Check identifier 55169 — Confirmation of commitment request
Check identifier 55169 · EDIFACT message type UTILMD · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 55169 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| BILANZIERUNG [ ] | — | object[] | May | — |
| abwicklungsmodell 00010 | Processing model | Enum Abwicklungsmodell | Must | — |
MODELL_1_BILANZIERUNG_AN_MARKTLOKATION | — | — | Must | — |
MODELL_2_BILANZIERUNG_IM_BILANZIERUNGSGEBIET | — | — | Must | — |
| aggregationsverantwortung 00020 | Aggregation responsibility | Enum Aggregationsverantwortung | X | — |
UENB | — | — | X | — |
VNB | — | — | X | — |
| detailsPrognosegrundlage 00030 | Forecast basis - If a day-parameter-dependent load profile with joint metering has to be specified, this is possible by repeating the CAV segment twice, stating the codes E02 and E14. | array | Must | — |
| marktlokationsId 00040 | Which market location these balancing data apply to | string | X | — |
| prognosegrundlage 00050 | Forecast basis | Enum Prognosegrundlage | Must | — |
WERTE | — | — | Must | — |
PROFILE | — | — | Must | — |
| jahresverbrauchsprognose | — | object | May | — |
| einheit 00060 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 00070 | Value | number (float) | X | — |
| lastprofile [ ] | — | object[] | May | — |
| bezeichnung 00080 | Designation of the profile | string | Must | — |
| einspeisung 00090 | Feed-in indicator | boolean | Must | — |
| profilart 00100 | Profile category | Enum Profilart | Must | — |
ART_STANDARDLASTPROFIL | — | — | Must | — |
ART_TAGESPARAMETERABHAENGIGES_LASTPROFIL | — | — | Must | — |
ART_LASTPROFIL | — | — | Must | — |
| referenzprofilbezeichnung 00110 | Designation of the reference profile | string | Must | — |
| verfahren 00120 | Profiling method | Enum Profilverfahren | Must | — |
SYNTHETISCH | — | — | Must | — |
ANALYTISCH | — | — | Must | — |
| tagesparameter | — | object | May | — |
| dienstanbieter 00130 | dienstanbieter | string | Must | — |
| herausgeber 00140 | Herausgeber | Enum Herausgeber | Must | — |
NB | — | — | Must | — |
BDEW | — | — | Must | — |
TUM | — | — | Must | — |
| klimazone 00150 | klimazone | string | Must | — |
| temperaturmessstelle 00160 | temperaturmessstelle | string | Must | — |
| temperaturarbeit | — | object | May | — |
| einheit 00170 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | Must | — |
W | — | — | Must | — |
WH | — | — | Must | — |
KW | — | — | Must | — |
KWH | — | — | Must | — |
KVARH | — | — | Must | — |
MW | — | — | Must | — |
MWH | — | — | Must | — |
STUECK | — | — | Must | — |
KUBIKMETER | — | — | Must | — |
STUNDE | — | — | Must | — |
TAG | — | — | Must | — |
MONAT | — | — | Must | — |
JAHR | — | — | Must | — |
PROZENT | — | — | Must | — |
ANZAHL | — | — | Must | — |
VAR | — | — | Must | — |
KVAR | — | — | Must | — |
VARH | — | — | Must | — |
KWHK | — | — | Must | — |
Z16 | — | — | Must | — |
KWT | — | — | Must | — |
WATT_PRO_QUADRATMETER | — | — | Must | — |
METER_PRO_SEKUNDE | — | — | Must | — |
| wert 00180 | Value | number (float) | Must | — |
| ENERGIELIEFERVERTRAG [ ] | — | object[] | May | — |
| lokationsId 00190 | lokationsId | string | X | — |
| korrespondenzpartner | — | object | May | — |
| anrede 00200 | The form of address for the GePa, e.g. Mr. | string | X | — |
| name1 00210 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00220 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00230 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00240 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 00250 | House number and supplement | string | X | — |
| landescode 00260 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00270 | City | string | X | — |
| ortsteil 00280 | District | string | X | — |
| postfach 00290 | PO box | string | X | — |
| postleitzahl 00300 | Postal code | string | X | — |
| strasse 00310 | Street | string | X | — |
| vertragspartner2 [ ] | — | object[] | May | — |
| anrede 00320 | The form of address for the GePa, e.g. Mr. | string | X | — |
| geschaeftspartnerrolle 00330 | Role held by the business partner (e.g. prospect, customer). | array | X | — |
| name1 00340 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00350 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00360 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00370 | name4 | string | X | — |
| LOKATIONSBUENDEL [ ] * | — | object[] | Must | — |
| lokationsbuendelNummer 00380 | lokationsbuendelNummer | integer | Must | — |
| lokationsbuendelstrukturId 00390 | lokationsbuendelstrukturId | string | Must | — |
| standardisierteLokationsbuendelstruktur * 00400 | standardisierteLokationsbuendelstruktur | boolean | Must | — |
| zuordnungObjectcode [ ] | — | object[] | May | — |
| referenzLokationsId 00410 | referenzLokationsId | string | Must | — |
| referenzLokationsTyp 00420 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| referenzMarktlokationTechnischeRessource 00430 | referenzMarktlokationTechnischeRessource | array | X | — |
| vorgelagerteLokationId 00440 | vorgelagerteLokationId | string | Must | — |
| vorgelagerteLokationTyp 00450 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| objectcode [ ] | — | object[] | May | — |
| lokationsbuendelNummer 00460 | lokationsbuendelNummer | integer | X | — |
| objectcode 00470 | objectcode | string | X | — |
| MARKTLOKATION [ ] * | — | object[] | Must | — |
| energierichtung 00480 | Indicates whether energy is fed in or drawn (fed out). | Enum Energierichtung | X | — |
AUSSP | — | — | X | — |
EINSP | — | — | X | — |
| konfigurationsprodukt 00490 | konfigurationsprodukt | string | X | — |
| leistungskurvendefinition 00500 | Code of the assigned power curve definition for the object | string | X | — |
| marktlokationsId * 00510 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| messtechnischeEinordnung 00520 | Metering classification from the UTILMD (IMS, KME_MME, KEINE_MESSUNG) | Enum MesstechnischeEinordnung | Must | — |
IMS | — | — | Must | — |
KME_MME | — | — | Must | — |
KEINE_MESSUNG | — | — | Must | — |
| netzebene 00530 | Grid level at which the energy is drawn. For electricity, the voltage level of the supply; for gas, the pressure level. Example electricity: low voltage Example gas: low pressure. | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| produktdatenRelevanteRolle 00540 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| energieherkunft [ ] | — | object[] | May | — |
| erzeugungsart 00550 | Type of generation | Enum Erzeugungsart | Must | — |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00560 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00570 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00580 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00590 | weiterverpflichtet | boolean | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 00600 | messprodukt | string | X | — |
| obisKennzahl 00610 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| wertegranularitaet 00620 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| verwendungszwecke [ ] | — | object[] | May | — |
| marktrolle 00630 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| zweck 00640 | zweck | array | Must | — |
| zaehlzeiten | — | object | May | — |
| register 00650 | Metering time period register | string | X | — |
| zaehlzeitDefinition 00660 | Metering time period definition | string | X | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| betriebszustand 00670 | Operating state | Enum Betriebszustand | X | — |
GESPERRT_NICHT_ENTSPERREN | — | — | X | — |
GESPERRT | — | — | X | — |
REGELBETRIEB | — | — | X | — |
AUSSERHALB_REGELBETRIEB | — | — | X | — |
| datenqualitaet 00680 | Data quality | Enum Datenqualitaet | X | — |
ERWARTETE_DATEN | — | — | X | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | X | — |
INFORMATIVE_DATEN | — | — | X | — |
GUELTIGE_DATEN | — | — | X | — |
KEINE_DATEN | — | — | X | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | X | — |
KEINE_DATEN_ERWARTET | — | — | X | — |
DIFFERENZ_DATEN | — | — | X | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | X | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | X | — |
| messlokationsId * 00690 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| netzebenemessung 00700 | Grid level | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| referenzMarktlokationsId 00710 | referenzMarktlokationsId | string | X | — |
| verwendungsumfang 00720 | Scope of use | Enum Verwendungsumfang | X | — |
MESSLOKATION_PROZESSUAL_BEHANDELT | — | — | X | — |
MESSLOKATION_LOKATIONSBUENDEL | — | — | X | — |
| ablesekartenempfaenger * | — | object | Must | — |
| anrede 00730 | The form of address for the GePa, e.g. Mr. | string | X | — |
| gewerbekennzeichnung 00740 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | X | — |
| name1 * 00750 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00760 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00770 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00780 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 00790 | House number and supplement | string | X | — |
| landescode 00800 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00810 | City | string | X | — |
| ortsteil 00820 | District | string | X | — |
| postfach 00830 | PO box | string | X | — |
| postleitzahl 00840 | Postal code | string | X | — |
