Check identifier 55035 — Response to GDA consuming MaLo
Check identifier 55035 · EDIFACT message type UTILMD · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 55035 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| BILANZIERUNG [ ] * | — | object[] | Must | — |
| detailsPrognosegrundlage 00010 | Forecast basis - If a day-parameter-dependent load profile with joint metering has to be specified, this is possible by repeating the CAV segment twice, stating the codes E02 and E14. | array | Must | — |
| prognosegrundlage * 00020 | Forecast basis | Enum Prognosegrundlage | Must | — |
WERTE | — | — | Must | — |
PROFILE | — | — | Must | — |
| jahresverbrauchsprognose | — | object | May | — |
| einheit 00030 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 00040 | Value | number (float) | X | — |
| lastprofile [ ] | — | object[] | May | — |
| bezeichnung 00050 | Designation of the profile | string | Must | — |
| einspeisung 00060 | Feed-in indicator | boolean | X | — |
| profilart 00070 | Profile category | Enum Profilart | X | — |
ART_STANDARDLASTPROFIL | — | — | X | — |
ART_TAGESPARAMETERABHAENGIGES_LASTPROFIL | — | — | X | — |
ART_LASTPROFIL | — | — | X | — |
| profilschar 00080 | Profile set of the profile | string | Must | — |
| verfahren 00090 | Profiling method | Enum Profilverfahren | X | — |
SYNTHETISCH | — | — | X | — |
ANALYTISCH | — | — | X | — |
| tagesparameter | — | object | May | — |
| dienstanbieter 00100 | dienstanbieter | string | Must | — |
| herausgeber 00110 | Herausgeber | Enum Herausgeber | Must | — |
NB | — | — | Must | — |
BDEW | — | — | Must | — |
TUM | — | — | Must | — |
| klimazone 00120 | klimazone | string | Must | — |
| temperaturmessstelle 00130 | temperaturmessstelle | string | Must | — |
| temperaturarbeit | — | object | May | — |
| einheit 00140 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | Must | — |
W | — | — | Must | — |
WH | — | — | Must | — |
KW | — | — | Must | — |
KWH | — | — | Must | — |
KVARH | — | — | Must | — |
MW | — | — | Must | — |
MWH | — | — | Must | — |
STUECK | — | — | Must | — |
KUBIKMETER | — | — | Must | — |
STUNDE | — | — | Must | — |
TAG | — | — | Must | — |
MONAT | — | — | Must | — |
JAHR | — | — | Must | — |
PROZENT | — | — | Must | — |
ANZAHL | — | — | Must | — |
VAR | — | — | Must | — |
KVAR | — | — | Must | — |
VARH | — | — | Must | — |
KWHK | — | — | Must | — |
Z16 | — | — | Must | — |
KWT | — | — | Must | — |
WATT_PRO_QUADRATMETER | — | — | Must | — |
METER_PRO_SEKUNDE | — | — | Must | — |
| wert 00150 | Value | number (float) | Must | — |
| LOKATIONSBUENDEL [ ] * | — | object[] | Must | — |
| lokationsbuendelNummer 00160 | lokationsbuendelNummer | integer | Must | — |
| lokationsbuendelstrukturId 00170 | lokationsbuendelstrukturId | string | Must | — |
| standardisierteLokationsbuendelstruktur * 00180 | standardisierteLokationsbuendelstruktur | boolean | Must | — |
| zuordnungObjectcode [ ] | — | object[] | May | — |
| referenzLokationsId 00190 | referenzLokationsId | string | Must | — |
| referenzLokationsTyp 00200 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| referenzMarktlokationTechnischeRessource 00210 | referenzMarktlokationTechnischeRessource | array | X | — |
| vorgelagerteLokationId 00220 | vorgelagerteLokationId | string | Must | — |
| vorgelagerteLokationTyp 00230 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| objectcode [ ] | — | object[] | May | — |
| lokationsbuendelNummer 00240 | lokationsbuendelNummer | integer | X | — |
| objectcode 00250 | objectcode | string | X | — |
| MARKTLOKATION [ ] * | — | object[] | Must | — |
| marktlokationsId * 00260 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| messtechnischeEinordnung * 00270 | Metering classification from the UTILMD (IMS, KME_MME, KEINE_MESSUNG) | Enum MesstechnischeEinordnung | Must | — |
IMS | — | — | Must | — |
KME_MME | — | — | Must | — |
KEINE_MESSUNG | — | — | Must | — |
| netzebene * 00280 | Grid level at which the energy is drawn. For electricity, the voltage level of the supply; for gas, the pressure level. Example electricity: low voltage Example gas: low pressure. | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| lokationsadresse | — | object | May | — |
| hausnummer 00290 | House number and supplement | string | X | — |
| landescode 00300 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00310 | City | string | X | — |
| ortsteil 00320 | District | string | X | — |
| postfach 00330 | PO box | string | X | — |
| postleitzahl 00340 | Postal code | string | X | — |
| strasse 00350 | Street | string | X | — |
| zusatzInformation | — | object | May | — |
| zusatz1 00360 | Address supplement 1 | string | X | — |
| zusatz2 00370 | Address supplement 2 | string | X | — |
| zusatz3 00380 | Address supplement 3 | string | X | — |
| zusatz4 00390 | Address supplement 4 | string | X | — |
| zusatz5 00400 | Address supplement 5 | string | X | — |
| marktrollen [ ] * | — | object[] | Must | — |
| marktrolle 00410 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00420 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer * 00430 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00440 | weiterverpflichtet | boolean | X | — |
| netznutzungsabrechnungsdaten [ ] * | — | object[] | Must | — |
| abschlag 00450 | Instalment payment | number (float) | Must | — |
| anzahl 00460 | Number | integer | X | — |
| artikelId * 00470 | artikelId | string | X | — |
| artikelIdTyp * 00480 | List of article IDs, e.g. for standardized articles issued by the BDEW that replace the BDEW article number in the electricity market | Enum ArtikelIdTyp | X | — |
ARTIKELID | — | — | X | — |
GRUPPENARTIKELID | — | — | X | — |
| gemeinderabatt * 00490 | Municipal discount | number (float) | X | [103] |
| zuschlag 00500 | Surcharge | number (float) | Must | — |
| preisSingulaereBetriebsmittel | — | object | May | — |
