Check identifier 44116 — Change from MSB with dependencies
Check identifier 44116 · EDIFACT message type UTILMD_GAS · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 44116 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| messlokationsId * 00010 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| NETZNUTZUNGSVERTRAG [ ] | — | object[] | May | — |
| vertragsbeginn 00020 | Specifies when the contract begins. | string (date-time) | X | — |
| ZAEHLER [ ] * | — | object[] | Must | — |
| befestigungsart * 00030 | Mounting type | Enum Befestigungsart | Must | — |
STECKTECHNIK | — | — | Must | — |
DREIPUNKT | — | — | Must | — |
HUTSCHIENE | — | — | Must | — |
EINSTUTZEN | — | — | Must | — |
ZWEISTUTZEN | — | — | Must | — |
| messlokationsId * 00040 | messlokationsId | string | X | — |
| messwerterfassung * 00050 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| volumenerfassung 00060 | Volume measurement | Enum Volumenerfassung | X | — |
HOCHFREQUENZSONDE | — | — | X | — |
KENNLINIENKORREKTUR | — | — | X | — |
SCHLEICHMENGENUNTERDRUECKUNG | — | — | X | — |
| zaehlergroesse * 00070 | Meter size | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlernummer * 00080 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp * 00090 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 00100 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 00110 | The number printed on the device, which is assigned by the MSB. | string | X | — |
| geraeteeigenschaften | — | object | May | — |
| geraetemerkmal 00120 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| volumenerfassung 00130 | Volume measurement | Enum Volumenerfassung | X | — |
HOCHFREQUENZSONDE | — | — | X | — |
KENNLINIENKORREKTUR | — | — | X | — |
SCHLEICHMENGENUNTERDRUECKUNG | — | — | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| bezeichnung 00140 | Additional designation, e.g. Zählwerk_Wirkarbeit. | string | Must | — |
| nachkommastelle 00150 | nachkommastelle | integer | Must | — |
| obisKennzahl 00160 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| vorkommastelle 00170 | vorkommastelle | integer | Must | — |
| wertegranularitaet 00180 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| dokumentennummer * 00190 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| gueltigAb * 00200 | Effective date/time / DTM+7 | string (date-time) | X | — |
| kategorie * 00210 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 00220 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00230 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00240 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 00250 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vertragsbeginn 00260 | Contract start date / DTM+92 | string (date-time) | X | — |
| vorgangsnummer * 00270 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00280 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00290 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00300 | Email address | string | Must | — |
| nachname 00310 | Surname (family name) of the contact person | string | X | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00320 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00330 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00340 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00350 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 44116 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 G1.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0300070 | Change notifications | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/ message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/ message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 33200150 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00160 | Information contact | — | X | — |
341200170 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800180 | Number / address | — | X | — |
3155 EM00190 | Electronic mail | — | X | [1P0..1] |
3155 FX00200 | Fax number | — | X | [1P0..1] |
3155 TE00210 | Telephone | — | X | [1P0..1] |
3155 AJ00220 | further telephone | — | X | [1P0..1] |
3155 AL00230 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00240 | Message recipient | — | X | — |
303900250 | MP-ID | — | X | — |
3055 900260 | GS1 | — | X | — |
3055 33200270 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400280 | Transaction | — | X | — |
740200290 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 9200300 | Contract start date | — | X | — |
238000310 | Date or time or time span, value | — | X | [UB2] |
2379 30300320 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 15700330 | Validity, start date | — | X | — |
238000340 | Date or time or time span, value | — | X | [UB2] |
2379 30300350 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.STS | — | — | Must | [2061] |
9015 700360 | Transaction reason | — | X | — |
9013 ZE800370 | Change from the MSB with dependencies | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 17200380 | Reporting point | — | X | — |
322500390 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300400 | Check identifier | — | X | — |
1154 4411600410 | SDÄ gas / change from MSB to NB | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0300420 | Metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1900430 | Metering location | — | X | — |
115400440 | ID of a metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 E1300450 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 NMG00460 | new measuring equipment gas according to MsbG | — | X | — |
7111 DKZ00470 | Rotary piston gas meter | — | X | — |
7111 BGZ00480 | Diaphragm gas meter | — | X | — |
7111 TRZ00490 | Turbine gas meter | — | X | — |
