Check identifier 13007 — Gas quality
Check identifier 13007 · EDIFACT message type MSCONS · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 13007 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| ENERGIEMENGE [ ] * | — | object[] | Must | — |
| enddatum * 00010 | Specifies the day and time (if available) when the time period ends. | string (date-time) | X | — |
| fertigstellungsdatum * 00020 | fertigstellungsdatum | string (date-time) | X | — |
| konfiguration 00030 | konfiguration | string | X | — |
| lokationsId * 00040 | Unique number of the market location or of the metering location to which the energy quantity belongs | string | X | — |
| startdatum * 00050 | Specifies the day and time (if available) when the time period starts. | string (date-time) | X | — |
| energieverbrauch [ ] * | — | object[] | Must | — |
| enddatum * 00060 | enddatum | string (date-time) | X | — |
| messwertstatus * 00070 | The status of a meter reading | Enum Messwertstatus | Must | — |
ABGELESEN | — | — | Must | — |
ERSATZWERT | — | — | Must | — |
VORSCHLAGSWERT | — | — | Must | — |
NICHT_VERWENDBAR | — | — | Must | — |
PROGNOSEWERT | — | — | Must | — |
ENERGIEMENGESUMMIERT | — | — | Must | — |
VOLAEUFIGERWERT | — | — | Must | — |
FEHLT | — | — | Must | — |
ANGABE_FUER_LIEFERSCHEIN | — | — | Must | — |
GRUNDLAGE_POG_ERMITTLUNG | — | — | Must | — |
| obiskennzahl * 00080 | obiskennzahl | string | X | — |
| position * 00090 | position | integer | Must | — |
| startdatum * 00100 | startdatum | string (date-time) | X | — |
| wert * 00110 | wert | number (float) | Must | — |
| statuszusatzinformationen [ ] | — | object[] | May | — |
| art 00120 | Status type | Enum StatusArt | X | — |
PLAUSIBILISIERUNGSHINWEIS | — | — | X | — |
ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
KORREKTURGRUND | — | — | X | — |
GRUND_ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
GASQUALITAET | — | — | X | — |
MESSKLASSIFIZIERUNG | — | — | X | — |
| status 00130 | Status | Enum Status | X | — |
KUNDENSELBSTABLESUNG | — | — | X | — |
LEERSTAND | — | — | X | — |
REALER_ZAEHLERUEBERLAUF_GEPRUEFT | — | — | X | — |
PLAUSIBEL_WG_KONTROLLABLESUNG | — | — | X | — |
PLAUSIBEL_WG_KUNDENHINWEIS | — | — | X | — |
AUSTAUSCH_DES_ERSATZWERTES | — | — | X | — |
RECHENWERT | — | — | X | — |
BASIS_MME | — | — | X | — |
VERGLEICHSMESSUNG_GEEICHT | — | — | X | — |
VERGLEICHSMESSUNG_NICHT_GEEICHT | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_GEEICHTEN_WERTEN | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_NICHT_GEEICHTEN_WERTEN | — | — | X | — |
INTERPOLATION | — | — | X | — |
HALTEWERT | — | — | X | — |
BILANZIERUNG_NETZABSCHNITT | — | — | X | — |
HISTORISCHE_MESSWERTE | — | — | X | — |
STATISTISCHE_METHODE | — | — | X | — |
AUFTEILUNG | — | — | X | — |
VERWENDUNG_VON_WERTEN_DES_STOERMENGENZAEHLWERKS | — | — | X | — |
UMGANGS_UND_KORREKTURMENGEN | — | — | X | — |
ANGABEN_MESSLOKATION | — | — | X | — |
KEIN_ZUGANG | — | — | X | — |
KOMMUNIKATIONSSTOERUNG | — | — | X | — |
NETZAUSFALL | — | — | X | — |
SPANNUNGSAUSFALL | — | — | X | — |
STATUS_GERAETEWECHSEL | — | — | X | — |
KALIBRIERUNG | — | — | X | — |
GERAET_ARBEITET_AUSSERHALB_DER_BETRIEBSBEDINGUNGEN | — | — | X | — |
MESSEINRICHTUNG_GESTOERT_DEFEKT | — | — | X | — |
UNSICHERHEIT_MESSUNG | — | — | X | — |
BERUECKSICHTIGUNG_STOERMENGENZAEHLWERK | — | — | X | — |
MENGENUMWERTUNG_VOLLSTAENDIG | — | — | X | — |
UHRZEIT_GESTELLT_SYNCHRONISATION | — | — | X | — |
MESSWERT_UNPLAUSIBEL | — | — | X | — |
FALSCHER_WANDLERFAKTOR | — | — | X | — |
FEHLERHAFTE_ABLESUNG | — | — | X | — |
AENDERUNG_DER_BERECHNUNG | — | — | X | — |
UMBAU_DER_MESSLOKATION | — | — | X | — |
DATENBEARBEITUNGSFEHLER | — | — | X | — |
BRENNWERTKORREKTUR | — | — | X | — |
Z_ZAHL_KORREKTUR | — | — | X | — |
STOERUNG_DEFEKT_MESSEINRICHTUNG | — | — | X | — |
AENDERUNG_TARIFSCHALTZEITEN | — | — | X | — |
