Check identifier 44147 — Request to MSB with dependencies
Check identifier 44147 · EDIFACT message type UTILMD_GAS · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 44147 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| messlokationsId * 00010 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| NETZNUTZUNGSVERTRAG [ ] | — | object[] | May | — |
| vertragsbeginn 00020 | Specifies when the contract begins. | string (date-time) | X | — |
| ZAEHLER [ ] | — | object[] | May | — |
| messlokationsId 00030 | messlokationsId | string | X | — |
| messwerterfassung 00040 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| zaehlergroesse 00050 | Meter size | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlernummer 00060 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 00070 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 00080 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 00090 | The number printed on the device, which is assigned by the MSB. | string | X | — |
| geraeteeigenschaften | — | object | May | — |
| geraetemerkmal 00100 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlwerke [ ] | — | object[] | May | — |
| bezeichnung 00110 | Additional designation, e.g. Zählwerk_Wirkarbeit. | string | Must | — |
| nachkommastelle 00120 | nachkommastelle | integer | Must | — |
| obisKennzahl 00130 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| vorkommastelle 00140 | vorkommastelle | integer | Must | — |
| wertegranularitaet 00150 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| dokumentennummer * 00160 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| gueltigAb * 00170 | Effective date/time / DTM+7 | string (date-time) | X | — |
| kategorie * 00180 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 00190 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00200 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00210 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 00220 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vertragsbeginn 00230 | Contract start date / DTM+92 | string (date-time) | X | — |
| vorgangsnummer * 00240 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00250 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00260 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00270 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00280 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 44147 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 G1.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0300070 | Change notifications | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 33200150 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00160 | Message recipient | — | X | — |
303900170 | MP-ID | — | X | — |
3055 900180 | GS1 | — | X | — |
3055 33200190 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400200 | Transaction | — | X | — |
740200210 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 9200220 | Contract start date | — | X | — |
238000230 | Date or time or time span, value | — | X | [UB2] ∧ [528] |
2379 30300240 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 15700250 | Validity, start date | — | X | — |
238000260 | Date or time or time span, value | — | X | [UB2] ∧ [528] |
2379 30300270 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.STS | — | — | Must | [2061] |
9015 700280 | Transaction reason | — | X | — |
9013 ZF500290 | Request to MSB with dependencies | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 17200300 | Reporting point | — | X | — |
322500310 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300320 | Check identifier | — | X | — |
1154 4414700330 | SDÄ Gas / Request to MSB with dependencies NB [Distributor] to MSB | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0300340 | Metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1900350 | Metering location | — | X | — |
115400360 | ID of a metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 E1300370 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 NMG00380 | new measuring equipment gas according to MsbG | — | X | — |
7111 DKZ00390 | Rotary piston gas meter | — | X | — |
7111 BGZ00400 | Diaphragm gas meter | — | X | — |
7111 TRZ00410 | Turbine gas meter | — | X | — |
7111 UGZ00420 | Ultrasonic gas meter | — | X | — |
7111 WGZ00430 | Vortex gas meter | — | X | — |
7111 EHZ00440 | electronic household meter | — | X | — |
7111 IVA00450 | Individual reconciliation (special equipment) | — | X | — |
| SG10.CAV | — | — | Must | — |
7110 G1000460 | Gas meter G10 | — | X | — |
7110 G10000470 | Gas meter G100 | — | X | — |
7110 G100000480 | Gas meter G1000 | — | X | — |
7110 G1000000490 | Gas meter G10000 | — | X | — |
7110 G1250000500 | Gas meter G12500 | — | X | — |
7110 G1600510 | Gas meter G16 | — | X | — |
7110 G16000520 | Gas meter G160 | — | X | — |
7110 G160000530 | Gas meter G1600 | — | X | — |
7110 G1600000540 | Gas meter G16000 | — | X | — |
7110 G2.500550 | Gas meter G2.5 | — | X | — |
7110 G2500560 | Gas meter G25 | — | X | — |
7110 G25000570 | Gas meter G250 | — | X | — |
7110 G250000580 | Gas meter G2500 | — | X | — |
7110 G35000590 | Gas meter G350 | — | X | — |
7110 G400600 | Gas meter G4 | — | X | — |
7110 G4000610 | Gas meter G40 | — | X | — |
7110 G40000620 | Gas meter G400 | — | X | — |
7110 G400000630 | Gas meter G4000 | — | X | — |
7110 G600640 | Gas meter G6 | — | X | — |
7110 G6500650 | Gas meter G65 | — | X | — |
7110 G65000660 | Gas meter G650 | — | X | — |
7110 G650000670 | Gas meter G6500 | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3000680 | Device number | — | X | — |
711000690 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1200700 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR00710 | remotely readable meters | — | X | — |
