Check identifier 44014 — Confirmation of EoG registration
Check identifier 44014 · EDIFACT message type UTILMD_GAS · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 44014 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| BILANZIERUNG [ ] * | — | object[] | Must | — |
| bilanzierungsbeginn 00010 | Inclusive start of the balancing | string (date-time) | X | — |
| bilanzierungsende 00020 | Exclusive end of balancing | string (date-time) | X | — |
| fallgruppenzuordnung 00030 | Case group assignment (for gas RLM) | Enum Fallgruppenzuordnung | Must | — |
GABI_RLMmT | — | — | Must | — |
GABI_RLMoT | — | — | Must | — |
GABI_RLMNEV | — | — | Must | — |
| prognosegrundlage * 00040 | Forecast basis | Enum Prognosegrundlage | Must | — |
WERTE | — | — | Must | — |
PROFILE | — | — | Must | — |
| bilanzkreise [ ] | — | object[] | May | — |
| bezeichnung 00050 | External designation | string | X | — |
| jahresverbrauchsprognose | — | object | May | — |
| einheit 00060 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 00070 | Value | number (float) | X | — |
| kundenwert | — | object | May | — |
| wert 00080 | Value | number (float) | X | — |
| lastprofile [ ] | — | object[] | May | — |
| bezeichnung 00090 | Designation of the profile | string | Must | — |
| herausgeber 00100 | Issuer of the load profile | string | Must | — |
| verfahren 00110 | Profiling method | Enum Profilverfahren | X | — |
SYNTHETISCH | — | — | X | — |
ANALYTISCH | — | — | X | — |
| tagesparameter | — | object | May | — |
| dienstanbieter 00120 | dienstanbieter | string | Must | — |
| herausgeber 00130 | Herausgeber | Enum Herausgeber | Must | — |
NB | — | — | Must | — |
BDEW | — | — | Must | — |
TUM | — | — | Must | — |
| klimazone 00140 | klimazone | string | Must | — |
| temperaturmessstelle 00150 | temperaturmessstelle | string | Must | — |
| ENERGIELIEFERVERTRAG [ ] * | — | object[] | Must | — |
| korrespondenzpartner | — | object | May | — |
| anrede 00160 | The form of address for the GePa, e.g. Mr. | string | X | — |
| gewerbekennzeichnung 00170 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | X | — |
| name1 00180 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00190 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00200 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00210 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 00220 | House number and supplement | string | X | — |
| landescode 00230 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00240 | City | string | X | — |
| ortsteil 00250 | District | string | X | — |
| postfach 00260 | PO box | string | X | — |
| postleitzahl 00270 | Postal code | string | X | — |
| strasse 00280 | Street | string | X | — |
| vertragskonditionen * | — | object | Must | — |
| abrechnungsintervall * 00290 | abrechnungsintervall | integer | X | — |
| vertragspartner2 [ ] | — | object[] | May | — |
| anrede 00300 | The form of address for the GePa, e.g. Mr. | string | X | — |
| gewerbekennzeichnung 00310 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | X | — |
| name1 00320 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00330 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00340 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00350 | name4 | string | X | — |
| MARKTLOKATION [ ] * | — | object[] | Must | — |
| marktgebiet * 00360 | for EDIFACT mapping | string | X | — |
| marktlokationsId * 00370 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| netzebene * 00380 | Grid level at which the energy is drawn. For electricity, the voltage level of the supply; for gas, the pressure level. Example electricity: low voltage Example gas: low pressure. | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| lokationsadresse | — | object | May | — |
| hausnummer 00390 | House number and supplement | string | X | — |
| landescode 00400 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00410 | City | string | X | — |
| ortsteil 00420 | District | string | X | — |
| postfach 00430 | PO box | string | X | — |
| postleitzahl 00440 | Postal code | string | X | — |
| strasse 00450 | Street | string | X | — |
| zusatzInformation | — | object | May | — |
| zusatz1 00460 | Address supplement 1 | string | X | — |
| zusatz2 00470 | Address supplement 2 | string | X | — |
| zusatz3 00480 | Address supplement 3 | string | X | — |
| zusatz4 00490 | Address supplement 4 | string | X | — |
| zusatz5 00500 | Address supplement 5 | string | X | — |
| zaehlwerke [ ] * | — | object[] | Must | — |
| obisKennzahl * 00510 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| wertegranularitaet 00520 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| konzessionsabgabe | — | object | May | — |
