Check identifier 13008 — Load curve (Gas)
Check identifier 13008 · EDIFACT message type MSCONS · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 13008 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| ENERGIEMENGE [ ] * | — | object[] | Must | — |
| enddatum * 00010 | Specifies the day and time (if available) when the time period ends. | string (date-time) | X | — |
| konfiguration 00020 | konfiguration | string | X | — |
| lokationsId * 00030 | Unique number of the market location or of the metering location to which the energy quantity belongs | string | X | — |
| startdatum * 00040 | Specifies the day and time (if available) when the time period starts. | string (date-time) | X | — |
| energieverbrauch [ ] * | — | object[] | Must | — |
| enddatum * 00050 | enddatum | string (date-time) | X | — |
| messwertstatus * 00060 | The status of a meter reading | Enum Messwertstatus | Must | — |
ABGELESEN | — | — | Must | — |
ERSATZWERT | — | — | Must | — |
VORSCHLAGSWERT | — | — | Must | — |
NICHT_VERWENDBAR | — | — | Must | — |
PROGNOSEWERT | — | — | Must | — |
ENERGIEMENGESUMMIERT | — | — | Must | — |
VOLAEUFIGERWERT | — | — | Must | — |
FEHLT | — | — | Must | — |
ANGABE_FUER_LIEFERSCHEIN | — | — | Must | — |
GRUNDLAGE_POG_ERMITTLUNG | — | — | Must | — |
| obiskennzahl * 00070 | obiskennzahl | string | X | — |
| position * 00080 | position | integer | Must | — |
| startdatum * 00090 | startdatum | string (date-time) | X | — |
| wert * 00100 | wert | number (float) | Must | — |
| statuszusatzinformationen [ ] | — | object[] | May | — |
| art 00110 | Status type | Enum StatusArt | X | — |
PLAUSIBILISIERUNGSHINWEIS | — | — | X | — |
ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
KORREKTURGRUND | — | — | X | — |
GRUND_ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
GASQUALITAET | — | — | X | — |
MESSKLASSIFIZIERUNG | — | — | X | — |
| status 00120 | Status | Enum Status | X | — |
KUNDENSELBSTABLESUNG | — | — | X | — |
LEERSTAND | — | — | X | — |
REALER_ZAEHLERUEBERLAUF_GEPRUEFT | — | — | X | — |
PLAUSIBEL_WG_KONTROLLABLESUNG | — | — | X | — |
PLAUSIBEL_WG_KUNDENHINWEIS | — | — | X | — |
AUSTAUSCH_DES_ERSATZWERTES | — | — | X | — |
RECHENWERT | — | — | X | — |
BASIS_MME | — | — | X | — |
VERGLEICHSMESSUNG_GEEICHT | — | — | X | — |
VERGLEICHSMESSUNG_NICHT_GEEICHT | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_GEEICHTEN_WERTEN | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_NICHT_GEEICHTEN_WERTEN | — | — | X | — |
INTERPOLATION | — | — | X | — |
HALTEWERT | — | — | X | — |
BILANZIERUNG_NETZABSCHNITT | — | — | X | — |
HISTORISCHE_MESSWERTE | — | — | X | — |
STATISTISCHE_METHODE | — | — | X | — |
AUFTEILUNG | — | — | X | — |
VERWENDUNG_VON_WERTEN_DES_STOERMENGENZAEHLWERKS | — | — | X | — |
UMGANGS_UND_KORREKTURMENGEN | — | — | X | — |
ANGABEN_MESSLOKATION | — | — | X | — |
KEIN_ZUGANG | — | — | X | — |
KOMMUNIKATIONSSTOERUNG | — | — | X | — |
NETZAUSFALL | — | — | X | — |
SPANNUNGSAUSFALL | — | — | X | — |
STATUS_GERAETEWECHSEL | — | — | X | — |
KALIBRIERUNG | — | — | X | — |
GERAET_ARBEITET_AUSSERHALB_DER_BETRIEBSBEDINGUNGEN | — | — | X | — |
MESSEINRICHTUNG_GESTOERT_DEFEKT | — | — | X | — |
UNSICHERHEIT_MESSUNG | — | — | X | — |
BERUECKSICHTIGUNG_STOERMENGENZAEHLWERK | — | — | X | — |
MENGENUMWERTUNG_VOLLSTAENDIG | — | — | X | — |
UHRZEIT_GESTELLT_SYNCHRONISATION | — | — | X | — |
MESSWERT_UNPLAUSIBEL | — | — | X | — |
FALSCHER_WANDLERFAKTOR | — | — | X | — |
FEHLERHAFTE_ABLESUNG | — | — | X | — |
AENDERUNG_DER_BERECHNUNG | — | — | X | — |
UMBAU_DER_MESSLOKATION | — | — | X | — |
DATENBEARBEITUNGSFEHLER | — | — | X | — |
BRENNWERTKORREKTUR | — | — | X | — |
Z_ZAHL_KORREKTUR | — | — | X | — |
STOERUNG_DEFEKT_MESSEINRICHTUNG | — | — | X | — |
AENDERUNG_TARIFSCHALTZEITEN | — | — | X | — |
TARIFSCHALTGERAET_DEFEKT | — | — | X | — |
IMPULSWERTIGKEIT_NICHT_AUSREICHEND | — | — | X | — |
ENERGIEMENGE_IN_UNGEMESSENEM_ZEITINTERVALL | — | — | X | — |
ENERGIEMENGE_AUS_DEM_UNGEPAIRTEN_ZEITINTERVALL | — | — | X | — |
WARTUNGSARBEITEN_AN_GEEICHTEM_MESSGERAET | — | — | X | — |
GESTOERTE_WERTE | — | — | X | — |
WARTUNGSARBEITEN_AN_EICHRECHTSKONFORMEN_MESSGERAETEN | — | — | X | — |
