Check identifier 13009 — Energy quantity (Gas)
Check identifier 13009 · EDIFACT message type MSCONS · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 13009 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| ENERGIEMENGE [ ] * | — | object[] | Must | — |
| konfiguration 00010 | konfiguration | string | X | — |
| lokationsId * 00020 | Unique number of the market location or of the metering location to which the energy quantity belongs | string | X | — |
| energieverbrauch [ ] * | — | object[] | Must | — |
| enddatum 00030 | enddatum | string (date-time) | X | — |
| leistungsperiode 00040 | leistungsperiode | string | X | — |
| messwertstatus * 00050 | The status of a meter reading | Enum Messwertstatus | Must | — |
ABGELESEN | — | — | Must | — |
ERSATZWERT | — | — | Must | — |
VORSCHLAGSWERT | — | — | Must | — |
NICHT_VERWENDBAR | — | — | Must | — |
PROGNOSEWERT | — | — | Must | — |
ENERGIEMENGESUMMIERT | — | — | Must | — |
VOLAEUFIGERWERT | — | — | Must | — |
FEHLT | — | — | Must | — |
ANGABE_FUER_LIEFERSCHEIN | — | — | Must | — |
GRUNDLAGE_POG_ERMITTLUNG | — | — | Must | — |
| obiskennzahl * 00060 | obiskennzahl | string | X | — |
| position * 00070 | position | integer | Must | — |
| startdatum 00080 | startdatum | string (date-time) | X | — |
| wert * 00090 | wert | number (float) | Must | — |
| statuszusatzinformationen [ ] | — | object[] | May | — |
| art 00100 | Status type | Enum StatusArt | X | — |
PLAUSIBILISIERUNGSHINWEIS | — | — | X | — |
ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
KORREKTURGRUND | — | — | X | — |
GRUND_ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
GASQUALITAET | — | — | X | — |
MESSKLASSIFIZIERUNG | — | — | X | — |
| status 00110 | Status | Enum Status | X | — |
KUNDENSELBSTABLESUNG | — | — | X | — |
LEERSTAND | — | — | X | — |
REALER_ZAEHLERUEBERLAUF_GEPRUEFT | — | — | X | — |
PLAUSIBEL_WG_KONTROLLABLESUNG | — | — | X | — |
PLAUSIBEL_WG_KUNDENHINWEIS | — | — | X | — |
AUSTAUSCH_DES_ERSATZWERTES | — | — | X | — |
RECHENWERT | — | — | X | — |
BASIS_MME | — | — | X | — |
VERGLEICHSMESSUNG_GEEICHT | — | — | X | — |
VERGLEICHSMESSUNG_NICHT_GEEICHT | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_GEEICHTEN_WERTEN | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_NICHT_GEEICHTEN_WERTEN | — | — | X | — |
INTERPOLATION | — | — | X | — |
HALTEWERT | — | — | X | — |
BILANZIERUNG_NETZABSCHNITT | — | — | X | — |
HISTORISCHE_MESSWERTE | — | — | X | — |
STATISTISCHE_METHODE | — | — | X | — |
AUFTEILUNG | — | — | X | — |
VERWENDUNG_VON_WERTEN_DES_STOERMENGENZAEHLWERKS | — | — | X | — |
UMGANGS_UND_KORREKTURMENGEN | — | — | X | — |
ANGABEN_MESSLOKATION | — | — | X | — |
KEIN_ZUGANG | — | — | X | — |
KOMMUNIKATIONSSTOERUNG | — | — | X | — |
NETZAUSFALL | — | — | X | — |
SPANNUNGSAUSFALL | — | — | X | — |
STATUS_GERAETEWECHSEL | — | — | X | — |
KALIBRIERUNG | — | — | X | — |
GERAET_ARBEITET_AUSSERHALB_DER_BETRIEBSBEDINGUNGEN | — | — | X | — |
MESSEINRICHTUNG_GESTOERT_DEFEKT | — | — | X | — |
UNSICHERHEIT_MESSUNG | — | — | X | — |
BERUECKSICHTIGUNG_STOERMENGENZAEHLWERK | — | — | X | — |
MENGENUMWERTUNG_VOLLSTAENDIG | — | — | X | — |
UHRZEIT_GESTELLT_SYNCHRONISATION | — | — | X | — |
MESSWERT_UNPLAUSIBEL | — | — | X | — |
FALSCHER_WANDLERFAKTOR | — | — | X | — |
FEHLERHAFTE_ABLESUNG | — | — | X | — |
AENDERUNG_DER_BERECHNUNG | — | — | X | — |
UMBAU_DER_MESSLOKATION | — | — | X | — |
DATENBEARBEITUNGSFEHLER | — | — | X | — |
BRENNWERTKORREKTUR | — | — | X | — |
Z_ZAHL_KORREKTUR | — | — | X | — |
STOERUNG_DEFEKT_MESSEINRICHTUNG | — | — | X | — |
AENDERUNG_TARIFSCHALTZEITEN | — | — | X | — |
TARIFSCHALTGERAET_DEFEKT | — | — | X | — |
IMPULSWERTIGKEIT_NICHT_AUSREICHEND | — | — | X | — |
