Check identifier 13025 — Load curve market location, tranche
Check identifier 13025 · EDIFACT message type MSCONS · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 13025 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| ENERGIEMENGE [ ] * | — | object[] | Must | — |
| enddatum * 00010 | Specifies the day and time (if available) when the time period ends. | string (date-time) | X | — |
| konfiguration 00020 | konfiguration | string | X | — |
| lokationsId * 00030 | Unique number of the market location or of the metering location to which the energy quantity belongs | string | X | — |
| startdatum * 00040 | Specifies the day and time (if available) when the time period starts. | string (date-time) | X | — |
| energieverbrauch [ ] * | — | object[] | Must | — |
| enddatum * 00050 | enddatum | string (date-time) | X | — |
| messwertstatus * 00060 | The status of a meter reading | Enum Messwertstatus | Must | — |
ABGELESEN | — | — | Must | — |
ERSATZWERT | — | — | Must | — |
VORSCHLAGSWERT | — | — | Must | — |
NICHT_VERWENDBAR | — | — | Must | — |
PROGNOSEWERT | — | — | Must | — |
ENERGIEMENGESUMMIERT | — | — | Must | — |
VOLAEUFIGERWERT | — | — | Must | — |
FEHLT | — | — | Must | — |
ANGABE_FUER_LIEFERSCHEIN | — | — | Must | — |
GRUNDLAGE_POG_ERMITTLUNG | — | — | Must | — |
| obiskennzahl * 00070 | obiskennzahl | string | X | — |
| position * 00080 | position | integer | Must | — |
| startdatum * 00090 | startdatum | string (date-time) | X | — |
| wert * 00100 | wert | number (float) | Must | — |
| statuszusatzinformationen [ ] | — | object[] | May | — |
| art 00110 | Status type | Enum StatusArt | X | — |
PLAUSIBILISIERUNGSHINWEIS | — | — | X | — |
ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
KORREKTURGRUND | — | — | X | — |
GRUND_ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
GASQUALITAET | — | — | X | — |
MESSKLASSIFIZIERUNG | — | — | X | — |
| status 00120 | Status | Enum Status | X | — |
KUNDENSELBSTABLESUNG | — | — | X | — |
LEERSTAND | — | — | X | — |
REALER_ZAEHLERUEBERLAUF_GEPRUEFT | — | — | X | — |
PLAUSIBEL_WG_KONTROLLABLESUNG | — | — | X | — |
PLAUSIBEL_WG_KUNDENHINWEIS | — | — | X | — |
AUSTAUSCH_DES_ERSATZWERTES | — | — | X | — |
RECHENWERT | — | — | X | — |
BASIS_MME | — | — | X | — |
VERGLEICHSMESSUNG_GEEICHT | — | — | X | — |
VERGLEICHSMESSUNG_NICHT_GEEICHT | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_GEEICHTEN_WERTEN | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_NICHT_GEEICHTEN_WERTEN | — | — | X | — |
INTERPOLATION | — | — | X | — |
HALTEWERT | — | — | X | — |
BILANZIERUNG_NETZABSCHNITT | — | — | X | — |
HISTORISCHE_MESSWERTE | — | — | X | — |
STATISTISCHE_METHODE | — | — | X | — |
AUFTEILUNG | — | — | X | — |
VERWENDUNG_VON_WERTEN_DES_STOERMENGENZAEHLWERKS | — | — | X | — |
UMGANGS_UND_KORREKTURMENGEN | — | — | X | — |
ANGABEN_MESSLOKATION | — | — | X | — |
KEIN_ZUGANG | — | — | X | — |
KOMMUNIKATIONSSTOERUNG | — | — | X | — |
NETZAUSFALL | — | — | X | — |
SPANNUNGSAUSFALL | — | — | X | — |
STATUS_GERAETEWECHSEL | — | — | X | — |
KALIBRIERUNG | — | — | X | — |
GERAET_ARBEITET_AUSSERHALB_DER_BETRIEBSBEDINGUNGEN | — | — | X | — |
MESSEINRICHTUNG_GESTOERT_DEFEKT | — | — | X | — |
UNSICHERHEIT_MESSUNG | — | — | X | — |
BERUECKSICHTIGUNG_STOERMENGENZAEHLWERK | — | — | X | — |
MENGENUMWERTUNG_VOLLSTAENDIG | — | — | X | — |
UHRZEIT_GESTELLT_SYNCHRONISATION | — | — | X | — |
MESSWERT_UNPLAUSIBEL | — | — | X | — |
FALSCHER_WANDLERFAKTOR | — | — | X | — |
FEHLERHAFTE_ABLESUNG | — | — | X | — |
AENDERUNG_DER_BERECHNUNG | — | — | X | — |
UMBAU_DER_MESSLOKATION | — | — | X | — |
DATENBEARBEITUNGSFEHLER | — | — | X | — |
BRENNWERTKORREKTUR | — | — | X | — |
Z_ZAHL_KORREKTUR | — | — | X | — |
STOERUNG_DEFEKT_MESSEINRICHTUNG | — | — | X | — |
AENDERUNG_TARIFSCHALTZEITEN | — | — | X | — |
TARIFSCHALTGERAET_DEFEKT | — | — | X | — |
IMPULSWERTIGKEIT_NICHT_AUSREICHEND | — | — | X | — |
ENERGIEMENGE_IN_UNGEMESSENEM_ZEITINTERVALL | — | — | X | — |
ENERGIEMENGE_AUS_DEM_UNGEPAIRTEN_ZEITINTERVALL | — | — | X | — |
WARTUNGSARBEITEN_AN_GEEICHTEM_MESSGERAET | — | — | X | — |
GESTOERTE_WERTE | — | — | X | — |
WARTUNGSARBEITEN_AN_EICHRECHTSKONFORMEN_MESSGERAETEN | — | — | X | — |
KONSISTENZ_UND_SYNCHRONPRUEFUNG | — | — | X | — |
GRUND_ANGABEN_MESSLOKATION | — | — | X | — |
ANFORDERUNG_IN_DIE_VERGANGENHEIT_ZUM_ANGEFORDERTEN_ZEITPUNKT_LIEGT_KEIN_WERT_VOR | — | — | X | — |
UMSTELLUNG_GASQUALITAET | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
GESCHEITERT | — | — | X | — |
AUSGEBAUT | — | — | X | — |
| transaktionsdaten * | — | object | Must | — |
| anfrageReferenz 00130 | Application number / RFF+AGI | string | X | — |
