Check identifier 44002 — Confirmation of registration
Check identifier 44002 · EDIFACT message type UTILMD_GAS · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 44002 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| BILANZIERUNG [ ] * | — | object[] | Must | — |
| bilanzierungsbeginn 00010 | Inclusive start of the balancing | string (date-time) | X | — |
| bilanzierungsende 00020 | Exclusive end of balancing | string (date-time) | X | — |
| fallgruppenzuordnung 00030 | Case group assignment (for gas RLM) | Enum Fallgruppenzuordnung | Must | — |
GABI_RLMmT | — | — | Must | — |
GABI_RLMoT | — | — | Must | — |
GABI_RLMNEV | — | — | Must | — |
| prognosegrundlage * 00040 | Forecast basis | Enum Prognosegrundlage | Must | — |
WERTE | — | — | Must | — |
PROFILE | — | — | Must | — |
| bilanzkreise [ ] | — | object[] | May | — |
| bezeichnung 00050 | External designation | string | X | — |
| jahresverbrauchsprognose | — | object | May | — |
| einheit 00060 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 00070 | Value | number (float) | X | — |
| kundenwert | — | object | May | — |
| wert 00080 | Value | number (float) | X | — |
| lastprofile [ ] | — | object[] | May | — |
| bezeichnung 00090 | Designation of the profile | string | Must | — |
| herausgeber 00100 | Issuer of the load profile | string | Must | — |
| verfahren 00110 | Profiling method | Enum Profilverfahren | X | — |
SYNTHETISCH | — | — | X | — |
ANALYTISCH | — | — | X | — |
| tagesparameter | — | object | May | — |
| dienstanbieter 00120 | dienstanbieter | string | Must | — |
| herausgeber 00130 | Herausgeber | Enum Herausgeber | Must | — |
NB | — | — | Must | — |
BDEW | — | — | Must | — |
TUM | — | — | Must | — |
| klimazone 00140 | klimazone | string | Must | — |
| temperaturmessstelle 00150 | temperaturmessstelle | string | Must | — |
| ENERGIELIEFERVERTRAG [ ] * | — | object[] | Must | — |
| korrespondenzpartner * | — | object | Must | — |
| anrede 00160 | The form of address for the GePa, e.g. Mr. | string | X | — |
| gewerbekennzeichnung 00170 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | X | — |
| name1 * 00180 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00190 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00200 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00210 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 00220 | House number and supplement | string | X | — |
| landescode 00230 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00240 | City | string | X | — |
| ortsteil 00250 | District | string | X | — |
| postfach 00260 | PO box | string | X | — |
| postleitzahl 00270 | Postal code | string | X | — |
| strasse 00280 | Street | string | X | — |
| vertragskonditionen * | — | object | Must | — |
| abrechnungsintervall * 00290 | abrechnungsintervall | integer | X | — |
| vertragspartner2 [ ] * | — | object[] | Must | — |
| anrede 00300 | The form of address for the GePa, e.g. Mr. | string | X | — |
| gewerbekennzeichnung 00310 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | X | — |
| name1 * 00320 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00330 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00340 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00350 | name4 | string | X | — |
| externeReferenzen [ ] | — | object[] | May | — |
| exRefName 00360 | Name of the external reference (e.g. "hochfrequenz integration services") | string | X | — |
Kundennummer beim Lieferanten | — | — | X | — |
Kundennummer beim Altlieferanten | — | — | X | — |
| exRefWert 00370 | Value of the external reference (e.g. "123456"; "4711") | string | X | — |
| MARKTLOKATION [ ] * | — | object[] | Must | — |
| marktgebiet * 00380 | for EDIFACT mapping | string | X | — |
| marktlokationsId * 00390 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| netzebene * 00400 | Grid level at which the energy is drawn. For electricity, the voltage level of the supply; for gas, the pressure level. Example electricity: low voltage Example gas: low pressure. | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| lokationsadresse | — | object | May | — |
| hausnummer 00410 | House number and supplement | string | X | — |
| landescode 00420 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00430 | City | string | X | — |
| ortsteil 00440 | District | string | X | — |
| postfach 00450 | PO box | string | X | — |
| postleitzahl 00460 | Postal code | string | X | — |
| strasse 00470 | Street | string | X | — |
| zusatzInformation | — | object | May | — |