ENERGIEMENGE_IN_UNGEMESSENEM_ZEITINTERVALL | — | — | X | — |
ENERGIEMENGE_AUS_DEM_UNGEPAIRTEN_ZEITINTERVALL | — | — | X | — |
WARTUNGSARBEITEN_AN_GEEICHTEM_MESSGERAET | — | — | X | — |
GESTOERTE_WERTE | — | — | X | — |
WARTUNGSARBEITEN_AN_EICHRECHTSKONFORMEN_MESSGERAETEN | — | — | X | — |
KONSISTENZ_UND_SYNCHRONPRUEFUNG | — | — | X | — |
GRUND_ANGABEN_MESSLOKATION | — | — | X | — |
ANFORDERUNG_IN_DIE_VERGANGENHEIT_ZUM_ANGEFORDERTEN_ZEITPUNKT_LIEGT_KEIN_WERT_VOR | — | — | X | — |
UMSTELLUNG_GASQUALITAET | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
GESCHEITERT | — | — | X | — |
AUSGEBAUT | — | — | X | — |
| transaktionsdaten * | — | object | Must | — |
| anfrageReferenz 00120 | Application number / RFF+AGI | string | X | — |
| dokumentennummer * 00130 | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| kategorie * 00140 | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| nachrichtendatum * 00150 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenfunktion * 00160 | Message function code / BGM | string | Must | — |
| nachrichtenreferenznummer * 00170 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00180 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00190 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00200 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00210 | Email address | string | Must | — |
| nachname 00220 | Surname (family name) of the contact person | string | X | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00230 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00240 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00250 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00260 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 13009 | Condition |
|---|---|---|---|---|
| UNB | — | — | Must | — |
0001 UNOC00010 | UN/ECE character set C | — | X | — |
0002 300020 | Version 3 | — | X | — |
000400030 | MP-ID Sender | — | X | — |
0007 1400040 | GS1 | — | X | — |
0007 50200050 | DE, DVGW Service & Consult GmbH | — | X | — |
001000060 | MP-ID recipient | — | X | — |
0007 1400070 | GS1 | — | X | — |
0007 50200080 | DE, DVGW Service & Consult GmbH | — | X | — |
001700090 | Date of creation | — | X | — |
001900100 | Time of creation | — | X | — |
002000110 | Interchange control reference | — | X | [918] |
0026 EM00120 | Energy quantity | — | X | — |
| UNH | — | — | Must | — |
006200130 | Message reference number | — | X | — |
0065 MSCONS00140 | Report on the consumption of measurable services | — | X | — |
0052 D00150 | Draft version | — | X | — |
0054 04B00160 | Edition 2004 - B | — | X | — |
0051 UN00170 | UN/CEFACT | — | X | — |
0057 2.4c00180 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 700190 | Process data report | — | X | — |
1001 Z2700200 | Transaction data in the calendar year before the start of supply | — | X | — |
100400210 | Document number | — | X | — |
1225 900220 | Original | — | X | — |
| DTM | — | — | Must | — |
2005 13700230 | Document-/message date/time | — | X | — |
238000240 | Date or time or time span, value | — | X | [931] [494] |
2379 30300250 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 AGI00260 | Application number | — | X | — |
115400270 | Reference number | — | X | [529] ⊻ ([531] ∧ [509]) |
| SG1.RFF | — | — | Must | — |
1153 Z1300280 | Check identifier | — | X | — |
1154 1300900290 | Meter reading value energy quantity (gas) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00300 | Document-/message sender or sender | — | X | — |
303900310 | MP-ID | — | X | [118] |
3055 900320 | GS1 | — | X | — |
3055 33200330 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG4.CTA | — | — | Must | — |
3139 IC00340 | Information point | — | X | — |