| kategorie 00530 | Category | string | Must | — |
| kosten 00540 | Costs | number (float) | Must | — |
| satz 00550 | Type of concession levy | Enum AbgabeArt | Must | — |
KAS | — | — | Must | — |
SA | — | — | Must | — |
SAS | — | — | Must | — |
TA | — | — | Must | — |
TAS | — | — | Must | — |
TK | — | — | Must | — |
TKS | — | — | Must | — |
TS | — | — | Must | — |
TSS | — | — | Must | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| gasqualitaet 00560 | gasqualitaet for EDIFACT mapping | Enum Gasqualitaet | Must | — |
H_GAS | — | — | Must | — |
L_GAS | — | — | Must | — |
| messlokationsId * 00570 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| ablesekartenempfaenger | — | object | May | — |
| anrede 00580 | The form of address for the GePa, e.g. Mr. | string | X | — |
| gewerbekennzeichnung 00590 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | X | — |
| name1 00600 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00610 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00620 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00630 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 00640 | House number and supplement | string | X | — |
| landescode 00650 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00660 | City | string | X | — |
| ortsteil 00670 | District | string | X | — |
| postfach 00680 | PO box | string | X | — |
| postleitzahl 00690 | Postal code | string | X | — |
| strasse 00700 | Street | string | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00710 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| rollencodenummer 00720 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00730 | weiterverpflichtet | boolean | X | — |
| NETZNUTZUNGSVERTRAG [ ] * | — | object[] | Must | — |
| gemeinderabatt * 00740 | municipal discount for EDIFACT mapping. | integer | X | — |
| vertragsbeginn 00750 | Specifies when the contract begins. | string (date-time) | X | — |
| vertragsende 00760 | Specifies when the contract (is expected to) end or was ended. | string (date-time) | X | — |
| vertragskonditionen * | — | object | Must | — |
| haushaltskunde * 00770 | haushaltskunde | boolean | Must | — |
| naechstenetznutzungsabrechnung * 00780 | naechstenetznutzungsabrechnung | string | X | — |
| netznutzungsabrechnungIntervall * 00790 | netznutzungsabrechnungIntervall | integer | X | [504] |
| netznutzungsabrechnungsvariante * 00800 | Grid usage settlement variant | Enum Netznutzungsabrechnungsvariante | X | — |
ARBEITSPREIS_GRUNDPREIS | — | — | X | — |
ARBEITSPREIS_LEISTUNGSPREIS | — | — | X | — |
| netznutzungsvertrag * 00810 | Grid usage contract | Enum Netznutzungsvertrag | X | — |
KUNDEN_NB | — | — | X | — |
LIEFERANTEN_NB | — | — | X | — |
| netznutzungszahler * 00820 | Grid usage payer | Enum Netznutzungszahler | X | — |
KUNDE | — | — | X | — |
LIEFERANT | — | — | X | — |
| startAbrechnungsjahr 00830 | startAbrechnungsjahr | string (date-time) | X | — |
| netznutzungsabrechnung * | — | object | Must | — |
| abrechnungsZeitraum * 00840 | abrechnungsZeitraum | string | X | — |
| ZAEHLER [ ] | — | object[] | May | — |
| messlokationsId 00850 | messlokationsId | string | X | — |
| messwerterfassung 00860 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| zaehlergroesse 00870 | Meter size | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlernummer 00880 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 00890 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 00900 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 00910 | The number printed on the device, which is assigned by the MSB. | string | X | — |
| geraeteeigenschaften | — | object | May | — |
| geraetemerkmal 00920 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlwerke [ ] | — | object[] | May | — |
| bezeichnung 00930 | Additional designation, e.g. Zählwerk_Wirkarbeit. | string | Must | — |
| nachkommastelle 00940 | nachkommastelle | integer | Must | — |
| obisKennzahl 00950 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| vorkommastelle 00960 | vorkommastelle | integer | Must | — |
| wertegranularitaet 00970 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer * 00980 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| antwortstatus * 00990 | Response status / STS+E01 | string | X | — |
| antwortstatusCodeliste * 01000 | Response status code list / STS+E01 | string | X | — |
| dokumentennummer * 01010 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| freitext 01020 | Free text / FTX+ACB | string | X | — |