| wert 00510 | wert | number (float) | Must | — |
| singulaereBetriebsmittel | — | object | May | — |
| wert 00520 | Value | number (float) | X | — |
| zaehlzeiten | — | object | May | — |
| register 00530 | Metering time period register | string | X | — |
| zaehlzeitDefinition 00540 | Metering time period definition | string | X | — |
| technischeEinrichtungen [ ] | — | object[] | May | — |
| technischeEinrichtungenVorhanden 00550 | true => ZH7, false => ZH8 | boolean | Must | — |
| verbrauchsart 00560 | Consumption type | Enum Verbrauchsart | Must | — |
KL | — | — | Must | — |
W | — | — | Must | — |
EMOB | — | — | Must | — |
SB | — | — | Must | — |
SW | — | — | Must | — |
WK | — | — | Must | — |
| zaehlwerke [ ] * | — | object[] | Must | — |
| obisKennzahl * 00570 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| wertegranularitaet 00580 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| zaehlzeiten | — | object | May | — |
| register 00590 | Metering time period register | string | X | — |
| zaehlzeitDefinition 00600 | Metering time period definition | string | X | — |
| MESSLOKATION [ ] | — | object[] | May | — |
| messlokationsId 00610 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00620 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00630 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00640 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00650 | weiterverpflichtet | boolean | X | — |
| NETZLOKATION [ ] | — | object[] | May | — |
| konfigurationsprodukt 00660 | konfigurationsprodukt | string | X | — |
| leistungskurvendefinition 00670 | Code of the assigned power curve definition for the object | string | X | — |
| netzlokationsId 00680 | Identification number of a grid location at which energy is either consumed or generated (like MarktlokationsId market location) | string | X | — |
| steuerkanal 00690 | Whether a control channel is assigned to the grid location and the grid location can therefore be controlled. ZF2: No control channel present ZF3: Control channel present | boolean | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00700 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00710 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00720 | Specifies the code value of the market role. | string | X | — |
| STEUERBARE_RESSOURCE [ ] | — | object[] | May | — |
| keinKonfigurationsprodukt 00730 | keinKonfigurationsprodukt | boolean | X | — |
| konfigurationsprodukt 00740 | konfigurationsprodukt | string | X | — |
| ressourcenId 00750 | ressourcenId | string | X | — |
| steuerkanal 00760 | Control channel | Enum Steuerkanal | X | — |
AN_AUS | — | — | X | — |
GESTUFT | — | — | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00770 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00780 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00790 | Specifies the code value of the market role. | string | X | — |
| zugeordneteDefinition | — | object | May | — |
| leistungskurvendefinition 00800 | leistungskurvendefinition | string | Must | — |
| schaltzeitdefinition 00810 | schaltzeitdefinition | string | Must | — |
| TECHNISCHE_RESSOURCE [ ] | — | object[] | May | — |
| art 00820 | Technical resource type | Enum TechnischeRessourceArt | Must | — |
STROMERZEUGUNG | — | — | Must | — |
STROMVERBRAUCH | — | — | Must | — |
SPEICHER | — | — | Must | — |
| artEMobilitaet 00830 | ArtEmobilitaet | Enum ArtEmobilitaet | Must | — |
WB | — | — | Must | — |
LS | — | — | Must | — |
LP | — | — | Must | — |
| einordnung 00840 | RessourceWechselmoeglichkeit | Enum RessourceWechselmoeglichkeit | Must | — |
WECHSELMOEGLICHKEIT_EINMALIG_NOCH_MOEGLICH | — | — | Must | — |
WECHSELMOEGLICHKEIT_NICHT_MOEGLICH | — | — | Must | — |
BEFRISTET_OHNE_WECHSELMOEGLICHKEIT | — | — | Must | — |
WECHSEL_WURDE_DURCHGEFUEHRT | — | — | Must | — |
| enwg 00850 | enwg | boolean | Must | — |
| inbetriebsetzungsdatum 00860 | Commissioning | Enum Inbetriebsetzung | Must | — |
INBETRIEBSETZUNG_NACH_2023 | — | — | Must | — |
INBETRIEBSETZUNG_VOR_2024 | — | — | Must | — |
| referenzNetzlokation 00870 | referenzNetzlokation | string | X | — |
| referenzSteuerbareRessource 00880 | referenzSteuerbareRessource | string | X | — |
| ressourcenId 00890 | ressourcenId | string | X | — |
| speicherart 00900 | Type of storage. Details storage type Example: CAV+ZF7' Storage type: ZF7: hydrogen storage ZF8: pumped storage ZF9: battery storage ZG6: other storage type | Enum Speicherart | Must | — |
WASSERSTOFFSPEICHER | — | — | Must | — |
PUMPSPEICHER | — | — | Must | — |
BATTERIESPEICHER | — | — | Must | — |
SONSTIGE_SPEICHERART | — | — | Must | — |
| speicherkapazitaet 00910 | Storage capacity Example: QTY+Z42:100:KWH' | number (float) | X | — |
| verbrauchsart 00920 | Consumption type of the technical resource Example: CAV+Z64' Z64: Power/light Z65: Heat ZE5: E-mobility ZA8: Street lighting | array | Must | — |
| waermenutzung 00930 | Heat usage Example: CAV+Z56' Z56: Storage heating Z57: Heat pump Z61: Direct heating | Enum Waermenutzung | Must | — |
SPEICHERHEIZUNG | — | — | Must | — |
WAERMEPUMPE | — | — | Must | — |
DIREKTHEIZUNG | — | — | Must | — |
WAERMEPUMPE_WAERME_KAELTE | — | — | Must | — |
WAERMEPUMPE_KAELTE | — | — | Must | — |
WAERMEPUMPE_WAERME | — | — | Must | — |
| nennleistung | — | object | May | — |
| abgabe 00940 | Submission of the rated capacity | number (float) | X | — |
| aufnahme 00950 | Recording of the rated power | number (float) | X | — |
| ZAEHLER [ ] | — | object[] | May | — |
| gateway 00960 | Specification of a SMGW with which the meter is parameterised | string | X | — |
| messlokationsId 00970 | messlokationsId | string | X | — |
| messwerterfassung 00980 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| zaehlernummer 00990 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 01000 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 01010 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 01020 | The number printed on the device, which is assigned by the MSB. | string | Must | — |
