Check identifier 13002 — Meter reading (Gas)
Check identifier 13002 · EDIFACT message type MSCONS · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 13002 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| ENERGIEMENGE [ ] * | — | object[] | Must | — |
| konfiguration 00010 | konfiguration | string | X | — |
| lokationsId * 00020 | Unique number of the market location or of the metering location to which the energy quantity belongs | string | X | — |
| referenzStammdatenmeldungMsb 00030 | referenzStammdatenmeldungMsb | string | X | — |
| energieverbrauch [ ] * | — | object[] | Must | — |
| ablesedatum 00040 | ablesedatum | string (date-time) | X | — |
| ausfuehrungszeitpunkt 00050 | ausfuehrungszeitpunkt | string (date-time) | X | — |
| enddatum 00060 | enddatum | string (date-time) | X | — |
| messwertstatus * 00070 | The status of a meter reading | Enum Messwertstatus | Must | — |
ABGELESEN | — | — | Must | — |
ERSATZWERT | — | — | Must | — |
VORSCHLAGSWERT | — | — | Must | — |
NICHT_VERWENDBAR | — | — | Must | — |
PROGNOSEWERT | — | — | Must | — |
ENERGIEMENGESUMMIERT | — | — | Must | — |
VOLAEUFIGERWERT | — | — | Must | — |
FEHLT | — | — | Must | — |
ANGABE_FUER_LIEFERSCHEIN | — | — | Must | — |
GRUNDLAGE_POG_ERMITTLUNG | — | — | Must | — |
| nutzungszeitpunkt 00080 | nutzungszeitpunkt | string (date-time) | X | — |
| obiskennzahl * 00090 | obiskennzahl | string | X | — |
| position * 00100 | position | integer | Must | — |
| startdatum 00110 | startdatum | string (date-time) | X | — |
| wert * 00120 | wert | number (float) | Must | — |
| statuszusatzinformationen [ ] | — | object[] | May | — |
| art 00130 | Status type | Enum StatusArt | X | — |
PLAUSIBILISIERUNGSHINWEIS | — | — | X | — |
ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
KORREKTURGRUND | — | — | X | — |
GRUND_ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
GASQUALITAET | — | — | X | — |
MESSKLASSIFIZIERUNG | — | — | X | — |
| status 00140 | Status | Enum Status | X | — |
KUNDENSELBSTABLESUNG | — | — | X | — |
LEERSTAND | — | — | X | — |
REALER_ZAEHLERUEBERLAUF_GEPRUEFT | — | — | X | — |
PLAUSIBEL_WG_KONTROLLABLESUNG | — | — | X | — |
PLAUSIBEL_WG_KUNDENHINWEIS | — | — | X | — |
AUSTAUSCH_DES_ERSATZWERTES | — | — | X | — |
RECHENWERT | — | — | X | — |
BASIS_MME | — | — | X | — |
VERGLEICHSMESSUNG_GEEICHT | — | — | X | — |
VERGLEICHSMESSUNG_NICHT_GEEICHT | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_GEEICHTEN_WERTEN | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_NICHT_GEEICHTEN_WERTEN | — | — | X | — |
INTERPOLATION | — | — | X | — |
HALTEWERT | — | — | X | — |
BILANZIERUNG_NETZABSCHNITT | — | — | X | — |
HISTORISCHE_MESSWERTE | — | — | X | — |
STATISTISCHE_METHODE | — | — | X | — |
AUFTEILUNG | — | — | X | — |
VERWENDUNG_VON_WERTEN_DES_STOERMENGENZAEHLWERKS | — | — | X | — |
UMGANGS_UND_KORREKTURMENGEN | — | — | X | — |
ANGABEN_MESSLOKATION | — | — | X | — |
KEIN_ZUGANG | — | — | X | — |
KOMMUNIKATIONSSTOERUNG | — | — | X | — |
NETZAUSFALL | — | — | X | — |
SPANNUNGSAUSFALL | — | — | X | — |
STATUS_GERAETEWECHSEL | — | — | X | — |
KALIBRIERUNG | — | — | X | — |
GERAET_ARBEITET_AUSSERHALB_DER_BETRIEBSBEDINGUNGEN | — | — | X | — |
MESSEINRICHTUNG_GESTOERT_DEFEKT | — | — | X | — |
UNSICHERHEIT_MESSUNG | — | — | X | — |
BERUECKSICHTIGUNG_STOERMENGENZAEHLWERK | — | — | X | — |
MENGENUMWERTUNG_VOLLSTAENDIG | — | — | X | — |
UHRZEIT_GESTELLT_SYNCHRONISATION | — | — | X | — |
MESSWERT_UNPLAUSIBEL | — | — | X | — |
FALSCHER_WANDLERFAKTOR | — | — | X | — |
FEHLERHAFTE_ABLESUNG | — | — | X | — |
AENDERUNG_DER_BERECHNUNG | — | — | X | — |
UMBAU_DER_MESSLOKATION | — | — | X | — |
DATENBEARBEITUNGSFEHLER | — | — | X | — |
BRENNWERTKORREKTUR | — | — | X | — |