| kategorie * 01030 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 01040 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 01050 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 01060 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 01070 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| transaktionsgrundergaenzungBefristeteAnmeldung 01080 | Supplement to the transaction reason for temporary registrations/deregistrations / UTILMD STS+7++E01+ZW4+### | string | X | — |
| vertragsbeginn 01090 | Contract start date / DTM+92 | string (date-time) | X | — |
| vertragsende 01100 | Contract end date / DTM+93 | string (date-time) | X | — |
| vorgangsnummer * 01110 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 01120 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 01130 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 01140 | Email address | string | Must | — |
| nachname 01150 | Surname (family name) of the contact person | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 01160 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 01170 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 01180 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 01190 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 44014 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 G1.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0100070 | Registrations | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/ message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/ message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 33200150 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00160 | Information contact | — | X | — |
341200170 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800180 | Number / address | — | X | — |
3155 EM00190 | Electronic mail | — | X | [1P0..1] |
3155 FX00200 | Fax number | — | X | [1P0..1] |
3155 TE00210 | Telephone | — | X | [1P0..1] |
3155 AJ00220 | further telephone | — | X | [1P0..1] |
3155 AL00230 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00240 | Message recipient | — | X | — |
303900250 | MP-ID | — | X | — |
3055 900260 | GS1 | — | X | — |
3055 33200270 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400280 | Transaction | — | X | — |
740200290 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 9200300 | Contract start date | — | X | — |
238000310 | Date or time or time span, value | — | X | [UB2] |
2379 30300320 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.DTM | — | — | Must | [10] |
2005 9300330 | Contract end date | — | X | — |
238000340 | Date or time or time span, value | — | X | [UB2] |
2379 30300350 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.DTM | — | — | Must | [18] Should [28] ∧ [29] |
2005 15800360 | Start of balancing | — | X | — |
238000370 | Date or time or time span, value | — | X | [UB2] |
2379 30300380 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.DTM | — | — | Must | [28] ∧ [64] |
2005 15900390 | End of balancing | — | X | — |
238000400 | Date or time or time span, value | — | X | [UB2] |
2379 30300410 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.STS | — | — | Must | [2061] |
9015 700420 | Transaction reason | — | X | — |
9013 E0600430 | Replacement supply | — | X | [502] |
9013 Z0200440 | Contract termination of the supplier framework contract | — | X | — |
9013 Z3600450 | EoG due to move-in/move-out (relocation) | — | X | — |
9013 Z3700460 | EoG due to move-in to a new installation | — | X | — |
9013 Z3900470 | EoG due to temporary connection | — | X | — |
9013 ZC600480 | EoG due to balancing group closure | — | X | — |
9013 ZC700490 | EoG due to expiry of the allocation authorization | — | X | — |
9013 ZT600500 | EoG due to contract termination by LF | — | X | — |
9013 ZT700510 | EoG due to contract termination by the customer/LFN | — | X | — |
| SG4.STS | — | — | Should | [37] |
9015 Z1700520 | Transaction reason supplement for temporary registration | — | X | — |
9013 E0100530 | Move-in/move-out (relocation) | — | X | — |
9013 E0300540 | Change | — | X | — |
| SG4.STS | — | — | Must | [249] |
9015 E0100550 | Status of the response | — | X | — |
901300560 | Code of the check step | — | X | — |
1131 G_001300570 | Gas code list no. G_0013 | — | X | — |
| SG4.FTX | — | — | May | — |
4451 ACB00580 | Additional information (for general notes) | — | X | — |
444000590 | Text for general information | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 17200600 | Reporting point | — | X | — |
322500610 | Identifier | — | X | [953] |
| SG6.RFF | — | — | Must | — |
1153 Z1300620 | Check identifier | — | X | — |
1154 4401400630 | GeLi Gas / Confirmation EoG registration | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00640 | Transaction reference number | — | X | — |
115400650 | Transaction number | — | X | — |
| SG6.RFF | — | — | Must | [636] |
1153 Z1800660 | Market location | — | X | — |
