Check identifier 13025 — Load curve market location, tranche
Check identifier 13025 · EDIFACT message type MSCONS · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 13025 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| ENERGIEMENGE [ ] * | — | object[] | Must | — |
| enddatum * 00010 | Specifies the day and time (if available) when the time period ends. | string (date-time) | X | — |
| konfiguration 00020 | konfiguration | string | X | — |
| lokationsId * 00030 | Unique number of the market location or of the metering location to which the energy quantity belongs | string | X | — |
| startdatum * 00040 | Specifies the day and time (if available) when the time period starts. | string (date-time) | X | — |
| energieverbrauch [ ] * | — | object[] | Must | — |
| enddatum * 00050 | enddatum | string (date-time) | X | — |
| messwertstatus * 00060 | The status of a meter reading | Enum Messwertstatus | Must | — |
ABGELESEN | — | — | Must | — |
ERSATZWERT | — | — | Must | — |
VORSCHLAGSWERT | — | — | Must | — |
NICHT_VERWENDBAR | — | — | Must | — |
PROGNOSEWERT | — | — | Must | — |
ENERGIEMENGESUMMIERT | — | — | Must | — |
VOLAEUFIGERWERT | — | — | Must | — |
FEHLT | — | — | Must | — |
ANGABE_FUER_LIEFERSCHEIN | — | — | Must | — |
GRUNDLAGE_POG_ERMITTLUNG | — | — | Must | — |
| obiskennzahl * 00070 | obiskennzahl | string | X | — |
| position * 00080 | position | integer | Must | — |
| startdatum * 00090 | startdatum | string (date-time) | X | — |
| wert * 00100 | wert | number (float) | Must | — |
| statuszusatzinformationen [ ] | — | object[] | May | — |
| art 00110 | Status type | Enum StatusArt | X | — |
PLAUSIBILISIERUNGSHINWEIS | — | — | X | — |
ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
KORREKTURGRUND | — | — | X | — |
GRUND_ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
GASQUALITAET | — | — | X | — |
MESSKLASSIFIZIERUNG | — | — | X | — |
| status 00120 | Status | Enum Status | X | — |
KUNDENSELBSTABLESUNG | — | — | X | — |
LEERSTAND | — | — | X | — |
REALER_ZAEHLERUEBERLAUF_GEPRUEFT | — | — | X | — |
PLAUSIBEL_WG_KONTROLLABLESUNG | — | — | X | — |
PLAUSIBEL_WG_KUNDENHINWEIS | — | — | X | — |
AUSTAUSCH_DES_ERSATZWERTES | — | — | X | — |
RECHENWERT | — | — | X | — |
BASIS_MME | — | — | X | — |
VERGLEICHSMESSUNG_GEEICHT | — | — | X | — |
VERGLEICHSMESSUNG_NICHT_GEEICHT | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_GEEICHTEN_WERTEN | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_NICHT_GEEICHTEN_WERTEN | — | — | X | — |
INTERPOLATION | — | — | X | — |
HALTEWERT | — | — | X | — |
BILANZIERUNG_NETZABSCHNITT | — | — | X | — |
HISTORISCHE_MESSWERTE | — | — | X | — |
STATISTISCHE_METHODE | — | — | X | — |
AUFTEILUNG | — | — | X | — |
VERWENDUNG_VON_WERTEN_DES_STOERMENGENZAEHLWERKS | — | — | X | — |
UMGANGS_UND_KORREKTURMENGEN | — | — | X | — |
ANGABEN_MESSLOKATION | — | — | X | — |
KEIN_ZUGANG | — | — | X | — |
KOMMUNIKATIONSSTOERUNG | — | — | X | — |
NETZAUSFALL | — | — | X | — |
SPANNUNGSAUSFALL | — | — | X | — |
STATUS_GERAETEWECHSEL | — | — | X | — |
KALIBRIERUNG | — | — | X | — |
GERAET_ARBEITET_AUSSERHALB_DER_BETRIEBSBEDINGUNGEN | — | — | X | — |
MESSEINRICHTUNG_GESTOERT_DEFEKT | — | — | X | — |
UNSICHERHEIT_MESSUNG | — | — | X | — |
BERUECKSICHTIGUNG_STOERMENGENZAEHLWERK | — | — | X | — |
MENGENUMWERTUNG_VOLLSTAENDIG | — | — | X | — |
UHRZEIT_GESTELLT_SYNCHRONISATION | — | — | X | — |
MESSWERT_UNPLAUSIBEL | — | — | X | — |
FALSCHER_WANDLERFAKTOR | — | — | X | — |
FEHLERHAFTE_ABLESUNG | — | — | X | — |
AENDERUNG_DER_BERECHNUNG | — | — | X | — |
UMBAU_DER_MESSLOKATION | — | — | X | — |
DATENBEARBEITUNGSFEHLER | — | — | X | — |
BRENNWERTKORREKTUR | — | — | X | — |
Z_ZAHL_KORREKTUR | — | — | X | — |
STOERUNG_DEFEKT_MESSEINRICHTUNG | — | — | X | — |
AENDERUNG_TARIFSCHALTZEITEN | — | — | X | — |
TARIFSCHALTGERAET_DEFEKT | — | — | X | — |
IMPULSWERTIGKEIT_NICHT_AUSREICHEND | — | — | X | — |
ENERGIEMENGE_IN_UNGEMESSENEM_ZEITINTERVALL | — | — | X | — |
ENERGIEMENGE_AUS_DEM_UNGEPAIRTEN_ZEITINTERVALL | — | — | X | — |
WARTUNGSARBEITEN_AN_GEEICHTEM_MESSGERAET | — | — | X | — |
GESTOERTE_WERTE | — | — | X | — |
WARTUNGSARBEITEN_AN_EICHRECHTSKONFORMEN_MESSGERAETEN | — | — | X | — |
KONSISTENZ_UND_SYNCHRONPRUEFUNG | — | — | X | — |
GRUND_ANGABEN_MESSLOKATION | — | — | X | — |
ANFORDERUNG_IN_DIE_VERGANGENHEIT_ZUM_ANGEFORDERTEN_ZEITPUNKT_LIEGT_KEIN_WERT_VOR | — | — | X | — |
UMSTELLUNG_GASQUALITAET | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
GESCHEITERT | — | — | X | — |
AUSGEBAUT | — | — | X | — |
