Check identifier 55629 — Change to data of TR
Check identifier 55629 · EDIFACT message type UTILMD · format version 202610
Data structure
| Structure (BO4E) | Description | Format | 55629 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| TECHNISCHE_RESSOURCE [ ] * | — | object[] | Must | — |
| art 00010 | Technical resource type | Enum TechnischeRessourceArt | Must | — |
STROMERZEUGUNG | — | — | Must | — |
STROMVERBRAUCH | — | — | Must | — |
SPEICHER | — | — | Must | — |
| artEMobilitaet 00020 | ArtEmobilitaet | Enum ArtEmobilitaet | Must | [446] |
WB | — | — | Must | — |
LS | — | — | Must | — |
LP | — | — | Must | — |
| datenqualitaet 00030 | Data quality | Enum Datenqualitaet | X | — |
ERWARTETE_DATEN | — | — | X | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | X | — |
INFORMATIVE_DATEN | — | — | X | — |
GUELTIGE_DATEN | — | — | X | — |
KEINE_DATEN | — | — | X | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | X | — |
KEINE_DATEN_ERWARTET | — | — | X | — |
DIFFERENZ_DATEN | — | — | X | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | X | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | X | — |
| enwg 00040 | enwg | boolean | Must | [446] |
| erzeugungsart 00050 | Type of energy generation. Details generation type Example: CAV+ZF5' Generation type: ZF5: solar ZF6: wind ZG0: gas ZG1: water ZG5: other generation type | Enum Erzeugungsart | Must | [446] |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| referenzNetzlokation 00060 | referenzNetzlokation | string | X | — |
| referenzSteuerbareRessource 00070 | referenzSteuerbareRessource | string | X | — |
| referenzTranche 00080 | referenzTranche | string | X | — |
| ressourcenId * 00090 | ressourcenId | string | X | — |
| speicherart 00100 | Type of storage. Details storage type Example: CAV+ZF7' Storage type: ZF7: hydrogen storage ZF8: pumped storage ZF9: battery storage ZG6: other storage type | Enum Speicherart | Must | [446] |
WASSERSTOFFSPEICHER | — | — | Must | — |
PUMPSPEICHER | — | — | Must | — |
BATTERIESPEICHER | — | — | Must | — |
SONSTIGE_SPEICHERART | — | — | Must | — |
| speicherkapazitaet 00110 | Storage capacity Example: QTY+Z42:100:KWH' | number (float) | X | — |
| verbrauchsart 00120 | Consumption type of the technical resource Example: CAV+Z64' Z64: Power/light Z65: Heat ZE5: E-mobility ZA8: Street lighting | array | Must | [446] |
| waermenutzung 00130 | Heat usage Example: CAV+Z56' Z56: Storage heating Z57: Heat pump Z61: Direct heating | Enum Waermenutzung | Must | [446] |
SPEICHERHEIZUNG | — | — | Must | — |
WAERMEPUMPE | — | — | Must | — |
DIREKTHEIZUNG | — | — | Must | — |
WAERMEPUMPE_WAERME_KAELTE | — | — | Must | — |
WAERMEPUMPE_KAELTE | — | — | Must | — |
WAERMEPUMPE_WAERME | — | — | Must | — |
| gueltigkeitszeitraum | — | object | May | — |
| zeitraumId 00140 | zeitraumId | integer | X | — |
| nennleistung | — | object | May | — |
| abgabe 00150 | Submission of the rated capacity | number (float) | X | — |
| aufnahme 00160 | Recording of the rated power | number (float) | X | — |
| VERWENDUNGSZEITRAUM [ ] * | — | object[] | Must | — |
| datenqualitaet * 00170 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| verwendungAb * 00180 | verwendungAb | string (date-time) | X | — |
| verwendungBis 00190 | verwendungBis | string (date-time) | X | — |
| zeitraumId * 00200 | zeitraumId | integer | Must | — |
| transaktionsdaten * | — | object | Must | — |
| dokumentennummer * 00210 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| kategorie * 00220 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 00230 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00240 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00250 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 00260 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vorgangsnummer * 00270 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00280 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00290 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00300 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00310 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55629 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0300070 | Change notifications | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/ message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMM ZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document/message issuer or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00160 | Message recipient | — | X | — |
