Check identifier 55622 — Response message/request for data of MaLo
Check identifier 55622 · EDIFACT message type UTILMD · format version 202604
Data structure
| Structure (BO4E) | Description | Format | 55622 | Condition |
|---|---|---|---|---|
| stammdaten | — | object | May | — |
| MARKTLOKATION [ ] | — | object[] | May | — |
| datenqualitaet 00010 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| fernsteuerbarkeit 00020 | Remote controllability | Enum Fernsteuerbarkeit | X | — |
TECHNISCH_NICHT_FERNSTEUERBAR | — | — | X | — |
TECHNISCH_FERNSTEUERBAR | — | — | X | — |
DURCH_LF_FERNSTEUERBAR | — | — | X | — |
| marktlokationsId 00030 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| messtechnischeEinordnung 00040 | Metering classification from the UTILMD (IMS, KME_MME, KEINE_MESSUNG) | Enum MesstechnischeEinordnung | Must | — |
IMS | — | — | Must | — |
KME_MME | — | — | Must | — |
KEINE_MESSUNG | — | — | Must | — |
| netzebene 00050 | Grid level at which the energy is drawn. For electricity, the voltage level of the supply; for gas, the pressure level. Example electricity: low voltage Example gas: low pressure. | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| redispatch 00060 | redispatch | boolean | X | — |
| statusErzeugendeMalo 00070 | Status of the generating market location | Enum StatusErzeugendeMarktlokation | X | — |
EINSPEISEVERGUETUNG_PARAGRAPH_37 | — | — | X | — |
GEFOERDERTE_DIREKTVERMARKTUNG | — | — | X | — |
SONSTIGE_DIREKTVERMARKTUNG | — | — | X | — |
VERMARKTUNG_OHNE_GESETZL_VERGUETUNG | — | — | X | — |
KWKG_VERGUETUNG | — | — | X | — |
EINSPEISEVERGUETUNG_PARAGRAPH_38_AUSFALLVERGUETUNG | — | — | X | — |
| umspannung 00080 | Grid level | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| verguetungEmpfaenger 00090 | Remuneration recipient | Enum VerguetungEmpfaenger | Must | — |
KUNDE | — | — | Must | — |
LIEFERANT | — | — | Must | — |
| eigentuemer | — | object | May | — |
| anrede 00100 | The form of address for the GePa, e.g. Mr. | string | Must | — |
| gewerbekennzeichnung 00110 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | Must | — |
| name1 00120 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | Must | — |
| name2 00130 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | Must | — |
| name3 00140 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | Must | — |
| name4 00150 | name4 | string | Must | — |
| partneradresse | — | object | May | — |
| hausnummer 00160 | House number and supplement | string | Must | — |
| landescode 00170 | Country code | Enum Landescode | Must | — |
AC | — | — | Must | — |
AD | — | — | Must | — |
AE | — | — | Must | — |
AF | — | — | Must | — |
AG | — | — | Must | — |
AI | — | — | Must | — |
AL | — | — | Must | — |
AM | — | — | Must | — |
AN | — | — | Must | — |
AO | — | — | Must | — |
AQ | — | — | Must | — |
AR | — | — | Must | — |
AS | — | — | Must | — |
AT | — | — | Must | — |
AU | — | — | Must | — |
AW | — | — | Must | — |
AX | — | — | Must | — |
AZ | — | — | Must | — |
BA | — | — | Must | — |
BB | — | — | Must | — |
BD | — | — | Must | — |
BE | — | — | Must | — |
BF | — | — | Must | — |
BG | — | — | Must | — |
BH | — | — | Must | — |
BI | — | — | Must | — |
BJ | — | — | Must | — |
BL | — | — | Must | — |
BM | — | — | Must | — |
BN | — | — | Must | — |
BO | — | — | Must | — |
BQ | — | — | Must | — |
BR | — | — | Must | — |
BS | — | — | Must | — |
BT | — | — | Must | — |
BU | — | — | Must | — |
BV | — | — | Must | — |
BW | — | — | Must | — |
BY | — | — | Must | — |
BZ | — | — | Must | — |
CA | — | — | Must | — |
CC | — | — | Must | — |
CD | — | — | Must | — |
CF | — | — | Must | — |
CG | — | — | Must | — |
CH | — | — | Must | — |
CI | — | — | Must | — |
CK | — | — | Must | — |
CL | — | — | Must | — |
CM | — | — | Must | — |
CN | — | — | Must | — |
CO | — | — | Must | — |
CP | — | — | Must | — |
CR | — | — | Must | — |
CS | — | — | Must | — |
CU | — | — | Must | — |
CV | — | — | Must | — |
CW | — | — | Must | — |
CX | — | — | Must | — |
CY | — | — | Must | — |
CZ | — | — | Must | — |
DE | — | — | Must | — |
DG | — | — | Must | — |
DJ | — | — | Must | — |
DK | — | — | Must | — |
DM | — | — | Must | — |
DO | — | — | Must | — |
DZ | — | — | Must | — |
EA | — | — | Must | — |
EC | — | — | Must | — |
EE | — | — | Must | — |
EG | — | — | Must | — |
EH | — | — | Must | — |
ER | — | — | Must | — |
ES | — | — | Must | — |
ET | — | — | Must | — |
EU | — | — | Must | — |
FI | — | — | Must | — |
FJ | — | — | Must | — |
FK | — | — | Must | — |
FM | — | — | Must | — |
FO | — | — | Must | — |
FR | — | — | Must | — |
FX | — | — | Must | — |
GA | — | — | Must | — |
GB | — | — | Must | — |
GD | — | — | Must | — |
GE | — | — | Must | — |
GF | — | — | Must | — |
GG | — | — | Must | — |
GH | — | — | Must | — |
GI | — | — | Must | — |
GL | — | — | Must | — |
GM | — | — | Must | — |
GN | — | — | Must | — |
GP | — | — | Must | — |
GQ | — | — | Must | — |
GR | — | — | Must | — |
GS | — | — | Must | — |
GT | — | — | Must | — |
GU | — | — | Must | — |
GW | — | — | Must | — |
GY | — | — | Must | — |
HK | — | — | Must | — |
HM | — | — | Must | — |
HN | — | — | Must | — |
HR | — | — | Must | — |
HT | — | — | Must | — |
HU | — | — | Must | — |
IC | — | — | Must | — |
ID | — | — | Must | — |
IE | — | — | Must | — |
IL | — | — | Must | — |
IM | — | — | Must | — |
IN | — | — | Must | — |
IO | — | — | Must | — |
IQ | — | — | Must | — |
IR | — | — | Must | — |
IS | — | — | Must | — |
IT | — | — | Must | — |
JE | — | — | Must | — |
JM | — | — | Must | — |
JO | — | — | Must | — |
JP | — | — | Must | — |
KE | — | — | Must | — |
KG | — | — | Must | — |
KH | — | — | Must | — |
KI | — | — | Must | — |
KM | — | — | Must | — |
KN | — | — | Must | — |
KP | — | — | Must | — |
KR | — | — | Must | — |
KW | — | — | Must | — |
KY | — | — | Must | — |
KZ | — | — | Must | — |
LA | — | — | Must | — |
LB | — | — | Must | — |
LC | — | — | Must | — |
LI | — | — | Must | — |
LK | — | — | Must | — |
LR | — | — | Must | — |
LS | — | — | Must | — |
LT | — | — | Must | — |
LU | — | — | Must | — |
LV | — | — | Must | — |
LY | — | — | Must | — |
MA | — | — | Must | — |
MC | — | — | Must | — |
MD | — | — | Must | — |
ME | — | — | Must | — |
MF | — | — | Must | — |
MG | — | — | Must | — |
MH | — | — | Must | — |
MK | — | — | Must | — |
ML | — | — | Must | — |
MM | — | — | Must | — |
MN | — | — | Must | — |
MO | — | — | Must | — |
MP | — | — | Must | — |
MQ | — | — | Must | — |
MR | — | — | Must | — |
MS | — | — | Must | — |
MT | — | — | Must | — |
MU | — | — | Must | — |
MV | — | — | Must | — |
MW | — | — | Must | — |
MX | — | — | Must | — |
MY | — | — | Must | — |
MZ | — | — | Must | — |
NA | — | — | Must | — |
NC | — | — | Must | — |
NE | — | — | Must | — |
NF | — | — | Must | — |
NG | — | — | Must | — |
NI | — | — | Must | — |
NL | — | — | Must | — |
NO | — | — | Must | — |
NP | — | — | Must | — |
NR | — | — | Must | — |
NT | — | — | Must | — |
NU | — | — | Must | — |
NZ | — | — | Must | — |
OM | — | — | Must | — |
PA | — | — | Must | — |
PE | — | — | Must | — |
PF | — | — | Must | — |
PG | — | — | Must | — |
PH | — | — | Must | — |
PK | — | — | Must | — |
PL | — | — | Must | — |
PM | — | — | Must | — |
PN | — | — | Must | — |
PR | — | — | Must | — |
PS | — | — | Must | — |
PT | — | — | Must | — |
PW | — | — | Must | — |
PY | — | — | Must | — |
QA | — | — | Must | — |
RE | — | — | Must | — |
RO | — | — | Must | — |
RS | — | — | Must | — |
RU | — | — | Must | — |
RW | — | — | Must | — |
SA | — | — | Must | — |
SB | — | — | Must | — |
SC | — | — | Must | — |
SD | — | — | Must | — |
SE | — | — | Must | — |
SF | — | — | Must | — |
SG | — | — | Must | — |
SH | — | — | Must | — |
SI | — | — | Must | — |
SJ | — | — | Must | — |
SK | — | — | Must | — |
SL | — | — | Must | — |
