Check identifier 44043 — Confirmation of registration MSB
Check identifier 44043 · EDIFACT message type UTILMD_GAS · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 44043 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| betriebszustand * 00010 | Operating state | Enum Betriebszustand | X | — |
GESPERRT_NICHT_ENTSPERREN | — | — | X | — |
GESPERRT | — | — | X | — |
REGELBETRIEB | — | — | X | — |
AUSSERHALB_REGELBETRIEB | — | — | X | — |
| gasqualitaet * 00020 | gasqualitaet for EDIFACT mapping | Enum Gasqualitaet | Must | — |
H_GAS | — | — | Must | — |
L_GAS | — | — | Must | — |
| messlokationsId * 00030 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| ablesekartenempfaenger * | — | object | Must | — |
| anrede 00040 | The form of address for the GePa, e.g. Mr. | string | X | — |
| gewerbekennzeichnung 00050 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | X | — |
| name1 * 00060 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00070 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00080 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00090 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 00100 | House number and supplement | string | X | — |
| landescode 00110 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00120 | City | string | X | — |
| ortsteil 00130 | District | string | X | — |
| postfach 00140 | PO box | string | X | — |
| postleitzahl 00150 | Postal code | string | X | — |
| strasse 00160 | Street | string | X | — |
| marktrollen [ ] * | — | object[] | Must | — |
| marktrolle 00170 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| rollencodenummer * 00180 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet * 00190 | weiterverpflichtet | boolean | X | — |
| messadresse | — | object | May | — |
| hausnummer 00200 | House number and supplement | string | X | — |
| landescode 00210 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00220 | City | string | X | — |
| ortsteil 00230 | District | string | X | — |
| postfach 00240 | PO box | string | X | — |
| postleitzahl 00250 | Postal code | string | X | — |
| strasse 00260 | Street | string | X | — |
| zusatzInformation | — | object | May | — |
| zusatz1 00270 | Address supplement 1 | string | X | — |
| zusatz2 00280 | Address supplement 2 | string | X | — |
| zusatz3 00290 | Address supplement 3 | string | X | — |
| zusatz4 00300 | Address supplement 4 | string | X | — |
| zusatz5 00310 | Address supplement 5 | string | X | — |
| zaehlwerke [ ] * | — | object[] | Must | — |
| messprodukt * 00320 | messprodukt | string | X | — |
| MESSSTELLENBETRIEBSVERTRAG [ ] * | — | object[] | Must | — |
| lokationsId * 00330 | lokationsId | string | X | — |
| lokationsTyp * 00340 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | X | — |
MALO | — | — | X | — |
MELO | — | — | X | — |
NELO | — | — | X | — |
TECHNISCHE_RESSOURCE | — | — | X | — |
STEUERBARE_RESSOURCE | — | — | X | — |
TRANCHE | — | — | X | — |
MABIS_ZAEHLPUNKT | — | — | X | — |
| korrespondenzpartner * | — | object | Must | — |
| anrede 00350 | The form of address for the GePa, e.g. Mr. | string | X | — |
| gewerbekennzeichnung 00360 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | X | — |
| name1 * 00370 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00380 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00390 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00400 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 00410 | House number and supplement | string | X | — |
| landescode 00420 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00430 | City | string | X | — |
| ortsteil 00440 | District | string | X | — |
| postfach 00450 | PO box | string | X | — |
| postleitzahl 00460 | Postal code | string | X | — |
| strasse 00470 | Street | string | X | — |
| vertragskonditionen * | — | object | Must | — |
| geplanteTurnusablesung * | — | object | Must | — |
| ableseZeitraum * 00480 | ableseZeitraum | string | X | — |
| vertragspartner2 [ ] * | — | object[] | Must | — |
| anrede 00490 | The form of address for the GePa, e.g. Mr. | string | X | — |
| gewerbekennzeichnung 00500 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | X | — |
| name1 * 00510 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00520 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00530 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00540 | name4 | string | X | — |
| ZAEHLER [ ] | — | object[] | May | — |
| befestigungsart 00550 | Mounting type | Enum Befestigungsart | Must | — |
STECKTECHNIK | — | — | Must | — |
DREIPUNKT | — | — | Must | — |
HUTSCHIENE | — | — | Must | — |
EINSTUTZEN | — | — | Must | — |
ZWEISTUTZEN | — | — | Must | — |
| messlokationsId 00560 | messlokationsId | string | X | — |
| messwerterfassung 00570 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| volumenerfassung 00580 | Volume measurement | Enum Volumenerfassung | X | — |
HOCHFREQUENZSONDE | — | — | X | — |
KENNLINIENKORREKTUR | — | — | X | — |
SCHLEICHMENGENUNTERDRUECKUNG | — | — | X | — |
