Check identifier 13019 — Energy quantity (Electricity)
Check identifier 13019 · EDIFACT message type MSCONS · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 13019 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| ENERGIEMENGE [ ] * | — | object[] | Must | — |
| konfiguration 00010 | konfiguration | string | X | — |
| lokationsId * 00020 | Unique number of the market location or of the metering location to which the energy quantity belongs | string | X | — |
| energieverbrauch [ ] * | — | object[] | Must | — |
| enddatum * 00030 | enddatum | string (date-time) | X | — |
| messwertstatus * 00040 | The status of a meter reading | Enum Messwertstatus | Must | — |
ABGELESEN | — | — | Must | — |
ERSATZWERT | — | — | Must | — |
VORSCHLAGSWERT | — | — | Must | — |
NICHT_VERWENDBAR | — | — | Must | — |
PROGNOSEWERT | — | — | Must | — |
ENERGIEMENGESUMMIERT | — | — | Must | — |
VOLAEUFIGERWERT | — | — | Must | — |
FEHLT | — | — | Must | — |
ANGABE_FUER_LIEFERSCHEIN | — | — | Must | — |
GRUNDLAGE_POG_ERMITTLUNG | — | — | Must | — |
| obiskennzahl * 00050 | obiskennzahl | string | X | — |
| position * 00060 | position | integer | Must | — |
| startdatum * 00070 | startdatum | string (date-time) | X | — |
| wert * 00080 | wert | number (float) | Must | — |
| statuszusatzinformationen [ ] | — | object[] | May | — |
| art 00090 | Status type | Enum StatusArt | X | — |
PLAUSIBILISIERUNGSHINWEIS | — | — | X | — |
ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
KORREKTURGRUND | — | — | X | — |
GRUND_ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
GASQUALITAET | — | — | X | — |
MESSKLASSIFIZIERUNG | — | — | X | — |
| status 00100 | Status | Enum Status | X | — |
KUNDENSELBSTABLESUNG | — | — | X | — |
LEERSTAND | — | — | X | — |
REALER_ZAEHLERUEBERLAUF_GEPRUEFT | — | — | X | — |
PLAUSIBEL_WG_KONTROLLABLESUNG | — | — | X | — |
PLAUSIBEL_WG_KUNDENHINWEIS | — | — | X | — |
AUSTAUSCH_DES_ERSATZWERTES | — | — | X | — |
RECHENWERT | — | — | X | — |
BASIS_MME | — | — | X | — |
VERGLEICHSMESSUNG_GEEICHT | — | — | X | — |
VERGLEICHSMESSUNG_NICHT_GEEICHT | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_GEEICHTEN_WERTEN | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_NICHT_GEEICHTEN_WERTEN | — | — | X | — |
INTERPOLATION | — | — | X | — |
HALTEWERT | — | — | X | — |
BILANZIERUNG_NETZABSCHNITT | — | — | X | — |
HISTORISCHE_MESSWERTE | — | — | X | — |
STATISTISCHE_METHODE | — | — | X | — |
AUFTEILUNG | — | — | X | — |
VERWENDUNG_VON_WERTEN_DES_STOERMENGENZAEHLWERKS | — | — | X | — |
UMGANGS_UND_KORREKTURMENGEN | — | — | X | — |
ANGABEN_MESSLOKATION | — | — | X | — |
KEIN_ZUGANG | — | — | X | — |
KOMMUNIKATIONSSTOERUNG | — | — | X | — |
NETZAUSFALL | — | — | X | — |
SPANNUNGSAUSFALL | — | — | X | — |
STATUS_GERAETEWECHSEL | — | — | X | — |
KALIBRIERUNG | — | — | X | — |
GERAET_ARBEITET_AUSSERHALB_DER_BETRIEBSBEDINGUNGEN | — | — | X | — |
MESSEINRICHTUNG_GESTOERT_DEFEKT | — | — | X | — |
UNSICHERHEIT_MESSUNG | — | — | X | — |
BERUECKSICHTIGUNG_STOERMENGENZAEHLWERK | — | — | X | — |
MENGENUMWERTUNG_VOLLSTAENDIG | — | — | X | — |
UHRZEIT_GESTELLT_SYNCHRONISATION | — | — | X | — |
MESSWERT_UNPLAUSIBEL | — | — | X | — |
FALSCHER_WANDLERFAKTOR | — | — | X | — |
FEHLERHAFTE_ABLESUNG | — | — | X | — |
AENDERUNG_DER_BERECHNUNG | — | — | X | — |
UMBAU_DER_MESSLOKATION | — | — | X | — |
DATENBEARBEITUNGSFEHLER | — | — | X | — |
BRENNWERTKORREKTUR | — | — | X | — |
Z_ZAHL_KORREKTUR | — | — | X | — |
STOERUNG_DEFEKT_MESSEINRICHTUNG | — | — | X | — |
AENDERUNG_TARIFSCHALTZEITEN | — | — | X | — |