SM | — | — | Must | — |
SN | — | — | Must | — |
SO | — | — | Must | — |
SR | — | — | Must | — |
SS | — | — | Must | — |
ST | — | — | Must | — |
SU | — | — | Must | — |
SV | — | — | Must | — |
SX | — | — | Must | — |
SY | — | — | Must | — |
SZ | — | — | Must | — |
TA | — | — | Must | — |
TC | — | — | Must | — |
TD | — | — | Must | — |
TF | — | — | Must | — |
TG | — | — | Must | — |
TJ | — | — | Must | — |
TK | — | — | Must | — |
TL | — | — | Must | — |
TM | — | — | Must | — |
TN | — | — | Must | — |
TO | — | — | Must | — |
TP | — | — | Must | — |
TR | — | — | Must | — |
TT | — | — | Must | — |
TV | — | — | Must | — |
TW | — | — | Must | — |
TZ | — | — | Must | — |
UA | — | — | Must | — |
UG | — | — | Must | — |
UK | — | — | Must | — |
UM | — | — | Must | — |
US | — | — | Must | — |
UY | — | — | Must | — |
UZ | — | — | Must | — |
VA | — | — | Must | — |
VC | — | — | Must | — |
VE | — | — | Must | — |
VG | — | — | Must | — |
VI | — | — | Must | — |
VN | — | — | Must | — |
VU | — | — | Must | — |
WF | — | — | Must | — |
WS | — | — | Must | — |
XK | — | — | Must | — |
YE | — | — | Must | — |
YT | — | — | Must | — |
YU | — | — | Must | — |
ZA | — | — | Must | — |
ZM | — | — | Must | — |
ZR | — | — | Must | — |
ZW | — | — | Must | — |
| ort 00180 | City | string | Must | — |
| ortsteil 00190 | District | string | Must | — |
| postfach 00200 | PO box | string | Must | — |
| postleitzahl 00210 | Postal code | string | Must | — |
| strasse 00220 | Street | string | Must | — |
| energieherkunft [ ] | — | object[] | May | — |
| erzeugungsart 00230 | Type of generation | Enum Erzeugungsart | Must | — |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| gueltigkeitszeitraum | — | object | May | — |
| zeitraumId 00240 | zeitraumId | integer | X | — |
| hausverwalter | — | object | May | — |
| anrede 00250 | The form of address for the GePa, e.g. Mr. | string | Must | — |
| gewerbekennzeichnung 00260 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | Must | — |
| name1 00270 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | Must | — |
| name2 00280 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | Must | — |
| name3 00290 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | Must | — |
| name4 00300 | name4 | string | Must | — |
| partneradresse | — | object | May | — |
| hausnummer 00310 | House number and supplement | string | Must | — |
| landescode 00320 | Country code | Enum Landescode | Must | — |
AC | — | — | Must | — |
AD | — | — | Must | — |
AE | — | — | Must | — |
AF | — | — | Must | — |
AG | — | — | Must | — |
AI | — | — | Must | — |
AL | — | — | Must | — |
AM | — | — | Must | — |
AN | — | — | Must | — |
AO | — | — | Must | — |
AQ | — | — | Must | — |
AR | — | — | Must | — |
AS | — | — | Must | — |
AT | — | — | Must | — |
AU | — | — | Must | — |
AW | — | — | Must | — |
AX | — | — | Must | — |
AZ | — | — | Must | — |
BA | — | — | Must | — |
BB | — | — | Must | — |
BD | — | — | Must | — |
BE | — | — | Must | — |
BF | — | — | Must | — |
BG | — | — | Must | — |
BH | — | — | Must | — |
BI | — | — | Must | — |
BJ | — | — | Must | — |
BL | — | — | Must | — |
BM | — | — | Must | — |
BN | — | — | Must | — |
BO | — | — | Must | — |
BQ | — | — | Must | — |
BR | — | — | Must | — |
BS | — | — | Must | — |
BT | — | — | Must | — |
BU | — | — | Must | — |
BV | — | — | Must | — |
BW | — | — | Must | — |
BY | — | — | Must | — |
BZ | — | — | Must | — |
CA | — | — | Must | — |
CC | — | — | Must | — |
CD | — | — | Must | — |
CF | — | — | Must | — |
CG | — | — | Must | — |
CH | — | — | Must | — |
CI | — | — | Must | — |
CK | — | — | Must | — |
CL | — | — | Must | — |
CM | — | — | Must | — |
CN | — | — | Must | — |
CO | — | — | Must | — |
CP | — | — | Must | — |
CR | — | — | Must | — |
CS | — | — | Must | — |
CU | — | — | Must | — |
CV | — | — | Must | — |
CW | — | — | Must | — |
CX | — | — | Must | — |
CY | — | — | Must | — |
CZ | — | — | Must | — |
DE | — | — | Must | — |
DG | — | — | Must | — |
DJ | — | — | Must | — |
DK | — | — | Must | — |
DM | — | — | Must | — |
DO | — | — | Must | — |
DZ | — | — | Must | — |
EA | — | — | Must | — |
EC | — | — | Must | — |
EE | — | — | Must | — |
EG | — | — | Must | — |
EH | — | — | Must | — |
ER | — | — | Must | — |
ES | — | — | Must | — |
ET | — | — | Must | — |
EU | — | — | Must | — |
FI | — | — | Must | — |
FJ | — | — | Must | — |
FK | — | — | Must | — |
FM | — | — | Must | — |
FO | — | — | Must | — |
FR | — | — | Must | — |
FX | — | — | Must | — |
GA | — | — | Must | — |
GB | — | — | Must | — |
GD | — | — | Must | — |
GE | — | — | Must | — |
GF | — | — | Must | — |
GG | — | — | Must | — |
GH | — | — | Must | — |
GI | — | — | Must | — |
GL | — | — | Must | — |
GM | — | — | Must | — |
GN | — | — | Must | — |
GP | — | — | Must | — |
GQ | — | — | Must | — |
GR | — | — | Must | — |
GS | — | — | Must | — |
GT | — | — | Must | — |
GU | — | — | Must | — |
GW | — | — | Must | — |
GY | — | — | Must | — |
HK | — | — | Must | — |
HM | — | — | Must | — |
HN | — | — | Must | — |
HR | — | — | Must | — |
HT | — | — | Must | — |
HU | — | — | Must | — |
IC | — | — | Must | — |
ID | — | — | Must | — |
IE | — | — | Must | — |
IL | — | — | Must | — |
IM | — | — | Must | — |
IN | — | — | Must | — |
IO | — | — | Must | — |
IQ | — | — | Must | — |
IR | — | — | Must | — |
IS | — | — | Must | — |
IT | — | — | Must | — |
JE | — | — | Must | — |
JM | — | — | Must | — |
JO | — | — | Must | — |
JP | — | — | Must | — |
KE | — | — | Must | — |
KG | — | — | Must | — |
KH | — | — | Must | — |
KI | — | — | Must | — |
KM | — | — | Must | — |
KN | — | — | Must | — |
KP | — | — | Must | — |
KR | — | — | Must | — |
KW | — | — | Must | — |
KY | — | — | Must | — |
KZ | — | — | Must | — |
LA | — | — | Must | — |
LB | — | — | Must | — |
LC | — | — | Must | — |
LI | — | — | Must | — |
LK | — | — | Must | — |
LR | — | — | Must | — |
LS | — | — | Must | — |
LT | — | — | Must | — |
LU | — | — | Must | — |
LV | — | — | Must | — |
LY | — | — | Must | — |
MA | — | — | Must | — |
MC | — | — | Must | — |
MD | — | — | Must | — |
ME | — | — | Must | — |
MF | — | — | Must | — |
MG | — | — | Must | — |
MH | — | — | Must | — |
MK | — | — | Must | — |
ML | — | — | Must | — |
MM | — | — | Must | — |
MN | — | — | Must | — |
MO | — | — | Must | — |
MP | — | — | Must | — |
MQ | — | — | Must | — |
MR | — | — | Must | — |
MS | — | — | Must | — |
MT | — | — | Must | — |
MU | — | — | Must | — |
MV | — | — | Must | — |
MW | — | — | Must | — |
MX | — | — | Must | — |
MY | — | — | Must | — |
MZ | — | — | Must | — |
NA | — | — | Must | — |
NC | — | — | Must | — |
NE | — | — | Must | — |
NF | — | — | Must | — |
NG | — | — | Must | — |
NI | — | — | Must | — |
NL | — | — | Must | — |
NO | — | — | Must | — |
NP | — | — | Must | — |
NR | — | — | Must | — |
NT | — | — | Must | — |
NU | — | — | Must | — |
NZ | — | — | Must | — |
OM | — | — | Must | — |
PA | — | — | Must | — |
PE | — | — | Must | — |
PF | — | — | Must | — |
PG | — | — | Must | — |
PH | — | — | Must | — |
PK | — | — | Must | — |
PL | — | — | Must | — |
PM | — | — | Must | — |
PN | — | — | Must | — |
PR | — | — | Must | — |
PS | — | — | Must | — |
PT | — | — | Must | — |
PW | — | — | Must | — |
PY | — | — | Must | — |
QA | — | — | Must | — |
RE | — | — | Must | — |
RO | — | — | Must | — |
RS | — | — | Must | — |
RU | — | — | Must | — |
RW | — | — | Must | — |
SA | — | — | Must | — |
SB | — | — | Must | — |
SC | — | — | Must | — |
SD | — | — | Must | — |
SE | — | — | Must | — |
SF | — | — | Must | — |
SG | — | — | Must | — |
SH | — | — | Must | — |
SI | — | — | Must | — |
SJ | — | — | Must | — |
SK | — | — | Must | — |
SL | — | — | Must | — |
SM | — | — | Must | — |
SN | — | — | Must | — |
SO | — | — | Must | — |
SR | — | — | Must | — |
SS | — | — | Must | — |