| zaehlergroesse 00590 | Meter size | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlernummer 00600 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 00610 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 00620 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 00630 | The number printed on the device, which is assigned by the MSB. | string | X | — |
| geraeteeigenschaften | — | object | May | — |
| geraetemerkmal 00640 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| volumenerfassung 00650 | Volume measurement | Enum Volumenerfassung | X | — |
HOCHFREQUENZSONDE | — | — | X | — |
KENNLINIENKORREKTUR | — | — | X | — |
SCHLEICHMENGENUNTERDRUECKUNG | — | — | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| nachkommastelle 00660 | nachkommastelle | integer | Must | — |
| obisKennzahl 00670 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| vorkommastelle 00680 | vorkommastelle | integer | Must | — |
| wertegranularitaet 00690 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer * 00700 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| antwortstatus * 00710 | Response status / STS+E01 | string | X | — |
| antwortstatusCodeliste * 00720 | Response status code list / STS+E01 | string | X | — |
| datumleistungsbeginn * 00730 | Date of the planned start of service / DTM+76 | string (date-time) | X | — |
| dokumentennummer * 00740 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| kategorie * 00750 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 00760 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00770 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00780 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 00790 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vorgangsnummer * 00800 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00810 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00820 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00830 | Email address | string | Must | — |
| nachname 00840 | Surname (family name) of the contact person | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00850 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00860 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00870 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00880 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 44043 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 G1.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0100070 | Registrations | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/ message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/ message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 33200150 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00160 | Information contact | — | X | — |
341200170 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800180 | Number / address | — | X | — |
3155 EM00190 | Electronic mail | — | X | [1P0..1] |
3155 FX00200 | Fax number | — | X | [1P0..1] |
3155 TE00210 | Telephone | — | X | [1P0..1] |
3155 AJ00220 | further telephone | — | X | [1P0..1] |
3155 AL00230 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00240 | Message recipient | — | X | — |
303900250 | MP-ID | — | X | — |
3055 900260 | GS1 | — | X | — |
3055 33200270 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400280 | Transaction | — | X | — |
740200290 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 7600300 | Delivery date/time, scheduled | — | X | — |
238000310 | Date or time or time span, value | — | X | [UB2] |
2379 30300320 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.STS | — | — | Must | [2061] |
9015 700330 | Transaction reason | — | X | — |
9013 E0100340 | Move-in/move-out (relocation) | — | X | — |
9013 E0200350 | Move-in to creation | — | X | — |
9013 E0300360 | Change | — | X | — |
| SG4.STS | — | — | Must | [249] |
9015 E0100370 | Status of the response | — | X | — |
901300380 | Code of the check step | — | X | — |
1131 G_005400390 | Gas code list no. G_0054 | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 17200400 | Reporting point | — | X | — |
322500410 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300420 | Check identifier | — | X | — |
1154 4404300430 | WiM gas / confirmation of registration MSB | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00440 | Transaction reference number | — | X | — |
115400450 | Transaction number | — | X | — |
| SG6.RFF | — | — | Must | [636] |
1153 Z1900460 | Metering location | — | X | — |
115400470 | ID of the metering location | — | X | [951] |
| SG6.DTM | — | — | Must | — |
2005 75200480 | Periodic meter reading | — | X | — |
238000490 | Date or time or time span, value | — | X | — |
2379 10400500 | MMWW-MMWW | — | X | — |
2379 10600510 | MMDD | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1800520 | Data of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1900530 | Metering location | — | X | — |
115400540 | ID of the metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 ZB300550 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9100560 | MSB | — | X | — |