| transaktionsdaten * | — | object | Must | — |
| anfrageReferenz 00130 | Application number / RFF+AGI | string | X | — |
| dokumentennummer * 00140 | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| kategorie * 00150 | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| nachrichtendatum * 00160 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenfunktion * 00170 | Message function code / BGM | string | Must | — |
| nachrichtenreferenznummer * 00180 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00190 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00200 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00210 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00220 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00230 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 13025 | Condition |
|---|---|---|---|---|
| UNB | — | — | Must | — |
0001 UNOC00010 | UN/ECE character set C | — | X | — |
0002 300020 | Version 3 | — | X | — |
000400030 | MP-ID Sender | — | X | — |
0007 1400040 | GS1 | — | X | — |
0007 50000050 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
001000060 | MP-ID recipient | — | X | — |
0007 1400070 | GS1 | — | X | — |
0007 50000080 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
001700090 | Date of creation | — | X | — |
001900100 | Time of creation | — | X | — |
002000110 | Interchange control reference | — | X | [918] |
0026 TL00120 | Load curve, any time period | — | X | — |
0035 100130 | Transmission file is a test | — | — | S [155] |
| UNH | — | — | Must | — |
006200140 | Message reference number | — | X | — |
0065 MSCONS00150 | Report on the consumption of measurable services | — | X | — |
0052 D00160 | Draft version | — | X | — |
0054 04B00170 | Edition 2004 - B | — | X | — |
0051 UN00180 | UN/CEFACT | — | X | — |
0057 2.500190 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z4800200 | Load curve market location, tranche | — | X | — |
100400210 | Document number | — | X | — |
1225 900220 | Original | — | X | — |
| DTM | — | — | Must | — |
2005 13700230 | Document-/message date/time | — | X | — |
238000240 | Date or time or time span, value | — | X | [931] [494] |
2379 30300250 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 AGI00260 | Application number | — | X | — |
115400270 | Reference number | — | X | [529] ∨ [553] |
| SG1.RFF | — | — | Must | — |
1153 Z1300280 | Check identifier | — | X | — |
1154 1302500290 | Load curve market location, tranche | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00300 | Document-/message sender or sender | — | X | — |
303900310 | MP-ID | — | X | [117] |
3055 900320 | GS1 | — | X | — |
3055 29300330 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00340 | Message recipient | — | X | — |
303900350 | MP-ID | — | X | [117] |
3055 900360 | GS1 | — | X | — |
3055 29300370 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| UNS | — | — | Must | — |
0081 D00380 | Separation of header and detail section | — | X | — |
| SG5.NAD | — | — | Must | — |
3035 DP00390 | Supply address | — | X | — |
| SG6.LOC | — | — | Must | — |
3227 17200400 | Reporting point | — | X | — |
322500410 | Designation | — | X | [950] (([514] ∨ [518]) ∧ ([35] ∨ ([32] ∧ [77]))) |
| SG6.DTM | — | — | Must | — |
2005 16300420 | Processing, start date/time | — | X | — |
238000430 | Date or time or time span, value | — | X | [931] |
2379 30300440 | CCYYMMDDHHMMZZZ | — | X | — |
| SG6.DTM | — | — | Must | — |
2005 16400450 | Processing, end date/time | — | X | — |
238000460 | Date or time or time span, value | — | X | [931] |
2379 30300470 | CCYYMMDDHHMMZZZ | — | X | — |
| SG9.LIN | — | — | Must | — |
108200480 | Line item number | — | X | [908] |
| SG9.PIA | — | — | Must | — |
4347 500490 | Product identification | — | X | — |
714000500 | Medium / OBIS code number | — | X | [501] ∧ [566] |
7143 SRW00510 | OBIS code | — | X | — |
| SG10.QTY | — | — | Must | — |
6063 22000520 | True value | — | X | — |
6063 6700530 | Substitute value | — | X | [35] ∨ ([32] ∧ [77]) |
6063 Z1800540 | Preliminary value | — | X | [35] |
606000550 | Quantity | — | X | [902] ∧ [906] |
| SG10.DTM | — | — | Must | — |
2005 16300560 | Processing, start date/time | — | X | — |
238000570 | Date or time or time span, value | — | X | [931] [495] |
2379 30300580 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | — |
2005 16400590 | Processing, end date/time | — | X | — |
238000600 | Date or time or time span, value | — | X | [931] [495] |
2379 30300610 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.STS | — | — | Should | ([92] ⊻ [93]) ∧ [126] |