TARIFSCHALTGERAET_DEFEKT | — | — | X | — |
IMPULSWERTIGKEIT_NICHT_AUSREICHEND | — | — | X | — |
ENERGIEMENGE_IN_UNGEMESSENEM_ZEITINTERVALL | — | — | X | — |
ENERGIEMENGE_AUS_DEM_UNGEPAIRTEN_ZEITINTERVALL | — | — | X | — |
WARTUNGSARBEITEN_AN_GEEICHTEM_MESSGERAET | — | — | X | — |
GESTOERTE_WERTE | — | — | X | — |
WARTUNGSARBEITEN_AN_EICHRECHTSKONFORMEN_MESSGERAETEN | — | — | X | — |
KONSISTENZ_UND_SYNCHRONPRUEFUNG | — | — | X | — |
GRUND_ANGABEN_MESSLOKATION | — | — | X | — |
ANFORDERUNG_IN_DIE_VERGANGENHEIT_ZUM_ANGEFORDERTEN_ZEITPUNKT_LIEGT_KEIN_WERT_VOR | — | — | X | — |
UMSTELLUNG_GASQUALITAET | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
GESCHEITERT | — | — | X | — |
AUSGEBAUT | — | — | X | — |
| transaktionsdaten * | — | object | Must | — |
| anfrageReferenz 00110 | Application number / RFF+AGI | string | X | — |
| dokumentennummer * 00120 | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| kategorie * 00130 | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| nachrichtendatum * 00140 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenfunktion * 00150 | Message function code / BGM | string | Must | — |
| nachrichtenreferenznummer * 00160 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00170 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00180 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00190 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00200 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00210 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 13019 | Condition |
|---|---|---|---|---|
| UNB | — | — | Must | — |
0001 UNOC00010 | UN/ECE character set C | — | X | — |
0002 300020 | Version 3 | — | X | — |
000400030 | MP-ID Sender | — | X | — |
0007 1400040 | GS1 | — | X | — |
0007 50000050 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
001000060 | MP-ID recipient | — | X | — |
0007 1400070 | GS1 | — | X | — |
0007 50000080 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
001700090 | Date of creation | — | X | — |
001900100 | Time of creation | — | X | — |
002000110 | Interchange control reference | — | X | [918] |
0026 EM00120 | Energy quantity | — | X | — |
0035 100130 | Transmission file is a test | — | — | S [155] |
| UNH | — | — | Must | — |
006200140 | Message reference number | — | X | — |
0065 MSCONS00150 | Report on the consumption of measurable services | — | X | — |
0052 D00160 | Draft version | — | X | — |
0054 04B00170 | Edition 2004 - B | — | X | — |
0051 UN00180 | UN/CEFACT | — | X | — |
0057 2.500190 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 700200 | Process data report | — | X | — |
1001 Z4100210 | Delivery note base price / energy price | — | X | [492] ∧ [32] ∧ [33] |
100400220 | Document number | — | X | — |
1225 900230 | Original | — | X | — |
| DTM | — | — | Must | — |
2005 13700240 | Document-/message date/time | — | X | — |
238000250 | Date or time or time span, value | — | X | [931] [494] |
2379 30300260 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 AGI00270 | Application number | — | X | — |
115400280 | Reference number | — | X | ([529] ∨ [553]) ⊻ ([531] ∧ [509]) |
| SG1.RFF | — | — | Must | — |
1153 Z1300290 | Check identifier | — | X | — |
1154 1301900300 | Meter reading value energy quantity (electricity) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00310 | Document-/message sender or sender | — | X | — |
303900320 | MP-ID | — | X | [117] |
3055 900330 | GS1 | — | X | — |
3055 29300340 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00350 | Message recipient | — | X | — |