303900170 | MP-ID | — | X | — |
3055 900180 | GS1 | — | X | — |
3055 29300190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400200 | Transaction | — | X | — |
740200210 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700220 | Transaction reason | — | X | — |
9013 ZY000230 | Change data of the TR | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z2000240 | Technical resource | — | X | — |
322500250 | ID of the technical resource | — | X | [922] |
| SG6.RFF | — | — | Must | — |
1153 Z1300260 | Check identifier | — | X | — |
1154 5562900270 | GPKE / Change data of the TR from NB to MSB | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 Z4900280 | Valid data | — | X | [1P0..n] |
1153 Z5300290 | No data | — | X | [1P0..n] |
115600300 | Time period ID | — | X | [914] ∧ [937] [126] |
| SG6.DTM | — | — | Must | [131] ⊻ [401] |
2005 Z2500310 | Data used from | — | X | — |
238000320 | Date or time or time span, value | — | X | [UB1] |
2379 30300330 | CCYYMMDDHHMM ZZZ | — | X | — |
| SG6.DTM | — | — | Must | [471] |
2005 Z2600340 | Data used until | — | X | — |
238000350 | Date or time or time span, value | — | X | [UB1] |
2379 30300360 | CCYYMMDDHHMM ZZZ | — | X | — |
| SG10.CAV | — | — | Must | [446] |
| SG8.SEQ | — | — | Must | — |
1229 Z5200370 | Data of the technical resource | — | X | — |
105000380 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG8.RFF | — | — | Should | [166] ∧ [699] |
1153 Z3800390 | Controllable resource | — | X | — |
115400400 | ID of the controllable resource | — | X | [961] |
| SG8.RFF | — | — | Should | [166] ∧ [700] |
1153 Z3200410 | Grid location | — | X | — |
115400420 | ID of the grid location | — | X | [960] |
| SG8.RFF | — | — | Should | [166] ∧ [447] ∧ [701] |
1153 Z2000430 | Tranche | — | X | — |
115400440 | ID of the tranche | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 Z4300450 | Rated power (input) | — | X | — |
606000460 | Quantity | — | X | — |
6411 KWT00470 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4400480 | Rated power (output) | — | X | — |
606000490 | Quantity | — | X | — |
6411 KWT00500 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4200510 | Storage capacity | — | X | — |
606000520 | Quantity | — | X | — |
6411 KWH00530 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1700540 | Type of electricity consumption | — | X | — |
7059 Z5000550 | Type of electricity generation | — | X | — |
7059 Z5600560 | Storage | — | X | — |
| SG10.CAV | — | — | Must | [446] |
7111 Z6400570 | Power/light | — | X | [1P0..1] |
7111 Z6500580 | Heat/cold | — | X | [1P0..1] |
7111 ZE500590 | E-mobility | — | X | [1P0..1] |
7111 ZA800600 | Street lighting | — | X | [1P0..1] |
| SG10.CAV | — | — | Must | [239] |
7111 Z5600610 | Storage heating | — | X | — |
7111 Z5700620 | Heat pump (unspecified) | — | X | — |
7111 Z6100630 | Direct heating | — | X | — |
7111 ZV500640 | Heat pump (heat and cold) | — | X | — |
7111 ZV600650 | Heat pump (cold) | — | X | — |
7111 ZV700660 | Heat pump (heat) | — | X | — |
| SG10.CAV | — | — | Must | [95] |
7111 ZE600670 | Wallbox | — | X | — |
7111 Z8700680 | E- mobility charging station | — | X | — |
7111 ZE700690 | Charging park | — | X | — |
| SG10.CAV | — | — | Must | [447] |
7111 ZF500700 | Solar | — | X | — |
7111 ZF600710 | Wind | — | X | — |
7111 ZG000720 | Gas | — | X | — |
7111 ZG100730 | Water | — | X | — |
7111 ZG500740 | Other generation type | — | X | — |
| SG10.CAV | — | — | Must | [448] |
7111 ZF700750 | Hydrogen storage | — | X | — |
7111 ZF800760 | Pumped storage | — | X | — |
7111 ZF900770 | Battery storage | — | X | — |
7111 ZG600780 | Other storage type | — | X | — |
| SG10.CAV | — | — | Must | [446] ⊻ [448] |