341200350 | Department or contact person | — | X | — |
| SG4.COM | — | — | Must | — |
314800360 | Communication address, identification | — | X | (([939] [142]) ∨ ([940] [143])) ∧ [576] |
3155 TE00370 | Telephone | — | X | [1P0..1] |
3155 EM00380 | — | X | [1P0..1] | |
3155 AJ00390 | further telephone | — | X | [1P0..1] |
3155 AL00400 | Mobile phone | — | X | [1P0..1] |
3155 FX00410 | Fax number | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00420 | Message recipient | — | X | — |
303900430 | MP-ID | — | X | [118] |
3055 900440 | GS1 | — | X | — |
3055 33200450 | DE, DVGW Service & Consult GmbH | — | X | — |
| UNS | — | — | Must | — |
0081 D00460 | Separation of header and detail section | — | X | — |
| SG5.NAD | — | — | Must | — |
3035 DP00470 | Supply address | — | X | — |
| SG6.LOC | — | — | Must | — |
3227 17200480 | Reporting point | — | X | — |
322500490 | Designation | — | X | ([951] [510] ∧ ([522] ∨ [524])) ⊻ ([950] [514] ∧ ([151] ⊻ [152] ∧ (([523] ∨ [525])))) |
| SG9.LIN | — | — | Must | — |
108200500 | Line item number | — | X | [908] |
| SG9.PIA | — | — | Must | — |
4347 500510 | Product identification | — | X | — |
714000520 | Medium / OBIS code number | — | X | ([152] ∧ [51] ∧ [501]) ⊻ ([151] ∧ [501]) |
7143 SRW00530 | OBIS code | — | X | — |
| SG10.QTY | — | — | Must | — |
6063 22000540 | True value | — | X | — |
6063 6700550 | Substitute value | — | X | ([152] ∧ [32] ∧ ([33] ∨ [36] ∨ [42])) ⊻ [151] |
6063 20100560 | Proposed value | — | X | ([152] ∧ [35] ∧ ([33] ∨ [36]) ∧ [12]) |
6063 2000570 | Unusable value | — | X | ([152] ∧ [35] ∧ ([33] ∨ [36])) |
6063 18700580 | Forecast value | — | X | [152] ∧ [32] ∧ [33] ∧ [11] |
606000590 | Quantity | — | X | (([902] ∧ [937] [46] ∧ [573]) ∨ ([902] ∧ [907] [48] ∧ [62]) ∨ ([910] ∧ [906] [62]) [152]) ⊻ ([902] ∧ [906] ∧ [151]) |
| SG10.DTM | — | — | Must | [152] ⊻ ([151] ∧ [153]) |
2005 16300600 | Processing, start date/time | — | X | — |
238000610 | Date or time or time span, value | — | X | ((([UB2] ∧ [119]) ⊻ ([931] [38])) ∧ [495]) |
2379 30300620 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | [152] ⊻ ([151] ∧ [153]) |
2005 16400630 | Processing, end date/time | — | X | — |
238000640 | Date or time or time span, value | — | X | ((([UB2] ∧ [119]) ⊻ ([931] [38])) ∧ [495]) |
2379 30300650 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | [151] ∧ [154] |
2005 30600660 | Demand period | — | X | — |
238000670 | Date or time or time span, value | — | X | — |
2379 61000680 | CCYYMM | — | X | — |
| SG10.STS | — | — | Should | ([92] ⊻ [93] ⊻ [94]) ∧ [126] ∧ [152] |
9015 Z3300690 | Plausibility check note | — | X | — |
9013 Z8300700 | Customer self-reading | — | X | [5P0..1] |
9013 Z8400710 | Vacancy | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 Z8500720 | Actual meter overflow checked | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 Z8600730 | Plausible due to check reading | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 Z8700740 | Plausible due to customer information | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 ZC300750 | Exchange of the substitute value | — | X | [5P0..1] |
9013 ZR500760 | Calculated value | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
| SG10.STS | — | — | Must | [152] ∧ ([92] ⊻ [94]) |
9015 Z3200770 | Substitute value formation procedure | — | X | — |
