Check identifier 44170 — Rejection of commitment request
Check identifier 44170 · EDIFACT message type UTILMD_GAS · Format version 202604
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 44170 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 G1.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0100070 | Registrations | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/ message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/ message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 33200150 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00160 | Information contact | — | X | — |
341200170 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800180 | Number / address | — | X | — |
3155 EM00190 | Electronic mail | — | X | [1P0..1] |
3155 FX00200 | Fax number | — | X | [1P0..1] |
3155 TE00210 | Telephone | — | X | [1P0..1] |
3155 AJ00220 | further telephone | — | X | [1P0..1] |
3155 AL00230 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00240 | Message recipient | — | X | — |
303900250 | MP-ID | — | X | — |
3055 900260 | GS1 | — | X | — |
3055 33200270 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400280 | Transaction | — | X | — |
740200290 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | [2061] |
9015 700300 | Transaction reason | — | X | — |
9013 E0100310 | Move-in/move-out (relocation) | — | X | — |
9013 E0200320 | Move-in to creation | — | X | — |
9013 E0300330 | Change | — | X | — |
| SG4.STS | — | — | Must | [249] |
9015 E0100340 | Status of the response | — | X | — |
901300350 | Code of the check step | — | X | — |
1131 G_007100360 | Gas code list no. G_0071 | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 17200370 | Reporting point | — | X | — |
322500380 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300390 | Check identifier | — | X | — |
1154 4417000400 | WiM gas / rejection of commitment request | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00410 | Transaction reference number | — | X | — |
115400420 | Transaction number | — | X | — |
| UNT | — | — | Must | — |
007400430 | Number of segments in a message | — | X | — |
006200440 | Message reference number | — | X | — |
Conditions of this table
The free text of the 6 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDG.
| Marker | Condition |
|---|---|
| [249] | Within one SG4 IDE, all DE1131 of the SG4 STS+E01 must contain the identical value |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [931] | Format: ZZZ = +00 |
| [951] | Format: Metering point identifier |
| [2061] | Segment or segment group must be specified exactly once per SG4 IDE (transaction) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Belongs to these role views
There is no role view for this check identifier: in this format version no process step of any market role carries it. A role statement would stand here without evidence.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Rejection commitment request |
| AHB | UTILMD AHB gas |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM gas | Ch. B 4.3 No. 8 | gMSB → NB | In the case of step 6: confirmation of the takeover of the individual metering location by the gMSB |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 58 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.