Check identifier 44060 — Response to the business data request
Check identifier 44060 · EDIFACT message type UTILMD_GAS · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 44060 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| gasqualitaet * 00010 | gasqualitaet for EDIFACT mapping | Enum Gasqualitaet | Must | — |
H_GAS | — | — | Must | — |
L_GAS | — | — | Must | — |
| messlokationsId * 00020 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| marktrollen [ ] * | — | object[] | Must | — |
| marktrolle 00030 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| rollencodenummer * 00040 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet * 00050 | weiterverpflichtet | boolean | X | — |
| messadresse | — | object | May | — |
| hausnummer 00060 | House number and supplement | string | X | — |
| landescode 00070 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00080 | City | string | X | — |
| ortsteil 00090 | District | string | X | — |
| postfach 00100 | PO box | string | X | — |
| postleitzahl 00110 | Postal code | string | X | — |
| strasse 00120 | Street | string | X | — |
| zusatzInformation | — | object | May | — |
| zusatz1 00130 | Address supplement 1 | string | X | — |
| zusatz2 00140 | Address supplement 2 | string | X | — |
| zusatz3 00150 | Address supplement 3 | string | X | — |
| zusatz4 00160 | Address supplement 4 | string | X | — |
| zusatz5 00170 | Address supplement 5 | string | X | — |
| zaehlwerke [ ] * | — | object[] | Must | — |
| messprodukt * 00180 | messprodukt | string | X | — |
| MESSSTELLENBETRIEBSVERTRAG [ ] * | — | object[] | Must | — |
| lokationsId * 00190 | lokationsId | string | X | — |
| lokationsTyp * 00200 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | X | — |
MALO | — | — | X | — |
MELO | — | — | X | — |
NELO | — | — | X | — |
TECHNISCHE_RESSOURCE | — | — | X | — |
STEUERBARE_RESSOURCE | — | — | X | — |
TRANCHE | — | — | X | — |
MABIS_ZAEHLPUNKT | — | — | X | — |
| vertragskonditionen * | — | object | Must | — |
| geplanteTurnusablesung * | — | object | Must | — |
| ableseZeitraum * 00210 | ableseZeitraum | string | X | — |
| ZAEHLER [ ] | — | object[] | May | — |
| befestigungsart 00220 | Mounting type | Enum Befestigungsart | Must | — |
STECKTECHNIK | — | — | Must | — |
DREIPUNKT | — | — | Must | — |
HUTSCHIENE | — | — | Must | — |
EINSTUTZEN | — | — | Must | — |
ZWEISTUTZEN | — | — | Must | — |
| messlokationsId 00230 | messlokationsId | string | X | — |
| messwerterfassung 00240 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| volumenerfassung 00250 | Volume measurement | Enum Volumenerfassung | X | — |
HOCHFREQUENZSONDE | — | — | X | — |
KENNLINIENKORREKTUR | — | — | X | — |
SCHLEICHMENGENUNTERDRUECKUNG | — | — | X | — |
| zaehlergroesse 00260 | Meter size | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlernummer 00270 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 00280 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 00290 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 00300 | The number printed on the device, which is assigned by the MSB. | string | X | — |
| geraeteeigenschaften | — | object | May | — |
| geraetemerkmal 00310 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| volumenerfassung 00320 | Volume measurement | Enum Volumenerfassung | X | — |
HOCHFREQUENZSONDE | — | — | X | — |
KENNLINIENKORREKTUR | — | — | X | — |
SCHLEICHMENGENUNTERDRUECKUNG | — | — | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| bezeichnung 00330 | Additional designation, e.g. Zählwerk_Wirkarbeit. | string | Must | — |
| nachkommastelle 00340 | nachkommastelle | integer | Must | — |
| obisKennzahl 00350 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| vorkommastelle 00360 | vorkommastelle | integer | Must | — |
| wertegranularitaet 00370 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer * 00380 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| dokumentennummer * 00390 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| kategorie * 00400 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 00410 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00420 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00430 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 00440 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vorgangsnummer * 00450 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00460 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00470 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00480 | Email address | string | Must | — |
