Check identifier 44042 — Registration MSB
Check identifier 44042 · EDIFACT message type UTILMD_GAS · Format version 202604
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 44042 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 G1.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0100070 | Registrations | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/ message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/ message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 33200150 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00160 | Information contact | — | X | — |
341200170 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800180 | Number / address | — | X | — |
3155 EM00190 | Electronic mail | — | X | [1P0..1] |
3155 FX00200 | Fax number | — | X | [1P0..1] |
3155 TE00210 | Telephone | — | X | [1P0..1] |
3155 AJ00220 | further telephone | — | X | [1P0..1] |
3155 AL00230 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00240 | Message recipient | — | X | — |
303900250 | MP-ID | — | X | — |
3055 900260 | GS1 | — | X | — |
3055 33200270 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400280 | Transaction | — | X | — |
740200290 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 7600300 | Delivery date/time, scheduled | — | X | — |
238000310 | Date or time or time span, value | — | X | [UB2] |
2379 30300320 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.STS | — | — | Must | [2061] |
9015 700330 | Transaction reason | — | X | — |
9013 E0100340 | Move-in/move-out (relocation) | — | X | — |
9013 E0200350 | Move-in to creation | — | X | — |
9013 E0300360 | Change | — | X | — |
| SG4.AGR | — | — | May | — |
7431 900370 | Contract | — | X | — |
7433 Z0400380 | Contract between contractor and MSB | — | X | [1P0..1] |
7433 Z0600390 | Contract termination exists | — | X | [1P0..1] |
| SG5.LOC | — | — | Must | — |
3227 17200400 | Reporting point | — | X | — |
322500410 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300420 | Check identifier | — | X | — |
1154 4404200430 | WiM gas / registration MSB | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0300440 | Metering device data | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1300450 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3000460 | Device number | — | X | — |
711000470 | Device number | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0700480 | Customer of the MSB | — | X | — |
303600490 | Name | — | X | — |
3045 Z0100500 | Structure of person names | — | X | — |
3045 Z0200510 | Structure of the company name | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0800520 | Correspondence address of the customer of the MSB | — | X | — |
303600530 | Name | — | X | — |
3045 Z0100540 | Structure of person names | — | X | — |
3045 Z0200550 | Structure of the company name | — | X | — |
304200560 | Street and house number or PO box | — | X | — |
316400570 | City | — | X | — |
325100580 | Postal code | — | — | M [268] S [166] |
320700590 | Country name, code | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0300600 | Metering location address | — | X | — |
312400610 | Additional information for identification | — | — | — |
304200620 | Street and house number or PO box | — | — | S [166] M [212] |
316400630 | City | — | X | — |
325100640 | Postal code | — | X | — |
320700650 | Country name, code | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0500660 | Name and address for the meter reading card | — | X | — |
303600670 | Name | — | X | — |
3045 Z0100680 | Structure of person names | — | X | — |
3045 Z0200690 | Structure of the company name | — | X | — |
304200700 | Street and house number or PO box | — | X | — |
316400710 | City | — | X | — |
325100720 | Postal code | — | — | M [268] S [166] |
320700730 | Country name, code | — | X | — |
| SG12.RFF | — | — | May | — |
1153 Z1900740 | Metering location | — | X | — |
115400750 | ID of a metering location | — | X | [951] |
| UNT | — | — | Must | — |
007400760 | Number of segments in a message | — | X | — |
006200770 | Message reference number | — | X | — |
Conditions of this table
The free text of the 9 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDG.
| Marker | Condition |
|---|---|
| [166] | If present |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [268] | If an "X" is listed for the code in DE3207 in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [931] | Format: ZZZ = +00 |
| [951] | Format: Metering point identifier |
| [2061] | Segment or segment group must be specified exactly once per SG4 IDE (transaction) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [UB2] | ([931] ∧ [934] [490]) ⊻ ([931] ∧ [935] [491]) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | NB | Start of metering point operation | AWH WiM gas 2.0 | Gas | Step 1 |
| MSB | MSBA | Start of metering point operation | AWH WiM gas 2.0 | Gas | Step 1 |
| MSB | MSBN | Start of metering point operation | AWH WiM gas 2.0 | Gas | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Registration MSB |
| AHB | UTILMD AHB gas |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM gas | Ch. B 3.3 No. 1 | MSBN → NB | Registration |
| AWH WiM gas 2.0 | Start of metering point operation | MSBN → NB | Registration |
Further relationships from format version 202610
Version 202610 also carries this check identifier in contexts that the table of version 202604 does not know; they are included in the list above. Everything else on this page — use case, rulebook and communication direction — comes from the page's own version. Before adopting it into an implementation specification, check whether what is stated applies to 202604.
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 99 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.