Check identifier 13002 — Meter reading (Gas)
Check identifier 13002 · EDIFACT message type MSCONS · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 13002 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| ENERGIEMENGE [ ] * | — | object[] | Must | — |
| konfiguration 00010 | konfiguration | string | X | — |
| lokationsId * 00020 | Unique number of the market location or of the metering location to which the energy quantity belongs | string | X | — |
| referenzStammdatenmeldungMsb 00030 | referenzStammdatenmeldungMsb | string | X | — |
| energieverbrauch [ ] * | — | object[] | Must | — |
| ablesedatum 00040 | ablesedatum | string (date-time) | X | — |
| ausfuehrungszeitpunkt 00050 | ausfuehrungszeitpunkt | string (date-time) | X | — |
| enddatum 00060 | enddatum | string (date-time) | X | — |
| messwertstatus * 00070 | The status of a meter reading | Enum Messwertstatus | Must | — |
ABGELESEN | — | — | Must | — |
ERSATZWERT | — | — | Must | — |
VORSCHLAGSWERT | — | — | Must | — |
NICHT_VERWENDBAR | — | — | Must | — |
PROGNOSEWERT | — | — | Must | — |
ENERGIEMENGESUMMIERT | — | — | Must | — |
VOLAEUFIGERWERT | — | — | Must | — |
FEHLT | — | — | Must | — |
ANGABE_FUER_LIEFERSCHEIN | — | — | Must | — |
GRUNDLAGE_POG_ERMITTLUNG | — | — | Must | — |
| nutzungszeitpunkt 00080 | nutzungszeitpunkt | string (date-time) | X | — |
| obiskennzahl * 00090 | obiskennzahl | string | X | — |
| position * 00100 | position | integer | Must | — |
| startdatum 00110 | startdatum | string (date-time) | X | — |
| wert * 00120 | wert | number (float) | Must | — |
| statuszusatzinformationen [ ] | — | object[] | May | — |
| art 00130 | Status type | Enum StatusArt | X | — |
PLAUSIBILISIERUNGSHINWEIS | — | — | X | — |
ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
KORREKTURGRUND | — | — | X | — |
GRUND_ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
GASQUALITAET | — | — | X | — |
MESSKLASSIFIZIERUNG | — | — | X | — |
| status 00140 | Status | Enum Status | X | — |
KUNDENSELBSTABLESUNG | — | — | X | — |
LEERSTAND | — | — | X | — |
REALER_ZAEHLERUEBERLAUF_GEPRUEFT | — | — | X | — |
PLAUSIBEL_WG_KONTROLLABLESUNG | — | — | X | — |
PLAUSIBEL_WG_KUNDENHINWEIS | — | — | X | — |
AUSTAUSCH_DES_ERSATZWERTES | — | — | X | — |
RECHENWERT | — | — | X | — |
BASIS_MME | — | — | X | — |
VERGLEICHSMESSUNG_GEEICHT | — | — | X | — |
VERGLEICHSMESSUNG_NICHT_GEEICHT | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_GEEICHTEN_WERTEN | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_NICHT_GEEICHTEN_WERTEN | — | — | X | — |
INTERPOLATION | — | — | X | — |
HALTEWERT | — | — | X | — |
BILANZIERUNG_NETZABSCHNITT | — | — | X | — |
HISTORISCHE_MESSWERTE | — | — | X | — |
STATISTISCHE_METHODE | — | — | X | — |
AUFTEILUNG | — | — | X | — |
VERWENDUNG_VON_WERTEN_DES_STOERMENGENZAEHLWERKS | — | — | X | — |
UMGANGS_UND_KORREKTURMENGEN | — | — | X | — |
ANGABEN_MESSLOKATION | — | — | X | — |
KEIN_ZUGANG | — | — | X | — |
KOMMUNIKATIONSSTOERUNG | — | — | X | — |
NETZAUSFALL | — | — | X | — |
SPANNUNGSAUSFALL | — | — | X | — |
STATUS_GERAETEWECHSEL | — | — | X | — |
KALIBRIERUNG | — | — | X | — |
GERAET_ARBEITET_AUSSERHALB_DER_BETRIEBSBEDINGUNGEN | — | — | X | — |
MESSEINRICHTUNG_GESTOERT_DEFEKT | — | — | X | — |
UNSICHERHEIT_MESSUNG | — | — | X | — |
BERUECKSICHTIGUNG_STOERMENGENZAEHLWERK | — | — | X | — |
MENGENUMWERTUNG_VOLLSTAENDIG | — | — | X | — |
UHRZEIT_GESTELLT_SYNCHRONISATION | — | — | X | — |
MESSWERT_UNPLAUSIBEL | — | — | X | — |
FALSCHER_WANDLERFAKTOR | — | — | X | — |
FEHLERHAFTE_ABLESUNG | — | — | X | — |
AENDERUNG_DER_BERECHNUNG | — | — | X | — |
UMBAU_DER_MESSLOKATION | — | — | X | — |
DATENBEARBEITUNGSFEHLER | — | — | X | — |
BRENNWERTKORREKTUR | — | — | X | — |
Z_ZAHL_KORREKTUR | — | — | X | — |
STOERUNG_DEFEKT_MESSEINRICHTUNG | — | — | X | — |
AENDERUNG_TARIFSCHALTZEITEN | — | — | X | — |
TARIFSCHALTGERAET_DEFEKT | — | — | X | — |
IMPULSWERTIGKEIT_NICHT_AUSREICHEND | — | — | X | — |
ENERGIEMENGE_IN_UNGEMESSENEM_ZEITINTERVALL | — | — | X | — |