KONSISTENZ_UND_SYNCHRONPRUEFUNG | — | — | X | — |
GRUND_ANGABEN_MESSLOKATION | — | — | X | — |
ANFORDERUNG_IN_DIE_VERGANGENHEIT_ZUM_ANGEFORDERTEN_ZEITPUNKT_LIEGT_KEIN_WERT_VOR | — | — | X | — |
UMSTELLUNG_GASQUALITAET | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
GESCHEITERT | — | — | X | — |
AUSGEBAUT | — | — | X | — |
| transaktionsdaten * | — | object | Must | — |
| anfrageReferenz 00130 | Application number / RFF+AGI | string | X | — |
| dokumentennummer * 00140 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| kategorie * 00150 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 00160 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenfunktion * 00170 | Message function code / BGM | string | X | — |
| nachrichtenreferenznummer * 00180 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00190 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00200 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00210 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00220 | Email address | string | Must | — |
| nachname 00230 | Surname (family name) of the contact person | string | X | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00240 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00250 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00260 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00270 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 13008 | Condition |
|---|---|---|---|---|
| UNB | — | — | Must | — |
0001 UNOC00010 | UN/ECE character set C | — | X | — |
0002 300020 | Version 3 | — | X | — |
000400030 | MP-ID Sender | — | X | — |
0007 1400040 | GS1 | — | X | — |
0007 50200050 | DE, DVGW Service & Consult GmbH | — | X | — |
001000060 | MP-ID recipient | — | X | — |
0007 1400070 | GS1 | — | X | — |
0007 50200080 | DE, DVGW Service & Consult GmbH | — | X | — |
001700090 | Date of creation | — | X | — |
001900100 | Time of creation | — | X | — |
002000110 | Interchange control reference | — | X | [918] |
0026 TL00120 | Load curve, any time period | — | X | — |
| UNH | — | — | Must | — |
006200130 | Message reference number | — | X | — |
0065 MSCONS00140 | Report on the consumption of measurable services | — | X | — |
0052 D00150 | Draft version | — | X | — |
0054 04B00160 | Edition 2004 - B | — | X | — |
0051 UN00170 | UN/CEFACT | — | X | — |
0057 2.4c00180 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 700190 | Process data report | — | X | — |
100400200 | Document number | — | X | — |
1225 900210 | Original | — | X | — |
| DTM | — | — | Must | — |
2005 13700220 | Document-/message date/time | — | X | — |
238000230 | Date or time or time span, value | — | X | [931] [494] |
2379 30300240 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 AGI00250 | Application number | — | X | — |
115400260 | Reference number | — | X | [529] ∨ [553] |
| SG1.RFF | — | — | Must | — |
1153 Z1300270 | Check identifier | — | X | — |
1154 1300800280 | Meter reading value load curve (gas) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00290 | Document-/message sender or sender | — | X | — |
303900300 | MP-ID | — | X | [118] |
3055 900310 | GS1 | — | X | — |
3055 33200320 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG4.CTA | — | — | Must | — |
3139 IC00330 | Information point | — | X | — |
341200340 | Department or contact person | — | X | — |
| SG4.COM | — | — | Must | — |
314800350 | Communication address, identification | — | X | (([939] [142]) ∨ ([940] [143])) ∧ [576] |
3155 TE00360 | Telephone | — | X | [1P0..1] |
3155 EM00370 | — | X | [1P0..1] | |
3155 AJ00380 | further telephone | — | X | [1P0..1] |
3155 AL00390 | Mobile phone | — | X | [1P0..1] |
3155 FX00400 | Fax number | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00410 | Message recipient | — | X | — |
303900420 | MP-ID | — | X | [118] |
3055 900430 | GS1 | — | X | — |
3055 33200440 | DE, DVGW Service & Consult GmbH | — | X | — |
| UNS | — | — | Must | — |
0081 D00450 | Separation of header and detail section | — | X | — |
| SG5.NAD | — | — | Must | — |
3035 DP00460 | Supply address | — | X | — |
| SG6.LOC | — | — | Must | — |
3227 17200470 | Reporting point | — | X | — |