| geraetetyp 01030 | List of possible billable device types | Enum Geraetetyp | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
ZWEIRICHTUNGSZAEHLER | — | — | Must | — |
RLM_ZAEHLER | — | — | Must | — |
IMS_ZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
MULTIPLEXANLAGE | — | — | Must | — |
PAUSCHALANLAGE | — | — | Must | — |
VERSTAERKERANLAGE | — | — | Must | — |
SUMMATIONSGERAET | — | — | Must | — |
IMPULSGEBER | — | — | Must | — |
EDL_21_ZAEHLERAUFSATZ | — | — | Must | — |
VIER_QUADRANTEN_LASTGANGZAEHLER | — | — | Must | — |
MENGENUMWERTER | — | — | Must | — |
STROMWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
DATENLOGGER | — | — | Must | — |
KOMMUNIKATIONSANSCHLUSS | — | — | Must | — |
MODEM | — | — | Must | — |
TELEKOMMUNIKATIONSEINRICHTUNG | — | — | Must | — |
KOMMUNIKATIONSEINRICHTUNG | — | — | Must | — |
DREHKOLBENGASZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MODERNE_MESSEINRICHTUNG | — | — | Must | — |
ELEKTRONISCHER_HAUSHALTSZAEHLER | — | — | Must | — |
STEUEREINRICHTUNG | — | — | Must | — |
TECHNISCHESTEUEREINRICHTUNG | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
OPTIONALE_ZUS_ZAEHLEINRICHTUNG | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER_IMS_MME | — | — | Must | — |
TARIFSCHALTGERAET_IMS_MME | — | — | Must | — |
RUNDSTEUEREMPFAENGER_IMS_MME | — | — | Must | — |
TEMPERATUR_KOMPENSATION | — | — | Must | — |
HOECHSTBELASTUNGS_ANZEIGER | — | — | Must | — |
SONSTIGES_GERAET | — | — | Must | — |
SMARTMETERGATEWAY | — | — | Must | — |
STEUERBOX | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
PLC_COM | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
WANDLER | — | — | Must | — |
BEFESTIGUNGSEINRICHTUNG | — | — | Must | — |
| zaehlwerke [ ] | — | object[] | May | — |
| konfiguration 01040 | Configuration (iMSys) of the meter register | string | X | — |
| obisKennzahl 01050 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| wertegranularitaet 01060 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer * 01070 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| dokumentennummer * 01080 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| kategorie * 01090 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 01100 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 01110 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 01120 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 01130 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| transaktionsgrundergaenzung * 01140 | Supplement to the transaction reason / UTILMD STS+7++E01+###+E03 | string | X | — |
| vorgangsnummer * 01150 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 01160 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 01170 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 01180 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 01190 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55035 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E4400070 | Information notification | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/ message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMM ZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document/message issuer or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00160 | Message recipient | — | X | — |
303900170 | MP-ID | — | X | — |
3055 900180 | GS1 | — | X | — |
3055 29300190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400200 | Transaction | — | X | — |
740200210 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700220 | Transaction reason | — | X | — |
9013 ZY700230 | Response to GDA consuming MaLo | — | X | — |
9013 ZW400240 | Consuming market location | — | X | — |
9013 ZAP00250 | dormant market location | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1800260 | Grid location | — | X | — |
322500270 | ID of the grid location | — | X | [960] |
| SG5.LOC | — | — | Must | — |
3227 Z1600280 | Market location | — | X | — |
322500290 | ID of the market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2200300 | Dormant market location | — | X | — |
322500310 | ID of the dormant market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2000320 | Technical resource | — | X | — |
322500330 | ID of the technical resource | — | X | [922] |
| SG5.LOC | — | — | Must | — |
3227 Z1900340 | Controllable resource | — | X | — |
322500350 | ID of the controllable resource | — | X | [961] |
| SG5.LOC | — | — | Must | — |
3227 Z1700360 | Metering location | — | X | — |
322500370 | ID of the metering location | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300380 | Check identifier | — | X | — |
1154 5503500390 | GPKE / Response to GDA for consuming MaLo | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 AAV00400 | Number of the request | — | X | — |
115400410 | Transaction number | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZD500420 | Informative reference to the location bundle structure | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3100430 | Location bundle structure | — | X | — |
1153 Z3900440 | No standardized location bundle structure available | — | X | — |
115400450 | ID of the location bundle structure | — | X | [333] |
115600460 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.SEQ | — | — | Must | — |
1229 ZD600470 | Informative assignment of location to the object code of the location bundle | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200480 | Grid location | — | X | — |
1153 Z1800490 | Market location | — | X | — |
1153 Z1900500 | Metering location | — | X | — |
1153 Z3700510 | Technical resource | — | X | — |
115400520 | ID of a location | — | X | ([451] ∧ [950]) ⊻ ([452] ∧ [951]) ⊻ ([450] ∧ [960]) ⊻ ([456] ∧ [922]) |
| SG8.RFF | — | — | Must | [2313] |
1153 Z3300530 | Object code of the location in the location bundle structure | — | X | — |