TARIFSCHALTGERAET_DEFEKT | — | — | X | — |
IMPULSWERTIGKEIT_NICHT_AUSREICHEND | — | — | X | — |
ENERGIEMENGE_IN_UNGEMESSENEM_ZEITINTERVALL | — | — | X | — |
ENERGIEMENGE_AUS_DEM_UNGEPAIRTEN_ZEITINTERVALL | — | — | X | — |
WARTUNGSARBEITEN_AN_GEEICHTEM_MESSGERAET | — | — | X | — |
GESTOERTE_WERTE | — | — | X | — |
WARTUNGSARBEITEN_AN_EICHRECHTSKONFORMEN_MESSGERAETEN | — | — | X | — |
KONSISTENZ_UND_SYNCHRONPRUEFUNG | — | — | X | — |
GRUND_ANGABEN_MESSLOKATION | — | — | X | — |
ANFORDERUNG_IN_DIE_VERGANGENHEIT_ZUM_ANGEFORDERTEN_ZEITPUNKT_LIEGT_KEIN_WERT_VOR | — | — | X | — |
UMSTELLUNG_GASQUALITAET | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
GESCHEITERT | — | — | X | — |
AUSGEBAUT | — | — | X | — |
| transaktionsdaten * | — | object | Must | — |
| dokumentennummer * 00140 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| kategorie * 00150 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 00160 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenfunktion * 00170 | Message function code / BGM | string | X | — |
| nachrichtenreferenznummer * 00180 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00190 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00200 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00210 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00220 | Email address | string | Must | — |
| nachname 00230 | Surname (family name) of the contact person | string | X | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00240 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00250 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00260 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00270 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 13007 | Condition |
|---|---|---|---|---|
| UNB | — | — | Must | — |
0001 UNOC00010 | UN/ECE character set C | — | X | — |
0002 300020 | Version 3 | — | X | — |
000400030 | MP-ID Sender | — | X | — |
0007 1400040 | GS1 | — | X | — |
0007 50200050 | DE, DVGW Service & Consult GmbH | — | X | — |
001000060 | MP-ID recipient | — | X | — |
0007 1400070 | GS1 | — | X | — |
0007 50200080 | DE, DVGW Service & Consult GmbH | — | X | — |
001700090 | Date of creation | — | X | — |
001900100 | Time of creation | — | X | — |
002000110 | Interchange control reference | — | X | [918] |
0026 TL00120 | Load curve, any time period | — | X | — |
| UNH | — | — | Must | — |
006200130 | Message reference number | — | X | — |
0065 MSCONS00140 | Report on the consumption of measurable services | — | X | — |
0052 D00150 | Draft version | — | X | — |
0054 04B00160 | Edition 2004 - B | — | X | — |
0051 UN00170 | UN/CEFACT | — | X | — |
0057 2.4c00180 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z2100190 | Gas composition data | — | X | — |
100400200 | Document number | — | X | — |
1225 900210 | Original | — | X | — |
| DTM | — | — | Must | — |
2005 13700220 | Document-/message date/time | — | X | — |
238000230 | Date or time or time span, value | — | X | [931] [494] |
2379 30300240 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 Z1300250 | Check identifier | — | X | — |
1154 1300700260 | Gas composition data | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00270 | Document-/message sender or sender | — | X | — |
303900280 | MP-ID | — | X | [118] |
3055 900290 | GS1 | — | X | — |
3055 33200300 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG4.CTA | — | — | Must | — |
3139 IC00310 | Information point | — | X | — |
341200320 | Department or contact person | — | X | — |
| SG4.COM | — | — | Must | — |
314800330 | Communication address, identification | — | X | (([939] [142]) ∨ ([940] [143])) ∧ [576] |
3155 TE00340 | Telephone | — | X | [1P0..1] |
3155 EM00350 | — | X | [1P0..1] | |
3155 AJ00360 | further telephone | — | X | [1P0..1] |
3155 AL00370 | Mobile phone | — | X | [1P0..1] |
