Check identifier 55063 — Deactivation of ZP
Check identifier 55063 · EDIFACT message type UTILMD · Format version 202604
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55063 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z0700070 | Activation/ deactivation of MaBiS-ZP | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00160 | Information contact | — | X | — |
341200170 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800180 | Number / address | — | X | (([939] [321]) ∨ ([940] [322])) ∧ [514] |
3155 EM00190 | Electronic mail | — | X | [1P0..1] |
3155 FX00200 | Fax number | — | X | [1P0..1] |
3155 TE00210 | Telephone | — | X | [1P0..1] |
3155 AJ00220 | further telephone | — | X | [1P0..1] |
3155 AL00230 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00240 | Message recipient | — | X | — |
303900250 | MP-ID | — | X | [280] |
3055 900260 | GS1 | — | X | — |
3055 29300270 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400280 | Transaction | — | X | — |
740200290 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 15900300 | End of balancing | — | X | — |
238000310 | Date or time or time span, value | — | X | [UB1] |
2379 30300320 | CCYYMMDDHHMMZZZ | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1500330 | MaBiS metering point | — | X | — |
322500340 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300350 | Check identifier | — | X | — |
1154 5506300360 | MaBiS / Deactivation of MaBiS-ZP | — | X | — |
| UNT | — | — | Must | — |
007400370 | Number of segments in a message | — | X | — |
006200380 | Message reference number | — | X | — |
Conditions of this table
The free text of the 11 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [280] | Only MP-ID from the electricity division |
| [321] | If code EM is present in DE3155 in the same COM |
| [322] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [931] | Format: ZZZ = +00 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [951] | Format: Metering point identifier |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, ÜNB, BIKO and BKV.
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Deactivation of ZP |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |
This check identifier is used in 18 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Deactivation of a MaBiS metering point for the grid time series | NB (responsible NB) → NB (neighbouring NB) | Deactivation of a MaBiS-ZP for the NZR |
| MaBiS | Deactivation of a MaBiS metering point for the grid time series | NB (responsible NB) → BIKO | Deactivation of a MaBiS-ZP for the NZR |
| MaBiS | Deactivation of a MaBiS metering point for the supplier aggregated time series from the NB to LF | NB → LF | Deactivation of a MaBiS-ZP for the LF-SZR (category A) |
| MaBiS | Deactivation of a MaBiS metering point for the supplier aggregated time series from the ÜNB to LF | ÜNB → LF | Deactivation of a MaBiS-ZP for the LF-SZR (category B) |
| MaBiS | Deactivation of a MaBiS metering point for the balancing area aggregate time series from the ÜNB to BIKO and NB | ÜNB → BIKO | Deactivation of a MaBiS-ZP for the BG-SZR (category B) |
| MaBiS | Deactivation of a MaBiS metering point for the balancing area aggregate time series from the ÜNB to BIKO and NB | BIKO → NB | Forwarding of the deactivation of the MaBiS-ZP for the BG-SZR (category B) |
| MaBiS | Deactivation of a MaBiS metering point for the balancing group aggregated time series from the NB to BIKO and BKV | NB → BIKO | Deactivation of a MaBiS-ZP for the BK-SZR (category A) |
| MaBiS | Deactivation of a MaBiS metering point for the balancing group aggregated time series from the NB to BIKO and BKV | BIKO → BKV | Forwarding of the deactivation of the MaBiS-ZP for the BK-SZR (category A) |
| MaBiS | Deactivation of a MaBiS metering point for the balancing group aggregated time series from the ÜNB to BIKO and BKV | ÜNB → BIKO | Deactivation of a MaBiS-ZP for BK-SZR (category B) |
| MaBiS | Deactivation of a MaBiS metering point for the balancing group aggregated time series from the ÜNB to BIKO and BKV | BIKO → BKV | Forwarding of the deactivation of the MaBiS-ZP for BK-SZR (category B) |
| MaBiS | Deactivation of a MaBiS metering point for the delta time series carry-over from the ÜNB to BIKO and NB | ÜNB → BIKO | Deactivation of a MaBiS-ZP for the DZÜ |
| MaBiS | Deactivation of a MaBiS metering point for the delta time series carry-over from the ÜNB to BIKO and NB | BIKO → NB | Forwarding of the deactivation of the MaBiS-ZP for the DZÜ |
| MaBiS | Deactivation of a MaBiS metering point for the settlement aggregated time series from BIKO to NB | BIKO → NB | Deactivation of a MaBiS-ZP for the NB-DZR |
| MaBiS | Deactivation of a MaBiS metering point for the settlement aggregated time series from the BIKO to BKV | BIKO → BKV | Deactivation of a MaBiS-ZP for the settlement aggregated time series |
| MaBiS | Deactivation of a MaBiS metering point for the settlement aggregated time series from the BIKO to ÜNB | BIKO → ÜNB | Deactivation of a MaBiS-ZP for the ÜNB-DZR |
| MaBiS | Deactivation of a MaBiS-ZP for the daily balancing area aggregate time series from the ÜNB to NB | ÜNB → NB | Deactivation of a MaBiS-ZP for the BG-SZR (category C) |
| MaBiS | Deactivation of a MaBiS-ZP for the daily balancing group aggregated time series from the ÜNB to BKV | ÜNB → BKV | Deactivation of a MaBiS-ZP for the BK-SZR (category C) |
| AWH Model 2 charg.-session-level bal. energy assign. option | Deactivation of a MaBiS metering point for the daily balancing group aggregated time series eMob from the NB (LPB) to ÜNB | NB (LPB) → ÜNB | Deactivation of a MaBiS-ZP for the daily BK-SZR eMob |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 50 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.