9015 Z3300620 | Plausibility check note | — | X | — |
9013 Z8300630 | Customer self-reading | — | X | [5P0..1] |
9013 Z8400640 | Vacancy | — | X | [4P0..1] ⊻ [5P0..1] |
9013 Z8500650 | Actual meter overflow checked | — | X | [4P0..1] ⊻ [5P0..1] |
9013 Z8600660 | Plausible due to check reading | — | X | [4P0..1] ⊻ [5P0..1] |
9013 Z8700670 | Plausible due to customer information | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZC300680 | Exchange of the substitute value | — | X | [4P0..1] ⊻ [5P0..1] |
| SG10.STS | — | — | Must | [92] |
9015 Z3200690 | Substitute value formation procedure | — | X | — |
9013 Z8800700 | Comparative measurement (calibrated) | — | X | [4P0..1] |
9013 Z8900710 | Comparative measurement (not calibrated) | — | X | [4P0..1] |
9013 Z9200720 | Interpolation | — | X | [4P0..1] |
9013 ZJ200730 | Statistical method | — | X | [4P0..1] |
9013 ZS000740 | Substitute value procedure according to the details at the level of the metering location | — | X | [46] ∧ [568] |
| SG10.STS | — | — | Should | [127] ∧ [551] |
9015 Z3400750 | Reason for correction | — | X | — |
9013 Z7400760 | no access | — | X | [4P0..1] |
9013 Z7500770 | Communication fault | — | X | [4P0..1] |
9013 Z7600780 | Grid outage | — | X | [4P0..1] |
9013 Z7700790 | Voltage failure | — | X | [4P0..1] |
9013 Z7800800 | Device replacement | — | X | [4P0..1] |
9013 Z7900810 | Calibration | — | X | [4P0..1] |
9013 Z8000820 | Device operates outside the operating conditions | — | X | [4P0..1] |
9013 Z8100830 | Measuring equipment faulty/defective | — | X | [4P0..1] |
9013 Z8200840 | Measurement uncertainty | — | X | [4P0..1] |
9013 ZA000850 | Time set /synchronisation | — | X | [4P0..1] |
9013 ZA100860 | Meter reading value implausible | — | X | [4P0..1] |
9013 ZA300870 | Incorrect transformer factor | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA400880 | Incorrect reading | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA500890 | Change of the calculation | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA600900 | Conversion of the metering location | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA700910 | Data processing error | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZB000920 | Fault / defect of measuring equipment | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZB900930 | Change tariff switching times | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZC200940 | Tariff switching device defective | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZC400950 | Pulse value not sufficient | — | X | [4P0..1] |
| SG10.STS | — | — | Must | [92] |
9015 Z4000960 | Reason for substitute value formation | — | X | — |
9013 Z7400970 | no access | — | X | [4P0..1] |
9013 Z7500980 | Communication fault | — | X | [4P0..1] |
9013 Z7600990 | Grid outage | — | X | [4P0..1] |
9013 Z7701000 | Voltage failure | — | X | [4P0..1] |
9013 Z7801010 | Device replacement | — | X | [4P0..1] |
9013 Z7901020 | Calibration | — | X | [4P0..1] |
9013 Z8001030 | Device operates outside the operating conditions | — | X | [4P0..1] |
9013 Z8101040 | Measuring equipment faulty/defective | — | X | [4P0..1] |
9013 Z8201050 | Measurement uncertainty | — | X | [4P0..1] |
9013 ZA001060 | Time set /synchronisation | — | X | [4P0..1] |
9013 ZA101070 | Meter reading value implausible | — | X | [4P0..1] |
9013 ZA301080 | Incorrect transformer factor | — | X | [4P0..1] |
9013 ZA401090 | Incorrect reading | — | X | [4P0..1] |
9013 ZA501100 | Change of the calculation | — | X | [4P0..1] |
9013 ZA601110 | Conversion of the metering location | — | X | [4P0..1] |
9013 ZA701120 | Data processing error | — | X | [4P0..1] |
9013 ZB001130 | Fault / defect of measuring equipment | — | X | [4P0..1] |
9013 ZB901140 | Change tariff switching times | — | X | [4P0..1] |
9013 ZC201150 | Tariff switching device defective | — | X | [4P0..1] |
9013 ZC401160 | Pulse value not sufficient | — | X | [4P0..1] |
9013 ZS901170 | Reason for substitute value formation according to the information at metering location level | — | X | [46] ∧ [570] |
| UNT | — | — | Must | — |
007401180 | Number of segments in a message | — | X | — |
006201190 | Message reference number | — | X | — |
| UNZ | — | — | Must | — |
003601200 | Interchange counter | — | X | — |
002001210 | Interchange control reference | — | X | — |
Conditions of this table
The free text of the 29 conditions referenced by the rows above. All conditions of the message type are listed in the condition index MSCONS.