| dokumentennummer * 00140 | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| kategorie * 00150 | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| nachrichtendatum * 00160 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenfunktion * 00170 | Message function code / BGM | string | Must | — |
| nachrichtenreferenznummer * 00180 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00190 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00200 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00210 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00220 | Email address | string | Must | — |
| nachname 00230 | Surname (family name) of the contact person | string | X | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00240 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00250 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00260 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00270 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 13025 | Condition |
|---|---|---|---|---|
| UNB | — | — | Must | — |
0001 UNOC00010 | UN/ECE character set C | — | X | — |
0002 300020 | Version 3 | — | X | — |
000400030 | MP-ID Sender | — | X | — |
0007 1400040 | GS1 | — | X | — |
0007 50000050 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
001000060 | MP-ID recipient | — | X | — |
0007 1400070 | GS1 | — | X | — |
0007 50000080 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
001700090 | Date of creation | — | X | — |
001900100 | Time of creation | — | X | — |
002000110 | Interchange control reference | — | X | [918] |
0026 TL00120 | Load curve, any time period | — | X | — |
| UNH | — | — | Must | — |
006200130 | Message reference number | — | X | — |
0065 MSCONS00140 | Report on the consumption of measurable services | — | X | — |
0052 D00150 | Draft version | — | X | — |
0054 04B00160 | Edition 2004 - B | — | X | — |
0051 UN00170 | UN/CEFACT | — | X | — |
0057 2.4c00180 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z4800190 | Load curve market location, tranche | — | X | — |
100400200 | Document number | — | X | — |
1225 900210 | Original | — | X | — |
| DTM | — | — | Must | — |
2005 13700220 | Document-/message date/time | — | X | — |
238000230 | Date or time or time span, value | — | X | [931] [494] |
2379 30300240 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 AGI00250 | Application number | — | X | — |
115400260 | Reference number | — | X | [529] ∨ [553] |
| SG1.RFF | — | — | Must | — |
1153 Z1300270 | Check identifier | — | X | — |
1154 1302500280 | Load curve market location, tranche | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00290 | Document-/message sender or sender | — | X | — |
303900300 | MP-ID | — | X | [117] |
3055 900310 | GS1 | — | X | — |
3055 29300320 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.CTA | — | — | Must | — |
3139 IC00330 | Information point | — | X | — |
341200340 | Department or contact person | — | X | — |
| SG4.COM | — | — | Must | — |
314800350 | Communication address, identification | — | X | (([939] [142]) ∨ ([940] [143])) ∧ [576] |
3155 TE00360 | Telephone | — | X | [1P0..1] |
3155 EM00370 | — | X | [1P0..1] | |
3155 AJ00380 | further telephone | — | X | [1P0..1] |
3155 AL00390 | Mobile phone | — | X | [1P0..1] |
3155 FX00400 | Fax number | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00410 | Message recipient | — | X | — |
303900420 | MP-ID | — | X | [117] |
3055 900430 | GS1 | — | X | — |
3055 29300440 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| UNS | — | — | Must | — |
0081 D00450 | Separation of header and detail section | — | X | — |
| SG5.NAD | — | — | Must | — |
3035 DP00460 | Supply address | — | X | — |
| SG6.LOC | — | — | Must | — |
3227 17200470 | Reporting point | — | X | — |
322500480 | Designation | — | X | [950] (([514] ∨ [518]) ∧ ([35] ∨ ([32] ∧ [77]))) |
| SG6.DTM | — | — | Must | — |
2005 16300490 | Processing, start date/time | — | X | — |
238000500 | Date or time or time span, value | — | X | [931] |
2379 30300510 | CCYYMMDDHHMMZZZ | — | X | — |
| SG6.DTM | — | — | Must | — |
2005 16400520 | Processing, end date/time | — | X | — |
238000530 | Date or time or time span, value | — | X | [931] |
2379 30300540 | CCYYMMDDHHMMZZZ | — | X | — |
| SG9.LIN | — | — | Must | — |
108200550 | Line item number | — | X | [908] |
| SG9.PIA | — | — | Must | — |
4347 500560 | Product identification | — | X | — |
714000570 | Medium / OBIS code number | — | X | [501] ∧ [566] |
7143 SRW00580 | OBIS code | — | X | — |
| SG10.QTY | — | — | Must | — |
6063 22000590 | True value | — | X | — |
6063 6700600 | Substitute value | — | X | [35] ∨ ([32] ∧ [77]) |
6063 Z1800610 | Preliminary value | — | X | [35] |
606000620 | Quantity | — | X | [902] ∧ [906] |
| SG10.DTM | — | — | Must | — |
2005 16300630 | Processing, start date/time | — | X | — |
238000640 | Date or time or time span, value | — | X | [931] [495] |
