Check identifier 13012 — TEP compar. values reference measurement
Check identifier 13012 · EDIFACT message type MSCONS · Format version 202610
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 13012 | Condition |
|---|---|---|---|---|
| UNB | — | — | Must | — |
0001 UNOC00010 | UN/ECE character set C | — | X | — |
0002 300020 | Version 3 | — | X | — |
000400030 | MP-ID Sender | — | X | — |
0007 1400040 | GS1 | — | X | — |
0007 50000050 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
001000060 | MP-ID recipient | — | X | — |
0007 1400070 | GS1 | — | X | — |
0007 50000080 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
001700090 | Date of creation | — | X | — |
001900100 | Time of creation | — | X | — |
002000110 | Interchange control reference | — | X | [918] |
0026 TL00120 | Load curve, any time period | — | X | — |
0035 100130 | Transmission file is a test | — | — | S [155] |
| UNH | — | — | Must | — |
006200140 | Message reference number | — | X | — |
0065 MSCONS00150 | Report on the consumption of measurable services | — | X | — |
0052 D00160 | Draft version | — | X | — |
0054 04B00170 | Edition 2004 - B | — | X | — |
0051 UN00180 | UN/CEFACT | — | X | — |
0057 2.500190 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z2000200 | Historical values for TEP with reference measurement | — | X | — |
100400210 | Document number | — | X | — |
1225 900220 | Original | — | X | — |
| DTM | — | — | Must | — |
2005 13700230 | Document-/message date/time | — | X | — |
238000240 | Date or time or time span, value | — | X | [931] [494] |
2379 30300250 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 Z1300260 | Check identifier | — | X | — |
1154 1301200270 | TEP historical values reference measurement | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00280 | Document-/message sender or sender | — | X | — |
303900290 | MP-ID | — | X | [117] |
3055 900300 | GS1 | — | X | — |
3055 29300310 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00320 | Message recipient | — | X | — |
303900330 | MP-ID | — | X | [117] |
3055 900340 | GS1 | — | X | — |
3055 29300350 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| UNS | — | — | Must | — |
0081 D00360 | Separation of header and detail section | — | X | — |
| SG5.NAD | — | — | Must | — |
3035 DED00370 | Profile creation | — | X | — |
| SG6.LOC | — | — | Must | — |
3227 Z0400380 | Profile name | — | X | — |
322500390 | Designation | — | X | [905] [515] |
| SG6.DTM | — | — | Must | [2] |
2005 29300400 | Completion date/time | — | X | — |
238000410 | Date or time or time span, value | — | X | [931] |
2379 30400420 | CCYYMMDDHHMMSSZZZ | — | X | — |
| SG9.LIN | — | — | Must | — |
108200430 | Line item number | — | X | [908] |
| SG9.PIA | — | — | Must | — |
4347 500440 | Product identification | — | X | — |
714000450 | Medium / OBIS code number | — | X | [501] |
7143 SRW00460 | OBIS code | — | X | — |
| SG10.QTY | — | — | Must | — |
6063 18700470 | Forecast value | — | X | — |
606000480 | Quantity | — | X | [902] ∧ [906] |
| SG10.DTM | — | — | Must | — |
2005 16300490 | Processing, start date/time | — | X | — |
238000500 | Date or time or time span, value | — | X | [931] |
2379 30300510 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | — |
2005 16400520 | Processing, end date/time | — | X | — |
238000530 | Date or time or time span, value | — | X | [931] |
2379 30300540 | CCYYMMDDHHMMZZZ | — | X | — |
| UNT | — | — | Must | — |
007400550 | Number of segments in a message | — | X | — |
006200560 | Message reference number | — | X | — |
| UNZ | — | — | Must | — |
003600570 | Interchange counter | — | X | — |
002000580 | Interchange control reference | — | X | — |
Conditions of this table
The free text of the 12 conditions referenced by the rows above. All conditions of the message type are listed in the condition index MSCONS.
| Marker | Condition |
|---|---|
| [2] | If the time interval between the first SG10 DTM+163 and the last SG10 DTM+164 spans at least one month |
| [117] | Only MP-ID from the electricity division |
| [155] | If the transmission file is exchanged for test purposes. |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [501] | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| [515] | Note: Use of the profile designation |
| [902] | Format: Possible value: ≥ 0 |
| [905] | Format: max. 3 digits |
| [906] | Format: max. 3 decimal places |
| [908] | Format: possible values: 1 to n |
| [918] | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| [931] | Format: ZZZ = +00 |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Transmission of standardized profiles and profile sets from the NB to LF or ÜNB | MaBiS | Electricity | Step 1 |
| NB | NB | Transmission of standardized profiles and profile sets from the NB to LF or ÜNB | MaBiS | Electricity | Step 1 |
| NB | NB | Transmission of standardized profiles from the NB to MSB | MaBiS | Electricity | Step 1 |
| MSB | MSB | Transmission of standardized profiles from the NB to MSB | MaBiS | Electricity | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | TEP comp. values reference measurement |
| AHB | MSCONS AHB |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Transmission of standardized profiles from NB to MSB | NB → MSB | Transmission of the normalised profiles |
| MaBiS | Transmission of standardized profiles and profile sets from NB to LF or ÜNB | NB → LF | Transmission of the subscribed standardised profiles or profile sets |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 76 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.