113100570 | MP-ID | — | X | [621] |
7110 Z1900580 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2000590 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF000600 | gMSB | — | X | — |
113100610 | MP-ID | — | X | — |
| SG10.CAV | — | — | Must | [78] |
7111 ZB400620 | MSBA | — | X | — |
113100630 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Y0200640 | Gas quality | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Y0400650 | H-gas | — | X | — |
7111 Y0500660 | L-gas | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3200670 | Operating state of the metering location | — | X | — |
7037 ZC100680 | Metering location blocked and may not be unblocked | — | X | — |
7037 ZC200690 | Metering location blocked and may be unblocked | — | X | — |
7037 ZC300700 | Metering location in regular operation | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1900710 | Required product of the metering location | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 500720 | Product identification | — | X | — |
714000730 | Metering product code | — | X | [427] |
7143 Z1100740 | Product | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0300750 | Metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1900760 | Metering location | — | X | — |
115400770 | ID of a metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 E1300780 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 NMG00790 | new measuring equipment gas according to MsbG | — | X | — |
7111 DKZ00800 | Rotary piston gas meter | — | X | — |
7111 BGZ00810 | Diaphragm gas meter | — | X | — |
7111 TRZ00820 | Turbine gas meter | — | X | — |
7111 UGZ00830 | Ultrasonic gas meter | — | X | — |
7111 WGZ00840 | Vortex gas meter | — | X | — |
7111 EHZ00850 | electronic household meter | — | X | — |
7111 IVA00860 | Individual reconciliation (special equipment) | — | X | — |
| SG10.CAV | — | — | Must | — |
7110 G1000870 | Gas meter G10 | — | X | — |
7110 G10000880 | Gas meter G100 | — | X | — |
7110 G100000890 | Gas meter G1000 | — | X | — |
7110 G1000000900 | Gas meter G10000 | — | X | — |
7110 G1250000910 | Gas meter G12500 | — | X | — |
7110 G1600920 | Gas meter G16 | — | X | — |
7110 G16000930 | Gas meter G160 | — | X | — |
7110 G160000940 | Gas meter G1600 | — | X | — |
7110 G1600000950 | Gas meter G16000 | — | X | — |
7110 G2.500960 | Gas meter G2.5 | — | X | — |
7110 G2500970 | Gas meter G25 | — | X | — |
7110 G25000980 | Gas meter G250 | — | X | — |
7110 G250000990 | Gas meter G2500 | — | X | — |
7110 G35001000 | Gas meter G350 | — | X | — |
7110 G401010 | Gas meter G4 | — | X | — |
7110 G4001020 | Gas meter G40 | — | X | — |
7110 G40001030 | Gas meter G400 | — | X | — |
7110 G400001040 | Gas meter G4000 | — | X | — |
7110 G601050 | Gas meter G6 | — | X | — |
7110 G6501060 | Gas meter G65 | — | X | — |
7110 G65001070 | Gas meter G650 | — | X | — |
7110 G650001080 | Gas meter G6500 | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001090 | Device number | — | X | — |
711001100 | Device number | — | X | — |
| SG10.CAV | — | — | Should | [166] |
7111 ZC001110 | Type of volume measurement | — | X | — |
7110 Z1601120 | High-frequency probe | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2801130 | Mounting type metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3101140 | Single-connection meter | — | X | — |
7111 Z3201150 | Two-connection meter | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1201160 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR01170 | remotely readable meters | — | X | — |
7111 MMR01180 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z5001190 | Measurement data recording device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1901200 | Metering location | — | X | — |
115401210 | ID of a metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 E1301220 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001230 | Device number | — | X | — |
711001240 | Device number | — | X | — |
| SG10.CAV | — | — | Should | [166] |
7111 ZC001250 | Type of volume measurement | — | X | — |
7110 Z1601260 | High-frequency probe | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0901270 | Volume corrector data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG01280 | Device number of the meter | — | X | — |
115401290 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6401300 | Volume corrector | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001310 | Device number | — | X | — |
711001320 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 DMU01330 | Density volume converter | — | X | — |
7111 TMU01340 | Temperature volume converter | — | X | — |
7111 ZMU01350 | Volume conversion devic e | — | X | — |
| SG10.CAV | — | — | Should | [166] |
7111 ZC001360 | Type of volume measurement | — | X | — |
7110 Z1701370 | Characteristic curve correction | — | X | — |
7110 Z1801380 | Creep flow suppression | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2001390 | OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [78] ∧ [655] |