| Marker | Condition |
|---|---|
| [32] | if MP-ID in SG2 NAD+MS in the role NB |
| [35] | if MP-ID in SG2 NAD+MS in the role MSB |
| [46] | If the value in SG6 LOC+172 DE3225 has exactly 11 digits |
| [77] | If MP-ID in SG2 NAD+MR of the RB HKN-R |
| [92] | If SG10 QTY DE6063 with value 67 is present |
| [93] | If SG10 QTY DE6063 with value 220 is present |
| [117] | Only MP-ID from the electricity division |
| [126] | if plausibility check notices exist |
| [127] | if a correction reason has to be stated |
| [155] | If the transmission file is exchanged for test purposes. |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [501] | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| [514] | Note: Use of the ID of the market location |
| [518] | Note: Use of the ID of the tranche |
| [529] | Note: Value from BGM+7 DE1004 of the ORDERS with which the request for meter reading values was made. |
| [551] | Note: A correction reason is to be specified if: 1. a preliminary value already transmitted to the MP is replaced by a substitute value, or 2. a substitute value already transmitted to the MP is replaced by a substitute value, or 3. a true value already transmitted to the MP is replaced by a substitute value, or 4. a true value already transmitted to the MP is replaced by a true value. |
| [553] | Note: Value from BGM+Z34 DE1004 of the ORDERS with which the complaint regarding values was made |
| [566] | Note: Only the values that were transmitted by the MSB in the previous master data exchange for this reporting point at the point in time are permitted. |
| [568] | Note: Use is permitted only if it is a 1:n relationship between market and metering location and different substitute value determination procedures have been used and communicated at the level of the metering location. |
| [570] | Note: Use is permitted only if it is a 1:n relationship between market and metering location and different reasons for the substitute value determination exist at the level of the metering location and have been communicated. |
| [902] | Format: Possible value: ≥ 0 |
| [906] | Format: max. 3 decimal places |
| [908] | Format: possible values: 1 to n |
| [918] | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| [931] | Format: ZZZ = +00 |
| [950] | Format: market location ID |
| [5P0..1] | [93] If SG10 QTY DE6063 with value 220 present |
| [4P0..1] | [92] If SG10 QTY DE6063 with value 67 present |
Example message
UNA:+.? '
UNB+UNOC:3+9904545000007:500+9911694000002:500+{{date}}:{{time}}+K21E0D864ED9++TL'
UNH+1+MSCONS:D:04B:UN:2.5'
BGM+Z48+K21E0D864ED90+9'
DTM+137:202610011100?+00:303'
RFF+Z13:13025'
NAD+MS+9904545000007::293'
NAD+MR+9911694000002::293'
UNS+D'
NAD+DP'
LOC+172+51580175011'
DTM+163:202310052200?+00:303'
DTM+164:202310062200?+00:303'
LIN+1'
PIA+5+1-1?:3.29.0:SRW'
QTY+220:0'
DTM+163:202310052200?+00:303'
DTM+164:202310052215?+00:303'
QTY+220:0'
DTM+163:202310052215?+00:303'
DTM+164:202310052230?+00:303'
QTY+220:0'
DTM+163:202310052230?+00:303'
DTM+164:202310052245?+00:303'
QTY+220:0'
DTM+163:202310052245?+00:303'
DTM+164:202310052300?+00:303'
QTY+220:0'
DTM+163:202310052300?+00:303'
DTM+164:202310052315?+00:303'
QTY+220:0'
DTM+163:202310052315?+00:303'
DTM+164:202310052330?+00:303'
QTY+220:0'
DTM+163:202310052330?+00:303'
DTM+164:202310052345?+00:303'
QTY+220:0'
DTM+163:202310052345?+00:303'
DTM+164:202310060000?+00:303'
QTY+220:0'
DTM+163:202310060000?+00:303'
DTM+164:202310060015?+00:303'
QTY+220:0'
DTM+163:202310060015?+00:303'
DTM+164:202310060030?+00:303'
QTY+220:0'
DTM+163:202310060030?+00:303'
DTM+164:202310060045?+00:303'
QTY+220:0'
DTM+163:202310060045?+00:303'
DTM+164:202310060100?+00:303'
QTY+220:0'
DTM+163:202310060100?+00:303'
DTM+164:202310060115?+00:303'
QTY+220:0'
DTM+163:202310060115?+00:303'
DTM+164:202310060130?+00:303'