| zusatz1 00480 | Address supplement 1 | string | X | — |
| zusatz2 00490 | Address supplement 2 | string | X | — |
| zusatz3 00500 | Address supplement 3 | string | X | — |
| zusatz4 00510 | Address supplement 4 | string | X | — |
| zusatz5 00520 | Address supplement 5 | string | X | — |
| zaehlwerke [ ] * | — | object[] | Must | — |
| obisKennzahl * 00530 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| wertegranularitaet 00540 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| konzessionsabgabe | — | object | May | — |
| kategorie 00550 | Category | string | Must | — |
| kosten 00560 | Costs | number (float) | Must | — |
| satz 00570 | Type of concession levy | Enum AbgabeArt | Must | — |
KAS | — | — | Must | — |
SA | — | — | Must | — |
SAS | — | — | Must | — |
TA | — | — | Must | — |
TAS | — | — | Must | — |
TK | — | — | Must | — |
TKS | — | — | Must | — |
TS | — | — | Must | — |
TSS | — | — | Must | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| gasqualitaet 00580 | gasqualitaet for EDIFACT mapping | Enum Gasqualitaet | Must | — |
H_GAS | — | — | Must | — |
L_GAS | — | — | Must | — |
| messlokationsId * 00590 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| ablesekartenempfaenger * | — | object | Must | — |
| anrede 00600 | The form of address for the GePa, e.g. Mr. | string | X | — |
| gewerbekennzeichnung 00610 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | X | — |
| name1 * 00620 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00630 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00640 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00650 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 00660 | House number and supplement | string | X | — |
| landescode 00670 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00680 | City | string | X | — |
| ortsteil 00690 | District | string | X | — |
| postfach 00700 | PO box | string | X | — |
| postleitzahl 00710 | Postal code | string | X | — |
| strasse 00720 | Street | string | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00730 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| rollencodenummer 00740 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00750 | weiterverpflichtet | boolean | X | — |
| NETZNUTZUNGSVERTRAG [ ] * | — | object[] | Must | — |
| gemeinderabatt * 00760 | municipal discount for EDIFACT mapping. | integer | X | — |
| vertragsbeginn 00770 | Specifies when the contract begins. | string (date-time) | X | — |
| vertragsende 00780 | Specifies when the contract (is expected to) end or was ended. | string (date-time) | X | — |
| vertragskonditionen * | — | object | Must | — |
| haushaltskunde * 00790 | haushaltskunde | boolean | Must | — |
| naechstenetznutzungsabrechnung * 00800 | naechstenetznutzungsabrechnung | string | X | — |
| netznutzungsabrechnungIntervall * 00810 | netznutzungsabrechnungIntervall | integer | X | [504] |
| netznutzungsabrechnungsvariante * 00820 | Grid usage settlement variant | Enum Netznutzungsabrechnungsvariante | X | — |
ARBEITSPREIS_GRUNDPREIS | — | — | X | — |
ARBEITSPREIS_LEISTUNGSPREIS | — | — | X | — |
| netznutzungsvertrag * 00830 | Grid usage contract | Enum Netznutzungsvertrag | X | — |
KUNDEN_NB | — | — | X | — |
LIEFERANTEN_NB | — | — | X | — |
| netznutzungszahler * 00840 | Grid usage payer | Enum Netznutzungszahler | X | — |
KUNDE | — | — | X | — |
LIEFERANT | — | — | X | — |
| netznutzungsabrechnung * | — | object | Must | — |
| abrechnungsZeitraum * 00850 | abrechnungsZeitraum | string | X | — |
| ZAEHLER [ ] | — | object[] | May | — |
| messlokationsId 00860 | messlokationsId | string | X | — |
| messwerterfassung 00870 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| zaehlergroesse 00880 | Meter size | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlernummer 00890 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 00900 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 00910 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 00920 | The number printed on the device, which is assigned by the MSB. | string | X | — |
| geraeteeigenschaften | — | object | May | — |
| geraetemerkmal 00930 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlwerke [ ] | — | object[] | May | — |
| bezeichnung 00940 | Additional designation, e.g. Zählwerk_Wirkarbeit. | string | Must | — |
| nachkommastelle 00950 | nachkommastelle | integer | Must | — |
| obisKennzahl 00960 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| vorkommastelle 00970 | vorkommastelle | integer | Must | — |