3155 FX00380 | Fax number | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00390 | Message recipient | — | X | — |
303900400 | MP-ID | — | X | [118] |
3055 900410 | GS1 | — | X | — |
3055 33200420 | DE, DVGW Service & Consult GmbH | — | X | — |
| UNS | — | — | Must | — |
0081 D00430 | Separation of header and detail section | — | X | — |
| SG5.NAD | — | — | Must | — |
3035 DP00440 | Supply address | — | X | — |
| SG6.LOC | — | — | Must | — |
3227 17200450 | Reporting point | — | X | — |
322500460 | Designation | — | X | ([951] (([32] ∧ [36]) ∨ ([35] ∧ [36])) ∧ [510]) ∨ ([950] ([32] ∧ [33]) ∧ [514]) |
| SG6.DTM | — | — | Must | — |
2005 16300470 | Processing, start date/time | — | X | — |
238000480 | Date or time or time span, value | — | X | [931] |
2379 30300490 | CCYYMMDDHHMMZZZ | — | X | — |
| SG6.DTM | — | — | Must | — |
2005 16400500 | Processing, end date/time | — | X | — |
238000510 | Date or time or time span, value | — | X | [931] |
2379 30300520 | CCYYMMDDHHMMZZZ | — | X | — |
| SG6.DTM | — | — | Must | — |
2005 29300530 | Completion date/time | — | X | — |
238000540 | Date or time or time span, value | — | X | [931] |
2379 30400550 | CCYYMMDDHHMMSSZZZ | — | X | — |
| SG9.LIN | — | — | Must | — |
108200560 | Line item number | — | X | [908] |
| SG9.PIA | — | — | Must | — |
4347 500570 | Product identification | — | X | — |
714000580 | Medium / OBIS code number | — | X | [501] |
7143 SRW00590 | OBIS code | — | X | — |
| SG10.QTY | — | — | Must | — |
6063 22000600 | True value | — | X | — |
6063 6700610 | Substitute value | — | X | ([32] ∧ ([33] ∨ [36])) |
6063 20100620 | Proposed value | — | X | ([32] ∧ ([33] ∨ [36])) ⊻ ([35] ∧ [36]) |
6063 2000630 | Unusable value | — | X | ([32] ∧ [33]) ⊻ ([35] ∧ [36]) |
606000640 | Quantity | — | X | ([902] ∧ [907]) ∨ (([910] ∧ [907]) ([49] ∨ [50])) |
| SG10.DTM | — | — | Must | — |
2005 16300650 | Processing, start date/time | — | X | — |
238000660 | Date or time or time span, value | — | X | [931] [495] |
2379 30300670 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | — |
2005 16400680 | Processing, end date/time | — | X | — |
238000690 | Date or time or time span, value | — | X | [931] [495] |
2379 30300700 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.STS | — | — | Must | [92] ⊻ [94] |
9015 Z3200710 | Substitute value formation procedure | — | X | — |
9013 Z8900720 | Comparative measurement (not calibrated) | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9000730 | Meter reading value simulation from calibrated values | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9100740 | Meter reading value simulation from non-calibrated values | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9200750 | Interpolation | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9300760 | Hold value | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9400770 | Balancing grid section | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9500780 | Historical meter reading values | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZQ800790 | Distribution | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZQ900800 | Use of values from the fault quantity register | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZR000810 | Bypass and correction quantities | — | X | [4P0..1] ⊻ [6P0..1] |
| SG10.STS | — | — | Should | [127] ∧ [560] |
9015 Z3400820 | Reason for correction | — | X | — |