QTY+220:0'
DTM+163:202310060130?+00:303'
DTM+164:202310060145?+00:303'
QTY+220:0'
DTM+163:202310060145?+00:303'
DTM+164:202310060200?+00:303'
QTY+220:0'
DTM+163:202310060200?+00:303'
DTM+164:202310060215?+00:303'
QTY+220:0'
DTM+163:202310060215?+00:303'
DTM+164:202310060230?+00:303'
QTY+220:0'
DTM+163:202310060230?+00:303'
DTM+164:202310060245?+00:303'
QTY+220:0'
DTM+163:202310060245?+00:303'
DTM+164:202310060300?+00:303'
QTY+220:0'
DTM+163:202310060300?+00:303'
DTM+164:202310060315?+00:303'
QTY+220:0'
DTM+163:202310060315?+00:303'
DTM+164:202310060330?+00:303'
QTY+220:0'
DTM+163:202310060330?+00:303'
DTM+164:202310060345?+00:303'
QTY+220:0'
DTM+163:202310060345?+00:303'
DTM+164:202310060400?+00:303'
QTY+220:0'
DTM+163:202310060400?+00:303'
DTM+164:202310060415?+00:303'
QTY+220:0'
DTM+163:202310060415?+00:303'
DTM+164:202310060430?+00:303'
QTY+220:0.012'
DTM+163:202310060430?+00:303'
DTM+164:202310060445?+00:303'
QTY+220:0'
DTM+163:202310060445?+00:303'
DTM+164:202310060500?+00:303'
QTY+220:0.188'
DTM+163:202310060500?+00:303'
DTM+164:202310060515?+00:303'
QTY+220:0.388'
DTM+163:202310060515?+00:303'
DTM+164:202310060530?+00:303'
QTY+220:0'
DTM+163:202310060530?+00:303'
DTM+164:202310060545?+00:303'
QTY+220:0.075'
DTM+163:202310060545?+00:303'
DTM+164:202310060600?+00:303'
QTY+220:0.012'
DTM+163:202310060600?+00:303'
DTM+164:202310060615?+00:303'
QTY+220:0'
DTM+163:202310060615?+00:303'
DTM+164:202310060630?+00:303'
QTY+220:0'
DTM+163:202310060630?+00:303'
DTM+164:202310060645?+00:303'
QTY+220:0'
DTM+163:202310060645?+00:303'
DTM+164:202310060700?+00:303'
QTY+220:0'
DTM+163:202310060700?+00:303'
DTM+164:202310060715?+00:303'
QTY+220:0.088'
DTM+163:202310060715?+00:303'
DTM+164:202310060730?+00:303'
QTY+220:0.975'
DTM+163:202310060730?+00:303'
DTM+164:202310060745?+00:303'
QTY+220:0.175'
DTM+163:202310060745?+00:303'
DTM+164:202310060800?+00:303'
QTY+220:0.162'
DTM+163:202310060800?+00:303'
DTM+164:202310060815?+00:303'
QTY+220:0'
DTM+163:202310060815?+00:303'
DTM+164:202310060830?+00:303'
QTY+220:0'
DTM+163:202310060830?+00:303'
DTM+164:202310060845?+00:303'
QTY+220:0.088'
DTM+163:202310060845?+00:303'
DTM+164:202310060900?+00:303'
QTY+220:0.175'
DTM+163:202310060900?+00:303'
DTM+164:202310060915?+00:303'
QTY+220:0.3'
DTM+163:202310060915?+00:303'
DTM+164:202310060930?+00:303'
QTY+220:0.225'
DTM+163:202310060930?+00:303'
DTM+164:202310060945?+00:303'
QTY+220:0.375'
DTM+163:202310060945?+00:303'
DTM+164:202310061000?+00:303'
QTY+220:0'
DTM+163:202310061000?+00:303'
DTM+164:202310061015?+00:303'
QTY+220:0'
DTM+163:202310061015?+00:303'
DTM+164:202310061030?+00:303'
QTY+220:0'
DTM+163:202310061030?+00:303'
DTM+164:202310061045?+00:303'
QTY+220:0.012'
DTM+163:202310061045?+00:303'
DTM+164:202310061100?+00:303'
QTY+220:0'
DTM+163:202310061100?+00:303'
DTM+164:202310061115?+00:303'
QTY+220:0'
DTM+163:202310061115?+00:303'
DTM+164:202310061130?+00:303'
QTY+220:0'
DTM+163:202310061130?+00:303'
DTM+164:202310061145?+00:303'
QTY+220:0.125'
DTM+163:202310061145?+00:303'
DTM+164:202310061200?+00:303'
QTY+220:0.138'
DTM+163:202310061200?+00:303'
DTM+164:202310061215?+00:303'
QTY+220:0'
DTM+163:202310061215?+00:303'
DTM+164:202310061230?+00:303'
QTY+220:0'
DTM+163:202310061230?+00:303'
DTM+164:202310061245?+00:303'
QTY+220:0'
DTM+163:202310061245?+00:303'
DTM+164:202310061300?+00:303'
QTY+220:0'
DTM+163:202310061300?+00:303'
DTM+164:202310061315?+00:303'
QTY+220:0'
DTM+163:202310061315?+00:303'
DTM+164:202310061330?+00:303'
QTY+220:0'
DTM+163:202310061330?+00:303'
DTM+164:202310061345?+00:303'
QTY+220:0'
DTM+163:202310061345?+00:303'
DTM+164:202310061400?+00:303'
QTY+220:0'
DTM+163:202310061400?+00:303'
DTM+164:202310061415?+00:303'
QTY+220:0'
DTM+163:202310061415?+00:303'
DTM+164:202310061430?+00:303'
QTY+220:0'
DTM+163:202310061430?+00:303'
DTM+164:202310061445?+00:303'