| wertegranularitaet 00980 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer * 00990 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| antwortstatus * 01000 | Response status / STS+E01 | string | X | — |
| antwortstatusCodeliste * 01010 | Response status code list / STS+E01 | string | X | — |
| dokumentennummer * 01020 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| freitext 01030 | Free text / FTX+ACB | string | X | — |
| kategorie * 01040 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 01050 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 01060 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 01070 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 01080 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| transaktionsgrundergaenzungBefristeteAnmeldung 01090 | Supplement to the transaction reason for temporary registrations/deregistrations / UTILMD STS+7++E01+ZW4+### | string | X | — |
| vertragsbeginn 01100 | Contract start date / DTM+92 | string (date-time) | X | — |
| vertragsende 01110 | Contract end date / DTM+93 | string (date-time) | X | — |
| vorgangsnummer * 01120 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 01130 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 01140 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 01150 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 01160 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 44002 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 G1.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0100070 | Registrations | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 33200150 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00160 | Message recipient | — | X | — |
303900170 | MP-ID | — | X | — |
3055 900180 | GS1 | — | X | — |
3055 33200190 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400200 | Transaction | — | X | — |
740200210 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 9200220 | Contract start date | — | X | — |
238000230 | Date or time or time span, value | — | X | [UB2] |
2379 30300240 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.DTM | — | — | Must | [10] |
2005 9300250 | Contract end date | — | X | — |
238000260 | Date or time or time span, value | — | X | [UB2] |
2379 30300270 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.DTM | — | — | Must | [18] Should [28] ∧ [29] |
2005 15800280 | Start of balancing | — | X | — |
238000290 | Date or time or time span, value | — | X | [UB2] |
2379 30300300 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.DTM | — | — | Must | [28] ∧ [64] |
2005 15900310 | End of balancing | — | X | — |
238000320 | Date or time or time span, value | — | X | [UB2] |
2379 30300330 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.STS | — | — | Must | [2061] |
9015 700340 | Transaction reason | — | X | — |
9013 E0100350 | Move-in/move-out (relocation) | — | X | — |
9013 E0200360 | Move-in to creation | — | X | — |
9013 E0300370 | Change | — | X | — |
9013 ZD200380 | Start of supply and deregistration from substitute supply | — | X | — |
| SG4.STS | — | — | Should | [37] |
9015 Z1700390 | Transaction reason supplement for temporary registration | — | X | — |
9013 E0100400 | Move-in/move-out (relocation) | — | X | — |
9013 E0300410 | Change | — | X | — |
| SG4.STS | — | — | Must | [249] |
9015 E0100420 | Status of the response | — | X | — |
901300430 | Code of the check step | — | X | — |
1131 G_001200440 | Gas code list no. G_0012 | — | X | — |
| SG4.FTX | — | — | May | — |
4451 ACB00450 | Additional information (for general notes) | — | X | — |
444000460 | Text for general information | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 17200470 | Reporting point | — | X | — |
322500480 | Identifier | — | X | [953] |
| SG6.RFF | — | — | Must | — |
1153 Z1300490 | Check identifier | — | X | — |
1154 4400200500 | GeLi Gas / Confirmation registration | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00510 | Transaction reference number | — | X | — |
115400520 | Transaction number | — | X | — |
| SG6.RFF | — | — | Must | [636] |
1153 Z1800530 | Market location | — | X | — |
115400540 | ID of the market location | — | X | [950] |
| SG6.DTM | — | — | Must | — |
2005 Z2000550 | Billing interval of the LF | — | X | — |
238000560 | Date or time or time span, value | — | X | — |
2379 80200570 | Month | — | X | — |
| SG6.DTM | — | — | Must | — |
2005 Z2100580 | Grid usage settlement date | — | X | — |
238000590 | Date or time or time span, value | — | X | — |
2379 10600600 | MMDD | — | X | — |
2379 10400610 | MMWW-MMWW | — | X | — |