ST | — | — | Must | — |
SU | — | — | Must | — |
SV | — | — | Must | — |
SX | — | — | Must | — |
SY | — | — | Must | — |
SZ | — | — | Must | — |
TA | — | — | Must | — |
TC | — | — | Must | — |
TD | — | — | Must | — |
TF | — | — | Must | — |
TG | — | — | Must | — |
TJ | — | — | Must | — |
TK | — | — | Must | — |
TL | — | — | Must | — |
TM | — | — | Must | — |
TN | — | — | Must | — |
TO | — | — | Must | — |
TP | — | — | Must | — |
TR | — | — | Must | — |
TT | — | — | Must | — |
TV | — | — | Must | — |
TW | — | — | Must | — |
TZ | — | — | Must | — |
UA | — | — | Must | — |
UG | — | — | Must | — |
UK | — | — | Must | — |
UM | — | — | Must | — |
US | — | — | Must | — |
UY | — | — | Must | — |
UZ | — | — | Must | — |
VA | — | — | Must | — |
VC | — | — | Must | — |
VE | — | — | Must | — |
VG | — | — | Must | — |
VI | — | — | Must | — |
VN | — | — | Must | — |
VU | — | — | Must | — |
WF | — | — | Must | — |
WS | — | — | Must | — |
XK | — | — | Must | — |
YE | — | — | Must | — |
YT | — | — | Must | — |
YU | — | — | Must | — |
ZA | — | — | Must | — |
ZM | — | — | Must | — |
ZR | — | — | Must | — |
ZW | — | — | Must | — |
| ort 00330 | City | string | Must | — |
| ortsteil 00340 | District | string | Must | — |
| postfach 00350 | PO box | string | Must | — |
| postleitzahl 00360 | Postal code | string | Must | — |
| strasse 00370 | Street | string | Must | — |
| lokationsadresse | — | object | May | — |
| hausnummer 00380 | House number and supplement | string | Must | — |
| landescode 00390 | Country code | Enum Landescode | Must | — |
AC | — | — | Must | — |
AD | — | — | Must | — |
AE | — | — | Must | — |
AF | — | — | Must | — |
AG | — | — | Must | — |
AI | — | — | Must | — |
AL | — | — | Must | — |
AM | — | — | Must | — |
AN | — | — | Must | — |
AO | — | — | Must | — |
AQ | — | — | Must | — |
AR | — | — | Must | — |
AS | — | — | Must | — |
AT | — | — | Must | — |
AU | — | — | Must | — |
AW | — | — | Must | — |
AX | — | — | Must | — |
AZ | — | — | Must | — |
BA | — | — | Must | — |
BB | — | — | Must | — |
BD | — | — | Must | — |
BE | — | — | Must | — |
BF | — | — | Must | — |
BG | — | — | Must | — |
BH | — | — | Must | — |
BI | — | — | Must | — |
BJ | — | — | Must | — |
BL | — | — | Must | — |
BM | — | — | Must | — |
BN | — | — | Must | — |
BO | — | — | Must | — |
BQ | — | — | Must | — |
BR | — | — | Must | — |
BS | — | — | Must | — |
BT | — | — | Must | — |
BU | — | — | Must | — |
BV | — | — | Must | — |
BW | — | — | Must | — |
BY | — | — | Must | — |
BZ | — | — | Must | — |
CA | — | — | Must | — |
CC | — | — | Must | — |
CD | — | — | Must | — |
CF | — | — | Must | — |
CG | — | — | Must | — |
CH | — | — | Must | — |
CI | — | — | Must | — |
CK | — | — | Must | — |
CL | — | — | Must | — |
CM | — | — | Must | — |
CN | — | — | Must | — |
CO | — | — | Must | — |
CP | — | — | Must | — |
CR | — | — | Must | — |
CS | — | — | Must | — |
CU | — | — | Must | — |
CV | — | — | Must | — |
CW | — | — | Must | — |
CX | — | — | Must | — |
CY | — | — | Must | — |
CZ | — | — | Must | — |
DE | — | — | Must | — |
DG | — | — | Must | — |
DJ | — | — | Must | — |
DK | — | — | Must | — |
DM | — | — | Must | — |
DO | — | — | Must | — |
DZ | — | — | Must | — |
EA | — | — | Must | — |
EC | — | — | Must | — |
EE | — | — | Must | — |
EG | — | — | Must | — |
EH | — | — | Must | — |
ER | — | — | Must | — |
ES | — | — | Must | — |
ET | — | — | Must | — |
EU | — | — | Must | — |
FI | — | — | Must | — |
FJ | — | — | Must | — |
FK | — | — | Must | — |
FM | — | — | Must | — |
FO | — | — | Must | — |
FR | — | — | Must | — |
FX | — | — | Must | — |
GA | — | — | Must | — |
GB | — | — | Must | — |
GD | — | — | Must | — |
GE | — | — | Must | — |
GF | — | — | Must | — |
GG | — | — | Must | — |
GH | — | — | Must | — |
GI | — | — | Must | — |
GL | — | — | Must | — |
GM | — | — | Must | — |
GN | — | — | Must | — |
GP | — | — | Must | — |
GQ | — | — | Must | — |
GR | — | — | Must | — |
GS | — | — | Must | — |
GT | — | — | Must | — |
GU | — | — | Must | — |
GW | — | — | Must | — |
GY | — | — | Must | — |
HK | — | — | Must | — |
HM | — | — | Must | — |
HN | — | — | Must | — |
HR | — | — | Must | — |
HT | — | — | Must | — |
HU | — | — | Must | — |
IC | — | — | Must | — |
ID | — | — | Must | — |
IE | — | — | Must | — |
IL | — | — | Must | — |
IM | — | — | Must | — |
IN | — | — | Must | — |
IO | — | — | Must | — |
IQ | — | — | Must | — |
IR | — | — | Must | — |
IS | — | — | Must | — |
IT | — | — | Must | — |
JE | — | — | Must | — |
JM | — | — | Must | — |
JO | — | — | Must | — |
JP | — | — | Must | — |
KE | — | — | Must | — |
KG | — | — | Must | — |
KH | — | — | Must | — |
KI | — | — | Must | — |
KM | — | — | Must | — |
KN | — | — | Must | — |
KP | — | — | Must | — |
KR | — | — | Must | — |
KW | — | — | Must | — |
KY | — | — | Must | — |
KZ | — | — | Must | — |
LA | — | — | Must | — |
LB | — | — | Must | — |
LC | — | — | Must | — |
LI | — | — | Must | — |
LK | — | — | Must | — |
LR | — | — | Must | — |
LS | — | — | Must | — |
LT | — | — | Must | — |
LU | — | — | Must | — |
LV | — | — | Must | — |
LY | — | — | Must | — |
MA | — | — | Must | — |
MC | — | — | Must | — |
MD | — | — | Must | — |
ME | — | — | Must | — |
MF | — | — | Must | — |
MG | — | — | Must | — |
MH | — | — | Must | — |
MK | — | — | Must | — |
ML | — | — | Must | — |
MM | — | — | Must | — |
MN | — | — | Must | — |
MO | — | — | Must | — |
MP | — | — | Must | — |
MQ | — | — | Must | — |
MR | — | — | Must | — |
MS | — | — | Must | — |
MT | — | — | Must | — |
MU | — | — | Must | — |
MV | — | — | Must | — |
MW | — | — | Must | — |
MX | — | — | Must | — |
MY | — | — | Must | — |
MZ | — | — | Must | — |
NA | — | — | Must | — |
NC | — | — | Must | — |
NE | — | — | Must | — |
NF | — | — | Must | — |
NG | — | — | Must | — |
NI | — | — | Must | — |
NL | — | — | Must | — |
NO | — | — | Must | — |
NP | — | — | Must | — |
NR | — | — | Must | — |
NT | — | — | Must | — |
NU | — | — | Must | — |
NZ | — | — | Must | — |
OM | — | — | Must | — |
PA | — | — | Must | — |
PE | — | — | Must | — |
PF | — | — | Must | — |
PG | — | — | Must | — |
PH | — | — | Must | — |
PK | — | — | Must | — |
PL | — | — | Must | — |
PM | — | — | Must | — |
PN | — | — | Must | — |
PR | — | — | Must | — |
PS | — | — | Must | — |
PT | — | — | Must | — |
PW | — | — | Must | — |
PY | — | — | Must | — |
QA | — | — | Must | — |
RE | — | — | Must | — |
RO | — | — | Must | — |
RS | — | — | Must | — |
RU | — | — | Must | — |
RW | — | — | Must | — |
SA | — | — | Must | — |
SB | — | — | Must | — |
SC | — | — | Must | — |
SD | — | — | Must | — |
SE | — | — | Must | — |
SF | — | — | Must | — |
SG | — | — | Must | — |
SH | — | — | Must | — |
SI | — | — | Must | — |
SJ | — | — | Must | — |
SK | — | — | Must | — |
SL | — | — | Must | — |
SM | — | — | Must | — |
SN | — | — | Must | — |
SO | — | — | Must | — |
SR | — | — | Must | — |
SS | — | — | Must | — |
ST | — | — | Must | — |
SU | — | — | Must | — |
SV | — | — | Must | — |
SX | — | — | Must | — |
SY | — | — | Must | — |
SZ | — | — | Must | — |
TA | — | — | Must | — |
TC | — | — | Must | — |
TD | — | — | Must | — |
TF | — | — | Must | — |
TG | — | — | Must | — |
TJ | — | — | Must | — |
TK | — | — | Must | — |
TL | — | — | Must | — |
TM | — | — | Must | — |
TN | — | — | Must | — |
TO | — | — | Must | — |
TP | — | — | Must | — |
TR | — | — | Must | — |
TT | — | — | Must | — |
TV | — | — | Must | — |
TW | — | — | Must | — |
TZ | — | — | Must | — |
UA | — | — | Must | — |
UG | — | — | Must | — |
UK | — | — | Must | — |
UM | — | — | Must | — |
US | — | — | Must | — |
UY | — | — | Must | — |
UZ | — | — | Must | — |
VA | — | — | Must | — |
VC | — | — | Must | — |
VE | — | — | Must | — |
VG | — | — | Must | — |
VI | — | — | Must | — |
VN | — | — | Must | — |
VU | — | — | Must | — |
WF | — | — | Must | — |
