Check identifier 13026 — EEG transfer TS due to curtailed energy
Check identifier 13026 · EDIFACT message type MSCONS · Format version 202604
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 13026 | Condition |
|---|---|---|---|---|
| UNB | — | — | Must | — |
0001 UNOC00010 | UN/ECE character set C | — | X | — |
0002 300020 | Version 3 | — | X | — |
000400030 | MP-ID Sender | — | X | — |
0007 1400040 | GS1 | — | X | — |
0007 50000050 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
001000060 | MP-ID recipient | — | X | — |
0007 1400070 | GS1 | — | X | — |
0007 50000080 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
001700090 | Date of creation | — | X | — |
001900100 | Time of creation | — | X | — |
002000110 | Interchange control reference | — | X | [918] |
0026 TL00120 | Load curve, any time period | — | X | — |
| UNH | — | — | Must | — |
006200130 | Message reference number | — | X | — |
0065 MSCONS00140 | Report on the consumption of measurable services | — | X | — |
0052 D00150 | Draft version | — | X | — |
0054 04B00160 | Edition 2004 - B | — | X | — |
0051 UN00170 | UN/CEFACT | — | X | — |
0057 2.4c00180 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z5000190 | Redispatch EEG transfer time series due to curtailed energy | — | X | — |
100400200 | Document number | — | X | — |
1225 900210 | Original | — | X | — |
| DTM | — | — | Must | — |
2005 13700220 | Document-/message date/time | — | X | — |
238000230 | Date or time or time span, value | — | X | [931] [494] |
2379 30300240 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 Z1300250 | Check identifier | — | X | — |
1154 1302600260 | Redispatch EEG transfer time series due to curtailed energy | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00270 | Document-/message sender or sender | — | X | — |
303900280 | MP-ID | — | X | [117] |
3055 900290 | GS1 | — | X | — |
3055 29300300 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.CTA | — | — | Must | — |
3139 IC00310 | Information point | — | X | — |
341200320 | Department or contact person | — | X | — |
| SG4.COM | — | — | Must | — |
314800330 | Communication address, identification | — | X | (([939] [142]) ∨ ([940] [143])) ∧ [576] |
3155 TE00340 | Telephone | — | X | [1P0..1] |
3155 EM00350 | — | X | [1P0..1] | |
3155 AJ00360 | further telephone | — | X | [1P0..1] |
3155 AL00370 | Mobile phone | — | X | [1P0..1] |
3155 FX00380 | Fax number | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00390 | Message recipient | — | X | — |
303900400 | MP-ID | — | X | [117] |
3055 900410 | GS1 | — | X | — |
3055 29300420 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| UNS | — | — | Must | — |
0081 D00430 | Separation of header and detail section | — | X | — |
| SG5.NAD | — | — | Must | — |
3035 Z1500440 | Transfer time series | — | X | — |
| SG6.LOC | — | — | Must | — |
3227 23700450 | Balancing group | — | X | — |
322500460 | Balancing group to | — | X | [904] [512] |
322300470 | Balancing group from | — | X | [904] [512] |
| SG6.LOC | — | — | Must | — |
3227 10700480 | Balancing area | — | X | — |
322500490 | Designation | — | X | [904] [513] |
| SG6.DTM | — | — | Must | — |
2005 16300500 | Processing, start date/time | — | X | — |
238000510 | Date or time or time span, value | — | X | [931] |
2379 30300520 | CCYYMMDDHHMMZZZ | — | X | — |
| SG6.DTM | — | — | Must | — |
2005 16400530 | Processing, end date/time | — | X | — |
238000540 | Date or time or time span, value | — | X | [931] |
2379 30300550 | CCYYMMDDHHMMZZZ | — | X | — |
| SG6.DTM | — | — | Must | — |
2005 29300560 | Completion date/time | — | X | — |
238000570 | Date or time or time span, value | — | X | — |
2379 30400580 | CCYYMMDDHHMMSSZZZ | — | X | — |
| SG8.CCI | — | — | Must | — |
7059 1500590 | Structure | — | X | — |
703700600 | Time series type | — | X | — |
| SG9.LIN | — | — | Must | — |
108200610 | Line item number | — | X | [908] |
| SG9.PIA | — | — | Must | — |
4347 500620 | Product identification | — | X | — |
714000630 | Medium / OBIS code number | — | X | [501] |
7143 Z0800640 | Medium | — | X | — |
| SG10.QTY | — | — | Must | — |