| SG6.DTM | — | — | Must | [230] |
2005 Z0900620 | Next grid usage settlement | — | X | — |
238000630 | Date or time or time span, value | — | X | — |
2379 60200640 | CCYY | — | X | — |
| SG6.DTM | — | — | Must | — |
2005 Z2200650 | Grid usage settlement or feed-in remuneration interval of the NB | — | X | [504] |
238000660 | Date or time or time span, value | — | X | — |
2379 80200670 | Month | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0100680 | Data of the market location | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 3100690 | Estimated annual quantity total | — | X | — |
606000700 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH00710 | Kilowatt hour | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Y0200720 | Customer value | — | X | — |
606000730 | Quantity specification | — | X | [902] ∧ [907] |
6411 KWH00740 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1900750 | Balancing group | — | X | — |
703700760 | Balancing group | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2100770 | Market area | — | X | — |
703700780 | Market area | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Y0100790 | Pressure level of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Y0100800 | High pressure | — | X | — |
7111 Y0200810 | Medium pressure | — | X | — |
7111 Y0300820 | Low pressure | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZC000830 | Forecast based on values | — | X | — |
7037 ZA600840 | Forecast based on profiles | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z1500850 | Household customer pursuant to EnWG | — | X | — |
7037 Z1800860 | Not a household customer under EnWG | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z1700870 | Case group assignment according to GABi Gas | — | X | — |
1131 GABi-RLMNEV00880 | Nomination replacement procedure - exit (note: this code may only be used for delivery months before 01.10.2016) | — | X | — |
1131 GABi-RLMmT00890 | RLM customer on daily regime - Exit | — | X | — |
1131 GABi-RLMoT00900 | RLM customer on hourly regime - Exit | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z8800910 | Grid usage | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z7400920 | Grid usage contract | — | X | — |
7110 Z0800930 | Direct contract between customer and NB | — | X | — |
7110 Z0900940 | Contract between supplier and NB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z7300950 | Payment of grid usage | — | X | — |
7110 Z1000960 | Customer | — | X | [216] |
7110 Z1100970 | Supplier | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZB100980 | Grid usage settlement variant | — | X | — |
7110 Z1400990 | Energy price/basic price | — | X | — |
7110 Z1501000 | Energy price/demand price | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0201010 | OBIS data of the market location | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 501020 | Product identification | — | X | — |
714001030 | OBIS code of the market location | — | X | [315] |
7143 SRW01040 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401050 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD901060 | Annually | — | X | — |
7111 ZE801070 | Semi-annual | — | X | — |
7111 ZE901080 | Quarterly | — | X | — |
7111 ZB701090 | Monthly | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0701100 | Concession levy data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1001110 | OBIS code | — | X | — |
115401120 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z0801130 | Concession levy | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 KAS01140 | for all special provisions under concession agreements that are not integrated into the structure of the KAV | — | X | — |
7111 SA01150 | Special contract customers < 1 kV under § 2 (7) and > 1 kV, price under § 2 (3) (for electricity 0.11 ct/kWh and for gas 0.03 ct/kWh) | — | X | — |
7111 SAS01160 | Indication that a different price applies for special contract customers | — | X | — |
7111 TA01170 | Tariff customers, for electricity § 2. (2) 1b HT or ET (high KA) and for gas § 2 (2) 2b | — | X | — |
7111 TAS01180 | Indication that a different price applies for tariff customers | — | X | — |
7111 TK01190 | for gas under KAV § 2 (2) 2a where used exclusively for cooking and hot water generation | — | X | — |
7111 TKS01200 | Indication when a different price is to be used pursuant to KAV § 2 (2) 2a | — | X | — |
711001210 | Concession levy in euro/kWh | — | Must | [912] ∧ [902] [128] |
711001220 | Fee category of the concession levy | — | Should | [219] |
| SG8.SEQ | — | — | Must | — |