| nachname 00490 | Surname (family name) of the contact person | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00500 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00510 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00520 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00530 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 44060 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 G1.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z1400070 | Master data of the market or metering location | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/ message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/ message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 33200150 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00160 | Information contact | — | X | — |
341200170 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800180 | Number / address | — | X | — |
3155 EM00190 | Electronic mail | — | X | [1P0..1] |
3155 FX00200 | Fax number | — | X | [1P0..1] |
3155 TE00210 | Telephone | — | X | [1P0..1] |
3155 AJ00220 | further telephone | — | X | [1P0..1] |
3155 AL00230 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00240 | Message recipient | — | X | — |
303900250 | MP-ID | — | X | — |
3055 900260 | GS1 | — | X | — |
3055 33200270 | DE, DVGW Service & Consult GmbH | — | X | — |
3055 29300280 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400290 | Transaction | — | X | — |
740200300 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | [2061] |
9015 700310 | Transaction reason | — | X | — |
9013 Z4000320 | Business data request | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 17200330 | Reporting point | — | X | — |
322500340 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300350 | Check identifier | — | X | — |
1154 4406000360 | WiM gas / response to the MSB business data request | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 AAV00370 | Number of the request | — | X | — |
115400380 | Transaction number | — | X | — |
| SG6.RFF | — | — | Must | [636] |
1153 Z1900390 | Metering location | — | X | — |
115400400 | ID of the metering location | — | X | [951] |
| SG6.DTM | — | — | Must | — |
2005 75200410 | Periodic meter reading | — | X | — |
238000420 | Date or time or time span, value | — | X | — |
2379 10400430 | MMWW-MMWW | — | X | — |
2379 10600440 | MMDD | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1800450 | Data of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1900460 | Metering location | — | X | — |
115400470 | ID of the metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 ZB300480 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9100490 | MSB | — | X | — |
113100500 | MP-ID | — | X | — |
7110 Z1900510 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2000520 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF000530 | gMSB | — | X | — |
113100540 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Y0200550 | Gas quality | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Y0400560 | H-gas | — | X | — |
7111 Y0500570 | L-gas | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1900580 | Required product of the metering location | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 500590 | Product identification | — | X | — |
714000600 | Metering product code | — | X | [427] |
7143 Z1100610 | Product | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0300620 | Metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1900630 | Metering location | — | X | — |
115400640 | ID of a metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 E1300650 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 NMG00660 | new measuring equipment gas according to MsbG | — | X | — |
7111 DKZ00670 | Rotary piston gas meter | — | X | — |
7111 BGZ00680 | Diaphragm gas meter | — | X | — |
7111 TRZ00690 | Turbine gas meter | — | X | — |
7111 UGZ00700 | Ultrasonic gas meter | — | X | — |
7111 WGZ00710 | Vortex gas meter | — | X | — |
7111 EHZ00720 | electronic household meter | — | X | — |
7111 IVA00730 | Individual reconciliation (special equipment) | — | X | — |
| SG10.CAV | — | — | Must | — |
7110 G1000740 | Gas meter G10 | — | X | — |
7110 G10000750 | Gas meter G100 | — | X | — |
7110 G100000760 | Gas meter G1000 | — | X | — |
7110 G1000000770 | Gas meter G10000 | — | X | — |
7110 G1250000780 | Gas meter G12500 | — | X | — |
7110 G1600790 | Gas meter G16 | — | X | — |
7110 G16000800 | Gas meter G160 | — | X | — |
7110 G160000810 | Gas meter G1600 | — | X | — |
7110 G1600000820 | Gas meter G16000 | — | X | — |
7110 G2.500830 | Gas meter G2.5 | — | X | — |
7110 G2500840 | Gas meter G25 | — | X | — |
7110 G25000850 | Gas meter G250 | — | X | — |
7110 G250000860 | Gas meter G2500 | — | X | — |
7110 G35000870 | Gas meter G350 | — | X | — |
7110 G400880 | Gas meter G4 | — | X | — |
7110 G4000890 | Gas meter G40 | — | X | — |
7110 G40000900 | Gas meter G400 | — | X | — |
7110 G400000910 | Gas meter G4000 | — | X | — |
7110 G600920 | Gas meter G6 | — | X | — |
7110 G6500930 | Gas meter G65 | — | X | — |
7110 G65000940 | Gas meter G650 | — | X | — |
