Check identifier 13006 — Meter reading value cancellation
Check identifier 13006 · EDIFACT message type MSCONS · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 13006 | Condition |
|---|---|---|---|---|
| transaktionsdaten * | — | object | Must | — |
| dokumentennummer * 00010 | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| kategorie * 00020 | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| nachrichtendatum * 00030 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenfunktion * 00040 | Message function code / BGM | string | Must | — |
| nachrichtenreferenznummer * 00050 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00060 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| vorgangsreferenznummer * 00070 | Reference number of the transaction of the registration according to WiM / ORDERS RFF+Z41 / IFTSTA RFF+ACW | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00080 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00090 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00100 | Email address | string | Must | — |
| nachname 00110 | Surname (family name) of the contact person | string | X | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00120 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00130 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00140 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00150 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 13006 | Condition |
|---|---|---|---|---|
| UNB | — | — | Must | — |
0001 UNOC00010 | UN/ECE character set C | — | X | — |
0002 300020 | Version 3 | — | X | — |
000400030 | MP-ID Sender | — | X | — |
0007 1400040 | GS1 | — | X | — |
0007 50000050 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
0007 50200060 | DE, DVGW Service & Consult GmbH | — | X | — |
001000070 | MP-ID recipient | — | X | — |
0007 1400080 | GS1 | — | X | — |
0007 50000090 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
0007 50200100 | DE, DVGW Service & Consult GmbH | — | X | — |
001700110 | Date of creation | — | X | — |
001900120 | Time of creation | — | X | — |
002000130 | Interchange control reference | — | X | [918] |
0026 EM00140 | Energy quantity | — | X | — |
0026 VL00150 | Settlement list, meter reading | — | X | — |
| UNH | — | — | Must | — |
006200160 | Message reference number | — | X | — |
0065 MSCONS00170 | Report on the consumption of measurable services | — | X | — |
0052 D00180 | Draft version | — | X | — |
0054 04B00190 | Edition 2004 - B | — | X | — |
0051 UN00200 | UN/CEFACT | — | X | — |
0057 2.4c00210 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 700220 | Process data report | — | X | — |
1001 27000230 | Delivery note | — | X | [547] |
1001 Z2700240 | Transaction data in the calendar year before the start of supply | — | X | — |
1001 Z2800250 | Energy quantity and maximum demand | — | X | — |
1001 Z4100260 | Delivery note base price / energy price | — | X | — |
1001 Z4200270 | Delivery note energy price / demand price | — | X | — |
1001 Z8500280 | Basis for POG determination | — | X | — |
100400290 | Document number | — | X | — |
1225 100300 | Cancellation | — | X | — |
| DTM | — | — | Must | — |
2005 13700310 | Document-/message date/time | — | X | — |
238000320 | Date or time or time span, value | — | X | [931] [494] |
2379 30300330 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 ACW00340 | Reference number of a preceding message | — | X | — |
115400350 | Reference number | — | X | [532] |
| SG1.RFF | — | — | Must | — |
1153 Z1300360 | Check identifier | — | X | — |
1154 1300600370 | Meas. val. cancellation | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00380 | Document-/message sender or sender | — | X | — |
303900390 | MP-ID | — | X | — |
3055 900400 | GS1 | — | X | — |
3055 29300410 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33200420 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG4.CTA | — | — | Must | — |
3139 IC00430 | Information point | — | X | — |
341200440 | Department or contact person | — | X | — |
| SG4.COM | — | — | Must | — |
314800450 | Communication address, identification | — | X | (([939] [142]) ∨ ([940] [143])) ∧ [576] |
3155 TE00460 | Telephone | — | X | [1P0..1] |
3155 EM00470 | — | X | [1P0..1] | |
3155 AJ00480 | further telephone | — | X | [1P0..1] |
3155 AL00490 | Mobile phone | — | X | [1P0..1] |
3155 FX00500 | Fax number | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00510 | Message recipient | — | X | — |
303900520 | MP-ID | — | X | — |
3055 900530 | GS1 | — | X | — |
3055 29300540 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
3055 33200550 | DE, DVGW Service & Consult GmbH | — | X | — |
| UNS | — | — | Must | — |
0081 D00560 | Separation of header and detail section | — | X | — |
| SG5.NAD | — | — | Must | — |
3035 DP00570 | Supply address | — | X | — |
| SG6.LOC | — | — | Must | — |
3227 17200580 | Reporting point | — | X | — |
| UNT | — | — | Must | — |
007400590 | Number of segments in a message | — | X | — |
006200600 | Message reference number | — | X | — |
| UNZ | — | — | Must | — |
003600610 | Interchange counter | — | X | — |
002000620 | Interchange control reference | — | X | — |
Conditions of this table
The free text of the 11 conditions referenced by the rows above. All conditions of the message type are listed in the condition index MSCONS.