2379 30300650 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | — |
2005 16400660 | Processing, end date/time | — | X | — |
238000670 | Date or time or time span, value | — | X | [931] [495] |
2379 30300680 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.STS | — | — | Should | ([92] ⊻ [93]) ∧ [126] |
9015 Z3300690 | Plausibility check note | — | X | — |
9013 Z8300700 | Customer self-reading | — | X | [5P0..1] |
9013 Z8400710 | Vacancy | — | X | [4P0..1] ⊻ [5P0..1] |
9013 Z8500720 | Actual meter overflow checked | — | X | [4P0..1] ⊻ [5P0..1] |
9013 Z8600730 | Plausible due to check reading | — | X | [4P0..1] ⊻ [5P0..1] |
9013 Z8700740 | Plausible due to customer information | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZC300750 | Exchange of the substitute value | — | X | [4P0..1] ⊻ [5P0..1] |
| SG10.STS | — | — | Must | [92] |
9015 Z3200760 | Substitute value formation procedure | — | X | — |
9013 Z8800770 | Comparative measurement (calibrated) | — | X | [4P0..1] |
9013 Z8900780 | Comparative measurement (not calibrated) | — | X | [4P0..1] |
9013 Z9200790 | Interpolation | — | X | [4P0..1] |
9013 ZJ200800 | Statistical method | — | X | [4P0..1] |
9013 ZS000810 | Substitute value procedure according to the details at the level of the metering location | — | X | [46] ∧ [568] |
| SG10.STS | — | — | Should | [127] ∧ [551] |
9015 Z3400820 | Reason for correction | — | X | — |
9013 Z7400830 | no access | — | X | [4P0..1] |
9013 Z7500840 | Communication fault | — | X | [4P0..1] |
9013 Z7600850 | Grid outage | — | X | [4P0..1] |
9013 Z7700860 | Voltage failure | — | X | [4P0..1] |
9013 Z7800870 | Device replacement | — | X | [4P0..1] |
9013 Z7900880 | Calibration | — | X | [4P0..1] |
9013 Z8000890 | Device operates outside the operating conditions | — | X | [4P0..1] |
9013 Z8100900 | Measuring equipment faulty/defective | — | X | [4P0..1] |
9013 Z8200910 | Measurement uncertainty | — | X | [4P0..1] |
9013 ZA000920 | Time set /synchronisation | — | X | [4P0..1] |
9013 ZA100930 | Meter reading value implausible | — | X | [4P0..1] |
9013 ZA300940 | Incorrect transformer factor | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA400950 | Incorrect reading | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA500960 | Change of the calculation | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA600970 | Conversion of the metering location | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA700980 | Data processing error | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZB000990 | Fault / defect of measuring equipment | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZB901000 | Change tariff switching times | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZC201010 | Tariff switching device defective | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZC401020 | Pulse value not sufficient | — | X | [4P0..1] |
| SG10.STS | — | — | Must | [92] |
9015 Z4001030 | Reason for substitute value formation | — | X | — |
9013 Z7401040 | no access | — | X | [4P0..1] |
9013 Z7501050 | Communication fault | — | X | [4P0..1] |
9013 Z7601060 | Grid outage | — | X | [4P0..1] |
9013 Z7701070 | Voltage failure | — | X | [4P0..1] |
9013 Z7801080 | Device replacement | — | X | [4P0..1] |
9013 Z7901090 | Calibration | — | X | [4P0..1] |
9013 Z8001100 | Device operates outside the operating conditions | — | X | [4P0..1] |
9013 Z8101110 | Measuring equipment faulty/defective | — | X | [4P0..1] |
9013 Z8201120 | Measurement uncertainty | — | X | [4P0..1] |
9013 ZA001130 | Time set /synchronisation | — | X | [4P0..1] |
9013 ZA101140 | Meter reading value implausible | — | X | [4P0..1] |
9013 ZA301150 | Incorrect transformer factor | — | X | [4P0..1] |
9013 ZA401160 | Incorrect reading | — | X | [4P0..1] |
9013 ZA501170 | Change of the calculation | — | X | [4P0..1] |
9013 ZA601180 | Conversion of the metering location | — | X | [4P0..1] |
9013 ZA701190 | Data processing error | — | X | [4P0..1] |
9013 ZB001200 | Fault / defect of measuring equipment | — | X | [4P0..1] |
9013 ZB901210 | Change tariff switching times | — | X | [4P0..1] |
9013 ZC201220 | Tariff switching device defective | — | X | [4P0..1] |
9013 ZC401230 | Pulse value not sufficient | — | X | [4P0..1] |
9013 ZS901240 | Reason for substitute value formation according to the information at metering location level | — | X | [46] ∧ [570] |
| UNT | — | — | Must | — |
007401250 | Number of segments in a message | — | X | — |
006201260 | Message reference number | — | X | — |
| UNZ | — | — | Must | — |
003601270 | Interchange counter | — | X | — |
002001280 | Interchange control reference | — | X | — |
Conditions of this table
The free text of the 34 conditions referenced by the rows above. All conditions of the message type are listed in the condition index MSCONS.