322500480 | Designation | — | X | ([951] (([35] ∧ [36]) ∨ ([32] ∧ [42]) ∧ [510]) ∨ ([32] ∧ [36] ∧ [535]) ∨ ([32] ∧ [33] ∧ [519])) ⊻ ([950] ([32] ∧ [33]) ∧ ([514] ∧ [520])) ⊻ ([950] [32] ∧ [141] ∧ [514]) |
| SG6.DTM | — | — | Must | — |
2005 16300490 | Processing, start date/time | — | X | — |
238000500 | Date or time or time span, value | — | X | [931] |
2379 30300510 | CCYYMMDDHHMMZZZ | — | X | — |
| SG6.DTM | — | — | Must | — |
2005 16400520 | Processing, end date/time | — | X | — |
238000530 | Date or time or time span, value | — | X | [931] |
2379 30300540 | CCYYMMDDHHMMZZZ | — | X | — |
| SG9.LIN | — | — | Must | — |
108200550 | Line item number | — | X | [908] |
| SG9.PIA | — | — | Must | — |
4347 500560 | Product identification | — | X | — |
714000570 | Medium / OBIS code number | — | X | [501] ⊻ ([108] ∧ [36]) |
7143 SRW00580 | OBIS code | — | X | — |
| SG10.QTY | — | — | Must | — |
6063 22000590 | True value | — | X | — |
6063 6700600 | Substitute value | — | X | ([32] ∧ ([33] ∨ [36] ∨ [42] ∨ [141])) |
6063 20100610 | Proposed value | — | X | ([35] ∧ [36]) |
6063 2000620 | Unusable value | — | X | ([35] ∧ [36]) ⊻ ([32] ∧ [33] ∧ [506]) |
6063 18700630 | Forecast value | — | X | [32] ∧ ([33] ∨ [36] ∨ [141]) ∧ [11] |
6063 Z1800640 | Preliminary value | — | X | [32] ∧ ([33] ∨ [141]) |
606000650 | Quantity | — | X | ([902] ∧ [906]) ∨ ([902] ∧ [907] [125]) ∨ ([910] ∧ [907] [45]) |
| SG10.DTM | — | — | Must | — |
2005 16300660 | Processing, start date/time | — | X | — |
238000670 | Date or time or time span, value | — | X | [931] |
2379 30300680 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | — |
2005 16400690 | Processing, end date/time | — | X | — |
238000700 | Date or time or time span, value | — | X | [931] |
2379 30300710 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.STS | — | — | Should | ([92] ⊻ [93] ⊻ [94]) ∧ [126] |
9015 Z3300720 | Plausibility check note | — | X | — |
9013 Z8300730 | Customer self-reading | — | X | [5P0..1] |
9013 Z8400740 | Vacancy | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 Z8500750 | Actual meter overflow checked | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 Z8600760 | Plausible due to check reading | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 Z8700770 | Plausible due to customer information | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 ZC300780 | Exchange of the substitute value | — | X | [5P0..1] |
9013 ZR500790 | Calculated value | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
| SG10.STS | — | — | Must | [92] ⊻ [94] |
9015 Z3200800 | Substitute value formation procedure | — | X | — |
9013 Z8900810 | Comparative measurement (not calibrated) | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9000820 | Meter reading value simulation from calibrated values | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9100830 | Meter reading value simulation from non-calibrated values | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9200840 | Interpolation | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9300850 | Hold value | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9400860 | Balancing grid section | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9500870 | Historical meter reading values | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZQ800880 | Distribution | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZQ900890 | Use of values from the fault quantity register | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZR000900 | Bypass and correction quantities | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZS000910 | Substitute value procedure according to the details at the level of the metering location | — | X | ([46] ∧ [568]) ⊻ ([32] ∧ [36] ∧ [572]) |
| SG10.STS | — | — | Should | [127] ∧ [560] |
9015 Z3400920 | Reason for correction | — | X | — |