WS | — | — | Must | — |
XK | — | — | Must | — |
YE | — | — | Must | — |
YT | — | — | Must | — |
YU | — | — | Must | — |
ZA | — | — | Must | — |
ZM | — | — | Must | — |
ZR | — | — | Must | — |
ZW | — | — | Must | — |
| ort 00400 | City | string | Must | — |
| ortsteil 00410 | District | string | Must | — |
| postfach 00420 | PO box | string | Must | — |
| postleitzahl 00430 | Postal code | string | Must | — |
| strasse 00440 | Street | string | Must | — |
| zusatzInformation | — | object | May | — |
| zusatz1 00450 | Address supplement 1 | string | Must | — |
| zusatz2 00460 | Address supplement 2 | string | Must | — |
| zusatz3 00470 | Address supplement 3 | string | Must | — |
| zusatz4 00480 | Address supplement 4 | string | Must | — |
| zusatz5 00490 | Address supplement 5 | string | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00500 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00510 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00520 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00530 | weiterverpflichtet | boolean | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| artEMobilitaet 00540 | ArtEmobilitaet | Enum ArtEmobilitaet | Must | — |
WB | — | — | Must | — |
LS | — | — | Must | — |
LP | — | — | Must | — |
| obisKennzahl 00550 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| unterbrechbarkeit 00560 | Electricity consumption type / interruptibility market location | Enum Unterbrechbarkeit | Must | — |
UV | — | — | Must | — |
NUV | — | — | Must | — |
| verbrauchsart 00570 | Electricity consumption type/consumption type market location | array | Must | — |
| waermenutzung 00580 | Electricity consumption type / heat use market location | Enum Waermenutzung | Must | — |
SPEICHERHEIZUNG | — | — | Must | — |
WAERMEPUMPE | — | — | Must | — |
DIREKTHEIZUNG | — | — | Must | — |
WAERMEPUMPE_WAERME_KAELTE | — | — | Must | — |
WAERMEPUMPE_KAELTE | — | — | Must | — |
WAERMEPUMPE_WAERME | — | — | Must | — |
| NETZNUTZUNGSVERTRAG [ ] | — | object[] | May | — |
| datenqualitaet 00590 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| gueltigkeitszeitraum | — | object | May | — |
| zeitraumId 00600 | zeitraumId | integer | X | — |
| korrespondenzpartner | — | object | May | — |
| anrede 00610 | The form of address for the GePa, e.g. Mr. | string | Must | — |
| name1 00620 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | Must | — |
| name2 00630 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | Must | — |
| name3 00640 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | Must | — |
| name4 00650 | name4 | string | Must | — |
| partneradresse | — | object | May | — |
| hausnummer 00660 | House number and supplement | string | Must | — |
| landescode 00670 | Country code | Enum Landescode | Must | — |
AC | — | — | Must | — |
AD | — | — | Must | — |
AE | — | — | Must | — |
AF | — | — | Must | — |
AG | — | — | Must | — |
AI | — | — | Must | — |
AL | — | — | Must | — |
AM | — | — | Must | — |
AN | — | — | Must | — |
AO | — | — | Must | — |
AQ | — | — | Must | — |
AR | — | — | Must | — |
AS | — | — | Must | — |
AT | — | — | Must | — |
AU | — | — | Must | — |
AW | — | — | Must | — |
AX | — | — | Must | — |
AZ | — | — | Must | — |
BA | — | — | Must | — |
BB | — | — | Must | — |
BD | — | — | Must | — |
BE | — | — | Must | — |
BF | — | — | Must | — |
BG | — | — | Must | — |
BH | — | — | Must | — |
BI | — | — | Must | — |
BJ | — | — | Must | — |
BL | — | — | Must | — |
BM | — | — | Must | — |
BN | — | — | Must | — |
BO | — | — | Must | — |
BQ | — | — | Must | — |
BR | — | — | Must | — |
BS | — | — | Must | — |
BT | — | — | Must | — |
BU | — | — | Must | — |
BV | — | — | Must | — |
BW | — | — | Must | — |
BY | — | — | Must | — |
BZ | — | — | Must | — |
CA | — | — | Must | — |
CC | — | — | Must | — |
CD | — | — | Must | — |
CF | — | — | Must | — |
CG | — | — | Must | — |
CH | — | — | Must | — |
CI | — | — | Must | — |
CK | — | — | Must | — |
CL | — | — | Must | — |
CM | — | — | Must | — |
CN | — | — | Must | — |
CO | — | — | Must | — |
CP | — | — | Must | — |
CR | — | — | Must | — |
CS | — | — | Must | — |
CU | — | — | Must | — |
CV | — | — | Must | — |
CW | — | — | Must | — |
CX | — | — | Must | — |
CY | — | — | Must | — |
CZ | — | — | Must | — |
DE | — | — | Must | — |
DG | — | — | Must | — |
DJ | — | — | Must | — |
DK | — | — | Must | — |
DM | — | — | Must | — |
DO | — | — | Must | — |
DZ | — | — | Must | — |
EA | — | — | Must | — |
EC | — | — | Must | — |
EE | — | — | Must | — |
EG | — | — | Must | — |
EH | — | — | Must | — |
ER | — | — | Must | — |
ES | — | — | Must | — |
ET | — | — | Must | — |
EU | — | — | Must | — |
FI | — | — | Must | — |
FJ | — | — | Must | — |
FK | — | — | Must | — |
FM | — | — | Must | — |
FO | — | — | Must | — |
FR | — | — | Must | — |
FX | — | — | Must | — |
GA | — | — | Must | — |
GB | — | — | Must | — |
GD | — | — | Must | — |
GE | — | — | Must | — |
GF | — | — | Must | — |
GG | — | — | Must | — |
GH | — | — | Must | — |
GI | — | — | Must | — |
GL | — | — | Must | — |
GM | — | — | Must | — |
GN | — | — | Must | — |
GP | — | — | Must | — |
GQ | — | — | Must | — |
GR | — | — | Must | — |
GS | — | — | Must | — |
GT | — | — | Must | — |
GU | — | — | Must | — |
GW | — | — | Must | — |
GY | — | — | Must | — |
HK | — | — | Must | — |
HM | — | — | Must | — |
HN | — | — | Must | — |
HR | — | — | Must | — |
HT | — | — | Must | — |
HU | — | — | Must | — |
IC | — | — | Must | — |
ID | — | — | Must | — |
IE | — | — | Must | — |
IL | — | — | Must | — |
IM | — | — | Must | — |
IN | — | — | Must | — |
IO | — | — | Must | — |
IQ | — | — | Must | — |
IR | — | — | Must | — |
IS | — | — | Must | — |
IT | — | — | Must | — |
JE | — | — | Must | — |
JM | — | — | Must | — |
JO | — | — | Must | — |
JP | — | — | Must | — |
KE | — | — | Must | — |
KG | — | — | Must | — |
KH | — | — | Must | — |
KI | — | — | Must | — |
KM | — | — | Must | — |
KN | — | — | Must | — |
KP | — | — | Must | — |
KR | — | — | Must | — |
KW | — | — | Must | — |
KY | — | — | Must | — |
KZ | — | — | Must | — |
LA | — | — | Must | — |
LB | — | — | Must | — |
LC | — | — | Must | — |
LI | — | — | Must | — |
LK | — | — | Must | — |
LR | — | — | Must | — |
LS | — | — | Must | — |
LT | — | — | Must | — |
LU | — | — | Must | — |
LV | — | — | Must | — |
LY | — | — | Must | — |
MA | — | — | Must | — |
MC | — | — | Must | — |
MD | — | — | Must | — |
ME | — | — | Must | — |
MF | — | — | Must | — |
MG | — | — | Must | — |
MH | — | — | Must | — |
MK | — | — | Must | — |
ML | — | — | Must | — |
MM | — | — | Must | — |
MN | — | — | Must | — |
MO | — | — | Must | — |
MP | — | — | Must | — |
MQ | — | — | Must | — |
MR | — | — | Must | — |
MS | — | — | Must | — |
MT | — | — | Must | — |
MU | — | — | Must | — |
MV | — | — | Must | — |
MW | — | — | Must | — |
MX | — | — | Must | — |
MY | — | — | Must | — |
MZ | — | — | Must | — |
NA | — | — | Must | — |
NC | — | — | Must | — |
NE | — | — | Must | — |
NF | — | — | Must | — |
NG | — | — | Must | — |
NI | — | — | Must | — |
NL | — | — | Must | — |
NO | — | — | Must | — |
NP | — | — | Must | — |
NR | — | — | Must | — |
NT | — | — | Must | — |
NU | — | — | Must | — |
NZ | — | — | Must | — |
OM | — | — | Must | — |
PA | — | — | Must | — |
PE | — | — | Must | — |
PF | — | — | Must | — |
PG | — | — | Must | — |
PH | — | — | Must | — |
PK | — | — | Must | — |
PL | — | — | Must | — |
PM | — | — | Must | — |
PN | — | — | Must | — |
PR | — | — | Must | — |
PS | — | — | Must | — |
PT | — | — | Must | — |
PW | — | — | Must | — |
PY | — | — | Must | — |
QA | — | — | Must | — |
RE | — | — | Must | — |
RO | — | — | Must | — |
RS | — | — | Must | — |
RU | — | — | Must | — |
RW | — | — | Must | — |
SA | — | — | Must | — |
SB | — | — | Must | — |
SC | — | — | Must | — |
