Check identifier 13016 — Energy quantity & max. demand (Electricity)
Check identifier 13016 · EDIFACT message type MSCONS · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 13016 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| ENERGIEMENGE [ ] * | — | object[] | Must | — |
| konfiguration 00010 | konfiguration | string | X | — |
| lokationsId * 00020 | Unique number of the market location or of the metering location to which the energy quantity belongs | string | X | — |
| energieverbrauch [ ] * | — | object[] | Must | — |
| enddatum 00030 | enddatum | string (date-time) | X | — |
| leistungsperiode 00040 | leistungsperiode | string | X | — |
| messwertstatus * 00050 | The status of a meter reading | Enum Messwertstatus | Must | — |
ABGELESEN | — | — | Must | — |
ERSATZWERT | — | — | Must | — |
VORSCHLAGSWERT | — | — | Must | — |
NICHT_VERWENDBAR | — | — | Must | — |
PROGNOSEWERT | — | — | Must | — |
ENERGIEMENGESUMMIERT | — | — | Must | — |
VOLAEUFIGERWERT | — | — | Must | — |
FEHLT | — | — | Must | — |
ANGABE_FUER_LIEFERSCHEIN | — | — | Must | — |
GRUNDLAGE_POG_ERMITTLUNG | — | — | Must | — |
| obiskennzahl * 00060 | obiskennzahl | string | X | — |
| position * 00070 | position | integer | Must | — |
| startdatum 00080 | startdatum | string (date-time) | X | — |
| wert * 00090 | wert | number (float) | Must | — |
| statuszusatzinformationen [ ] | — | object[] | May | — |
| art 00100 | Status type | Enum StatusArt | X | — |
PLAUSIBILISIERUNGSHINWEIS | — | — | X | — |
ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
KORREKTURGRUND | — | — | X | — |
GRUND_ERSATZWERTBILDUNGSVERFAHREN | — | — | X | — |
GASQUALITAET | — | — | X | — |
MESSKLASSIFIZIERUNG | — | — | X | — |
| status 00110 | Status | Enum Status | X | — |
KUNDENSELBSTABLESUNG | — | — | X | — |
LEERSTAND | — | — | X | — |
REALER_ZAEHLERUEBERLAUF_GEPRUEFT | — | — | X | — |
PLAUSIBEL_WG_KONTROLLABLESUNG | — | — | X | — |
PLAUSIBEL_WG_KUNDENHINWEIS | — | — | X | — |
AUSTAUSCH_DES_ERSATZWERTES | — | — | X | — |
RECHENWERT | — | — | X | — |
BASIS_MME | — | — | X | — |
VERGLEICHSMESSUNG_GEEICHT | — | — | X | — |
VERGLEICHSMESSUNG_NICHT_GEEICHT | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_GEEICHTEN_WERTEN | — | — | X | — |
MESSWERTNACHBILDUNG_AUS_NICHT_GEEICHTEN_WERTEN | — | — | X | — |
INTERPOLATION | — | — | X | — |
HALTEWERT | — | — | X | — |
BILANZIERUNG_NETZABSCHNITT | — | — | X | — |
HISTORISCHE_MESSWERTE | — | — | X | — |
STATISTISCHE_METHODE | — | — | X | — |
AUFTEILUNG | — | — | X | — |
VERWENDUNG_VON_WERTEN_DES_STOERMENGENZAEHLWERKS | — | — | X | — |
UMGANGS_UND_KORREKTURMENGEN | — | — | X | — |
ANGABEN_MESSLOKATION | — | — | X | — |
KEIN_ZUGANG | — | — | X | — |
KOMMUNIKATIONSSTOERUNG | — | — | X | — |
NETZAUSFALL | — | — | X | — |
SPANNUNGSAUSFALL | — | — | X | — |
STATUS_GERAETEWECHSEL | — | — | X | — |
KALIBRIERUNG | — | — | X | — |
GERAET_ARBEITET_AUSSERHALB_DER_BETRIEBSBEDINGUNGEN | — | — | X | — |
MESSEINRICHTUNG_GESTOERT_DEFEKT | — | — | X | — |
UNSICHERHEIT_MESSUNG | — | — | X | — |
BERUECKSICHTIGUNG_STOERMENGENZAEHLWERK | — | — | X | — |
MENGENUMWERTUNG_VOLLSTAENDIG | — | — | X | — |
UHRZEIT_GESTELLT_SYNCHRONISATION | — | — | X | — |
MESSWERT_UNPLAUSIBEL | — | — | X | — |
FALSCHER_WANDLERFAKTOR | — | — | X | — |
FEHLERHAFTE_ABLESUNG | — | — | X | — |
AENDERUNG_DER_BERECHNUNG | — | — | X | — |
UMBAU_DER_MESSLOKATION | — | — | X | — |
DATENBEARBEITUNGSFEHLER | — | — | X | — |