| Marker | Condition |
|---|---|
| [32] | if MP-ID in SG2 NAD+MS in the role NB |
| [35] | if MP-ID in SG2 NAD+MS in the role MSB |
| [46] | If the value in SG6 LOC+172 DE3225 has exactly 11 digits |
| [77] | If MP-ID in SG2 NAD+MR of the RB HKN-R |
| [92] | If SG10 QTY DE6063 with value 67 is present |
| [93] | If SG10 QTY DE6063 with value 220 is present |
| [117] | Only MP-ID from the electricity division |
| [126] | if plausibility check notices exist |
| [127] | if a correction reason has to be stated |
| [142] | if the code EM is present in DE3155 in the same COM |
| [143] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [501] | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| [514] | Note: Use of the ID of the market location |
| [518] | Note: Use of the ID of the tranche |
| [529] | Note: Value from BGM+7 DE1004 of the ORDERS with which the request for meter reading values was made. |
| [551] | Note: A correction reason is to be specified if: 1. a preliminary value already transmitted to the MP is replaced by a substitute value, or 2. a substitute value already transmitted to the MP is replaced by a substitute value, or 3. a true value already transmitted to the MP is replaced by a substitute value, or 4. a true value already transmitted to the MP is replaced by a true value. |
| [553] | Note: Value from BGM+Z34 DE1004 of the ORDERS with which the complaint regarding values was made |
| [566] | Note: Only the values that were transmitted by the MSB in the previous master data exchange for this reporting point at the point in time are permitted. |
| [568] | Note: Use is permitted only if it is a 1:n relationship between market and metering location and different substitute value determination procedures have been used and communicated at the level of the metering location. |
| [570] | Note: Use is permitted only if it is a 1:n relationship between market and metering location and different reasons for the substitute value determination exist at the level of the metering location and have been communicated. |
| [576] | Note: Only one piece of information may be transmitted in DE3148 |
| [902] | Format: Possible value: ≥ 0 |
| [906] | Format: max. 3 decimal places |
| [908] | Format: possible values: 1 to n |
| [918] | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment |
| [5P0..1] | [93] If SG10 QTY DE6063 with value 220 present |
| [4P0..1] | [92] If SG10 QTY DE6063 with value 67 present |
Example message
UNA:+.? '
UNB+UNOC:3+9904545000007:500+9911694000002:500+{{date}}:{{time}}+K21E0D864ED9++TL'
UNH+1+MSCONS:D:04B:UN:2.4c'
BGM+Z48+K21E0D864ED90+9'
DTM+137:202404030553?+00:303'
RFF+Z13:13025'
NAD+MS+9904545000007::293'
NAD+MR+9911694000002::293'
UNS+D'
NAD+DP'
LOC+172+51580175011'
DTM+163:202310052200?+00:303'
DTM+164:202310062200?+00:303'
LIN+1'
PIA+5+1-1?:3.29.0:SRW'
QTY+220:0'
DTM+163:202310052200?+00:303'
DTM+164:202310052215?+00:303'
QTY+220:0'
DTM+163:202310052215?+00:303'
DTM+164:202310052230?+00:303'
QTY+220:0'
DTM+163:202310052230?+00:303'
DTM+164:202310052245?+00:303'
QTY+220:0'
DTM+163:202310052245?+00:303'
DTM+164:202310052300?+00:303'
QTY+220:0'
DTM+163:202310052300?+00:303'
DTM+164:202310052315?+00:303'
QTY+220:0'
DTM+163:202310052315?+00:303'
DTM+164:202310052330?+00:303'
QTY+220:0'
DTM+163:202310052330?+00:303'
DTM+164:202310052345?+00:303'
QTY+220:0'
DTM+163:202310052345?+00:303'
DTM+164:202310060000?+00:303'
QTY+220:0'
DTM+163:202310060000?+00:303'
DTM+164:202310060015?+00:303'
QTY+220:0'
DTM+163:202310060015?+00:303'
DTM+164:202310060030?+00:303'
QTY+220:0'
DTM+163:202310060030?+00:303'
DTM+164:202310060045?+00:303'
QTY+220:0'
DTM+163:202310060045?+00:303'
DTM+164:202310060100?+00:303'
QTY+220:0'
DTM+163:202310060100?+00:303'
DTM+164:202310060115?+00:303'
QTY+220:0'
DTM+163:202310060115?+00:303'
DTM+164:202310060130?+00:303'
QTY+220:0'