115400540 | Object code | — | X | — |
115600550 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.RFF | — | — | Must | ([176] ∧ (([173] ∧ [179]) ⊻ ([174] ∧ [175]))) ⊻ ([177] ∧ [178] ∧ [179]) |
1153 Z3400560 | upstream metering location | — | X | — |
1153 Z3500570 | upstream grid location | — | X | — |
115400580 | ID of a location | — | X | ([442] ∧ [951]) ⊻ ([440] ∧ [960]) |
| SG8.RFF | — | — | Must | [179] ∧ [291] |
1153 Z1600590 | assigned market location | — | X | — |
115400600 | ID of the market location | — | X | [950] |
| SG8.SEQ | — | — | Must | — |
1229 ZD700610 | Informative data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200620 | Grid location | — | X | — |
115400630 | ID of the grid location | — | X | [960] |
| SG10.CCI | — | — | Must | — |
7059 Z4900640 | Control channel | — | X | — |
7037 ZF200650 | No control channel available | — | X | — |
7037 ZF300660 | Control channel present | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB300670 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9100680 | MSB | — | X | — |
113100690 | MP-ID | — | X | — |
7110 Z3900700 | Default metering point operator | — | X | — |
7110 Z4000710 | Competitive metering point operator | — | X | — |
7110 Z4100720 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE000730 | Informative product data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200740 | Grid location | — | X | — |
115400750 | ID of a grid location | — | X | [960] |
| SG8.PIA | — | — | Must | — |
4347 500760 | Product identification | — | X | — |
714000770 | Configuration product code | — | X | [412] |
7143 Z1200780 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5300790 | Code of the power curve definition | — | X | — |
703700800 | Code of the power curve definition | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z9800810 | Informative data of the market location | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 26500820 | Estimated annual quantity total/ annual consumption forecast for specific energy for day-parameter-dependent market location | — | X | — |
6063 Z0800830 | Adjusted electrical energy in accordance with Annex D of the VDN guideline "Load profiles for interruptible consumption devices" | — | X | — |
606000840 | Quantity | — | X | [902] |
6411 Z1600850 | kWh/K (kilowatt hour/Kelvin) | — | X | [103] |
6411 KWH00860 | Kilowatt hour | — | X | [104] |
| SG9.QTY | — | — | Must | — |
6063 3100870 | Estimated annual quantity total | — | X | — |
606000880 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH00890 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB300900 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9000910 | ÜNB | — | X | — |
113100920 | MP-ID | — | X | — |
| SG10.CAV | — | — | Must | [345] |
7111 Z9100930 | MSB | — | X | — |
113100940 | MP-ID | — | X | — |
7110 Z3900950 | Default metering point operator | — | X | — |
7110 Z4000960 | Competitive metering point operator | — | X | — |
7110 Z4100970 | Fallback metering point operator | — | X | — |
7110 Z1900980 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2000990 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0301000 | Voltage level of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0301010 | Extra-high voltage | — | X | — |
7111 E0401020 | High voltage | — | X | — |
7111 E0501030 | Medium voltage | — | X | — |
7111 E0601040 | Low voltage | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z8301050 | Metering classification of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z5201060 | iMS | — | X | — |
7111 Z5301070 | kME / mME | — | X | — |
7111 Z6801080 | no measurement | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZC001090 | Forecast based on values | — | X | — |
7037 ZA601100 | Forecast based on profiles | — | X | — |
| SG10.CAV | — | — | Must | [21] ∧ ([2182] ⊻ ([90] ∧ [2183])) |
7111 E0201110 | SLP/SEP | — | X | [1P0..1] |
7111 E1401120 | TLP/TEP | — | X | [1P0..1] |
| SG8.SEQ | — | — | Must | — |
1229 ZE101130 | Informative grid usage billing data of the market location | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 Z0201140 | Group article ID / article ID | — | X | — |
714001150 | Product/service number | — | X | ([942] ([270] ⊻ [282]) ∧ [284]) ⊻ ([943] ([259] ⊻ [261]) ∧ [284]) ⊻ ([957] [285] ∧ [287]) ⊻ ([948] [286] ∧ [287]) |
7143 Z0901160 | Article ID | — | X | [393] ⊻ ([394] ∧ [397]) ⊻ [395] |
7143 Z1001170 | Group article ID | — | X | [392] ⊻ ([394] ∧ [398]) |
| SG9.QTY | — | — | Must | — |
6063 Z3801180 | Number of line items to be billed for the group article ID / article ID | — | X | — |
606001190 | Quantity | — | X | [914] ∧ [937] |
6411 H8701200 | Piece | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z1601210 | Municipal discount | — | X | — |
606001220 | Quantity | — | X | [902] ∧ [930] ∧ [938] |
6411 P101230 | Percent | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z3401240 | Surcharge | — | X | — |
6063 Z3501250 | Instalment payment | — | X | — |
6063 Z3701260 | No surcharge/discount | — | X | — |
606001270 | Quantity | — | X | ([914] ∧ [930] [140]) ⊻ ([926] ∧ [937] [172]) |
6411 P101280 | Percent | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z3301290 | Individually used equipment | — | X | — |
606001300 | Quantity | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z4401310 | Calculation price | — | X | — |
7037 ZD801320 | Day | — | X | — |
703601330 | Price, amount | — | X | [914] ∧ [946] |
| SG10.CCI | — | — | Must | — |
7059 Z3901340 | Code of the metering time period definition | — | X | — |
703701350 | Code of the metering time period definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3801360 | Code of the metering time period register | — | X | — |
703701370 | Code of the metering time period register | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE301380 | Informative OBIS data of the market location | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 501390 | Product identification | — | X | — |