BRENNWERTKORREKTUR | — | — | X | — |
Z_ZAHL_KORREKTUR | — | — | X | — |
STOERUNG_DEFEKT_MESSEINRICHTUNG | — | — | X | — |
AENDERUNG_TARIFSCHALTZEITEN | — | — | X | — |
TARIFSCHALTGERAET_DEFEKT | — | — | X | — |
IMPULSWERTIGKEIT_NICHT_AUSREICHEND | — | — | X | — |
ENERGIEMENGE_IN_UNGEMESSENEM_ZEITINTERVALL | — | — | X | — |
ENERGIEMENGE_AUS_DEM_UNGEPAIRTEN_ZEITINTERVALL | — | — | X | — |
WARTUNGSARBEITEN_AN_GEEICHTEM_MESSGERAET | — | — | X | — |
GESTOERTE_WERTE | — | — | X | — |
WARTUNGSARBEITEN_AN_EICHRECHTSKONFORMEN_MESSGERAETEN | — | — | X | — |
KONSISTENZ_UND_SYNCHRONPRUEFUNG | — | — | X | — |
GRUND_ANGABEN_MESSLOKATION | — | — | X | — |
ANFORDERUNG_IN_DIE_VERGANGENHEIT_ZUM_ANGEFORDERTEN_ZEITPUNKT_LIEGT_KEIN_WERT_VOR | — | — | X | — |
UMSTELLUNG_GASQUALITAET | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_VORHANDEN_UND_KOMMUNIZIERT | — | — | X | — |
ZAEHLERSTAND_ZUM_BEGINN_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
ZAEHLERSTAND_ZUM_ENDE_DER_ANGEGEBENEN_ENERGIEMENGE_NICHT_VORHANDEN_DA_MENGENABGRENZUNG | — | — | X | — |
GESCHEITERT | — | — | X | — |
AUSGEBAUT | — | — | X | — |
| transaktionsdaten * | — | object | Must | — |
| anfrageReferenz 00120 | Application number / RFF+AGI | string | X | — |
| dokumentennummer * 00130 | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| kategorie * 00140 | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| nachrichtendatum * 00150 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenfunktion * 00160 | Message function code / BGM | string | Must | — |
| nachrichtenreferenznummer * 00170 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00180 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00190 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00200 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00210 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00220 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 13016 | Condition |
|---|---|---|---|---|
| UNB | — | — | Must | — |
0001 UNOC00010 | UN/ECE character set C | — | X | — |
0002 300020 | Version 3 | — | X | — |
000400030 | MP-ID Sender | — | X | — |
0007 1400040 | GS1 | — | X | — |
0007 50000050 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
001000060 | MP-ID recipient | — | X | — |
0007 1400070 | GS1 | — | X | — |
0007 50000080 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
001700090 | Date of creation | — | X | — |
001900100 | Time of creation | — | X | — |
002000110 | Interchange control reference | — | X | [918] |
0026 EM00120 | Energy quantity | — | X | — |
0035 100130 | Transmission file is a test | — | — | S [155] |
| UNH | — | — | Must | — |
006200140 | Message reference number | — | X | — |
0065 MSCONS00150 | Report on the consumption of measurable services | — | X | — |
0052 D00160 | Draft version | — | X | — |
0054 04B00170 | Edition 2004 - B | — | X | — |
0051 UN00180 | UN/CEFACT | — | X | — |
0057 2.500190 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z2800200 | Energy quantity and maximum demand | — | X | — |
1001 Z4200210 | Delivery note energy price / demand price | — | X | [492] ∧ [32] ∧ [33] |
100400220 | Document number | — | X | — |
1225 900230 | Original | — | X | — |
| DTM | — | — | Must | — |
2005 13700240 | Document-/message date/time | — | X | — |
238000250 | Date or time or time span, value | — | X | [931] [494] |