QTY+220:0'
DTM+163:202310061445?+00:303'
DTM+164:202310061500?+00:303'
QTY+220:0'
DTM+163:202310061500?+00:303'
DTM+164:202310061515?+00:303'
QTY+220:0'
DTM+163:202310061515?+00:303'
DTM+164:202310061530?+00:303'
QTY+220:0'
DTM+163:202310061530?+00:303'
DTM+164:202310061545?+00:303'
QTY+220:0'
DTM+163:202310061545?+00:303'
DTM+164:202310061600?+00:303'
QTY+220:0'
DTM+163:202310061600?+00:303'
DTM+164:202310061615?+00:303'
QTY+220:0'
DTM+163:202310061615?+00:303'
DTM+164:202310061630?+00:303'
QTY+220:0'
DTM+163:202310061630?+00:303'
DTM+164:202310061645?+00:303'
QTY+220:0'
DTM+163:202310061645?+00:303'
DTM+164:202310061700?+00:303'
QTY+220:0'
DTM+163:202310061700?+00:303'
DTM+164:202310061715?+00:303'
QTY+220:0'
DTM+163:202310061715?+00:303'
DTM+164:202310061730?+00:303'
QTY+220:0'
DTM+163:202310061730?+00:303'
DTM+164:202310061745?+00:303'
QTY+220:0'
DTM+163:202310061745?+00:303'
DTM+164:202310061800?+00:303'
QTY+220:0'
DTM+163:202310061800?+00:303'
DTM+164:202310061815?+00:303'
QTY+220:0'
DTM+163:202310061815?+00:303'
DTM+164:202310061830?+00:303'
QTY+220:0'
DTM+163:202310061830?+00:303'
DTM+164:202310061845?+00:303'
QTY+220:0'
DTM+163:202310061845?+00:303'
DTM+164:202310061900?+00:303'
QTY+220:0'
DTM+163:202310061900?+00:303'
DTM+164:202310061915?+00:303'
QTY+220:0'
DTM+163:202310061915?+00:303'
DTM+164:202310061930?+00:303'
QTY+220:0'
DTM+163:202310061930?+00:303'
DTM+164:202310061945?+00:303'
QTY+220:0'
DTM+163:202310061945?+00:303'
DTM+164:202310062000?+00:303'
QTY+220:0'
DTM+163:202310062000?+00:303'
DTM+164:202310062015?+00:303'
QTY+220:0'
DTM+163:202310062015?+00:303'
DTM+164:202310062030?+00:303'
QTY+220:0'
DTM+163:202310062030?+00:303'
DTM+164:202310062045?+00:303'
QTY+220:0'
DTM+163:202310062045?+00:303'
DTM+164:202310062100?+00:303'
QTY+220:0'
DTM+163:202310062100?+00:303'
DTM+164:202310062115?+00:303'
QTY+220:0'
DTM+163:202310062115?+00:303'
DTM+164:202310062130?+00:303'
QTY+220:0'
DTM+163:202310062130?+00:303'
DTM+164:202310062145?+00:303'
QTY+220:0'
DTM+163:202310062145?+00:303'
DTM+164:202310062200?+00:303'
LIN+2'
PIA+5+1-1?:1.29.0:SRW'
QTY+220:0.725'
DTM+163:202310052200?+00:303'
DTM+164:202310052215?+00:303'
QTY+220:0.75'
DTM+163:202310052215?+00:303'
DTM+164:202310052230?+00:303'
QTY+220:0.738'
DTM+163:202310052230?+00:303'
DTM+164:202310052245?+00:303'
QTY+220:1.388'
DTM+163:202310052245?+00:303'
DTM+164:202310052300?+00:303'
QTY+220:1.175'
DTM+163:202310052300?+00:303'
DTM+164:202310052315?+00:303'
QTY+220:0.762'
DTM+163:202310052315?+00:303'
DTM+164:202310052330?+00:303'
QTY+220:0.75'
DTM+163:202310052330?+00:303'
DTM+164:202310052345?+00:303'
QTY+220:0.725'
DTM+163:202310052345?+00:303'
DTM+164:202310060000?+00:303'
QTY+220:0.738'
DTM+163:202310060000?+00:303'
DTM+164:202310060015?+00:303'
QTY+220:0.762'
DTM+163:202310060015?+00:303'
DTM+164:202310060030?+00:303'
QTY+220:0.762'
DTM+163:202310060030?+00:303'
DTM+164:202310060045?+00:303'
QTY+220:0.8'
DTM+163:202310060045?+00:303'
DTM+164:202310060100?+00:303'
QTY+220:0.75'
DTM+163:202310060100?+00:303'
DTM+164:202310060115?+00:303'
QTY+220:0.738'
DTM+163:202310060115?+00:303'
DTM+164:202310060130?+00:303'
QTY+220:0.788'
DTM+163:202310060130?+00:303'
DTM+164:202310060145?+00:303'
QTY+220:0.738'
DTM+163:202310060145?+00:303'
DTM+164:202310060200?+00:303'
QTY+220:0.712'
DTM+163:202310060200?+00:303'
DTM+164:202310060215?+00:303'
QTY+220:0.825'
DTM+163:202310060215?+00:303'
DTM+164:202310060230?+00:303'
QTY+220:0.838'
DTM+163:202310060230?+00:303'
DTM+164:202310060245?+00:303'
QTY+220:1.112'
DTM+163:202310060245?+00:303'
DTM+164:202310060300?+00:303'
QTY+220:5.038'
DTM+163:202310060300?+00:303'
DTM+164:202310060315?+00:303'
QTY+220:3.5'
DTM+163:202310060315?+00:303'
DTM+164:202310060330?+00:303'
QTY+220:4.2'
DTM+163:202310060330?+00:303'
DTM+164:202310060345?+00:303'