| strasse 00850 | Street | string | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00860 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00870 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00880 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00890 | weiterverpflichtet | boolean | X | — |
| messadresse | — | object | May | — |
| hausnummer 00900 | House number and supplement | string | X | — |
| landescode 00910 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00920 | City | string | X | — |
| ortsteil 00930 | District | string | X | — |
| postfach 00940 | PO box | string | X | — |
| postleitzahl 00950 | Postal code | string | X | — |
| strasse 00960 | Street | string | X | — |
| zusatzInformation | — | object | May | — |
| zusatz1 00970 | Address supplement 1 | string | X | — |
| zusatz2 00980 | Address supplement 2 | string | X | — |
| zusatz3 00990 | Address supplement 3 | string | X | — |
| zusatz4 01000 | Address supplement 4 | string | X | — |
| zusatz5 01010 | Address supplement 5 | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 01020 | messprodukt | string | X | — |
| notwendigkeitZweiteMessung 01030 | Necessity of second measurement | Enum NotwendigkeitZweiteMessung | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| werteuebermittlungVerwendungszweck 01040 | Purpose of use for value transmission | Enum WerteuebermittlungVerwendungszweck | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| zaehlzeiten | — | object | May | — |
| zaehlzeitDefinition 01050 | Metering time period definition | string | Must | — |
| MESSSTELLENBETRIEBSVERTRAG [ ] * | — | object[] | Must | — |
| lokationsId * 01060 | lokationsId | string | X | — |
| lokationsTyp * 01070 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | X | — |
MALO | — | — | X | — |
MELO | — | — | X | — |
NELO | — | — | X | — |
TECHNISCHE_RESSOURCE | — | — | X | — |
STEUERBARE_RESSOURCE | — | — | X | — |
TRANCHE | — | — | X | — |
MABIS_ZAEHLPUNKT | — | — | X | — |
| korrespondenzpartner * | — | object | Must | — |
| anrede 01080 | The form of address for the GePa, e.g. Mr. | string | X | — |
| name1 * 01090 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 01100 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 01110 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 01120 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 01130 | House number and supplement | string | X | — |
| landescode 01140 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 01150 | City | string | X | — |
| ortsteil 01160 | District | string | X | — |
| postfach 01170 | PO box | string | X | — |
| postleitzahl 01180 | Postal code | string | X | — |
| strasse 01190 | Street | string | X | — |
| vertragskonditionen | — | object | May | — |
| geplanteTurnusablesung | — | object | May | — |
| ableseZeitraum 01200 | ableseZeitraum | string | X | — |
| vertragspartner2 [ ] * | — | object[] | Must | — |
| anrede 01210 | The form of address for the GePa, e.g. Mr. | string | X | — |
| geschaeftspartnerrolle 01220 | Role held by the business partner (e.g. prospect, customer). | array | X | — |
| name1 * 01230 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 01240 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 01250 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 01260 | name4 | string | X | — |
| NETZLOKATION [ ] | — | object[] | May | — |
| konfigurationsprodukt 01270 | konfigurationsprodukt | string | X | — |
| leistungskurvendefinition 01280 | Code of the assigned power curve definition for the object | string | X | — |
| netzlokationsId 01290 | Identification number of a grid location at which energy is either consumed or generated (like MarktlokationsId market location) | string | X | — |
| produktdatenRelevanteRolle 01300 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| steuerkanal 01310 | Whether a control channel is assigned to the grid location and the grid location can therefore be controlled. ZF2: No control channel present ZF3: Control channel present | boolean | X | — |
| auftraggebenderMarktpartner | — | object | May | — |
| marktrolle 01320 | Indicates the designation of the market role in free text. | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| rollencodenummer 01330 | Specifies the code value of the market role. | string | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 01340 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 01350 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 01360 | Specifies the code value of the market role. | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| obisKennzahl 01370 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| verwendungszwecke [ ] | — | object[] | May | — |
| marktrolle 01380 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| zweck 01390 | zweck | array | Must | — |
| STEUERBARE_RESSOURCE [ ] | — | object[] | May | — |
| konfigurationsprodukt 01400 | konfigurationsprodukt | string | X | — |
| produktdatenRelevanteRolle 01410 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| ressourcenId 01420 | ressourcenId | string | X | — |
| steuerkanal 01430 | Control channel | Enum Steuerkanal | X | — |
AN_AUS | — | — | X | — |
GESTUFT | — | — | X | — |
| auftraggebenderMarktpartner | — | object | May | — |
| marktrolle 01440 | Indicates the designation of the market role in free text. | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| rollencodenummer 01450 | Specifies the code value of the market role. | string | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 01460 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 01470 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 01480 | Specifies the code value of the market role. | string | X | — |
| zugeordneteDefinition | — | object | May | — |
| leistungskurvendefinition 01490 | leistungskurvendefinition | string | Must | — |
| schaltzeitdefinition 01500 | schaltzeitdefinition | string | Must | — |
| TECHNISCHE_RESSOURCE [ ] | — | object[] | May | — |
| art 01510 | Technical resource type | Enum TechnischeRessourceArt | Must | — |
STROMERZEUGUNG | — | — | Must | — |
STROMVERBRAUCH | — | — | Must | — |
SPEICHER | — | — | Must | — |
| artEMobilitaet 01520 | ArtEmobilitaet | Enum ArtEmobilitaet | Must | — |
WB | — | — | Must | — |
LS | — | — | Must | — |
LP | — | — | Must | — |
| enwg 01530 | enwg | boolean | Must | — |
| erzeugungsart 01540 | Type of energy generation. Details generation type Example: CAV+ZF5' Generation type: ZF5: solar ZF6: wind ZG0: gas ZG1: water ZG5: other generation type | Enum Erzeugungsart | Must | — |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| referenzMarktlokation 01550 | referenzMarktlokation | string | X | — |
| referenzMesslokation 01560 | referenzMesslokation | string | X | — |
| referenzNetzlokation 01570 | referenzNetzlokation | string | X | — |
| referenzSteuerbareRessource 01580 | referenzSteuerbareRessource | string | X | — |
| ressourcenId 01590 | ressourcenId | string | X | — |
| speicherart 01600 | Type of storage. Details storage type Example: CAV+ZF7' Storage type: ZF7: hydrogen storage ZF8: pumped storage ZF9: battery storage ZG6: other storage type | Enum Speicherart | Must | — |
WASSERSTOFFSPEICHER | — | — | Must | — |
PUMPSPEICHER | — | — | Must | — |
BATTERIESPEICHER | — | — | Must | — |
SONSTIGE_SPEICHERART | — | — | Must | — |
| speicherkapazitaet 01610 | Storage capacity Example: QTY+Z42:100:KWH' | number (float) | X | — |
| verbrauchsart 01620 | Consumption type of the technical resource Example: CAV+Z64' Z64: Power/light Z65: Heat ZE5: E-mobility ZA8: Street lighting | array | Must | — |
| waermenutzung 01630 | Heat usage Example: CAV+Z56' Z56: Storage heating Z57: Heat pump Z61: Direct heating | Enum Waermenutzung | Must | — |
SPEICHERHEIZUNG | — | — | Must | — |
WAERMEPUMPE | — | — | Must | — |
DIREKTHEIZUNG | — | — | Must | — |
WAERMEPUMPE_WAERME_KAELTE | — | — | Must | — |
WAERMEPUMPE_KAELTE | — | — | Must | — |
WAERMEPUMPE_WAERME | — | — | Must | — |
| weitereEinrichtung 01640 | weitereEinrichtung | boolean | Must | — |
| nennleistung | — | object | May | — |
| abgabe 01650 | Submission of the rated capacity | number (float) | X | — |
| aufnahme 01660 | Recording of the rated power | number (float) | X | — |
| TRANCHE [ ] | — | object[] | May | — |
| bildungTranchengroesse 01670 | BildungTranchengroesse | Enum BildungTranchengroesse | X | — |
PROZENTUAL | — | — | X | — |
AUFTEILUNGSFAKTOR | — | — | X | — |
AUFTEILUNG_TECHNISCHE_RESSOURCEN | — | — | X | — |
BERECHNUNGSFORMEL | — | — | X | — |
| referenzMarktlokationsId 01680 | referenzMarktlokationsId | string | X | — |
| tranchenId 01690 | tranchenId | string | X | — |
| aufteilungsmenge | — | object | May | — |
| einheit 01700 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 01710 | Value | number (float) | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 01720 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| rollencodenummer 01730 | Specifies the code value of the market role. | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 01740 | messprodukt | string | X | — |
| verwendungszwecke [ ] | — | object[] | May | — |
| marktrolle 01750 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| zweck 01760 | zweck | array | Must | — |
| ZAEHLER [ ] | — | object[] | May | — |
| befestigungsart 01770 | Mounting type | Enum Befestigungsart | Must | — |
STECKTECHNIK | — | — | Must | — |
DREIPUNKT | — | — | Must | — |
HUTSCHIENE | — | — | Must | — |
EINSTUTZEN | — | — | Must | — |
ZWEISTUTZEN | — | — | Must | — |