Z_ZAHL_KORREKTUR | — | — | X | — |
STOERUNG_DEFEKT_MESSEINRICHTUNG | — | — | X | — |
AENDERUNG_TARIFSCHALTZEITEN | — | — | X | — |
TARIFSCHALTGERAET_DEFEKT | — | — | X | — |
IMPULSWERTIGKEIT_NICHT_AUSREICHEND | — | — | X | — |
ENERGIEMENGE_IN_UNGEMESSENEM_ZEITINTERVALL | — | — | X | — |
ENERGIEMENGE_AUS_DEM_UNGEPAIRTEN_ZEITINTERVALL | — | — | X | — |
WARTUNGSARBEITEN_AN_GEEICHTEM_MESSGERAET | — | — | X | — |
GESTOERTE_WERTE | — | — | X | — |
WARTUNGSARBEITEN_AN_EICHRECHTSKONFORMEN_MESSGERAETEN | — | — | X | — |
KONSISTENZ_UND_SYNCHRONPRUEFUNG | — | — | X | — |
GRUND_ANGABEN_MESSLOKATION | — | — | X | — |
ANFORDERUNG_IN_DIE_VERGANGENHEIT_ZUM_ANGEFORDERTEN_ZEITPUNKT_LIEGT_KEIN_WERT_VOR | — | — | X | — |
UMSTELLUNG_GASQUALITAET | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
GESCHEITERT | — | — | X | — |
AUSGEBAUT | — | — | X | — |
| ZAEHLER [ ] * | — | object[] | Must | — |
| zaehlernummer * 00150 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| transaktionsdaten * | — | object | Must | — |
| anfrageReferenz 00160 | Application number / RFF+AGI | string | X | — |
| dokumentennummer * 00170 | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| kategorie * 00180 | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| nachrichtendatum * 00190 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenfunktion * 00200 | Message function code / BGM | string | Must | — |
| nachrichtenreferenznummer * 00210 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00220 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00230 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00240 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00250 | Email address | string | Must | — |
| nachname 00260 | Surname (family name) of the contact person | string | X | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00270 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00280 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00290 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00300 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 13002 | Condition |
|---|---|---|---|---|
| UNB | — | — | Must | — |
0001 UNOC00010 | UN/ECE character set C | — | X | — |
0002 300020 | Version 3 | — | X | — |
000400030 | MP-ID Sender | — | X | — |
0007 1400040 | GS1 | — | X | — |
0007 50200050 | DE, DVGW Service & Consult GmbH | — | X | — |
001000060 | MP-ID recipient | — | X | — |
0007 1400070 | GS1 | — | X | — |
0007 50200080 | DE, DVGW Service & Consult GmbH | — | X | — |
001700090 | Date of creation | — | X | — |
001900100 | Time of creation | — | X | — |
002000110 | Interchange control reference | — | X | [918] |
0026 VL00120 | Settlement list, meter reading | — | X | — |
| UNH | — | — | Must | — |
006200130 | Message reference number | — | X | — |
0065 MSCONS00140 | Report on the consumption of measurable services | — | X | — |
0052 D00150 | Draft version | — | X | — |
0054 04B00160 | Edition 2004 - B | — | X | — |
0051 UN00170 | UN/CEFACT | — | X | — |
0057 2.4c00180 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 700190 | Process data report | — | X | — |
100400200 | Document number | — | X | — |
1225 900210 | Original | — | X | — |
| DTM | — | — | Must | — |
2005 13700220 | Document-/message date/time | — | X | — |
238000230 | Date or time or time span, value | — | X | [931] [494] |
2379 30300240 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 AGI00250 | Application number | — | X | — |
115400260 | Reference number | — | X | [529] |
| SG1.RFF | — | — | Must | — |
1153 Z3000270 | Reference to previous master data notification of the MSB | — | X | — |
115400280 | Reference, identification | — | X | [530] |
| SG1.RFF | — | — | Must | — |