714001400 | OBIS code of the market location | — | X | [314] |
7143 SRW01410 | OBIS code | — | X | — |
714301420 | Purpose of use NB | — | X | [381] |
1131 Z1601430 | EDI@Energy code list of purposes of us e | — | X | — |
714301440 | Purpose of use LF | — | X | [382] |
1131 Z1601450 | EDI@Energy code list of purposes of us e | — | X | — |
714301460 | Purpose of use ÜNB | — | X | [383] |
1131 Z1601470 | EDI@Energy code list of purposes of us e | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401480 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD901490 | Annually | — | X | — |
7111 ZE801500 | Semi-annual | — | X | — |
7111 ZE901510 | Quarterly | — | X | — |
7111 ZB701520 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3901530 | Code of the metering time period definition | — | X | — |
703701540 | Code of the metering time period definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3801550 | Code of the metering time period register | — | X | — |
703701560 | Code of the metering time period register | — | X | — |
| SG10.CAV | — | — | Must | [446] |
| SG8.SEQ | — | — | Must | — |
1229 ZF001570 | Informative data of the technical resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3701580 | Technical resource | — | X | — |
115401590 | ID of the technical resource | — | X | [922] |
| SG8.RFF | — | — | Should | [166] ∧ [699] |
1153 Z3801600 | Controllable resource | — | X | — |
115401610 | ID of the controllable resource | — | X | [961] |
| SG8.RFF | — | — | Should | [166] ∧ [700] |
1153 Z3201620 | Grid location | — | X | — |
115401630 | ID of the grid location | — | X | [960] |
| SG8.RFF | — | — | Should | [166] ∧ [447] ∧ [701] |
1153 Z2001640 | Tranche | — | X | — |
115401650 | ID of the tranche | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 Z4301660 | Rated power (input) | — | X | — |
606001670 | Quantity | — | X | — |
6411 KWT01680 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4401690 | Rated power (output) | — | X | — |
606001700 | Quantity | — | X | — |
6411 KWT01710 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4201720 | Storage capacity | — | X | — |
606001730 | Quantity | — | X | — |
6411 KWH01740 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1701750 | Type of electricity consumption | — | X | — |
7059 Z5601760 | Storage | — | X | — |
| SG10.CAV | — | — | Must | [446] |
7111 Z6401770 | Power/light | — | X | [1P0..1] |
7111 Z6501780 | Heat/cold | — | X | [1P0..1] |
7111 ZE501790 | E-mobility | — | X | [1P0..1] |
7111 ZA801800 | Street lighting | — | X | [1P0..1] |
| SG10.CAV | — | — | Must | [239] |
7111 Z5601810 | Storage heating | — | X | — |
7111 Z5701820 | Heat pump (unspecified) | — | X | — |
7111 Z6101830 | Direct heating | — | X | — |
7111 ZV501840 | Heat pump (heat and cold) | — | X | — |
7111 ZV601850 | Heat pump (cold) | — | X | — |
7111 ZV701860 | Heat pump (heat) | — | X | — |
| SG10.CAV | — | — | Must | [95] |
7111 ZE601870 | Wallbox | — | X | — |
7111 Z8701880 | E- mobility charging station | — | X | — |
7111 ZE701890 | Charging park | — | X | — |
| SG10.CAV | — | — | Must | [448] |
7111 ZF701900 | Hydrogen storage | — | X | — |
7111 ZF801910 | Pumped storage | — | X | — |
7111 ZF901920 | Battery storage | — | X | — |
7111 ZG601930 | Other storage type | — | X | — |
| SG10.CAV | — | — | Must | [446] ⊻ [448] |
7111 ZG801940 | Technical resource is covered by § 14a EnWG | — | X | — |
7111 ZG901950 | Technical resource is not covered by § 14a EnWG | — | X | — |
| SG10.CAV | — | — | Must | [461] |
7111 ZH001960 | Commissioning of the TR after 2023 | — | X | — |
7111 ZH101970 | Commissioning of the TR before 2024 | — | X | — |
| SG10.CAV | — | — | Must | [462] |
7111 ZH201980 | Option to change to the § 14a EnWG model pursuant to regulatory determination BK6-22-300 still available once | — | X | — |
7111 ZH301990 | Option to change to the § 14a EnWG model pursuant to regulatory determination BK6-22-300 not available | — | X | — |
7111 ZH402000 | Limited in time under the old § 14a EnWG model until 2028 without option to switch | — | X | — |
7111 ZH502010 | Change to the § 14a EnWG model pursuant to regulatory determination BK6-22-300 has been carried out | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF102020 | Informative data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3802030 | Controllable resource | — | X | — |
115402040 | ID of the controllable resource | — | X | [961] |
| SG10.CCI | — | — | Must | — |
7059 Z4902050 | Control channel | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF202060 | Service description of the control channel | — | X | — |
1131 Z1402070 | On/Off | — | X | — |
1131 Z1502080 | Tiered | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB302090 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9102100 | MSB | — | X | — |
113102110 | MP-ID | — | X | — |
7110 Z3902120 | Default metering point operator | — | X | — |
7110 Z4002130 | Competitive metering point operator | — | X | — |
7110 Z4102140 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF202150 | Informative product data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3802160 | Controllable resource | — | X | — |
115402170 | ID of a controllable resource | — | X | [961] |
| SG8.PIA | — | — | Must | [81] |
4347 502180 | Product identification | — | X | — |
714002190 | Configuration product code | — | X | — |
7143 Z1202200 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1102210 | Product | — | X | — |
7037 ZF602220 | No product assigned | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5202230 | Code of the switching time definition | — | X | — |
7059 Z5302240 | Code of the power curve definition | — | X | — |
