Check identifier 55223 — DZÜ list
Check identifier 55223 · EDIFACT message type UTILMD · format version 202604
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55223 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.100060 | Version number of the underlying BDEW message description | — | X | — |
006800070 | General assignment reference | — | — | S [1] |
007000080 | Transmission sequence number | — | — | M [252] |
0073 C00090 | Start | — | — | M [2] |
0073 F00100 | End | — | — | S [3] |
| BGM | — | — | Must | — |
1001 Z3700110 | DZÜ list | — | X | — |
100400120 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700130 | Document-/message date/time | — | X | — |
238000140 | Date or time or time span, value | — | X | [931] [494] |
2379 30300150 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | — |
2005 15700160 | Validity, start date | — | X | — |
238000170 | Date or time or time span, value | — | X | — |
2379 61000180 | CCYYMM | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00190 | Document-/message sender or sender | — | X | — |
303900200 | MP-ID | — | X | — |
3055 900210 | GS1 | — | X | — |
3055 29300220 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00230 | Information contact | — | X | — |
341200240 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800250 | Number / address | — | X | (([939] [321]) ∨ ([940] [322])) ∧ [514] |
3155 EM00260 | Electronic mail | — | X | [1P0..1] |
3155 FX00270 | Fax number | — | X | [1P0..1] |
3155 TE00280 | Telephone | — | X | [1P0..1] |
3155 AJ00290 | further telephone | — | X | [1P0..1] |
3155 AL00300 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00310 | Message recipient | — | X | — |
303900320 | MP-ID | — | X | [280] |
3055 900330 | GS1 | — | X | — |
3055 29300340 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | [564] |
7495 Z0100350 | List | — | X | — |
740200360 | List number | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1500370 | MaBiS metering point | — | X | — |
322500380 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300390 | Check identifier | — | X | — |
1154 5522300400 | MaBiS / DZÜ list | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2200410 | Data of the aggregated time series | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 AUU00420 | Reference to a time series | — | X | — |
115400430 | Version of the time series | — | X | — |
| SG4.IDE | — | — | Must | [565] |
7495 2400440 | Transaction | — | X | — |
740200450 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700460 | Transaction reason | — | X | — |
9013 ZP300470 | Master data | — | X | — |
9013 ZP400480 | Values | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1600490 | Market location | — | X | — |
322500500 | ID of the market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2100510 | Tranche | — | X | — |
322500520 | ID of the tranche | — | X | [950] |
| SG8.SEQ | — | — | Must | — |
1229 Z4700530 | Data status of the ÜNB | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 3100540 | Estimated annual quantity total | — | X | — |
606000550 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH00560 | Kilowatt hour | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z3600570 | Energy quantity: DZÜ share | — | X | — |
606000580 | Quantity specification | — | X | — |
6411 KWH00590 | Kilowatt hour | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15800600 | Start of balancing | — | X | — |
238000610 | Date or time or time span, value | — | X | [UB1] |
2379 30300620 | CCYYMMDDHHMMZZZ | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15900630 | End of balancing | — | X | — |
238000640 | Date or time or time span, value | — | X | [UB1] |
2379 30300650 | CCYYMMDDHHMMZZZ | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4500660 | Energy quantity to be balanced | — | X | — |
606000670 | Quantity specification | — | X | — |
6411 KWH00680 | Kilowatt hour | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15800690 | Start of balancing | — | X | — |
238000700 | Date or time or time span, value | — | X | [UB1] |
2379 30300710 | CCYYMMDDHHMMZZZ | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15900720 | End of balancing | — | X | — |
238000730 | Date or time or time span, value | — | X | [UB1] |
2379 30300740 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1900750 | Balancing group | — | X | — |
703700760 | Balancing group | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2000770 | Balancing area | — | X | — |
703700780 | Balancing area | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1500790 | Structure | — | X | — |
7037 Z2100800 | Aggregated time series type | — | X | — |
| SG10.CAV | — | — | Must | — |
711100810 | Code of the time series type | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0200820 | Standard load profile | — | X | — |
7059 Z0400830 | Standard feed-in profile | — | X | — |
| SG10.CAV | — | — | Must | — |
711100840 | Code of the standardized profile | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 600850 | Responsible party | — | X | — |
7037 ZA800860 | NB | — | X | — |
7037 ZA900870 | ÜNB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZG300880 | Location in regular operation | — | X | — |
7111 ZG400890 | Location outside regular operation (decommissioning) | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z4800900 | Billed data of the balancing group aggregated time series of ÜNB | — | X | — |
| SG8.RFF | — | — | Must | [660] |
1153 AVE00910 | Reporting point | — | X | — |