9013 Z8900780 | Comparative measurement (not calibrated) | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9000790 | Meter reading value simulation from calibrated values | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9100800 | Meter reading value simulation from non-calibrated values | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9200810 | Interpolation | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9300820 | Hold value | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9400830 | Balancing grid section | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9500840 | Historical meter reading values | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZQ800850 | Distribution | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZQ900860 | Use of values from the fault quantity register | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZR000870 | Bypass and correction quantities | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZS000880 | Substitute value procedure according to the details at the level of the metering location | — | X | [46] ∧ [568] |
| SG10.STS | — | — | Should | [127] ∧ [559] ∧ [152] |
9015 Z3400890 | Reason for correction | — | X | — |
9013 Z7400900 | no access | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z7500910 | Communication fault | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z7600920 | Grid outage | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z7800930 | Device replacement | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z8000940 | Device operates outside the operating conditions | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z8100950 | Measuring equipment faulty/defective | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z8200960 | Measurement uncertainty | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z9800970 | Consideration of the fault quantity register | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9900980 | Volume conversion incomplete | — | X | [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA000990 | Time set /synchronisation | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA101000 | Meter reading value implausible | — | X | [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA401010 | Incorrect reading | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA501020 | Change of the calculation | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA601030 | Conversion of the metering location | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA701040 | Data processing error | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA801050 | Calorific value correction | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA901060 | Z-number correction | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZB001070 | Fault / defect of measuring equipment | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZC401080 | Pulse value not sufficient | — | X | [4P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZJ901090 | Energy quantity from the unpaired time interval | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZR101100 | Maintenance work on a calibrated measuring device | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR201110 | faulty values | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR301120 | Maintenance work on measuring devices compliant with calibration law | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR401130 | Consistency and synchronisation check | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
| SG10.STS | — | — | Must | [92] ∧ [152] |
9015 Z4001140 | Reason for substitute value formation | — | X | — |
9013 Z7401150 | no access | — | X | [4P0..1] |
9013 Z7501160 | Communication fault | — | X | [4P0..1] |
9013 Z7601170 | Grid outage | — | X | [4P0..1] |
9013 Z7801180 | Device replacement | — | X | [4P0..1] |
9013 Z8001190 | Device operates outside the operating conditions | — | X | [4P0..1] |
9013 Z8101200 | Measuring equipment faulty/defective | — | X | [4P0..1] |
9013 Z8201210 | Measurement uncertainty | — | X | [4P0..1] |
