Check identifier 21030 — iMS initial install. consent
Check identifier 21030 · EDIFACT message type IFTSTA · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 21030 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| STATUSMITTEILUNG [ ] * | — | object[] | Must | — |
| positionsdaten [ ] * | — | object[] | Must | — |
| antwortstatus * 00010 | antwortstatus | string | X | — |
| antwortstatusCodeliste * 00020 | antwortstatusCodeliste | string | X | — |
| auftragsstatus * 00030 | Order status | Enum Auftragsstatus | X | — |
GESCHEITERT | — | — | X | — |
ERFOLGREICH | — | — | X | — |
LIEFERUNG_GEPLANT | — | — | X | — |
GEPLANT | — | — | X | — |
ZUGESTIMMT | — | — | X | — |
WIDERSPROCHEN | — | — | X | — |
STOERUNGSFREI | — | — | X | — |
GESTOERT | — | — | X | — |
FESTGESTELLTE_STOERUNG | — | — | X | — |
VERMUTETE_STOERUNG | — | — | X | — |
ABGELEHNT | — | — | X | — |
BEENDET | — | — | X | — |
ANTWORT_DRITTER | — | — | X | — |
BESTAETIGT | — | — | X | — |
UMGESETZT | — | — | X | — |
ENFG_STROMSPEICHER_UND_VERLUSTENERGIE | — | — | X | — |
ENFG_ELEKTRISCH_ANGETRIEBENE_WAERMEPUMPEN | — | — | X | — |
ENFG_UMLAGEERHEBUNG_BEI_ANLAGEN_ZUR_VERSTROMUNG_VON_KUPPELGASEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_GRUENEN_WASSERSTOFF | — | — | X | — |
ENFG_STROMKOSTENINTENSIVE_UNTERNEHMEN | — | — | X | — |
ENFG_HERSTELLUNG_VON_WASSERSTOFF_IN_STROMKOSTENINTENSIVEN_UNTERNEHMEN | — | — | X | — |
ENFG_SCHIENENBAHNEN | — | — | X | — |
ENFG_ELEKTRISCHE_BETRIEBENE_BUSSEN_IM_LINIENVERKEHR | — | — | X | — |
ENFG_LANDSTROMANLAGEN | — | — | X | — |
AENDERUNG_DER_DATEN | — | — | X | — |
KEINE_AENDERUNG_DER_DATEN | — | — | X | — |
ZEITREIHE_AKZEPTIERT | — | — | X | — |
ZEITREIHE_NICHT_AKZEPTIERT | — | — | X | — |
| lieferdatum * 00040 | lieferdatum | string | X | — |
| lokationsId * 00050 | lokationsId | string | X | — |
| mitteilungsnummer * 00060 | mitteilungsnummer | string | X | — |
| positionsnummer * 00070 | positionsnummer | integer | Must | — |
| vorgangsreferenznummer * 00080 | vorgangsreferenznummer | string | X | — |
| transaktionsdaten * | — | object | Must | — |
| dokumentennummer * 00090 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| nachrichtendatum * 00100 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00110 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00120 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00130 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00140 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00150 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00160 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 21030 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 IFTSTA00020 | Multimodal status report | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 18A00040 | Edition 2018 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z0900070 | WiM message(s) | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MR00120 | Message recipient | — | X | — |
303900130 | MP-ID | — | X | [27] |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG1.NAD | — | — | Must | — |
3035 MS00160 | Document-/message sender or sender | — | X | — |
303900170 | MP-ID | — | X | [27] |
3055 900180 | GS1 | — | X | — |
3055 29300190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG14.CNI | — | — | Must | — |
149000200 | Transaction number | — | X | [911] |
| SG14.LOC | — | — | Must | — |
3227 17200210 | Reporting point | — | X | — |
322500220 | Identifier | — | X | [951] [505] |
| SG15.STS | — | — | Must | — |
9015 Z1900230 | Initial installation iMS | — | X | — |
4405 Z3000240 | agreed | — | X | [503] |
901300250 | Code of the check step | — | X | [48] |
1131 E_023300260 | EBD no. E_0233 | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 Z1300270 | Check identifier | — | X | — |
1154 2103000280 | WiM / Consent iMS initial installation | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 ACW00290 | Reference number of a preceding message | — | X | — |
115400300 | Reference, identification | — | X | — |
| SG15.RFF | — | — | Must | — |
1153 ADY00310 | Notification number | — | X | — |
115400320 | Reference, identification | — | X | — |
| SG15.DTM | — | — | Must | — |
2005 7600330 | Delivery date/time, scheduled | — | X | — |
238000340 | Date or time or time span, value | — | X | [496] |
2379 10200350 | CCYYMMDD | — | X | — |
| UNT | — | — | Must | — |
007400360 | Number of segments in a message | — | X | — |
006200370 | Message reference number | — | X | — |
Conditions of this table
The free text of the 9 conditions referenced by the rows above. All conditions of the message type are listed in the condition index IFTSTA.
| Marker | Condition |
|---|---|
| [27] | Only MP-ID from the electricity division |
| [48] | Only codes from the EBD cluster "consent" are possible. |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [496] | The point in time must be > the value in DE2380 of DTM+137 |
| [503] | Note: Self-installation of a iMS or a mME is waived |
| [505] | Note: Use of the ID of the metering location |
| [911] | Format: Possible values: 1 to n, starting at 1 for each message and ascending consecutively |
| [931] | Format: ZZZ = +00 |
| [951] | Format: Metering point identifier |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Initial installation of a iMS in an existing metering location | WiM electricity part 1 | Electricity | Step 2 |
| NB | NB | Initial installation of a iMS in an existing metering location | WiM electricity part 1 | Electricity | Step 2 |
| MSB | GMSB | Initial installation of a iMS in an existing metering location | WiM electricity part 1 | Electricity | Step 2 |
| MSB | WMSB | Initial installation of a iMS in an existing metering location | WiM electricity part 1 | Electricity | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | iMS initial install. status |
| AHB | IFTSTA AHB |
| Decision tree | E_0233 |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 1 | Initial installation of a iMS in an existing metering location | MSB (corresponds to wMSB on the object metering location) → MSB (corresponds to gMSB on the object metering location) | Information on grandfathering / own installation iMS |
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.
Responses: No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.
Check identifiers of the same AHB table: No other check identifier of message type IFTSTA has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 50 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
No test case exists for this check identifier in the test data of the format version. There is therefore no example message here — not even a reconstructed one: on a page that promises evidence, an invented message would be worse than none.