Check identifier 13009 — Energy quantity (Gas)
Check identifier 13009 · EDIFACT message type MSCONS · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 13009 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| ENERGIEMENGE [ ] * | — | object[] | Must | — |
| konfiguration 00010 | konfiguration | string | X | — |
| lokationsId * 00020 | Unique number of the market location or of the metering location to which the energy quantity belongs | string | X | — |
| energieverbrauch [ ] * | — | object[] | Must | — |
| enddatum 00030 | enddatum | string (date-time) | X | — |
| leistungsperiode 00040 | leistungsperiode | string | X | — |
| messwertstatus * 00050 | The status of a meter reading | Enum Messwertstatus | Must | — |
ABGELESEN | — | — | Must | — |
ERSATZWERT | — | — | Must | — |
VORSCHLAGSWERT | — | — | Must | — |
NICHT_VERWENDBAR | — | — | Must | — |
PROGNOSEWERT | — | — | Must | — |
ENERGIEMENGESUMMIERT | — | — | Must | — |
VOLAEUFIGERWERT | — | — | Must | — |
FEHLT | — | — | Must | — |
ANGABE_FUER_LIEFERSCHEIN | — | — | Must | — |
GRUNDLAGE_POG_ERMITTLUNG | — | — | Must | — |
| obiskennzahl * 00060 | obiskennzahl | string | X | — |
| position * 00070 | position | integer | Must | — |
| startdatum 00080 | startdatum | string (date-time) | X | — |
| wert * 00090 | wert | number (float) | Must | — |
| statuszusatzinformationen [ ] | — | object[] | May | — |
| art 00100 | Status type | Enum StatusArt | X | — |
PLAUSIBILISIERUNGSHINWEIS | — | — | X | — |
ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
KORREKTURGRUND | — | — | X | — |
GRUND_ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
GASQUALITAET | — | — | X | — |
MESSKLASSIFIZIERUNG | — | — | X | — |
| status 00110 | Status | Enum Status | X | — |
KUNDENSELBSTABLESUNG | — | — | X | — |
LEERSTAND | — | — | X | — |
REALER_ZAEHLERUEBERLAUF_GEPRUEFT | — | — | X | — |
PLAUSIBEL_WG_KONTROLLABLESUNG | — | — | X | — |
PLAUSIBEL_WG_KUNDENHINWEIS | — | — | X | — |
AUSTAUSCH_DES_ERSATZWERTES | — | — | X | — |
RECHENWERT | — | — | X | — |
BASIS_MME | — | — | X | — |
VERGLEICHSMESSUNG_GEEICHT | — | — | X | — |
VERGLEICHSMESSUNG_NICHT_GEEICHT | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_GEEICHTEN_WERTEN | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_NICHT_GEEICHTEN_WERTEN | — | — | X | — |
INTERPOLATION | — | — | X | — |
HALTEWERT | — | — | X | — |
BILANZIERUNG_NETZABSCHNITT | — | — | X | — |
HISTORISCHE_MESSWERTE | — | — | X | — |
STATISTISCHE_METHODE | — | — | X | — |
AUFTEILUNG | — | — | X | — |
VERWENDUNG_VON_WERTEN_DES_STOERMENGENZAEHLWERKS | — | — | X | — |
UMGANGS_UND_KORREKTURMENGEN | — | — | X | — |
ANGABEN_MESSLOKATION | — | — | X | — |
KEIN_ZUGANG | — | — | X | — |
KOMMUNIKATIONSSTOERUNG | — | — | X | — |
NETZAUSFALL | — | — | X | — |
SPANNUNGSAUSFALL | — | — | X | — |
STATUS_GERAETEWECHSEL | — | — | X | — |
KALIBRIERUNG | — | — | X | — |
GERAET_ARBEITET_AUSSERHALB_DER_BETRIEBSBEDINGUNGEN | — | — | X | — |
MESSEINRICHTUNG_GESTOERT_DEFEKT | — | — | X | — |
UNSICHERHEIT_MESSUNG | — | — | X | — |
BERUECKSICHTIGUNG_STOERMENGENZAEHLWERK | — | — | X | — |
MENGENUMWERTUNG_VOLLSTAENDIG | — | — | X | — |
UHRZEIT_GESTELLT_SYNCHRONISATION | — | — | X | — |
MESSWERT_UNPLAUSIBEL | — | — | X | — |
FALSCHER_WANDLERFAKTOR | — | — | X | — |
FEHLERHAFTE_ABLESUNG | — | — | X | — |
AENDERUNG_DER_BERECHNUNG | — | — | X | — |
UMBAU_DER_MESSLOKATION | — | — | X | — |
DATENBEARBEITUNGSFEHLER | — | — | X | — |
BRENNWERTKORREKTUR | — | — | X | — |
Z_ZAHL_KORREKTUR | — | — | X | — |
STOERUNG_DEFEKT_MESSEINRICHTUNG | — | — | X | — |
AENDERUNG_TARIFSCHALTZEITEN | — | — | X | — |
TARIFSCHALTGERAET_DEFEKT | — | — | X | — |
IMPULSWERTIGKEIT_NICHT_AUSREICHEND | — | — | X | — |
ENERGIEMENGE_IN_UNGEMESSENEM_ZEITINTERVALL | — | — | X | — |
ENERGIEMENGE_AUS_DEM_UNGEPAIRTEN_ZEITINTERVALL | — | — | X | — |
WARTUNGSARBEITEN_AN_GEEICHTEM_MESSGERAET | — | — | X | — |
GESTOERTE_WERTE | — | — | X | — |
