Check identifier 44014 — Confirmation of EoG registration
Check identifier 44014 · EDIFACT message type UTILMD_GAS · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 44014 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| BILANZIERUNG [ ] * | — | object[] | Must | — |
| bilanzierungsbeginn 00010 | Inclusive start of the balancing | string (date-time) | X | — |
| bilanzierungsende 00020 | Exclusive end of balancing | string (date-time) | X | — |
| fallgruppenzuordnung 00030 | Case group assignment (for gas RLM) | Enum Fallgruppenzuordnung | Must | — |
GABI_RLMmT | — | — | Must | — |
GABI_RLMoT | — | — | Must | — |
GABI_RLMNEV | — | — | Must | — |
| prognosegrundlage * 00040 | Forecast basis | Enum Prognosegrundlage | Must | — |
WERTE | — | — | Must | — |
PROFILE | — | — | Must | — |
| bilanzkreise [ ] | — | object[] | May | — |
| bezeichnung 00050 | External designation | string | X | — |
| jahresverbrauchsprognose | — | object | May | — |
| einheit 00060 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 00070 | Value | number (float) | X | — |
| kundenwert | — | object | May | — |
| wert 00080 | Value | number (float) | X | — |
| lastprofile [ ] | — | object[] | May | — |
| bezeichnung 00090 | Designation of the profile | string | Must | — |
| herausgeber 00100 | Issuer of the load profile | string | Must | — |
| verfahren 00110 | Profiling method | Enum Profilverfahren | X | — |
SYNTHETISCH | — | — | X | — |
ANALYTISCH | — | — | X | — |
| tagesparameter | — | object | May | — |
| dienstanbieter 00120 | dienstanbieter | string | Must | — |
| herausgeber 00130 | Herausgeber | Enum Herausgeber | Must | — |
NB | — | — | Must | — |
BDEW | — | — | Must | — |
TUM | — | — | Must | — |
| klimazone 00140 | klimazone | string | Must | — |
| temperaturmessstelle 00150 | temperaturmessstelle | string | Must | — |
| ENERGIELIEFERVERTRAG [ ] * | — | object[] | Must | — |
| korrespondenzpartner | — | object | May | — |
| anrede 00160 | The form of address for the GePa, e.g. Mr. | string | X | — |
| gewerbekennzeichnung 00170 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | X | — |
| name1 00180 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00190 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00200 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00210 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 00220 | House number and supplement | string | X | — |
| landescode 00230 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00240 | City | string | X | — |
| ortsteil 00250 | District | string | X | — |
| postfach 00260 | PO box | string | X | — |
| postleitzahl 00270 | Postal code | string | X | — |
| strasse 00280 | Street | string | X | — |
| vertragskonditionen * | — | object | Must | — |
| abrechnungsintervall * 00290 | abrechnungsintervall | integer | X | — |
| vertragspartner2 [ ] | — | object[] | May | — |
| anrede 00300 | The form of address for the GePa, e.g. Mr. | string | X | — |
| gewerbekennzeichnung 00310 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | X | — |
| name1 00320 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00330 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00340 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00350 | name4 | string | X | — |
| MARKTLOKATION [ ] * | — | object[] | Must | — |
| marktgebiet * 00360 | for EDIFACT mapping | string | X | — |
| marktlokationsId * 00370 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| netzebene * 00380 | Grid level at which the energy is drawn. For electricity, the voltage level of the supply; for gas, the pressure level. Example electricity: low voltage Example gas: low pressure. | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| lokationsadresse | — | object | May | — |
| hausnummer 00390 | House number and supplement | string | X | — |
| landescode 00400 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00410 | City | string | X | — |
| ortsteil 00420 | District | string | X | — |
| postfach 00430 | PO box | string | X | — |
| postleitzahl 00440 | Postal code | string | X | — |
| strasse 00450 | Street | string | X | — |
| zusatzInformation | — | object | May | — |
| zusatz1 00460 | Address supplement 1 | string | X | — |
| zusatz2 00470 | Address supplement 2 | string | X | — |
| zusatz3 00480 | Address supplement 3 | string | X | — |
| zusatz4 00490 | Address supplement 4 | string | X | — |
| zusatz5 00500 | Address supplement 5 | string | X | — |
| zaehlwerke [ ] * | — | object[] | Must | — |