115400670 | ID of the market location | — | X | [950] |
| SG6.DTM | — | — | Must | [19] |
2005 15500680 | Invoicing period, start date | — | X | — |
238000690 | Date or time or time span, value | — | X | [UB2] |
2379 30300700 | CCYYMMDDHHMMZZZ | — | X | — |
| SG6.DTM | — | — | Must | — |
2005 Z2000710 | Billing interval of the LF | — | X | — |
238000720 | Date or time or time span, value | — | X | — |
2379 80200730 | Month | — | X | — |
| SG6.DTM | — | — | Must | — |
2005 Z2100740 | Grid usage settlement date | — | X | — |
238000750 | Date or time or time span, value | — | X | — |
2379 10600760 | MMDD | — | X | — |
2379 10400770 | MMWW-MMWW | — | X | — |
| SG6.DTM | — | — | Must | [230] |
2005 Z0900780 | Next grid usage settlement | — | X | — |
238000790 | Date or time or time span, value | — | X | — |
2379 60200800 | CCYY | — | X | — |
| SG6.DTM | — | — | Must | — |
2005 Z2200810 | Grid usage settlement or feed-in remuneration interval of the NB | — | X | [504] |
238000820 | Date or time or time span, value | — | X | — |
2379 80200830 | Month | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0100840 | Data of the market location | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 3100850 | Estimated annual quantity total | — | X | — |
606000860 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH00870 | Kilowatt hour | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Y0200880 | Customer value | — | X | — |
606000890 | Quantity specification | — | X | [902] ∧ [907] |
6411 KWH00900 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1900910 | Balancing group | — | X | — |
703700920 | Balancing group | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2100930 | Market area | — | X | — |
703700940 | Market area | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Y0100950 | Pressure level of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Y0100960 | High pressure | — | X | — |
7111 Y0200970 | Medium pressure | — | X | — |
7111 Y0300980 | Low pressure | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZC000990 | Forecast based on values | — | X | — |
7037 ZA601000 | Forecast based on profiles | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z1501010 | Household customer pursuant to EnWG | — | X | — |
7037 Z1801020 | Not a household customer under EnWG | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z1701030 | Case group assignment according to GABi Gas | — | X | — |
1131 GABi-01040 | Nomination replacement proc | — | X | — |
1131 GABi-RLMmT01050 | RLM customer on daily regime - Exit | — | X | — |
1131 GABi-RLMoT01060 | RLM customer on hourly regime - Exit | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z8801070 | Grid usage | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z7401080 | Grid usage contract | — | X | — |
7110 Z0801090 | Direct contract between customer and NB | — | X | — |
7110 Z0901100 | Contract between supplier and NB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z7301110 | Payment of grid usage | — | X | — |
7110 Z1001120 | Customer | — | X | [216] |
7110 Z1101130 | Supplier | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZB101140 | Grid usage settlement variant | — | X | — |
7110 Z1401150 | Energy price/basic price | — | X | — |
7110 Z1501160 | Energy price/ demand price | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0201170 | OBIS data of the market location | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 501180 | Product identification | — | X | — |
714001190 | OBIS code of the market location | — | X | [315] |
7143 SRW01200 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401210 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD901220 | Annually | — | X | — |
7111 ZE801230 | Semi-annual | — | X | — |
7111 ZE901240 | Quarterly | — | X | — |
7111 ZB701250 | Monthly | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0701260 | Concession levy data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1001270 | OBIS code | — | X | — |
115401280 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z0801290 | Concession levy | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 KAS01300 | for all special provisions under concession agreements that are not integrated into the structure of the KAV | — | X | — |
7111 SA01310 | Special contract customers < 1 kV under § 2 (7) and > 1 kV, price under § 2 (3) (for electricity 0.11 ct/kWh and for gas 0.03 ct/kWh) | — | X | — |
7111 SAS01320 | Indication that a different price applies for special contract customers | — | X | — |
7111 TA01330 | Tariff customers, for electricity § 2. (2) 1b HT or ET (high KA) and for gas § 2 (2) 2b | — | X | — |