1229 Z1201230 | Municipal discount | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z1601240 | Municipal discount | — | X | — |
606001250 | Quantity | — | X | [902] ∧ [930] ∧ [938] |
6411 P101260 | Percent | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1801270 | Data of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1901280 | Metering location | — | X | — |
115401290 | ID of the metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 ZB301300 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9101310 | MSB | — | X | — |
113101320 | MP-ID | — | X | — |
7110 Z1901330 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2001340 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF001350 | gMSB | — | X | — |
113101360 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Y0201370 | Gas quality | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Y0401380 | H-gas | — | X | — |
7111 Y0501390 | L-gas | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0301400 | Metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1901410 | Metering location | — | X | — |
115401420 | ID of a metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 E1301430 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 NMG01440 | new measuring equipment gas according to MsbG | — | X | — |
7111 DKZ01450 | Rotary piston gas meter | — | X | — |
7111 BGZ01460 | Diaphragm gas meter | — | X | — |
7111 TRZ01470 | Turbine gas meter | — | X | — |
7111 UGZ01480 | Ultrasonic gas meter | — | X | — |
7111 WGZ01490 | Vortex gas meter | — | X | — |
7111 EHZ01500 | electronic household meter | — | X | — |
7111 IVA01510 | Individual reconciliation (special equipment) | — | X | — |
| SG10.CAV | — | — | Must | — |
7110 G1001520 | Gas meter G10 | — | X | — |
7110 G10001530 | Gas meter G100 | — | X | — |
7110 G100001540 | Gas meter G1000 | — | X | — |
7110 G1000001550 | Gas meter G10000 | — | X | — |
7110 G1250001560 | Gas meter G12500 | — | X | — |
7110 G1601570 | Gas meter G16 | — | X | — |
7110 G16001580 | Gas meter G160 | — | X | — |
7110 G160001590 | Gas meter G1600 | — | X | — |
7110 G1600001600 | Gas meter G16000 | — | X | — |
7110 G2.501610 | Gas meter G2.5 | — | X | — |
7110 G2501620 | Gas meter G25 | — | X | — |
7110 G25001630 | Gas meter G250 | — | X | — |
7110 G250001640 | Gas meter G2500 | — | X | — |
7110 G35001650 | Gas meter G350 | — | X | — |
7110 G401660 | Gas meter G4 | — | X | — |
7110 G4001670 | Gas meter G40 | — | X | — |
7110 G40001680 | Gas meter G400 | — | X | — |
7110 G400001690 | Gas meter G4000 | — | X | — |
7110 G601700 | Gas meter G6 | — | X | — |
7110 G6501710 | Gas meter G65 | — | X | — |
7110 G65001720 | Gas meter G650 | — | X | — |
7110 G650001730 | Gas meter G6500 | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001740 | Device number | — | X | — |
711001750 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1201760 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR01770 | remotely readable meters | — | X | — |
7111 MMR01780 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z5001790 | Measurement data recording device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1901800 | Metering location | — | X | — |
115401810 | ID of a metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 E1301820 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001830 | Device number | — | X | — |
711001840 | Device number | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0901850 | Volume corrector data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG01860 | Device number of the meter | — | X | — |
115401870 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6401880 | Volume corrector | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001890 | Device number | — | X | — |
711001900 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 DMU01910 | Density volume converter | — | X | — |
7111 TMU01920 | Temperature volume converter | — | X | — |
7111 ZMU01930 | Volume conversion device | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2001940 | OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [655] |
1153 MG01950 | Device number of the meter | — | X | [442] |
1153 Z1101960 | Device number of the volume converter | — | X | — |
115401970 | Device number | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1901980 | Metering location | — | X | — |
115401990 | ID of a metering location | — | X | [951] |
| SG8.PIA | — | — | Must | — |
4347 502000 | Product identification | — | X | — |
714002010 | OBIS code of the metering device | — | X | [324] |