WARTUNGSARBEITEN_AN_EICHRECHTSKONFORMEN_MESSGERAETEN | — | — | X | — |
KONSISTENZ_UND_SYNCHRONPRUEFUNG | — | — | X | — |
GRUND_ANGABEN_MESSLOKATION | — | — | X | — |
ANFORDERUNG_IN_DIE_VERGANGENHEIT_ZUM_ANGEFORDERTEN_ZEITPUNKT_LIEGT_KEIN_WERT_VOR | — | — | X | — |
UMSTELLUNG_GASQUALITAET | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
GESCHEITERT | — | — | X | — |
AUSGEBAUT | — | — | X | — |
| transaktionsdaten * | — | object | Must | — |
| anfrageReferenz 00120 | Application number / RFF+AGI | string | X | — |
| dokumentennummer * 00130 | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| kategorie * 00140 | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| nachrichtendatum * 00150 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenfunktion * 00160 | Message function code / BGM | string | Must | — |
| nachrichtenreferenznummer * 00170 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00180 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00190 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00200 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00210 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00220 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 13009 | Condition |
|---|---|---|---|---|
| UNB | — | — | Must | — |
0001 UNOC00010 | UN/ECE character set C | — | X | — |
0002 300020 | Version 3 | — | X | — |
000400030 | MP-ID Sender | — | X | — |
0007 1400040 | GS1 | — | X | — |
0007 50200050 | DE, DVGW Service & Consult GmbH | — | X | — |
001000060 | MP-ID recipient | — | X | — |
0007 1400070 | GS1 | — | X | — |
0007 50200080 | DE, DVGW Service & Consult GmbH | — | X | — |
001700090 | Date of creation | — | X | — |
001900100 | Time of creation | — | X | — |
002000110 | Interchange control reference | — | X | [918] |
0026 EM00120 | Energy quantity | — | X | — |
0035 100130 | Transmission file is a test | — | — | S [155] |
| UNH | — | — | Must | — |
006200140 | Message reference number | — | X | — |
0065 MSCONS00150 | Report on the consumption of measurable services | — | X | — |
0052 D00160 | Draft version | — | X | — |
0054 04B00170 | Edition 2004 - B | — | X | — |
0051 UN00180 | UN/CEFACT | — | X | — |
0057 2.500190 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 700200 | Process data report | — | X | — |
1001 Z2700210 | Transaction data in the calendar year before the start of supply | — | X | — |
100400220 | Document number | — | X | — |
1225 900230 | Original | — | X | — |
| DTM | — | — | Must | — |
2005 13700240 | Document-/message date/time | — | X | — |
238000250 | Date or time or time span, value | — | X | [931] [494] |
2379 30300260 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 AGI00270 | Application number | — | X | — |
115400280 | Reference number | — | X | [529] ⊻ ([531] ∧ [509]) |
| SG1.RFF | — | — | Must | — |
1153 Z1300290 | Check identifier | — | X | — |
1154 1300900300 | Meter reading value energy quantity (gas) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00310 | Document-/message sender or sender | — | X | — |
303900320 | MP-ID | — | X | [118] |
3055 900330 | GS1 | — | X | — |
3055 33200340 | DE, DVGW Service & Consult GmbH | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00350 | Message recipient | — | X | — |
303900360 | MP-ID | — | X | [118] |
3055 900370 | GS1 | — | X | — |
3055 33200380 | DE, DVGW Service & Consult GmbH | — | X | — |
| UNS | — | — | Must | — |
0081 D00390 | Separation of header and detail section | — | X | — |
| SG5.NAD | — | — | Must | — |
3035 DP00400 | Supply address | — | X | — |
| SG6.LOC | — | — | Must | — |
3227 17200410 | Reporting point | — | X | — |
322500420 | Designation | — | X | ([951] [510] ∧ ([522] ∨ [524])) ⊻ ([950] [514] ∧ ([151] ⊻ [152] ∧ (([523] ∨ [525])))) |
| SG9.LIN | — | — | Must | — |
108200430 | Line item number | — | X | [908] |
| SG9.PIA | — | — | Must | — |
4347 500440 | Product identification | — | X | — |
714000450 | Medium / OBIS code number | — | X | ([152] ∧ [51] ∧ [501]) ⊻ ([151] ∧ [501]) |