DTM+163:202310060130?+00:303'
DTM+164:202310060145?+00:303'
QTY+220:0'
DTM+163:202310060145?+00:303'
DTM+164:202310060200?+00:303'
QTY+220:0'
DTM+163:202310060200?+00:303'
DTM+164:202310060215?+00:303'
QTY+220:0'
DTM+163:202310060215?+00:303'
DTM+164:202310060230?+00:303'
QTY+220:0'
DTM+163:202310060230?+00:303'
DTM+164:202310060245?+00:303'
QTY+220:0'
DTM+163:202310060245?+00:303'
DTM+164:202310060300?+00:303'
QTY+220:0'
DTM+163:202310060300?+00:303'
DTM+164:202310060315?+00:303'
QTY+220:0'
DTM+163:202310060315?+00:303'
DTM+164:202310060330?+00:303'
QTY+220:0'
DTM+163:202310060330?+00:303'
DTM+164:202310060345?+00:303'
QTY+220:0'
DTM+163:202310060345?+00:303'
DTM+164:202310060400?+00:303'
QTY+220:0'
DTM+163:202310060400?+00:303'
DTM+164:202310060415?+00:303'
QTY+220:0'
DTM+163:202310060415?+00:303'
DTM+164:202310060430?+00:303'
QTY+220:0.012'
DTM+163:202310060430?+00:303'
DTM+164:202310060445?+00:303'
QTY+220:0'
DTM+163:202310060445?+00:303'
DTM+164:202310060500?+00:303'
QTY+220:0.188'
DTM+163:202310060500?+00:303'
DTM+164:202310060515?+00:303'
QTY+220:0.388'
DTM+163:202310060515?+00:303'
DTM+164:202310060530?+00:303'
QTY+220:0'
DTM+163:202310060530?+00:303'
DTM+164:202310060545?+00:303'
QTY+220:0.075'
DTM+163:202310060545?+00:303'
DTM+164:202310060600?+00:303'
QTY+220:0.012'
DTM+163:202310060600?+00:303'
DTM+164:202310060615?+00:303'
QTY+220:0'
DTM+163:202310060615?+00:303'
DTM+164:202310060630?+00:303'
QTY+220:0'
DTM+163:202310060630?+00:303'
DTM+164:202310060645?+00:303'
QTY+220:0'
DTM+163:202310060645?+00:303'
DTM+164:202310060700?+00:303'
QTY+220:0'
DTM+163:202310060700?+00:303'
DTM+164:202310060715?+00:303'
QTY+220:0.088'
DTM+163:202310060715?+00:303'
DTM+164:202310060730?+00:303'
QTY+220:0.975'
DTM+163:202310060730?+00:303'
DTM+164:202310060745?+00:303'
QTY+220:0.175'
DTM+163:202310060745?+00:303'
DTM+164:202310060800?+00:303'
QTY+220:0.162'
DTM+163:202310060800?+00:303'
DTM+164:202310060815?+00:303'
QTY+220:0'
DTM+163:202310060815?+00:303'
DTM+164:202310060830?+00:303'
QTY+220:0'
DTM+163:202310060830?+00:303'
DTM+164:202310060845?+00:303'
QTY+220:0.088'
DTM+163:202310060845?+00:303'
DTM+164:202310060900?+00:303'
QTY+220:0.175'
DTM+163:202310060900?+00:303'
DTM+164:202310060915?+00:303'
QTY+220:0.3'
DTM+163:202310060915?+00:303'
DTM+164:202310060930?+00:303'
QTY+220:0.225'
DTM+163:202310060930?+00:303'
DTM+164:202310060945?+00:303'
QTY+220:0.375'
DTM+163:202310060945?+00:303'
DTM+164:202310061000?+00:303'
QTY+220:0'
DTM+163:202310061000?+00:303'
DTM+164:202310061015?+00:303'
QTY+220:0'
DTM+163:202310061015?+00:303'
DTM+164:202310061030?+00:303'
QTY+220:0'
DTM+163:202310061030?+00:303'
DTM+164:202310061045?+00:303'
QTY+220:0.012'
DTM+163:202310061045?+00:303'
DTM+164:202310061100?+00:303'
QTY+220:0'
DTM+163:202310061100?+00:303'
DTM+164:202310061115?+00:303'
QTY+220:0'
DTM+163:202310061115?+00:303'
DTM+164:202310061130?+00:303'
QTY+220:0'
DTM+163:202310061130?+00:303'
DTM+164:202310061145?+00:303'
QTY+220:0.125'
DTM+163:202310061145?+00:303'
DTM+164:202310061200?+00:303'
QTY+220:0.138'
DTM+163:202310061200?+00:303'
DTM+164:202310061215?+00:303'
QTY+220:0'
DTM+163:202310061215?+00:303'
DTM+164:202310061230?+00:303'
QTY+220:0'
DTM+163:202310061230?+00:303'
DTM+164:202310061245?+00:303'
QTY+220:0'
DTM+163:202310061245?+00:303'
DTM+164:202310061300?+00:303'
QTY+220:0'
DTM+163:202310061300?+00:303'
DTM+164:202310061315?+00:303'
QTY+220:0'
DTM+163:202310061315?+00:303'
DTM+164:202310061330?+00:303'
QTY+220:0'
DTM+163:202310061330?+00:303'
DTM+164:202310061345?+00:303'
QTY+220:0'
DTM+163:202310061345?+00:303'
DTM+164:202310061400?+00:303'
QTY+220:0'
DTM+163:202310061400?+00:303'
DTM+164:202310061415?+00:303'
QTY+220:0'
DTM+163:202310061415?+00:303'
DTM+164:202310061430?+00:303'
QTY+220:0'
DTM+163:202310061430?+00:303'
DTM+164:202310061445?+00:303'
QTY+220:0'