9013 Z7400930 | no access | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z7500940 | Communication fault | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z7600950 | Grid outage | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z7800960 | Device replacement | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z8000970 | Device operates outside the operating conditions | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z8100980 | Measuring equipment faulty/defective | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z8200990 | Measurement uncertainty | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z9801000 | Consideration of the fault quantity register | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9901010 | Volume conversion incomplete | — | X | [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA001020 | Time set /synchronisation | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA101030 | Meter reading value implausible | — | X | [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA401040 | Incorrect reading | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA501050 | Change of the calculation | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA601060 | Conversion of the metering location | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA701070 | Data processing error | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA801080 | Calorific value correction | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA901090 | Z-number correction | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZB001100 | Fault / defect of measuring equipment | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZC401110 | Pulse value not sufficient | — | X | [4P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZJ901120 | Energy quantity from the unpaired time interval | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZR101130 | Maintenance work on a calibrated measuring device | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR201140 | faulty values | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR301150 | Maintenance work on measuring devices compliant with calibration law | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR401160 | Consistency and synchronisation check | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
| SG10.STS | — | — | Must | [92] |
9015 Z4001170 | Reason for substitute value formation | — | X | — |
9013 Z7401180 | no access | — | X | [4P0..1] |
9013 Z7501190 | Communication fault | — | X | [4P0..1] |
9013 Z7601200 | Grid outage | — | X | [4P0..1] |
9013 Z7801210 | Device replacement | — | X | [4P0..1] |
9013 Z8001220 | Device operates outside the operating conditions | — | X | [4P0..1] |
9013 Z8101230 | Measuring equipment faulty/defective | — | X | [4P0..1] |
9013 Z8201240 | Measurement uncertainty | — | X | [4P0..1] |
9013 Z9801250 | Consideration of the fault quantity register | — | X | [4P0..1] |
9013 Z9901260 | Volume conversion incomplete | — | X | [4P0..1] |
9013 ZA001270 | Time set /synchronisation | — | X | [4P0..1] |
9013 ZA101280 | Meter reading value implausible | — | X | [4P0..1] |
9013 ZA401290 | Incorrect reading | — | X | [4P0..1] |
9013 ZA501300 | Change of the calculation | — | X | [4P0..1] |
9013 ZA601310 | Conversion of the metering location | — | X | [4P0..1] |
9013 ZA701320 | Data processing error | — | X | [4P0..1] |
9013 ZB001330 | Fault / defect of measuring equipment | — | X | [4P0..1] |
9013 ZC401340 | Pulse value not sufficient | — | X | [4P0..1] |
9013 ZR101350 | Maintenance work on a calibrated measuring device | — | X | [4P0..1] |
9013 ZR201360 | faulty values | — | X | [4P0..1] |
9013 ZR301370 | Maintenance work on measuring devices compliant with calibration law | — | X | [4P0..1] |
9013 ZR401380 | Consistency and synchronisation check | — | X | [4P0..1] |
9013 ZS901390 | Reason for substitute value formation according to the information at metering location level | — | X | ([46] ∧ [570]) ⊻ ([32] ∧ [36] ∧ [571]) |
| SG10.STS | — | — | Should | [97] |
9015 Z3101400 | Gas quality | — | X | — |
9013 ZG301410 | Change of gas quality | — | X | — |
| UNT | — | — | Must | — |
007401420 | Number of segments in a message | — | X | — |
006201430 | Message reference number | — | X | — |
| UNZ | — | — | Must | — |
003601440 | Interchange counter | — | X | — |
002001450 | Interchange control reference | — | X | — |
Conditions of this table
The free text of the 53 conditions referenced by the rows above. All conditions of the message type are listed in the condition index MSCONS.