7143 SRW00460 | OBIS code | — | X | — |
| SG10.QTY | — | — | Must | — |
6063 22000470 | True value | — | X | — |
6063 6700480 | Substitute value | — | X | ([152] ∧ [32] ∧ ([33] ∨ [36] ∨ [42])) ⊻ [151] |
6063 20100490 | Proposed value | — | X | ([152] ∧ [35] ∧ ([33] ∨ [36]) ∧ [12]) |
6063 2000500 | Unusable value | — | X | ([152] ∧ [35] ∧ ([33] ∨ [36])) |
6063 18700510 | Forecast value | — | X | [152] ∧ [32] ∧ [33] ∧ [11] |
606000520 | Quantity | — | X | (([902] ∧ [937] [46] ∧ [573]) ∨ ([902] ∧ [907] [48] ∧ [62]) ∨ ([910] ∧ [906] [62]) [152]) ⊻ ([902] ∧ [906] ∧ [151]) |
| SG10.DTM | — | — | Must | [152] ⊻ ([151] ∧ [153]) |
2005 16300530 | Processing, start date/time | — | X | — |
238000540 | Date or time or time span, value | — | X | ((([UB2] ∧ [119]) ⊻ ([931] [38])) ∧ [495]) |
2379 30300550 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | [152] ⊻ ([151] ∧ [153]) |
2005 16400560 | Processing, end date/time | — | X | — |
238000570 | Date or time or time span, value | — | X | ((([UB2] ∧ [119]) ⊻ ([931] [38])) ∧ [495]) |
2379 30300580 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | [151] ∧ [154] |
2005 30600590 | Demand period | — | X | — |
238000600 | Date or time or time span, value | — | X | — |
2379 61000610 | CCYYMM | — | X | — |
| SG10.STS | — | — | Should | ([92] ⊻ [93] ⊻ [94]) ∧ [126] ∧ [152] |
9015 Z3300620 | Plausibility check note | — | X | — |
9013 Z8300630 | Customer self-reading | — | X | [5P0..1] |
9013 Z8400640 | Vacancy | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 Z8500650 | Actual meter overflow checked | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 Z8600660 | Plausible due to check reading | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 Z8700670 | Plausible due to customer information | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
9013 ZC300680 | Exchange of the substitute value | — | X | [5P0..1] |
9013 ZR500690 | Calculated value | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] |
| SG10.STS | — | — | Must | [152] ∧ ([92] ⊻ [94]) |
9015 Z3200700 | Substitute value formation procedure | — | X | — |
9013 Z8900710 | Comparative measurement (not calibrated) | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9000720 | Meter reading value simulation from calibrated values | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9100730 | Meter reading value simulation from non-calibrated values | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9200740 | Interpolation | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9300750 | Hold value | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9400760 | Balancing grid section | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9500770 | Historical meter reading values | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZQ800780 | Distribution | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZQ900790 | Use of values from the fault quantity register | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZR000800 | Bypass and correction quantities | — | X | [4P0..1] ⊻ [6P0..1] |
9013 ZS000810 | Substitute value procedure according to the details at the level of the metering location | — | X | [46] ∧ [568] |
| SG10.STS | — | — | Should | [127] ∧ [559] ∧ [152] |
9015 Z3400820 | Reason for correction | — | X | — |
9013 Z7400830 | no access | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z7500840 | Communication fault | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z7600850 | Grid outage | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z7800860 | Device replacement | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z8000870 | Device operates outside the operating conditions | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z8100880 | Measuring equipment faulty/defective | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z8200890 | Measurement uncertainty | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 Z9800900 | Consideration of the fault quantity register | — | X | [4P0..1] ⊻ [6P0..1] |
