Check identifier 44060 — Response to the business data request
Check identifier 44060 · EDIFACT message type UTILMD_GAS · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 44060 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| gasqualitaet * 00010 | gasqualitaet for EDIFACT mapping | Enum Gasqualitaet | Must | — |
H_GAS | — | — | Must | — |
L_GAS | — | — | Must | — |
| messlokationsId * 00020 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| marktrollen [ ] * | — | object[] | Must | — |
| marktrolle 00030 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| rollencodenummer * 00040 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet * 00050 | weiterverpflichtet | boolean | X | — |
| messadresse | — | object | May | — |
| hausnummer 00060 | House number and supplement | string | X | — |
| landescode 00070 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00080 | City | string | X | — |
| ortsteil 00090 | District | string | X | — |
| postfach 00100 | PO box | string | X | — |
| postleitzahl 00110 | Postal code | string | X | — |
| strasse 00120 | Street | string | X | — |
| zusatzInformation | — | object | May | — |
| zusatz1 00130 | Address supplement 1 | string | X | — |
| zusatz2 00140 | Address supplement 2 | string | X | — |
| zusatz3 00150 | Address supplement 3 | string | X | — |
| zusatz4 00160 | Address supplement 4 | string | X | — |
| zusatz5 00170 | Address supplement 5 | string | X | — |
| zaehlwerke [ ] * | — | object[] | Must | — |
| messprodukt * 00180 | messprodukt | string | X | — |
| MESSSTELLENBETRIEBSVERTRAG [ ] * | — | object[] | Must | — |
| lokationsId * 00190 | lokationsId | string | X | — |
| lokationsTyp * 00200 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | X | — |
MALO | — | — | X | — |
MELO | — | — | X | — |
NELO | — | — | X | — |
TECHNISCHE_RESSOURCE | — | — | X | — |
STEUERBARE_RESSOURCE | — | — | X | — |
TRANCHE | — | — | X | — |
MABIS_ZAEHLPUNKT | — | — | X | — |
| vertragskonditionen * | — | object | Must | — |
| geplanteTurnusablesung * | — | object | Must | — |
| ableseZeitraum * 00210 | ableseZeitraum | string | X | — |
| ZAEHLER [ ] | — | object[] | May | — |
| befestigungsart 00220 | Mounting type | Enum Befestigungsart | Must | — |
STECKTECHNIK | — | — | Must | — |
DREIPUNKT | — | — | Must | — |
HUTSCHIENE | — | — | Must | — |
EINSTUTZEN | — | — | Must | — |
ZWEISTUTZEN | — | — | Must | — |
| messlokationsId 00230 | messlokationsId | string | X | — |
| messwerterfassung 00240 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| volumenerfassung 00250 | Volume measurement | Enum Volumenerfassung | X | — |
HOCHFREQUENZSONDE | — | — | X | — |
KENNLINIENKORREKTUR | — | — | X | — |
SCHLEICHMENGENUNTERDRUECKUNG | — | — | X | — |
| zaehlergroesse 00260 | Meter size | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlernummer 00270 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 00280 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 00290 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 00300 | The number printed on the device, which is assigned by the MSB. | string | X | — |
| geraeteeigenschaften | — | object | May | — |
| geraetemerkmal 00310 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| volumenerfassung 00320 | Volume measurement | Enum Volumenerfassung | X | — |
HOCHFREQUENZSONDE | — | — | X | — |
KENNLINIENKORREKTUR | — | — | X | — |
SCHLEICHMENGENUNTERDRUECKUNG | — | — | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| bezeichnung 00330 | Additional designation, e.g. Zählwerk_Wirkarbeit. | string | Must | — |
| nachkommastelle 00340 | nachkommastelle | integer | Must | — |
| obisKennzahl 00350 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| vorkommastelle 00360 | vorkommastelle | integer | Must | — |
| wertegranularitaet 00370 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer * 00380 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| dokumentennummer * 00390 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| kategorie * 00400 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 00410 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00420 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00430 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 00440 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vorgangsnummer * 00450 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00460 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00470 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00480 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00490 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 44060 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 G1.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z1400070 | Master data of the market or metering location | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 33200150 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00160 | Message recipient | — | X | — |
303900170 | MP-ID | — | X | — |
3055 900180 | GS1 | — | X | — |
3055 33200190 | DE, DVGW Service & Consult GmbH | — | X | — |
3055 29300200 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400210 | Transaction | — | X | — |
740200220 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | [2061] |
9015 700230 | Transaction reason | — | X | — |
9013 Z4000240 | Business data request | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 17200250 | Reporting point | — | X | — |