| Marker | Condition |
|---|---|
| [11] | If SG9 PIA+5+7-0?:52.0.22/7-0?:54.0.16/7-0?:54.0.20/7-0?:54.0.22 |
| [32] | if MP-ID in SG2 NAD+MS in the role NB |
| [33] | if MP-ID in SG2 NAD+MR in the role LF |
| [35] | if MP-ID in SG2 NAD+MS in the role MSB |
| [36] | if MP-ID in SG2 NAD+MR in the role NB |
| [42] | If MP-ID in SG2 NAD+MR in the role MSB |
| [45] | If SG9 PIA+5+7-b:99.41.16 (b=channel: value according to the code list of the OBIS codes and media) is present |
| [46] | If the value in SG6 LOC+172 DE3225 has exactly 11 digits |
| [92] | If SG10 QTY DE6063 with value 67 is present |
| [93] | If SG10 QTY DE6063 with value 220 is present |
| [94] | If SG10 QTY DE6063 with value 201 is present |
| [97] | If this concerns the transmission of a value due to the change of the gas quality |
| [108] | if SG9 PIA+5+7-b?:99.41.16/7-b?:99.42.16 (b=channel: value according to the code list of OBIS identifiers and media) is present |
| [118] | Only MP-ID from the gas division |
| [125] | if SG9 PIA+5+7-0?:52.0.22/7-b?:53.0.16/7-b?:55.0.16/7-b?:55.0.20/7-b?:55.0.22 (b=channel: value according to the code list of OBIS identifiers and media) is present |
| [126] | if plausibility check notices exist |
| [127] | if a correction reason has to be stated |
| [141] | If MP-ID in SG2 NAD+MR in the role MGV |
| [142] | if the code EM is present in DE3155 in the same COM |
| [143] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [501] | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| [506] | Note: Only for feed-in quantities and, for gas, for hourly energy data transmission |
| [510] | Note: Use of the ID of the metering location |
| [514] | Note: Use of the ID of the market location |
| [519] | Note: Only if the measured load curve of the metering location does not correspond 1:1 to the load curve of the market location. |
| [520] | Note: If there is a 1:1 relationship between metering location and market location and the measured load curve of the metering location corresponds 1:1 to the load curve of the market location, or if the measured load curve does not correspond to the load curve of the market location. |
| [529] | Note: Value from BGM+7 DE1004 of the ORDERS with which the request for meter reading values was made. |
| [535] | Note: Use of the ID of the electricity/gas grid coupling point |
| [553] | Note: Value from BGM+Z34 DE1004 of the ORDERS with which the complaint regarding values was made |
| [560] | Note: A correction reason is to be specified if: 1. a preliminary value already transmitted to the MP is replaced by a substitute value, or 2. a substitute value already transmitted to the MP is replaced by a substitute value, or 3. a true value already transmitted to the MP is replaced by a substitute value, or 4. a true value already transmitted to the MP is replaced by a true value. |
| [568] | Note: Use is permitted only if it is a 1:n relationship between market and metering location and different substitute value determination procedures have been used and communicated at the level of the metering location. |
| [570] | Note: Use is permitted only if it is a 1:n relationship between market and metering location and different reasons for the substitute value determination exist at the level of the metering location and have been communicated. |
| [571] | Note: Use is permitted only if it is a 1:n relationship and different reasons for the substitute value determination exist at the level of the grid coupling points and have been communicated. |
| [572] | Note: Use is permitted only if it is a 1:n relationship and different substitute value determination procedures exist at the level of the grid coupling points and have been communicated. |