9013 Z9900910 | Volume conversion incomplete | — | X | [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA000920 | Time set /synchronisation | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA100930 | Meter reading value implausible | — | X | [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA400940 | Incorrect reading | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA500950 | Change of the calculation | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA600960 | Conversion of the metering location | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA700970 | Data processing error | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA800980 | Calorific value correction | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZA900990 | Z-number correction | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZB001000 | Fault / defect of measuring equipment | — | X | [4P0..1] ⊻ [5P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZC401010 | Pulse value not sufficient | — | X | [4P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZJ901020 | Energy quantity from the unpaired time interval | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZR101030 | Maintenance work on a calibrated measuring device | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR201040 | faulty values | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR301050 | Maintenance work on measuring devices compliant with calibration law | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
9013 ZR401060 | Consistency and synchronisation check | — | X | [4P0..1] ⊻ [6P0..1] ⊻ [7P0..1] ⊻ [8P0..1] |
| SG10.STS | — | — | Must | [92] ∧ [152] |
9015 Z4001070 | Reason for substitute value formation | — | X | — |
9013 Z7401080 | no access | — | X | [4P0..1] |
9013 Z7501090 | Communication fault | — | X | [4P0..1] |
9013 Z7601100 | Grid outage | — | X | [4P0..1] |
9013 Z7801110 | Device replacement | — | X | [4P0..1] |
9013 Z8001120 | Device operates outside the operating conditions | — | X | [4P0..1] |
9013 Z8101130 | Measuring equipment faulty/defective | — | X | [4P0..1] |
9013 Z8201140 | Measurement uncertainty | — | X | [4P0..1] |
9013 Z9801150 | Consideration of the fault quantity register | — | X | [4P0..1] |
9013 Z9901160 | Volume conversion incomplete | — | X | [4P0..1] |
9013 ZA001170 | Time set /synchronisation | — | X | [4P0..1] |
9013 ZA101180 | Meter reading value implausible | — | X | [4P0..1] |
9013 ZA401190 | Incorrect reading | — | X | [4P0..1] |
9013 ZA501200 | Change of the calculation | — | X | [4P0..1] |
9013 ZA601210 | Conversion of the metering location | — | X | [4P0..1] |
9013 ZA701220 | Data processing error | — | X | [4P0..1] |
9013 ZB001230 | Fault / defect of measuring equipment | — | X | [4P0..1] |
9013 ZC401240 | Pulse value not sufficient | — | X | [4P0..1] |
9013 ZR101250 | Maintenance work on a calibrated measuring device | — | X | [4P0..1] |
9013 ZR201260 | faulty values | — | X | [4P0..1] |
9013 ZR301270 | Maintenance work on measuring devices compliant with calibration law | — | X | [4P0..1] |
9013 ZR401280 | Consistency and synchronisation check | — | X | [4P0..1] |
9013 ZS901290 | Reason for substitute value formation according to the information at metering location level | — | X | [46] ∧ [570] |
| SG10.STS | — | — | Should | [97] ∧ [152] |
9015 Z3101300 | Gas quality | — | X | — |
9013 ZG301310 | Change of gas quality | — | X | — |
| UNT | — | — | Must | — |
007401320 | Number of segments in a message | — | X | — |
006201330 | Message reference number | — | X | — |
| UNZ | — | — | Must | — |
003601340 | Interchange counter | — | X | — |
002001350 | Interchange control reference | — | X | — |
Conditions of this table
The free text of the 57 conditions referenced by the rows above. All conditions of the message type are listed in the condition index MSCONS.