1153 Z1300290 | Check identifier | — | X | — |
1154 1300200300 | Meas. val. meter reading (gas) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00310 | Document-/message sender or sender | — | X | — |
303900320 | MP-ID | — | X | [118] |
3055 900330 | GS1 | — | X | — |
3055 33200340 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG4.CTA | — | — | Must | — |
3139 IC00350 | Information point | — | X | — |
341200360 | Department or contact person | — | X | — |
| SG4.COM | — | — | Must | — |
314800370 | Communication address, identification | — | X | (([939] [142]) ∨ ([940] [143])) ∧ [576] |
3155 TE00380 | Telephone | — | X | [1P0..1] |
3155 EM00390 | — | X | [1P0..1] | |
3155 AJ00400 | further telephone | — | X | [1P0..1] |
3155 AL00410 | Mobile phone | — | X | [1P0..1] |
3155 FX00420 | Fax number | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00430 | Message recipient | — | X | — |
303900440 | MP-ID | — | X | [118] |
3055 900450 | GS1 | — | X | — |
3055 33200460 | DE, DVGW Service & Consult GmbH | — | X | — |
| UNS | — | — | Must | — |
0081 D00470 | Separation of header and detail section | — | X | — |
| SG5.NAD | — | — | Must | — |
3035 DP00480 | Supply address | — | X | — |
| SG6.LOC | — | — | Must | — |
3227 17200490 | Reporting point | — | X | — |
322500500 | Designation | — | X | [951] [510] |
| SG7.RFF | — | — | Must | — |
1153 MG00510 | Device number | — | X | — |
115400520 | Device number | — | X | — |
| SG9.LIN | — | — | Must | — |
108200530 | Line item number | — | X | [908] |
| SG9.PIA | — | — | Must | — |
4347 500540 | Product identification | — | X | — |
714000550 | Medium / OBIS code number | — | X | [501] |
7143 SRW00560 | OBIS code | — | X | — |
| SG10.QTY | — | — | Must | — |
6063 22000570 | True value | — | X | — |
6063 6700580 | Substitute value | — | X | [32] |
6063 20100590 | Proposed value | — | X | [35] ∧ [36] ∧ [12] |
6063 2000600 | Unusable value | — | X | [35] ∧ [36] ∧ [12] |
6063 Z1800610 | Preliminary value | — | X | [32] ∧ [12] |
606000620 | Quantity | — | X | ([902] ∧ [906]) ∨ ([902] ∧ [907] [48]) |
| SG10.DTM | — | — | Must | [11] |
2005 16300630 | Processing, start date/time | — | X | — |
238000640 | Date or time or time span, value | — | X | [UB2] |
2379 30300650 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | [11] |
2005 16400660 | Processing, end date/time | — | X | — |
238000670 | Date or time or time span, value | — | X | [UB2] |
2379 30300680 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Should | [12] ∧ [93] ∧ [128] |
2005 900690 | Handling/processing date/time | — | X | — |
238000700 | Date or time or time span, value | — | X | ([931] [111] ∧ [495]) ⊻ ([134] ∧ [135]) |
2379 10200710 | CCYYMMDD | — | X | — |
2379 30300720 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | [12] |
2005 700730 | Effective date/time | — | X | — |
238000740 | Date or time or time span, value | — | X | [UB2] ∧ [495] ∧ ([130] ∨ [133]) |
2379 30300750 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Should | [12] ∧ [129] |
2005 6000760 | Design change date | — | X | — |
238000770 | Date or time or time span, value | — | X | [931] [495] |
2379 30300780 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.STS | — | — | Should | ([92] ⊻ [93] ⊻ [94]) ∧ [126] |
9015 Z3300790 | Plausibility check note | — | X | — |
9013 Z8300800 | Customer self-reading | — | X | [5P0..1] |
9013 Z8400810 | Vacancy | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 Z8500820 | Actual meter overflow checked | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 Z8600830 | Plausible due to check reading | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 Z8700840 | Plausible due to customer information | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 ZC300850 | Exchange of the substitute value | — | X | [5P0..1] |