2379 30300260 | CCYYMMDDHHMMZZZ | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 AGI00270 | Application number | — | X | — |
115400280 | Reference number | — | X | [528] ∨ [553] |
| SG1.RFF | — | — | Must | — |
1153 Z1300290 | Check identifier | — | X | — |
1154 1301600300 | Energy quantity and maximum demand | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00310 | Document-/message sender or sender | — | X | — |
303900320 | MP-ID | — | X | [117] |
3055 900330 | GS1 | — | X | — |
3055 29300340 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00350 | Message recipient | — | X | — |
303900360 | MP-ID | — | X | [117] |
3055 900370 | GS1 | — | X | — |
3055 29300380 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| UNS | — | — | Must | — |
0081 D00390 | Separation of header and detail section | — | X | — |
| SG5.NAD | — | — | Must | — |
3035 DP00400 | Supply address | — | X | — |
| SG6.LOC | — | — | Must | — |
3227 17200410 | Reporting point | — | X | — |
322500420 | Designation | — | X | [950] [514] |
| SG9.LIN | — | — | Must | — |
108200430 | Line item number | — | X | [908] |
| SG9.PIA | — | — | Must | — |
4347 500440 | Product identification | — | X | — |
714000450 | Medium / OBIS code number | — | X | ([69] ∧ [501] ∧ [566]) ⊻ ([91] ∧ [501]) |
7143 SRW00460 | OBIS code | — | X | [79] |
7143 Z0200470 | BDEW OBIS-like code | — | X | [78] |
| SG10.QTY | — | — | Must | — |
6063 22000480 | True value | — | X | [69] |
6063 6700490 | Substitute value | — | X | [69] |
6063 Z1800500 | Preliminary value | — | X | [35] ∧ [69] |
6063 Z3100510 | Entry for the delivery note | — | X | [91] |
606000520 | Quantity | — | X | [902] ∧ [906] |
| SG10.DTM | — | — | Must | [73] |
2005 16300530 | Processing, start date/time | — | X | — |
238000540 | Date or time or time span, value | — | X | [UB1] ∧ [495] |
2379 30300550 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | [73] |
2005 16400560 | Processing, end date/time | — | X | — |
238000570 | Date or time or time span, value | — | X | [UB1] ∧ [495] |
2379 30300580 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.DTM | — | — | Must | [72] |
2005 30600590 | Demand period | — | X | — |
238000600 | Date or time or time span, value | — | X | — |
2379 10200610 | CCYYMMDD | — | X | ([91] ∧ [580]) |
2379 61000620 | CCYYMM | — | X | ([69] ∧ [581]) ⊻ ([91] ∧ ([578] ⊻ [579])) |
| SG10.STS | — | — | Should | ([92] ⊻ [93]) ∧ [126] |
9015 Z3300630 | Plausibility check note | — | X | — |
9013 Z8300640 | Customer self-reading | — | X | [5P0..1] |
9013 Z8400650 | Vacancy | — | X | [4P0..1] ⊻ [5P0..1] |
9013 Z8500660 | Actual meter overflow checked | — | X | [4P0..1] ⊻ [5P0..1] |
9013 Z8600670 | Plausible due to check reading | — | X | [4P0..1] ⊻ [5P0..1] |
9013 Z8700680 | Plausible due to customer information | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZC300690 | Exchange of the substitute value | — | X | [4P0..1] ⊻ [5P0..1] |
| SG10.STS | — | — | Must | [92] |
9015 Z3200700 | Substitute value formation procedure | — | X | — |
9013 Z8800710 | Comparative measurement (calibrated) | — | X | [4P0..1] |
9013 Z8900720 | Comparative measurement (not calibrated) | — | X | [4P0..1] |
9013 Z9200730 | Interpolation | — | X | [4P0..1] |
9013 ZJ200740 | Statistical method | — | X | [4P0..1] |
9013 ZS000750 | Substitute value procedure according to the details at the level of the metering location | — | X | [46] ∧ [568] |
| SG10.STS | — | — | Should | [127] ∧ [541] |