| fernschaltung 01780 | Remote switching | Enum Fernschaltung | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| gateway 01790 | Specification of a SMGW with which the meter is parameterised | string | X | — |
| marktlokationsId 01800 | marktlokationsId | string | X | — |
| messlokationsId 01810 | messlokationsId | string | X | — |
| messwerterfassung 01820 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| tarifart 01830 | Specification regarding supported tariff types. | Enum Tarifart | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
SMART_METER | — | — | Must | — |
LEISTUNGSGEMESSEN | — | — | Must | — |
| zaehlerauspraegung 01840 | Specification regarding the direction of the meter. | Enum Zaehlerauspraegung | Must | — |
EINRICHTUNGSZAEHLER | — | — | Must | — |
ZWEIRICHTUNGSZAEHLER | — | — | Must | — |
| zaehlernummer 01850 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 01860 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 01870 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 01880 | The number printed on the device, which is assigned by the MSB. | string | X | — |
| geraetetyp 01890 | List of possible billable device types | Enum Geraetetyp | X | — |
WECHSELSTROMZAEHLER | — | — | X | — |
DREHSTROMZAEHLER | — | — | X | — |
ZWEIRICHTUNGSZAEHLER | — | — | X | — |
RLM_ZAEHLER | — | — | X | — |
IMS_ZAEHLER | — | — | X | — |
BALGENGASZAEHLER | — | — | X | — |
MAXIMUMZAEHLER | — | — | X | — |
MULTIPLEXANLAGE | — | — | X | — |
PAUSCHALANLAGE | — | — | X | — |
VERSTAERKERANLAGE | — | — | X | — |
SUMMATIONSGERAET | — | — | X | — |
IMPULSGEBER | — | — | X | — |
EDL_21_ZAEHLERAUFSATZ | — | — | X | — |
VIER_QUADRANTEN_LASTGANGZAEHLER | — | — | X | — |
MENGENUMWERTER | — | — | X | — |
STROMWANDLER | — | — | X | — |
SPANNUNGSWANDLER | — | — | X | — |
DATENLOGGER | — | — | X | — |
KOMMUNIKATIONSANSCHLUSS | — | — | X | — |
MODEM | — | — | X | — |
TELEKOMMUNIKATIONSEINRICHTUNG | — | — | X | — |
KOMMUNIKATIONSEINRICHTUNG | — | — | X | — |
DREHKOLBENGASZAEHLER | — | — | X | — |
TURBINENRADGASZAEHLER | — | — | X | — |
ULTRASCHALLZAEHLER | — | — | X | — |
WIRBELGASZAEHLER | — | — | X | — |
MODERNE_MESSEINRICHTUNG | — | — | X | — |
ELEKTRONISCHER_HAUSHALTSZAEHLER | — | — | X | — |
STEUEREINRICHTUNG | — | — | X | — |
TECHNISCHESTEUEREINRICHTUNG | — | — | X | — |
TARIFSCHALTGERAET | — | — | X | — |
RUNDSTEUEREMPFAENGER | — | — | X | — |
OPTIONALE_ZUS_ZAEHLEINRICHTUNG | — | — | X | — |
MESSWANDLERSATZ_IMS_MME | — | — | X | — |
KOMBIMESSWANDLER_IMS_MME | — | — | X | — |
TARIFSCHALTGERAET_IMS_MME | — | — | X | — |
RUNDSTEUEREMPFAENGER_IMS_MME | — | — | X | — |
TEMPERATUR_KOMPENSATION | — | — | X | — |
HOECHSTBELASTUNGS_ANZEIGER | — | — | X | — |
SONSTIGES_GERAET | — | — | X | — |
SMARTMETERGATEWAY | — | — | X | — |
STEUERBOX | — | — | X | — |
BLOCKSTROMWANDLER | — | — | X | — |
KOMBIMESSWANDLER | — | — | X | — |
MODEM_GSM | — | — | X | — |
ETHERNET_KOM | — | — | X | — |
PLC_COM | — | — | X | — |
MODEM_FESTNETZ | — | — | X | — |
DSL_KOM | — | — | X | — |
LTE_KOM | — | — | X | — |
DICHTEMENGENUMWERTER | — | — | X | — |
TEMPERATURMENGENUMWERTER | — | — | X | — |
ZUSTANDSMENGENUMWERTER | — | — | X | — |
MESSDATENREGISTRIERGERAET | — | — | X | — |
WANDLER | — | — | X | — |
BEFESTIGUNGSEINRICHTUNG | — | — | X | — |
| weitereGeraetenummern 01900 | weitereGeraetenummern | array | X | — |
| geraeteeigenschaften | — | object | May | — |
| faktor 01910 | faktor | number (float) | Must | — |
| geraetemerkmal 01920 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlwerke [ ] | — | object[] | May | — |
| bezeichnung 01930 | Additional designation, e.g. Zählwerk_Wirkarbeit. | string | Must | — |
| konfiguration 01940 | Configuration (iMSys) of the meter register | string | X | — |
| nachkommastelle 01950 | nachkommastelle | integer | Must | — |
| obisKennzahl 01960 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| vorkommastelle 01970 | vorkommastelle | integer | Must | — |
| wertegranularitaet 01980 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer * 01990 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| antwortstatus * 02000 | Response status / STS+E01 | string | X | — |
| antwortstatusCodeliste * 02010 | Response status code list / STS+E01 | string | X | — |
| datumleistungsbeginn * 02020 | Date of the planned start of service / DTM+76 | string (date-time) | X | — |
| dokumentennummer * 02030 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| kategorie * 02040 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 02050 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 02060 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 02070 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 02080 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vorgangsnummer * 02090 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 02100 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 02110 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 02120 | Email address | string | Must | — |
| nachname 02130 | Surname (family name) of the contact person | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 02140 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 02150 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 02160 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 02170 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55169 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0100070 | Registrations | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00160 | Information contact | — | X | — |
341200170 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800180 | Number / address | — | X | (([939] [321]) ∨ ([940] [322])) ∧ [514] |
3155 EM00190 | Electronic mail | — | X | [1P0..1] |
3155 FX00200 | Fax number | — | X | [1P0..1] |
3155 TE00210 | Telephone | — | X | [1P0..1] |
3155 AJ00220 | further telephone | — | X | [1P0..1] |
3155 AL00230 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00240 | Message recipient | — | X | — |
303900250 | MP-ID | — | X | — |
3055 900260 | GS1 | — | X | — |
3055 29300270 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400280 | Transaction | — | X | — |
740200290 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 7600300 | Delivery date/time, scheduled | — | X | — |
238000310 | Date or time or time span, value | — | X | [UB1] |
2379 30300320 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700330 | Transaction reason | — | X | — |
9013 E0100340 | Move-in/move-out (relocation) | — | X | — |
9013 E0200350 | Move-in to creation | — | X | — |
9013 E0300360 | Change | — | X | — |
| SG4.STS | — | — | Must | [249] |
9015 E0100370 | Status of the response | — | X | — |
901300380 | Code of the check step | — | X | — |
1131 S_006300390 | Electricity code list no. S_0063 | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1800400 | Grid location | — | X | — |
322500410 | ID of the grid location | — | X | [960] |
| SG5.LOC | — | — | Must | — |
3227 Z1600420 | Market location | — | X | — |
322500430 | ID of the market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2000440 | Technical resource | — | X | — |
322500450 | ID of the technical resource | — | X | [922] |
| SG5.LOC | — | — | Must | — |
3227 Z1900460 | Controllable resource | — | X | — |
322500470 | ID of the controllable resource | — | X | [961] |
| SG5.LOC | — | — | Must | — |
3227 Z2100480 | Tranche | — | X | — |
322500490 | ID of the tranche | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z1700500 | Metering location | — | X | — |
322500510 | ID of the metering location | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300520 | Check identifier | — | X | — |
1154 5516900530 | WiM electricity / confirmation of commitment request | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00540 | Transaction reference number | — | X | — |
115400550 | Transaction number | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 Z5000560 | Scheduling data of the market location | — | X | — |
115400570 | ID of the market location / reference to time period ID | — | X | [950] |
| SG6.DTM | — | — | Must | [86] ∧ [271] |
2005 75200580 | Periodic meter reading | — | X | — |
238000590 | Date or time or time span, value | — | X | — |
2379 10400600 | MMWW-MMWW | — | X | — |
2379 10600610 | MMDD | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z7800620 | Reference to the location bundle structure | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3100630 | Location bundle structure | — | X | — |
1153 Z3900640 | No standardized location bundle structure available | — | X | — |
115400650 | ID of the location bundle structure | — | X | [333] |
115600660 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.SEQ | — | — | Must | — |
1229 Z5800670 | Assignment of the location to the object code of the location bundle | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200680 | Grid location | — | X | — |
1153 Z1800690 | Market location | — | X | — |
1153 Z1900700 | Metering location | — | X | — |
1153 Z3700710 | Technical resource | — | X | — |
115400720 | ID of a location | — | X | ([451] ∧ [950]) ⊻ ([452] ∧ [951]) ⊻ ([450] ∧ [960]) ⊻ ([456] ∧ [922]) |
| SG8.RFF | — | — | Must | [2312] |
1153 Z3300730 | Object code of the location in the location bundle structure | — | X | — |
115400740 | Object code | — | X | — |
115600750 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.RFF | — | — | Must | ([176] ∧ (([173] ∧ [179]) ⊻ ([174] ∧ [175]))) ⊻ ([177] ∧ [178] ∧ [179]) |
1153 Z3400760 | upstream metering location | — | X | — |