7143 SRW02020 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE402030 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD902040 | Annually | — | X | — |
7111 ZE802050 | Semi-annual | — | X | — |
7111 ZE902060 | Quarterly | — | X | — |
7111 ZB702070 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1102080 | Product | — | X | — |
7037 Z3302090 | Integer and decimal places of the register | — | X | — |
| SG10.CAV | — | — | Must | — |
711002100 | Digits before the decimal point | — | X | — |
711002110 | Digits after the decimal point | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6302120 | Local identifier for control purposes | — | X | — |
703602130 | Designation of the register on the device | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0502140 | Communication device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG02150 | Device number of the meter | — | X | — |
115402160 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2602170 | Communication device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3002180 | Device number | — | X | — |
711002190 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 GSM02200 | GSM/GPRS/UMTS comm. dev. | — | X | — |
7111 ETH02210 | Ethernet comm. dev. LAN/WLAN | — | X | — |
7111 PLC02220 | PLC comm. device | — | X | — |
7111 PST02230 | Landline comm. dev. TAE | — | X | — |
7111 DSL02240 | DSL comm. dev. | — | X | — |
7111 LTE02250 | LTE comm. dev. | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1302260 | Smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7502270 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3002280 | Device number | — | X | — |
711002290 | Device number | — | X | [952] |
| SG8.SEQ | — | — | Must | — |
1229 Z3502300 | Load profile data | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1202310 | Load profile | — | X | — |
7037 E0102320 | synthetic method | — | X | — |
7037 Z1002330 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711102340 | Code of the load profile | — | X | — |
3055 8902350 | Assigned by the trader (here grid operator) | — | X | — |
3055 29302360 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z9902370 | Measuring station of the daily parameter (currently only the temperature is a permitted daily parameter) | — | X | — |
7059 ZA002380 | Climate zone of the daily parameter (currently is daily parameter) | — | X | — |
703702390 | ID of climate zone / temperature measuring point | — | X | — |
113102400 | Service provider | — | X | [58] |
3055 8902410 | Assigned by the trader (here grid operator) | — | X | — |
3055 29302420 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0902430 | Customer of the LF | — | X | — |
303602440 | Name | — | X | — |
3045 Z0102450 | Structure of person names | — | X | — |
3045 Z0202460 | Structure of the company name | — | X | — |
| SG12.RFF | — | — | Should | [147] |
1153 AVC02470 | Customer number at the supplier | — | X | — |
115402480 | Customer number at the LF | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0402490 | Correspondence address of the customer of the LF | — | X | — |
303602500 | Name | — | X | — |
3045 Z0102510 | Structure of person names | — | X | — |
3045 Z0202520 | Structure of the company name | — | X | — |
304202530 | Street and house number or PO box | — | X | — |
316402540 | City | — | X | — |
325102550 | Postal code | — | — | M [268] S [166] |
320702560 | Country name, code | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 DP02570 | Supply address | — | X | — |
312402580 | Additional information for identification | — | — | — |
304202590 | Street and house number or PO box | — | — | S [166] M [212] |
316402600 | City | — | X | — |
325102610 | Postal code | — | X | — |
320702620 | Country name, code | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0502630 | Name and address for the meter reading card | — | X | — |
303602640 | Name | — | X | — |
3045 Z0102650 | Structure of person names | — | X | — |
3045 Z0202660 | Structure of the company name | — | X | — |
304202670 | Street and house number or PO box | — | X | — |
316402680 | City | — | X | — |
325102690 | Postal code | — | — | M [268] S [166] |
320702700 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1902710 | Metering location | — | X | — |
115402720 | ID of a metering location | — | X | [951] |
| UNT | — | — | Must | — |
007402730 | Number of segments in a message | — | X | — |
006202740 | Message reference number | — | X | — |
Conditions of this table
The free text of the 36 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDG.