| obisKennzahl * 00510 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| wertegranularitaet 00520 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| konzessionsabgabe | — | object | May | — |
| kategorie 00530 | Category | string | Must | — |
| kosten 00540 | Costs | number (float) | Must | — |
| satz 00550 | Type of concession levy | Enum AbgabeArt | Must | — |
KAS | — | — | Must | — |
SA | — | — | Must | — |
SAS | — | — | Must | — |
TA | — | — | Must | — |
TAS | — | — | Must | — |
TK | — | — | Must | — |
TKS | — | — | Must | — |
TS | — | — | Must | — |
TSS | — | — | Must | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| gasqualitaet 00560 | gasqualitaet for EDIFACT mapping | Enum Gasqualitaet | Must | — |
H_GAS | — | — | Must | — |
L_GAS | — | — | Must | — |
| messlokationsId * 00570 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| ablesekartenempfaenger | — | object | May | — |
| anrede 00580 | The form of address for the GePa, e.g. Mr. | string | X | — |
| gewerbekennzeichnung 00590 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | X | — |
| name1 00600 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00610 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00620 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00630 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 00640 | House number and supplement | string | X | — |
| landescode 00650 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00660 | City | string | X | — |
| ortsteil 00670 | District | string | X | — |
| postfach 00680 | PO box | string | X | — |
| postleitzahl 00690 | Postal code | string | X | — |
| strasse 00700 | Street | string | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00710 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| rollencodenummer 00720 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00730 | weiterverpflichtet | boolean | X | — |
| NETZNUTZUNGSVERTRAG [ ] * | — | object[] | Must | — |
| gemeinderabatt * 00740 | municipal discount for EDIFACT mapping. | integer | X | — |
| vertragsbeginn 00750 | Specifies when the contract begins. | string (date-time) | X | — |
| vertragsende 00760 | Specifies when the contract (is expected to) end or was ended. | string (date-time) | X | — |
| vertragskonditionen * | — | object | Must | — |
| haushaltskunde * 00770 | haushaltskunde | boolean | Must | — |
| naechstenetznutzungsabrechnung * 00780 | naechstenetznutzungsabrechnung | string | X | — |
| netznutzungsabrechnungIntervall * 00790 | netznutzungsabrechnungIntervall | integer | X | [504] |
| netznutzungsabrechnungsvariante * 00800 | Grid usage settlement variant | Enum Netznutzungsabrechnungsvariante | X | — |
ARBEITSPREIS_GRUNDPREIS | — | — | X | — |
ARBEITSPREIS_LEISTUNGSPREIS | — | — | X | — |
| netznutzungsvertrag * 00810 | Grid usage contract | Enum Netznutzungsvertrag | X | — |
KUNDEN_NB | — | — | X | — |
LIEFERANTEN_NB | — | — | X | — |
| netznutzungszahler * 00820 | Grid usage payer | Enum Netznutzungszahler | X | — |
KUNDE | — | — | X | — |
LIEFERANT | — | — | X | — |
| netznutzungsabrechnung * | — | object | Must | — |
| abrechnungsZeitraum * 00830 | abrechnungsZeitraum | string | X | — |
| ZAEHLER [ ] | — | object[] | May | — |
| messlokationsId 00840 | messlokationsId | string | X | — |
| messwerterfassung 00850 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| zaehlergroesse 00860 | Meter size | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlernummer 00870 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 00880 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 00890 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 00900 | The number printed on the device, which is assigned by the MSB. | string | X | — |
| geraeteeigenschaften | — | object | May | — |
| geraetemerkmal 00910 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlwerke [ ] | — | object[] | May | — |
| bezeichnung 00920 | Additional designation, e.g. Zählwerk_Wirkarbeit. | string | Must | — |
| nachkommastelle 00930 | nachkommastelle | integer | Must | — |
| obisKennzahl 00940 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| vorkommastelle 00950 | vorkommastelle | integer | Must | — |
| wertegranularitaet 00960 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer * 00970 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| antwortstatus * 00980 | Response status / STS+E01 | string | X | — |
| antwortstatusCodeliste * 00990 | Response status code list / STS+E01 | string | X | — |
| dokumentennummer * 01000 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| freitext 01010 | Free text / FTX+ACB | string | X | — |