ENERGIEMENGE_AUS_DEM_UNGEPAIRTEN_ZEITINTERVALL | — | — | X | — |
WARTUNGSARBEITEN_AN_GEEICHTEM_MESSGERAET | — | — | X | — |
GESTOERTE_WERTE | — | — | X | — |
WARTUNGSARBEITEN_AN_EICHRECHTSKONFORMEN_MESSGERAETEN | — | — | X | — |
KONSISTENZ_UND_SYNCHRONPRUEFUNG | — | — | X | — |
GRUND_ANGABEN_MESSLOKATION | — | — | X | — |
ANFORDERUNG_IN_DIE_VERGANGENHEIT_ZUM_ANGEFORDERTEN_ZEITPUNKT_LIEGT_KEIN_WERT_VOR | — | — | X | — |
UMSTELLUNG_GASQUALITAET | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
GESCHEITERT | — | — | X | — |
AUSGEBAUT | — | — | X | — |
| ZAEHLER [ ] * | — | object[] | Must | — |
| zaehlernummer * 00150 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| transaktionsdaten * | — | object | Must | — |
| anfrageReferenz 00160 | Application number / RFF+AGI | string | X | — |
| dokumentennummer * 00170 | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| kategorie * 00180 | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| nachrichtendatum * 00190 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenfunktion * 00200 | Message function code / BGM | string | Must | — |
| nachrichtenreferenznummer * 00210 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00220 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00230 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00240 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00250 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00260 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 13002 | Condition |
|---|---|---|---|---|
| UNB | — | — | Must | — |
0001 UNOC00010 | UN/ECE character set C | — | X | — |
0002 300020 | Version 3 | — | X | — |
000400030 | MP-ID Sender | — | X | — |
0007 1400040 | GS1 | — | X | — |
0007 50200050 | DE, DVGW Service & Consult GmbH | — | X | — |
001000060 | MP-ID recipient | — | X | — |
0007 1400070 | GS1 | — | X | — |
0007 50200080 | DE, DVGW Service & Consult GmbH | — | X | — |
001700090 | Date of creation | — | X | — |
001900100 | Time of creation | — | X | — |
002000110 | Interchange control reference | — | X | [918] |
0026 VL00120 | Settlement list, meter reading | — | X | — |
0035 100130 | Transmission file is a test | — | — | S [155] |
| UNH | — | — | Must | — |
006200140 | Message reference number | — | X | — |
0065 MSCONS00150 | Report on the consumption of measurable services | — | X | — |
0052 D00160 | Draft version | — | X | — |
0054 04B00170 | Edition 2004 - B | — | X | — |
0051 UN00180 | UN/CEFACT | — | X | — |
0057 2.500190 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 700200 | Process data report | — | X | — |
100400210 | Document number | — | X | — |
1225 900220 | Original | — | X | — |
| DTM | — | — | Must | — |
2005 13700230 | Document-/message date/time | — | X | — |
238000240 | Date or time or time span, value | — | X | [931] [494] |
2379 30300250 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 AGI00260 | Application number | — | X | — |
115400270 | Reference number | — | X | [529] |
| SG1.RFF | — | — | Must | — |
1153 Z3000280 | Reference to previous master data notification of the MSB | — | X | — |
115400290 | Reference, identification | — | X | [530] |
| SG1.RFF | — | — | Must | — |
1153 Z1300300 | Check identifier | — | X | — |
1154 1300200310 | Meas. val. meter reading (gas) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00320 | Document-/message sender or sender | — | X | — |
303900330 | MP-ID | — | X | [118] |
3055 900340 | GS1 | — | X | — |
3055 33200350 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00360 | Message recipient | — | X | — |
303900370 | MP-ID | — | X | [118] |
3055 900380 | GS1 | — | X | — |
3055 33200390 | DE, DVGW Service & Consult GmbH | — | X | — |
| UNS | — | — | Must | — |
0081 D00400 | Separation of header and detail section | — | X | — |
| SG5.NAD | — | — | Must | — |
3035 DP00410 | Supply address | — | X | — |
| SG6.LOC | — | — | Must | — |
3227 17200420 | Reporting point | — | X | — |
322500430 | Designation | — | X | [951] [510] |
| SG7.RFF | — | — | Must | — |
1153 MG00440 | Device number | — | X | — |