7111 TAS01340 | Indication that a different price applies for tariff customers | — | X | — |
7111 TK01350 | for gas under KAV § 2 (2) 2a where used exclusively for cooking and hot water generation | — | X | — |
7111 TKS01360 | Indication when a different price is to be used pursuant to KAV § 2 (2) 2a | — | X | — |
711001370 | Concession levy in euro/kWh | — | Must | [912] ∧ [902] [128] |
711001380 | Fee category of the concession levy | — | Should | [219] |
| SG8.SEQ | — | — | Must | — |
1229 Z1201390 | Municipal discount | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z1601400 | Municipal discount | — | X | — |
606001410 | Quantity | — | X | [902] ∧ [930] ∧ [938] |
6411 P101420 | Percent | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1801430 | Data of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1901440 | Metering location | — | X | — |
115401450 | ID of the metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 ZB301460 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9101470 | MSB | — | X | — |
113101480 | MP-ID | — | X | — |
7110 Z1901490 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2001500 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF001510 | gMSB | — | X | — |
113101520 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Y0201530 | Gas quality | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Y0401540 | H-gas | — | X | — |
7111 Y0501550 | L-gas | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0301560 | Metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1901570 | Metering location | — | X | — |
115401580 | ID of a metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 E1301590 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 NMG01600 | new measuring equipment gas according to MsbG | — | X | — |
7111 DKZ01610 | Rotary piston gas meter | — | X | — |
7111 BGZ01620 | Diaphragm gas meter | — | X | — |
7111 TRZ01630 | Turbine gas meter | — | X | — |
7111 UGZ01640 | Ultrasonic gas meter | — | X | — |
7111 WGZ01650 | Vortex gas meter | — | X | — |
7111 EHZ01660 | electronic household meter | — | X | — |
7111 IVA01670 | Individual reconciliation (special equipment) | — | X | — |
| SG10.CAV | — | — | Must | — |
7110 G1001680 | Gas meter G10 | — | X | — |
7110 G10001690 | Gas meter G100 | — | X | — |
7110 G100001700 | Gas meter G1000 | — | X | — |
7110 G1000001710 | Gas meter G10000 | — | X | — |
7110 G1250001720 | Gas meter G12500 | — | X | — |
7110 G1601730 | Gas meter G16 | — | X | — |
7110 G16001740 | Gas meter G160 | — | X | — |
7110 G160001750 | Gas meter G1600 | — | X | — |
7110 G1600001760 | Gas meter G16000 | — | X | — |
7110 G2.501770 | Gas meter G2.5 | — | X | — |
7110 G2501780 | Gas meter G25 | — | X | — |
7110 G25001790 | Gas meter G250 | — | X | — |
7110 G250001800 | Gas meter G2500 | — | X | — |
7110 G35001810 | Gas meter G350 | — | X | — |
7110 G401820 | Gas meter G4 | — | X | — |
7110 G4001830 | Gas meter G40 | — | X | — |
7110 G40001840 | Gas meter G400 | — | X | — |
7110 G400001850 | Gas meter G4000 | — | X | — |
7110 G601860 | Gas meter G6 | — | X | — |
7110 G6501870 | Gas meter G65 | — | X | — |
7110 G65001880 | Gas meter G650 | — | X | — |
7110 G650001890 | Gas meter G6500 | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001900 | Device number | — | X | — |
711001910 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1201920 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR01930 | remotely readable meters | — | X | — |
7111 MMR01940 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z5001950 | Measurement data recording device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1901960 | Metering location | — | X | — |
115401970 | ID of a metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 E1301980 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001990 | Device number | — | X | — |
711002000 | Device number | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0902010 | Volume corrector data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG02020 | Device number of the meter | — | X | — |
115402030 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6402040 | Volume corrector | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3002050 | Device number | — | X | — |
711002060 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 DMU02070 | Density volume converter | — | X | — |
7111 TMU02080 | Temperature volume converter | — | X | — |
7111 ZMU02090 | Volume conversion devic e | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2002100 | OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [655] |
1153 MG02110 | Device number of the meter | — | X | [442] |
1153 Z1102120 | Device number of the volume converter | — | X | — |