303900360 | MP-ID | — | X | [117] |
3055 900370 | GS1 | — | X | — |
3055 29300380 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| UNS | — | — | Must | — |
0081 D00390 | Separation of header and detail section | — | X | — |
| SG5.NAD | — | — | Must | — |
3035 DP00400 | Supply address | — | X | — |
| SG6.LOC | — | — | Must | — |
3227 17200410 | Reporting point | — | X | — |
322500420 | Designation | — | — | M [131] ∧ (([951] ∧ [510] ∧ [522]) ⊻ ([950] ∧ [514] ∧ ([523] ∨ [525]))) |
| SG7.RFF | — | — | Must | — |
1153 AGK00430 | Application reference number | — | X | — |
115400440 | Configuration ID | — | X | [567] |
| SG9.LIN | — | — | Must | — |
108200450 | Line item number | — | X | [908] |
| SG9.PIA | — | — | Must | — |
4347 500460 | Product identification | — | X | — |
714000470 | Medium / OBIS code number | — | X | ([68] ∧ [501] ∧ [566]) ⊻ ([90] ∧ [501]) |
7143 SRW00480 | OBIS code | — | X | — |
| SG10.QTY | — | — | Must | — |
6063 22000490 | True value | — | X | [68] |
6063 6700500 | Substitute value | — | X | [68] ∧ ([35] ∨ ([32] ∧ [77])) |
6063 Z3100510 | Entry for the delivery note | — | X | [90] |
606000520 | Quantity | — | X | ([902] ∧ [906] [46]) ∨ ([910] ∧ [906] [62]) ∨ ([910] ∧ [906] [144]) |
| SG10.DTM | — | — | Must | — |
2005 16300530 | Processing, start date/time | — | X | — |
238000540 | Date or time or time span, value | — | X | ((([UB1] ∧ [119]) ⊻ ([931] [38]) ⊻ ([931] [144])) ∧ [495]) |
2379 30300550 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | — |
2005 16400560 | Processing, end date/time | — | X | — |
238000570 | Date or time or time span, value | — | X | ((([UB1] ∧ [119]) ⊻ ([931] [38]) ⊻ ([931] [144])) ∧ [495]) |
2379 30300580 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.STS | — | — | Should | ([92] ⊻ [93]) ∧ [126] |
9015 Z3300590 | Plausibility check note | — | X | — |
9013 Z8300600 | Customer self-reading | — | X | [5P0..1] |
9013 Z8400610 | Vacancy | — | X | [4P0..1] ⊻ [5P0..1] |
9013 Z8500620 | Actual meter overflow checked | — | X | [4P0..1] ⊻ [5P0..1] |
9013 Z8600630 | Plausible due to check reading | — | X | [4P0..1] ⊻ [5P0..1] |
9013 Z8700640 | Plausible due to customer information | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZC300650 | Exchange of the substitute value | — | X | [4P0..1] ⊻ [5P0..1] |
| SG10.STS | — | — | Must | [92] |
9015 Z3200660 | Substitute value formation procedure | — | X | — |
9013 Z8800670 | Comparative measurement (calibrated) | — | X | [4P0..1] |
9013 Z8900680 | Comparative measurement (not calibrated) | — | X | [4P0..1] |
9013 Z9200690 | Interpolation | — | X | [4P0..1] |
9013 ZJ200700 | Statistical method | — | X | [4P0..1] |
9013 ZS000710 | Substitute value procedure according to the details at the level of the metering location | — | X | [46] ∧ [568] |
| SG10.STS | — | — | Should | [127] ∧ [541] |
9015 Z3400720 | Reason for correction | — | X | — |
9013 Z7400730 | no access | — | X | [4P0..1] |
9013 Z7500740 | Communication fault | — | X | [4P0..1] |
9013 Z7600750 | Grid outage | — | X | [4P0..1] |
9013 Z7700760 | Voltage failure | — | X | [4P0..1] |
9013 Z7800770 | Device replacement | — | X | [4P0..1] |
9013 Z7900780 | Calibration | — | X | [4P0..1] |
9013 Z8000790 | Device operates outside the operating conditions | — | X | [4P0..1] |
9013 Z8100800 | Measuring equipment faulty/defective | — | X | [4P0..1] |
9013 Z8200810 | Measurement uncertainty | — | X | [4P0..1] |
9013 ZA000820 | Time set /synchronisation | — | X | [4P0..1] |
9013 ZA100830 | Meter reading value implausible | — | X | [4P0..1] |
