Check identifier 44145 — Response to request
Check identifier 44145 · EDIFACT message type UTILMD_GAS · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 44145 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| messlokationsId * 00010 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| NETZNUTZUNGSVERTRAG [ ] | — | object[] | May | — |
| vertragsbeginn 00020 | Specifies when the contract begins. | string (date-time) | X | — |
| ZAEHLER [ ] | — | object[] | May | — |
| messlokationsId 00030 | messlokationsId | string | X | — |
| messwerterfassung 00040 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| zaehlergroesse 00050 | Meter size | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlernummer 00060 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 00070 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 00080 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 00090 | The number printed on the device, which is assigned by the MSB. | string | X | — |
| geraeteeigenschaften | — | object | May | — |
| geraetemerkmal 00100 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlwerke [ ] | — | object[] | May | — |
| bezeichnung 00110 | Additional designation, e.g. Zählwerk_Wirkarbeit. | string | Must | — |
| nachkommastelle 00120 | nachkommastelle | integer | Must | — |
| obisKennzahl 00130 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| vorkommastelle 00140 | vorkommastelle | integer | Must | — |
| wertegranularitaet 00150 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer * 00160 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| antwortstatus * 00170 | Response status / STS+E01 | string | X | — |
| antwortstatusCodeliste * 00180 | Response status code list / STS+E01 | string | X | — |
| dokumentennummer * 00190 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| gueltigAb * 00200 | Effective date/time / DTM+7 | string (date-time) | X | — |
| kategorie * 00210 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 00220 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00230 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00240 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 00250 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vertragsbeginn 00260 | Contract start date / DTM+92 | string (date-time) | X | — |
| vorgangsnummer * 00270 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00280 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00290 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00300 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00310 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 44145 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 G1.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0300070 | Change notifications | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 33200150 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00160 | Message recipient | — | X | — |
303900170 | MP-ID | — | X | — |
3055 900180 | GS1 | — | X | — |
3055 33200190 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400200 | Transaction | — | X | — |
740200210 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 9200220 | Contract start date | — | X | — |
238000230 | Date or time or time span, value | — | X | [UB2] ∧ [528] |
2379 30300240 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 15700250 | Validity, start date | — | X | — |
238000260 | Date or time or time span, value | — | X | [UB2] ∧ [528] |
2379 30300270 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.STS | — | — | Must | [2061] |
9015 700280 | Transaction reason | — | X | — |
9013 ZF500290 | Request to MSB with dependencies | — | X | — |
| SG4.STS | — | — | Must | [249] |
9015 E0100300 | Status of the response | — | X | — |
901300310 | Code of the check step | — | X | — |
1131 G_004700320 | Gas code list no. G_0047 | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 17200330 | Reporting point | — | X | — |
322500340 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300350 | Check identifier | — | X | — |
1154 4414500360 | SDÄ Gas / Response to request to MSB with dependencies NB to AF | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00370 | Transaction reference number | — | X | — |
115400380 | Transaction number | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0300390 | Metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1900400 | Metering location | — | X | — |
115400410 | ID of a metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 E1300420 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 NMG00430 | new measuring equipment gas according to MsbG | — | X | — |
7111 DKZ00440 | Rotary piston gas meter | — | X | — |
7111 BGZ00450 | Diaphragm gas meter | — | X | — |
7111 TRZ00460 | Turbine gas meter | — | X | — |
7111 UGZ00470 | Ultrasonic gas meter | — | X | — |
7111 WGZ00480 | Vortex gas meter | — | X | — |
7111 EHZ00490 | electronic household meter | — | X | — |
7111 IVA00500 | Individual reconciliation (special equipment) | — | X | — |
| SG10.CAV | — | — | Must | — |
7110 G1000510 | Gas meter G10 | — | X | — |
7110 G10000520 | Gas meter G100 | — | X | — |
7110 G100000530 | Gas meter G1000 | — | X | — |
7110 G1000000540 | Gas meter G10000 | — | X | — |
7110 G1250000550 | Gas meter G12500 | — | X | — |
7110 G1600560 | Gas meter G16 | — | X | — |
7110 G16000570 | Gas meter G160 | — | X | — |
7110 G160000580 | Gas meter G1600 | — | X | — |
7110 G1600000590 | Gas meter G16000 | — | X | — |
7110 G2.500600 | Gas meter G2.5 | — | X | — |
7110 G2500610 | Gas meter G25 | — | X | — |
7110 G25000620 | Gas meter G250 | — | X | — |
7110 G250000630 | Gas meter G2500 | — | X | — |
7110 G35000640 | Gas meter G350 | — | X | — |
7110 G400650 | Gas meter G4 | — | X | — |
7110 G4000660 | Gas meter G40 | — | X | — |
7110 G40000670 | Gas meter G400 | — | X | — |
7110 G400000680 | Gas meter G4000 | — | X | — |
7110 G600690 | Gas meter G6 | — | X | — |
7110 G6500700 | Gas meter G65 | — | X | — |
7110 G65000710 | Gas meter G650 | — | X | — |
7110 G650000720 | Gas meter G6500 | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3000730 | Device number | — | X | — |
711000740 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1200750 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR00760 | remotely readable meters | — | X | — |
7111 MMR00770 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z5000780 | Measurement data recording device data | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1300790 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3000800 | Device number | — | X | — |