322500260 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300270 | Check identifier | — | X | — |
1154 4406000280 | WiM gas / response to the MSB business data request | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 AAV00290 | Number of the request | — | X | — |
115400300 | Transaction number | — | X | — |
| SG6.RFF | — | — | Must | [636] |
1153 Z1900310 | Metering location | — | X | — |
115400320 | ID of the metering location | — | X | [951] |
| SG6.DTM | — | — | Must | — |
2005 75200330 | Periodic meter reading | — | X | — |
238000340 | Date or time or time span, value | — | X | — |
2379 10400350 | MMWW-MMWW | — | X | — |
2379 10600360 | MMDD | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1800370 | Data of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1900380 | Metering location | — | X | — |
115400390 | ID of the metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 ZB300400 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9100410 | MSB | — | X | — |
113100420 | MP-ID | — | X | — |
7110 Z1900430 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2000440 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF000450 | gMSB | — | X | — |
113100460 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Y0200470 | Gas quality | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Y0400480 | H-gas | — | X | — |
7111 Y0500490 | L-gas | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1900500 | Required product of the metering location | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 500510 | Product identification | — | X | — |
714000520 | Metering product code | — | X | [427] |
7143 Z1100530 | Product | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0300540 | Metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1900550 | Metering location | — | X | — |
115400560 | ID of a metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 E1300570 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 NMG00580 | new measuring equipment gas according to MsbG | — | X | — |
7111 DKZ00590 | Rotary piston gas meter | — | X | — |
7111 BGZ00600 | Diaphragm gas meter | — | X | — |
7111 TRZ00610 | Turbine gas meter | — | X | — |
7111 UGZ00620 | Ultrasonic gas meter | — | X | — |
7111 WGZ00630 | Vortex gas meter | — | X | — |
7111 EHZ00640 | electronic household meter | — | X | — |
7111 IVA00650 | Individual reconciliation (special equipment) | — | X | — |
| SG10.CAV | — | — | Must | — |
7110 G1000660 | Gas meter G10 | — | X | — |
7110 G10000670 | Gas meter G100 | — | X | — |
7110 G100000680 | Gas meter G1000 | — | X | — |
7110 G1000000690 | Gas meter G10000 | — | X | — |
7110 G1250000700 | Gas meter G12500 | — | X | — |
7110 G1600710 | Gas meter G16 | — | X | — |
7110 G16000720 | Gas meter G160 | — | X | — |
7110 G160000730 | Gas meter G1600 | — | X | — |
7110 G1600000740 | Gas meter G16000 | — | X | — |
7110 G2.500750 | Gas meter G2.5 | — | X | — |
7110 G2500760 | Gas meter G25 | — | X | — |
7110 G25000770 | Gas meter G250 | — | X | — |
7110 G250000780 | Gas meter G2500 | — | X | — |
7110 G35000790 | Gas meter G350 | — | X | — |
7110 G400800 | Gas meter G4 | — | X | — |
7110 G4000810 | Gas meter G40 | — | X | — |
7110 G40000820 | Gas meter G400 | — | X | — |
7110 G400000830 | Gas meter G4000 | — | X | — |
7110 G600840 | Gas meter G6 | — | X | — |
7110 G6500850 | Gas meter G65 | — | X | — |
7110 G65000860 | Gas meter G650 | — | X | — |
7110 G650000870 | Gas meter G6500 | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3000880 | Device number | — | X | — |
711000890 | Device number | — | X | — |
| SG10.CAV | — | — | Should | [166] |
7111 ZC000900 | Type of volume measurement | — | X | — |
7110 Z1600910 | High-frequency probe | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2800920 | Mounting type metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3100930 | Single-connection meter | — | X | — |
7111 Z3200940 | Two-connection meter | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1200950 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR00960 | remotely readable meters | — | X | — |
7111 MMR00970 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z5000980 | Measurement data recording device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1900990 | Metering location | — | X | — |
115401000 | ID of a metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 E1301010 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001020 | Device number | — | X | — |
711001030 | Device number | — | X | — |
| SG10.CAV | — | — | Should | [166] |
7111 ZC001040 | Type of volume measurement | — | X | — |
7110 Z1601050 | High-frequency probe | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0901060 | Volume corrector data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG01070 | Device number of the meter | — | X | — |
115401080 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6401090 | Volume corrector | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001100 | Device number | — | X | — |
711001110 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 DMU01120 | Density volume converter | — | X | — |
7111 TMU01130 | Temperature volume converter | — | X | — |
7111 ZMU01140 | Volume conversion device | — | X | — |
| SG10.CAV | — | — | Should | [166] |
7111 ZC001150 | Type of volume measurement | — | X | — |
7110 Z1701160 | Characteristic curve correction | — | X | — |