9013 ZA300840 | Incorrect transformer factor | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA400850 | Incorrect reading | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA500860 | Change of the calculation | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA600870 | Conversion of the metering location | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA700880 | Data processing error | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZB000890 | Fault / defect of measuring equipment | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZB900900 | Change tariff switching times | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZC200910 | Tariff switching device defective | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZC400920 | Pulse value not sufficient | — | X | [4P0..1] |
9013 ZJ800930 | Energy quantity in unmetered time interval | — | X | [4P0..1] |
9013 ZJ900940 | Energy quantity from the unpaired time interval | — | X | [4P0..1] ⊻ [5P0..1] |
| SG10.STS | — | — | Must | [92] |
9015 Z4000950 | Reason for substitute value formation | — | X | — |
9013 Z7400960 | no access | — | X | [4P0..1] |
9013 Z7500970 | Communication fault | — | X | [4P0..1] |
9013 Z7600980 | Grid outage | — | X | [4P0..1] |
9013 Z7700990 | Voltage failure | — | X | [4P0..1] |
9013 Z7801000 | Device replacement | — | X | [4P0..1] |
9013 Z7901010 | Calibration | — | X | [4P0..1] |
9013 Z8001020 | Device operates outside the operating conditions | — | X | [4P0..1] |
9013 Z8101030 | Measuring equipment faulty/defective | — | X | [4P0..1] |
9013 Z8201040 | Measurement uncertainty | — | X | [4P0..1] |
9013 ZA001050 | Time set /synchronisation | — | X | [4P0..1] |
9013 ZA101060 | Meter reading value implausible | — | X | [4P0..1] |
9013 ZA301070 | Incorrect transformer factor | — | X | [4P0..1] |
9013 ZA401080 | Incorrect reading | — | X | [4P0..1] |
9013 ZA501090 | Change of the calculation | — | X | [4P0..1] |
9013 ZA601100 | Conversion of the metering location | — | X | [4P0..1] |
9013 ZA701110 | Data processing error | — | X | [4P0..1] |
9013 ZB001120 | Fault / defect of measuring equipment | — | X | [4P0..1] |
9013 ZB901130 | Change tariff switching times | — | X | [4P0..1] |
9013 ZC201140 | Tariff switching device defective | — | X | [4P0..1] |
9013 ZC401150 | Pulse value not sufficient | — | X | [4P0..1] |
9013 ZS901160 | Reason for substitute value formation according to the information at metering location level | — | X | [46] ∧ [570] |
| SG10.STS | — | — | Must | [68] ∧ [35] ∧ [46] ∧ [2003] |
9015 1001170 | Metering classification | — | X | — |
4405 Z3601180 | Meter reading at the start of the specified energy quantity available and communicated | — | X | [83] ∨ ([87] ∧ [544]) |
4405 Z3701190 | Meter reading at the end of the specified energy quantity available and communicated | — | X | [84] ∨ ([88] ∧ [545] ∧ [577]) |
4405 Z3801200 | Meter reading at the start of the specified energy quantity not available due to quantity delimitation | — | X | [85] |
4405 Z3901210 | Meter reading at the end of the specified energy quantity not available due to quantity delimitation | — | X | [86] |
| UNT | — | — | Must | — |
007401220 | Number of segments in a message | — | X | — |
006201230 | Message reference number | — | X | — |
| UNZ | — | — | Must | — |
003601240 | Interchange counter | — | X | — |
002001250 | Interchange control reference | — | X | — |
Conditions of this table
The free text of the 57 conditions referenced by the rows above. All conditions of the message type are listed in the condition index MSCONS.