7111 ZG800790 | Technical resource is covered by § 14a EnWG | — | X | — |
7111 ZG900800 | Technical resource is not covered by § 14a EnWG | — | X | — |
| UNT | — | — | Must | — |
007400810 | Number of segments in a message | — | X | — |
006200820 | Message reference number | — | X | — |
Conditions of this table
The free text of the 25 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [22] | The time period ID from DE1156 of a matching SG6 RFF+Z47/Z48/Z49 (usage period of the data) must be entered |
| [95] | If in the same SG10 the CCI+Z17 (type of electricity consumption ) CAV+ZE5 (e-mobility) is present |
| [126] | The value resulting from the number of repetitions of the SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) must be entered. This means: the first SG6 RFF+Z49/Z53 thus has the „1“, the second the „2“, the third the „3“, etc. |
| [131] | If this DTM+Z25 (use of the data from) in SG6 RFF (usage peri od of the data) is marked with the time period ID "1" in DE1156, the date in this DE2380 must be the day immediately following DTM+137 DE2380 (message dat e) at 0:00, or a day earlier than that at 0:00 German time |
| [166] | If present |
| [239] | If in the same SG10 the CCI+Z17 (type of electricity consumption ) is present in the CAV+Z65 (heat/cooling) |
| [401] | If this DTM+Z25 (use of data from) is not in the SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) with time period ID "1" in DE1156, the date must correspond to the DTM+Z26 (use of data until) of the SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) with the next lower time period ID in DE1156 |
| [446] | If in the same SG8 the CCI+Z17 (type of electricity consumption ) is present |
| [447] | If in the same SG8 the CCI+Z50 (type of electricity generation ) is present |
| [448] | If in the same SG8 the CCI+Z56 (storage) is present |
| [471] | If a time period ID is named in DE1156 (time period ID) in the same SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) which is lower than in another SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) DE1156 (time period ID) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [699] | Note: The ID of the controllable resource via which the technical resource is controlled must be specified |
| [700] | Note: The ID of the grid location via which the technical resource is controlled must be specified |
| [701] | Note: The Malo ID of the tranche to which the technical resource is assigned must be specified |
| [914] | Format: Possible value: > 0 |
| [922] | Format: TR-ID |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [950] | Format: market location ID |
| [960] | Format: Grid location ID |
| [961] | Format: SR-ID |
| [1P0..n] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
Example 1
UNA:+.? '
UNB+UNOC:3+9900327000009:500+9910812000000:500+{{date}}:{{time}}+DAAZPSHRYDEGQZ'
UNH+DAWTXTAVQRCZDO+UTILMD:D:11A:UN:S2.2'
BGM+E03+DA142411081003059903323000007901049'
DTM+137:202610021100?+00:303'
NAD+MS+9900327000009::293'
NAD+MR+9910812000000::293'
IDE+24+24062416225400000000000102159662011'
STS+7++ZY0'
LOC+Z20+D417MLM8164'
RFF+Z13:55629'
RFF+Z49::1'
DTM+Z25:202506232200?+00:303'
DTM+Z26:202507232200?+00:303'
RFF+Z49::2'
DTM+Z25:202507232200?+00:303'
SEQ+Z52+1'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z43:100:KWT'
CCI+Z17'
CAV+Z65'
CAV+ZV5'
CAV+ZG8'
SEQ+Z52+2'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z43:100:KWT'
CCI+Z17'
CAV+Z65'
CAV+ZV5'
CAV+ZG8'
UNT+31+DAWTXTAVQRCZDO'
UNZ+1+DAAZPSHRYDEGQZ'[1 item
{6 fields
"data": {3 fields
"stammdaten": {3 fields
"VERWENDUNGSZEITRAUM": [2 items
{6 fields
{5 fields
"TECHNISCHE_RESSOURCE": [2 items
{13 fields
"gueltigkeitszeitraum": {3 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
{13 fields
"gueltigkeitszeitraum": {2 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
"STEUERBARE_RESSOURCE": [1 item
{4 fields
"transaktionsdaten": {11 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 2
UNA:+.? '
UNB+UNOC:3+9900327000009:500+9910812000000:500+{{date}}:{{time}}+DAYEVJDKDEJBXP'
UNH+DAGYEYPLUEARCZ+UTILMD:D:11A:UN:S2.2'
BGM+E03+DA062411081016419903323000007881060'