9015 Z3400760 | Reason for correction | — | X | — |
9013 Z7400770 | no access | — | X | [4P0..1] |
9013 Z7500780 | Communication fault | — | X | [4P0..1] |
9013 Z7600790 | Grid outage | — | X | [4P0..1] |
9013 Z7700800 | Voltage failure | — | X | [4P0..1] |
9013 Z7800810 | Device replacement | — | X | [4P0..1] |
9013 Z7900820 | Calibration | — | X | [4P0..1] |
9013 Z8000830 | Device operates outside the operating conditions | — | X | [4P0..1] |
9013 Z8100840 | Measuring equipment faulty/defective | — | X | [4P0..1] |
9013 Z8200850 | Measurement uncertainty | — | X | [4P0..1] |
9013 ZA000860 | Time set /synchronisation | — | X | [4P0..1] |
9013 ZA100870 | Meter reading value implausible | — | X | [4P0..1] |
9013 ZA300880 | Incorrect transformer factor | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA400890 | Incorrect reading | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA500900 | Change of the calculation | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA600910 | Conversion of the metering location | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZA700920 | Data processing error | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZB000930 | Fault / defect of measuring equipment | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZB900940 | Change tariff switching times | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZC200950 | Tariff switching device defective | — | X | [4P0..1] ⊻ [5P0..1] |
9013 ZC400960 | Pulse value not sufficient | — | X | [4P0..1] |
| SG10.STS | — | — | Must | [92] |
9015 Z4000970 | Reason for substitute value formation | — | X | — |
9013 Z7400980 | no access | — | X | [4P0..1] |
9013 Z7500990 | Communication fault | — | X | [4P0..1] |
9013 Z7601000 | Grid outage | — | X | [4P0..1] |
9013 Z7701010 | Voltage failure | — | X | [4P0..1] |
9013 Z7801020 | Device replacement | — | X | [4P0..1] |
9013 Z7901030 | Calibration | — | X | [4P0..1] |
9013 Z8001040 | Device operates outside the operating conditions | — | X | [4P0..1] |
9013 Z8101050 | Measuring equipment faulty/defective | — | X | [4P0..1] |
9013 Z8201060 | Measurement uncertainty | — | X | [4P0..1] |
9013 ZA001070 | Time set /synchronisation | — | X | [4P0..1] |
9013 ZA101080 | Meter reading value implausible | — | X | [4P0..1] |
9013 ZA301090 | Incorrect transformer factor | — | X | [4P0..1] |
9013 ZA401100 | Incorrect reading | — | X | [4P0..1] |
9013 ZA501110 | Change of the calculation | — | X | [4P0..1] |
9013 ZA601120 | Conversion of the metering location | — | X | [4P0..1] |
9013 ZA701130 | Data processing error | — | X | [4P0..1] |
9013 ZB001140 | Fault / defect of measuring equipment | — | X | [4P0..1] |
9013 ZB901150 | Change tariff switching times | — | X | [4P0..1] |
9013 ZC201160 | Tariff switching device defective | — | X | [4P0..1] |
9013 ZC401170 | Pulse value not sufficient | — | X | [4P0..1] |
9013 ZS901180 | Reason for substitute value formation according to the information at metering location level | — | X | [46] ∧ [570] |
| UNT | — | — | Must | — |
007401190 | Number of segments in a message | — | X | — |
006201200 | Message reference number | — | X | — |
| UNZ | — | — | Must | — |
003601210 | Interchange counter | — | X | — |
002001220 | Interchange control reference | — | X | — |
Conditions of this table
The free text of the 40 conditions referenced by the rows above. All conditions of the message type are listed in the condition index MSCONS.