1153 Z3500770 | upstream grid location | — | X | — |
115400780 | ID of a location | — | X | ([442] ∧ [951]) ⊻ ([440] ∧ [960]) |
| SG8.RFF | — | — | Must | [179] ∧ [291] |
1153 Z1600790 | assigned market location | — | X | — |
115400800 | ID of the market location | — | X | [950] |
| SG8.SEQ | — | — | Must | — |
1229 Z5100810 | Data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200820 | Grid location | — | X | — |
115400830 | ID of the grid location | — | X | [960] |
| SG10.CCI | — | — | Must | — |
7059 Z4900840 | Control channel | — | X | — |
7037 ZF200850 | No control channel available | — | X | — |
7037 ZF300860 | Control channel present | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB300870 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9100880 | MSB | — | X | — |
113100890 | MP-ID | — | X | — |
7110 Z3900900 | Default metering point operator | — | X | — |
7110 Z4000910 | Competitive metering point operator | — | X | — |
7110 Z4100920 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z5700930 | OBIS data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200940 | Grid location | — | X | — |
115400950 | ID of the grid location | — | X | [960] |
| SG8.PIA | — | — | Must | — |
4347 500960 | Product identification | — | X | — |
714000970 | OBIS code of the grid location | — | X | — |
7143 SRW00980 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA800990 | NB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD101000 | Reactive energy billing / operational management | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA701010 | LF | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z4701020 | End customer billing | — | X | [1P1..1] |
7111 ZD101030 | Reactive energy billing / operational management | — | X | [1P1..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z6001040 | Product data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3201050 | Grid location | — | X | — |
115401060 | ID of a grid location | — | X | [960] |
| SG8.PIA | — | — | Must | — |
4347 501070 | Product identification | — | X | — |
714001080 | Configuration product code | — | X | [412] |
7143 Z1201090 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5301100 | Code of the power curve definition | — | X | — |
703701110 | Code of the power curve definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB301120 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8801130 | NB | — | X | — |
7111 Z8901140 | LF | — | X | — |
113101150 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA701160 | LF | — | X | [1P0..1] |
7037 ZA801170 | NB | — | X | [1P0..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z0101180 | Data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801190 | Market location | — | X | — |
115401200 | ID of the market location | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 26501210 | Estimated annual quantity total/annual consumption forecast for specific energy for day-parameter-dependent market location | — | X | — |
6063 Z0801220 | Adjusted electrical energy in accordance with Annex D of the VDN guideline "Load profiles for interruptible consumption devices" | — | X | — |
606001230 | Quantity | — | X | [902] |
6411 Z1601240 | kWh/K (kilowatt hour/Kelvin) | — | X | [103] |
6411 KWH01250 | Kilowatt hour | — | X | [104] |
| SG9.QTY | — | — | Must | — |
6063 3101260 | Estimated annual quantity total | — | X | — |
606001270 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH01280 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3001290 | Delivery direction | — | X | — |
7037 Z0601300 | Generation | — | X | — |
7037 Z0701310 | Consumption | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB301320 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | [78] ∧ [221] |
7111 Z8901330 | LF | — | X | — |
113101340 | MP-ID | — | X | [611] |
| SG10.CAV | — | — | Must | — |
7111 Z9001350 | ÜNB | — | X | — |
113101360 | MP-ID | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9101370 | MSB | — | X | — |
113101380 | MP-ID | — | X | [621] |
7110 Z3901390 | Default metering point operator | — | X | — |
7110 Z4001400 | Competitive metering point operator | — | X | — |
7110 Z4101410 | Fallback metering point operator | — | X | — |
7110 Z1901420 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2001430 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0301440 | Voltage level of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0301450 | Extra-high voltage | — | X | — |
7111 E0401460 | High voltage | — | X | — |
7111 E0501470 | Medium voltage | — | X | — |
7111 E0601480 | Low voltage | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z8301490 | Metering classification of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z5201500 | iMS | — | X | — |
7111 Z5301510 | kME / mME | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 601520 | Responsible party | — | X | — |
7037 ZA801530 | NB | — | X | — |
7037 ZA901540 | ÜNB | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZC001550 | Forecast based on values | — | X | — |
7037 ZA601560 | Forecast based on profiles | — | X | — |
| SG10.CAV | — | — | Must | [210] ∧ ([2182] ⊻ ([90] ∧ [2183])) |
7111 E0201570 | SLP/SEP | — | X | [1P0..1] |
7111 E1401580 | TLP/TEP | — | X | [1P0..1] |
7111 Z3601590 | TEP with reference measurement | — | X | [1P0..1] |
| SG10.CCI | — | — | Must | — |
7037 Z3401600 | Type of the generating market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3301610 | EEG market location without DV obligation | — | X | — |
7111 Z3401620 | KWKG market location without DV obligation | — | X | — |
7111 Z3501630 | other market location | — | X | — |
7111 Z3701640 | EEG market location with DV obligation | — | X | — |
7111 Z4601650 | KWKG market location with DV obligation | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 ZA201660 | Processing model | — | X | — |
7037 ZE901670 | Model 1 "Balancing at the market location" | — | X | — |
7037 ZF001680 | Model 2 "Balancing in the balancing area (BG) of the LPB" | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2701690 | Required metering product of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801700 | Market location | — | X | — |
115401710 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 501720 | Product identification | — | X | — |
714001730 | Metering product code | — | X | [425] |
7143 Z1101740 | Product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3901750 | Code of the metering time period definition | — | X | — |
7059 Z4101760 | No metering time period required for metering product | — | X | [417] |
703701770 | Code of the metering time period definition | — | X | [438] |
| SG10.CCI | — | — | Must | — |
7037 ZA801780 | NB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8401790 | Grid usage settlement | — | X | [19P1..1] ⊻ [20P1..1] ⊻ [22P1..1] ⊻ [26P1..1] |
7111 Z8501800 | Balancing group settlement | — | X | [21P0..1] ⊻ [22P0..1] ⊻ [23P0..1] ⊻ [24P0..1] |
7111 Z8601810 | Excess/shortfall quantity settlement | — | X | [20P1..1] ⊻ [27P1..1] |
7111 Z9201820 | Transmission to the HKNR | — | X | [23P1..1] ⊻ [24P1..1] |
7111 ZE101830 | There is no purpose of use | — | X | [38P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA701840 | LF | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8401850 | Grid usage settlement | — | X | [19P0..1] ⊻ [20P0..1] ⊻ [22P0..1] ⊻ [26P0..1] |
7111 Z8501860 | Balancing group settlement | — | X | [21P1..1] ⊻ [22P1..1] ⊻ [23P1..1] ⊻ [24P1..1] |
7111 Z8601870 | Excess/shortfall quantity settlement | — | X | [20P1..1] ⊻ [27P1..1] |
7111 Z4701880 | End customer billing | — | X | [19P1..1] ⊻ [20P0..1] ⊻ [22P1..1] ⊻ [24P1..1] ⊻ [25P1..1] ⊻ [26P0..1] ⊻ [27P1..1] |
7111 ZE101890 | There is no purpose of use | — | X | [38P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA901900 | ÜNB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8501910 | Balancing group settlement | — | X | [1P0..1] |
7111 ZB501920 | For the determination of the balance of balancing groups | — | X | [1P1..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z0201930 | OBIS data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801940 | Market location | — | X | — |
115401950 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 501960 | Product identification | — | X | — |
714001970 | OBIS code of the market location | — | X | [314] |
7143 SRW01980 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401990 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD902000 | Annually | — | X | — |
7111 ZE802010 | Semi-annual | — | X | — |
7111 ZE902020 | Quarterly | — | X | — |
7111 ZB702030 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3902040 | Code of the metering time period definition | — | X | — |
703702050 | Code of the metering time period definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3802060 | Code of the metering time period register | — | X | — |
703702070 | Code of the metering time period register | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA802080 | NB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8402090 | Grid usage settlement | — | X | [29P1..1] ⊻ [30P1..1] ⊻ [32P1..1] ⊻ [36P1..1] |
7111 Z8502100 | Balancing group settlement | — | X | [31P0..1] ⊻ [32P0..1] ⊻ [33P0..1] ⊻ [34P0..1] |
7111 Z8602110 | Excess/shortfall quantity settlement | — | X | [30P1..1] ⊻ [37P1..1] |
7111 Z9202120 | Transmission to the HKNR | — | X | [33P1..1] ⊻ [34P1..1] |
