Check identifier 21032 — Response to the quotation
Check identifier 21032 · EDIFACT message type IFTSTA · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 21032 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| STATUSMITTEILUNG [ ] * | — | object[] | Must | — |
| positionsdaten [ ] * | — | object[] | Must | — |
| angebotsnummer * 00010 | angebotsnummer | string | X | — |
| antwortstatus * 00020 | antwortstatus | string | X | — |
| antwortstatusCodeliste * 00030 | antwortstatusCodeliste | string | X | — |
| auftragsstatus * 00040 | Order status | Enum Auftragsstatus | X | — |
GESCHEITERT | — | — | X | — |
ERFOLGREICH | — | — | X | — |
LIEFERUNG_GEPLANT | — | — | X | — |
GEPLANT | — | — | X | — |
ZUGESTIMMT | — | — | X | — |
WIDERSPROCHEN | — | — | X | — |
STOERUNGSFREI | — | — | X | — |
GESTOERT | — | — | X | — |
FESTGESTELLTE_STOERUNG | — | — | X | — |
VERMUTETE_STOERUNG | — | — | X | — |
ABGELEHNT | — | — | X | — |
BEENDET | — | — | X | — |
ANTWORT_DRITTER | — | — | X | — |
BESTAETIGT | — | — | X | — |
UMGESETZT | — | — | X | — |
ENFG_STROMSPEICHER_UND_VERLUSTENERGIE | — | — | X | — |
ENFG_ELEKTRISCH_ANGETRIEBENE_WAERMEPUMPEN | — | — | X | — |
ENFG_UMLAGEERHEBUNG_BEI_ANLAGEN_ZUR_VERSTROMUNG_VON_KUPPELGASEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_GRUENEN_WASSERSTOFF | — | — | X | — |
ENFG_STROMKOSTENINTENSIVE_UNTERNEHMEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_WASSERSTOFF_IN_STROMKOSTENINTENSIVEN_UNTERNEHMEN | — | — | X | — |
ENFG_SCHIENENBAHNEN | — | — | X | — |
ENFG_ELEKTRISCHE_BETRIEBENE_BUSSEN_IM_LINIENVERKEHR | — | — | X | — |
ENFG_LANDSTROMANLAGEN | — | — | X | — |
AENDERUNG_DER_DATEN | — | — | X | — |
KEINE_AENDERUNG_DER_DATEN | — | — | X | — |
ZEITREIHE_AKZEPTIERT | — | — | X | — |
ZEITREIHE_NICHT_AKZEPTIERT | — | — | X | — |
| lokationsId * 00050 | lokationsId | string | X | — |
| positionsnummer * 00060 | positionsnummer | integer | Must | — |
| transaktionsdaten * | — | object | Must | — |
| dokumentennummer * 00070 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| nachrichtendatum * 00080 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00090 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00100 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00110 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00120 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00130 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00140 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 21032 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 IFTSTA00020 | Multimodal status report | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 18A00040 | Edition 2018 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z0900070 | WiM message(s) | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MR00120 | Message recipient | — | X | — |
303900130 | MP-ID | — | X | [27] |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MS00160 | Document-/message sender or sender | — | X | — |
303900170 | MP-ID | — | X | [27] |
3055 900180 | GS1 | — | X | — |
3055 29300190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG14.CNI | — | — | Must | — |
149000200 | Transaction number | — | X | [911] |
| SG14.LOC | — | — | Must | — |
3227 17200210 | Reporting point | — | X | — |
322500220 | Identifier | — | X | [950] [506] |
| SG15.STS | — | — | Must | — |
9015 Z2000230 | Status of the referenced document | — | X | — |
4405 Z3200240 | rejected | — | X | — |
901300250 | Code of the check step | — | X | — |
1131 E_020500260 | EBD no. E_0205 | — | X | — |
1131 E_020800270 | EBD no. E_0208 | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 Z1300280 | Check identifier | — | X | — |
1154 2103200290 | WiM / offer rejection (LF to MSB) | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 AAG00300 | Quotation number | — | X | — |
115400310 | Document-/transaction number of the reference message | — | X | [501] |
| UNT | — | — | Must | — |
007400320 | Number of segments in a message | — | X | — |
006200330 | Message reference number | — | X | — |
Conditions of this table
The free text of the 7 conditions referenced by the rows above. All conditions of the message type are listed in the condition index IFTSTA.
| Marker | Condition |
|---|---|
| [27] | Only MP-ID from the electricity division |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [501] | Note: From QUOTES BGM DE1004 |
| [506] | Note: Use of the ID of the market location |
| [911] | Format: Possible values: 1 to n, starting at 1 for each message and ascending consecutively |
| [931] | Format: ZZZ = +00 |
| [950] | Format: market location ID |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Request for invoice processing of the metering point operation via the LF by the LF | WiM electricity part 1 | Electricity | Step 3 |
| LF | LF | Quotation for invoice processing of the metering point operation via the LF by the MSB | WiM electricity part 1 | Electricity | Step 2 |
| MSB | MSB-MALO | Request for invoice processing of the metering point operation via the LF by the LF | WiM electricity part 1 | Electricity | Step 3 |
| MSB | MSB-MALO | Quotation for invoice processing of the metering point operation via the LF by the MSB | WiM electricity part 1 | Electricity | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response to the quotation |
| AHB | IFTSTA AHB |
| Decision tree | E_0205 · E_0208 |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 1 | Quotation for invoice processing of metering point operation via the LF by the MSB | LF → MSB (corresponds to MSB on the market location object) | Response to the quotation |
| WiM electricity part 1 | Request for invoice processing of metering point operation via the LF by the LF | LF → MSB (corresponds to MSB on the market location object) | Response quotation |
Transaction and responses
Role of this check identifier: response. Basis: the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 21033 | Rejection of the request | IFTSTA | from the step sequence |
Reference field: This message carries none of the fields with which a response cites its request (anfragereferenznummer, auftragsReferenz, vorgangsreferenznummer, anfrageReferenz). The reference is therefore not in the data of this message: which message is meant follows only from the process, not from the message itself.
Response codes
Decision tree E_0205 — named in: AHB STS DE1131 and Prüfi table.
| Response code | Cluster | Meaning | Outputs |
|---|---|---|---|
| A01 | — | No valid contract | 1 |
| A02 | — | Equipped exclusively with kME | 1 |
| A03 | — | Contractual relationship with third parties does not permit billing of metering point operation | 1 |
| A04 | — | Contractual relationship with third parties does not permit the start date | 1 |
| A05 | — | No price sheet available | 1 |
| A06 | — | Quotation items deviate from the contractual relationship | 1 |
Decision tree E_0208 — named in: AHB STS DE1131 and Prüfi table.
| Response code | Cluster | Meaning | Outputs |
|---|---|---|---|
| A01 | — | Contractual relationship with third parties does not permit the start date. | 1 |
| A02 | — | No price sheet available | 1 |
| A03 | — | Quotation items deviate from the contractual relationship | 1 |
Check identifiers of the same AHB table: No other check identifier of message type IFTSTA has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 44 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
No test case exists for this check identifier in the test data of the format version. There is therefore no example message here — not even a reconstructed one: on a page that promises evidence, an invented message would be worse than none.