Check identifier 13013 — Market location-level allocation list gas (MMMA)
Check identifier 13013 · EDIFACT message type MSCONS · Format version 202604
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 13013 | Condition |
|---|---|---|---|---|
| UNB | — | — | Must | — |
0001 UNOC00010 | UN/ECE character set C | — | X | — |
0002 300020 | Version 3 | — | X | — |
000400030 | MP-ID Sender | — | X | — |
0007 1400040 | GS1 | — | X | — |
0007 50200050 | DE, DVGW Service & Consult GmbH | — | X | — |
001000060 | MP-ID recipient | — | X | — |
0007 1400070 | GS1 | — | X | — |
0007 50200080 | DE, DVGW Service & Consult GmbH | — | X | — |
001700090 | Date of creation | — | X | — |
001900100 | Time of creation | — | X | — |
002000110 | Interchange control reference | — | X | [918] |
0026 EM00120 | Energy quantity | — | X | — |
| UNH | — | — | Must | — |
006200130 | Message reference number | — | X | — |
0065 MSCONS00140 | Report on the consumption of measurable services | — | X | — |
0052 D00150 | Draft version | — | X | — |
0054 04B00160 | Edition 2004 - B | — | X | — |
0051 UN00170 | UN/CEFACT | — | X | — |
0057 2.4c00180 | Version number of the underlying BDEW message description | — | X | — |
006800190 | General assignment reference | — | Should | [22] |
007000200 | Transmission sequence number | — | X | — |
0073 C00210 | Start | — | Must | [23] |
0073 F00220 | End | — | Should | [24] |
| BGM | — | — | Must | — |
1001 Z2400230 | Allocation list (MMMA) | — | X | — |
100400240 | Document number | — | X | — |
1225 900250 | Original | — | X | — |
| DTM | — | — | Must | — |
2005 13700260 | Document-/message date/time | — | X | — |
238000270 | Date or time or time span, value | — | X | [931] [494] |
2379 30300280 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 AGI00290 | Application number | — | X | — |
115400300 | Reference number | — | X | [526] |
| SG1.DTM | — | — | Must | — |
2005 29300310 | Completion date/time | — | X | — |
238000320 | Date or time or time span, value | — | X | [931] |
2379 30400330 | CCYYMMDDHHMMSSZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 Z1300340 | Check identifier | — | X | — |
1154 1301300350 | Allocation list gas at market location level (MMMA) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00360 | Document-/message sender or sender | — | X | — |
303900370 | MP-ID | — | X | [118] |
3055 900380 | GS1 | — | X | — |
3055 33200390 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG4.CTA | — | — | Must | — |
3139 IC00400 | Information point | — | X | — |
341200410 | Department or contact person | — | X | — |
| SG4.COM | — | — | Must | — |
314800420 | Communication address, identification | — | X | (([939] [142]) ∨ ([940] [143])) ∧ [576] |
3155 TE00430 | Telephone | — | X | [1P0..1] |
3155 EM00440 | — | X | [1P0..1] | |
3155 AJ00450 | further telephone | — | X | [1P0..1] |
3155 AL00460 | Mobile phone | — | X | [1P0..1] |
3155 FX00470 | Fax number | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00480 | Message recipient | — | X | — |
303900490 | MP-ID | — | X | [118] |
3055 900500 | GS1 | — | X | — |
3055 33200510 | DE, DVGW Service & Consult GmbH | — | X | — |
| UNS | — | — | Must | — |
0081 D00520 | Separation of header and detail section | — | X | — |
| SG5.NAD | — | — | Must | — |
3035 DP00530 | Supply address | — | X | — |
| SG6.LOC | — | — | Must | — |
3227 17200540 | Reporting point | — | X | — |
322500550 | Designation | — | X | [950] [514] |
| SG6.DTM | — | — | Must | — |
2005 49200560 | Balancing date, -time, -period | — | X | — |
238000570 | Date or time or time span, value | — | X | — |
2379 61000580 | CCYYMM | — | X | — |
| SG9.LIN | — | — | Must | — |
108200590 | Line item number | — | X | [908] |
| SG9.PIA | — | — | Must | — |
4347 500600 | Product identification | — | X | — |
714000610 | Medium / OBIS code number | — | X | [501] |
7143 Z0200620 | BDEW OBIS-like code | — | X | — |
| SG10.QTY | — | — | Must | — |
6063 7900630 | Energy quantity totalled (total value, balance total) | — | X | — |
606000640 | Quantity | — | X | [902] ∧ [906] |
| SG10.DTM | — | — | Must | — |
2005 30600650 | Demand period | — | X | — |
238000660 | Date or time or time span, value | — | X | — |
2379 10200670 | CCYYMMDD | — | X | — |
| UNT | — | — | Must | — |
007400680 | Number of segments in a message | — | X | — |
006200690 | Message reference number | — | X | — |
| UNZ | — | — | Must | — |
003600700 | Interchange counter | — | X | — |
002000710 | Interchange control reference | — | X | — |
Conditions of this table
The free text of the 20 conditions referenced by the rows above. All conditions of the message type are listed in the condition index MSCONS.
| Marker | Condition |
|---|---|
| [22] | If a split is present |
| [23] | If UNH DE0070 with 1 is present |
| [24] | In the case of splitting, in the message with the highest transmission number |
| [118] | Only MP-ID from the gas division |
| [142] | if the code EM is present in DE3155 in the same COM |
| [143] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [501] | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| [514] | Note: Use of the ID of the market location |
| [526] | Note: Value from BGM+Z24 DE1004 of the ORDERS with which the allocation list was ordered. |
| [576] | Note: Only one piece of information may be transmitted in DE3148 |
| [902] | Format: Possible value: ≥ 0 |
| [906] | Format: max. 3 decimal places |
| [908] | Format: possible values: 1 to n |
| [918] | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF and NB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Transmission of the market-location-specific allocation list gas | Processes for the determination and billing of excess/shortfall volumes for electricity and gas | Gas | Step 1 |
| NB | NB | Transmission of the market-location-specific allocation list gas | Processes for the determination and billing of excess/shortfall volumes for electricity and gas | Gas | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Allocation list gas at market location level (MMMA) |
| AHB | MSCONS AHB |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| Processes for the determination and billing of excess/shortfall volumes for electricity and gas | Transmission of the market-location-specific allocation list gas | NB → LF | gas allocation list at market location level |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 92 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.