SD | — | — | Must | — |
SE | — | — | Must | — |
SF | — | — | Must | — |
SG | — | — | Must | — |
SH | — | — | Must | — |
SI | — | — | Must | — |
SJ | — | — | Must | — |
SK | — | — | Must | — |
SL | — | — | Must | — |
SM | — | — | Must | — |
SN | — | — | Must | — |
SO | — | — | Must | — |
SR | — | — | Must | — |
SS | — | — | Must | — |
ST | — | — | Must | — |
SU | — | — | Must | — |
SV | — | — | Must | — |
SX | — | — | Must | — |
SY | — | — | Must | — |
SZ | — | — | Must | — |
TA | — | — | Must | — |
TC | — | — | Must | — |
TD | — | — | Must | — |
TF | — | — | Must | — |
TG | — | — | Must | — |
TJ | — | — | Must | — |
TK | — | — | Must | — |
TL | — | — | Must | — |
TM | — | — | Must | — |
TN | — | — | Must | — |
TO | — | — | Must | — |
TP | — | — | Must | — |
TR | — | — | Must | — |
TT | — | — | Must | — |
TV | — | — | Must | — |
TW | — | — | Must | — |
TZ | — | — | Must | — |
UA | — | — | Must | — |
UG | — | — | Must | — |
UK | — | — | Must | — |
UM | — | — | Must | — |
US | — | — | Must | — |
UY | — | — | Must | — |
UZ | — | — | Must | — |
VA | — | — | Must | — |
VC | — | — | Must | — |
VE | — | — | Must | — |
VG | — | — | Must | — |
VI | — | — | Must | — |
VN | — | — | Must | — |
VU | — | — | Must | — |
WF | — | — | Must | — |
WS | — | — | Must | — |
XK | — | — | Must | — |
YE | — | — | Must | — |
YT | — | — | Must | — |
YU | — | — | Must | — |
ZA | — | — | Must | — |
ZM | — | — | Must | — |
ZR | — | — | Must | — |
ZW | — | — | Must | — |
| ort 00680 | City | string | Must | — |
| ortsteil 00690 | District | string | Must | — |
| postfach 00700 | PO box | string | Must | — |
| postleitzahl 00710 | Postal code | string | Must | — |
| strasse 00720 | Street | string | Must | — |
| vertragspartner2 [ ] | — | object[] | May | — |
| anrede 00730 | The form of address for the GePa, e.g. Mr. | string | Must | — |
| geschaeftspartnerrolle 00740 | Role held by the business partner (e.g. prospect, customer). | array | Must | — |
| name1 00750 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | Must | — |
| name2 00760 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | Must | — |
| name3 00770 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | Must | — |
| name4 00780 | name4 | string | Must | — |
| VERWENDUNGSZEITRAUM [ ] | — | object[] | May | — |
| datenqualitaet 00790 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| verwendungAb 00800 | verwendungAb | string (date-time) | X | — |
| verwendungBis 00810 | verwendungBis | string (date-time) | X | — |
| zeitraumId 00820 | zeitraumId | integer | Must | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer 00830 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| dokumentennummer * 00840 | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| kategorie * 00850 | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| nachrichtendatum * 00860 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00870 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00880 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 00890 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| transaktionsgrundergaenzung * 00900 | Supplement to the transaction reason / UTILMD STS+7++E01+###+E03 | string | X | — |
| vorgangsnummer * 00910 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00920 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00930 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00940 | Email address | string | Must | — |
| nachname 00950 | Surname (family name) of the contact person | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00960 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00970 | rufnummer | string | Must | — |
| antwortStatusZeitraum [ ] | — | object[] | May | — |
| code 00980 | code | string | X | — |
| liste 00990 | liste | string | X | — |
| zeitraumId 01000 | zeitraumId | integer | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 01010 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 01020 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55622 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0300070 | Change notifications | — | X | [705] |
1001 Z8800080 | Request for data clearing | — | X | [706] |
100400090 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700100 | Document-/message date/time | — | X | — |
238000110 | Date or time or time span, value | — | X | [931] [494] |
2379 30300120 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00130 | Document-/message sender or sender | — | X | — |
303900140 | MP-ID | — | X | — |
3055 900150 | GS1 | — | X | — |
3055 29300160 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00170 | Information contact | — | X | — |
341200180 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800190 | Number / address | — | X | (([939] [321]) ∨ ([940] [322])) ∧ [514] |
3155 EM00200 | Electronic mail | — | X | [1P0..1] |
3155 FX00210 | Fax number | — | X | [1P0..1] |
3155 TE00220 | Telephone | — | X | [1P0..1] |
3155 AJ00230 | further telephone | — | X | [1P0..1] |
3155 AL00240 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00250 | Message recipient | — | X | — |
303900260 | MP-ID | — | X | — |
3055 900270 | GS1 | — | X | — |
3055 29300280 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400290 | Transaction | — | X | — |
740200300 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700310 | Transaction reason | — | X | — |
9013 ZX600320 | Change data of the MaLo | — | X | — |
9013 ZW300330 | Generating market location | — | X | — |
9013 ZW400340 | Consuming market location | — | X | — |
| SG4.STS | — | — | Must | [301] ∧ [557] ∧ [2011] |
9015 E0100350 | Status of the response | — | X | — |
901300360 | Code of the check step | — | X | — |
1131 E_040800370 | EBD no. E_0408 | — | X | — |
901200380 | Time period ID from the change notification of the responsible party | — | X | [914] ∧ [937] ∧ [44] |
| SG5.LOC | — | — | Must | — |
3227 Z1600390 | Market location | — | X | — |
322500400 | ID of the market location | — | X | [950] |
| SG6.RFF | — | — | Must | — |
1153 Z1300410 | Check identifier | — | X | — |
1154 5562200420 | GPKE / Response message / Request for data of the MaLo from LF to NB | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00430 | Transaction reference number | — | X | — |
115400440 | Transaction number | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 Z4700450 | Data available in the system | — | X | [5P0..n] |
1153 Z4800460 | Expected data | — | X | [2P0..n] |
1153 Z5400470 | No data available in the system | — | X | [4P0..n] |
1153 Z5500480 | No data expected | — | X | [2P0..n] |
115600490 | Time period ID | — | X | [914] ∧ [937] [127] ⊻ [128] |
| SG6.DTM | — | — | Must | [131] ⊻ [134] ⊻ [135] |
2005 Z2500500 | Data used from | — | X | — |
238000510 | Date or time or time span, value | — | X | [UB1] |
2379 30300520 | CCYYMMDDHHMMZZZ | — | X | — |
| SG6.DTM | — | — | Must | [472] ⊻ [473] |
2005 Z2600530 | Data used until | — | X | — |
238000540 | Date or time or time span, value | — | X | [UB1] |
2379 30300550 | CCYYMMDDHHMMZZZ | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z8000560 | Expected data of the market location | — | X | [2P0..n] |
1229 Z8100570 | Data of the market location existing in the system | — | X | [3P0..n] |
105000580 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG10.CCI | — | — | Must | — |
7037 ZB300590 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9100600 | MSB | — | X | — |
113100610 | MP-ID | — | X | — |
7110 Z3900620 | Default metering point operator | — | X | — |
7110 Z4000630 | Competitive metering point operator | — | X | — |
7110 Z4100640 | Fallback metering point operator | — | X | — |