| kategorie * 01020 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 01030 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 01040 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 01050 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 01060 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| transaktionsgrundergaenzungBefristeteAnmeldung 01070 | Supplement to the transaction reason for temporary registrations/deregistrations / UTILMD STS+7++E01+ZW4+### | string | X | — |
| vertragsbeginn 01080 | Contract start date / DTM+92 | string (date-time) | X | — |
| vertragsende 01090 | Contract end date / DTM+93 | string (date-time) | X | — |
| vorgangsnummer * 01100 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 01110 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 01120 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 01130 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 01140 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 44014 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 G1.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0100070 | Registrations | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 33200150 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00160 | Message recipient | — | X | — |
303900170 | MP-ID | — | X | — |
3055 900180 | GS1 | — | X | — |
3055 33200190 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400200 | Transaction | — | X | — |
740200210 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 9200220 | Contract start date | — | X | — |
238000230 | Date or time or time span, value | — | X | [UB2] |
2379 30300240 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.DTM | — | — | Must | [10] |
2005 9300250 | Contract end date | — | X | — |
238000260 | Date or time or time span, value | — | X | [UB2] |
2379 30300270 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.DTM | — | — | Must | [18] Should [28] ∧ [29] |
2005 15800280 | Start of balancing | — | X | — |
238000290 | Date or time or time span, value | — | X | [UB2] |
2379 30300300 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.DTM | — | — | Must | [28] ∧ [64] |
2005 15900310 | End of balancing | — | X | — |
238000320 | Date or time or time span, value | — | X | [UB2] |
2379 30300330 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.STS | — | — | Must | [2061] |
9015 700340 | Transaction reason | — | X | — |
9013 E0600350 | Replacement supply | — | X | [502] |
9013 Z0200360 | Contract termination of the supplier framework contract | — | X | — |
9013 Z3600370 | EoG due to move-in/move-out (relocation) | — | X | — |
9013 Z3700380 | EoG due to move-in to a new installation | — | X | — |
9013 Z3900390 | EoG due to temporary connection | — | X | — |
9013 ZC600400 | EoG due to balancing group closure | — | X | — |
9013 ZC700410 | EoG due to expiry of the allocation authorization | — | X | — |
9013 ZT600420 | EoG due to contract termination by LF | — | X | — |
9013 ZT700430 | EoG due to contract termination by the customer/LFN | — | X | — |
9013 ZZD00440 | Transitional supply | — | X | [505] |
| SG4.STS | — | — | Should | [37] |
9015 Z1700450 | Transaction reason supplement for temporary registration | — | X | — |
9013 E0100460 | Move-in/move-out (relocation) | — | X | — |
9013 E0300470 | Change | — | X | — |
| SG4.STS | — | — | Must | [249] |
9015 E0100480 | Status of the response | — | X | — |
901300490 | Code of the check step | — | X | — |
1131 G_001300500 | Gas code list no. G_0013 | — | X | — |
| SG4.FTX | — | — | May | — |
4451 ACB00510 | Additional information (for general notes) | — | X | — |
444000520 | Text for general information | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 17200530 | Reporting point | — | X | — |
322500540 | Identifier | — | X | [953] |
| SG6.RFF | — | — | Must | — |
1153 Z1300550 | Check identifier | — | X | — |
1154 4401400560 | GeLi Gas / Confirmation EoG registration | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00570 | Transaction reference number | — | X | — |
115400580 | Transaction number | — | X | — |
| SG6.RFF | — | — | Must | [636] |
1153 Z1800590 | Market location | — | X | — |
115400600 | ID of the market location | — | X | [950] |
| SG6.DTM | — | — | Must | — |
2005 Z2000610 | Billing interval of the LF | — | X | — |
238000620 | Date or time or time span, value | — | X | — |
2379 80200630 | Month | — | X | — |
| SG6.DTM | — | — | Must | — |
2005 Z2100640 | Grid usage settlement date | — | X | — |