9013 Z7400830 | no access | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z7500840 | Communication fault | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z7600850 | Grid outage | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z7800860 | Device replacement | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z8000870 | Device operates outside the operating conditions | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z8100880 | Measuring equipment faulty/defective | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z8200890 | Measurement uncertainty | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z9800900 | Consideration of the fault quantity register | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9900910 | Volume conversion incomplete | — | X | [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA000920 | Time set /synchronisation | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA100930 | Meter reading value implausible | — | X | [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA400940 | Incorrect reading | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA500950 | Change of the calculation | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA600960 | Conversion of the metering location | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA700970 | Data processing error | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA800980 | Calorific value correction | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA900990 | Z-number correction | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZB001000 | Fault / defect of measuring equipment | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZC401010 | Pulse value not sufficient | — | X | [4P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR101020 | Maintenance work on a calibrated measuring device | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR201030 | faulty values | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR301040 | Maintenance work on measuring devices compliant with calibration law | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR401050 | Consistency and synchronisation check | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
| SG10.STS | — | — | Must | [92] |
9015 Z4001060 | Reason for substitute value formation | — | X | — |
9013 Z7401070 | no access | — | X | [4P0..1] |
9013 Z7501080 | Communication fault | — | X | [4P0..1] |
9013 Z7601090 | Grid outage | — | X | [4P0..1] |
9013 Z7801100 | Device replacement | — | X | [4P0..1] |
9013 Z8001110 | Device operates outside the operating conditions | — | X | [4P0..1] |
9013 Z8101120 | Measuring equipment faulty/defective | — | X | [4P0..1] |
9013 Z8201130 | Measurement uncertainty | — | X | [4P0..1] |
9013 Z9801140 | Consideration of the fault quantity register | — | X | [4P0..1] |
9013 Z9901150 | Volume conversion incomplete | — | X | [4P0..1] |
9013 ZA001160 | Time set /synchronisation | — | X | [4P0..1] |
9013 ZA101170 | Meter reading value implausible | — | X | [4P0..1] |
9013 ZA401180 | Incorrect reading | — | X | [4P0..1] |
9013 ZA501190 | Change of the calculation | — | X | [4P0..1] |
9013 ZA601200 | Conversion of the metering location | — | X | [4P0..1] |
9013 ZA701210 | Data processing error | — | X | [4P0..1] |
9013 ZB001220 | Fault / defect of measuring equipment | — | X | [4P0..1] |
9013 ZC401230 | Pulse value not sufficient | — | X | [4P0..1] |
9013 ZR101240 | Maintenance work on a calibrated measuring device | — | X | [4P0..1] |
9013 ZR201250 | faulty values | — | X | [4P0..1] |
9013 ZR301260 | Maintenance work on measuring devices compliant with calibration law | — | X | [4P0..1] |
9013 ZR401270 | Consistency and synchronisation check | — | X | [4P0..1] |
| SG10.STS | — | — | Should | [97] |
9015 Z3101280 | Gas quality | — | X | — |
9013 ZG301290 | Change of gas quality | — | X | — |
| UNT | — | — | Must | — |
007401300 | Number of segments in a message | — | X | — |
006201310 | Message reference number | — | X | — |
| UNZ | — | — | Must | — |
003601320 | Interchange counter | — | X | — |
002001330 | Interchange control reference | — | X | — |
Conditions of this table
The free text of the 36 conditions referenced by the rows above. All conditions of the message type are listed in the condition index MSCONS.