115400450 | Device number | — | X | — |
| SG9.LIN | — | — | Must | — |
108200460 | Line item number | — | X | [908] |
| SG9.PIA | — | — | Must | — |
4347 500470 | Product identification | — | X | — |
714000480 | Medium / OBIS code number | — | X | [501] |
7143 SRW00490 | OBIS code | — | X | — |
| SG10.QTY | — | — | Must | — |
6063 22000500 | True value | — | X | — |
6063 6700510 | Substitute value | — | X | [32] |
6063 20100520 | Proposed value | — | X | [35] ∧ [36] ∧ [12] |
6063 2000530 | Unusable value | — | X | [35] ∧ [36] ∧ [12] |
6063 Z1800540 | Preliminary value | — | X | [32] ∧ [12] |
606000550 | Quantity | — | X | ([902] ∧ [906]) ∨ ([902] ∧ [907] [48]) |
| SG10.DTM | — | — | Must | [11] |
2005 16300560 | Processing, start date/time | — | X | — |
238000570 | Date or time or time span, value | — | X | [UB2] |
2379 30300580 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | [11] |
2005 16400590 | Processing, end date/time | — | X | — |
238000600 | Date or time or time span, value | — | X | [UB2] |
2379 30300610 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Should | [12] ∧ [93] ∧ [128] |
2005 900620 | Handling/processing date/time | — | X | — |
238000630 | Date or time or time span, value | — | X | ([931] [111] ∧ [495]) ⊻ ([134] ∧ [135]) |
2379 10200640 | CCYYMMDD | — | X | — |
2379 30300650 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | [12] |
2005 700660 | Effective date/time | — | X | — |
238000670 | Date or time or time span, value | — | X | [UB2] ∧ [495] ∧ ([130] ∨ [133]) |
2379 30300680 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Should | [12] ∧ [129] |
2005 6000690 | Design change date | — | X | — |
238000700 | Date or time or time span, value | — | X | [931] [495] |
2379 30300710 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.STS | — | — | Should | ([92] ⊻ [93] ⊻ [94]) ∧ [126] |
9015 Z3300720 | Plausibility check note | — | X | — |
9013 Z8300730 | Customer self-reading | — | X | [5P0..1] |
9013 Z8400740 | Vacancy | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 Z8500750 | Actual meter overflow checked | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 Z8600760 | Plausible due to check reading | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 Z8700770 | Plausible due to customer information | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 ZC300780 | Exchange of the substitute value | — | X | [5P0..1] |
9013 ZR500790 | Calculated value | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
| SG10.STS | — | — | Must | [92] ⊻ [94] |
9015 Z3200800 | Substitute value formation procedure | — | X | — |
9013 Z8900810 | Comparative measurement (not calibrated) | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9000820 | Meter reading value simulation from calibrated values | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9100830 | Meter reading value simulation from non-calibrated values | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9200840 | Interpolation | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9300850 | Hold value | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9400860 | Balancing grid section | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9500870 | Historical meter reading values | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZQ800880 | Distribution | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZQ900890 | Use of values from the fault quantity register | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZR000900 | Bypass and correction quantities | — | X | [4P0..1] ⊻ [6P0..1] |
| SG10.STS | — | — | Should | [127] ∧ [559] |
9015 Z3400910 | Reason for correction | — | X | — |