7111 ZE102130 | There is no purpose of use | — | X | [38P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA702140 | LF | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8402150 | Grid usage settlement | — | X | [29P0..1] ⊻ [30P0..1] ⊻ [32P0..1] ⊻ [36P0..1] |
7111 Z8502160 | Balancing group settlement | — | X | [31P1..1] ⊻ [32P1..1] ⊻ [33P1..1] ⊻ [34P1..1] |
7111 Z8602170 | Excess/shortfall quantity settlement | — | X | [30P1..1] ⊻ [37P1..1] |
7111 Z4702180 | End customer billing | — | X | [28P0..1] ⊻ [29P1..1] ⊻ [30P0..1] ⊻ [32P1..1] ⊻ [34P1..1] ⊻ [35P1..1] ⊻ [36P0..1] ⊻ [37P1..1] |
7111 ZE102190 | There is no purpose of use | — | X | [38P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA902200 | ÜNB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8502210 | Balancing group settlement | — | X | [1P0..1] |
7111 ZB502220 | For the determination of the balance of balancing groups | — | X | [1P1..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z5902230 | Product data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1802240 | Market location | — | X | — |
115402250 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 502260 | Product identification | — | X | — |
714002270 | Product/service number | — | X | — |
7143 Z1202280 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5302290 | Code of the power curve definition | — | X | — |
703702300 | Code of the definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA802310 | NB | — | X | [1P0..1] |
7037 ZA702320 | LF | — | X | [1P0..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z1502330 | Data of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2002340 | Tranche | — | X | — |
115402350 | ID of the tranche | — | X | [950] |
| SG8.RFF | — | — | Must | — |
1153 Z1602360 | assigned market location | — | X | — |
115402370 | ID of the market location | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 1102380 | Distribution quantity | — | X | — |
606002390 | Quantity specification in % | — | X | [914] ∧ [930] ∧ [955] |
6411 P102400 | Percent | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB302410 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8902420 | LF | — | X | — |
113102430 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3702440 | Basis for determining the tranche size | — | X | — |
7037 ZD102450 | Percentage-based | — | X | — |
7037 ZD202460 | Distribution factor based on reference carrier/installed capacity | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1602470 | Required product of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2002480 | Tranche | — | X | — |
115402490 | ID of a tranche | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 502500 | Product identification | — | X | — |
714002510 | Metering product code | — | X | [426] |
7143 Z1102520 | Product | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA802530 | NB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8502540 | Balancing group settlement | — | X | [1P0..1] |
7111 Z9202550 | Transmission to the HKNR | — | X | [1P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA702560 | LF | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8502570 | Balancing group settlement | — | X | [1P1..1] |
7111 Z4702580 | End customer billing | — | X | [1P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA902590 | ÜNB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8502600 | Balancing group settlement | — | X | [1P0..1] |
7111 ZB502610 | For the determination of the balance of balancing groups | — | X | [1P1..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z5202620 | Data of the technical resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3702630 | Technical resource | — | X | — |
115402640 | ID of the technical resource | — | X | [922] |
| SG8.RFF | — | — | Should | [166] ∧ [668] |
1153 Z3402650 | upstream metering location | — | X | — |
115402660 | ID of a location | — | X | [951] |
| SG8.RFF | — | — | Must | [668] |
1153 Z1602670 | assigned market location | — | X | — |
115402680 | ID of the market location | — | X | [950] |
| SG8.RFF | — | — | Should | [166] ∧ [699] |
1153 Z3802690 | Controllable resource | — | X | — |
115402700 | ID of the controllable resource | — | X | [961] |
| SG8.RFF | — | — | Should | [166] ∧ [700] |
1153 Z3202710 | Grid location | — | X | — |
115402720 | ID of the grid location | — | X | [960] |
| SG9.QTY | — | — | Must | — |
6063 Z4302730 | Rated power (input) | — | X | — |
606002740 | Quantity | — | X | — |
6411 KWT02750 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4402760 | Rated power (output) | — | X | — |
606002770 | Quantity | — | X | — |
6411 KWT02780 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4202790 | Storage capacity | — | X | — |
606002800 | Quantity | — | X | — |
6411 KWH02810 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1702820 | Type of electricity consumption | — | X | — |
7059 Z5002830 | Type of electricity generation | — | X | — |
7059 Z5602840 | Storage | — | X | — |
| SG10.CAV | — | — | Must | [446] |
7111 Z6402850 | Power/light | — | X | [1P0..1] |
7111 Z6502860 | Heat/cold | — | X | [1P0..1] |
7111 ZE502870 | E-mobility | — | X | [1P0..1] |
7111 ZA802880 | Street lighting | — | X | [1P0..1] |
| SG10.CAV | — | — | Must | [239] |
7111 Z5602890 | Storage heating | — | X | — |
7111 Z5702900 | Heat pump (unspecified) | — | X | — |
7111 Z6102910 | Direct heating | — | X | — |
7111 ZV502920 | Heat pump (heat and cold) | — | X | — |
7111 ZV602930 | Heat pump (cold) | — | X | — |
7111 ZV702940 | Heat pump (heat) | — | X | — |
| SG10.CAV | — | — | Must | [95] |
7111 ZE602950 | Wallbox | — | X | — |
7111 Z8702960 | E-mobility charging station | — | X | — |
7111 ZE702970 | Charging park | — | X | — |
| SG10.CAV | — | — | Must | [447] |
7111 ZF502980 | Solar | — | X | — |
7111 ZF602990 | Wind | — | X | — |
7111 ZG003000 | Gas | — | X | — |
7111 ZG103010 | Water | — | X | — |
7111 ZG503020 | Other generation type | — | X | — |
| SG10.CAV | — | — | Must | [448] |
7111 ZF703030 | Hydrogen storage | — | X | — |
7111 ZF803040 | Pumped storage | — | X | — |
7111 ZF903050 | Battery storage | — | X | — |
7111 ZG603060 | Other storage type | — | X | — |
| SG10.CAV | — | — | Must | [446] ⊻ [448] |
7111 ZG803070 | Technical resource is covered by § 14a EnWG | — | X | — |
7111 ZG903080 | Technical resource is not covered by § 14a EnWG | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z6303090 | Information on further technical equipment | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZH703100 | Further technical equipment present | — | X | — |
7111 ZH803110 | No further technical device available | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z6203120 | Data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3803130 | Controllable resource | — | X | — |
115403140 | ID of the controllable resource | — | X | [961] |
| SG10.CCI | — | — | Must | — |
7059 Z4903150 | Control channel | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF203160 | Service description of the control channel | — | X | — |
1131 Z1403170 | On/Off | — | X | — |
1131 Z1503180 | Tiered | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB303190 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9103200 | MSB | — | X | — |
113103210 | MP-ID | — | X | — |
7110 Z3903220 | Default metering point operator | — | X | — |
7110 Z4003230 | Competitive metering point operator | — | X | — |
7110 Z4103240 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z6103250 | Product data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3803260 | Controllable resource | — | X | — |
115403270 | ID of a controllable resource | — | X | [961] |
| SG8.PIA | — | — | Must | — |
4347 503280 | Product identification | — | X | — |
714003290 | Configuration product code | — | X | — |
7143 Z1203300 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5203310 | Code of the switching time definition | — | X | — |
7059 Z5303320 | Code of the power curve definition | — | X | — |
703703330 | Code of the definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB303340 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8803350 | NB | — | X | — |
7111 Z8903360 | LF | — | X | — |
113103370 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA803380 | NB | — | X | [1P0..1] |
7037 ZA703390 | LF | — | X | [1P0..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z1803400 | Data of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1903410 | Metering location | — | X | — |
115403420 | ID of the metering location | — | X | [951] |
| SG8.RFF | — | — | Must | [668] |
1153 Z1603430 | assigned market location | — | X | — |
115403440 | ID of the market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7037 ZB303450 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9103460 | MSB | — | X | — |
113103470 | MP-ID | — | X | [622] |
7110 Z3903480 | Default metering point operator | — | X | — |
7110 Z4003490 | Competitive metering point operator | — | X | — |
7110 Z4103500 | Fallback metering point operator | — | X | — |
7110 Z1903510 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2003520 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF003530 | gMSB | — | X | — |
113103540 | MP-ID | — | X | — |
| SG10.CAV | — | — | Must | [184] |
7111 ZB403550 | MSBA | — | X | — |
113103560 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0403570 | Voltage level of the metering location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0303580 | Extra-high voltage | — | X | — |