703702250 | Code of the definition | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF302260 | Informative data of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1902270 | Metering location | — | X | — |
115402280 | ID of the metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 ZB302290 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9102300 | MSB | — | X | — |
113102310 | MP-ID | — | X | — |
7110 Z3902320 | Default metering point operator | — | X | — |
7110 Z4002330 | Competitive metering point operator | — | X | — |
7110 Z4102340 | Fallback metering point operator | — | X | — |
7110 Z1902350 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2002360 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF002370 | gMSB | — | X | — |
113102380 | MP-ID | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF502390 | Informative metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1902400 | Metering location | — | X | — |
115402410 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Should | [166] ∧ [215] |
1153 Z1402420 | Smart meter gateway | — | X | — |
115402430 | Identification / number of the smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1302440 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AHZ02450 | analog household meter (three-phase current) | — | X | — |
7111 WSZ02460 | analog alternating current meter | — | X | — |
7111 LAZ02470 | Load curve meter | — | X | — |
7111 MAZ02480 | Maximum demand meter | — | X | — |
7111 MME02490 | modern metering device according to MsbG | — | X | — |
7111 EHZ02500 | electronic household meter | — | X | — |
7111 IVA02510 | Individual reconciliation (special equipment) | — | X | — |
7110 Z0102520 | EDL40 | — | X | [136] |
7110 Z0202530 | EDL21 | — | X | [136] |
7110 Z0302540 | other EHZ | — | X | [136] |
7110 Z0402550 | Standard | — | X | [346] |
7110 Z0502560 | MeDa meter | — | X | [346] |
| SG10.CAV | — | — | Must | — |
7111 Z3002570 | Device number | — | X | — |
711002580 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1202590 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR02600 | remotely readable meters | — | X | — |
7111 MMR02610 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF602620 | Informative OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [665] |
1153 MG02630 | Device number of the meter | — | X | [441] |
1153 Z1402640 | Smart meter gateway | — | X | — |
115402650 | Device number | — | X | — |
| SG8.RFF | — | — | Must | [402] ∧ [420] |
1153 AGK02660 | Application reference number | — | X | — |
115402670 | Reference, identification | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 502680 | Product identification | — | X | — |
714002690 | OBIS code of the metering device | — | X | [323] |
7143 SRW02700 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE402710 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD902720 | Annually | — | X | — |
7111 ZE802730 | Semi-annual | — | X | — |
7111 ZE902740 | Quarterly | — | X | — |
7111 ZB702750 | Monthly | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZG002760 | Informative smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7502770 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3002780 | Device number | — | X | — |
711002790 | Device number | — | X | [952] |
| SG8.SEQ | — | — | Must | — |
1229 ZG102800 | Informative profile data | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0202810 | Standard load profile | — | X | — |
7037 E0102820 | synthetic method | — | X | — |
7037 Z1002830 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711102840 | Code of the standardized profile | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZG202850 | Informative profile set data | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z1202860 | Profile set | — | X | — |
| SG10.CAV | — | — | Must | — |
711102870 | Code of the profile set | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0302880 | day-parameter-dependent load profile | — | X | — |
7037 E0102890 | synthetic method | — | X | — |
7037 Z1002900 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711102910 | Code of the standardized profile | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z9902920 | Measuring station of the daily parameter (currently only the temperature is a permitted daily parameter) | — | X | — |
7059 ZA002930 | Climate zone of the daily parameter (currently is daily parameter) | — | X | — |
703702940 | ID of climate zone / temperature measuring point | — | X | — |
113102950 | Service provider | — | X | [58] |
3055 8902960 | Assigned by the trader (here grid operator) | — | X | — |
3055 29302970 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z6302980 | Informative market location address | — | X | — |
312402990 | Additional information for identification | — | — | — |
304203000 | Street and house number or PO box | — | — | S [166] M [212] |
316403010 | City | — | X | — |
325103020 | Postal code | — | X | — |
320703030 | Country name, code | — | X | — |
| UNT | — | — | Must | — |
007403040 | Number of segments in a message | — | X | — |
006203050 | Message reference number | — | X | — |
Conditions of this table
The free text of the 87 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [21] | If SG10 CCI+++ZA6 (forecast based on profiles) present in this SG8 |
| [32] | If more than one SG8 (reference to the location bundle structure) is present |
| [58] | If in this CCI the DE3055 with the code 293 is present |
| [81] | If in the same SG8 SEQ+Z61/ZB3/ZB4 (product data of the controllable resource) the SG10 CCI+11 (details on the product of the controllable resource) is not present |
| [90] | If SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) present once with CAV+E14 (TLP/TEP) and once with CAV+E02 (SLP/SEP) in this SG8 |
| [95] | If in the same SG10 the CCI+Z17 (type of electricity consumption ) CAV+ZE5 (e-mobility) is present |