| Marker | Condition |
|---|---|
| [32] | if MP-ID in SG2 NAD+MS in the role NB |
| [33] | if MP-ID in SG2 NAD+MR in the role LF |
| [35] | if MP-ID in SG2 NAD+MS in the role MSB |
| [38] | if the ID of the metering location is stated in SG6 LOC+172 DE3225 |
| [46] | If the value in SG6 LOC+172 DE3225 has exactly 11 digits |
| [62] | If the value in SG6 LOC+172 DE3225 has exactly 33 digits |
| [68] | If BGM+7 present |
| [77] | If MP-ID in SG2 NAD+MR of the RB HKN-R |
| [83] | If in the same SG9 LIN the entry STS+10+Z38 is not present |
| [84] | If in the same SG9 LIN the entry STS+10+Z39 is not present |
| [85] | If in the same SG9 LIN the entry STS+10+Z36 is not present |
| [86] | If in the same SG9 LIN the entry STS+10+Z37 is not present |
| [87] | If the value in DTM+163 DE2380 of the same SG6 LOC+172 with the same value in SG9 PIA+5 DE7140 is the earliest point in time specified |
| [88] | If the value in DTM+164 DE2380 of the same SG6 LOC+172 with the same value in SG9 PIA+5 DE7140 is the latest point in time specified |
| [90] | If BGM+Z41 present |
| [92] | If SG10 QTY DE6063 with value 67 is present |
| [93] | If SG10 QTY DE6063 with value 220 is present |
| [117] | Only MP-ID from the electricity division |
| [119] | if the ID of the market location is stated in SG6 LOC+172 DE3225 |
| [126] | if plausibility check notices exist |
| [127] | if a correction reason has to be stated |
| [131] | if RFF+AGK (configuration ID) is not present |
| [144] | If the value in SG7 RFF+AGK DE1154 (configuration ID) is present |
| [155] | If the transmission file is exchanged for test purposes. |
| [492] | if MP-ID in NAD+MR from division electricity |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [501] | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| [509] | Note: If this is a correction energy quantity, the reference to the MSCONS in which the meter reading was transmitted in advance must be specified here. |
| [510] | Note: Use of the ID of the metering location |
| [514] | Note: Use of the ID of the market location |
| [522] | Note: Only for the transmission of the correction energy quantities in the time interval between two metered values. |
| [523] | Note: Only for the transmission of the energy quantity in the time interval between two metered values before the grid usage settlement. |
| [525] | Note: Only for the transmission of the energy quantity in the time interval for a market location without a metering location (flat-rate installation) if one of the events from chapter 4.2 has occurred. |
| [529] | Note: Value from BGM+7 DE1004 of the ORDERS with which the request for meter reading values was made. |
| [531] | Note: Value from BGM+7 DE1004 of the MSCONS with which the meter reading was transmitted. |
| [541] | Note: A correction reason is to be specified if: 1. a preliminary value already transmitted to the MP is replaced by a substitute value after cancellation, or 2. a substitute value already transmitted to the MP is replaced by a substitute value after cancellation, or 3. a true value already transmitted to the MP is replaced by a substitute value after cancellation, or 4. a true value already transmitted to the MP is replaced by a true value after cancellation. |
| [544] | Note: In the case of a quantity split (e.g. due to a delimitation) for SG6 LOC+172, a meter reading must be available and communicated for every OBIS code for the earliest specified point in time at the start of the time interval (across all repetitions of the LIN segments of the same SG6 LOC+172). |
| [545] | Note: In the case of a quantity split (e.g. due to a delimitation) for SG6 LOC+172, a meter reading must be available and communicated for every OBIS code for the latest specified point in time at the end of the time interval (across all repetitions of the LIN segments of the same SG6 LOC+172). |
| [553] | Note: Value from BGM+Z34 DE1004 of the ORDERS with which the complaint regarding values was made |
| [566] | Note: Only the values that were transmitted by the MSB in the previous master data exchange for this reporting point at the point in time are permitted. |
| [567] | Note: The configuration ID that was communicated in the previous master data exchange must be specified. |
| [568] | Note: Use is permitted only if it is a 1:n relationship between market and metering location and different substitute value determination procedures have been used and communicated at the level of the metering location. |
| [570] | Note: Use is permitted only if it is a 1:n relationship between market and metering location and different reasons for the substitute value determination exist at the level of the metering location and have been communicated. |