7111 E0403590 | High voltage | — | X | — |
7111 E0503600 | Medium voltage | — | X | — |
7111 E0603610 | Low voltage | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0103620 | Scope of use | — | X | — |
7037 Z8203630 | ID of the metering location handled in the process | — | X | [2236] |
7037 Z8103640 | ID of the metering location in the location bundle | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3203650 | Operating state of the metering location | — | X | — |
7037 ZC103660 | Metering location blocked and may not be unblocked | — | X | — |
7037 ZC203670 | Metering location blocked and may be unblocked | — | X | — |
7037 ZC303680 | Metering location in regular operation | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1903690 | Required product of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1903700 | Metering location | — | X | — |
115403710 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Must | [429] |
1153 Z1803720 | Market location | — | X | — |
115403730 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 503740 | Product identification | — | X | — |
714003750 | Metering product code | — | X | [427] |
7143 Z1103760 | Product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3503770 | Description required value | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZC903780 | Second measurement required for comparative measurement | — | X | — |
7110 Z0603790 | present | — | X | — |
7110 Z0703800 | not present | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8803810 | NB | — | X | — |
7110 Z0603820 | present | — | X | — |
7110 Z0703830 | not present | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3903840 | Code of the metering time period definition | — | X | — |
7059 Z4103850 | No metering time period required for metering product | — | X | [417] |
703703860 | Code of the metering time period definition | — | X | [438] |
| SG8.SEQ | — | — | Must | — |
1229 Z0303870 | Metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1903880 | Metering location | — | X | — |
115403890 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Should | [166] ∧ [215] |
1153 Z1403900 | Smart meter gateway | — | X | — |
115403910 | Identification / number of the smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1303920 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AHZ03930 | analog household meter (three-phase current) | — | X | — |
7111 WSZ03940 | analog alternating current meter | — | X | — |
7111 LAZ03950 | Load curve meter | — | X | — |
7111 MAZ03960 | Maximum demand meter | — | X | — |
7111 MME03970 | modern metering device according to MsbG | — | X | — |
7111 EHZ03980 | electronic household meter | — | X | — |
7111 IVA03990 | Individual reconciliation (special equipment) | — | X | — |
7110 Z0104000 | EDL40 | — | X | [136] |
7110 Z0204010 | EDL21 | — | X | [136] |
7110 Z0304020 | other EHZ | — | X | [136] |
7110 Z0404030 | Standard | — | X | [346] |
7110 Z0504040 | MeDa meter | — | X | [346] |
| SG10.CAV | — | — | Must | — |
7111 Z3004050 | Device number | — | X | — |
711004060 | Device number | — | X | — |
| SG10.CAV | — | — | Must | [139] |
7111 ETZ04070 | Single tariff | — | X | — |
7111 ZTZ04080 | Two-tariff | — | X | — |
7111 NTZ04090 | Multi-tariff | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ERZ04100 | Single-direction meter | — | X | — |
7111 ZRZ04110 | Bidirectional meter | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z5804120 | Remote switching of the metering device | — | X | — |
7110 Z0604130 | present | — | X | — |
7110 Z0704140 | not present | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2804150 | Mounting type metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 BKE04160 | Plug-in technology (mounting and contacting device) | — | X | — |
7111 DPA04170 | 3-Three-point suspension | — | X | — |
7111 HUT04180 | DIN rail | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1204190 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR04200 | remotely readable meters | — | X | — |
7111 MMR04210 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2004220 | OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [78] ∧ [665] |
1153 MG04230 | Device number of the meter | — | X | [441] |
1153 Z1404240 | Smart meter gateway | — | X | — |
115404250 | Device number | — | X | — |
| SG8.RFF | — | — | Must | [78] |
1153 Z1904260 | Metering location | — | X | — |
115404270 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Must | [78] ∧ [402] ∧ [420] ∧ [651] |
1153 Z1804280 | Market location | — | X | — |
115404290 | ID of a market location | — | X | [950] |
| SG8.RFF | — | — | Must | [402] ∧ [420] |
1153 AGK04300 | Application reference number | — | X | — |
115404310 | Reference, identification | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 504320 | Product identification | — | X | — |
714004330 | OBIS code of the metering device | — | X | [323] |
7143 SRW04340 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE404350 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD904360 | Annually | — | X | — |
7111 ZE804370 | Semi-annual | — | X | — |
7111 ZE904380 | Quarterly | — | X | — |
7111 ZB704390 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1104400 | Product | — | X | — |
7037 Z3304410 | Integer and decimal places of the register | — | X | — |
| SG10.CAV | — | — | Must | — |
711004420 | Digits before the decimal point | — | X | — |
711004430 | Digits after the decimal point | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6304440 | Local identifier for control purposes | — | X | — |
703604450 | Designation of the register on the device | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0404460 | Instrument transformer data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG04470 | Device number of the meter | — | X | — |
115404480 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2504490 | Instrument transformer | — | X | — |
| SG10.CAV | — | — | Must | [2317] ⊻ [2318] |
7111 Z3004500 | Device number | — | X | — |
711004510 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 MIW04520 | Current transformer set | — | X | — |
7111 MPW04530 | Combined instrument transformer set (current and voltage) | — | X | — |
7111 MBW04540 | Block current transformer | — | X | — |
7111 MUW04550 | Voltage transformer set | — | X | — |
711004560 | Instrument transformer factor | — | X | [902] [141] |
| SG8.SEQ | — | — | Must | — |
1229 Z0504570 | Communication device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG04580 | Device number of the meter | — | X | — |
115404590 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2604600 | Communication device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004610 | Device number | — | X | — |
711004620 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 GSM04630 | GSM/GPRS/UMTS comm. dev. | — | X | — |
7111 ETH04640 | Ethernet comm. dev. LAN/WLAN | — | X | — |
7111 PLC04650 | PLC comm. device | — | X | — |
7111 PST04660 | Landline comm. dev. TAE | — | X | — |
7111 DSL04670 | DSL comm. dev. | — | X | — |
7111 LTE04680 | LTE comm. dev. | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0604690 | Data of the technical control device | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG04700 | Device number of the meter | — | X | — |
115404710 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2704720 | Technical control device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004730 | Device number | — | X | — |
711004740 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 RSU04750 | Ripple control receiver | — | X | — |
7111 TSU04760 | Tariff time switch | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1304770 | Smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7504780 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004790 | Device number | — | X | — |
711004800 | Device number | — | X | [952] |
| SG8.SEQ | — | — | Must | — |
1229 Z1404810 | Control box | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1404820 | Smart meter gateway | — | X | — |
115404830 | Identification / number of the smart meter gateway | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1804840 | Market location | — | X | — |
115404850 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7037 Z7604860 | Control box | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004870 | Device number | — | X | — |
711004880 | Device number | — | X | [952] |
| SG8.SEQ | — | — | Must | — |
1229 Z2104890 | Profile data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1804900 | Market location | — | X | — |
115404910 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7059 Z0204920 | Standard load profile | — | X | — |
7059 Z0404930 | Standard feed-in profile | — | X | — |
7037 E0104940 | synthetic method | — | X | — |
7037 Z1004950 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711104960 | Code of the standardized profile | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0804970 | Profile set data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1804980 | Market location | — | X | — |
115404990 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7059 Z0305000 | day-parameter-dependent load profile | — | X | — |
7059 Z0505010 | day-parameter-dependent feed-in profile | — | X | — |
7037 E0105020 | synthetic method | — | X | — |