QTY+220:1.388'
DTM+163:202310060345?+00:303'
DTM+164:202310060400?+00:303'
QTY+220:1.575'
DTM+163:202310060400?+00:303'
DTM+164:202310060415?+00:303'
QTY+220:1.475'
DTM+163:202310060415?+00:303'
DTM+164:202310060430?+00:303'
QTY+220:2.638'
DTM+163:202310060430?+00:303'
DTM+164:202310060445?+00:303'
QTY+220:3.712'
DTM+163:202310060445?+00:303'
DTM+164:202310060500?+00:303'
QTY+220:3.538'
DTM+163:202310060500?+00:303'
DTM+164:202310060515?+00:303'
QTY+220:2.5'
DTM+163:202310060515?+00:303'
DTM+164:202310060530?+00:303'
QTY+220:1.888'
DTM+163:202310060530?+00:303'
DTM+164:202310060545?+00:303'
QTY+220:2.062'
DTM+163:202310060545?+00:303'
DTM+164:202310060600?+00:303'
QTY+220:1.9'
DTM+163:202310060600?+00:303'
DTM+164:202310060615?+00:303'
QTY+220:1.912'
DTM+163:202310060615?+00:303'
DTM+164:202310060630?+00:303'
QTY+220:1.65'
DTM+163:202310060630?+00:303'
DTM+164:202310060645?+00:303'
QTY+220:1.788'
DTM+163:202310060645?+00:303'
DTM+164:202310060700?+00:303'
QTY+220:1.325'
DTM+163:202310060700?+00:303'
DTM+164:202310060715?+00:303'
QTY+220:2.262'
DTM+163:202310060715?+00:303'
DTM+164:202310060730?+00:303'
QTY+220:5.375'
DTM+163:202310060730?+00:303'
DTM+164:202310060745?+00:303'
QTY+220:3.962'
DTM+163:202310060745?+00:303'
DTM+164:202310060800?+00:303'
QTY+220:4.338'
DTM+163:202310060800?+00:303'
DTM+164:202310060815?+00:303'
QTY+220:2.388'
DTM+163:202310060815?+00:303'
DTM+164:202310060830?+00:303'
QTY+220:1.962'
DTM+163:202310060830?+00:303'
DTM+164:202310060845?+00:303'
QTY+220:3.6'
DTM+163:202310060845?+00:303'
DTM+164:202310060900?+00:303'
QTY+220:6.162'
DTM+163:202310060900?+00:303'
DTM+164:202310060915?+00:303'
QTY+220:7.05'
DTM+163:202310060915?+00:303'
DTM+164:202310060930?+00:303'
QTY+220:5.062'
DTM+163:202310060930?+00:303'
DTM+164:202310060945?+00:303'
QTY+220:6.262'
DTM+163:202310060945?+00:303'
DTM+164:202310061000?+00:303'
QTY+220:2.275'
DTM+163:202310061000?+00:303'
DTM+164:202310061015?+00:303'
QTY+220:2.912'
DTM+163:202310061015?+00:303'
DTM+164:202310061030?+00:303'
QTY+220:1.525'
DTM+163:202310061030?+00:303'
DTM+164:202310061045?+00:303'
QTY+220:4.262'
DTM+163:202310061045?+00:303'
DTM+164:202310061100?+00:303'
QTY+220:2.712'
DTM+163:202310061100?+00:303'
DTM+164:202310061115?+00:303'
QTY+220:2.962'
DTM+163:202310061115?+00:303'
DTM+164:202310061130?+00:303'
QTY+220:2.438'
DTM+163:202310061130?+00:303'
DTM+164:202310061145?+00:303'
QTY+220:3.338'
DTM+163:202310061145?+00:303'
DTM+164:202310061200?+00:303'
QTY+220:1.938'
DTM+163:202310061200?+00:303'
DTM+164:202310061215?+00:303'
QTY+220:1.125'
DTM+163:202310061215?+00:303'
DTM+164:202310061230?+00:303'
QTY+220:1.1'
DTM+163:202310061230?+00:303'
DTM+164:202310061245?+00:303'
QTY+220:1.038'
DTM+163:202310061245?+00:303'
DTM+164:202310061300?+00:303'
QTY+220:1.062'
DTM+163:202310061300?+00:303'
DTM+164:202310061315?+00:303'
QTY+220:1.262'
DTM+163:202310061315?+00:303'
DTM+164:202310061330?+00:303'
QTY+220:1.1'
DTM+163:202310061330?+00:303'
DTM+164:202310061345?+00:303'
QTY+220:1.25'
DTM+163:202310061345?+00:303'
DTM+164:202310061400?+00:303'
QTY+220:3.038'
DTM+163:202310061400?+00:303'
DTM+164:202310061415?+00:303'
QTY+220:1.062'
DTM+163:202310061415?+00:303'
DTM+164:202310061430?+00:303'
QTY+220:0.675'
DTM+163:202310061430?+00:303'
DTM+164:202310061445?+00:303'
QTY+220:0.562'
DTM+163:202310061445?+00:303'
DTM+164:202310061500?+00:303'
QTY+220:0.575'
DTM+163:202310061500?+00:303'
DTM+164:202310061515?+00:303'
QTY+220:0.525'
DTM+163:202310061515?+00:303'
DTM+164:202310061530?+00:303'
QTY+220:0.588'
DTM+163:202310061530?+00:303'
DTM+164:202310061545?+00:303'
QTY+220:0.562'
DTM+163:202310061545?+00:303'
DTM+164:202310061600?+00:303'
QTY+220:0.575'
DTM+163:202310061600?+00:303'
DTM+164:202310061615?+00:303'
QTY+220:0.55'
DTM+163:202310061615?+00:303'
DTM+164:202310061630?+00:303'
QTY+220:0.562'