7110 G650000950 | Gas meter G6500 | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3000960 | Device number | — | X | — |
711000970 | Device number | — | X | — |
| SG10.CAV | — | — | Should | [166] |
7111 ZC000980 | Type of volume measurement | — | X | — |
7110 Z1600990 | High-frequency probe | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2801000 | Mounting type metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3101010 | Single-connection meter | — | X | — |
7111 Z3201020 | Two-connection meter | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1201030 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR01040 | remotely readable meters | — | X | — |
7111 MMR01050 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z5001060 | Measurement data recording device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1901070 | Metering location | — | X | — |
115401080 | ID of a metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 E1301090 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001100 | Device number | — | X | — |
711001110 | Device number | — | X | — |
| SG10.CAV | — | — | Should | [166] |
7111 ZC001120 | Type of volume measurement | — | X | — |
7110 Z1601130 | High-frequency probe | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0901140 | Volume corrector data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG01150 | Device number of the meter | — | X | — |
115401160 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6401170 | Volume corrector | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001180 | Device number | — | X | — |
711001190 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 DMU01200 | Density volume converter | — | X | — |
7111 TMU01210 | Temperature volume converter | — | X | — |
7111 ZMU01220 | Volume conversion device | — | X | — |
| SG10.CAV | — | — | Should | [166] |
7111 ZC001230 | Type of volume measurement | — | X | — |
7110 Z1701240 | Characteristic curve correction | — | X | — |
7110 Z1801250 | Creep flow suppression | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2001260 | OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [655] |
1153 MG01270 | Device number of the meter | — | X | [442] |
1153 Z1101280 | Device number of the volume converter | — | X | — |
115401290 | Device number | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1901300 | Metering location | — | X | — |
115401310 | ID of a metering location | — | X | [951] |
| SG8.PIA | — | — | Must | — |
4347 501320 | Product identification | — | X | — |
714001330 | OBIS code of the metering device | — | X | [324] |
7143 SRW01340 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401350 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD901360 | Annually | — | X | — |
7111 ZE801370 | Semi-annual | — | X | — |
7111 ZE901380 | Quarterly | — | X | — |
7111 ZB701390 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1101400 | Product | — | X | — |
7037 Z3301410 | Integer and decimal places of the register | — | X | — |
| SG10.CAV | — | — | Must | — |
711001420 | Digits before the decimal point | — | X | — |
711001430 | Digits after the decimal point | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6301440 | Local identifier for control purposes | — | X | — |
703601450 | Designation of the register on the device | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0501460 | Communication device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG01470 | Device number of the meter | — | X | — |
115401480 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2601490 | Communication device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001500 | Device number | — | X | — |
711001510 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 GSM01520 | GSM/GPRS/UMTS comm. dev. | — | X | — |
7111 ETH01530 | Ethernet comm. dev. LAN/WLAN | — | X | — |
7111 PLC01540 | PLC comm. device | — | X | — |
7111 PST01550 | Landline comm. dev. TAE | — | X | — |
7111 DSL01560 | DSL comm. dev. | — | X | — |
7111 LTE01570 | LTE comm. dev. | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1301580 | Smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7501590 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001600 | Device number | — | X | — |
711001610 | Device number | — | X | [952] |
| SG12.NAD | — | — | Must | — |
3035 Z0301620 | Metering location address | — | X | — |
312401630 | Additional information for identification | — | — | — |
304201640 | Street and house number or PO box | — | — | S [166] M [212] |
316401650 | City | — | X | — |
325101660 | Postal code | — | X | — |
320701670 | Country name, code | — | X | — |
| UNT | — | — | Must | — |
007401680 | Number of segments in a message | — | X | — |
006201690 | Message reference number | — | X | — |
Conditions of this table
The free text of the 13 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDG.