| Marker | Condition |
|---|---|
| [11] | If SG9 PIA+5+7-0?:52.0.22/7-0?:54.0.16/7-0?:54.0.20/7-0?:54.0.22 |
| [12] | If not SG9 PIA+5+7-0?:52.0.22/7-0?:54.0.16/7-0?:54.0.20/7-0?:54.0.22 |
| [32] | if MP-ID in SG2 NAD+MS in the role NB |
| [33] | if MP-ID in SG2 NAD+MR in the role LF |
| [35] | if MP-ID in SG2 NAD+MS in the role MSB |
| [36] | if MP-ID in SG2 NAD+MR in the role NB |
| [38] | if the ID of the metering location is stated in SG6 LOC+172 DE3225 |
| [42] | If MP-ID in SG2 NAD+MR in the role MSB |
| [46] | If the value in SG6 LOC+172 DE3225 has exactly 11 digits |
| [48] | If SG9 PIA+5+7-0?:52.0.22 |
| [51] | If SG9 PIA+5+7-0?:33.86.0 is present, SG9 PIA+5+7-0?:52.0.22/7-0?:54.0.16/7-0?:54.0.20/7-0?:54.0.22 must no longer be specified by repeating SG9 LIN in the same message |
| [62] | If the value in SG6 LOC+172 DE3225 has exactly 33 digits |
| [92] | If SG10 QTY DE6063 with value 67 is present |
| [93] | If SG10 QTY DE6063 with value 220 is present |
| [94] | If SG10 QTY DE6063 with value 201 is present |
| [97] | If this concerns the transmission of a value due to the change of the gas quality |
| [118] | Only MP-ID from the gas division |
| [119] | if the ID of the market location is stated in SG6 LOC+172 DE3225 |
| [126] | if plausibility check notices exist |
| [127] | if a correction reason has to be stated |
| [151] | If BGM+Z27 (transaction data in the calendar year before start of supply) present. |
| [152] | If BGM+7 (process data report) present. |
| [153] | If SG9 PIA+5+7-0?:33.86.0 is present |
| [154] | If SG9 PIA+5+7-0?:33.47.0 is present |
| [155] | If the transmission file is exchanged for test purposes. |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [501] | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| [509] | Note: If this is a correction energy quantity, the reference to the MSCONS in which the meter reading was transmitted in advance must be specified here. |
| [510] | Note: Use of the ID of the metering location |
| [514] | Note: Use of the ID of the market location |
| [522] | Note: Only for the transmission of the correction energy quantities in the time interval between two metered values. |
| [523] | Note: Only for the transmission of the energy quantity in the time interval between two metered values before the grid usage settlement. |
| [524] | Note: Only if it concerns the transmission of the billing calorific value and Z number for the period requested by the supplier via a business data request. |
| [525] | Note: Only for the transmission of the energy quantity in the time interval for a market location without a metering location (flat-rate installation) if one of the events from chapter 4.2 has occurred. |
| [529] | Note: Value from BGM+7 DE1004 of the ORDERS with which the request for meter reading values was made. |
| [531] | Note: Value from BGM+7 DE1004 of the MSCONS with which the meter reading was transmitted. |
| [559] | Note: A correction reason is to be specified if: 1. a preliminary value already transmitted to the MP is replaced by a substitute value after cancellation, or 2. a substitute value already transmitted to the MP is replaced by a substitute value after cancellation, or 3. a true value already transmitted to the MP is replaced by a substitute value after cancellation, or 4. a true value already transmitted to the MP is replaced by a true value after cancellation. |