DTM+163:202310061630?+00:303'
DTM+164:202310061645?+00:303'
QTY+220:0.7'
DTM+163:202310061645?+00:303'
DTM+164:202310061700?+00:303'
QTY+220:0.662'
DTM+163:202310061700?+00:303'
DTM+164:202310061715?+00:303'
QTY+220:0.7'
DTM+163:202310061715?+00:303'
DTM+164:202310061730?+00:303'
QTY+220:0.662'
DTM+163:202310061730?+00:303'
DTM+164:202310061745?+00:303'
QTY+220:0.712'
DTM+163:202310061745?+00:303'
DTM+164:202310061800?+00:303'
QTY+220:0.662'
DTM+163:202310061800?+00:303'
DTM+164:202310061815?+00:303'
QTY+220:0.712'
DTM+163:202310061815?+00:303'
DTM+164:202310061830?+00:303'
QTY+220:0.688'
DTM+163:202310061830?+00:303'
DTM+164:202310061845?+00:303'
QTY+220:0.7'
DTM+163:202310061845?+00:303'
DTM+164:202310061900?+00:303'
QTY+220:0.662'
DTM+163:202310061900?+00:303'
DTM+164:202310061915?+00:303'
QTY+220:0.7'
DTM+163:202310061915?+00:303'
DTM+164:202310061930?+00:303'
QTY+220:0.725'
DTM+163:202310061930?+00:303'
DTM+164:202310061945?+00:303'
QTY+220:0.675'
DTM+163:202310061945?+00:303'
DTM+164:202310062000?+00:303'
QTY+220:0.662'
DTM+163:202310062000?+00:303'
DTM+164:202310062015?+00:303'
QTY+220:0.662'
DTM+163:202310062015?+00:303'
DTM+164:202310062030?+00:303'
QTY+220:0.7'
DTM+163:202310062030?+00:303'
DTM+164:202310062045?+00:303'
QTY+220:0.688'
DTM+163:202310062045?+00:303'
DTM+164:202310062100?+00:303'
QTY+220:0.7'
DTM+163:202310062100?+00:303'
DTM+164:202310062115?+00:303'
QTY+220:0.638'
DTM+163:202310062115?+00:303'
DTM+164:202310062130?+00:303'
QTY+220:0.788'
DTM+163:202310062130?+00:303'
DTM+164:202310062145?+00:303'
QTY+220:0.638'
DTM+163:202310062145?+00:303'
DTM+164:202310062200?+00:303'
UNT+592+1'
UNZ+1+K21E0D864ED9'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"ENERGIEMENGE": [1 item
{7 fields
"energieverbrauch": [192 items
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
"transaktionsdaten": {11 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ÜNB.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Load curve market location, tranche |
| AHB | MSCONS AHB |
| Transmission channel | MP |
This check identifier is used in 7 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.3 No. 5 | NB → RB HKN-R | Response to meter reading values subscription |
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.4 Case 2 No. 4 | NB → RB HKN-R | Response to meter reading values subscription |
| GPKE part 4 | Business data request | MSB → LF | Response |
| WiM electricity part 2 | Processing and transmission of values from the MSB of the market location | MSB (corresponds to the MSB on the object market location) → NB | Value (market location / metering location) at NB |
| WiM electricity part 2 | Processing and transmission of values from the MSB of the market location | MSB (corresponds to the MSB on the object market location) → LF | Value (market location / metering location) at LF |
| WiM electricity part 2 | Processing and transmission of values from the MSB of the market location | MSB (corresponds to the MSB on the object market location) → ÜNB | Value (market location) at ÜNB |
| GPKE part 4 | Business data request | MSB → NB | Response |
Transaction and responses
Role of this check identifier: response. Basis: the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 17102 | Request for values | ORDERS | from the step sequence |
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfrageReferenz | SG1.RFF+AGI | dokumentennummer |
RFF+AGI quotes the BGM of the request; the target is its dokumentennummer. Measured: 17102 carries dokumentennummer in BGM+[7|Z28|Z48].
Check identifiers of the same AHB table: No other check identifier of message type MSCONS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 145 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type mscons. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.