238000650 | Date or time or time span, value | — | X | — |
2379 10600660 | MMDD | — | X | — |
2379 10400670 | MMWW-MMWW | — | X | — |
| SG6.DTM | — | — | Must | [230] |
2005 Z0900680 | Next grid usage settlement | — | X | — |
238000690 | Date or time or time span, value | — | X | — |
2379 60200700 | CCYY | — | X | — |
| SG6.DTM | — | — | Must | — |
2005 Z2200710 | Grid usage settlement or feed-in remuneration interval of the NB | — | X | [504] |
238000720 | Date or time or time span, value | — | X | — |
2379 80200730 | Month | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0100740 | Data of the market location | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 3100750 | Estimated annual quantity total | — | X | — |
606000760 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH00770 | Kilowatt hour | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Y0200780 | Customer value | — | X | — |
606000790 | Quantity specification | — | X | [902] ∧ [907] |
6411 KWH00800 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1900810 | Balancing group | — | X | — |
703700820 | Balancing group | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2100830 | Market area | — | X | — |
703700840 | Market area | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Y0100850 | Pressure level of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Y0100860 | High pressure | — | X | — |
7111 Y0200870 | Medium pressure | — | X | — |
7111 Y0300880 | Low pressure | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZC000890 | Forecast based on values | — | X | — |
7037 ZA600900 | Forecast based on profiles | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z1500910 | Household customer pursuant to EnWG | — | X | — |
7037 Z1800920 | Not a household customer under EnWG | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z1700930 | Case group assignment according to GABi Gas | — | X | — |
1131 GABi-RLMNEV00940 | Nomination replacement procedure - exit (note: this code may only be used for delivery months before 01.10.2016) | — | X | — |
1131 GABi-RLMmT00950 | RLM customer on daily regime - Exit | — | X | — |
1131 GABi-RLMoT00960 | RLM customer on hourly regime - Exit | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z8800970 | Grid usage | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z7400980 | Grid usage contract | — | X | — |
7110 Z0800990 | Direct contract between customer and NB | — | X | — |
7110 Z0901000 | Contract between supplier and NB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z7301010 | Payment of grid usage | — | X | — |
7110 Z1001020 | Customer | — | X | [216] |
7110 Z1101030 | Supplier | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZB101040 | Grid usage settlement variant | — | X | — |
7110 Z1401050 | Energy price/basic price | — | X | — |
7110 Z1501060 | Energy price/demand price | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0201070 | OBIS data of the market location | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 501080 | Product identification | — | X | — |
714001090 | OBIS code of the market location | — | X | [315] |
7143 SRW01100 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401110 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD901120 | Annually | — | X | — |
7111 ZE801130 | Semi-annual | — | X | — |
7111 ZE901140 | Quarterly | — | X | — |
7111 ZB701150 | Monthly | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0701160 | Concession levy data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1001170 | OBIS code | — | X | — |
115401180 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z0801190 | Concession levy | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 KAS01200 | for all special provisions under concession agreements that are not integrated into the structure of the KAV | — | X | — |
7111 SA01210 | Special contract customers < 1 kV under § 2 (7) and > 1 kV, price under § 2 (3) (for electricity 0.11 ct/kWh and for gas 0.03 ct/kWh) | — | X | — |
7111 SAS01220 | Indication that a different price applies for special contract customers | — | X | — |
7111 TA01230 | Tariff customers, for electricity § 2. (2) 1b HT or ET (high KA) and for gas § 2 (2) 2b | — | X | — |
7111 TAS01240 | Indication that a different price applies for tariff customers | — | X | — |
7111 TK01250 | for gas under KAV § 2 (2) 2a where used exclusively for cooking and hot water generation | — | X | — |
7111 TKS01260 | Indication when a different price is to be used pursuant to KAV § 2 (2) 2a | — | X | — |
711001270 | Concession levy in euro/kWh | — | Must | [912] ∧ [902] [128] |