1153 MG01400 | Device number of the meter | — | X | [442] |
1153 Z1101410 | Device number of the volume converter | — | X | — |
115401420 | Device number | — | X | — |
| SG8.RFF | — | — | Must | [78] |
1153 Z1901430 | Metering location | — | X | — |
115401440 | ID of a metering location | — | X | [951] |
| SG8.PIA | — | — | Must | — |
4347 501450 | Product identification | — | X | — |
714001460 | OBIS code of the metering device | — | X | [324] |
7143 SRW01470 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401480 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD901490 | Annually | — | X | — |
7111 ZE801500 | Semi-annual | — | X | — |
7111 ZE901510 | Quarterly | — | X | — |
7111 ZB701520 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1101530 | Product | — | X | — |
7037 Z3301540 | Integer and decimal places of the register | — | X | — |
| SG10.CAV | — | — | Must | — |
711001550 | Digits before the decimal point | — | X | — |
711001560 | Digits after the decimal point | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0501570 | Communication device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG01580 | Device number of the meter | — | X | — |
115401590 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2601600 | Communication device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001610 | Device number | — | X | — |
711001620 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 GSM01630 | GSM/GPRS/UMTS- comm. dev. | — | X | — |
7111 ETH01640 | Ethernet comm. dev. LAN/WLAN | — | X | — |
7111 PLC01650 | PLC comm. device | — | X | — |
7111 PST01660 | Landline comm. dev. TAE | — | X | — |
7111 DSL01670 | DSL comm. dev. | — | X | — |
7111 LTE01680 | LTE comm. dev. | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1301690 | Smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7501700 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001710 | Device number | — | X | — |
711001720 | Device number | — | X | [952] |
| SG12.NAD | — | — | Must | — |
3035 Z0701730 | Customer of the MSB | — | X | — |
303601740 | Name | — | X | — |
3045 Z0101750 | Structure of person names | — | X | — |
3045 Z0201760 | Structure of the company name | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0801770 | Correspondence address of the customer of the MSB | — | X | — |
303601780 | Name | — | X | — |
3045 Z0101790 | Structure of person names | — | X | — |
3045 Z0201800 | Structure of the company name | — | X | — |
304201810 | Street and house number or PO box | — | X | — |
316401820 | City | — | X | — |
325101830 | Postal code | — | — | M [268] S [166] |
320701840 | Country name, code | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0301850 | Metering location address | — | X | — |
312401860 | Additional information for identification | — | — | — |
304201870 | Street and house number or PO box | — | — | S [166] M [212] |
316401880 | City | — | X | — |
325101890 | Postal code | — | X | — |
320701900 | Country name, code | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0501910 | Name and address for the meter reading card | — | X | — |
303601920 | Name | — | X | — |
3045 Z0101930 | Structure of person names | — | X | — |
3045 Z0201940 | Structure of the company name | — | X | — |
304201950 | Street and house number or PO box | — | X | — |
316401960 | City | — | X | — |
325101970 | Postal code | — | — | M [268] S [166] |
320701980 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1901990 | Metering location | — | X | — |
115402000 | ID of a metering location | — | X | [951] |
| UNT | — | — | Must | — |
007402010 | Number of segments in a message | — | X | — |
006202020 | Message reference number | — | X | — |
Conditions of this table
The free text of the 18 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDG.
| Marker | Condition |
|---|---|
| [78] | If SG4 STS+7++E02 (transaction reason: move-in to creation) is not present |
| [166] | If present |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [249] | Within one SG4 IDE, all DE1131 of the SG4 STS+E01 must contain the identical value |
| [268] | If an "X" is listed for the code in DE3207 in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| [324] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes chapter 4. that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.2 of the document "Code list of configurations" |
| [427] | Metering product code from chapter 3 "Code list of the standard metering products gas" of the code list of configurations |
| [442] | If the device number of the meter named in this RFF DE1154 is present in no SG8+SEQ+Z09 volume converter data in the RFF+MG (reference to the device number) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [621] | Note: The MSB must be specified that is assigned to the location from the point in time named in DTM+76 (date of the planned start of supply). |
| [636] | Note: Using a code in DE1153, this RFF classifies the DTM contained in the same segment group as content relevant to a market location or metering location |