DTM+163:202310061445?+00:303'
DTM+164:202310061500?+00:303'
QTY+220:0'
DTM+163:202310061500?+00:303'
DTM+164:202310061515?+00:303'
QTY+220:0'
DTM+163:202310061515?+00:303'
DTM+164:202310061530?+00:303'
QTY+220:0'
DTM+163:202310061530?+00:303'
DTM+164:202310061545?+00:303'
QTY+220:0'
DTM+163:202310061545?+00:303'
DTM+164:202310061600?+00:303'
QTY+220:0'
DTM+163:202310061600?+00:303'
DTM+164:202310061615?+00:303'
QTY+220:0'
DTM+163:202310061615?+00:303'
DTM+164:202310061630?+00:303'
QTY+220:0'
DTM+163:202310061630?+00:303'
DTM+164:202310061645?+00:303'
QTY+220:0'
DTM+163:202310061645?+00:303'
DTM+164:202310061700?+00:303'
QTY+220:0'
DTM+163:202310061700?+00:303'
DTM+164:202310061715?+00:303'
QTY+220:0'
DTM+163:202310061715?+00:303'
DTM+164:202310061730?+00:303'
QTY+220:0'
DTM+163:202310061730?+00:303'
DTM+164:202310061745?+00:303'
QTY+220:0'
DTM+163:202310061745?+00:303'
DTM+164:202310061800?+00:303'
QTY+220:0'
DTM+163:202310061800?+00:303'
DTM+164:202310061815?+00:303'
QTY+220:0'
DTM+163:202310061815?+00:303'
DTM+164:202310061830?+00:303'
QTY+220:0'
DTM+163:202310061830?+00:303'
DTM+164:202310061845?+00:303'
QTY+220:0'
DTM+163:202310061845?+00:303'
DTM+164:202310061900?+00:303'
QTY+220:0'
DTM+163:202310061900?+00:303'
DTM+164:202310061915?+00:303'
QTY+220:0'
DTM+163:202310061915?+00:303'
DTM+164:202310061930?+00:303'
QTY+220:0'
DTM+163:202310061930?+00:303'
DTM+164:202310061945?+00:303'
QTY+220:0'
DTM+163:202310061945?+00:303'
DTM+164:202310062000?+00:303'
QTY+220:0'
DTM+163:202310062000?+00:303'
DTM+164:202310062015?+00:303'
QTY+220:0'
DTM+163:202310062015?+00:303'
DTM+164:202310062030?+00:303'
QTY+220:0'
DTM+163:202310062030?+00:303'
DTM+164:202310062045?+00:303'
QTY+220:0'
DTM+163:202310062045?+00:303'
DTM+164:202310062100?+00:303'
QTY+220:0'
DTM+163:202310062100?+00:303'
DTM+164:202310062115?+00:303'
QTY+220:0'
DTM+163:202310062115?+00:303'
DTM+164:202310062130?+00:303'
QTY+220:0'
DTM+163:202310062130?+00:303'
DTM+164:202310062145?+00:303'
QTY+220:0'
DTM+163:202310062145?+00:303'
DTM+164:202310062200?+00:303'
LIN+2'
PIA+5+1-1?:1.29.0:SRW'
QTY+220:0.725'
DTM+163:202310052200?+00:303'
DTM+164:202310052215?+00:303'
QTY+220:0.75'
DTM+163:202310052215?+00:303'
DTM+164:202310052230?+00:303'
QTY+220:0.738'
DTM+163:202310052230?+00:303'
DTM+164:202310052245?+00:303'
QTY+220:1.388'
DTM+163:202310052245?+00:303'
DTM+164:202310052300?+00:303'
QTY+220:1.175'
DTM+163:202310052300?+00:303'
DTM+164:202310052315?+00:303'
QTY+220:0.762'
DTM+163:202310052315?+00:303'
DTM+164:202310052330?+00:303'
QTY+220:0.75'
DTM+163:202310052330?+00:303'
DTM+164:202310052345?+00:303'
QTY+220:0.725'
DTM+163:202310052345?+00:303'
DTM+164:202310060000?+00:303'
QTY+220:0.738'
DTM+163:202310060000?+00:303'
DTM+164:202310060015?+00:303'
QTY+220:0.762'
DTM+163:202310060015?+00:303'
DTM+164:202310060030?+00:303'
QTY+220:0.762'
DTM+163:202310060030?+00:303'
DTM+164:202310060045?+00:303'
QTY+220:0.8'
DTM+163:202310060045?+00:303'
DTM+164:202310060100?+00:303'
QTY+220:0.75'
DTM+163:202310060100?+00:303'
DTM+164:202310060115?+00:303'
QTY+220:0.738'
DTM+163:202310060115?+00:303'
DTM+164:202310060130?+00:303'
QTY+220:0.788'
DTM+163:202310060130?+00:303'
DTM+164:202310060145?+00:303'
QTY+220:0.738'
DTM+163:202310060145?+00:303'
DTM+164:202310060200?+00:303'
QTY+220:0.712'
DTM+163:202310060200?+00:303'
DTM+164:202310060215?+00:303'
QTY+220:0.825'
DTM+163:202310060215?+00:303'
DTM+164:202310060230?+00:303'
QTY+220:0.838'
DTM+163:202310060230?+00:303'
DTM+164:202310060245?+00:303'
QTY+220:1.112'
DTM+163:202310060245?+00:303'
DTM+164:202310060300?+00:303'
QTY+220:5.038'
DTM+163:202310060300?+00:303'
DTM+164:202310060315?+00:303'
QTY+220:3.5'
DTM+163:202310060315?+00:303'
DTM+164:202310060330?+00:303'
QTY+220:4.2'
DTM+163:202310060330?+00:303'
DTM+164:202310060345?+00:303'
QTY+220:1.388'
DTM+163:202310060345?+00:303'
DTM+164:202310060400?+00:303'