6063 7900650 | Energy quantity totalled (total value, balance total) | — | X | — |
606000660 | Quantity | — | X | [910] ∧ [906] |
6411 KWH00670 | Kilowatt hour | — | X | — |
| SG10.DTM | — | — | Must | — |
2005 16300680 | Processing, start date/time | — | X | — |
238000690 | Date or time or time span, value | — | X | [931] [495] |
2379 30300700 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | — |
2005 16400710 | Processing, end date/time | — | X | — |
238000720 | Date or time or time span, value | — | X | [931] [495] |
2379 30300730 | CCYYMMDDHHMMZZZ | — | X | — |
| UNT | — | — | Must | — |
007400740 | Number of segments in a message | — | X | — |
006200750 | Message reference number | — | X | — |
| UNZ | — | — | Must | — |
003600760 | Interchange counter | — | X | — |
002000770 | Interchange control reference | — | X | — |
Conditions of this table
The free text of the 18 conditions referenced by the rows above. All conditions of the message type are listed in the condition index MSCONS.
| Marker | Condition |
|---|---|
| [117] | Only MP-ID from the electricity division |
| [142] | if the code EM is present in DE3155 in the same COM |
| [143] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [501] | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| [512] | Note: Use of the balancing group designation |
| [513] | Note: Use of the designation of the balancing area |
| [576] | Note: Only one piece of information may be transmitted in DE3148 |
| [904] | Format: exactly 16 digits |
| [906] | Format: max. 3 decimal places |
| [908] | Format: possible values: 1 to n |
| [910] | Format: Possible value: < 0 or ≥ 0 |
| [918] | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB, BIKO and BKV.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | NB | Forwarding of EEG transfer time series | Business processes for EEG transfer time series V1.0 | Electricity | Step 1 |
| NB | NB | Forwarding of EEG transfer time series | Business processes for EEG transfer time series V1.0 | Electricity | Step 2 |
| NB | NB | Forwarding of EEG transfer time series | Business processes for EEG transfer time series V1.0 | Electricity | Step 3 |
| BIKO | BIKO | Forwarding of EEG transfer time series | Business processes for EEG transfer time series V1.0 | Electricity | Step 1 |
| BIKO | BIKO | Forwarding of EEG transfer time series | Business processes for EEG transfer time series V1.0 | Electricity | Step 2 |
| BIKO | BIKO | Forwarding of EEG transfer time series | Business processes for EEG transfer time series V1.0 | Electricity | Step 3 |
| BKV | BKV-NB | Forwarding of EEG transfer time series | Business processes for EEG transfer time series V1.0 | Electricity | Step 1 |
| BKV | BKV-NB | Forwarding of EEG transfer time series | Business processes for EEG transfer time series V1.0 | Electricity | Step 2 |
| BKV | BKV-NB | Forwarding of EEG transfer time series | Business processes for EEG transfer time series V1.0 | Electricity | Step 3 |
| BKV | BKV-UENB | Forwarding of EEG transfer time series | Business processes for EEG transfer time series V1.0 | Electricity | Step 1 |
| BKV | BKV-UENB | Forwarding of EEG transfer time series | Business processes for EEG transfer time series V1.0 | Electricity | Step 2 |
| BKV | BKV-UENB | Forwarding of EEG transfer time series | Business processes for EEG transfer time series V1.0 | Electricity | Step 3 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | EEG transf. TS due to curtailed energy |
| AHB | MSCONS AHB |
| Transmission channel | AS4 |
This check identifier is used in 3 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| Business processes for EEG transfer time series V1.0 | Forwarding of EEG transfer time series | BIKO → BKV (NB) | Forwarding of transfer time series |
| Business processes for EEG transfer time series V1.0 | Forwarding of EEG transfer time series | BIKO → BKV (ÜNB) | Forwarding of transfer time series |
| Business processes for EEG transfer time series V1.0 | Forwarding of EEG transfer time series | BIKO → NB | Information on transfer time series |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 101 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.