115402130 | Device number | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1902140 | Metering location | — | X | — |
115402150 | ID of a metering location | — | X | [951] |
| SG8.PIA | — | — | Must | — |
4347 502160 | Product identification | — | X | — |
714002170 | OBIS code of the metering device | — | X | [324] |
7143 SRW02180 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE402190 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD902200 | Annually | — | X | — |
7111 ZE802210 | Semi-annual | — | X | — |
7111 ZE902220 | Quarterly | — | X | — |
7111 ZB702230 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1102240 | Product | — | X | — |
7037 Z3302250 | Integer and decimal places of the register | — | X | — |
| SG10.CAV | — | — | Must | — |
711002260 | Digits before the decimal point | — | X | — |
711002270 | Digits after the decimal point | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6302280 | Local identifier for control purposes | — | X | — |
703602290 | Designation of the register on the device | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0502300 | Communication device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG02310 | Device number of the meter | — | X | — |
115402320 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2602330 | Communication device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3002340 | Device number | — | X | — |
711002350 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 GSM02360 | GSM/GPRS/UMTS- comm. dev. | — | X | — |
7111 ETH02370 | Ethernet comm. dev. LAN/WLAN | — | X | — |
7111 PLC02380 | PLC comm. device | — | X | — |
7111 PST02390 | Landline comm. dev. TAE | — | X | — |
7111 DSL02400 | DSL comm. dev. | — | X | — |
7111 LTE02410 | LTE comm. dev. | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1302420 | Smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7502430 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3002440 | Device number | — | X | — |
711002450 | Device number | — | X | [952] |
| SG8.SEQ | — | — | Must | — |
1229 Z3502460 | Load profile data | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1202470 | Load profile | — | X | — |
7037 E0102480 | synthetic method | — | X | — |
7037 Z1002490 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711102500 | Code of the load profile | — | X | — |
3055 8902510 | Assigned by the trader (here grid operator) | — | X | — |
3055 29302520 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z9902530 | Measuring station of the daily parameter (currently only the temperature is a permitted daily parameter) | — | X | — |
7059 ZA002540 | Climate zone of the daily parameter (currently is daily parameter) | — | X | — |
703702550 | ID of climate zone / temperature measuring point | — | X | — |
113102560 | Service provider | — | X | [58] |
3055 8902570 | Assigned by the trader (here grid operator) | — | X | — |
3055 29302580 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0902590 | Customer of the LF | — | X | — |
303602600 | Name | — | X | — |
3045 Z0102610 | Structure of person names | — | X | — |
3045 Z0202620 | Structure of the company name | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0402630 | Correspondence address of the customer of the LF | — | X | — |
303602640 | Name | — | X | — |
3045 Z0102650 | Structure of person names | — | X | — |
3045 Z0202660 | Structure of the company name | — | X | — |
304202670 | Street and house number or PO box | — | X | — |
316402680 | City | — | X | — |
325102690 | Postal code | — | — | M [268] S [166] |
320702700 | Country name, code | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 DP02710 | Supply address | — | X | — |
312402720 | Additional information for identification | — | — | — |
304202730 | Street and house number or PO box | — | — | S [166] M [212] |
316402740 | City | — | X | — |
325102750 | Postal code | — | X | — |
320702760 | Country name, code | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0502770 | Name and address for the meter reading card | — | X | — |
303602780 | Name | — | X | — |
3045 Z0102790 | Structure of person names | — | X | — |
3045 Z0202800 | Structure of the company name | — | X | — |
304202810 | Street and house number or PO box | — | X | — |
316402820 | City | — | X | — |
325102830 | Postal code | — | — | M [268] S [166] |
320702840 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1902850 | Metering location | — | X | — |
115402860 | ID of a metering location | — | X | [951] |
| UNT | — | — | Must | — |
007402870 | Number of segments in a message | — | X | — |
006202880 | Message reference number | — | X | — |
Conditions of this table
The free text of the 38 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDG.