7110 Z1900650 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2000660 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0300670 | Voltage level of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0300680 | Extra-high voltage | — | X | — |
7111 E0400690 | High voltage | — | X | — |
7111 E0500700 | Medium voltage | — | X | — |
7111 E0600710 | Low voltage | — | X | — |
| SG10.CAV | — | — | Should | [8] |
7111 E0700720 | EHV/HV transformation | — | X | [116] |
7111 E0800730 | HV/MV transformation | — | X | [115] |
7111 E0900740 | MS/NS transformation | — | X | [114] |
| SG10.CCI | — | — | Must | — |
7037 Z8300750 | Metering classification of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z5200760 | iMS | — | X | — |
7111 Z5300770 | kME / mME | — | X | — |
7111 Z6800780 | no measurement | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z3400790 | Type of the generating market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3300800 | EEG market location without DV obligation | — | X | — |
7111 Z3400810 | KWKG market location without DV obligation | — | X | — |
7111 Z3500820 | other market location | — | X | — |
7111 Z3700830 | EEG market location with DV obligation | — | X | — |
7111 Z4600840 | KWKG market location with DV obligation | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z8900850 | Recipient of the remuneration | — | X | — |
| SG10.CAV | — | — | Must | — |
7110 Z1000860 | Customer | — | X | — |
7110 Z1100870 | Supplier | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2200880 | Statutory category | — | X | — |
7037 Z9000890 | EEG marketing type: default remuneration | — | X | — |
7037 Z9100900 | EEG marketing type: market premium | — | X | — |
7037 Z9200910 | Marketing type without statutory remuneration | — | X | — |
7037 Z9400920 | KWKG remuneration | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2400930 | Status of the remote controllability | — | X | — |
7037 Z9600940 | Market location is not technically remotely controllable | — | X | — |
7037 Z9700950 | Market location is technically remotely controllable | — | X | — |
7037 Z9800960 | Market location can be remotely controlled by the supplier | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZD100970 | Expected consumption type and use of the OBIS code of the market location | — | X | — |
1229 ZD200980 | Consumption type and use of the OBIS indicator of the market location existing in the system | — | X | — |
105000990 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG8.RFF | — | — | Must | — |
1153 Z1001000 | OBIS code | — | X | — |
115401010 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1701020 | Type of electricity consumption | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z6401030 | Power/light | — | X | [1P0..1] |
7111 Z6501040 | Heat/cold | — | X | [1P0..1] |
7111 ZE501050 | E-mobility | — | X | [1P0..1] |
7111 ZA801060 | Street lighting | — | X | [1P0..1] |
7111 ZB301070 | Heat output control | — | X | [1P0..1] |
| SG10.CAV | — | — | Must | — |
7111 Z6201080 | interruptible consumption device | — | X | — |
7111 Z6301090 | non-interruptible consumption device | — | X | — |
| SG10.CAV | — | — | Must | [239] |
7111 Z5601100 | Storage heating | — | X | — |
7111 Z5701110 | Heat pump (unspecified) | — | X | — |
7111 Z6101120 | Direct heating | — | X | — |
7111 ZV501130 | Heat pump (heat and cold) | — | X | — |
7111 ZV601140 | Heat pump (cold) | — | X | — |
7111 ZV701150 | Heat pump (heat) | — | X | — |
| SG10.CAV | — | — | Must | [95] |
7111 ZE601160 | Wallbox | — | X | — |
7111 Z8701170 | E-mobility charging station | — | X | — |
7111 ZE701180 | Charging park | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZD301190 | Expected product data of the market location of the NB | — | X | — |
1229 ZD401200 | Product data of the market location of the NB existing in the system | — | X | — |
105001210 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG8.PIA | — | — | Should | [8] ∧ [648] |
4347 501220 | Product identification | — | X | — |
7140 AUA01230 | Curtailed energy | — | X | — |
7143 Z0801240 | Medium | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z5101250 | Expected customer of the grid operator | — | X | — |
3035 Z5201260 | Customer of the grid operator available in the system | — | X | — |
303601270 | Name | — | X | — |
3045 Z0101280 | Structure of person names | — | X | — |
3045 Z0201290 | Structure of the company name | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z4601300 | Reference to time period ID | — | X | — |
115401310 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG12.NAD | — | — | Must | — |
3035 Z5301320 | Expected correspondence address of the grid operator's customer | — | X | — |
3035 Z5401330 | Correspondence address of the customer of the grid operator available in the system | — | X | — |
303601340 | Name | — | X | — |
3045 Z0101350 | Structure of person names | — | X | — |
3045 Z0201360 | Structure of the company name | — | X | — |
304201370 | Street and house number or PO box | — | X | — |
316401380 | City | — | X | — |
325101390 | Postal code | — | — | M [268] S [166] |
320701400 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z4601410 | Reference to time period ID | — | X | — |
115401420 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG12.NAD | — | — | Must | — |
3035 Z5501430 | Expected connection holder | — | X | — |
3035 Z5601440 | Connection holder available in the system | — | X | — |
303601450 | Name | — | X | — |
3045 Z0101460 | Structure of person names | — | X | — |
3045 Z0201470 | Structure of the company name | — | X | — |
304201480 | Street and house number or PO box | — | X | — |
316401490 | City | — | X | — |
325101500 | Postal code | — | — | M [268] S [166] |
320701510 | Country name, code | — | — | — |
| SG12.RFF | — | — | Must | — |
1153 Z4601520 | Reference to time period ID | — | X | — |
115401530 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG12.NAD | — | — | Must | — |
3035 Z5701540 | Expected property manager | — | X | — |
3035 Z5801550 | Property manager available in the system | — | X | — |
303601560 | Name | — | X | — |
3045 Z0101570 | Structure of person names | — | X | — |
3045 Z0201580 | Structure of the company name | — | X | — |
304201590 | Street and house number or PO box | — | X | — |
316401600 | City | — | X | — |
325101610 | Postal code | — | — | M [268] S [166] |
320701620 | Country name, code | — | — | — |
| SG12.RFF | — | — | Must | — |
1153 Z4601630 | Reference to time period ID | — | X | — |
115401640 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG12.NAD | — | — | Must | — |
3035 Z5901650 | Expected market location address | — | X | — |
3035 Z6001660 | Market location address available in the system | — | X | — |
312401670 | Additional information for identification | — | — | — |
304201680 | Street and house number or PO box | — | — | S [166] M [212] |
316401690 | City | — | X | — |
325101700 | Postal code | — | X | — |
320701710 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z4601720 | Reference to time period ID | — | X | — |
115401730 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| UNT | — | — | Must | — |
007401740 | Number of segments in a message | — | X | — |
006201750 | Message reference number | — | X | — |
Conditions of this table
The free text of the 40 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [8] | If required for data clearing |
| [22] | The time period ID from DE1156 of a matching SG6 RFF+Z47/Z48/Z49 (usage period of the data) must be entered |
| [44] | The time period ID from DE1156 of a matching SG6 RFF+Z49/Z53 (usage period of the data: "valid data", "no data") from the request message from SG6 RFF+TN DE1154 ((reference transaction number (from request message)) must be entered |