| [655] | Note: If a meter is connected to a volume corrector, no OBIS code numbers are stated at the meter Here there are only OBIS code numbers from the volume corrector |
| [931] | Format: ZZZ = +00 |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [2061] | Segment or segment group must be specified exactly once per SG4 IDE (transaction) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [UB2] | ([931] ∧ [934] [490]) ⊻ ([931] ∧ [935] [491]) |
Example message
UNA:+.? '
UNB+UNOC:3+9870013800007:502+9800110000002:502+{{date}}:{{time}}+447801'
UNH+502814+UTILMD:D:11A:UN:G1.1'
BGM+E01+502814BGM'
DTM+137:202312071336?+00:303'
NAD+MS+9870013800007::332'
NAD+MR+9800110000002::332'
IDE+24+1897808762'
DTM+76:202406010400?+00:303'
STS+7++E03'
STS+E01++E15:G_0054'
LOC+172+DE70016045739G0000000000000042897'
RFF+Z13:44043'
RFF+TN:12345678910'
RFF+Z19:DE70016045739G0000000000000042897'
DTM+752:0101:106'
SEQ+Z18'
RFF+Z19:DE70016045739G0000000000000042897'
CCI+++ZB3'
CAV+Z91:9800110000002::Z19'
CAV+ZF0:9800110000002'
CAV+ZB4:9800172600006'
CCI+++Y02'
CAV+Y04'
CCI+Z32++ZC3'
SEQ+Z19'
PIA+5+9991000000383:Z11'
SEQ+Z03'
RFF+Z19:DE70016045739G0000000000000042897'
CCI+++E13'
CAV+BGZ'
CAV+:::G4'
CAV+Z30:::ABC12345678910'
CCI+++Z28'
CAV+Z31'
CCI+++E12'
CAV+MMR'
SEQ+Z20'
RFF+MG:ABC12345678910'
RFF+Z19:DE70016045739G0000000000000042897'
PIA+5+7-20?:3.0.0:SRW'
CCI+++ZE4'
CAV+ZD9'
CCI+11++Z33'
CAV+:::5:3'
NAD+Z07+++Mustermann:::::Z01'
NAD+Z08+++Mustermann:::::Z01+Str::1+Ort++12345+DE'
NAD+Z03++Mustermann++Str::1+Ort++12345+DE'
NAD+Z05+++Mustermann:::::Z01+Str::1+Ort++12345+DE'
RFF+Z19:DE70016045739G0000000000000042897'
UNT+49+502814'
UNZ+1+447801'[1 item
{6 fields
"data": {3 fields
"stammdaten": {4 fields
"MESSLOKATION": [1 item
{10 fields
"messadresse": {6 fields
"zusatzInformation": {1 field
"zaehlwerke": [1 item
{1 field
"ablesekartenempfaenger": {6 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {5 fields
"marktrollen": [3 items
{5 fields
{4 fields
{4 fields
"NETZNUTZUNGSVERTRAG": [1 item
{7 fields
"vertragskonditionen": {1 field
"geplanteTurnusablesung": {1 field
"MESSSTELLENBETRIEBSVERTRAG": [1 item
{9 fields
"vertragskonditionen": {1 field
"geplanteTurnusablesung": {1 field
"vertragspartner2": [1 item
{5 fields
"geschaeftspartnerrolle": [1 item
"korrespondenzpartner": {5 fields
"partneradresse": {5 fields
"ZAEHLER": [1 item
{11 fields
"zaehlwerke": [1 item
{4 fields
"geraete": [1 item
{1 field
"transaktionsdaten": {15 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | NB | Start of metering point operation | AWH WiM gas 2.0 | Gas | Step 2 |
| MSB | MSBA | Start of metering point operation | AWH WiM gas 2.0 | Gas | Step 2 |
| MSB | MSBN | Start of metering point operation | AWH WiM gas 2.0 | Gas | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Confirmation of registration MSB |
| AHB | UTILMD AHB gas |
| Decision tree | E_2002 (no tree in this format version) |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM gas | Ch. B 3.3 No. 3b | NB → MSBN | Confirmation of the registration |
| AWH WiM gas 2.0 | Start of metering point operation | NB → MSBN | Response to registration |
Individual entries from format version 202610
The check identifiers table of format version 202604 does not carry this entry: decision tree. It comes from version 202610. Version 202610 also carries this check identifier in contexts that the table of version 202604 does not know; they are included in the list above. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202604.
Transaction and responses
Role of this check identifier: response — confirmation. Basis: the transaction data carry antwortstatus and antwortstatusCodeliste; the title or the action of the Prüfi table begins with “response”; the title names a polarity (confirmation).
Request: No reference recorded in the source. Neither the Prüfi table (reaktion_auf) nor the step sequence of the processes names the message that this response answers.
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfragereferenznummer | SG4.IDE+24.SG6.RFF+TN | vorgangsnummer |
For RFF+TN, the field description of the time slice names the »reference transaction number (from request message)« — the target is the vorgangsnummer in segment SG4.IDE+24 of the request. Which request is meant is not determined on this page (see above) — the target field is thus named, but not proven.
Response codes
Decision trees: G_0054 · E_2002.
The Prüfi table names one further tree across all rows of this check identifier. They tie it to a process, not to a row of its handbook — their codes are therefore only on the respective tree page. For G_0054 there is no decision tree in version 202604; its response codes are therefore not given here.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDG has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 273 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type utilmdGas. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.