| [103] | If SG9 QTY+265 (energy / power for day-parameter-dependent market location: estimated annual quantity total) present in this SG8 |
| [104] | If SG9 QTY+Z08 (energy / power for day-parameter-dependent market location: adjusted electrical energy according to Annex D) present in this SG8 |
| [136] | If SG10 CCI+++E13 (meter type) CAV+EHZ (electronic household meter) present in this SG8 |
| [140] | If Z34/Z35 (surcharge/instalment payment) is present in DE6063 in the same QTY |
| [166] | If present |
| [172] | If Z37 (no surcharge or instalment payment) is present in DE6063 in the same QTY |
| [173] | If DE1156 (consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is not present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [174] | If DE1156 consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [175] | If the object code in RFF+Z33 (reference to the object code in the location bundle struct ure) in DE1154 of the same SG8 SEQ+Z58 (assignment of location to the object code of the location bundle) is present in a further SG8 SEQ+Z58 with the same sequential number |
| [176] | If DE1153 with code Z34 upstream metering location is present in the same segment |
| [177] | If DE1153 with code Z35 upstream grid location is present in the same segment |
| [178] | If the LOC+Z18 (grid location) is present |
| [179] | If the object code in RFF+Z33 (reference to the object code in the location bundle struc ture) in DE1154 of the same SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle ) is present in a further SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle ) with an identical code in DE1229 |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [215] | If in the same SG8 (metering device data) SG10 CCI+++E13 CAV+MME (meter type: mME) is present |
| [239] | If in the same SG10 the CCI+Z17 (type of electricity consumption ) is present in the CAV+Z65 (heat/cooling) |
| [259] | If in this PIA the code in DE7140 contains 1- 01, 1-03, 1-05 |
| [261] | If in this PIA the code in DE7140 begins with 1- 07-1/2, 1-10-1/2/4/5/6/7/8/9, 1-11-1 |
| [270] | If in this PIA the code in DE7140 begins with 1- 02, 1-04, 1-06, 1-09 |
| [282] | If in this PIA the code in DE7140 contains 1-01-6- 005, 1-01-9-001/002, 1-07-3- 001, 1- 08-1-001, 1-08-3-001, 1-08-4-001/002/003/004, 1- 10-3-001 |
| [284] | Permitted codes from the code list of the group article and article ID are marked with X in the UTILMD/code usage column |
| [285] | If in this PIA the code in DE7140 is specified with 1- 08-3-AGS |
| [286] | If in this PIA the code in DE7140 with 1- 08-1/2/4/5-AGS-KG |
| [287] | Permitted codes from the PRICAT BGM+Z70 (price sheet for grid usage) of the responsible NB |
| [291] | If in the same SG8 (assignment of location to the object code of the location bundle ) the RFF+Z37 is present |
| [314] | All OBIS codes in accordance with the code list of OBIS codes and media, chapter 3, that are required at the market location must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document Code list of configurations |
| [323] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3., that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document "Code list of configurations" |
| [333] | If in this RFF "reference to the location bundle structure" the code Z31 "location bundle structure" is present in DE1153 |
| [345] | If SG5 LOC+Z17 (metering location) is present |
| [346] | If SG10 CCI+++E13 (meter type) CAV+MME (mME) present in this SG8 |
| [381] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/NB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [382] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/LF“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [383] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/ÜNB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [392] | If the code in this PIA is specified in the format n1-n2- n1 |
| [393] | If the code in this PIA is specified in the format n1-n2- n1-n3 |
| [394] | If the code in this PIA is specified in the format n1-n2- n1-n8-n2 |
| [395] | If the code in this PIA is specified in the format n1-n2- n1-n8 |
| [397] | If in this PIA the code in DE7140 begins with 1- 08-1/1-08-4 |
| [398] | If in this PIA the code in DE7140 begins with 1- 08-2/1-08-5 |
| [402] | If in the same SG8 (OBIS data of the metering device / smart meter gateway) an OBIS code of the value type "meter reading" is present in the PIA+5 |
| [412] | Only configuration product codes from the "EDI@Energy code list of configurations", chapter 4.2 Configuration products power curve definition, are permitted |
| [420] | If the RFF+Z14 (smart meter gateway) is present in this SG8 |
| [440] | If code Z35 (upstream grid location) is present in DE1153 in the same RFF |
| [441] | If RFF+Z14 (reference to the smart meter gateway) is not present in the SG8+SEQ+Z03/ZF5 (metering device data) for the device number of a meter named in this RFF DE1154 |
| [442] | If code Z34 (upstream metering location) is present in DE1153 in the same RFF |
| [446] | If in the same SG8 the CCI+Z17 (type of electricity consumption ) is present |
| [447] | If in the same SG8 the CCI+Z50 (type of electricity generation ) is present |
| [448] | If in the same SG8 the CCI+Z56 (storage) is present |
| [450] | If code Z32 (grid location) is present in DE1153 in the same RFF |
| [451] | If code Z18 (market location) is present in DE1153 in the same RFF |
| [452] | If code Z19 (metering location) is present in DE1153 in the same RFF |
| [456] | If code Z37 (technical resource) is present in DE1153 in the same RFF |
| [461] | If in the same SG10 the CCI (type and use of the technical resource) is present in the CAV+ZG8 (technical resource falls under § 14a EnWG) |
| [462] | If in the same SG10 the CCI+Z17 (type of electricity consumption ) is present in the CAV+ZH1 (commissioning of the TR before 2024) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [665] | Note: If a meter is parameterized with a SMGW, no OBIS code numbers are stated for that meter. Only OBIS code numbers from the SMGW exist here |