| Marker | Condition |
|---|---|
| [32] | if MP-ID in SG2 NAD+MS in the role NB |
| [33] | if MP-ID in SG2 NAD+MR in the role LF |
| [35] | if MP-ID in SG2 NAD+MS in the role MSB |
| [36] | if MP-ID in SG2 NAD+MR in the role NB |
| [49] | If SG9 PIA+5+7-b?:70.16.16/7-b?:70.16.20/7-b?:70.16.22 (b=channel: value according to the code list of the OBIS codes and media) is present |
| [50] | If SG9 PIA+5+7-b?:70.18.16/7-b?:70.18.20/7-b?:70.18.22 (b=channel: value according to the code list of the OBIS codes and media) is present |
| [92] | If SG10 QTY DE6063 with value 67 is present |
| [94] | If SG10 QTY DE6063 with value 201 is present |
| [97] | If this concerns the transmission of a value due to the change of the gas quality |
| [118] | Only MP-ID from the gas division |
| [127] | if a correction reason has to be stated |
| [142] | if the code EM is present in DE3155 in the same COM |
| [143] | if the code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [501] | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| [510] | Note: Use of the ID of the metering location |
| [514] | Note: Use of the ID of the market location |
| [560] | Note: A correction reason is to be specified if: 1. a preliminary value already transmitted to the MP is replaced by a substitute value, or 2. a substitute value already transmitted to the MP is replaced by a substitute value, or 3. a true value already transmitted to the MP is replaced by a substitute value, or 4. a true value already transmitted to the MP is replaced by a true value. |
| [576] | Note: Only one piece of information may be transmitted in DE3148 |
| [902] | Format: Possible value: ≥ 0 |
| [907] | Format: max. 4 decimal places |
| [908] | Format: possible values: 1 to n |
| [910] | Format: Possible value: < 0 or ≥ 0 |
| [918] | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment |
| [4P0..1] | [92] If SG10 QTY DE6063 with value 67 present |
| [6P0..1] | [94] If SG10 QTY DE6063 with value 201 present |
| [7P0..1] | [95] If SG10 QTY DE6063 with value 20 present |
| [8P0..1] | [96] If SG10 QTY DE6063 with value Z18 present |
| [5P0..1] | [93] If SG10 QTY DE6063 with value 220 present |
Example message
Example 1
UNA:+.? '
UNB+UNOC:3+9800000000001:502+9870000000002:502+{{date}}:{{time}}+P1001087169647++TL'
UNH+UNHM2L0B3O9+MSCONS:D:04B:UN:2.4c'
BGM+Z21+P1001087165887+9'
DTM+137:202409300853?+00:303'
RFF+Z13:13007'
NAD+MS+9800000000001::332'
NAD+MR+9870000000002::332'
UNS+D'
NAD+DP'
LOC+172+50375312838'
DTM+163:202409290400?+00:303'
DTM+164:202409300400?+00:303'
DTM+293:20240901085330?+00:304'
LIN+1'
PIA+5+7-0?:54.0.16:SRW'
QTY+67:70.563'
DTM+163:202409290400?+00:303'
DTM+164:202409290500?+00:303'
STS+Z32++Z92'
STS+Z40++Z74'
STS+Z31++ZG3'
QTY+220:90'
DTM+163:202409290500?+00:303'
DTM+164:202409290600?+00:303'
STS+Z34++Z74'
UNT+25+UNHM2L0B3O9'
UNZ+1+P1001087169647'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"ENERGIEMENGE": [1 item
{8 fields
"energieverbrauch": [2 items
{7 fields
"statuszusatzinformationen": [3 items
{2 fields
{2 fields
{2 fields
{7 fields
"statuszusatzinformationen": [1 item
{2 fields
"transaktionsdaten": {11 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 2
UNA:+.? '
UNB+UNOC:3+9800000000001:502+9870000000002:502+{{date}}:{{time}}+P1001087169647++TL'
