Check identifier 13023 — Redispatch 2.0 curtailed energy aggregated time series
Check identifier 13023 · EDIFACT message type MSCONS · Format version 202610
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 13023 | Condition |
|---|---|---|---|---|
| UNB | — | — | Must | — |
0001 UNOC00010 | UN/ECE character set C | — | X | — |
0002 300020 | Version 3 | — | X | — |
000400030 | MP-ID Sender | — | X | — |
0007 1400040 | GS1 | — | X | — |
0007 50000050 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
001000060 | MP-ID recipient | — | X | — |
0007 1400070 | GS1 | — | X | — |
0007 50000080 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
001700090 | Date of creation | — | X | — |
001900100 | Time of creation | — | X | — |
002000110 | Interchange control reference | — | X | [918] |
0026 TL00120 | Load curve, any time period | — | X | — |
0035 100130 | Transmission file is a test | — | — | S [155] |
| UNH | — | — | Must | — |
006200140 | Message reference number | — | X | — |
0065 MSCONS00150 | Report on the consumption of measurable services | — | X | — |
0052 D00160 | Draft version | — | X | — |
0054 04B00170 | Edition 2004 - B | — | X | — |
0051 UN00180 | UN/CEFACT | — | X | — |
0057 2.500190 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z4600200 | Redispatch Curtailed energy sum time series | — | X | — |
100400210 | Document number | — | X | — |
1225 900220 | Original | — | X | — |
| DTM | — | — | Must | — |
2005 13700230 | Document-/message date/time | — | X | — |
238000240 | Date or time or time span, value | — | X | [931] [494] |
2379 30300250 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 Z1300260 | Check identifier | — | X | — |
1154 1302300270 | Redispatch Curtailed energy sum time series | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00280 | Document-/message sender or sender | — | X | — |
303900290 | MP-ID | — | X | [117] |
3055 900300 | GS1 | — | X | — |
3055 29300310 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00320 | Message recipient | — | X | — |
303900330 | MP-ID | — | X | [117] |
3055 900340 | GS1 | — | X | — |
3055 29300350 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| UNS | — | — | Must | — |
0081 D00360 | Separation of header and detail section | — | X | — |
| SG5.NAD | — | — | Must | — |
3035 DP00370 | Supply address | — | X | — |
| SG6.LOC | — | — | Must | — |
3227 17200380 | Reporting point | — | X | — |
322500390 | Designation | — | X | [951] [511] |
| SG6.DTM | — | — | Must | — |
2005 49200400 | Balancing date, -time, -period | — | X | — |
238000410 | Date or time or time span, value | — | X | — |
2379 61000420 | CCYYMM | — | X | — |
| SG6.DTM | — | — | Must | — |
2005 29300430 | Completion date/time | — | X | — |
238000440 | Date or time or time span, value | — | X | [931] |
2379 30400450 | CCYYMMDDHHMMSSZZZ | — | X | — |
| SG9.LIN | — | — | Must | — |
108200460 | Line item number | — | X | [908] |
| SG9.PIA | — | — | Must | — |
4347 500470 | Product identification | — | X | — |
714000480 | Medium / OBIS code number | — | X | [501] |
7143 Z0800490 | Medium | — | X | — |
| SG10.QTY | — | — | Must | — |
6063 7900500 | Energy quantity totalled (total value, balance total) | — | X | — |
606000510 | Quantity | — | X | [910] ∧ [906] |
6411 KWH00520 | Kilowatt hour | — | X | — |
| SG10.DTM | — | — | Must | — |
2005 16300530 | Processing, start date/time | — | X | — |
238000540 | Date or time or time span, value | — | X | [931] [495] |
2379 30300550 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | — |
2005 16400560 | Processing, end date/time | — | X | — |
238000570 | Date or time or time span, value | — | X | [931] [495] |
2379 30300580 | CCYYMMDDHHMMZZZ | — | X | — |
| UNT | — | — | Must | — |
007400590 | Number of segments in a message | — | X | — |
006200600 | Message reference number | — | X | — |
| UNZ | — | — | Must | — |
003600610 | Interchange counter | — | X | — |
002000620 | Interchange control reference | — | X | — |
Conditions of this table
The free text of the 12 conditions referenced by the rows above. All conditions of the message type are listed in the condition index MSCONS.
| Marker | Condition |
|---|---|
| [117] | Only MP-ID from the electricity division |
| [155] | If the transmission file is exchanged for test purposes. |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [501] | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| [511] | Note: Use of the ID of the MaBiS-ZP |
| [906] | Format: max. 3 decimal places |
| [908] | Format: possible values: 1 to n |
| [910] | Format: Possible value: < 0 or ≥ 0 |
| [918] | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| [931] | Format: ZZZ = +00 |
| [951] | Format: Metering point identifier |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF and NB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Transmission of the supplier curtailed energy aggregated time series | MaBiS | Electricity | Step 1 |
| NB | ANB | Transmission of the supplier curtailed energy aggregated time series | MaBiS | Electricity | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Redispatch 2.0 Curtailed energy sum time series |
| AHB | MSCONS AHB |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Transmission of the supplier curtailed energy aggregated time series | NB (ANB) → LF | LF-AASZR |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 81 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.