9013 Z7400920 | no access | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z7500930 | Communication fault | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z7600940 | Grid outage | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z7800950 | Device replacement | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z8000960 | Device operates outside the operating conditions | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z8100970 | Measuring equipment faulty/defective | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z8200980 | Measurement uncertainty | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z9800990 | Consideration of the fault quantity register | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9901000 | Volume conversion incomplete | — | X | [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA001010 | Time set /synchronisation | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA101020 | Meter reading value implausible | — | X | [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA401030 | Incorrect reading | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA501040 | Change of the calculation | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA601050 | Conversion of the metering location | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA701060 | Data processing error | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA801070 | Calorific value correction | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA901080 | Z-number correction | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZB001090 | Fault / defect of measuring equipment | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZC401100 | Pulse value not sufficient | — | X | [4P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR101110 | Maintenance work on a calibrated measuring device | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR201120 | faulty values | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR301130 | Maintenance work on measuring devices compliant with calibration law | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR401140 | Consistency and synchronisation check | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
| SG10.STS | — | — | Must | [92] |
9015 Z4001150 | Reason for substitute value formation | — | X | — |
9013 Z7401160 | no access | — | X | [4P0..1] |
9013 Z7501170 | Communication fault | — | X | [4P0..1] |
9013 Z7601180 | Grid outage | — | X | [4P0..1] |
9013 Z7801190 | Device replacement | — | X | [4P0..1] |
9013 Z8001200 | Device operates outside the operating conditions | — | X | [4P0..1] |
9013 Z8101210 | Measuring equipment faulty/defective | — | X | [4P0..1] |
9013 Z8201220 | Measurement uncertainty | — | X | [4P0..1] |
9013 Z9801230 | Consideration of the fault quantity register | — | X | [4P0..1] |
9013 Z9901240 | Volume conversion incomplete | — | X | [4P0..1] |
9013 ZA001250 | Time set /synchronisation | — | X | [4P0..1] |
9013 ZA101260 | Meter reading value implausible | — | X | [4P0..1] |
9013 ZA401270 | Incorrect reading | — | X | [4P0..1] |
9013 ZA501280 | Change of the calculation | — | X | [4P0..1] |
9013 ZA601290 | Conversion of the metering location | — | X | [4P0..1] |
9013 ZA701300 | Data processing error | — | X | [4P0..1] |
9013 ZB001310 | Fault / defect of measuring equipment | — | X | [4P0..1] |
9013 ZC401320 | Pulse value not sufficient | — | X | [4P0..1] |
9013 ZR101330 | Maintenance work on a calibrated measuring device | — | X | [4P0..1] |
9013 ZR201340 | faulty values | — | X | [4P0..1] |
9013 ZR301350 | Maintenance work on measuring devices compliant with calibration law | — | X | [4P0..1] |
9013 ZR401360 | Consistency and synchronisation check | — | X | [4P0..1] |
9013 ZT801370 | Request into the past; no value is available for the requested point in time. | — | X | [4P0..1] |
| SG10.STS | — | — | Should | [97] |
9015 Z3101380 | Gas quality | — | X | — |
9013 ZG301390 | Change of gas quality | — | X | — |
| UNT | — | — | Must | — |
007401400 | Number of segments in a message | — | X | — |
006201410 | Message reference number | — | X | — |
| UNZ | — | — | Must | — |
003601420 | Interchange counter | — | X | — |
002001430 | Interchange control reference | — | X | — |
Conditions of this table
The free text of the 41 conditions referenced by the rows above. All conditions of the message type are listed in the condition index MSCONS.