QTY+220:1.575'
DTM+163:202310060400?+00:303'
DTM+164:202310060415?+00:303'
QTY+220:1.475'
DTM+163:202310060415?+00:303'
DTM+164:202310060430?+00:303'
QTY+220:2.638'
DTM+163:202310060430?+00:303'
DTM+164:202310060445?+00:303'
QTY+220:3.712'
DTM+163:202310060445?+00:303'
DTM+164:202310060500?+00:303'
QTY+220:3.538'
DTM+163:202310060500?+00:303'
DTM+164:202310060515?+00:303'
QTY+220:2.5'
DTM+163:202310060515?+00:303'
DTM+164:202310060530?+00:303'
QTY+220:1.888'
DTM+163:202310060530?+00:303'
DTM+164:202310060545?+00:303'
QTY+220:2.062'
DTM+163:202310060545?+00:303'
DTM+164:202310060600?+00:303'
QTY+220:1.9'
DTM+163:202310060600?+00:303'
DTM+164:202310060615?+00:303'
QTY+220:1.912'
DTM+163:202310060615?+00:303'
DTM+164:202310060630?+00:303'
QTY+220:1.65'
DTM+163:202310060630?+00:303'
DTM+164:202310060645?+00:303'
QTY+220:1.788'
DTM+163:202310060645?+00:303'
DTM+164:202310060700?+00:303'
QTY+220:1.325'
DTM+163:202310060700?+00:303'
DTM+164:202310060715?+00:303'
QTY+220:2.262'
DTM+163:202310060715?+00:303'
DTM+164:202310060730?+00:303'
QTY+220:5.375'
DTM+163:202310060730?+00:303'
DTM+164:202310060745?+00:303'
QTY+220:3.962'
DTM+163:202310060745?+00:303'
DTM+164:202310060800?+00:303'
QTY+220:4.338'
DTM+163:202310060800?+00:303'
DTM+164:202310060815?+00:303'
QTY+220:2.388'
DTM+163:202310060815?+00:303'
DTM+164:202310060830?+00:303'
QTY+220:1.962'
DTM+163:202310060830?+00:303'
DTM+164:202310060845?+00:303'
QTY+220:3.6'
DTM+163:202310060845?+00:303'
DTM+164:202310060900?+00:303'
QTY+220:6.162'
DTM+163:202310060900?+00:303'
DTM+164:202310060915?+00:303'
QTY+220:7.05'
DTM+163:202310060915?+00:303'
DTM+164:202310060930?+00:303'
QTY+220:5.062'
DTM+163:202310060930?+00:303'
DTM+164:202310060945?+00:303'
QTY+220:6.262'
DTM+163:202310060945?+00:303'
DTM+164:202310061000?+00:303'
QTY+220:2.275'
DTM+163:202310061000?+00:303'
DTM+164:202310061015?+00:303'
QTY+220:2.912'
DTM+163:202310061015?+00:303'
DTM+164:202310061030?+00:303'
QTY+220:1.525'
DTM+163:202310061030?+00:303'
DTM+164:202310061045?+00:303'
QTY+220:4.262'
DTM+163:202310061045?+00:303'
DTM+164:202310061100?+00:303'
QTY+220:2.712'
DTM+163:202310061100?+00:303'
DTM+164:202310061115?+00:303'
QTY+220:2.962'
DTM+163:202310061115?+00:303'
DTM+164:202310061130?+00:303'
QTY+220:2.438'
DTM+163:202310061130?+00:303'
DTM+164:202310061145?+00:303'
QTY+220:3.338'
DTM+163:202310061145?+00:303'
DTM+164:202310061200?+00:303'
QTY+220:1.938'
DTM+163:202310061200?+00:303'
DTM+164:202310061215?+00:303'
QTY+220:1.125'
DTM+163:202310061215?+00:303'
DTM+164:202310061230?+00:303'
QTY+220:1.1'
DTM+163:202310061230?+00:303'
DTM+164:202310061245?+00:303'
QTY+220:1.038'
DTM+163:202310061245?+00:303'
DTM+164:202310061300?+00:303'
QTY+220:1.062'
DTM+163:202310061300?+00:303'
DTM+164:202310061315?+00:303'
QTY+220:1.262'
DTM+163:202310061315?+00:303'
DTM+164:202310061330?+00:303'
QTY+220:1.1'
DTM+163:202310061330?+00:303'
DTM+164:202310061345?+00:303'
QTY+220:1.25'
DTM+163:202310061345?+00:303'
DTM+164:202310061400?+00:303'
QTY+220:3.038'
DTM+163:202310061400?+00:303'
DTM+164:202310061415?+00:303'
QTY+220:1.062'
DTM+163:202310061415?+00:303'
DTM+164:202310061430?+00:303'
QTY+220:0.675'
DTM+163:202310061430?+00:303'
DTM+164:202310061445?+00:303'
QTY+220:0.562'
DTM+163:202310061445?+00:303'
DTM+164:202310061500?+00:303'
QTY+220:0.575'
DTM+163:202310061500?+00:303'
DTM+164:202310061515?+00:303'
QTY+220:0.525'
DTM+163:202310061515?+00:303'
DTM+164:202310061530?+00:303'
QTY+220:0.588'
DTM+163:202310061530?+00:303'
DTM+164:202310061545?+00:303'
QTY+220:0.562'
DTM+163:202310061545?+00:303'
DTM+164:202310061600?+00:303'
QTY+220:0.575'
DTM+163:202310061600?+00:303'
DTM+164:202310061615?+00:303'
QTY+220:0.55'
DTM+163:202310061615?+00:303'
DTM+164:202310061630?+00:303'
QTY+220:0.562'
DTM+163:202310061630?+00:303'
DTM+164:202310061645?+00:303'
QTY+220:0.7'