7111 UGZ00500 | Ultrasonic gas meter | — | X | — |
7111 WGZ00510 | Vortex gas meter | — | X | — |
7111 EHZ00520 | electronic household meter | — | X | — |
7111 IVA00530 | Individual reconciliation (special equipment) | — | X | — |
| SG10.CAV | — | — | Must | — |
7110 G1000540 | Gas meter G10 | — | X | — |
7110 G10000550 | Gas meter G100 | — | X | — |
7110 G100000560 | Gas meter G1000 | — | X | — |
7110 G1000000570 | Gas meter G10000 | — | X | — |
7110 G1250000580 | Gas meter G12500 | — | X | — |
7110 G1600590 | Gas meter G16 | — | X | — |
7110 G16000600 | Gas meter G160 | — | X | — |
7110 G160000610 | Gas meter G1600 | — | X | — |
7110 G1600000620 | Gas meter G16000 | — | X | — |
7110 G2.500630 | Gas meter G2.5 | — | X | — |
7110 G2500640 | Gas meter G25 | — | X | — |
7110 G25000650 | Gas meter G250 | — | X | — |
7110 G250000660 | Gas meter G2500 | — | X | — |
7110 G35000670 | Gas meter G350 | — | X | — |
7110 G400680 | Gas meter G4 | — | X | — |
7110 G4000690 | Gas meter G40 | — | X | — |
7110 G40000700 | Gas meter G400 | — | X | — |
7110 G400000710 | Gas meter G4000 | — | X | — |
7110 G600720 | Gas meter G6 | — | X | — |
7110 G6500730 | Gas meter G65 | — | X | — |
7110 G65000740 | Gas meter G650 | — | X | — |
7110 G650000750 | Gas meter G6500 | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3000760 | Device number | — | X | — |
711000770 | Device number | — | X | — |
| SG10.CAV | — | — | Should | [166] |
7111 ZC000780 | Type of volume measurement | — | X | — |
7110 Z1600790 | High-frequency probe | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2800800 | Mounting type metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3100810 | Single-connection meter | — | X | — |
7111 Z3200820 | Two-connection meter | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1200830 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR00840 | remotely readable meters | — | X | — |
7111 MMR00850 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z5000860 | Measurement data recording device data | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1300870 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3000880 | Device number | — | X | — |
711000890 | Device number | — | X | — |
| SG10.CAV | — | — | Should | [166] |
7111 ZC000900 | Type of volume measurement | — | X | — |
7110 Z1600910 | High-frequency probe | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0900920 | Volume corrector data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG00930 | Device number of the meter | — | X | — |
115400940 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6400950 | Volume corrector | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3000960 | Device number | — | X | — |
711000970 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 DMU00980 | Density volume converter | — | X | — |
7111 TMU00990 | Temperature volume converter | — | X | — |
7111 ZMU01000 | Volume conversion devic e | — | X | — |
| SG10.CAV | — | — | Should | [166] |
7111 ZC001010 | Type of volume measurement | — | X | — |
7110 Z1701020 | Characteristic curve correction | — | X | — |
7110 Z1801030 | Creep flow suppression | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2001040 | OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [655] |
1153 MG01050 | Device number of the meter | — | X | [442] |
1153 Z1101060 | Device number of the volume converter | — | X | — |
115401070 | Device number | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1901080 | Metering location | — | X | — |
115401090 | ID of a metering location | — | X | [951] |
| SG8.PIA | — | — | Must | — |
4347 501100 | Product identification | — | X | — |
714001110 | OBIS code of the metering device | — | X | [324] |
7143 SRW01120 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401130 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD901140 | Annually | — | X | — |
7111 ZE801150 | Semi-annual | — | X | — |
7111 ZE901160 | Quarterly | — | X | — |
7111 ZB701170 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1101180 | Product | — | X | — |
7037 Z3301190 | Integer and decimal places of the register | — | X | — |
| SG10.CAV | — | — | Must | — |
711001200 | Digits before the decimal point | — | X | — |
711001210 | Digits after the decimal point | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6301220 | Local identifier for control purposes | — | X | — |
703601230 | Designation of the register on the device | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0501240 | Communication device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG01250 | Device number of the meter | — | X | — |
115401260 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2601270 | Communication device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001280 | Device number | — | X | — |
711001290 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 GSM01300 | GSM/GPRS/UMTS- comm. dev. | — | X | — |
7111 ETH01310 | Ethernet comm. dev. LAN/WLAN | — | X | — |
7111 PLC01320 | PLC comm. device | — | X | — |
7111 PST01330 | Landline comm. dev. TAE | — | X | — |
7111 DSL01340 | DSL comm. dev. | — | X | — |
7111 LTE01350 | LTE comm. dev. | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1301360 | Smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7501370 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001380 | Device number | — | X | — |
711001390 | Device number | — | X | [952] |
| UNT | — | — | Must | — |
007401400 | Number of segments in a message | — | X | — |
006201410 | Message reference number | — | X | — |
Conditions of this table
The free text of the 11 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDG.