| Marker | Condition |
|---|---|
| [10] | If SG4 STS+Z17 (transaction reason for fixed-term registration) is present |
| [18] | If SG4 DTM+93 (end as of) is not present |
| [19] | If SG8 SEQ+Z01 (data of the market location) SG10 CCI+++ZC0 (forecast based on values) present |
| [28] | If SG4 DTM+93 (end as of) is present |
| [29] | If balancing takes place |
| [37] | If the registration/change is limited in time |
| [58] | If in this CCI the DE3055 with the code 293 is present |
| [64] | If SG4 DTM+158 (start of balancing) is present |
| [128] | If SG10 CAV+TAS/TKS/SAS/KAS present |
| [166] | If present |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [216] | If CCI+++Z88 (grid usage) CAV+Z74:::Z08 (grid usage contract: direct contract between customer and NB) present |
| [219] | If present at the market location |
| [230] | Resulting date or end date of the cycle period from DTM+Z21 (date of the grid usage settlement) and DTM+Z09 (next grid usage settlement) must be >= DTM+92 (start on) |
| [249] | Within one SG4 IDE, all DE1131 of the SG4 STS+E01 must contain the identical value |
| [268] | If an "X" is listed for the code in DE3207 in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| [315] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 4, that are required at the market location must be stated; the minimum scope from chapter 4.6 must be observed. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.2 of the document "Code list of configurations" |
| [324] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes chapter 4. that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.2 of the document "Code list of configurations" |
| [442] | If the device number of the meter named in this RFF DE1154 is present in no SG8+SEQ+Z09 volume converter data in the RFF+MG (reference to the device number) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [502] | Note: Replacement supply exists only for - market locations at the low pressure level that are not household customers as defined by the EnWG and that are no longer subject to statutory substitute supply (three months) and - for market locations that are to be supplied at medium pressure. The basis for a replacement supply is the bilateral agreement. |
| [504] | Note: Code Z22 is also used in the electricity division. The reference to the feed-in tariff interval is not relevant in the gas division. |
| [636] | Note: Using a code in DE1153, this RFF classifies the DTM contained in the same segment group as content relevant to a market location or metering location |
| [655] | Note: If a meter is connected to a volume corrector, no OBIS code numbers are stated at the meter Here there are only OBIS code numbers from the volume corrector |
| [902] | Format: Possible value: ≥ 0 |
| [907] | Format: max. 4 decimal places |
| [912] | Format: max. 6 decimal places |
| [930] | Format: max. 2 decimal places |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [938] | Format: Possible value: <= 10 |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [953] | Format: market location ID or metering point identifier |
| [2061] | Segment or segment group must be specified exactly once per SG4 IDE (transaction) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [UB2] | ([931] ∧ [934] [490]) ⊻ ([931] ∧ [935] [491]) |
Example message
UNA:+.? '
UNB+UNOC:3+9800044300007:502+9870013800007:502+{{date}}:{{time}}+211739'
UNH+934676+UTILMD:D:11A:UN:G1.1'
BGM+E01+934676BGM'
DTM+137:202604010624?+00:303'
NAD+MS+9800044300007::332'
NAD+MR+9870013800007::332'
IDE+24+1023759574'
DTM+92:202406010400?+00:303'
DTM+93:202407010400?+00:303'
DTM+158:202406010400?+00:303'
DTM+159:202407010400?+00:303'
STS+7++E06'
STS+Z17++E03'
STS+E01++E15:G_0013'
FTX+ACB+++ABC123456'
LOC+172+50812938303'
LOC+172+DE7003318063400000000000090936184'
RFF+Z13:44014'
RFF+TN:ABC123456'
RFF+Z18:50812938303'
DTM+Z20:12:802'
DTM+Z21:0101:106'
DTM+Z09:2025:602'
DTM+Z22:12:802'
SEQ+Z01'
QTY+31:50000:KWH'
QTY+Y02:123.123:KWH'
CCI+Z19++11Y0-0000-0076-N'
CCI+Z21++11YR00000002596Z'
CCI+++Y01'
CAV+Y03'
CCI+++ZA6'
CCI+++Z15'
CCI+++Z88'
CAV+Z74:::Z09'
CAV+Z73:::Z11'
CAV+ZB1:::Z14'
SEQ+Z02'
PIA+5+7-0?:33.86.0:SRW'
CCI+++ZE4'
CAV+ZD9'
SEQ+Z07'
RFF+Z10:7-0?:33.86.0'
CCI+++Z08'
CAV+SA'
SEQ+Z12'
QTY+Z16:0:P1'
SEQ+Z18'
RFF+Z19:DE7003318063400000000000090936184'
CCI+++ZB3'
CAV+Z91:9800110000002::Z19'
