Check identifier 44018 — Rejection of contract termination
Check identifier 44018 · EDIFACT message type UTILMD_GAS · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 44018 | Condition |
|---|---|---|---|---|
| stammdaten | — | object | May | — |
| ENERGIELIEFERVERTRAG [ ] | — | object[] | May | — |
| vertragskonditionen | — | object | May | — |
| kuendigungstermin 00010 | kuendigungstermin | string | X | — |
| kuendigungsfrist | — | object | May | — |
| zeitraumText 00020 | zeitraumText | string | X | — |
| MARKTLOKATION [ ] | — | object[] | May | — |
| marktlokationsId 00030 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer * 00040 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| antwortstatus * 00050 | Response status / STS+E01 | string | X | — |
| antwortstatusCodeliste * 00060 | Response status code list / STS+E01 | string | X | — |
| datumKuendigungKd 00070 | Termination date communicated to the customer / DTM+Z05 | string (date-time) | Must | [15] Should [17] ∧ [16] |
| datumKuendigungLf 00080 | Termination date communicated to the supplier / DTM+Z06 | string (date-time) | Must | [15] Should [17] ∧ [16] |
| dokumentennummer * 00090 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| freitext 00100 | Free text / FTX+ACB | string | X | — |
| gueltigAb 00110 | Effective date/time / DTM+7 | string (date-time) | X | — |
| kategorie * 00120 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 00130 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00140 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00150 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 00160 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vorgangsnummer * 00170 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00180 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00190 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00200 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00210 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 44018 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 G1.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E3500070 | Contract termination | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 33200150 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00160 | Message recipient | — | X | — |
303900170 | MP-ID | — | X | — |
3055 900180 | GS1 | — | X | — |
3055 33200190 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400200 | Transaction | — | X | — |
740200210 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | [15] Should [17] ∧ [16] |
2005 Z0500220 | termination date confirmed to the customer | — | X | — |
2005 Z0600230 | termination date confirmed to the supplier | — | X | — |
238000240 | Date or time or time span, value | — | X | [UB2] |
2379 30300250 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.DTM | — | — | Must | [16] ∧ [581] |
2005 15700260 | Validity, start date | — | X | — |
238000270 | Date or time or time span, value | — | X | [UB2] |
2379 30300280 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.DTM | — | — | Must | [16] |
2005 Z0100290 | Notice period | — | X | — |
238000300 | Date or time or time span, value | — | X | — |
2379 Z0100310 | ZZRB | — | X | — |
| SG4.DTM | — | — | Must | [35] |
2005 Z1000320 | Termination effective date | — | X | — |
238000330 | Date or time or time span, value | — | X | [UB2] ∧ [209] |
2379 10600340 | MMDD | — | X | — |
2379 30300350 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.STS | — | — | Must | [2061] |
9015 700360 | Transaction reason | — | X | — |
9013 E0300370 | Change | — | X | — |
| SG4.STS | — | — | Must | [249] |
9015 E0100380 | Status of the response | — | X | — |
901300390 | Code of the check step | — | X | — |
1131 G_000500400 | Gas code list no. G_0005 | — | X | — |
| SG4.FTX | — | — | Must | [48] |
4451 ACB00410 | Additional information (for general notes) | — | X | — |
444000420 | Text for general information | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 17200430 | Reporting point | — | X | — |
322500440 | Identifier | — | X | [950] |
| SG6.RFF | — | — | Must | — |
1153 Z1300450 | Check identifier | — | X | — |
1154 4401800460 | GeLi Gas / rejection of contract termination | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00470 | Transaction reference number | — | X | — |
115400480 | Transaction number | — | X | — |
| UNT | — | — | Must | — |
007400490 | Number of segments in a message | — | X | — |
006200500 | Message reference number | — | X | — |
Conditions of this table
The free text of the 13 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDG.
| Marker | Condition |
|---|---|
| [15] | If SG4 STS+E01++Z34 (status of the response: rejection multiple termination) is present |
| [16] | If SG4 STS+E01++Z12 (status of the response: rejection contractual commitment) is present |
| [17] | If a confirmed contract termination by the customer or MP is already present |
| [35] | If the DE2380 of SG4 DTM+Z01 (notice period of the contract) contains T (date) in the fourth position |
| [48] | If the STS+E01++E14 (status of the response: rejection other) is present in this SG4 |
| [209] | If code 303 is present in DE2379 in the same segment |
| [249] | Within one SG4 IDE, all DE1131 of the SG4 STS+E01 must contain the identical value |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [581] | Note: The next possible contract termination date must be specified |
| [931] | Format: ZZZ = +00 |
| [950] | Format: market location ID |
| [2061] | Segment or segment group must be specified exactly once per SG4 IDE (transaction) |
| [UB2] | ([931] ∧ [934] [490]) ⊻ ([931] ∧ [935] [491]) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected is LF.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LFA | Contract termination | GeLi Gas 2.0 | Gas | Step 2 |
| LF | LFN | Contract termination | GeLi Gas 2.0 | Gas | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Rejection contract termination |
| AHB | UTILMD AHB gas |
| Decision tree | E_3001 |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GeLi Gas 2.0 | Contract termination | LF (corresponds to LFA) → LF (corresponds to LFN) | Response |
| GeLi Gas | Ch. B 1.3 No. 3a | LFA → LFN | Rejection of the contract termination |
Transaction and responses
Role of this check identifier: response — rejection. Basis: the transaction data carry antwortstatus and antwortstatusCodeliste; the title or the action of the Prüfi table begins with “response”; the title names a polarity (rejection).
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 44016 | Contract termination at the old supplier | UTILMD_GAS | from the step sequence |
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfragereferenznummer | SG4.IDE+24.SG6.RFF+TN | vorgangsnummer |
For RFF+TN, the field description of the time slice names the »reference transaction number (from request message)« — the target is the vorgangsnummer in segment SG4.IDE+24 of the request. Measured: 44016 carries vorgangsnummer in SG4.IDE+24.
Response codes
Decision trees: G_0005 · E_3001.
The Prüfi table names one further tree across all rows of this check identifier. They tie it to a process, not to a row of its handbook — their codes are therefore only on the respective tree page. For G_0005 there is no decision tree in version 202610; its response codes are therefore not given here.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDG has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 67 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
No test case exists for this check identifier in the test data of the format version. There is therefore no example message here — not even a reconstructed one: on a page that promises evidence, an invented message would be worse than none.