7111 MMR00720 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z5000730 | Measurement data recording device data | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1300740 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3000750 | Device number | — | X | — |
711000760 | Device number | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0900770 | Volume corrector data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG00780 | Device number of the meter | — | X | — |
115400790 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6400800 | Volume corrector | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3000810 | Device number | — | X | — |
711000820 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 DMU00830 | Density volume converter | — | X | — |
7111 TMU00840 | Temperature volume converter | — | X | — |
7111 ZMU00850 | Volume conversion device | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2000860 | OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [655] |
1153 MG00870 | Device number of the meter | — | X | [442] |
1153 Z1100880 | Device number of the volume converter | — | X | — |
115400890 | Device number | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1900900 | Metering location | — | X | — |
115400910 | ID of a metering location | — | X | [951] |
| SG8.PIA | — | — | Must | — |
4347 500920 | Product identification | — | X | — |
714000930 | OBIS code of the metering device | — | X | [324] |
7143 SRW00940 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE400950 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD900960 | Annually | — | X | — |
7111 ZE800970 | Semi-annual | — | X | — |
7111 ZE900980 | Quarterly | — | X | — |
7111 ZB700990 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1101000 | Product | — | X | — |
7037 Z3301010 | Integer and decimal places of the register | — | X | — |
| SG10.CAV | — | — | Must | — |
711001020 | Digits before the decimal point | — | X | — |
711001030 | Digits after the decimal point | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6301040 | Local identifier for control purposes | — | X | — |
703601050 | Designation of the register on the device | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0501060 | Communication device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG01070 | Device number of the meter | — | X | — |
115401080 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2601090 | Communication device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001100 | Device number | — | X | — |
711001110 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 GSM01120 | GSM/GPRS/UMTS comm. dev. | — | X | — |
7111 ETH01130 | Ethernet comm. dev. LAN/WLAN | — | X | — |
7111 PLC01140 | PLC comm. device | — | X | — |
7111 PST01150 | Landline comm. dev. TAE | — | X | — |
7111 DSL01160 | DSL comm. dev. | — | X | — |
7111 LTE01170 | LTE comm. dev. | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1301180 | Smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7501190 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001200 | Device number | — | X | — |
711001210 | Device number | — | X | [952] |
| UNT | — | — | Must | — |
007401220 | Number of segments in a message | — | X | — |
006201230 | Message reference number | — | X | — |
Conditions of this table
The free text of the 10 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDG.
| Marker | Condition |
|---|---|
| [324] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes chapter 4. that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.2 of the document "Code list of configurations" |
| [442] | If the device number of the meter named in this RFF DE1154 is present in no SG8+SEQ+Z09 volume converter data in the RFF+MG (reference to the device number) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [528] | Note: The date/dates from the request must be used |
| [655] | Note: If a meter is connected to a volume corrector, no OBIS code numbers are stated at the meter Here there are only OBIS code numbers from the volume corrector |
| [931] | Format: ZZZ = +00 |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [2061] | Segment or segment group must be specified exactly once per SG4 IDE (transaction) |
| [UB2] | ([931] ∧ [934] [490]) ⊻ ([931] ∧ [935] [491]) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | BER | Request for a master data change from the LF to MSB (responsible) | GeLi Gas 2.0 | Gas | Step 2 |
| LF | WLF | Request for a master data change from the LF to MSB (responsible) | GeLi Gas 2.0 | Gas | Step 2 |
| NB | NB | Request for a master data change from the LF to MSB (responsible) | GeLi Gas 2.0 | Gas | Step 2 |
| MSB | BER | Request for a master data change from the LF to MSB (responsible) | GeLi Gas 2.0 | Gas | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Request to MSB with dependencies |
| AHB | UTILMD AHB gas |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GeLi Gas 2.0 | Request for master data change from the LF to the MSB (responsible) | NB (distributor) → MSB (authorised party) | Request to MSB (forwarding) |
| GeLi Gas | Ch. D 2.3.5 No. 2 | NB [distributor] → MSB | Request to MSB (forwarding to MSB) |
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.
Which messages respond to this
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Response | 44149 | Response to request | UTILMD_GAS | explicit |
This column is the inverse of the assignment on the response pages — not the next step of a list. The process source says of its own steps that they are »possible messages, not a sequence«.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDG has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 168 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
No test case exists for this check identifier in the test data of the format version. There is therefore no example message here — not even a reconstructed one: on a page that promises evidence, an invented message would be worse than none.