7110 Z1801170 | Creep flow suppression | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2001180 | OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [655] |
1153 MG01190 | Device number of the meter | — | X | [442] |
1153 Z1101200 | Device number of the volume converter | — | X | — |
115401210 | Device number | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1901220 | Metering location | — | X | — |
115401230 | ID of a metering location | — | X | [951] |
| SG8.PIA | — | — | Must | — |
4347 501240 | Product identification | — | X | — |
714001250 | OBIS code of the metering device | — | X | [324] |
7143 SRW01260 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401270 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD901280 | Annually | — | X | — |
7111 ZE801290 | Semi-annual | — | X | — |
7111 ZE901300 | Quarterly | — | X | — |
7111 ZB701310 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1101320 | Product | — | X | — |
7037 Z3301330 | Integer and decimal places of the register | — | X | — |
| SG10.CAV | — | — | Must | — |
711001340 | Digits before the decimal point | — | X | — |
711001350 | Digits after the decimal point | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6301360 | Local identifier for control purposes | — | X | — |
703601370 | Designation of the register on the device | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0501380 | Communication device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG01390 | Device number of the meter | — | X | — |
115401400 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2601410 | Communication device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001420 | Device number | — | X | — |
711001430 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 GSM01440 | GSM/GPRS/UMTS comm. dev. | — | X | — |
7111 ETH01450 | Ethernet comm. dev. LAN/WLAN | — | X | — |
7111 PLC01460 | PLC comm. device | — | X | — |
7111 PST01470 | Landline comm. dev. TAE | — | X | — |
7111 DSL01480 | DSL comm. dev. | — | X | — |
7111 LTE01490 | LTE comm. dev. | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1301500 | Smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7501510 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001520 | Device number | — | X | — |
711001530 | Device number | — | X | [952] |
| SG12.NAD | — | — | Must | — |
3035 Z0301540 | Metering location address | — | X | — |
312401550 | Additional information for identification | — | — | — |
304201560 | Street and house number or PO box | — | — | S [166] M [212] |
316401570 | City | — | X | — |
325101580 | Postal code | — | X | — |
320701590 | Country name, code | — | X | — |
| UNT | — | — | Must | — |
007401600 | Number of segments in a message | — | X | — |
006201610 | Message reference number | — | X | — |
Conditions of this table
The free text of the 12 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDG.
| Marker | Condition |
|---|---|
| [166] | If present |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [324] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes chapter 4. that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.2 of the document "Code list of configurations" |
| [427] | Metering product code from chapter 3 "Code list of the standard metering products gas" of the code list of configurations |
| [442] | If the device number of the meter named in this RFF DE1154 is present in no SG8+SEQ+Z09 volume converter data in the RFF+MG (reference to the device number) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [636] | Note: Using a code in DE1153, this RFF classifies the DTM contained in the same segment group as content relevant to a market location or metering location |
| [655] | Note: If a meter is connected to a volume corrector, no OBIS code numbers are stated at the meter Here there are only OBIS code numbers from the volume corrector |
| [931] | Format: ZZZ = +00 |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [2061] | Segment or segment group must be specified exactly once per SG4 IDE (transaction) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | NB | Business data request from the MSB to NB | GeLi Gas 2.0 | Gas | Step 2 |
| MSB | MSB | Business data request from the MSB to NB | GeLi Gas 2.0 | Gas | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response to the business data request |
| AHB | UTILMD AHB gas |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GeLi Gas 2.0 | Business data request from MSB to NB | NB → MSB (electricity / gas) | Response |
| GeLi Gas | Ch. D 3.3 No. 2 | NB → MSB | Response |
Transaction and responses
Role of this check identifier: response. Basis: the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 17126 | Request for master data of metering location (gas) | ORDERS | from the step sequence |
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfragereferenznummer | SG4.IDE+24.SG6.RFF+AAV | dokumentennummer |
RFF+AAV quotes the preceding message via its BGM; the target is the dokumentennummer of the request. Measured: 17126 carries dokumentennummer in BGM+Z62.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDG has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 223 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
No test case exists for this check identifier in the test data of the format version. There is therefore no example message here — not even a reconstructed one: on a page that promises evidence, an invented message would be worse than none.