711000810 | Device number | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0900820 | Volume corrector data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG00830 | Device number of the meter | — | X | — |
115400840 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6400850 | Volume corrector | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3000860 | Device number | — | X | — |
711000870 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 DMU00880 | Density volume converter | — | X | — |
7111 TMU00890 | Temperature volume converter | — | X | — |
7111 ZMU00900 | Volume conversion device | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2000910 | OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [655] |
1153 MG00920 | Device number of the meter | — | X | [442] |
1153 Z1100930 | Device number of the volume converter | — | X | — |
115400940 | Device number | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1900950 | Metering location | — | X | — |
115400960 | ID of a metering location | — | X | [951] |
| SG8.PIA | — | — | Must | — |
4347 500970 | Product identification | — | X | — |
714000980 | OBIS code of the metering device | — | X | [324] |
7143 SRW00990 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401000 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD901010 | Annually | — | X | — |
7111 ZE801020 | Semi-annual | — | X | — |
7111 ZE901030 | Quarterly | — | X | — |
7111 ZB701040 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1101050 | Product | — | X | — |
7037 Z3301060 | Integer and decimal places of the register | — | X | — |
| SG10.CAV | — | — | Must | — |
711001070 | Digits before the decimal point | — | X | — |
711001080 | Digits after the decimal point | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6301090 | Local identifier for control purposes | — | X | — |
703601100 | Designation of the register on the device | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0501110 | Communication device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG01120 | Device number of the meter | — | X | — |
115401130 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2601140 | Communication device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001150 | Device number | — | X | — |
711001160 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 GSM01170 | GSM/GPRS/UMTS comm. dev. | — | X | — |
7111 ETH01180 | Ethernet comm. dev. LAN/WLAN | — | X | — |
7111 PLC01190 | PLC comm. device | — | X | — |
7111 PST01200 | Landline comm. dev. TAE | — | X | — |
7111 DSL01210 | DSL comm. dev. | — | X | — |
7111 LTE01220 | LTE comm. dev. | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1301230 | Smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7501240 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001250 | Device number | — | X | — |
711001260 | Device number | — | X | [952] |
| UNT | — | — | Must | — |
007401270 | Number of segments in a message | — | X | — |
006201280 | Message reference number | — | X | — |
Conditions of this table
The free text of the 11 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDG.
| Marker | Condition |
|---|---|
| [249] | Within one SG4 IDE, all DE1131 of the SG4 STS+E01 must contain the identical value |
| [324] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes chapter 4. that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.2 of the document "Code list of configurations" |
| [442] | If the device number of the meter named in this RFF DE1154 is present in no SG8+SEQ+Z09 volume converter data in the RFF+MG (reference to the device number) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [528] | Note: The date/dates from the request must be used |
| [655] | Note: If a meter is connected to a volume corrector, no OBIS code numbers are stated at the meter Here there are only OBIS code numbers from the volume corrector |
| [931] | Format: ZZZ = +00 |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [2061] | Segment or segment group must be specified exactly once per SG4 IDE (transaction) |
| [UB2] | ([931] ∧ [934] [490]) ⊻ ([931] ∧ [935] [491]) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | BER | Request for a master data change from the LF to MSB (responsible) | GeLi Gas 2.0 | Gas | Step 4 |
| LF | WLF | Request for a master data change from the LF to MSB (responsible) | GeLi Gas 2.0 | Gas | Step 4 |
| NB | NB | Request for a master data change from the LF to MSB (responsible) | GeLi Gas 2.0 | Gas | Step 4 |
| MSB | BER | Request for a master data change from the LF to MSB (responsible) | GeLi Gas 2.0 | Gas | Step 4 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response to request |
| AHB | UTILMD AHB gas |
| Response to check identifier | 44143 |
| Decision tree | E_3017 |
| Transmission channel | AS4 |
This check identifier is used in 3 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GeLi Gas 2.0 | Request for master data change from the LF to the MSB (responsible) | NB (distributor) → LF (authorised party) | Response to request to MSB |
| GeLi Gas | Ch. D 2.3.5 No. 4 | NB [Distributor] → LF | Response to request to MSB |
| GeLi Gas | Ch. D 2.3.2 No. 2 | NB [Distributor] → gMSB | Response to request to NB from MSB |
Transaction and responses
Role of this check identifier: response. Basis: the transaction data carry antwortstatus and antwortstatusCodeliste; the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 44143 | Request to MSB with dependencies | UTILMD_GAS | explicit, not adjacent |
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfragereferenznummer | SG4.IDE+24.SG6.RFF+TN | vorgangsnummer |
For RFF+TN, the time slice field description gives »reference transaction number (from request message)« — the target is the vorgangsnummer in segment SG4.IDE+24 of the request. Measured: 44143 lists vorgangsnummer in SG4.IDE+24.
Response codes
Decision trees: G_0047 · E_3017.
The Prüfi table names one further tree across all rows of this check identifier. They tie it to a process, not to a row of its handbook — their codes are therefore only on the respective tree page. For G_0047 there is no decision tree in version 202610; its response codes are therefore not given here.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDG has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 175 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
No test case exists for this check identifier in the test data of the format version. There is therefore no example message here — not even a reconstructed one: on a page that promises evidence, an invented message would be worse than none.