DTM+137:202610021100?+00:303'
NAD+MS+9900327000009::293'
NAD+MR+9910812000000::293'
IDE+24+24062416225400000000000102159662011'
STS+7++ZY0'
LOC+Z20+D417MLM8164'
RFF+Z13:55629'
RFF+Z49::1'
DTM+Z25:202506232200?+00:303'
DTM+Z26:202507232200?+00:303'
RFF+Z49::2'
DTM+Z25:202507232200?+00:303'
SEQ+Z52+1'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z44:100:KWT'
CCI+Z50'
CAV+ZF5'
SEQ+Z52+2'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z44:100:KWT'
CCI+Z50'
CAV+ZF5'
UNT+27+DAGYEYPLUEARCZ'
UNZ+1+DAYEVJDKDEJBXP'[1 item
{6 fields
"data": {3 fields
"stammdaten": {3 fields
"VERWENDUNGSZEITRAUM": [2 items
{6 fields
{5 fields
"TECHNISCHE_RESSOURCE": [2 items
{11 fields
"gueltigkeitszeitraum": {3 fields
"nennleistung": {1 field
{11 fields
"gueltigkeitszeitraum": {2 fields
"nennleistung": {1 field
"STEUERBARE_RESSOURCE": [1 item
{4 fields
"transaktionsdaten": {11 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 3
UNA:+.? '
UNB+UNOC:3+9900327000009:500+9910812000000:500+{{date}}:{{time}}+DAOHLJRJDBVPON'
UNH+DAQKCDFHXBZNGC+UTILMD:D:11A:UN:S2.2'
BGM+E03+DA972411081015249903323000007896320'
DTM+137:202610021100?+00:303'
NAD+MS+9900327000009::293'
NAD+MR+9910812000000::293'
IDE+24+24062416225400000000000102159662011'
STS+7++ZY0'
LOC+Z20+D417MLM8164'
RFF+Z13:55629'
RFF+Z49::1'
DTM+Z25:202506232200?+00:303'
DTM+Z26:202507232200?+00:303'
RFF+Z49::2'
DTM+Z25:202507232200?+00:303'
SEQ+Z52+1'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z43:100:KWT'
QTY+Z44:100:KWT'
QTY+Z42:100:KWH'
CCI+Z56'
CAV+ZF7'
CAV+ZG9'
SEQ+Z52+2'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z43:100:KWT'
QTY+Z44:100:KWT'
QTY+Z42:100:KWH'
CCI+Z56'
CAV+ZF7'
CAV+ZG9'
UNT+33+DAQKCDFHXBZNGC'
UNZ+1+DAOHLJRJDBVPON'[1 item
{6 fields
"data": {3 fields
"stammdaten": {3 fields
"VERWENDUNGSZEITRAUM": [2 items
{6 fields
{5 fields
"TECHNISCHE_RESSOURCE": [2 items
{13 fields
"gueltigkeitszeitraum": {3 fields
"nennleistung": {2 fields
{13 fields
"gueltigkeitszeitraum": {2 fields
"nennleistung": {2 fields
"STEUERBARE_RESSOURCE": [1 item
{4 fields
"transaktionsdaten": {11 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 4
UNA:+.? '
UNB+UNOC:3+9900327000009:500+9910812000000:500+{{date}}:{{time}}+DAKGWCRNHQDZCL'
UNH+DAPTCWIDYJQBPF+UTILMD:D:11A:UN:S2.2'
BGM+E03+DA032411081001279903323000007756470'
DTM+137:202610021100?+00:303'
NAD+MS+9900327000009::293'
NAD+MR+9910812000000::293'
IDE+24+24062416225400000000000102159662011'
STS+7++ZY0'
LOC+Z20+D417MLM8164'
RFF+Z13:55629'
RFF+Z49::1'
DTM+Z25:202506232200?+00:303'
DTM+Z26:202507232200?+00:303'
RFF+Z49::2'
DTM+Z25:202507232200?+00:303'
SEQ+Z52+1'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z43:100:KWT'
CCI+Z17'
CAV+ZE5'
CAV+Z87'
CAV+ZG8'
SEQ+Z52+2'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z43:100:KWT'
CCI+Z17'
CAV+ZE5'
CAV+Z87'
CAV+ZG8'
UNT+31+DAPTCWIDYJQBPF'
UNZ+1+DAKGWCRNHQDZCL'[1 item
{6 fields
"data": {3 fields
"stammdaten": {3 fields
"VERWENDUNGSZEITRAUM": [2 items
{6 fields
{5 fields
"TECHNISCHE_RESSOURCE": [2 items
{14 fields
"gueltigkeitszeitraum": {3 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
{14 fields
"gueltigkeitszeitraum": {2 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
"STEUERBARE_RESSOURCE": [1 item
{4 fields
"transaktionsdaten": {11 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ÜNB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 4 |
| NB | NB | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 4 |
| MSB | MSB | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 4 |
| ÜNB | ÜNB | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 4 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Change data of the TR |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 4 | Master data change initiated by the NB (responsible) | NB → MSB | Change from the NB to MSB |
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.
Responses: No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 110 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains 4 transactions for this check identifier under the message type utilmd. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.