711001280 | Fee category of the concession levy | — | Should | [219] |
| SG8.SEQ | — | — | Must | — |
1229 Z1201290 | Municipal discount | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z1601300 | Municipal discount | — | X | — |
606001310 | Quantity | — | X | [902] ∧ [930] ∧ [938] |
6411 P101320 | Percent | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1801330 | Data of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1901340 | Metering location | — | X | — |
115401350 | ID of the metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 ZB301360 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9101370 | MSB | — | X | — |
113101380 | MP-ID | — | X | — |
7110 Z1901390 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2001400 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF001410 | gMSB | — | X | — |
113101420 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Y0201430 | Gas quality | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Y0401440 | H-gas | — | X | — |
7111 Y0501450 | L-gas | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0301460 | Metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1901470 | Metering location | — | X | — |
115401480 | ID of a metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 E1301490 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 NMG01500 | new measuring equipment gas according to MsbG | — | X | — |
7111 DKZ01510 | Rotary piston gas meter | — | X | — |
7111 BGZ01520 | Diaphragm gas meter | — | X | — |
7111 TRZ01530 | Turbine gas meter | — | X | — |
7111 UGZ01540 | Ultrasonic gas meter | — | X | — |
7111 WGZ01550 | Vortex gas meter | — | X | — |
7111 EHZ01560 | electronic household meter | — | X | — |
7111 IVA01570 | Individual reconciliation (special equipment) | — | X | — |
| SG10.CAV | — | — | Must | — |
7110 G1001580 | Gas meter G10 | — | X | — |
7110 G10001590 | Gas meter G100 | — | X | — |
7110 G100001600 | Gas meter G1000 | — | X | — |
7110 G1000001610 | Gas meter G10000 | — | X | — |
7110 G1250001620 | Gas meter G12500 | — | X | — |
7110 G1601630 | Gas meter G16 | — | X | — |
7110 G16001640 | Gas meter G160 | — | X | — |
7110 G160001650 | Gas meter G1600 | — | X | — |
7110 G1600001660 | Gas meter G16000 | — | X | — |
7110 G2.501670 | Gas meter G2.5 | — | X | — |
7110 G2501680 | Gas meter G25 | — | X | — |
7110 G25001690 | Gas meter G250 | — | X | — |
7110 G250001700 | Gas meter G2500 | — | X | — |
7110 G35001710 | Gas meter G350 | — | X | — |
7110 G401720 | Gas meter G4 | — | X | — |
7110 G4001730 | Gas meter G40 | — | X | — |
7110 G40001740 | Gas meter G400 | — | X | — |
7110 G400001750 | Gas meter G4000 | — | X | — |
7110 G601760 | Gas meter G6 | — | X | — |
7110 G6501770 | Gas meter G65 | — | X | — |
7110 G65001780 | Gas meter G650 | — | X | — |
7110 G650001790 | Gas meter G6500 | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001800 | Device number | — | X | — |
711001810 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1201820 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR01830 | remotely readable meters | — | X | — |
7111 MMR01840 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z5001850 | Measurement data recording device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1901860 | Metering location | — | X | — |
115401870 | ID of a metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 E1301880 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001890 | Device number | — | X | — |
711001900 | Device number | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0901910 | Volume corrector data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG01920 | Device number of the meter | — | X | — |
115401930 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6401940 | Volume corrector | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001950 | Device number | — | X | — |
711001960 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 DMU01970 | Density volume converter | — | X | — |
7111 TMU01980 | Temperature volume converter | — | X | — |
7111 ZMU01990 | Volume conversion device | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2002000 | OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [655] |
1153 MG02010 | Device number of the meter | — | X | [442] |
1153 Z1102020 | Device number of the volume converter | — | X | — |
115402030 | Device number | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1902040 | Metering location | — | X | — |
115402050 | ID of a metering location | — | X | [951] |