7037 Z1005030 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711105040 | Code of the standardized profile | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z9905050 | Measuring station of the daily parameter (currently only the temperature is a permitted daily parameter) | — | X | — |
7059 ZA005060 | Climate zone of the daily parameter (currently is daily parameter) | — | X | — |
703705070 | ID of climate zone / temperature measuring point | — | X | — |
113105080 | Service provider | — | X | [58] |
3055 8905090 | Assigned by the trader (here grid operator) | — | X | — |
3055 29305100 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z3805110 | Reference profile data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1805120 | Market location | — | X | — |
115405130 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7059 Z0505140 | day-parameter-dependent feed-in profile | — | X | — |
| SG10.CAV | — | — | Must | — |
711105150 | Code of the reference profile | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0905160 | Customer of the LF | — | X | — |
303605170 | Name | — | X | — |
3045 Z0105180 | Structure of person names | — | X | — |
3045 Z0205190 | Structure of the company name | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1805200 | Market location | — | X | — |
115405210 | ID of the market location | — | X | [950] |
| SG12.NAD | — | — | Must | — |
3035 Z0405220 | Correspondence address of the customer of the LF | — | X | — |
303605230 | Name | — | X | — |
3045 Z0105240 | Structure of person names | — | X | — |
3045 Z0205250 | Structure of the company name | — | X | — |
304205260 | Street and house number or PO box | — | X | — |
316405270 | City | — | X | — |
325105280 | Postal code | — | — | M [268] S [166] |
320705290 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1805300 | Market location | — | X | — |
115405310 | ID of the market location | — | X | [950] |
| SG12.NAD | — | — | Must | — |
3035 Z0705320 | Customer of the MSB | — | X | — |
303605330 | Name | — | X | — |
3045 Z0105340 | Structure of person names | — | X | — |
3045 Z0205350 | Structure of the company name | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1905360 | Metering location | — | X | — |
115405370 | ID of the metering location | — | X | [951] |
| SG12.NAD | — | — | Must | — |
3035 Z0805380 | Correspondence address of the customer of the MSB | — | X | — |
303605390 | Name | — | X | — |
3045 Z0105400 | Structure of person names | — | X | — |
3045 Z0205410 | Structure of the company name | — | X | — |
304205420 | Street and house number or PO box | — | X | — |
316405430 | City | — | X | — |
325105440 | Postal code | — | — | M [268] S [166] |
320705450 | Country name, code | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0305460 | Metering location address | — | X | — |
312405470 | Additional information for identification | — | — | — |
304205480 | Street and house number or PO box | — | — | S [166] M [212] |
316405490 | City | — | X | — |
325105500 | Postal code | — | X | — |
320705510 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1905520 | Metering location | — | X | — |
115405530 | ID of a metering location | — | X | [951] |
| SG12.NAD | — | — | Must | — |
3035 Z0505540 | Name and address for the meter reading card | — | X | — |
303605550 | Name | — | X | — |
3045 Z0105560 | Structure of person names | — | X | — |
3045 Z0205570 | Structure of the company name | — | X | — |
304205580 | Street and house number or PO box | — | X | — |
316405590 | City | — | X | — |
325105600 | Postal code | — | — | M [268] S [166] |
320705610 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1905620 | Metering location | — | X | — |
115405630 | ID of a metering location | — | X | [951] |
| UNT | — | — | Must | — |
007405640 | Number of segments in a message | — | X | — |
006205650 | Message reference number | — | X | — |
Conditions of this table
The free text of the 121 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [32] | If more than one SG8 (reference to the location bundle structure) is present |
| [58] | If in this CCI the DE3055 with the code 293 is present |
| [78] | If SG4 STS+7++E02 (transaction reason: move-in to creation) is not present |
| [86] | If the RFF+Z50 (dates of the market location) from this SG6 (dates of the market location) references the same SG5 LOC+Z16 (market location) as a RFF+Z18 (market location) from a SG8 SEQ+Z01 (data of the market location) in which the SG10 CCI+++ZA6 (forecast based on profiles) is present |
| [90] | If SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) present once with CAV+E14 (TLP/TEP) and once with CAV+E02 (SLP/SEP) in this SG8 |
| [95] | If in the same SG10 the CCI+Z17 (type of electricity consumption) CAV+ZE5 (e-mobility) is present |
| [103] | If SG9 QTY+265 (energy / power for day-parameter-dependent market location: estimated annual quantity total) present in this SG8 |
| [104] | If SG9 QTY+Z08 (energy / power for day-parameter-dependent market location: adjusted electrical energy according to Annex D) present in this SG8 |
| [136] | If SG10 CCI+++E13 (meter type) CAV+EHZ (electronic household meter) present in this SG8 |
| [139] | If SG10 CAV+IVA (individual reconciliation) not present in this SG8 |
| [141] | If SG10 CAV+MIW/MPW/MBW present |
| [166] | If present |
| [173] | If DE1156 (consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is not present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [174] | If DE1156 consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [175] | If the object code in RFF+Z33 (reference to the object code in the location bundle structure) in DE1154 of the same SG8 SEQ+Z58 (assignment of location to the object code of the location bundle) is present in a further SG8 SEQ+Z58 with the same sequential number |
| [176] | If DE1153 with code Z34 upstream metering location is present in the same segment |
| [177] | If DE1153 with code Z35 upstream grid location is present in the same segment |
| [178] | If the LOC+Z18 (grid location) is present |
| [179] | If the object code in RFF+Z33 (reference to the object code in the location bundle structure) in DE1154 of the same SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle) is present in a further SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle) with an identical code in DE1229 |
| [184] | If in the same SG8 SEQ+Z18 (data of the metering location) a CCI+Z01++Z82 (scope of use: ID of the metering location handled in the process) is present |
| [210] | If SG10 CCI+++ZA6 (forecast based on profiles) present in this SG8 |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [215] | If in the same SG8 (metering device data) SG10 CCI+++E13 CAV+MME (meter type: mME) is present |
| [221] | If no SG8 SEQ+Z15 (data of the tranche) references the same market location ID with the RFF+Z18 (market location) as this SG8 SEQ+Z01 (data of the market location) |
| [239] | If in the same SG10 the CCI+Z17 (type of electricity consumption) is present in the CAV+Z65 (heat/cooling) |
| [249] | Within one SG4 IDE, all DE1131 of the SG4 STS+E01 (status of the response) must contain the identical value |
| [268] | If an "X" is listed for the code in DE3207 in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| [271] | If the RFF+Z50 (dates of the market location) from this SG6 (dates of the market location) references the same SG5 LOC+Z16 (market location) as a RFF+Z18 (market location) from a SG8 SEQ+Z01 (data of the market location) in which the SG10 CCI+++Z83 (metering classification of the market location) CAV+Z53 (kME/mME) is present |
| [291] | If in the same SG8 (assignment of location to the object code of the location bundle) the RFF+Z37 is present |
| [314] | All OBIS codes in accordance with the code list of OBIS codes and media, chapter 3, that are required at the market location must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document Code list of configurations |
| [321] | If code EM is present in DE3155 in the same COM |
| [322] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [323] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3., that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document "Code list of configurations" |
| [333] | If in this RFF "reference to the location bundle structure" the code Z31 "location bundle structure" is present in DE1153 |
| [346] | If SG10 CCI+++E13 (meter type) CAV+MME (mME) present in this SG8 |
| [402] | If in the same SG8 (OBIS data of the metering device / smart meter gateway) an OBIS code of the value type "meter reading" is present in the PIA+5 |
| [412] | Only configuration product codes from the "EDI@Energy code list of configurations", chapter 4.2 Configuration products power curve definition, are permitted |
| [417] | If no metering time period is required for the required value |
| [420] | If the RFF+Z14 (smart meter gateway) is present in this SG8 |
| [425] | Metering product code from chapter 2.1 "Standard metering products of the market location" of the code list of configurations |
| [426] | Metering product code from chapter 2.2 "Standard metering products of the tranche" of the code list of configurations |
| [427] | Metering product code from chapter 2.3 "Standard metering products of the metering location" of the code list of configurations |
| [429] | If in the same SG8 SEQ+Z19/ZF4 (required metering product of the metering location) the PIA+5 DE7140 is present with a metering product from the code list of configurations chapter 2.3.1 standard metering product of the metering location with the option of assigning a metering time period |