| [568] | Note: Use is permitted only if it is a 1:n relationship between market and metering location and different substitute value determination procedures have been used and communicated at the level of the metering location. |
| [570] | Note: Use is permitted only if it is a 1:n relationship between market and metering location and different reasons for the substitute value determination exist at the level of the metering location and have been communicated. |
| [573] | Note: An energy quantity in the gas division is to be rounded to whole kilowatt hours in accordance with DVGW G685 worksheet 4 chapter 5.3. |
| [902] | Format: Possible value: ≥ 0 |
| [906] | Format: max. 3 decimal places |
| [907] | Format: max. 4 decimal places |
| [908] | Format: possible values: 1 to n |
| [910] | Format: Possible value: < 0 or ≥ 0 |
| [918] | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [UB2] | ([931] ∧ [934] [490]) ⊻ ([931] ∧ [935] [491]) |
| [5P0..1] | [93] If SG10 QTY DE6063 with value 220 present |
| [4P0..1] | [92] If SG10 QTY DE6063 with value 67 present |
| [6P0..1] | [94] If SG10 QTY DE6063 with value 201 present |
| [7P0..1] | [95] If SG10 QTY DE6063 with value 20 present |
| [8P0..1] | [96] If SG10 QTY DE6063 with value Z18 present |
Example message
Example 1
UNA:+.? '
UNB+UNOC:3+9870013800007:502+9800044300007:502+{{date}}:{{time}}+165425++EM'
UNH+434072+MSCONS:D:04B:UN:2.5'
BGM+7+34072BGM+9'
DTM+137:202610011100?+00:303'
RFF+AGI:12345678910'
RFF+Z13:13009'
NAD+MS+9870013800007::332'
NAD+MR+9800044300007::332'
UNS+D'
NAD+DP'
LOC+172+50074561188'
LIN+1'
PIA+5+7-0?:33.86.0:SRW'
QTY+220:1000'
DTM+163:202506010400?+00:303'
DTM+164:202507010400?+00:303'
UNT+16+434072'
UNZ+1+165425'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"ENERGIEMENGE": [1 item
{5 fields
"energieverbrauch": [1 item
{6 fields
"transaktionsdaten": {12 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 2
UNA:+.? '
UNB+UNOC:3+9870013800007:502+9800044300007:502+{{date}}:{{time}}+P1001099071538++EM'
UNH+P1001099071539+MSCONS:D:04B:UN:2.5'
BGM+7+P1001099071539+9'
DTM+137:202610011100?+00:303'
RFF+AGI:PP172409301012154888888888888563000'
RFF+Z13:13009'
NAD+MS+9870013800007::332'
NAD+MR+9800044300007::332'
UNS+D'
NAD+DP'
LOC+172+DE7000871626900000000000070100000'
LIN+1'
PIA+5+7-0?:54.0.22:SRW'
QTY+220:11.549'
DTM+163:202309270400?+00:303'
DTM+164:202409270400?+00:303'
STS+Z33++Z86'
STS+Z31++ZG3'
LIN+2'
PIA+5+7-0?:54.0.22:SRW'
QTY+220:0.9693'
DTM+163:202309270400?+00:303'
DTM+164:202409270400?+00:303'
STS+Z33++Z86'
STS+Z31++ZG3'
UNT+25+P1001099071539'
UNZ+1+P1001099071538'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"ENERGIEMENGE": [1 item
{5 fields
"energieverbrauch": [2 items
{7 fields
"statuszusatzinformationen": [2 items
{2 fields
{2 fields
{7 fields
"statuszusatzinformationen": [2 items
{2 fields
{2 fields
"transaktionsdaten": {12 fields
"absender": {6 fields
"empfaenger": {6 fields
Download: EDIFACT file · BO4E JSON
Example 3
UNA:+.? '
UNB+UNOC:3+9870006600000:502+9800009600004:502+{{date}}:{{time}}+MR67ZDIB++EM'
UNH+MQYJJOFQ+MSCONS:D:04B:UN:2.5'
BGM+Z27+MRKIPLPF+9'
DTM+137:202606240949?+00:303'
RFF+Z13:13009'
NAD+MS+9870006600000::332'
NAD+MR+9800009600004::332'
UNS+D'
NAD+DP'
LOC+172+50074561188'
LIN+1'
PIA+5+7-0?:33.47.0:SRW'
QTY+220:500'
DTM+306:202603:610'
STS+Z33++Z83'
UNT+15+MQYJJOFQ'