| Marker | Condition |
|---|---|
| [166] | If present |
| [324] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes chapter 4. that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.2 of the document "Code list of configurations" |
| [442] | If the device number of the meter named in this RFF DE1154 is present in no SG8+SEQ+Z09 volume converter data in the RFF+MG (reference to the device number) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [655] | Note: If a meter is connected to a volume corrector, no OBIS code numbers are stated at the meter Here there are only OBIS code numbers from the volume corrector |
| [931] | Format: ZZZ = +00 |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [2061] | Segment or segment group must be specified exactly once per SG4 IDE (transaction) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [UB2] | ([931] ∧ [934] [490]) ⊻ ([931] ∧ [935] [491]) |
Example message
UNA:+.? '
UNB+UNOC:3+9800191400007:502+9870006600000:502+{{date}}:{{time}}+MHB2A59H'
UNH+UNHMGW7Y4Z3+UTILMD:D:11A:UN:G1.1'
BGM+E03+BGMMGNPBRVU'
DTM+137:202604010624?+00:303'
NAD+MS+9800191400007::332'
NAD+MR+9870006600000::332'
IDE+24+99009520000021107201601760435796973'
DTM+92:202605010400?+00:303'
DTM+157:202605010400?+00:303'
STS+7++ZE8'
LOC+172+DE70016045739G0000000000000042897'
RFF+Z13:44116'
SEQ+Z03'
RFF+Z19:DE70016045739G0000000000000042897'
CCI+++E13'
CAV+BGZ'
CAV+:::G10'
CAV+Z30:::GAS123456'
CAV+ZC0:::Z16'
CCI+++Z28'
CAV+Z31'
CCI+++E12'
CAV+MMR'
SEQ+Z20'
RFF+MG:GAS123456'
RFF+Z19:DE70016045739G0000000000000042897'
PIA+5+7-0?:3.0.0:SRW'
CCI+++ZE4'
CAV+ZD9'
CCI+11++Z33'
CAV+:::7:3'
UNT+31+UNHMGW7Y4Z3'
UNZ+1+MHB2A59H'[1 item
{6 fields
"data": {3 fields
"stammdaten": {3 fields
"MESSLOKATION": [1 item
{4 fields
"NETZNUTZUNGSVERTRAG": [1 item
{7 fields
"ZAEHLER": [1 item
{11 fields
"zaehlwerke": [1 item
{4 fields
"transaktionsdaten": {13 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Master data change initiated by the MSB (responsible) | GeLi Gas 2.0 | Gas | Step 1 |
| NB | NB | Master data change initiated by the MSB (responsible) | GeLi Gas 2.0 | Gas | Step 1 |
| MSB | MSB | Master data change initiated by the MSB (responsible) | GeLi Gas 2.0 | Gas | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Change from the MSB with dependencies |
| AHB | UTILMD AHB gas |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GeLi Gas 2.0 | Master data change initiated by the MSB (responsible) | MSB → NB | Change from the MSB |
| GeLi Gas | Ch. D 2.2.3 No. 1 | MSB → NB [distributor] | Change from the MSB |
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.
Which messages respond to this
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Response | 44119 | Response to change from the MSB | UTILMD_GAS | explicit |
This column is the inverse of the assignment on the response pages — not the next step of a list. The process source says of its own steps that they are »possible messages, not a sequence«.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDG has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 193 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type utilmdGas. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.