| [95] | If in the same SG10 the CCI+Z17 (type of electricity consumption) CAV+ZE5 (e-mobility) is present |
| [114] | If the SG10 CCI+E03 (voltage level of the market location) CAV E06 (low voltage) is present in this SG |
| [115] | If the SG10 CCI+E03 (voltage level of the market location) CAV E05 (medium voltage) is present in this SG |
| [116] | If the SG10 CCI+E03 (voltage level of the market location) CAV E04 (high voltage) is present in this SG |
| [127] | The value resulting from the number of repetitions of the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) must be entered. This means: the first SG6 RFF+Z48/Z55 thus has the „1“, the second the „2“, the third the „3“, etc. |
| [128] | The value resulting from the number of repetitions of the SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) must be entered. This means: the first SG6 RFF+Z47/Z54 thus has the „1“, the second the „2“, the third the „3“, etc. |
| [131] | If this DTM+Z25 (use of the data from) in SG6 RFF (usage period of the data) is marked with the time period ID "1" in DE1156, the date in this DE2380 must be the day immediately following DTM+137 DE2380 (message date) at 0:00, or a day earlier than that at 0:00 German time |
| [134] | If this DTM+Z25 (use of data from) is not in the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) with time period ID "1" in DE1156, the date must correspond to the DTM+Z26 (use of data until) of the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) with the next lower time period ID in DE1156 |
| [135] | If this DTM+Z25 (use of data from) is not in the SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) with time period ID "1" in DE1156, the date must correspond to the DTM+Z26 (use of data until) of the SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) with the next lower time period ID in DE1156 |
| [166] | If present |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [239] | If in the same SG10 the CCI+Z17 (type of electricity consumption) is present in the CAV+Z65 (heat/cooling) |
| [268] | If an "X" is listed for the code in DE3207 in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| [301] | If BGM+E03 (change notification) present |
| [321] | If code EM is present in DE3155 in the same COM |
| [322] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [472] | If a time period ID is named in DE1156 (time period ID) in the same SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) which is lower than in another SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) DE1156 (time period ID) |
| [473] | If a time period ID is named in DE1156 (time period ID) in the same SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) which is lower than in another SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) DE1156 (time period ID) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [557] | Note: If the responsible party has sent more than eight usage periods, eight arbitrary usage periods are answered |
| [648] | Note: If a product is no longer to exist as of the date "change as of", this is expressed by not stating PIA+5 |
| [705] | Note: If the action of a sequence diagram "Response message on change" is carried out |
| [706] | Note: If the action of a sequence diagram "Order placement of a change of master data..." is carried out with the aim of performing a data clearing |
| [914] | Format: Possible value: > 0 |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [2011] | Segment group must be specified exactly once for each time period ID from DE1156 of the SG6 RFF+Z49 / Z53 (usage period of the data: "Valid data" / "No data") from the request message from SG6 RFF+TN DE1154 (reference transaction number (from request message)) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [5P0..n] | [315] If BGM+Z88 (data clearing) present [20 13 ] To be specified at least once , if no SG6 RFF+Z54 (Usage period of the data: no data present in the system) present |
| [2P0..n] | [301] If BGM+E03 (change notification) present [315] If BGM+Z88 (data clearing) present |
| [4P0..n] | [315] If BGM+Z88 (data clearing) present [20 14 ] To be specified at least once , if no SG6 RFF+Z47 (Usage period of the data: data present in the system) present |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [3P0..n] | [315] If BGM+Z88 (data clearing) present |
Example message
Example 1
UNA:+.? '
UNB+UNOC:3+9903729000007:500+9900327000009:500+{{date}}:{{time}}+DAGXJUACYXZVBU'
UNH+DAELIAIYDCHZXR+UTILMD:D:11A:UN:S2.1'
BGM+E03+DA862410171936379903323000007443111'
DTM+137:202506241231?+00:303'
NAD+MS+9903729000007::293'
CTA+IC+:P GETTY'
COM+?+3222271020:TE'
NAD+MR+9900327000009::293'
IDE+24+TRMeldung'
STS+7++ZX6+ZW4'
STS+E01++A02:E_0408::1'
STS+E01++A02:E_0408::2'
LOC+Z16+20072281644'
RFF+Z13:55622'
RFF+TN:MALOMeldung'
RFF+Z48::1'
DTM+Z25:202506232200?+00:303'
DTM+Z26:202507232200?+00:303'
RFF+Z48::2'
DTM+Z25:202507232200?+00:303'
SEQ+Z80+1'
CCI+++ZB3'
CAV+Z91:9904990000008::Z39:Z19'
CCI+++E03'
CAV+E06'
CAV+E09'
CCI+++Z83'
CAV+Z52'
SEQ+Z80+2'
CCI+++ZB3'
CAV+Z91:9904990000008::Z39:Z19'
CCI+++E03'
CAV+E06'
CAV+E09'
CCI+++Z83'
CAV+Z52'
SEQ+ZD1+1'
RFF+Z10:1-1?:1.9.0'
CCI+Z17'
CAV+Z65'
CAV+Z62'
CAV+Z56'
SEQ+ZD1+2'
RFF+Z10:1-1?:1.9.0'
CCI+Z17'
CAV+Z65'
CAV+Z62'
CAV+Z56'
NAD+Z51+++Firma AG:Musterfirma::::Z02'
RFF+Z46:1'
NAD+Z53+++Fank Müller:::::Z01+Wohnstrasse::25:Musterortsteil+Musterstadt++55555+DE'
RFF+Z46:1'
NAD+Z55+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:1'
NAD+Z57+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:1'
NAD+Z59++Die Marktlokation befindet sich i:m Hinterhaus im u:nteren K:eller recht:s++Eichelbergstr.::36:Musterortsteil+Musterstadt++55555+DE'
RFF+Z46:1'
NAD+Z51+++Firma AG:Musterfirma::::Z02'
RFF+Z46:2'
NAD+Z53+++Fank Müller:::::Z01+Wohnstrasse::25:Musterortsteil+Musterstadt++55555+DE'
RFF+Z46:2'
NAD+Z55+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:2'
NAD+Z57+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:2'
NAD+Z59++Die Marktlokation befindet sich i:m Hinterhaus im u:nteren K:eller recht:s++Eichelbergstr.::36:Musterortsteil+Musterstadt++55555+DE'
RFF+Z46:2'
UNT+68+DAELIAIYDCHZXR'
UNZ+1+DAGXJUACYXZVBU'[1 item
{6 fields
"data": {3 fields
"stammdaten": {3 fields
"VERWENDUNGSZEITRAUM": [2 items
{6 fields
{5 fields
"MARKTLOKATION": [2 items
{15 fields
"marktlokationsTyp": [1 item
{1 field
"gueltigkeitszeitraum": {3 fields
"lokationsadresse": {7 fields
"zusatzInformation": {5 fields
"marktrollen": [1 item
{8 fields
"zaehlwerke": [1 item
{4 fields
"verbrauchsart": [1 item
"eigentuemer": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
"hausverwalter": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
{15 fields
"marktlokationsTyp": [1 item
{1 field
"gueltigkeitszeitraum": {2 fields
"lokationsadresse": {7 fields
"zusatzInformation": {5 fields
"marktrollen": [1 item
{8 fields
"zaehlwerke": [1 item
{4 fields
"verbrauchsart": [1 item
"eigentuemer": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
"hausverwalter": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
"NETZNUTZUNGSVERTRAG": [2 items
{10 fields
"gueltigkeitszeitraum": {3 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"korrespondenzpartner": {5 fields
"partneradresse": {6 fields
{10 fields
"gueltigkeitszeitraum": {2 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"korrespondenzpartner": {5 fields
"partneradresse": {6 fields
"transaktionsdaten": {14 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"rufnummern": [1 item
{2 fields
"empfaenger": {5 fields
"antwortStatusZeitraum": [2 items
{3 fields
{3 fields
Download: EDIFACT file · BO4E JSON
Example 2
UNA:+.? '
UNB+UNOC:3+9903729000007:500+9900327000009:500+{{date}}:{{time}}+DAWHROWRJIYSPK'
