Check identifier 44051 — End MSB
Check identifier 44051 · EDIFACT message type UTILMD_GAS · Format version 202610
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 44051 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 G1.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0200070 | Deregistrations | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 33200150 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00160 | Message recipient | — | X | — |
303900170 | MP-ID | — | X | — |
3055 900180 | GS1 | — | X | — |
3055 33200190 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400200 | Transaction | — | X | — |
740200210 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | [7] ∧ [577] |
2005 9200220 | Contract start date | — | X | — |
238000230 | Date or time or time span, value | — | X | [UB2] |
2379 30300240 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.DTM | — | — | Must | [11] |
2005 9300250 | Contract end date | — | X | — |
238000260 | Date or time or time span, value | — | X | [UB2] |
2379 30300270 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.STS | — | — | Must | [2061] |
9015 700280 | Transaction reason | — | X | — |
9013 E0100290 | Move-in/move-out (relocation) | — | X | — |
9013 E0300300 | Change | — | X | — |
9013 Z3300310 | Move-out due to decommissioning | — | X | — |
9013 ZG900320 | Revocation of a future assignment due to the customer moving out | — | X | — |
9013 ZH100330 | Revocation of a future assignment due to decommissioning | — | X | — |
9013 ZH200340 | Revocation of a future assignment due to a revoked contractual relationship | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 17200350 | Reporting point | — | X | — |
322500360 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300370 | Check identifier | — | X | — |
1154 4405100380 | WiM gas / end MSB | — | X | — |
| UNT | — | — | Must | — |
007400390 | Number of segments in a message | — | X | — |
006200400 | Message reference number | — | X | — |
Conditions of this table
The free text of the 8 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDG.
| Marker | Condition |
|---|---|
| [7] | If SG4 STS+7++ZG9/ZH1/ZH2 (transaction reason: cancellation of a future assignment due to move-out of the customer / -due to decommissioning / -due to cancelled contractual relationship) is present |
| [11] | If SG4 STS+7++ZG9/ZH1/ZH2 (transaction reason: cancellation of a future assignment due to move-out of the customer / -due to decommissioning / -due to cancelled contractual relationship) is not present |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [577] | Note: Filled with the start date originally confirmed by the NB |
| [931] | Format: ZZZ = +00 |
| [951] | Format: Metering point identifier |
| [2061] | Segment or segment group must be specified exactly once per SG4 IDE (transaction) |
| [UB2] | ([931] ∧ [934] [490]) ⊻ ([931] ∧ [935] [491]) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | NB | End of metering point operation from the MSB to NB | AWH WiM gas 2.0 | Gas | Step 1 |
| MSB | GMSB | End of metering point operation from the MSB to NB | AWH WiM gas 2.0 | Gas | Step 1 |
| MSB | MSBA | End of metering point operation from the MSB to NB | AWH WiM gas 2.0 | Gas | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | End of MSB |
| AHB | UTILMD AHB gas |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| AWH WiM gas 2.0 | End of metering point operation from MSB to NB | MSBA → NB | Deregistration |
| WiM gas | Ch. B 4.3 No. 1 | MSBA → NB | Deregistration |
Individual entries from format version 202604
The check identifiers table of format version 202610 does not carry this entry: process step. It comes from version 202604. Version 202604 also carries this check identifier in contexts that the table of version 202610 does not know; they are included in the list above. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202610.
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 52 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.