DTM+163:202310061645?+00:303'
DTM+164:202310061700?+00:303'
QTY+220:0.662'
DTM+163:202310061700?+00:303'
DTM+164:202310061715?+00:303'
QTY+220:0.7'
DTM+163:202310061715?+00:303'
DTM+164:202310061730?+00:303'
QTY+220:0.662'
DTM+163:202310061730?+00:303'
DTM+164:202310061745?+00:303'
QTY+220:0.712'
DTM+163:202310061745?+00:303'
DTM+164:202310061800?+00:303'
QTY+220:0.662'
DTM+163:202310061800?+00:303'
DTM+164:202310061815?+00:303'
QTY+220:0.712'
DTM+163:202310061815?+00:303'
DTM+164:202310061830?+00:303'
QTY+220:0.688'
DTM+163:202310061830?+00:303'
DTM+164:202310061845?+00:303'
QTY+220:0.7'
DTM+163:202310061845?+00:303'
DTM+164:202310061900?+00:303'
QTY+220:0.662'
DTM+163:202310061900?+00:303'
DTM+164:202310061915?+00:303'
QTY+220:0.7'
DTM+163:202310061915?+00:303'
DTM+164:202310061930?+00:303'
QTY+220:0.725'
DTM+163:202310061930?+00:303'
DTM+164:202310061945?+00:303'
QTY+220:0.675'
DTM+163:202310061945?+00:303'
DTM+164:202310062000?+00:303'
QTY+220:0.662'
DTM+163:202310062000?+00:303'
DTM+164:202310062015?+00:303'
QTY+220:0.662'
DTM+163:202310062015?+00:303'
DTM+164:202310062030?+00:303'
QTY+220:0.7'
DTM+163:202310062030?+00:303'
DTM+164:202310062045?+00:303'
QTY+220:0.688'
DTM+163:202310062045?+00:303'
DTM+164:202310062100?+00:303'
QTY+220:0.7'
DTM+163:202310062100?+00:303'
DTM+164:202310062115?+00:303'
QTY+220:0.638'
DTM+163:202310062115?+00:303'
DTM+164:202310062130?+00:303'
QTY+220:0.788'
DTM+163:202310062130?+00:303'
DTM+164:202310062145?+00:303'
QTY+220:0.638'
DTM+163:202310062145?+00:303'
DTM+164:202310062200?+00:303'
UNT+592+1'
UNZ+1+K21E0D864ED9'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"ENERGIEMENGE": [1 item
{7 fields
"energieverbrauch": [192 items
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
{6 fields
"transaktionsdaten": {11 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ÜNB.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Load curve market location, tranche |
| AHB | MSCONS AHB |
| Transmission channel | MP |
This check identifier is used in 7 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.3 No. 5 | NB → RB HKN-R | Response to meter reading values subscription |
| Processes for the exchange of information between grid operator and the guarantee of origin register (HKN-R) of the Federal Environment Agency (UBA) | Ch. 2.4 Case 2 No. 4 | NB → RB HKN-R | Response to meter reading values subscription |
| GPKE part 4 | Business data request | MSB → LF | Response |
| WiM electricity part 2 | Processing and transmission of values from the MSB of the market location | MSB (corresponds to the MSB on the object market location) → NB | Value (market location / metering location) at NB |
| WiM electricity part 2 | Processing and transmission of values from the MSB of the market location | MSB (corresponds to the MSB on the object market location) → LF | Value (market location / metering location) at LF |
| WiM electricity part 2 | Processing and transmission of values from the MSB of the market location | MSB (corresponds to the MSB on the object market location) → ÜNB | Value (market location) at ÜNB |
| GPKE part 4 | Business data request | MSB → NB | Response |
Transaction and responses
Role of this check identifier: response. Basis: the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 17102 | Request for values | ORDERS | from the step sequence |
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfrageReferenz | SG1.RFF+AGI | dokumentennummer |
RFF+AGI quotes the BGM of the request; the target is its dokumentennummer. Measured: 17102 carries dokumentennummer in BGM+[7|Z28|Z48].
Check identifiers of the same AHB table: No other check identifier of message type MSCONS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 154 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type mscons. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.