| [576] | Note: Only one piece of information may be transmitted in DE3148 |
| [902] | Format: Possible value: ≥ 0 |
| [906] | Format: max. 3 decimal places |
| [907] | Format: max. 4 decimal places |
| [908] | Format: possible values: 1 to n |
| [910] | Format: Possible value: < 0 or ≥ 0 |
| [918] | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment |
| [5P0..1] | [93] If SG10 QTY DE6063 with value 220 present |
| [4P0..1] | [92] If SG10 QTY DE6063 with value 67 present |
| [6P0..1] | [94] If SG10 QTY DE6063 with value 201 present |
| [7P0..1] | [95] If SG10 QTY DE6063 with value 20 present |
| [8P0..1] | [96] If SG10 QTY DE6063 with value Z18 present |
Example message
UNA:+.? '
UNB+UNOC:3+9870027900009:502+9800130000008:502+{{date}}:{{time}}+OF218453241++TL'
UNH+VL218453244+MSCONS:D:04B:UN:2.4c'
BGM+7+CL218453245+9'
DTM+137:202404030800?+00:303'
RFF+Z13:13008'
NAD+MS+9870027900009::332'
NAD+MR+9800130000008::332'
UNS+D'
NAD+DP'
LOC+172+10167038547'
DTM+163:202310050400?+00:303'
DTM+164:202310080400?+00:303'
LIN+1'
PIA+5+7-10?:99.33.17:SRW'
QTY+220:344.775'
DTM+163:202310050400?+00:303'
DTM+164:202310050500?+00:303'
QTY+220:318.477'
DTM+163:202310050500?+00:303'
DTM+164:202310050600?+00:303'
QTY+220:299.823'
DTM+163:202310050600?+00:303'
DTM+164:202310050700?+00:303'
QTY+220:293.332'
DTM+163:202310050700?+00:303'
DTM+164:202310050800?+00:303'
QTY+220:300.042'
DTM+163:202310050800?+00:303'
DTM+164:202310050900?+00:303'
QTY+220:295.673'
DTM+163:202310050900?+00:303'
DTM+164:202310051000?+00:303'
QTY+220:288.629'
DTM+163:202310051000?+00:303'
DTM+164:202310051100?+00:303'
QTY+220:295.996'
DTM+163:202310051100?+00:303'
DTM+164:202310051200?+00:303'
QTY+220:203.129'
DTM+163:202310051200?+00:303'
DTM+164:202310051300?+00:303'
QTY+220:75.031'
DTM+163:202310051300?+00:303'
DTM+164:202310051400?+00:303'
QTY+220:0'
DTM+163:202310051400?+00:303'
DTM+164:202310051500?+00:303'
QTY+220:0'
DTM+163:202310051500?+00:303'
DTM+164:202310051600?+00:303'
QTY+220:0'
DTM+163:202310051600?+00:303'
DTM+164:202310051700?+00:303'
QTY+220:0'
DTM+163:202310051700?+00:303'
DTM+164:202310051800?+00:303'
QTY+220:0'
DTM+163:202310051800?+00:303'
DTM+164:202310051900?+00:303'
QTY+220:0'
DTM+163:202310051900?+00:303'
DTM+164:202310052000?+00:303'
QTY+220:0'
DTM+163:202310052000?+00:303'
DTM+164:202310052100?+00:303'
QTY+220:0'
DTM+163:202310052100?+00:303'
DTM+164:202310052200?+00:303'
QTY+220:0'
DTM+163:202310052200?+00:303'
DTM+164:202310052300?+00:303'
QTY+220:0'
DTM+163:202310052300?+00:303'
DTM+164:202310060000?+00:303'
QTY+220:0'
DTM+163:202310060000?+00:303'
DTM+164:202310060100?+00:303'
QTY+220:0'
DTM+163:202310060100?+00:303'
DTM+164:202310060200?+00:303'
QTY+220:0'
DTM+163:202310060200?+00:303'
DTM+164:202310060300?+00:303'
QTY+220:0'
DTM+163:202310060300?+00:303'
DTM+164:202310060400?+00:303'
QTY+220:0'
DTM+163:202310060400?+00:303'
DTM+164:202310060500?+00:303'
QTY+220:12.198'
DTM+163:202310060500?+00:303'
DTM+164:202310060600?+00:303'
QTY+220:4.439'
DTM+163:202310060600?+00:303'
DTM+164:202310060700?+00:303'
QTY+220:1.118'
DTM+163:202310060700?+00:303'
DTM+164:202310060800?+00:303'
QTY+220:5.545'
DTM+163:202310060800?+00:303'
DTM+164:202310060900?+00:303'
QTY+220:3.332'
DTM+163:202310060900?+00:303'
DTM+164:202310061000?+00:303'
QTY+220:1.107'
DTM+163:202310061000?+00:303'
DTM+164:202310061100?+00:303'
QTY+220:0'
DTM+163:202310061100?+00:303'
DTM+164:202310061200?+00:303'
QTY+220:0'
DTM+163:202310061200?+00:303'
DTM+164:202310061300?+00:303'
QTY+220:0'
DTM+163:202310061300?+00:303'
DTM+164:202310061400?+00:303'
QTY+220:0'
DTM+163:202310061400?+00:303'
DTM+164:202310061500?+00:303'
QTY+220:0'
DTM+163:202310061500?+00:303'
DTM+164:202310061600?+00:303'
QTY+220:0'
DTM+163:202310061600?+00:303'
DTM+164:202310061700?+00:303'
QTY+220:0'