| Marker | Condition |
|---|---|
| [11] | If SG9 PIA+5+7-0?:52.0.22/7-0?:54.0.16/7-0?:54.0.20/7-0?:54.0.22 |
| [12] | If not SG9 PIA+5+7-0?:52.0.22/7-0?:54.0.16/7-0?:54.0.20/7-0?:54.0.22 |
| [32] | if MP-ID in SG2 NAD+MS in the role NB |
| [35] | if MP-ID in SG2 NAD+MS in the role MSB |
| [36] | if MP-ID in SG2 NAD+MR in the role NB |
| [48] | If SG9 PIA+5+7-0?:52.0.22 |
| [92] | If SG10 QTY DE6063 with value 67 is present |
| [93] | If SG10 QTY DE6063 with value 220 is present |
| [94] | If SG10 QTY DE6063 with value 201 is present |
| [97] | If this concerns the transmission of a value due to the change of the gas quality |
| [111] | If SG10 DTM+9 DE2379 with value 303 is present in the same segment |
| [118] | Only MP-ID from the gas division |
| [126] | if plausibility check notices exist |
| [127] | if a correction reason has to be stated |
| [128] | If this concerns a meter reading which is not a reading due to a change to the metering equipment or its configuration (e.g. customer reading). |
| [129] | If this concerns a meter reading due to a change to the metering equipment or its configuration (e.g. device replacement). |
| [130] | If, within the same LIN segment and in addition to this segment (SG10 DTM+7 usage point in time), the SG10 DTM+60 (execution / change point in time) or the SG10 DTM+9 (reading date) is also present, the value of the difference between the later and the earlier point in time of the DTM segments may only be < 24 hours. If the summer/winter time changeover takes place between the two points in time, the value of the difference may only be < 25 hours. If the winter/summer time changeover takes place between the two points in time, the value of the difference may only be < 23 hours. |
| [133] | If, within the same LIN segment and in addition to this segment (SG10 DTM+7 usage point in time), the SG10 DTM+9 (reading date) with the code 102 in DE2379 is also present, the value of the difference between the value at position CCYYMMDD of the later and the earlier point in time of the DTM segments at position CCYYMMDD may only be 0 or 1 day. |
| [134] | If SG10 DTM+9 DE2379 with value 102 is present in the same segment |
| [135] | The value at position CCYYMMDD must be ≤ the value at position CCYYMMDD in DE2380 of DTM+137 |
| [155] | If the transmission file is exchanged for test purposes. |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [501] | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| [510] | Note: Use of the ID of the metering location |
| [529] | Note: Value from BGM+7 DE1004 of the ORDERS with which the request for meter reading values was made. |
| [530] | Note: Value from SG4 IDE+24 DE7402 of the UTILMD with which the sender of the MSCONS transmitted the previous master data by means of UTILMD. |
| [559] | Note: A correction reason is to be specified if: 1. a preliminary value already transmitted to the MP is replaced by a substitute value after cancellation, or 2. a substitute value already transmitted to the MP is replaced by a substitute value after cancellation, or 3. a true value already transmitted to the MP is replaced by a substitute value after cancellation, or 4. a true value already transmitted to the MP is replaced by a true value after cancellation. |
| [902] | Format: Possible value: ≥ 0 |
| [906] | Format: max. 3 decimal places |
| [907] | Format: max. 4 decimal places |
| [908] | Format: possible values: 1 to n |