| Marker | Condition |
|---|---|
| [32] | if MP-ID in SG2 NAD+MS in the role NB |
| [33] | if MP-ID in SG2 NAD+MR in the role LF |
| [35] | if MP-ID in SG2 NAD+MS in the role MSB |
| [46] | If the value in SG6 LOC+172 DE3225 has exactly 11 digits |
| [69] | If BGM+Z28 present |
| [72] | If SG9 PIA+5+1-b?:1.6.0/1-b?:3.6.0/1-b?:4.6.0/1-66?:13.6.0/1-66?:14.6.0 (b=channel: value according to the code list of the OBIS codes and media) is present |
| [73] | If SG9 PIA+5+1-b?:1.9.e/1-b?:3.9.0/1-b?:4.9.0/1-66?:13.9.0/1-66?:14.9.0 (b=channel: value according to the code list of the OBIS codes and media, e=tariff: value according to the code list of the OBIS codes and media) is present |
| [78] | If SG9 PIA+5+1-66?:13.6.0/1-66?:14.6.0/1-66?:13.9.0/1-66?:14.9.0 is present |
| [79] | If SG9 PIA+5+1-66?:13.6.0/1-66?:14.6.0/1-66?:13.9.0/1-66?:14.9.0 is not present |
| [91] | If BGM+Z42 present |
| [92] | If SG10 QTY DE6063 with value 67 is present |
| [93] | If SG10 QTY DE6063 with value 220 is present |
| [117] | Only MP-ID from the electricity division |
| [126] | if plausibility check notices exist |
| [127] | if a correction reason has to be stated |
| [155] | If the transmission file is exchanged for test purposes. |
| [492] | if MP-ID in NAD+MR from division electricity |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that. |
| [495] | The point in time must be ≤ the value in DE2380 of DTM+137 |
| [501] | Note: Only the values that are marked with the corresponding check identifier in the EDI@Energy code list of the OBIS codes and media are permitted. |
| [514] | Note: Use of the ID of the market location |
| [528] | Note: Value from BGM+Z28 DE1004 of the ORDERS with which the request for meter reading values was made. |
| [541] | Note: A correction reason is to be specified if: 1. a preliminary value already transmitted to the MP is replaced by a substitute value after cancellation, or 2. a substitute value already transmitted to the MP is replaced by a substitute value after cancellation, or 3. a true value already transmitted to the MP is replaced by a substitute value after cancellation, or 4. a true value already transmitted to the MP is replaced by a true value after cancellation. |
| [553] | Note: Value from BGM+Z34 DE1004 of the ORDERS with which the complaint regarding values was made |
| [566] | Note: Only the values that were transmitted by the MSB in the previous master data exchange for this reporting point at the point in time are permitted. |
| [568] | Note: Use is permitted only if it is a 1:n relationship between market and metering location and different substitute value determination procedures have been used and communicated at the level of the metering location. |
| [570] | Note: Use is permitted only if it is a 1:n relationship between market and metering location and different reasons for the substitute value determination exist at the level of the metering location and have been communicated. |
| [578] | Note: If this concerns the transmission of the demand value for the grid fees with an annual demand price system. |
| [579] | Note: If this concerns the transmission of the demand value for the grid fees with a monthly demand price system. |
| [580] | Note: If this concerns the transmission of the demand value for the grid fees with a daily demand price system. |
| [581] | Note: If this concerns the transmission of the monthly maximum in accordance with WiM. |
