Check identifier 21042 — Order placement (WiM)
Check identifier 21042 · EDIFACT message type IFTSTA · Format version 202604
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 21042 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 IFTSTA00020 | Multimodal status report | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 18A00040 | Edition 2018 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 2.0g00060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z0900070 | WiM message(s) | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/ message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MR00120 | Message recipient | — | X | — |
303900130 | MP-ID | — | X | [27] |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MS00160 | Document-/ message sender or sender | — | X | — |
303900170 | MP-ID | — | X | [27] |
3055 900180 | GS1 | — | X | — |
3055 29300190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.CTA | — | — | Must | — |
3139 IC00200 | Information contact | — | X | — |
341200210 | Contact | — | X | — |
| SG2.COM | — | — | Must | — |
314800220 | Number / email address | — | X | (([939][146]) ∨ ([940] [147])) ∧ [534] |
3155 EM00230 | — | X | [1P0..1] | |
3155 FX00240 | Fax number | — | X | [1P0..1] |
3155 TE00250 | Telephone | — | X | [1P0..1] |
3155 AJ00260 | further telephone | — | X | [1P0..1] |
3155 AL00270 | Mobile phone | — | X | [1P0..1] |
| SG14.CNI | — | — | Must | — |
149000280 | Transaction number | — | X | [911] |
| SG15.STS | — | — | Must | — |
9015 Z2100290 | Order placement | — | X | — |
4405 10500300 | ended | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 Z1300310 | Check identifier | — | X | — |
1154 2104200320 | WiM / Implementation status of the order placement | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 AGI00330 | Application number | — | X | — |
115400340 | Reference, identification | — | X | [519] |
| SG15.DTM | — | — | Must | — |
2005 9300350 | Contract end date | — | X | — |
238000360 | Date or time or time span, value | — | X | [UB1] |
2379 30300370 | CCYYMMDDHHMMZZZ | — | X | — |
| UNT | — | — | Must | — |
007400380 | Number of segments in a message | — | X | — |
006200390 | Message reference number | — | X | — |
Conditions of this table
The free text of the 12 conditions referenced by the rows above. All conditions of the message type are listed in the condition index IFTSTA.
| Marker | Condition |
|---|---|
| [27] | Only MP-ID from the electricity division |
| [146] | If code EM is present in DE3155 in the same COM |
| [147] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [519] | Note: From ORDERS BGM DE1004 |
| [534] | Note: Only one piece of information may be transmitted in DE3148 |
| [911] | Format: Possible values: 1 to n, starting at 1 for each message and ascending consecutively |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are MSB and ESA.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| MSB | MSB | Termination of the transmission of values to ESA by MSB | WiM electricity part 2 | Electricity | Step 1 |
| ESA | ESA | Termination of the transmission of values to ESA by MSB | WiM electricity part 2 | Electricity | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Order placement (WiM) |
| AHB | IFTSTA AHB |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 2 | Termination of the transmission of values to ESA by MSB | MSB → ESA | Information about the termination of the transmission of values |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 52 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.