UNZ+1+MR67ZDIB'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"ENERGIEMENGE": [1 item
{5 fields
"energieverbrauch": [1 item
{6 fields
"statuszusatzinformationen": [1 item
{2 fields
"transaktionsdaten": {11 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Energy quantity (gas) |
| AHB | MSCONS AHB |
| Response to check identifier | 17102 |
| Transmission channel | AS4 |
This check identifier is used in 19 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GeLi Gas 2.0 | Request and provision of meter reading values | MSB → NB | Meter reading transmission |
| GeLi Gas 2.0 | Request and provision of meter reading values | NB → MSB | Transmission of substitute values |
| GeLi Gas 2.0 | Request and provision of meter reading values | NB → LF | Meter reading transmission |
| GeLi Gas 2.0 | Transmission of the energy and demand values measured so far | NB → LF | Energy and demand values measured so far |
| GeLi Gas 2.0 | Periodic/regular meter reading transmission | MSB → NB | Meter reading date for measuring equipment with balancing based on profiles |
| GeLi Gas 2.0 | Periodic/regular meter reading transmission | MSB → NB | Regular reading of measuring equipment with RLM |
| GeLi Gas 2.0 | Periodic/regular meter reading transmission | MSB → NB | End of supply / deregistration request |
| GeLi Gas 2.0 | Off-cycle meter reading transmission | MSB → NB | Interim meter reading |
| GeLi Gas 2.0 | Request for calorific value and conversion factor | NB → LF | Transmission of billing calorific value and conversion factor |
| GeLi Gas 2.0 | Business data request from LF to NB | NB → LF | Response |
| GeLi Gas 2.0 | Billing of grid usage | NB → LF | ongoing meter reading values |
| AWH WiM gas 2.0 | Transmission of values from MSB to NB | MSB → NB | Values |
| WiM gas | Ch. B 5.1.3 No. 7 | MSBN → NB | Transmission of final reading values by MSBN or MSBA |
| WiM gas | Ch. B 5.1.3 No. 7 | MSBA → NB | Transmission of final reading values by MSBN or MSBA |
| GeLi Gas | Ch. D 1.2.4 No. 11 | NB → LF | Meter reading transmission |
| GeLi Gas | Ch. D 1.2.4 No. 7 | MSB → NB | Meter reading transmission |
| GeLi Gas | Ch. D 1.2.4 No. 9 | NB → MSB | Transmission of substitute values |
| GeLi Gas | Ch. D 2.2 No. 2 | NB → LF | Response |
| GeLi Gas | Ch. D 3.2 No. 2 | NB → LF | Response |
Individual entries from format version 202604
The check identifiers table of format version 202610 does not carry this entry: process step. It comes from version 202604. Version 202604 also carries this check identifier in contexts that the table of version 202610 does not know; they are included in the list above. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202610.
Transaction and responses
Role of this check identifier: response. Basis: the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 17102 | Request for values | ORDERS | explicit |
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfrageReferenz | SG1.RFF+AGI | dokumentennummer |
RFF+AGI quotes the BGM of the request; the target is its dokumentennummer. Measured: 17102 carries dokumentennummer in BGM+[7|Z28|Z48].
Check identifiers of the same AHB table: No other check identifier of message type MSCONS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 159 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains 3 transactions for this check identifier under the message type mscons. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.