| Marker | Condition |
|---|---|
| [10] | If SG4 STS+Z17 (transaction reason for fixed-term registration) is present |
| [18] | If SG4 DTM+93 (end as of) is not present |
| [28] | If SG4 DTM+93 (end as of) is present |
| [29] | If balancing takes place |
| [37] | If the registration/change is limited in time |
| [58] | If in this CCI the DE3055 with the code 293 is present |
| [64] | If SG4 DTM+158 (start of balancing) is present |
| [128] | If SG10 CAV+TAS/TKS/SAS/KAS present |
| [147] | If present in the request |
| [166] | If present |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [216] | If CCI+++Z88 (grid usage) CAV+Z74:::Z08 (grid usage contract: direct contract between customer and NB) present |
| [219] | If present at the market location |
| [230] | Resulting date or end date of the cycle period from DTM+Z21 (date of the grid usage settlement) and DTM+Z09 (next grid usage settlement) must be >= DTM+92 (start on) |
| [249] | Within one SG4 IDE, all DE1131 of the SG4 STS+E01 must contain the identical value |
| [268] | If an "X" is listed for the code in DE3207 in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| [315] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 4, that are required at the market location must be stated; the minimum scope from chapter 4.6 must be observed. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.2 of the document "Code list of configurations" |
| [324] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes chapter 4. that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.2 of the document "Code list of configurations" |
| [442] | If the device number of the meter named in this RFF DE1154 is present in no SG8+SEQ+Z09 volume converter data in the RFF+MG (reference to the device number) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [504] | Note: Code Z22 is also used in the electricity division. The reference to the feed-in tariff interval is not relevant in the gas division |
| [636] | Note: Using a code in DE1153, this RFF classifies the DTM contained in the same segment group as content relevant to a market location or metering location |
| [655] | Note: If a meter is connected to a volume corrector, no OBIS code numbers are stated at the meter Here there are only OBIS code numbers from the volume corrector |
| [902] | Format: Possible value: ≥ 0 |
| [907] | Format: max. 4 decimal places |
| [912] | Format: max. 6 decimal places |
| [930] | Format: max. 2 decimal places |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [938] | Format: Possible value: <= 10 |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [953] | Format: market location ID or metering point identifier |
| [2061] | Segment or segment group must be specified exactly once per SG4 IDE (transaction) |
| [UB2] | ([931] ∧ [934] [490]) ⊻ ([931] ∧ [935] [491]) |
Example message
UNA:+.? '
UNB+UNOC:3+9870016000000:502+9800080300003:502+{{date}}:{{time}}+BC93550838A'
UNH+1+UTILMD:D:11A:UN:G1.2'
BGM+E01+BC93550838A-1'
DTM+137:202610011100?+00:303'
NAD+MS+9870016000000::332'
NAD+MR+9800080300003::332'
IDE+24+ECOUNT_WN_2269944247'
DTM+92:202406010400?+00:303'
DTM+158:202406010400?+00:303'
STS+7++E03'
STS+E01++E15:G_0012'
LOC+172+50605869880'
LOC+172+DE70016045739G0000000000000042897'
RFF+Z13:44002'
RFF+TN:DA019723120221315598000803000039307'
RFF+Z18:50605869880'
DTM+Z20:12:802'
DTM+Z21:01020201:104'
DTM+Z09:2025:602'
DTM+Z22:12:802'
SEQ+Z01'
QTY+31:44000:KWH'
QTY+Y02:158.8448:KWH'
CCI+Z19++THE0BFH007200001'
CCI+Z21++37Y005053MH0000R'
CCI+++Y01'
CAV+Y03'
CCI+++ZA6'
CCI+++Z15'
CCI+++Z88'
CAV+Z74:::Z09'
CAV+Z73:::Z11'
CAV+ZB1:::Z14'
SEQ+Z02'
PIA+5+7-0?:33.86.0:SRW'
CCI+++ZE4'
CAV+ZD9'
SEQ+Z07'
RFF+Z10:7-0?:33.86.0'
CCI+++Z08'
CAV+SA'
SEQ+Z12'
QTY+Z16:0:P1'
SEQ+Z18'
RFF+Z19:DE70016045739G0000000000000042897'
CCI+++ZB3'
CAV+Z91:9800172600006::Z19'
CAV+ZF0:9800172600006'