9013 Z9801220 | Consideration of the fault quantity register | — | X | [4P0..1] |
9013 Z9901230 | Volume conversion incomplete | — | X | [4P0..1] |
9013 ZA001240 | Time set /synchronisation | — | X | [4P0..1] |
9013 ZA101250 | Meter reading value implausible | — | X | [4P0..1] |
9013 ZA401260 | Incorrect reading | — | X | [4P0..1] |
9013 ZA501270 | Change of the calculation | — | X | [4P0..1] |
9013 ZA601280 | Conversion of the metering location | — | X | [4P0..1] |
9013 ZA701290 | Data processing error | — | X | [4P0..1] |
9013 ZB001300 | Fault / defect of measuring equipment | — | X | [4P0..1] |
9013 ZC401310 | Pulse value not sufficient | — | X | [4P0..1] |
9013 ZR101320 | Maintenance work on a calibrated measuring device | — | X | [4P0..1] |
9013 ZR201330 | faulty values | — | X | [4P0..1] |
9013 ZR301340 | Maintenance work on measuring devices compliant with calibration law | — | X | [4P0..1] |
9013 ZR401350 | Consistency and synchronisation check | — | X | [4P0..1] |
9013 ZS901360 | Reason for substitute value formation according to the information at metering location level | — | X | [46] ∧ [570] |
| SG10.STS | — | — | Should | [97] ∧ [152] |
9015 Z3101370 | Gas quality | — | X | — |
9013 ZG301380 | Change of gas quality | — | X | — |
| UNT | — | — | Must | — |
007401390 | Number of segments in a message | — | X | — |
006201400 | Message reference number | — | X | — |
| UNZ | — | — | Must | — |
003601410 | Interchange counter | — | X | — |
002001420 | Interchange control reference | — | X | — |
Conditions of this table
The free text of the 62 conditions referenced by the rows above. All conditions of the message type are listed in the condition index MSCONS.
| Marker | Condition |
|---|---|
| [11] | If SG9 PIA+5+7-0?:52.0.22/7-0?:54.0.16/7-0?:54.0.20/7-0?:54.0.22 |
| [12] | If not SG9 PIA+5+7-0?:52.0.22/7-0?:54.0.16/7-0?:54.0.20/7-0?:54.0.22 |
| [32] | if MP-ID in SG2 NAD+MS in the role NB |
| [33] | if MP-ID in SG2 NAD+MR in the role LF |
| [35] | if MP-ID in SG2 NAD+MS in the role MSB |
| [36] | if MP-ID in SG2 NAD+MR in the role NB |
| [38] | if the ID of the metering location is stated in SG6 LOC+172 DE3225 |
| [42] | If MP-ID in SG2 NAD+MR in the role MSB |
| [46] | If the value in SG6 LOC+172 DE3225 has exactly 11 digits |
| [48] | If SG9 PIA+5+7-0?:52.0.22 |
| [51] | If SG9 PIA+5+7-0?:33.86.0 is present, SG9 PIA+5+7-0?:52.0.22/7-0?:54.0.16/7-0?:54.0.20/7-0?:54.0.22 must no longer be specified by repeating SG9 LIN in the same message |
| [62] | If the value in SG6 LOC+172 DE3225 has exactly 33 digits |
| [92] | If SG10 QTY DE6063 with value 67 is present |
| [93] | If SG10 QTY DE6063 with value 220 is present |
| [94] | If SG10 QTY DE6063 with value 201 is present |
| [97] | If this concerns the transmission of a value due to the change of the gas quality |
| [118] | Only MP-ID from the gas division |
| [119] | if the ID of the market location is stated in SG6 LOC+172 DE3225 |
| [126] | if plausibility check notices exist |
| [127] | if a correction reason has to be stated |
| [142] | if the code EM is present in DE3155 in the same COM |
| [143] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [151] | If BGM+Z27 (transaction data in the calendar year before start of supply) present. |
| [152] | If BGM+7 (process data report) present. |
| [153] | If SG9 PIA+5+7-0?:33.86.0 is present |
| [154] | If SG9 PIA+5+7-0?:33.47.0 is present |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [501] | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| [509] | Note: If this is a correction energy quantity, the reference to the MSCONS in which the meter reading was transmitted in advance must be specified here. |
| [510] | Note: Use of the ID of the metering location |