| Marker | Condition |
|---|---|
| [166] | If present |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [324] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes chapter 4. that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.2 of the document "Code list of configurations" |
| [427] | Metering product code from chapter 3 "Code list of the standard metering products gas" of the code list of configurations |
| [442] | If the device number of the meter named in this RFF DE1154 is present in no SG8+SEQ+Z09 volume converter data in the RFF+MG (reference to the device number) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [636] | Note: Using a code in DE1153, this RFF classifies the DTM contained in the same segment group as content relevant to a market location or metering location |
| [655] | Note: If a meter is connected to a volume corrector, no OBIS code numbers are stated at the meter Here there are only OBIS code numbers from the volume corrector |
| [931] | Format: ZZZ = +00 |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [2061] | Segment or segment group must be specified exactly once per SG4 IDE (transaction) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
UNA:+.? '
UNB+UNOC:3+9870013800007:502+9800110000002:502+{{date}}:{{time}}+155532'
UNH+140793+UTILMD:D:11A:UN:G1.1'
BGM+Z14+140793BGM'
DTM+137:202604010624?+00:303'
NAD+MS+9870013800007::332'
NAD+MR+9800110000002::332'
IDE+24+2126663982'
STS+7++Z40'
LOC+172+DE70016045739G0000000000000042897'
RFF+Z13:44060'
RFF+AAV:12345678910'
RFF+Z19:DE70016045739G0000000000000042897'
DTM+752:0101:106'
SEQ+Z18'
RFF+Z19:DE70016045739G0000000000000042897'
CCI+++ZB3'
CAV+Z91:9800110000002::Z19'
CAV+ZF0:9800110000002'
CCI+++Y02'
CAV+Y04'
SEQ+Z19'
PIA+5+9991000000383:Z11'
SEQ+Z03'
RFF+Z19:DE70016045739G0000000000000042897'
CCI+++E13'
CAV+BGZ'
CAV+:::G4'
CAV+Z30:::ABC123456'
CCI+++Z28'
CAV+Z31'
CCI+++E12'
CAV+MMR'
SEQ+Z20'
RFF+MG:ABC123456'
RFF+Z19:DE70016045739G0000000000000042897'
PIA+5+7-20?:3.0.0:SRW'
CCI+++ZE4'
CAV+ZD9'
CCI+11++Z33'
CAV+:::5:3'
NAD+Z03++Mustermann++Str::1+Ort++12345+DE'
UNT+41+140793'
UNZ+1+155532'[1 item
{6 fields
"data": {3 fields
"stammdaten": {3 fields
"MESSLOKATION": [1 item
{8 fields
"messadresse": {6 fields
"zusatzInformation": {1 field
"zaehlwerke": [1 item
{1 field
"marktrollen": [2 items
{5 fields
{4 fields
"MESSSTELLENBETRIEBSVERTRAG": [1 item
{7 fields
"vertragskonditionen": {1 field
"geplanteTurnusablesung": {1 field
"ZAEHLER": [1 item
{11 fields
"zaehlwerke": [1 item
{4 fields
"geraete": [1 item
{1 field
"transaktionsdaten": {12 fields
"absender": {4 fields
"empfaenger": {4 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | NB | Business data request from the MSB to NB | GeLi Gas 2.0 | Gas | Step 2 |
| MSB | MSB | Business data request from the MSB to NB | GeLi Gas 2.0 | Gas | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response to the business data request |
| AHB | UTILMD AHB gas |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GeLi Gas 2.0 | Business data request from MSB to NB | NB → MSB (electricity / gas) | Response |
| GeLi Gas | Ch. D 3.3 No. 2 | NB → MSB | Response |
Transaction and responses
Role of this check identifier: response. Basis: the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 17126 | Request for master data of metering location (gas) | ORDERS | from the step sequence |
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfragereferenznummer | SG4.IDE+24.SG6.RFF+AAV | dokumentennummer |
RFF+AAV quotes the preceding message via its BGM; the target is the dokumentennummer of the request. Measured: 17126 carries dokumentennummer in BGM+Z62.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDG has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 233 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type utilmdGas. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.