| [918] | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| [931] | Format: ZZZ = +00 |
| [951] | Format: Metering point identifier |
| [UB2] | ([931] ∧ [934] [490]) ⊻ ([931] ∧ [935] [491]) |
| [5P0..1] | [93] If SG10 QTY DE6063 with value 220 present |
| [4P0..1] | [92] If SG10 QTY DE6063 with value 67 present |
| [6P0..1] | [94] If SG10 QTY DE6063 with value 201 present |
| [7P0..1] | [95] If SG10 QTY DE6063 with value 20 present |
| [8P0..1] | [96] If SG10 QTY DE6063 with value Z18 present |
Example message
Example 1
UNA:+.? '
UNB+UNOC:3+9870000000001:502+9800100000002:502+{{date}}:{{time}}+P1001099269230++VL'
UNH+P1001099269231+MSCONS:D:04B:UN:2.5'
BGM+7+BGMM1Z3HQ32+9'
DTM+137:202410010607?+00:303'
RFF+AGI:PP172409301012154888888888888563413'
RFF+Z13:13002'
NAD+MS+9870000000001::332'
NAD+MR+9800100000002::332'
UNS+D'
NAD+DP'
LOC+172+DE7000874940100000000000070866366'
RFF+MG:30203458'
LIN+1'
PIA+5+7-20?:3.0.0:SRW'
QTY+67:9608'
DTM+7:202408020400?+00:303'
STS+Z32++Z92'
STS+Z34++ZA5'
STS+Z40++Z74'
LIN+2'
PIA+5+7-0?:54.0.22:SRW'
QTY+220:11.492'
DTM+163:202312220500?+00:303'
DTM+164:202408020400?+00:303'
STS+Z33++Z84'
STS+Z34++ZA5'
STS+Z31++ZG3'
LIN+3'
PIA+5+7-0?:52.0.22:SRW'
QTY+220:0.965'
DTM+163:202312220500?+00:303'
DTM+164:202408020400?+00:303'
STS+Z33++Z84'
STS+Z34++ZA5'
STS+Z31++ZG3'
UNT+35+P1001099269231'
UNZ+1+P1001099269230'[1 item
{6 fields
"data": {3 fields
"stammdaten": {2 fields
"ZAEHLER": [1 item
{4 fields
"ENERGIEMENGE": [1 item
{5 fields
"energieverbrauch": [3 items
{6 fields
"statuszusatzinformationen": [3 items
{2 fields
{2 fields
{2 fields
{7 fields
"statuszusatzinformationen": [3 items
{2 fields
{2 fields
{2 fields
{7 fields
"statuszusatzinformationen": [3 items
{2 fields
{2 fields
{2 fields
"transaktionsdaten": {12 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 2
UNA:+.? '
UNB+UNOC:3+9800044300007:502+9870013800007:502+{{date}}:{{time}}+PPPCJOFDQJUETW++VL'
UNH+PPPCJOFDQJUETW+MSCONS:D:04B:UN:2.5'
BGM+7+BGMM24BMWLD+9'
DTM+137:202610011100?+00:303'
RFF+AGI:AFN9523'
RFF+Z30:AFN9523'
RFF+Z13:13002'
NAD+MS+9800044300007::332'
NAD+MR+9870013800007::332'
UNS+D'
NAD+DP'
LOC+172+DE7000872667600000001000000000001'
RFF+MG:7ELS2535000000'
LIN+1'
PIA+5+7-0?:3.0.0:SRW'
QTY+220:3797'
DTM+9:202506292200?+00:303'
DTM+7:202507010400?+00:303'
STS+Z33++Z83'
UNT+19+PPPCJOFDQJUETW'
UNZ+1+PPPCJOFDQJUETW'[1 item
{6 fields
"data": {3 fields
"stammdaten": {2 fields
"ZAEHLER": [1 item
{4 fields
"ENERGIEMENGE": [1 item
{6 fields
"energieverbrauch": [1 item
{7 fields
"statuszusatzinformationen": [1 item
{2 fields
"transaktionsdaten": {12 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Meter reading (gas) |
| AHB | MSCONS AHB |
| Response to check identifier | 17102 |
| Transmission channel | AS4 |
This check identifier is used in 29 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| Guideline on market processes for grid operator change | Value transmission Gas to NB | NBA → NBN | Values metering location |
| GeLi Gas 2.0 | GeLi_Gas 2.0 ch. 4.1.1.1 Collection of measured values | LF → NB | — |
| GeLi Gas 2.0 | Request and provision of meter reading values | MSB → NB | Meter reading transmission |
| GeLi Gas 2.0 | Request and provision of meter reading values | NB → MSB | Transmission of substitute values |
| GeLi Gas 2.0 | Request and provision of meter reading values | NB → LF | Meter reading transmission |
| GeLi Gas 2.0 | Periodic/regular meter reading transmission | MSB → NB | Meter reading date for measuring equipment with balancing based on profiles |