9013 ZR500860 | Calculated value | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
| SG10.STS | — | — | Must | [92] ⊻ [94] |
9015 Z3200870 | Substitute value formation procedure | — | X | — |
9013 Z8900880 | Comparative measurement (not calibrated) | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9000890 | Meter reading value simulation from calibrated values | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9100900 | Meter reading value simulation from non-calibrated values | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9200910 | Interpolation | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9300920 | Hold value | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9400930 | Balancing grid section | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9500940 | Historical meter reading values | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZQ800950 | Distribution | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZQ900960 | Use of values from the fault quantity register | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZR000970 | Bypass and correction quantities | — | X | [4P0..1] ⊻ [6P0..1] |
| SG10.STS | — | — | Should | [127] ∧ [559] |
9015 Z3400980 | Reason for correction | — | X | — |
9013 Z7400990 | no access | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z7501000 | Communication fault | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z7601010 | Grid outage | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z7801020 | Device replacement | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z8001030 | Device operates outside the operating conditions | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z8101040 | Measuring equipment faulty/defective | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z8201050 | Measurement uncertainty | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z9801060 | Consideration of the fault quantity register | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9901070 | Volume conversion incomplete | — | X | [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA001080 | Time set /synchronisation | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA101090 | Meter reading value implausible | — | X | [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA401100 | Incorrect reading | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA501110 | Change of the calculation | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA601120 | Conversion of the metering location | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA701130 | Data processing error | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA801140 | Calorific value correction | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA901150 | Z-number correction | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZB001160 | Fault / defect of measuring equipment | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZC401170 | Pulse value not sufficient | — | X | [4P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR101180 | Maintenance work on a calibrated measuring device | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR201190 | faulty values | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR301200 | Maintenance work on measuring devices compliant with calibration law | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR401210 | Consistency and synchronisation check | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
| SG10.STS | — | — | Must | [92] |
9015 Z4001220 | Reason for substitute value formation | — | X | — |
9013 Z7401230 | no access | — | X | [4P0..1] |
9013 Z7501240 | Communication fault | — | X | [4P0..1] |