| SG8.PIA | — | — | Must | — |
4347 502060 | Product identification | — | X | — |
714002070 | OBIS code of the metering device | — | X | [324] |
7143 SRW02080 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE402090 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD902100 | Annually | — | X | — |
7111 ZE802110 | Semi-annual | — | X | — |
7111 ZE902120 | Quarterly | — | X | — |
7111 ZB702130 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1102140 | Product | — | X | — |
7037 Z3302150 | Integer and decimal places of the register | — | X | — |
| SG10.CAV | — | — | Must | — |
711002160 | Digits before the decimal point | — | X | — |
711002170 | Digits after the decimal point | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6302180 | Local identifier for control purposes | — | X | — |
703602190 | Designation of the register on the device | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0502200 | Communication device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG02210 | Device number of the meter | — | X | — |
115402220 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2602230 | Communication device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3002240 | Device number | — | X | — |
711002250 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 GSM02260 | GSM/GPRS/UMTS comm. dev. | — | X | — |
7111 ETH02270 | Ethernet comm. dev. LAN/WLAN | — | X | — |
7111 PLC02280 | PLC comm. device | — | X | — |
7111 PST02290 | Landline comm. dev. TAE | — | X | — |
7111 DSL02300 | DSL comm. dev. | — | X | — |
7111 LTE02310 | LTE comm. dev. | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1302320 | Smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7502330 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3002340 | Device number | — | X | — |
711002350 | Device number | — | X | [952] |
| SG8.SEQ | — | — | Must | — |
1229 Z3502360 | Load profile data | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1202370 | Load profile | — | X | — |
7037 E0102380 | synthetic method | — | X | — |
7037 Z1002390 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711102400 | Code of the load profile | — | X | — |
3055 8902410 | Assigned by the trader (here grid operator) | — | X | — |
3055 29302420 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z9902430 | Measuring station of the daily parameter (currently only the temperature is a permitted daily parameter) | — | X | — |
7059 ZA002440 | Climate zone of the daily parameter (currently is daily parameter) | — | X | — |
703702450 | ID of climate zone / temperature measuring point | — | X | — |
113102460 | Service provider | — | X | [58] |
3055 8902470 | Assigned by the trader (here grid operator) | — | X | — |
3055 29302480 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0902490 | Customer of the LF | — | X | — |
303602500 | Name | — | X | — |
3045 Z0102510 | Structure of person names | — | X | — |
3045 Z0202520 | Structure of the company name | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0402530 | Correspondence address of the customer of the LF | — | X | — |
303602540 | Name | — | X | — |
3045 Z0102550 | Structure of person names | — | X | — |
3045 Z0202560 | Structure of the company name | — | X | — |
304202570 | Street and house number or PO box | — | X | — |
316402580 | City | — | X | — |
325102590 | Postal code | — | — | M [268] S [166] |
320702600 | Country name, code | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 DP02610 | Supply address | — | X | — |
312402620 | Additional information for identification | — | — | — |
304202630 | Street and house number or PO box | — | — | S [166] M [212] |
316402640 | City | — | X | — |
325102650 | Postal code | — | X | — |
320702660 | Country name, code | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0502670 | Name and address for the meter reading card | — | X | — |
303602680 | Name | — | X | — |
3045 Z0102690 | Structure of person names | — | X | — |
3045 Z0202700 | Structure of the company name | — | X | — |
304202710 | Street and house number or PO box | — | X | — |
316402720 | City | — | X | — |
325102730 | Postal code | — | — | M [268] S [166] |
320702740 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1902750 | Metering location | — | X | — |
115402760 | ID of a metering location | — | X | [951] |
| UNT | — | — | Must | — |
007402770 | Number of segments in a message | — | X | — |
006202780 | Message reference number | — | X | — |
Conditions of this table
The free text of the 37 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDG.