| GeLi Gas 2.0 | Periodic/regular meter reading transmission | MSB → NB | Regular reading of measuring equipment with RLM |
| GeLi Gas 2.0 | Off-cycle meter reading transmission | MSB → NB | Start of supply/ start of substitute/ basic supply |
| GeLi Gas 2.0 | Off-cycle meter reading transmission | MSB → NB | End of supply / deregistration request |
| GeLi Gas 2.0 | Off-cycle meter reading transmission | MSB → NB | Interim meter reading |
| GeLi Gas 2.0 | Off-cycle meter reading transmission | MSB → NB | Device replacement or change of configuration for measuring equipment connected to a SMGW (electricity)) |
| GeLi Gas 2.0 | Business data request from LF to NB | NB → LF | Response |
| GeLi Gas 2.0 | Billing of grid usage | NB → LF | ongoing meter reading values |
| AWH WiM gas 2.0 | Device replacement | MSBN → MSBA | Meter reading and point in time of the device removal |
| AWH WiM gas 2.0 | Transmission of values from LF to NB | LF → NB | Values |
| AWH WiM gas 2.0 | Transmission of values from MSB to NB | MSB → NB | Values |
| WiM gas | Ch. B 5.1.3 No. 7 | MSBN → NB | Transmission of final reading values by MSBN or MSBA |
| WiM gas | Ch. B 5.1.3 No. 7 | MSBA → NB | Transmission of final reading values by MSBN or MSBA |
| WiM gas | Ch. B 5.1.3 No. 8 | MSBN → NB | Notification of device replacement, master data and installation meter reading |
| GeLi Gas | Ch. D 1.1.1 | LF → NB | — |
| GeLi Gas | Ch. D 1.2.4 No. 11 | NB → LF | Meter reading transmission |
| GeLi Gas | Ch. D 1.2.4 No. 7 | MSB → NB | Meter reading transmission |
| GeLi Gas | Ch. D 1.2.4 No. 9 | NB → MSB | Transmission of substitute values |
| GeLi Gas | Ch. D 2.2 No. 2 | NB → LF | Response |
| GeLi Gas | Ch. D 2.3 No. 2 | NB → MSB | Response |
| GeLi Gas | Ch. D 3.2 No. 2 | NB → LF | Response |
| WiM gas | UF GeLiGas_006 business data request from NB to MSB | MSB → NB | Response |
| GeLi Gas | Ch. D 1.2.3 No. 7 | MSB → NB | Meter reading transmission |
| GeLi Gas | Ch. D 1.2.3 No. 9 | NB → MSB | Transmission of substitute values |
Individual entries from format version 202604
The check identifiers table of format version 202610 does not carry this entry: process step. It comes from version 202604. Version 202604 also carries this check identifier in contexts that the table of version 202610 does not know; they are included in the list above. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202610.
Transaction and responses
Role of this check identifier: response. Basis: the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 17102 | Request for values | ORDERS | explicit |
Forwarding (triangular communication): The preceding step holds 21010 with the same send direction. This message therefore does not answer the sender of the preceding step, it forwards — which is why there is no response sentence here.
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfrageReferenz | SG1.RFF+AGI | dokumentennummer |
RFF+AGI quotes the BGM of the request; the target is its dokumentennummer. Measured: 17102 carries dokumentennummer in BGM+[7|Z28|Z48].
Check identifiers of the same AHB table: No other check identifier of message type MSCONS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 171 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains 2 transactions for this check identifier under the message type mscons. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.