9013 Z7601250 | Grid outage | — | X | [4P0..1] |
9013 Z7801260 | Device replacement | — | X | [4P0..1] |
9013 Z8001270 | Device operates outside the operating conditions | — | X | [4P0..1] |
9013 Z8101280 | Measuring equipment faulty/defective | — | X | [4P0..1] |
9013 Z8201290 | Measurement uncertainty | — | X | [4P0..1] |
9013 Z9801300 | Consideration of the fault quantity register | — | X | [4P0..1] |
9013 Z9901310 | Volume conversion incomplete | — | X | [4P0..1] |
9013 ZA001320 | Time set /synchronisation | — | X | [4P0..1] |
9013 ZA101330 | Meter reading value implausible | — | X | [4P0..1] |
9013 ZA401340 | Incorrect reading | — | X | [4P0..1] |
9013 ZA501350 | Change of the calculation | — | X | [4P0..1] |
9013 ZA601360 | Conversion of the metering location | — | X | [4P0..1] |
9013 ZA701370 | Data processing error | — | X | [4P0..1] |
9013 ZB001380 | Fault / defect of measuring equipment | — | X | [4P0..1] |
9013 ZC401390 | Pulse value not sufficient | — | X | [4P0..1] |
9013 ZR101400 | Maintenance work on a calibrated measuring device | — | X | [4P0..1] |
9013 ZR201410 | faulty values | — | X | [4P0..1] |
9013 ZR301420 | Maintenance work on measuring devices compliant with calibration law | — | X | [4P0..1] |
9013 ZR401430 | Consistency and synchronisation check | — | X | [4P0..1] |
9013 ZT801440 | Request into the past; no value is available for the requested point in time. | — | X | [4P0..1] |
| SG10.STS | — | — | Should | [97] |
9015 Z3101450 | Gas quality | — | X | — |
9013 ZG301460 | Change of gas quality | — | X | — |
| UNT | — | — | Must | — |
007401470 | Number of segments in a message | — | X | — |
006201480 | Message reference number | — | X | — |
| UNZ | — | — | Must | — |
003601490 | Interchange counter | — | X | — |
002001500 | Interchange control reference | — | X | — |
Conditions of this table
The free text of the 46 conditions referenced by the rows above. All conditions of the message type are listed in the condition index MSCONS.
| Marker | Condition |
|---|---|
| [11] | If SG9 PIA+5+7-0?:52.0.22/7-0?:54.0.16/7-0?:54.0.20/7-0?:54.0.22 |
| [12] | If not SG9 PIA+5+7-0?:52.0.22/7-0?:54.0.16/7-0?:54.0.20/7-0?:54.0.22 |
| [32] | if MP-ID in SG2 NAD+MS in the role NB |
| [35] | if MP-ID in SG2 NAD+MS in the role MSB |
| [36] | if MP-ID in SG2 NAD+MR in the role NB |
| [48] | If SG9 PIA+5+7-0?:52.0.22 |
| [92] | If SG10 QTY DE6063 with value 67 is present |
| [93] | If SG10 QTY DE6063 with value 220 is present |
| [94] | If SG10 QTY DE6063 with value 201 is present |
| [97] | If this concerns the transmission of a value due to the change of the gas quality |
| [111] | If SG10 DTM+9 DE2379 with value 303 is present in the same segment |
| [118] | Only MP-ID from the gas division |
| [126] | if plausibility check notices exist |
| [127] | if a correction reason has to be stated |
| [128] | If this concerns a meter reading which is not a reading due to a change to the metering equipment or its configuration (e.g. customer reading). |
| [129] | If this concerns a meter reading due to a change to the metering equipment or its configuration (e.g. device replacement). |
| [130] | If, within the same LIN segment and in addition to this segment (SG10 DTM+7 usage point in time), the SG10 DTM+60 (execution / change point in time) or the SG10 DTM+9 (reading date) is also present, the value of the difference between the later and the earlier point in time of the DTM segments may only be < 24 hours. If the summer/winter time changeover takes place between the two points in time, the value of the difference may only be < 25 hours. If the winter/summer time changeover takes place between the two points in time, the value of the difference may only be < 23 hours. |