CCI+++Y02'
CAV+Y04'
SEQ+Z03'
RFF+Z19:DE70016045739G0000000000000042897'
CCI+++E13'
CAV+BGZ'
CAV+:::G4'
CAV+Z30:::7AMX2002565930'
CCI+++E12'
CAV+MMR'
SEQ+Z20'
RFF+MG:7AMX2002565930'
RFF+Z19:DE70016045739G0000000000000042897'
PIA+5+7-20?:3.0.0:SRW'
CCI+++ZE4'
CAV+ZD9'
CCI+11++Z33'
CAV+:::5:3'
SEQ+Z35'
CCI+Z12++E01'
CAV+N14::293'
CCI+ZA0++Werl::89'
NAD+Z09+++Höllerhage:Hannelore::::Z01'
NAD+Z04+++Höllerhage:Hannelore::::Z01+Haydnstr.::24+Oer-Erkenschwick++45739+DE'
NAD+DP++++Haydnstr.::24:Groß-Erkenschwick+Oer-Erkenschwick++45739+DE'
NAD+Z05+++Höllerhage:Hannelore::::Z01+Haydnstr.::24+Oer-Erkenschwick++45739+DE'
RFF+Z19:DE70016045739G0000000000000042897'
UNT+75+1'
UNZ+1+BC93550838A'[1 item
{6 fields
"data": {3 fields
"stammdaten": {6 fields
"MARKTLOKATION": [1 item
{8 fields
"lokationsadresse": {6 fields
"zaehlwerke": [1 item
{3 fields
"konzessionsabgabe": {1 field
"MESSLOKATION": [1 item
{7 fields
"ablesekartenempfaenger": {7 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {5 fields
"marktrollen": [2 items
{5 fields
{4 fields
"NETZNUTZUNGSVERTRAG": [1 item
{9 fields
"vertragskonditionen": {7 fields
"netznutzungsabrechnung": {1 field
"ENERGIELIEFERVERTRAG": [1 item
{9 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"vertragskonditionen": {1 field
"korrespondenzpartner": {6 fields
"partneradresse": {5 fields
"ZAEHLER": [1 item
{10 fields
"zaehlwerke": [1 item
{4 fields
"geraete": [1 item
{1 field
"BILANZIERUNG": [1 item
{9 fields
"lastprofile": [1 item
{6 fields
"tagesparameter": {2 fields
"bilanzkreise": [1 item
{1 field
"jahresverbrauchsprognose": {2 fields
"kundenwert": {1 field
"transaktionsdaten": {14 fields
"absender": {4 fields
"empfaenger": {4 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF and NB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LFA | Start of supply | GeLi Gas 2.0 | Gas | Step 5 |
| LF | LFN | Start of supply | GeLi Gas 2.0 | Gas | Step 5 |
| LF | LFZ | Start of supply | GeLi Gas 2.0 | Gas | Step 5 |
| NB | NB | Start of supply | GeLi Gas 2.0 | Gas | Step 5 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Confirmation of registration |
| AHB | UTILMD AHB gas |
| Decision tree | E_3007 |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GeLi Gas 2.0 | Start of supply | NB → LF (corresponds to LFN) | Response to registration |
| GeLi Gas | Ch. B 3.3 No. 4b | NB → LF | Confirmation of the registration |
Transaction and responses
Role of this check identifier: response — confirmation. Basis: the transaction data carry antwortstatus and antwortstatusCodeliste; the title or the action of the Prüfi table begins with “response”; the title names a polarity (confirmation).
Request: No reference recorded in the source. Neither the Prüfi table (reaktion_auf) nor the step sequence of the processes names the message that this response answers.
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfragereferenznummer | SG4.IDE+24.SG6.RFF+TN | vorgangsnummer |
For RFF+TN, the field description of the time slice names the »reference transaction number (from request message)« — the target is the vorgangsnummer in segment SG4.IDE+24 of the request. Which request is meant is not determined on this page (see above) — the target field is thus named, but not proven.
Response codes
Decision trees: G_0012 · E_3007.
The Prüfi table names one further tree across all rows of this check identifier. They tie it to a process, not to a row of its handbook — their codes are therefore only on the respective tree page. For G_0012 there is no decision tree in version 202610; its response codes are therefore not given here.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDG has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 372 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type utilmdGas. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.