| [699] | Note: The ID of the controllable resource via which the technical resource is controlled must be specified |
| [700] | Note: The ID of the grid location via which the technical resource is controlled must be specified |
| [701] | Note: The Malo ID of the tranche to which the technical resource is assigned must be specified |
| [902] | Format: Possible value: ≥ 0 |
| [914] | Format: Possible value: > 0 |
| [922] | Format: TR-ID |
| [926] | Format: Possible value: 0 |
| [930] | Format: max. 2 decimal places |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [938] | Format: Possible value: <= 10 |
| [942] | Format: n1- n2-n1-n3 |
| [943] | Format: n1- n2-n1 |
| [946] | Format: max. 11 decimal places |
| [948] | Format: n1-n2-n1-n8- n2 |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [957] | Format: n1- n2-n1-n8 |
| [960] | Format: Grid location ID |
| [961] | Format: SR-ID |
| [2182] | Segment group must be specified exactly once per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2183] | Segment group must be specified exactly twice per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2313] | To be specified exactly once per SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of the location to the object code of the location bundle ) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
UNA:+.? '
UNB+UNOC:3+9900321000005:500+9903790000002:500+{{date}}:{{time}}+M37L81OQ'
UNH+UNHM3E13A90+UTILMD:D:11A:UN:S2.2'
BGM+E44+BGMM3RPZDFA'
DTM+137:202610021100?+00:303'
NAD+MS+9900321000005::293'
NAD+MR+9903790000002::293'
IDE+24+123456'
STS+7++ZY7+ZAP'
LOC+Z18+E1688117482'
LOC+Z16+50074561188'
LOC+Z22+50363198102'
LOC+Z20+D417MLM8164'
LOC+Z19+C816417ST77'
LOC+Z17+DE0032106765712000000000000000037'
RFF+Z13:55035'
RFF+AAV:ABC1234567'
SEQ+ZD5'
RFF+Z31:9992000000026'
SEQ+ZD6'
RFF+Z32:E1688117482'
RFF+Z33:9992000001256'
SEQ+ZD6'
RFF+Z18:50074561188'
RFF+Z33:9992000001016'
SEQ+ZD6'
RFF+Z19:DE0032106765712000000000000000037'
RFF+Z33:9992000001032'
SEQ+ZD6'
RFF+Z37:D417MLM8164'
RFF+Z33:9992000001024'
SEQ+ZD7'
RFF+Z32:E1688117482'
CCI+Z49++ZF2'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39'
SEQ+ZE0'
RFF+Z32:E1688117482'
PIA+5+9991000000721:Z12'
CCI+Z53++ABC'
SEQ+Z98'
QTY+31:2000:KWH'
CCI+++ZB3'
CAV+Z90:4045399000077'
CAV+Z91:9904446000007::Z39:Z19'
CCI+++E03'
CAV+E06'
CCI+++Z83'
CAV+Z53'
CCI+++ZA6'
CAV+E02'
SEQ+ZE1'
PIA+Z02+1-02-0-001:Z09'
QTY+Z16:0:P1'
QTY+Z37:0:P1'
SEQ+ZE3'
PIA+5+1-1?:1.9.0:SRW'
CCI+++ZE4'
CAV+ZD9'
SEQ+ZE4'
PIA+5+9991000000721:Z12'
CCI+Z53++ABC'
SEQ+ZF0'
RFF+Z37:D417MLM8164'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z43:1000:KWT'
QTY+Z44:500:KWT'
QTY+Z42:2000:KWH'
CCI+Z56'
CAV+ZG6'
CAV+ZG8'
CAV+ZH1'
CCI+Z63'
CAV+ZH8'
SEQ+ZF1'
RFF+Z38:C816417ST77'
CCI+Z49'
CAV+ZF2:Z14'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39'
SEQ+ZF2'
RFF+Z38:C816417ST77'
PIA+5+9991000000721:Z12'
CCI+Z53++ABC'
SEQ+ZF3'
RFF+Z19:DE0032106765712000000000000000037'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39:Z19'
CAV+ZF0:9904446000007'
SEQ+ZF5'
RFF+Z19:DE0032106765712000000000000000037'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::EL001IK01013852469'
CCI+++E12'
CAV+MMR'
SEQ+ZF6'
RFF+MG:EL001IK01013852469'
PIA+5+1-1?:1.8.0:SRW'
CCI+++ZE4'
CAV+ZD9'
SEQ+ZG1'
CCI+Z02++E01'
CAV+H0'
NAD+Z63++Mustermann:Max++Str::1+Ort++12345+DE'
UNT+105+UNHM3E13A90'
UNZ+1+M37L81OQ'[1 item
{6 fields
"data": {3 fields
"stammdaten": {9 fields
"MARKTLOKATION": [2 items
{14 fields
"marktlokationsTyp": [1 item
{1 field
"lokationsadresse": {6 fields
"zusatzInformation": {2 fields
"marktrollen": [2 items
{6 fields
{8 fields
"zaehlwerke": [1 item
{2 fields
"netznutzungsabrechnungsdaten": [1 item
{3 fields
{5 fields
"marktlokationsTyp": [1 item
{1 field
"NETZLOKATION": [1 item
{9 fields
"marktrollen": [1 item
{7 fields
"MESSLOKATION": [1 item
{6 fields
"marktrollen": [2 items
{8 fields
{6 fields
"TECHNISCHE_RESSOURCE": [1 item
{15 fields
"nennleistung": {2 fields
"STEUERBARE_RESSOURCE": [1 item
{9 fields
"marktrollen": [1 item
{7 fields
"zugeordneteDefinition": {1 field
"LOKATIONSBUENDEL": [1 item
{6 fields
"zuordnungObjectcode": [4 items
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
"NETZNUTZUNGSVERTRAG": [1 item
{6 fields
"ZAEHLER": [1 item
{10 fields
"zaehlwerke": [1 item
{2 fields
"geraete": [1 item
{1 field
"BILANZIERUNG": [1 item
{8 fields
"lastprofile": [1 item
{5 fields
"jahresverbrauchsprognose": {2 fields
"detailsPrognosegrundlage": [1 item
"transaktionsdaten": {13 fields
"absender": {4 fields
"empfaenger": {4 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Business data request | GPKE part 4 | Electricity | Step 2 |
| NB | NB | Business data request | GPKE part 4 | Electricity | Step 2 |
| MSB | MSB | Business data request | GPKE part 4 | Electricity | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response to GDA consum. MaLo |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 4 | Business data request | NB → LF | Response |
Transaction and responses
Role of this check identifier: response. Basis: the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Request: No reference recorded in the source. Neither the Prüfi table (reaktion_auf) nor the step sequence of the processes names the message that this response answers.
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfragereferenznummer | SG4.IDE+24.SG6.RFF+AAV | dokumentennummer |
RFF+AAV quotes the preceding message via its BGM; the target is the dokumentennummer of the request. Which request is meant is not determined on this page (see above) — the target field is thus named, but not proven.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 424 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type utilmd. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.