DTM+163:202310061700?+00:303'
DTM+164:202310061800?+00:303'
QTY+220:0'
DTM+163:202310061800?+00:303'
DTM+164:202310061900?+00:303'
QTY+220:0'
DTM+163:202310061900?+00:303'
DTM+164:202310062000?+00:303'
QTY+220:0'
DTM+163:202310062000?+00:303'
DTM+164:202310062100?+00:303'
QTY+220:0'
DTM+163:202310062100?+00:303'
DTM+164:202310062200?+00:303'
QTY+220:0'
DTM+163:202310062200?+00:303'
DTM+164:202310062300?+00:303'
QTY+220:0'
DTM+163:202310062300?+00:303'
DTM+164:202310070000?+00:303'
QTY+220:0'
DTM+163:202310070000?+00:303'
DTM+164:202310070100?+00:303'
QTY+220:0'
DTM+163:202310070100?+00:303'
DTM+164:202310070200?+00:303'
QTY+220:0'
DTM+163:202310070200?+00:303'
DTM+164:202310070300?+00:303'
QTY+220:12.163'
DTM+163:202310070300?+00:303'
DTM+164:202310070400?+00:303'
QTY+220:7.747'
DTM+163:202310070400?+00:303'
DTM+164:202310070500?+00:303'
QTY+220:0'
DTM+163:202310070500?+00:303'
DTM+164:202310070600?+00:303'
QTY+220:0'
DTM+163:202310070600?+00:303'
DTM+164:202310070700?+00:303'
QTY+220:0'
DTM+163:202310070700?+00:303'
DTM+164:202310070800?+00:303'
QTY+220:0'
DTM+163:202310070800?+00:303'
DTM+164:202310070900?+00:303'
QTY+220:0'
DTM+163:202310070900?+00:303'
DTM+164:202310071000?+00:303'
QTY+220:0'
DTM+163:202310071000?+00:303'
DTM+164:202310071100?+00:303'
QTY+220:0'
DTM+163:202310071100?+00:303'
DTM+164:202310071200?+00:303'
QTY+220:0'
DTM+163:202310071200?+00:303'
DTM+164:202310071300?+00:303'
QTY+220:0'
DTM+163:202310071300?+00:303'
DTM+164:202310071400?+00:303'
QTY+220:0'
DTM+163:202310071400?+00:303'
DTM+164:202310071500?+00:303'
QTY+220:0'
DTM+163:202310071500?+00:303'
DTM+164:202310071600?+00:303'
QTY+220:0'
DTM+163:202310071600?+00:303'
DTM+164:202310071700?+00:303'
QTY+220:0'
DTM+163:202310071700?+00:303'
DTM+164:202310071800?+00:303'
QTY+220:0'
DTM+163:202310071800?+00:303'
DTM+164:202310071900?+00:303'
QTY+220:0'
DTM+163:202310071900?+00:303'
DTM+164:202310072000?+00:303'
QTY+220:0'
DTM+163:202310072000?+00:303'
DTM+164:202310072100?+00:303'
QTY+220:0'
DTM+163:202310072100?+00:303'
DTM+164:202310072200?+00:303'
QTY+220:0'
DTM+163:202310072200?+00:303'
DTM+164:202310072300?+00:303'
QTY+220:0'
DTM+163:202310072300?+00:303'
DTM+164:202310080000?+00:303'
QTY+220:0'
DTM+163:202310080000?+00:303'
DTM+164:202310080100?+00:303'
QTY+220:0'
DTM+163:202310080100?+00:303'
DTM+164:202310080200?+00:303'
QTY+220:0'
DTM+163:202310080200?+00:303'
DTM+164:202310080300?+00:303'
QTY+220:15.46'
DTM+163:202310080300?+00:303'
DTM+164:202310080400?+00:303'
LIN+2'
PIA+5+7-0?:52.0.22:SRW'
QTY+187:1'
DTM+163:202310050400?+00:303'
DTM+164:202310080400?+00:303'
LIN+3'
PIA+5+7-0?:54.0.22:SRW'
QTY+187:11.529'
DTM+163:202310050400?+00:303'
DTM+164:202310080400?+00:303'
UNT+240+VL218453244'
UNZ+1+OF218453241'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"ENERGIEMENGE": [1 item
{7 fields
"energieverbrauch": [74 items
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
"transaktionsdaten": {11 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Load curve (gas) |
| AHB | MSCONS AHB |
| Response to check identifier | 17102 |
| Transmission channel | AS4 |
This check identifier is used in 34 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| KoV Leitfaden Marktprozesse Bilanzkreismanagement Gas | Ch. 5.5.5 | NB → NB | — |
| WiM gas | Ch. B 5.1.3 No. 7 | MSBN → NB | Transmission of final reading values by MSBN or MSBA |
| WiM gas | Ch. B 5.1.3 No. 7 | MSBA → NB | Transmission of final reading values by MSBN or MSBA |
| WiM gas | Ch. B 5.1.3 No. 8 | MSBN → NB | Notification of device replacement, master data and installation meter reading |
| WiM gas | Ch. C 4.3.1.2 No. 1a | NB → LF | Transmission of meter reading values (true values, substitute values, provisional values - 1st deadline) |