| Marker | Condition |
|---|---|
| [10] | If SG4 STS+Z17 (transaction reason for fixed-term registration) is present |
| [18] | If SG4 DTM+93 (end as of) is not present |
| [28] | If SG4 DTM+93 (end as of) is present |
| [29] | If balancing takes place |
| [37] | If the registration/change is limited in time |
| [58] | If in this CCI the DE3055 with the code 293 is present |
| [64] | If SG4 DTM+158 (start of balancing) is present |
| [128] | If SG10 CAV+TAS/TKS/SAS/KAS present |
| [166] | If present |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [216] | If CCI+++Z88 (grid usage) CAV+Z74:::Z08 (grid usage contract: direct contract between customer and NB) present |
| [219] | If present at the market location |
| [230] | Resulting date or end date of the cycle period from DTM+Z21 (date of the grid usage settlement) and DTM+Z09 (next grid usage settlement) must be >= DTM+92 (start on) |
| [249] | Within one SG4 IDE, all DE1131 of the SG4 STS+E01 must contain the identical value |
| [268] | If an "X" is listed for the code in DE3207 in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| [315] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 4, that are required at the market location must be stated; the minimum scope from chapter 4.6 must be observed. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.2 of the document "Code list of configurations" |
| [324] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes chapter 4. that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.2 of the document "Code list of configurations" |
| [442] | If the device number of the meter named in this RFF DE1154 is present in no SG8+SEQ+Z09 volume converter data in the RFF+MG (reference to the device number) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [502] | Note: Replacement supply exists only for - market locations at the low pressure level that are not household customers as defined by the EnWG and that are no longer subject to statutory substitute supply (three months) and - for market locations that are to be supplied at medium pressure. The basis for a replacement supply is the bilateral agreement |
| [504] | Note: Code Z22 is also used in the electricity division. The reference to the feed-in tariff interval is not relevant in the gas division |
| [505] | Note: Transitional supply exists only for market locations that fall under § 38a EnWG. The basis is a bilateral agreement |
| [636] | Note: Using a code in DE1153, this RFF classifies the DTM contained in the same segment group as content relevant to a market location or metering location |
| [655] | Note: If a meter is connected to a volume corrector, no OBIS code numbers are stated at the meter Here there are only OBIS code numbers from the volume corrector |
| [902] | Format: Possible value: ≥ 0 |
| [907] | Format: max. 4 decimal places |
| [912] | Format: max. 6 decimal places |
| [930] | Format: max. 2 decimal places |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [938] | Format: Possible value: <= 10 |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [953] | Format: market location ID or metering point identifier |
| [2061] | Segment or segment group must be specified exactly once per SG4 IDE (transaction) |
| [UB2] | ([931] ∧ [934] [490]) ⊻ ([931] ∧ [935] [491]) |
Example message
UNA:+.? '
UNB+UNOC:3+9800044300007:502+9870013800007:502+{{date}}:{{time}}+211739'
UNH+934676+UTILMD:D:11A:UN:G1.2'
BGM+E01+934676BGM'
DTM+137:202610011100?+00:303'
NAD+MS+9800044300007::332'
NAD+MR+9870013800007::332'
IDE+24+1023759574'
DTM+92:202406010400?+00:303'
DTM+93:202407010400?+00:303'
DTM+158:202406010400?+00:303'
DTM+159:202407010400?+00:303'
STS+7++E06'
STS+Z17++E03'
STS+E01++E15:G_0013'
FTX+ACB+++ABC123456'
LOC+172+50812938303'
LOC+172+DE7003318063400000000000090936184'
RFF+Z13:44014'
RFF+TN:ABC123456'
RFF+Z18:50812938303'
DTM+Z20:12:802'
DTM+Z21:0101:106'
DTM+Z09:2025:602'
DTM+Z22:12:802'
SEQ+Z01'
QTY+31:50000:KWH'
QTY+Y02:123.123:KWH'
CCI+Z19++11Y0-0000-0076-N'
CCI+Z21++11YR00000002596Z'
CCI+++Y01'
CAV+Y03'
CCI+++ZA6'
CCI+++Z15'
CCI+++Z88'
CAV+Z74:::Z09'
CAV+Z73:::Z11'
CAV+ZB1:::Z14'
SEQ+Z02'
PIA+5+7-0?:33.86.0:SRW'
CCI+++ZE4'
CAV+ZD9'
SEQ+Z07'
RFF+Z10:7-0?:33.86.0'
CCI+++Z08'
CAV+SA'
SEQ+Z12'