UNH+DAUJOYYSVERCBU+UTILMD:D:11A:UN:S2.1'
BGM+E03+DA172410171938079903323000007885034'
DTM+137:202506241231?+00:303'
NAD+MS+9903729000007::293'
CTA+IC+:P GETTY'
COM+?+3222271020:TE'
NAD+MR+9900327000009::293'
IDE+24+TRMeldung'
STS+7++ZX6+ZW4'
STS+E01++A02:E_0408::1'
STS+E01++A02:E_0408::2'
LOC+Z16+20072281644'
RFF+Z13:55622'
RFF+TN:MALOMeldung'
RFF+Z48::1'
DTM+Z25:202506232200?+00:303'
DTM+Z26:202507232200?+00:303'
RFF+Z48::2'
DTM+Z25:202507232200?+00:303'
SEQ+Z80+1'
CCI+++ZB3'
CAV+Z91:9904990000008::Z39:Z19'
CCI+++E03'
CAV+E06'
CAV+E09'
CCI+++Z83'
CAV+Z52'
SEQ+Z80+2'
CCI+++ZB3'
CAV+Z91:9904990000008::Z39:Z19'
CCI+++E03'
CAV+E06'
CAV+E09'
CCI+++Z83'
CAV+Z52'
SEQ+ZD1+1'
RFF+Z10:1-1?:1.9.0'
CCI+Z17'
CAV+ZE5'
CAV+Z62'
CAV+ZE6'
SEQ+ZD1+2'
RFF+Z10:1-1?:1.9.0'
CCI+Z17'
CAV+ZE5'
CAV+Z62'
CAV+ZE6'
NAD+Z51+++Firma AG:Musterfirma::::Z02'
RFF+Z46:1'
NAD+Z53+++Fank Müller:::::Z01+Wohnstrasse::25:Musterortsteil+Musterstadt++55555+DE'
RFF+Z46:1'
NAD+Z55+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:1'
NAD+Z57+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:1'
NAD+Z59++Die Marktlokation befindet sich i:m Hinterhaus im u:nteren K:eller recht:s++Eichelbergstr.::36:Musterortsteil+Musterstadt++55555+DE'
RFF+Z46:1'
NAD+Z51+++Firma AG:Musterfirma::::Z02'
RFF+Z46:2'
NAD+Z53+++Fank Müller:::::Z01+Wohnstrasse::25:Musterortsteil+Musterstadt++55555+DE'
RFF+Z46:2'
NAD+Z55+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:2'
NAD+Z57+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:2'
NAD+Z59++Die Marktlokation befindet sich i:m Hinterhaus im u:nteren K:eller recht:s++Eichelbergstr.::36:Musterortsteil+Musterstadt++55555+DE'
RFF+Z46:2'
UNT+68+DAUJOYYSVERCBU'
UNZ+1+DAWHROWRJIYSPK'[1 item
{6 fields
"data": {3 fields
"stammdaten": {3 fields
"VERWENDUNGSZEITRAUM": [2 items
{6 fields
{5 fields
"MARKTLOKATION": [2 items
{15 fields
"marktlokationsTyp": [1 item
{1 field
"gueltigkeitszeitraum": {3 fields
"lokationsadresse": {7 fields
"zusatzInformation": {5 fields
"marktrollen": [1 item
{8 fields
"zaehlwerke": [1 item
{4 fields
"verbrauchsart": [1 item
"eigentuemer": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
"hausverwalter": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
{15 fields
"marktlokationsTyp": [1 item
{1 field
"gueltigkeitszeitraum": {2 fields
"lokationsadresse": {7 fields
"zusatzInformation": {5 fields
"marktrollen": [1 item
{8 fields
"zaehlwerke": [1 item
{4 fields
"verbrauchsart": [1 item
"eigentuemer": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
"hausverwalter": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
"NETZNUTZUNGSVERTRAG": [2 items
{10 fields
"gueltigkeitszeitraum": {3 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"korrespondenzpartner": {5 fields
"partneradresse": {6 fields
{10 fields
"gueltigkeitszeitraum": {2 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"korrespondenzpartner": {5 fields
"partneradresse": {6 fields
"transaktionsdaten": {14 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"rufnummern": [1 item
{2 fields
"empfaenger": {5 fields
"antwortStatusZeitraum": [2 items
{3 fields
{3 fields
Download: EDIFACT file · BO4E JSON
Example 3
UNA:+.? '
UNB+UNOC:3+9903729000007:500+9900327000009:500+{{date}}:{{time}}+DAWFVNIDWVJJHS'
UNH+DAYPICEOVYBJYW+UTILMD:D:11A:UN:S2.1'
BGM+E03+DA522410171925589903323000007700494'
DTM+137:202506241231?+00:303'
NAD+MS+9903729000007::293'
CTA+IC+:P GETTY'
COM+?+3222271020:TE'
NAD+MR+9900327000009::293'
IDE+24+TRMeldung'
STS+7++ZX6+ZW3'
STS+E01++A02:E_0408::1'
STS+E01++A02:E_0408::2'
LOC+Z16+20072281644'
RFF+Z13:55622'
RFF+TN:MALOMeldung'
RFF+Z48::1'
DTM+Z25:202506232200?+00:303'
DTM+Z26:202507232200?+00:303'
RFF+Z48::2'
DTM+Z25:202507232200?+00:303'
SEQ+Z80+1'
CCI+++ZB3'
CAV+Z91:9904990000008::Z39:Z19'
CCI+++E03'
CAV+E06'
CAV+E09'
CCI+++Z83'
CAV+Z52'
CCI+++Z34'
CAV+Z33'
CCI+++Z89'
CAV+:::Z10'
CCI+Z22++Z90'
CCI+Z24++Z96'
SEQ+Z80+2'
CCI+++ZB3'
CAV+Z91:9904990000008::Z39:Z19'
CCI+++E03'
CAV+E06'
CAV+E09'
CCI+++Z83'
CAV+Z52'
CCI+++Z34'
CAV+Z33'
CCI+++Z89'
CAV+:::Z10'
CCI+Z22++Z90'
CCI+Z24++Z96'
SEQ+ZD3+1'
PIA+5+AUA:Z08'
SEQ+ZD3+2'
PIA+5+AUA:Z08'
UNT+52+DAYPICEOVYBJYW'
UNZ+1+DAWFVNIDWVJJHS'[1 item
{6 fields
"data": {3 fields
"stammdaten": {2 fields
"VERWENDUNGSZEITRAUM": [2 items
{6 fields
{5 fields
"MARKTLOKATION": [2 items
{16 fields
"marktlokationsTyp": [1 item
{1 field
"gueltigkeitszeitraum": {3 fields
"marktrollen": [1 item
{8 fields
"energieherkunft": [1 item
{1 field
{16 fields
"marktlokationsTyp": [1 item
{1 field
"gueltigkeitszeitraum": {2 fields
"marktrollen": [1 item
{8 fields
"energieherkunft": [1 item
{1 field
"transaktionsdaten": {14 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"rufnummern": [1 item
{2 fields
"empfaenger": {5 fields
"antwortStatusZeitraum": [2 items
{3 fields
{3 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ÜNB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Order placement for a master data change to the NB (responsible) | GPKE part 4 | Electricity | Step 1 |
| LF | LF | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 2 |
| NB | NB | Order placement for a master data change to the NB (responsible) | GPKE part 4 | Electricity | Step 1 |
| NB | NB | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 2 |
| MSB | MSB | Order placement for a master data change to the NB (responsible) | GPKE part 4 | Electricity | Step 1 |
| MSB | MSB | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 2 |
| ÜNB | ÜNB | Order placement for a master data change to the NB (responsible) | GPKE part 4 | Electricity | Step 1 |
| ÜNB | ÜNB | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response message/request data of the MaLo |
| AHB | UTILMD AHB electricity |
| Response to check identifier | 55616 |
| Decision tree | E_0408 |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 4 | Master data change initiated by the NB (responsible) | LF → NB | Response message on change |
| GPKE part 4 | Order placement for master data change to NB (responsible) | LF → NB | Order placement of a change of master data from the LF to NB |
One entry from format version 202610
The check identifiers table of format version 202604 does not carry this entry: decision tree. It comes from version 202610. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202604.
Transaction and responses
Role of this check identifier: response message. Basis: the title or the action of the Prüfi table begins with “response message”. A response message carries no status field and is not a response in the sense of a decision tree.
Responses: No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDS has the same row structure in this version.
Editorial — not derived from a source
The period ID of this response comes from the request. Condition [44] requires in STS DE9012: »Es ist die Zeitraum-ID vom DE1156 aus einem passenden SG6 RFF+Z49/Z53 … einzutragen« (the period ID from DE1156 of a matching SG6 RFF+Z49/Z53 of the request). In the JSON it is in transaktionsdaten.antwortStatusZeitraum → zeitraumId (SG4.IDE+24.STS+E01). Its value is the zeitraumId of the request's usage period that the response refers to: stammdaten.VERWENDUNGSZEITRAUM → zeitraumId (SG4.IDE+24.SG6.RFF+[Z49|Z53]).
Source: UTILMD AHB electricity (Knowledge Collection ahb/202604/UTILMDS and ahb/202610/UTILMDS), condition [44] at SG4 STS DE9012; segment mapping of the zeitraumId fields in the check identifier specifications · As of: 2026-09-23 · Applies to format version: 202604, 202610 · To be reviewed by: 2027-04-01
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 225 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains 3 transactions for this check identifier under the message type utilmd. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.