| [133] | If, within the same LIN segment and in addition to this segment (SG10 DTM+7 usage point in time), the SG10 DTM+9 (reading date) with the code 102 in DE2379 is also present, the value of the difference between the value at position CCYYMMDD of the later and the earlier point in time of the DTM segments at position CCYYMMDD may only be 0 or 1 day. |
| [134] | If SG10 DTM+9 DE2379 with value 102 is present in the same segment |
| [135] | The value at position CCYYMMDD must be ≤ the value at position CCYYMMDD in DE2380 of DTM+137 |
| [142] | if the code EM is present in DE3155 in the same COM |
| [143] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [501] | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| [510] | Note: Use of the ID of the metering location |
| [529] | Note: Value from BGM+7 DE1004 of the ORDERS with which the request for meter reading values was made. |
| [530] | Note: Value from SG4 IDE+24 DE7402 of the UTILMD with which the sender of the MSCONS transmitted the previous master data by means of UTILMD. |
| [559] | Note: A correction reason is to be specified if: 1. a preliminary value already transmitted to the MP is replaced by a substitute value after cancellation, or 2. a substitute value already transmitted to the MP is replaced by a substitute value after cancellation, or 3. a true value already transmitted to the MP is replaced by a substitute value after cancellation, or 4. a true value already transmitted to the MP is replaced by a true value after cancellation. |
| [576] | Note: Only one piece of information may be transmitted in DE3148 |
| [902] | Format: Possible value: ≥ 0 |
| [906] | Format: max. 3 decimal places |
| [907] | Format: max. 4 decimal places |
| [908] | Format: possible values: 1 to n |
| [918] | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [951] | Format: Metering point identifier |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment |
| [UB2] | ([931] ∧ [934] [490]) ⊻ ([931] ∧ [935] [491]) |
| [5P0..1] | [93] If SG10 QTY DE6063 with value 220 present |
| [4P0..1] | [92] If SG10 QTY DE6063 with value 67 present |
| [6P0..1] | [94] If SG10 QTY DE6063 with value 201 present |
| [7P0..1] | [95] If SG10 QTY DE6063 with value 20 present |
| [8P0..1] | [96] If SG10 QTY DE6063 with value Z18 present |
Example message
UNA:+.? '
UNB+UNOC:3+9870013800007:502+9800044300007:502+{{date}}:{{time}}+143823++VL'
UNH+343364+MSCONS:D:04B:UN:2.4c'
BGM+7+343364BGM+9'
DTM+137:202307310922?+00:303'
RFF+AGI:12345678910'
RFF+Z30:UTILMDXYZ_1235'
RFF+Z13:13002'
NAD+MS+9870013800007::332'
CTA+IC+:Max Mustermann'
COM+?+012345678910:TE'
NAD+MR+9800044300007::332'
UNS+D'
NAD+DP'
LOC+172+DE0032106765712000000000000000041'
RFF+MG:1234567'
LIN+1'
PIA+5+7-0?:3.0.0:SRW'
QTY+220:1234.123'
DTM+9:202307310400?+00:303'
DTM+7:202307310400?+00:303'
UNT+20+343364'
UNZ+1+143823'[1 item
{6 fields
"data": {3 fields
"stammdaten": {2 fields
"ZAEHLER": [1 item
{4 fields
"ENERGIEMENGE": [1 item
{6 fields
"energieverbrauch": [1 item
{6 fields
"transaktionsdaten": {12 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"rufnummern": [1 item
{2 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Meter reading (gas) |
| AHB | MSCONS AHB |
| Response to check identifier | 17102 |
| Transmission channel | AS4 |
This check identifier is used in 29 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM gas | Ch. B 5.1.3 No. 7 | MSBN → NB | Transmission of final reading values by MSBN or MSBA |
| WiM gas | Ch. B 5.1.3 No. 7 | MSBA → NB | Transmission of final reading values by MSBN or MSBA |
| WiM gas | Ch. B 5.1.3 No. 8 | MSBN → NB | Notification of device replacement, master data and installation meter reading |