| [902] | Format: Possible value: ≥ 0 |
| [906] | Format: max. 3 decimal places |
| [908] | Format: possible values: 1 to n |
| [918] | Format: Characters from the character set defined via UNOC, where only capital letters are permitted among the letters. |
| [931] | Format: ZZZ = +00 |
| [950] | Format: market location ID |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [5P0..1] | [93] If SG10 QTY DE6063 with value 220 present |
| [4P0..1] | [92] If SG10 QTY DE6063 with value 67 present |
Example message
Example 1
UNA:+.? '
UNB+UNOC:3+9900321000005:500+9903790000002:500+{{date}}:{{time}}+927877++EM'
UNH+780170+MSCONS:D:04B:UN:2.5'
BGM+Z42+780170BGM+9'
DTM+137:202610011100?+00:303'
RFF+Z13:13016'
NAD+MS+9900321000005::293'
NAD+MR+9903790000002::293'
UNS+D'
NAD+DP'
LOC+172+50074561188'
LIN+1'
PIA+5+1-1?:1.6.0:SRW'
QTY+Z31:5000'
DTM+306:20250901:610'
UNT+14+780170'
UNZ+1+927877'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"ENERGIEMENGE": [1 item
{5 fields
"energieverbrauch": [1 item
{5 fields
"transaktionsdaten": {11 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 2
UNA:+.? '
UNB+UNOC:3+9904813000002:500+9903790000002:500+{{date}}:{{time}}+927877++EM'
UNH+780170+MSCONS:D:04B:UN:2.5'
BGM+Z28+780170BGM+9'
DTM+137:202610011100?+00:303'
RFF+AGI:12345678910'
RFF+Z13:13016'
NAD+MS+9904813000002::293'
NAD+MR+9903790000002::293'
UNS+D'
NAD+DP'
LOC+172+50074561188'
LIN+1'
PIA+5+1-1?:1.6.0:SRW'
QTY+Z18:5000'
DTM+306:202501:610'
UNT+15+780170'
UNZ+1+927877'[1 item
{6 fields
"data": {3 fields
"stammdaten": {1 field
"ENERGIEMENGE": [1 item
{5 fields
"energieverbrauch": [1 item
{5 fields
"transaktionsdaten": {12 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ÜNB.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Energy quantity and max. demand (electricity) |
| AHB | MSCONS AHB |
| Transmission channel | AS4 |
This check identifier is used in 5 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 2 | Transmission of the delivery note for the grid usage settlement | NB → LF | Delivery note |
| GPKE part 4 | Business data request | MSB → LF | Response |
| WiM electricity part 2 | Processing and transmission of values from the MSB of the market location | MSB (corresponds to the MSB on the object market location) → NB | Value (market location / metering location) at NB |
| WiM electricity part 2 | Processing and transmission of values from the MSB of the market location | MSB (corresponds to the MSB on the object market location) → LF | Value (market location / metering location) at LF |
| GPKE part 4 | Business data request | MSB → NB | Response |
Transaction and responses
Role of this check identifier: response. Basis: the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 17102 | Request for values | ORDERS | from the step sequence |
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfrageReferenz | SG1.RFF+AGI | dokumentennummer |
RFF+AGI quotes the BGM of the request; the target is its dokumentennummer. Measured: 17102 carries dokumentennummer in BGM+[7|Z28|Z48].
Check identifiers of the same AHB table: No other check identifier of message type MSCONS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 145 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains 2 transactions for this check identifier under the message type mscons. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.