| WiM gas | Ch. C 4.3.1.2 No. 1b | NB → MSB | Transmission of substitute values |
| WiM gas | Ch. C 4.3.1.2 No. 2a | NB → LF | Transmission of true meter reading values |
| WiM gas | Ch. C 4.3.1.2 No. 2b | NB → LF | Transmission of substitute values |
| WiM gas | Ch. C 4.3.1.2 No. 2c | NB → MSB | Transmission of substitute values |
| WiM gas | Ch. C 4.3.2.2 No. 1 | NB → LF | billing-relevant meter reading values |
| WiM gas | Ch. C 4.3.2.2 No. 2 | NB → MSB | billing-relevant meter reading values |
| WiM gas | Ch. C 4.3.3.2 No. 2a | NB → LF | Consent to the complaint (corrected meter reading values) |
| WiM gas | Ch. C 4.3.3.2 No. 3 | NB → MSB | Transmission of corrected meter reading values |
| Market communication with the gas security platform | Transmission of values (load curve) from the NB to the MGV | NB → MGV | Values (load curve) |
| GeLi Gas 2.0 | Request and provision of meter reading values | MSB → NB | Meter reading transmission |
| GeLi Gas 2.0 | Request and provision of meter reading values | NB → MSB | Transmission of substitute values |
| GeLi Gas 2.0 | Request and provision of meter reading values | NB → LF | Meter reading transmission |
| GeLi Gas 2.0 | Periodic/regular meter reading transmission | MSB → NB | Regular reading of measuring equipment with RLM |
| GeLi Gas 2.0 | Off-cycle meter reading transmission | MSB → NB | Start of supply/ start of substitute/ basic supply |
| GeLi Gas 2.0 | Off-cycle meter reading transmission | MSB → NB | End of supply / deregistration request |
| GeLi Gas 2.0 | Off-cycle meter reading transmission | MSB → NB | Interim meter reading |
| GeLi Gas 2.0 | Off-cycle meter reading transmission | MSB → NB | Device replacement or change of configuration for measuring equipment connected to a SMGW (electricity)) |
| GeLi Gas 2.0 | Business data request from LF to NB | NB → LF | Response |
| GeLi Gas 2.0 | Billing of grid usage | NB → LF | ongoing meter reading values |
| AWH WiM gas 2.0 | Transmission of values from NB to LF | NB → LF | Values |
| AWH WiM gas 2.0 | Transmission of values from NB to MSB | NB → MSB | Values |
| AWH WiM gas 2.0 | Transmission of values from MSB to NB | MSB → NB | Values |
| GeLi Gas | Ch. D 1.2.4 No. 11 | NB → LF | Meter reading transmission |
| GeLi Gas | Ch. D 1.2.4 No. 7 | MSB → NB | Meter reading transmission |
| GeLi Gas | Ch. D 1.2.4 No. 9 | NB → MSB | Transmission of substitute values |
| GeLi Gas | Ch. D 2.2 No. 2 | NB → LF | Response |
| GeLi Gas | Ch. D 2.3 No. 2 | NB → MSB | Response |
| GeLi Gas | Ch. D 3.2 No. 2 | NB → LF | Response |
| WiM gas | UF GeLiGas_006 business data request from NB to MSB | MSB → NB | Response |
Further relationships from format version 202610
Version 202610 also carries this check identifier in contexts that the table of version 202604 does not know; they are included in the list above. Everything else on this page — use case, rulebook and communication direction — comes from the page's own version. Before adopting it into an implementation specification, check whether what is stated applies to 202604.
Transaction and responses
Role of this check identifier: response. Basis: the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 17102 | Request for values | ORDERS | explicit |
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfrageReferenz | SG1.RFF+AGI | dokumentennummer |
RFF+AGI quotes the BGM of the request; the target is its dokumentennummer. Measured: 17102 carries dokumentennummer in BGM+[7|Z28|Z48].
Check identifiers of the same AHB table: No other check identifier of message type MSCONS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 172 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type mscons. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.