| Guideline on market processes for grid operator change | Value transmission Gas to NB | NBA → NBN | Values metering location |
| GeLi Gas 2.0 | GeLi_Gas 2.0 ch. 4.1.1.1 Collection of measured values | LF → NB | — |
| GeLi Gas 2.0 | Request and provision of meter reading values | MSB → NB | Meter reading transmission |
| GeLi Gas 2.0 | Request and provision of meter reading values | NB → MSB | Transmission of substitute values |
| GeLi Gas 2.0 | Request and provision of meter reading values | NB → LF | Meter reading transmission |
| GeLi Gas 2.0 | Periodic/regular meter reading transmission | MSB → NB | Meter reading date for measuring equipment with balancing based on profiles |
| GeLi Gas 2.0 | Periodic/regular meter reading transmission | MSB → NB | Regular reading of measuring equipment with RLM |
| GeLi Gas 2.0 | Off-cycle meter reading transmission | MSB → NB | Start of supply/ start of substitute/ basic supply |
| GeLi Gas 2.0 | Off-cycle meter reading transmission | MSB → NB | End of supply / deregistration request |
| GeLi Gas 2.0 | Off-cycle meter reading transmission | MSB → NB | Interim meter reading |
| GeLi Gas 2.0 | Off-cycle meter reading transmission | MSB → NB | Device replacement or change of configuration for measuring equipment connected to a SMGW (electricity)) |
| GeLi Gas 2.0 | Business data request from LF to NB | NB → LF | Response |
| GeLi Gas 2.0 | Billing of grid usage | NB → LF | ongoing meter reading values |
| AWH WiM gas 2.0 | Device replacement | MSBN → MSBA | Meter reading and point in time of the device removal |
| AWH WiM gas 2.0 | Transmission of values from LF to NB | LF → NB | Values |
| AWH WiM gas 2.0 | Transmission of values from MSB to NB | MSB → NB | Values |
| GeLi Gas | Ch. D 1.1.1 | LF → NB | — |
| GeLi Gas | Ch. D 1.2.4 No. 11 | NB → LF | Meter reading transmission |
| GeLi Gas | Ch. D 1.2.4 No. 7 | MSB → NB | Meter reading transmission |
| GeLi Gas | Ch. D 1.2.4 No. 9 | NB → MSB | Transmission of substitute values |
| GeLi Gas | Ch. D 2.2 No. 2 | NB → LF | Response |
| GeLi Gas | Ch. D 2.3 No. 2 | NB → MSB | Response |
| GeLi Gas | Ch. D 3.2 No. 2 | NB → LF | Response |
| WiM gas | UF GeLiGas_006 business data request from NB to MSB | MSB → NB | Response |
| GeLi Gas | Ch. D 1.2.3 No. 7 | MSB → NB | Meter reading transmission |
| GeLi Gas | Ch. D 1.2.3 No. 9 | NB → MSB | Transmission of substitute values |
Further relationships from format version 202610
Version 202610 also carries this check identifier in contexts that the table of version 202604 does not know; they are included in the list above. Everything else on this page — use case, rulebook and communication direction — comes from the page's own version. Before adopting it into an implementation specification, check whether what is stated applies to 202604.
Transaction and responses
Role of this check identifier: response. Basis: the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 17102 | Request for values | ORDERS | explicit |
Forwarding (triangular communication): The preceding step holds 21010 with the same send direction. This message therefore does not answer the sender of the preceding step, it forwards — which is why there is no response sentence here.
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfrageReferenz | SG1.RFF+AGI | dokumentennummer |
RFF+AGI quotes the BGM of the request; the target is its dokumentennummer. Measured: 17102 carries dokumentennummer in BGM+[7|Z28|Z48].
Check identifiers of the same AHB table: No other check identifier of message type MSCONS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 180 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type mscons. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.