| [514] | Note: Use of the ID of the market location |
| [522] | Note: Only for the transmission of the correction energy quantities in the time interval between two metered values. |
| [523] | Note: Only for the transmission of the energy quantity in the time interval between two metered values before the grid usage settlement. |
| [524] | Note: Only if it concerns the transmission of the billing calorific value and Z number for the period requested by the supplier via a business data request. |
| [525] | Note: Only for the transmission of the energy quantity in the time interval for a market location without a metering location (flat-rate installation) if one of the events from chapter 4.2 has occurred. |
| [529] | Note: Value from BGM+7 DE1004 of the ORDERS with which the request for meter reading values was made. |
| [531] | Note: Value from BGM+7 DE1004 of the MSCONS with which the meter reading was transmitted. |
| [559] | Note: A correction reason is to be specified if: 1. a preliminary value already transmitted to the MP is replaced by a substitute value after cancellation, or 2. a substitute value already transmitted to the MP is replaced by a substitute value after cancellation, or 3. a true value already transmitted to the MP is replaced by a substitute value after cancellation, or 4. a true value already transmitted to the MP is replaced by a true value after cancellation. |
| [568] | Note: Use is permitted only if it is a 1:n relationship between market and metering location and different substitute value determination procedures have been used and communicated at the level of the metering location. |
| [570] | Note: Use is permitted only if it is a 1:n relationship between market and metering location and different reasons for the substitute value determination exist at the level of the metering location and have been communicated. |
| [573] | Note: An energy quantity in the gas division is to be rounded to whole kilowatt hours in accordance with DVGW G685 worksheet 4 chapter 5.3. |
| [576] | Note: Only one piece of information may be transmitted in DE3148 |
| [902] | Format: Possible value: ≥ 0 |
| [906] | Format: max. 3 decimal places |
| [907] | Format: max. 4 decimal places |
| [908] | Format: possible values: 1 to n |
| [910] | Format: Possible value: < 0 or ≥ 0 |
| [918] | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment |
| [UB2] | ([931] ∧ [934] [490]) ⊻ ([931] ∧ [935] [491]) |
| [5P0..1] | [93] If SG10 QTY DE6063 with value 220 present |
| [4P0..1] | [92] If SG10 QTY DE6063 with value 67 present |
| [6P0..1] | [94] If SG10 QTY DE6063 with value 201 present |
| [7P0..1] | [95] If SG10 QTY DE6063 with value 20 present |
| [8P0..1] | [96] If SG10 QTY DE6063 with value Z18 present |
Example message
Example 1
UNA:+.? '
UNB+UNOC:3+9870013800007:502+9800044300007:502+{{date}}:{{time}}+165425++EM'
UNH+434072+MSCONS:D:04B:UN:2.4c'
BGM+7+34072BGM+9'
DTM+137:202307310939?+00:303'
RFF+AGI:12345678910'
RFF+Z13:13009'
NAD+MS+9870013800007::332'
CTA+IC+:Max Mustermann'
COM+?+012345678910:TE'
NAD+MR+9800044300007::332'
UNS+D'
NAD+DP'
LOC+172+50074561188'
LIN+1'
PIA+5+7-0?:33.86.0:SRW'
QTY+220:1000'
DTM+163:202306010400?+00:303'
DTM+164:202307010400?+00:303'
UNT+18+434072'
UNZ+1+165425'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"ENERGIEMENGE": [1 item
{5 fields
"energieverbrauch": [1 item
{6 fields
"transaktionsdaten": {12 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"rufnummern": [1 item
{2 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 2
UNA:+.? '
UNB+UNOC:3+9870006600000:502+9800009600004:502+{{date}}:{{time}}+MRMAMNBB++EM'
UNH+MR6SSUIG+MSCONS:D:04B:UN:2.4c'
BGM+Z27+MQWHBJV2+9'