115400920 | ID of the aggregated time series | — | X | [951] |
| SG8.RFF | — | — | Must | — |
1153 AUU00930 | Reference to a time series | — | X | — |
115400940 | Version of the time series | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 3100950 | Estimated annual quantity total | — | X | — |
606000960 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH00970 | Kilowatt hour | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z0700980 | Actually balanced energy quantity | — | X | — |
606000990 | Quantity specification | — | X | — |
6411 KWH01000 | Kilowatt hour | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15801010 | Start of balancing | — | X | — |
238001020 | Date or time or time span, value | — | X | [UB1] ∧ [454] |
2379 30301030 | CCYYMMDDHHMMZZZ | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15901040 | End of balancing | — | X | — |
238001050 | Date or time or time span, value | — | X | [UB1] ∧ [455] |
2379 30301060 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1901070 | Balancing group | — | X | — |
703701080 | Balancing group | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2001090 | Balancing area | — | X | — |
703701100 | Balancing area | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1501110 | Structure | — | X | — |
7037 Z2101120 | Aggregated time series type | — | X | — |
| SG10.CAV | — | — | Must | — |
711101130 | Code of the time series type | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0201140 | Standard load profile | — | X | — |
7059 Z0401150 | Standard feed-in profile | — | X | — |
| SG10.CAV | — | — | Must | — |
711101160 | Code of the standardized profile | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z4901170 | Billed data of the balancing area aggregate time series of ÜNB | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 AVE01180 | Reporting point | — | X | — |
115401190 | ID of the aggregated time series | — | X | [951] |
| SG8.RFF | — | — | Must | — |
1153 AUU01200 | Reference to a time series | — | X | — |
115401210 | Version of the time series | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 3101220 | Estimated annual quantity total | — | X | — |
606001230 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH01240 | Kilowatt hour | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z0701250 | Actually balanced energy quantity | — | X | — |
606001260 | Quantity specification | — | X | — |
6411 KWH01270 | Kilowatt hour | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15801280 | Start of balancing | — | X | — |
238001290 | Date or time or time span, value | — | X | [UB1] ∧ [454] |
2379 30301300 | CCYYMMDDHHMMZZZ | — | X | — |
| SG9.DTM | — | — | Must | — |
2005 15901310 | End of balancing | — | X | — |
238001320 | Date or time or time span, value | — | X | [UB1] ∧ [455] |
2379 30301330 | CCYYMMDDHHMMZZZ | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2001340 | Balancing area | — | X | — |
703701350 | Balancing area | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1501360 | Structure | — | X | — |
7037 Z2101370 | Aggregated time series type | — | X | — |
| SG10.CAV | — | — | Must | — |
711101380 | Code of the time series type | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0201390 | Standard load profile | — | X | — |
7059 Z0401400 | Standard feed-in profile | — | X | — |
| SG10.CAV | — | — | Must | — |
711101410 | Code of the standardized profile | — | X | — |
| UNT | — | — | Must | — |
007401420 | Number of segments in a message | — | X | — |
006201430 | Message reference number | — | X | — |
Conditions of this table
The free text of the 23 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [1] | If a split is present |
| [2] | If UNH DE0070 (transmission sequence number) with 1 is present |
| [3] | In the case of splitting, in the message with the highest transmission sequence number |
| [252] | If DE0068 is present |
| [280] | Only MP-ID from the electricity division |
| [321] | If code EM is present in DE3155 in the same COM |
| [322] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [454] | The balancing start date must be earlier than the balancing end date in the SG8 “Data status of the ÜNB”, SG 9 energy quantity DZÜ share |
| [455] | The balancing end date must be later than the balancing start date in the SG8 “Data status of the ÜNB” , SG 9 energy quantity DZÜ share |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [564] | Note: The IDE+Z01 (list) defines the business transaction. All listed IDE+24 are part of the business transaction |
| [565] | Note: The IDE+24 describes a component of a list if a IDE+Z01 is present. It does not describe the business transaction |
| [660] | Note: The ID of the BK aggregated time series, aggregation level BG, must be specified |
| [902] | Format: Possible value: ≥ 0 |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB and ÜNB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | NB | Exchange of the delta time series carry-over list from ÜNB to NB | MaBiS | Electricity | Step 1 |
| ÜNB | ÜNB | Exchange of the delta time series carry-over list from ÜNB to NB | MaBiS | Electricity | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | DZÜ list |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Exchange of the delta time series carry-over list from ÜNB to NB | ÜNB → NB | Transmission of the DZÜ list |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 202 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.