| [577] | Note: This code is also to be used if, due to the termination of a metering location (decommissioning), the termination of the market location (decommissioning) takes place at different points in time, that is, the termination of the metering location takes place before the termination of the market location. The energy quantity is to be transmitted up to the end point in time of the market location, even though the last meter reading of the metering location lies at an earlier point in time. |
| [902] | Format: Possible value: ≥ 0 |
| [906] | Format: max. 3 decimal places |
| [908] | Format: possible values: 1 to n |
| [910] | Format: Possible value: < 0 or ≥ 0 |
| [918] | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| [931] | Format: ZZZ = +00 |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [2003] | Segment group must be specified exactly two times per SG9 LIN |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [5P0..1] | [93] If SG10 QTY DE6063 with value 220 present |
| [4P0..1] | [92] If SG10 QTY DE6063 with value 67 present |
Example message
Example 1
UNA:+.? '
UNB+UNOC:3+9904446000007:500+9900321000005:500+{{date}}:{{time}}+177706++EM'
UNH+039126+MSCONS:D:04B:UN:2.5'
BGM+7+039126BGM+9'
DTM+137:202610011100?+00:303'
RFF+AGI:REF12345678910'
RFF+Z13:13019'
NAD+MS+9904446000007::293'
NAD+MR+9900321000005::293'
UNS+D'
NAD+DP'
LOC+172+DE0032106765712000000000000000037'
LIN+1'
PIA+5+1-0?:1.8.0:SRW'
QTY+67:2000'
DTM+163:202412312300?+00:303'
DTM+164:202503152300?+00:303'
STS+Z32++Z92'
STS+Z40++Z74'
UNT+18+039126'
UNZ+1+177706'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"ENERGIEMENGE": [1 item
{5 fields
"energieverbrauch": [1 item
{7 fields
"statuszusatzinformationen": [2 items
{2 fields
{2 fields
"transaktionsdaten": {12 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 2
UNA:+.? '
UNB+UNOC:3+9904446000007:500+9903692000001:500+{{date}}:{{time}}+24100204533914++EM'
UNH+UNHM24CGBL4+MSCONS:D:04B:UN:2.5'
BGM+7+BGMM1WGORGW+9'
DTM+137:202610011100?+00:303'
RFF+AGI:PP172409301012154888888888888563413'
RFF+Z13:13019'
NAD+MS+9904446000007::293'
NAD+MR+9903692000001::293'
UNS+D'
NAD+DP'
LOC+172'
RFF+AGK:34590456ujdfsdghdlktztwqq-053trg'
LIN+1'
PIA+5+1-0?:5.9.0:SRW'
QTY+220:4250.465'
DTM+163:202505012200?+00:303'
DTM+164:202506012200?+00:303'
STS+Z33++Z83'
STS+Z34++ZB0'
UNT+19+UNHM24CGBL4'
UNZ+1+24100204533914'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"ENERGIEMENGE": [1 item
{4 fields
"energieverbrauch": [1 item
{7 fields
"statuszusatzinformationen": [2 items
{2 fields
{2 fields
"transaktionsdaten": {12 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 3
UNA:+.? '
UNB+UNOC:3+9900321000005:500+9903790000002:500+{{date}}:{{time}}+510029++EM'
UNH+621092+MSCONS:D:04B:UN:2.5'
BGM+Z41+621092BGM+9'
DTM+137:202610011100?+00:303'
RFF+Z13:13019'
NAD+MS+9900321000005::293'
NAD+MR+9903790000002::293'
UNS+D'
NAD+DP'
LOC+172+50074561188'
LIN+1'
PIA+5+1-0?:1.9.0:SRW'
QTY+Z31:2000'
DTM+163:202512312300?+00:303'
DTM+164:202603152300?+00:303'
UNT+15+621092'
UNZ+1+510029'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"ENERGIEMENGE": [1 item
{5 fields
"energieverbrauch": [1 item
{6 fields
"transaktionsdaten": {11 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ÜNB.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Energy quantity (electricity) |
| AHB | MSCONS AHB |
| Transmission channel | MP |
This check identifier is used in 7 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.3 No. 5 | NB → RB HKN-R | Response to meter reading values subscription |
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.4 Case 2 No. 4 | NB → RB HKN-R | Response to meter reading values subscription |
| GPKE part 2 | Transmission of the delivery note for the grid usage settlement | NB → LF | Delivery note |
| GPKE part 4 | Business data request | MSB → LF | Response |
| WiM electricity part 2 | Processing and transmission of values from the MSB of the market location | MSB (corresponds to the MSB on the object market location) → NB | Value (market location / metering location) at NB |
| WiM electricity part 2 | Processing and transmission of values from the MSB of the market location | MSB (corresponds to the MSB on the object market location) → LF | Value (market location / metering location) at LF |
| GPKE part 4 | Business data request | MSB → NB | Response |
Transaction and responses
Role of this check identifier: response. Basis: the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 17102 | Request for values | ORDERS | from the step sequence |
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfrageReferenz | SG1.RFF+AGI | dokumentennummer |
RFF+AGI quotes the BGM of the request; the target is its dokumentennummer. Measured: 17102 carries dokumentennummer in BGM+[7|Z28|Z48].
Check identifiers of the same AHB table: No other check identifier of message type MSCONS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 149 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains 3 transactions for this check identifier under the message type mscons. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.