DTM+137:202606240949?+00:303'
RFF+Z13:13009'
NAD+MS+9870006600000::332'
NAD+MR+9800009600004::332'
UNS+D'
NAD+DP'
LOC+172+50074561188'
LIN+1'
PIA+5+7-0?:33.47.0:SRW'
QTY+220:500'
DTM+306:202603:610'
STS+Z33++Z83'
UNT+15+MR6SSUIG'
UNZ+1+MRMAMNBB'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"ENERGIEMENGE": [1 item
{5 fields
"energieverbrauch": [1 item
{6 fields
"statuszusatzinformationen": [1 item
{2 fields
"transaktionsdaten": {11 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Energy quantity (gas) |
| AHB | MSCONS AHB |
| Response to check identifier | 17102 |
| Transmission channel | AS4 |
This check identifier is used in 19 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM gas | Ch. B 5.1.3 No. 7 | MSBN → NB | Transmission of final reading values by MSBN or MSBA |
| WiM gas | Ch. B 5.1.3 No. 7 | MSBA → NB | Transmission of final reading values by MSBN or MSBA |
| GeLi Gas 2.0 | Request and provision of meter reading values | MSB → NB | Meter reading transmission |
| GeLi Gas 2.0 | Request and provision of meter reading values | NB → MSB | Transmission of substitute values |
| GeLi Gas 2.0 | Request and provision of meter reading values | NB → LF | Meter reading transmission |
| GeLi Gas 2.0 | Transmission of the energy and demand values measured so far | NB → LF | Energy and demand values measured so far |
| GeLi Gas 2.0 | Periodic/regular meter reading transmission | MSB → NB | Meter reading date for measuring equipment with balancing based on profiles |
| GeLi Gas 2.0 | Periodic/regular meter reading transmission | MSB → NB | Regular reading of measuring equipment with RLM |
| GeLi Gas 2.0 | Periodic/regular meter reading transmission | MSB → NB | End of supply / deregistration request |
| GeLi Gas 2.0 | Off-cycle meter reading transmission | MSB → NB | Interim meter reading |
| GeLi Gas 2.0 | Request for calorific value and conversion factor | NB → LF | Transmission of billing calorific value and conversion factor |
| GeLi Gas 2.0 | Business data request from LF to NB | NB → LF | Response |
| GeLi Gas 2.0 | Billing of grid usage | NB → LF | ongoing meter reading values |
| AWH WiM gas 2.0 | Transmission of values from MSB to NB | MSB → NB | Values |
| GeLi Gas | Ch. D 1.2.4 No. 11 | NB → LF | Meter reading transmission |
| GeLi Gas | Ch. D 1.2.4 No. 7 | MSB → NB | Meter reading transmission |
| GeLi Gas | Ch. D 1.2.4 No. 9 | NB → MSB | Transmission of substitute values |
| GeLi Gas | Ch. D 2.2 No. 2 | NB → LF | Response |
| GeLi Gas | Ch. D 3.2 No. 2 | NB → LF | Response |
Further relationships from format version 202610
Version 202610 also carries this check identifier in contexts that the table of version 202604 does not know; they are included in the list above. Everything else on this page — use case, rulebook and communication direction — comes from the page's own version. Before adopting it into an implementation specification, check whether what is stated applies to 202604.
Transaction and responses
Role of this check identifier: response. Basis: the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 17102 | Request for values | ORDERS | explicit |
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfrageReferenz | SG1.RFF+AGI | dokumentennummer |
RFF+AGI quotes the BGM of the request; the target is its dokumentennummer. Measured: 17102 carries dokumentennummer in BGM+[7|Z28|Z48].
Check identifiers of the same AHB table: No other check identifier of message type MSCONS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 168 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains 2 transactions for this check identifier under the message type mscons. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.