 Z1000250 | MSB change under MsbG | — | X | — |
4405 Z1300260 | failed | — | X | — |
901300270 | Code of the check step | — | X | — |
1131 G_005500280 | Gas code list no. G_0055 | — | X | [493] |
1131 S_005700290 | Electricity code list no. S_0057 | — | X | [492] |
| SG15.RFF | — | — | Must | — |
1153 Z1300300 | Check identifier | — | X | — |
1154 2101100310 | WiM / status message (MSB/failure notification) from the NB to MSBN / MSBA / LF | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 ACW00320 | Reference number of a preceding message | — | X | — |
115400330 | Reference, identification | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 ADY00340 | Notification number | — | X | — |
115400350 | Reference, identification | — | X | — |
| UNT | — | — | Must | — |
007400360 | Number of segments in a message | — | X | — |
006200370 | Message reference number | — | X | — |
Conditions of this table
The free text of the 7 conditions referenced by the rows above. All conditions of the message type are listed in the condition index IFTSTA.
| Marker | Condition |
|---|---|
| [492] | if MP-ID in NAD+MR from division electricity |
| [493] | if MP-ID in NAD+MR from division gas |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [505] | Note: Use of the ID of the metering location |
| [911] | Format: Possible values: 1 to n, starting at 1 for each message and ascending consecutively |
| [931] | Format: ZZZ = +00 |
| [951] | Format: Metering point identifier |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Start of metering point operation | WiM electricity part 1 | Electricity | Step 8 |
| LF | LF | Start of metering point operation | WiM electricity part 1 | Electricity | Step 14 |
| LF | LF | Start of metering point operation | WiM electricity part 1 | Electricity | Step 15 |
| NB | NB | Start of metering point operation | AWH WiM gas 2.0 | Gas | Step 7 |
| NB | NB | Start of metering point operation | WiM electricity part 1 | Electricity | Step 8 |
| NB | NB | Start of metering point operation | WiM electricity part 1 | Electricity | Step 14 |
| NB | NB | Start of metering point operation | WiM electricity part 1 | Electricity | Step 15 |
| MSB | MSBA | Start of metering point operation | AWH WiM gas 2.0 | Gas | Step 7 |
| MSB | MSBA | Start of metering point operation | WiM electricity part 1 | Electricity | Step 8 |
| MSB | MSBA | Start of metering point operation | WiM electricity part 1 | Electricity | Step 14 |
| MSB | MSBA | Start of metering point operation | WiM electricity part 1 | Electricity | Step 15 |
| MSB | MSBN | Start of metering point operation | AWH WiM gas 2.0 | Gas | Step 7 |
| MSB | MSBN | Start of metering point operation | WiM electricity part 1 | Electricity | Step 8 |
| MSB | MSBN | Start of metering point operation | WiM electricity part 1 | Electricity | Step 14 |
| MSB | MSBN | Start of metering point operation | WiM electricity part 1 | Electricity | Step 15 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Status message |
| AHB | IFTSTA AHB |
| Response to check identifier | 21009 |
| Decision tree | E_0232 · E_2003 |
| Transmission channel | AS4 |
This check identifier is used in 5 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 1 | Start of metering point operation | NB → MSBN | Response to notification of the overall transaction |
| WiM electricity part 1 | Start of metering point operation | NB → MSBA | Information on failure of the assignment |
| WiM electricity part 1 | Start of metering point operation | NB → LF | Information on failure of the assignment |
| AWH WiM gas 2.0 | Start of metering point operation | NB → MSBN | Response to notification of the overall transaction |
| WiM gas | Ch. B 3.3 No. 8 | NB → MSBN | Confirmation of the failure of the assignment |
Individual entries from format version 202604
The check identifiers table of format version 202610 does not carry this entry: process step. It comes from version 202604. Version 202604 also carries this check identifier in contexts that the table of version 202610 does not know; they are included in the list above. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202610.
Transaction and responses
Role of this check identifier: response. Basis: the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 21009 | Status message | IFTSTA | explicit |
Weiterleitung (Dreieckskommunikation): Im Schritt davor steht 21011 mit derselben Senderichtung. Diese Nachricht antwortet dem Absender des Vorschritts also nicht, sie gibt weiter — deshalb steht hier kein Antwortsatz.
Reference field: This message carries none of the fields with which a response cites its request (anfragereferenznummer, auftragsReferenz, vorgangsreferenznummer, anfrageReferenz). The reference is therefore not in the data of this message: which message is meant follows only from the process, not from the message itself.
Response codes
Decision trees: G_0055 · S_0057 · E_0232 · E_2003.
The Prüfi table names 2 further trees across all rows of this check identifier. They bind it to a process, not to a row of its handbook — their codes therefore appear only on the respective tree page. No decision tree exists for G_0055, S_0057 in version 202610; its response codes are therefore not listed here.
Check identifiers of the same AHB table: No other check identifier of message type IFTSTA has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 49 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
No test case exists for this check identifier in the test data of the format version. There is therefore no example message here — not even a reconstructed one: on a page that promises evidence, an invented message would be worse than none.