Check identifier 13020 — Curtailed energy transfer time series
Check identifier 13020 · EDIFACT message type MSCONS · Format version 202610
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 13020 | Condition |
|---|---|---|---|---|
| UNB | — | — | Must | — |
0001 UNOC00010 | UN/ECE character set C | — | X | — |
0002 300020 | Version 3 | — | X | — |
000400030 | MP-ID Sender | — | X | — |
0007 1400040 | GS1 | — | X | — |
0007 50000050 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
001000060 | MP-ID recipient | — | X | — |
0007 1400070 | GS1 | — | X | — |
0007 50000080 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
001700090 | Date of creation | — | X | — |
001900100 | Time of creation | — | X | — |
002000110 | Interchange control reference | — | X | [918] |
0026 TL00120 | Load curve, any time period | — | X | — |
0035 100130 | Transmission file is a test | — | — | S [155] |
| UNH | — | — | Must | — |
006200140 | Message reference number | — | X | — |
0065 MSCONS00150 | Report on the consumption of measurable services | — | X | — |
0052 D00160 | Draft version | — | X | — |
0054 04B00170 | Edition 2004 - B | — | X | — |
0051 UN00180 | UN/CEFACT | — | X | — |
0057 2.500190 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z4300200 | Redispatch Curtailed energy transfer time series | — | X | — |
1001 Z6900210 | Redispatch daily curtailed energy transfer time series | — | X | — |
100400220 | Document number | — | X | — |
1225 900230 | Original | — | X | — |
| DTM | — | — | Must | — |
2005 13700240 | Document-/message date/time | — | X | — |
238000250 | Date or time or time span, value | — | X | [931] [494] |
2379 30300260 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 Z1300270 | Check identifier | — | X | — |
1154 1302000280 | Redispatch Curtailed energy transfer time series | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00290 | Document-/message sender or sender | — | X | — |
303900300 | MP-ID | — | X | [117] |
3055 900310 | GS1 | — | X | — |
3055 29300320 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00330 | Message recipient | — | X | — |
303900340 | MP-ID | — | X | [117] |
3055 900350 | GS1 | — | X | — |
3055 29300360 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| UNS | — | — | Must | — |
0081 D00370 | Separation of header and detail section | — | X | — |
| SG5.NAD | — | — | Must | — |
3035 Z1500380 | Transfer time series | — | X | — |
| SG6.LOC | — | — | Must | — |
3227 17200390 | Reporting point | — | X | — |
322500400 | Designation | — | X | [951] [511] |
| SG6.DTM | — | — | Must | [150] |
2005 16300410 | Processing, start date/time | — | X | — |
238000420 | Date or time or time span, value | — | X | [931] |
2379 30300430 | CCYYMMDDHHMMZZZ | — | X | — |
| SG6.DTM | — | — | Must | [150] |
2005 16400440 | Processing, end date/time | — | X | — |
238000450 | Date or time or time span, value | — | X | [931] |
2379 30300460 | CCYYMMDDHHMMZZZ | — | X | — |
| SG6.DTM | — | — | Must | [121] |
2005 49200470 | Balancing date, -time, -period | — | X | — |
238000480 | Date or time or time span, value | — | X | — |
2379 61000490 | CCYYMM | — | X | — |
| SG6.DTM | — | — | Must | [121] |
2005 29300500 | Completion date/time | — | X | — |
238000510 | Date or time or time span, value | — | X | [931] |
2379 30400520 | CCYYMMDDHHMMSSZZZ | — | X | — |
| SG9.LIN | — | — | Must | — |
108200530 | Line item number | — | X | [908] |
| SG9.PIA | — | — | Must | — |
4347 500540 | Product identification | — | X | — |
714000550 | Medium / OBIS code number | — | X | [501] |
7143 Z0800560 | Medium | — | X | — |
| SG10.QTY | — | — | Must | — |
6063 7900570 | Energy quantity totalled (total value, balance total) | — | X | — |
606000580 | Quantity | — | X | [910] ∧ [906] |
6411 KWH00590 | Kilowatt hour | — | X | — |
| SG10.DTM | — | — | Must | — |
2005 16300600 | Processing, start date/time | — | X | — |
238000610 | Date or time or time span, value | — | X | [931] [495] |
2379 30300620 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | — |
2005 16400630 | Processing, end date/time | — | X | — |
238000640 | Date or time or time span, value | — | X | [931] [495] |
2379 30300650 | CCYYMMDDHHMMZZZ | — | X | — |
| UNT | — | — | Must | — |
007400660 | Number of segments in a message | — | X | — |
006200670 | Message reference number | — | X | — |
| UNZ | — | — | Must | — |
003600680 | Interchange counter | — | X | — |
002000690 | Interchange control reference | — | X | — |
Conditions of this table
The free text of the 14 conditions referenced by the rows above. All conditions of the message type are listed in the condition index MSCONS.
| Marker | Condition |
|---|---|
| [117] | Only MP-ID from the electricity division |
| [121] | if BGM+Z43 (Redispatch outage energy transfer time series) is present |
| [150] | If BGM+Z69 (Redispatch daily curtailed energy transfer time series) present. |
| [155] | If the transmission file is exchanged for test purposes. |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [501] | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| [511] | Note: Use of the ID of the MaBiS-ZP |
| [906] | Format: max. 3 decimal places |
| [908] | Format: possible values: 1 to n |
| [910] | Format: Possible value: < 0 or ≥ 0 |
| [918] | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| [931] | Format: ZZZ = +00 |
| [951] | Format: Metering point identifier |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB, ÜNB, BIKO and BKV.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Curtailed energy transfer time series |
| AHB | MSCONS AHB |
| Transmission channel | AS4 |
This check identifier is used in 9 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Transmission of the daily curtailed energy transfer time series (AAÜZ) | NB (ANB) → ÜNB | Daily AAÜZ |
| MaBiS | Transmission of the monthly curtailed energy transfer time series (AAÜZ) | NB (ANB) → BIKO | Monthly AAÜZ |
| MaBiS | Transmission of the monthly curtailed energy transfer time series (AAÜZ) | BIKO → BKV (LF) | Forwarding of the monthly AAÜZ |
| MaBiS | Transmission of the monthly curtailed energy transfer time series between ANB and BKV (anfNB) | NB (ANB) → BIKO | Monthly AAÜZ |
| MaBiS | Transmission of the monthly curtailed energy transfer time series between ANB and BKV (anfNB) | BIKO → BKV (of the anfNB) | Forwarding of the monthly AAÜZ |
| MaBiS | Transfer of the curtailed energy from the EEG-BK of the NB to the ÜNB | ÜNB → BIKO | Curtailed energy transfer time series |
| MaBiS | Transfer of the curtailed energy from the EEG-BK of the NB to the ÜNB | BIKO → BKV (ÜNB) | Forwarding of the transfer time series |
| MaBiS | Transfer of the curtailed energy from the EEG-BK of the NB to the ÜNB | BIKO → BKV (NB) | Forwarding of the transfer time series |
| MaBiS | Transfer of the curtailed energy from the EEG-BK of the NB to the ÜNB | BIKO → NB (ANB) | Forwarding of the transfer time series |