UNH+UNHM2L0B3O9+MSCONS:D:04B:UN:2.4c'
BGM+Z21+P1001087165887+9'
DTM+137:202409300853?+00:303'
RFF+Z13:13007'
NAD+MS+9800000000001::332'
NAD+MR+9870000000002::332'
UNS+D'
NAD+DP'
LOC+172+DE7000872667600000001000000029000'
DTM+163:202409290400?+00:303'
DTM+164:202409300400?+00:303'
DTM+293:20240901085330?+00:304'
LIN+1'
PIA+5+7-0?:54.0.16:SRW'
QTY+220:80.563'
DTM+163:202409290400?+00:303'
DTM+164:202409290500?+00:303'
STS+Z31++ZG3'
QTY+220:90'
DTM+163:202409290500?+00:303'
DTM+164:202409290600?+00:303'
STS+Z31++ZG3'
UNT+23+UNHM2L0B3O9'
UNZ+1+P1001087169647'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"ENERGIEMENGE": [1 item
{8 fields
"energieverbrauch": [2 items
{7 fields
"statuszusatzinformationen": [1 item
{2 fields
{7 fields
"statuszusatzinformationen": [1 item
{2 fields
"transaktionsdaten": {11 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | NB | Transmission of values from the MSB to NB | AWH WiM gas 2.0 | Gas | Step 1 |
| NB | NB | Scheduled/regular meter reading transmission | GeLi Gas 2.0 | Gas | Step 2 |
| MSB | MSB | Transmission of values from the MSB to NB | AWH WiM gas 2.0 | Gas | Step 1 |
| MSB | MSB | Scheduled/regular meter reading transmission | GeLi Gas 2.0 | Gas | Step 2 |
| MSB | MSBA | Device replacement | AWH WiM gas 2.0 | Gas | Step 5 |
| MSB | MSBN | Device replacement | AWH WiM gas 2.0 | Gas | Step 5 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Gas composition |
| AHB | MSCONS AHB |
| Transmission channel | AS4 |
This check identifier is used in 9 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| KoV Leitfaden Marktprozesse Bilanzkreismanagement Gas | Ch. 5.3 | NB → LF | — |
| KoV Leitfaden Marktprozesse Bilanzkreismanagement Gas | Ch. 5.3 | NB → NB | — |
| WiM gas | Ch. B 5.1.3 No. 7 | MSBN → NB | Transmission of final reading values by MSBN or MSBA |
| WiM gas | Ch. B 5.1.3 No. 7 | MSBA → NB | Transmission of final reading values by MSBN or MSBA |
| WiM gas | Ch. B 5.1.3 No. 8 | MSBN → NB | Notification of device replacement, master data and installation meter reading |
| GeLi Gas 2.0 | Periodic/regular meter reading transmission | MSB → NB | Regular reading of measuring equipment with RLM |
| AWH WiM gas 2.0 | Device replacement | MSBN → MSBA | Meter reading and point in time of the device removal |
| AWH WiM gas 2.0 | Transmission of values from MSB to NB | MSB → NB | Values |
| GeLi Gas | Ch. D 1.2.4 No. 7 | MSB → NB | Meter reading transmission |
Further relationships from format version 202610
Version 202610 also carries this check identifier in contexts that the table of version 202604 does not know; they are included in the list above. Everything else on this page — use case, rulebook and communication direction — comes from the page's own version. Before adopting it into an implementation specification, check whether what is stated applies to 202604.
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.
Responses: No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.
Check identifiers of the same AHB table: No other check identifier of message type MSCONS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 159 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains 2 transactions for this check identifier under the message type mscons. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.