QTY+Z16:0:P1'
SEQ+Z18'
RFF+Z19:DE7003318063400000000000090936184'
CCI+++ZB3'
CAV+Z91:9800110000002::Z19'
CAV+ZF0:9800110000002'
CCI+++Y02'
CAV+Y04'
SEQ+Z03'
RFF+Z19:DE7003318063400000000000090936184'
CCI+++E13'
CAV+BGZ'
CAV+:::G4'
CAV+Z30:::ABC123456'
CCI+++E12'
CAV+MMR'
SEQ+Z50'
RFF+Z19:DE7003318063400000000000090936184'
CCI+++E13'
CAV+Z30:::XYZ123456'
SEQ+Z09'
RFF+MG:ABC123456'
CCI+++Z64'
CAV+Z30:::MMM123456'
CAV+DMU'
SEQ+Z20'
RFF+Z11:MMM123456'
RFF+Z19:DE7003318063400000000000090936184'
PIA+5+7-0?:3.0.0:SRW'
CCI+++ZE4'
CAV+ZD9'
CCI+11++Z33'
CAV+:::5:3'
SEQ+Z05'
RFF+MG:ABC123456'
CCI+++Z26'
CAV+Z30:::PPP123456'
CAV+LTE'
SEQ+Z35'
CCI+Z12++Z10'
CAV+N14::293'
CCI+Z99++1234:ZT1:293'
NAD+Z09+++Mustermann:::::Z01'
NAD+Z04+++Mustermann:::::Z01+Str.::1+Ort++12345+DE'
NAD+DP++Mustermann++Str.::1+Ort++12345+DE'
NAD+Z05+++Mustermann:::::Z01+Str.::1+Ort++12345+DE'
RFF+Z19:DE7003318063400000000000090936184'
UNT+93+934676'
UNZ+1+211739'[1 item
{6 fields
"data": {3 fields
"stammdaten": {6 fields
"MARKTLOKATION": [1 item
{8 fields
"lokationsadresse": {6 fields
"zusatzInformation": {1 field
"zaehlwerke": [1 item
{3 fields
"konzessionsabgabe": {1 field
"MESSLOKATION": [1 item
{7 fields
"ablesekartenempfaenger": {6 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {5 fields
"marktrollen": [2 items
{5 fields
{4 fields
"NETZNUTZUNGSVERTRAG": [1 item
{10 fields
"vertragskonditionen": {7 fields
"netznutzungsabrechnung": {1 field
"ENERGIELIEFERVERTRAG": [1 item
{9 fields
"vertragspartner2": [1 item
{5 fields
"geschaeftspartnerrolle": [1 item
"vertragskonditionen": {1 field
"korrespondenzpartner": {5 fields
"partneradresse": {5 fields
"ZAEHLER": [1 item
{10 fields
"zaehlwerke": [1 item
{4 fields
"geraete": [3 items
{2 fields
"geraeteeigenschaften": {1 field
{2 fields
"geraeteeigenschaften": {2 fields
{2 fields
"geraeteeigenschaften": {2 fields
"BILANZIERUNG": [1 item
{10 fields
"lastprofile": [1 item
{6 fields
"tagesparameter": {3 fields
"bilanzkreise": [1 item
{1 field
"jahresverbrauchsprognose": {2 fields
"kundenwert": {1 field
"transaktionsdaten": {18 fields
"absender": {4 fields
"empfaenger": {4 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF and NB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Start of replacement supply / default supply | GeLi Gas 2.0 | Gas | Step 2 |
| NB | NB | Start of replacement supply / default supply | GeLi Gas 2.0 | Gas | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Confirmation of EoG registration |
| AHB | UTILMD AHB gas |
| Decision tree | E_3008 |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GeLi Gas 2.0 | Start of the replacement supply / default supply | LF (corresponds to E/G) → NB | Response to registration for E/G |
| GeLi Gas | Ch. C 2.3 No. 4a | E/G → NB | Notification by the E/G whether and, if applicable, for which time period the market location is to be assigned to substitute supply or basic supply. |
Transaction and responses
Role of this check identifier: response — confirmation. Basis: the transaction data carry antwortstatus and antwortstatusCodeliste; the title or the action of the Prüfi table begins with “response”; the title names a polarity (confirmation).
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 44013 | Registration EoG | UTILMD_GAS | from the step sequence |
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfragereferenznummer | SG4.IDE+24.SG6.RFF+TN | vorgangsnummer |
For RFF+TN, the field description of the time slice names the »reference transaction number (from request message)« — the target is the vorgangsnummer in segment SG4.IDE+24 of the request. Measured: 44013 carries vorgangsnummer in SG4.IDE+24.
Response codes
Decision trees: G_0013 · E_3008.
The Prüfi table names one further tree across all rows of this check identifier. They tie it to a process, not to a row of its handbook — their codes are therefore only on the respective tree page. For G_0013 there is no decision tree in version 202610; its response codes are therefore not given here.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDG has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 375 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type utilmdGas. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.