CAV+ZF0:9800110000002'
CCI+++Y02'
CAV+Y04'
SEQ+Z03'
RFF+Z19:DE7003318063400000000000090936184'
CCI+++E13'
CAV+BGZ'
CAV+:::G4'
CAV+Z30:::ABC123456'
CCI+++E12'
CAV+MMR'
SEQ+Z50'
RFF+Z19:DE7003318063400000000000090936184'
CCI+++E13'
CAV+Z30:::XYZ123456'
SEQ+Z09'
RFF+MG:ABC123456'
CCI+++Z64'
CAV+Z30:::MMM123456'
CAV+DMU'
SEQ+Z20'
RFF+Z11:MMM123456'
RFF+Z19:DE7003318063400000000000090936184'
PIA+5+7-0?:3.0.0:SRW'
CCI+++ZE4'
CAV+ZD9'
CCI+11++Z33'
CAV+:::5:3'
SEQ+Z05'
RFF+MG:ABC123456'
CCI+++Z26'
CAV+Z30:::PPP123456'
CAV+LTE'
SEQ+Z35'
CCI+Z12++Z10'
CAV+N14::293'
CCI+Z99++1234:ZT1:293'
NAD+Z09+++Mustermann:::::Z01'
NAD+Z04+++Mustermann:::::Z01+Str.::1+Ort++12345+DE'
NAD+DP++Mustermann++Str.::1+Ort++12345+DE'
NAD+Z05+++Mustermann:::::Z01+Str.::1+Ort++12345+DE'
RFF+Z19:DE7003318063400000000000090936184'
UNT+93+934676'
UNZ+1+211739'[1 item
{6 fields
"data": {3 fields
"stammdaten": {6 fields
"MARKTLOKATION": [1 item
{8 fields
"lokationsadresse": {6 fields
"zusatzInformation": {1 field
"zaehlwerke": [1 item
{3 fields
"konzessionsabgabe": {1 field
"MESSLOKATION": [1 item
{7 fields
"ablesekartenempfaenger": {6 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {5 fields
"marktrollen": [2 items
{5 fields
{4 fields
"NETZNUTZUNGSVERTRAG": [1 item
{10 fields
"vertragskonditionen": {7 fields
"netznutzungsabrechnung": {1 field
"ENERGIELIEFERVERTRAG": [1 item
{9 fields
"vertragspartner2": [1 item
{5 fields
"geschaeftspartnerrolle": [1 item
"vertragskonditionen": {1 field
"korrespondenzpartner": {5 fields
"partneradresse": {5 fields
"ZAEHLER": [1 item
{10 fields
"zaehlwerke": [1 item
{4 fields
"geraete": [3 items
{2 fields
"geraeteeigenschaften": {1 field
{2 fields
"geraeteeigenschaften": {2 fields
{2 fields
"geraeteeigenschaften": {2 fields
"BILANZIERUNG": [1 item
{10 fields
"lastprofile": [1 item
{6 fields
"tagesparameter": {3 fields
"bilanzkreise": [1 item
{1 field
"jahresverbrauchsprognose": {2 fields
"kundenwert": {1 field
"transaktionsdaten": {18 fields
"absender": {4 fields
"empfaenger": {4 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF and NB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Start of replacement supply / default supply | GeLi Gas 2.0 | Gas | Step 2 |
| NB | NB | Start of replacement supply / default supply | GeLi Gas 2.0 | Gas | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Confirmation of EoG registration |
| AHB | UTILMD AHB gas |
| Decision tree | E_3008 |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GeLi Gas 2.0 | Start of the replacement supply / default supply | LF (corresponds to E/G) → NB | Response to registration for E/G |
| GeLi Gas | Ch. C 2.3 No. 4a | E/G → NB | Notification by the E/G whether and, if applicable, for which time period the market location is to be assigned to substitute supply or basic supply. |
One entry from format version 202610
The check identifiers table of format version 202604 does not carry this entry: decision tree. It comes from version 202610. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202604.
Transaction and responses
Role of this check identifier: response — confirmation. Basis: the transaction data carry antwortstatus and antwortstatusCodeliste; the title or the action of the Prüfi table begins with “response”; the title names a polarity (confirmation).
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 44013 | Registration EoG | UTILMD_GAS | from the step sequence |
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfragereferenznummer | SG4.IDE+24.SG6.RFF+TN | vorgangsnummer |
For RFF+TN, the field description of the time slice names the »reference transaction number (from request message)« — the target is the vorgangsnummer in segment SG4.IDE+24 of the request. Measured: 44013 carries vorgangsnummer in SG4.IDE+24.
Response codes
Decision trees: G_0013 · E_3008.
The Prüfi table names one further tree across all rows of this check identifier. They tie it to a process, not to a row of its handbook — their codes are therefore only on the respective tree page. For G_0013 there is no decision tree in version 202604; its response codes are therefore not given here.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDG has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 388 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type utilmdGas. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.