| Marker | Condition |
|---|---|
| [142] | if the code EM is present in DE3155 in the same COM |
| [143] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [532] | Note: Value from BGM+7/Z27/Z28/270/Z41/Z42/Z85 DE1004 of the MSCONS message that is being canceled |
| [547] | Note: Code 270 is only to be used if a delivery note created before 1.4.2021 is canceled. |
| [576] | Note: Only one piece of information may be transmitted in DE3148 |
| [918] | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment |
Example message
UNA:+.? '
UNB+UNOC:3+9904446000007:500+9900321000005:500+{{date}}:{{time}}+978509++VL'
UNH+542637+MSCONS:D:04B:UN:2.4c'
BGM+7+542637BGM+1'
DTM+137:202303300908?+00:303'
RFF+ACW:REF123456789'
RFF+Z13:13006'
NAD+MS+9904446000007::293'
CTA+IC+:Max Mustermann'
COM+max@mustermann.de:EM'
COM+?+012345678920:AJ'
COM+?+012345678940:FX'
COM+?+012345678910:TE'
COM+?+012345678930:AL'
NAD+MR+9900321000005::293'
UNS+D'
NAD+DP'
LOC+172'
UNT+17+542637'
UNZ+1+978509'[1 item
{6 fields
"data": {3 fields
"transaktionsdaten": {12 fields
"absender": {5 fields
"ansprechpartner": {5 fields
"rufnummern": [4 items
{2 fields
{2 fields
{2 fields
{2 fields
"empfaenger": {4 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ÜNB.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Meter reading value cancellation |
| AHB | MSCONS AHB |
| Transmission channel | AS4 |
This check identifier is used in 25 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM gas | Ch. B 5.1.3 No. 7 | MSBA → NB | Transmission of final reading values by MSBN or MSBA |
| WiM gas | Ch. B 5.1.3 No. 7 | MSBN → NB | Transmission of final reading values by MSBN or MSBA |
| WiM gas | Ch. B 5.1.3 No. 8 | MSBN → NB | Transmission of final reading values by MSBN or MSBA |
| GPKE part 2 | Transmission of the delivery note for the grid usage settlement | NB → LF | Cancellation of delivery note |
| WiM electricity part 2 | Cancellation of values from the MSB of the metering location | MSB (corresponds to MSB on the object metering location) → MSB (corresponds to MSB on the object market location) | Cancellation |
| WiM electricity part 2 | Cancellation of values from the MSB of the market location | MSB (corresponds to MSB on the object market location) → NB | Cancellation to NB |
| WiM electricity part 2 | Cancellation of values from the MSB of the market location | MSB (corresponds to MSB on the object market location) → LF | Cancellation to LF |
| WiM electricity part 2 | Cancellation of values from the MSB of the market location | MSB (corresponds to MSB on the object market location) → ÜNB | Cancellation to ÜNB |
| WiM electricity part 2 | Cancellation of meter readings from the LF | LF → MSB (metering location) | Cancellation |
| WiM electricity part 2 | Cancellation of meter readings from the NB | NB → MSB (metering location) | Cancellation |
| GeLi Gas 2.0 | Request and provision of meter reading values | MSB → NB | Meter reading transmission |
| GeLi Gas 2.0 | Request and provision of meter reading values | NB → MSB | Transmission of substitute values |
| GeLi Gas 2.0 | Request and provision of meter reading values | NB → LF | Meter reading transmission |
| GeLi Gas 2.0 | Periodic/regular meter reading transmission | MSB → NB | Meter reading date for measuring equipment with balancing based on profiles |
| GeLi Gas 2.0 | Periodic/regular meter reading transmission | MSB → NB | Regular reading of measuring equipment with RLM |
| GeLi Gas 2.0 | Off-cycle meter reading transmission | MSB → NB | Start of supply/ start of substitute/ basic supply |
| GeLi Gas 2.0 | Off-cycle meter reading transmission | MSB → NB | End of supply / deregistration request |
| GeLi Gas 2.0 | Off-cycle meter reading transmission | MSB → NB | Interim meter reading |
| GeLi Gas 2.0 | Off-cycle meter reading transmission | MSB → NB | Device replacement or change of configuration for measuring equipment connected to a SMGW (electricity)) |
| GeLi Gas 2.0 | Billing of grid usage | NB → LF | ongoing meter reading values |
| AWH WiM gas 2.0 | Transmission of values from LF to NB | LF → NB | Values |
| AWH WiM gas 2.0 | Transmission of values from MSB to NB | MSB → NB | Values |
| GeLi Gas | Ch. A 9 | MSB → NB | — |
| GeLi Gas | Ch. A 9 | NB → LF | — |
| GeLi Gas | Ch. A 9 | LF → NB | — |
Further relationships from format version 202610
Version 202610 also carries this check identifier in contexts that the table of version 202604 does not know; they are included in the list above. Everything else on this page — use case, rulebook and communication direction — comes from the page's own version. Before adopting it into an implementation specification, check whether what is stated applies to 202604.
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.
Responses: No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.
Check identifiers of the same AHB table: No other check identifier of message type MSCONS has the same row structure in this version.
Editorial — not derived from a source
Which meter readings this cancellation withdraws. The cancellation cites the withdrawn meter reading message via RFF+ACW (reference number of a previous message), in the JSON transaktionsdaten.vorgangsreferenznummer (SG1.RFF+ACW). You trigger it via the event START_VERSAND_STORNO_MSCONS, which exists for LF, MSB and NB. If the withdrawn message was the response to a request, it in turn cites that request via anfrageReferenz (SG1.RFF+AGI, application number); this is how the meter reading messages 13002, 13008, 13009, 13015 to 13019, 13025 and 13027 carry it. Examples from the test set: RFF+ACW:REF123456789 (13006, test case 1), RFF+AGI:12345678910 (13002, test case 1). The values there are placeholders and do not point to each other.
Source: MSCONS AHB (Knowledge Collection ahb/202604/MSCONS/13006.json and ahb/202610/MSCONS/13006.json, SG1 RFF+ACW); specification PI_13006 (segment mapping of vorgangsreferenznummer); event specifications START_VERSAND_STORNO_MSCONS of the roles LF, MSB and NB; test set maco-edi-testfiles, inbound/v202404/MSCONS: 13006_Testfall1_eingehend.edi and 13002_eingehend_Testfall1.edi · As of: 2026-09-23 · Applies to format version: 202604, 202610 · To be reviewed by: 2027-04-01
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 77 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type mscons. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.