| [438] | If code Z39 (code of the metering time period) is present in DE7059 in the same CCI |
| [440] | If code Z35 (upstream grid location) is present in DE1153 in the same RFF |
| [441] | If RFF+Z14 (reference to the smart meter gateway) is not present in the SG8+SEQ+Z03/ZF5 (metering device data) for the device number of a meter named in this RFF DE1154 |
| [442] | If code Z34 (upstream metering location) is present in DE1153 in the same RFF |
| [446] | If in the same SG8 the CCI+Z17 (type of electricity consumption) is present |
| [447] | If in the same SG8 the CCI+Z50 (type of electricity generation) is present |
| [448] | If in the same SG8 the CCI+Z56 (storage) is present |
| [450] | If code Z32 (grid location) is present in DE1153 in the same RFF |
| [451] | If code Z18 (market location) is present in DE1153 in the same RFF |
| [452] | If code Z19 (metering location) is present in DE1153 in the same RFF |
| [456] | If code Z37 (technical resource) is present in DE1153 in the same RFF |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [611] | Note: If the company NB performs the tasks of the market role LF, the MP-ID of the company NB in the market role LF is to be stated |
| [621] | Note: The MSB must be specified that is assigned to the location from the point in time named in DTM+76 (date of the planned start of supply). |
| [622] | Note: If the OBIS code is relevant for several market roles, the segment group must be repeated for each market role |
| [651] | Note: The market locations for which the OBIS named here is required must be specified |
| [665] | Note: If a meter is parameterized with a SMGW, no OBIS code numbers are stated for that meter. Only OBIS code numbers from the SMGW exist here |
| [668] | Note: This segment will be removed from the UTILMD after completion of the introduction of the location bundle structure as of 01.10.2025 |
| [699] | Note: The ID of the controllable resource via which the technical resource is controlled must be specified |
| [700] | Note: The ID of the grid location via which the technical resource is controlled must be specified |
| [902] | Format: Possible value: ≥ 0 |
| [914] | Format: Possible value: > 0 |
| [922] | Format: TR-ID |
| [930] | Format: max. 2 decimal places |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [955] | Format: Possible value: < 100 |
| [960] | Format: Grid location ID |
| [961] | Format: SR-ID |
| [2182] | Segment group must be specified exactly once per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2183] | Segment group must be specified exactly twice per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2236] | Code once per SG4 IDE+24 (transaction) |
| [2312] | If the object code "9992000001256" (grid location) is not present in DE1154 of the same RFF+Z33, the RFF+Z33 must be specified exactly once in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [2317] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MIW/MPW/MUW is present, the segment must be specified at least twice |
| [2318] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MBW (block current transformer) is present, the segment must be specified exactly once |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [1P1..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [19P1..1] | [20] If in the SG8 SEQ+Z01 (data of the market location) with the same ID in SG8 RFF+Z18 (reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) is present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of configurations chapter 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 30 ] If another SG8 SEQ+Z27 (Required metering product of the market location), which with the RFF+Z18 (reference to the ID of the market location) references the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [20P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 31 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [22P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [26P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [4 30 ] If another SG8 SEQ+Z27 (Required metering product the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 ( for active energy load curve 1/4-hourly) is present [436] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000086 :Z11 (active energy highest 1/4 hour in the month) is present |
| [21P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [22P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [23P0..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [24P0..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [27P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 31 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [23P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [24P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [38P1..1] | [419] If no other package in this SG10 in the same SG8 SEQ leads to the possibility of specifying at least one other code in this data element |
| [19P0..1] | [20] If in the SG8 SEQ+Z01 (data of the market location) with the same ID in SG8 RFF+Z18 (reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) is present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of configurations chapter 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 30 ] If another SG8 SEQ+Z27 (Required metering product of the market location), which with the RFF+Z18 (reference to the ID of the market location) references the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [20P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 31 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [26P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [4 30 ] If another SG8 SEQ+Z27 (Required metering product the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 ( for active energy load curve 1/4-hourly) is present [436] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000086 :Z11 (active energy highest 1/4 hour in the month) is present |
| [21P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [25P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 30 ] If another SG8 SEQ+Z27 (Required metering product the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 ( for active energy load curve 1/4-hourly) is present |
| [29P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [405] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and cumulative in the PIA+5 present [410] If a SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and 1/4 hour in the PIA+5 present |
| [30P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [405] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and cumulative in the PIA+5 present [411] If no SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and 1/4 hour in the PIA+5 present |
| [32P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [409] If no SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [36P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [406] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and highest 1/4 hour in the month in the PIA+5 present |
| [31P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [408] If a SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [32P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [409] If no SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [33P0..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [408] If a SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [34P0..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [409] If no SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [37P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [405] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and cumulative in the PIA+5 present [411] If no SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and 1/4 hour in the PIA+5 present |
| [33P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [408] If a SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [34P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [409] If no SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [29P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [405] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and cumulative in the PIA+5 present [410] If a SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and 1/4 hour in the PIA+5 present |
| [30P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [405] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and cumulative in the PIA+5 present [411] If no SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and 1/4 hour in the PIA+5 present |
| [36P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [406] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and highest 1/4 hour in the month in the PIA+5 present |
| [31P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [396] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and 1/4 hour in the PIA+5 present [408] If a SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and cumulative in the PIA+5 present |
| [28P0..1] | [407] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for reactive energy in the PIA+5 present |
| [35P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [405] If in the same SG8 SEQ+Z02/ZA1/ZA2 (OBIS data of the market location) a OBIS code for active energy and cumulative in the PIA+5 present [410] If a SG8 SEQ+Z02 (OBIS data of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location as the RFF+Z18 (Reference to the ID of the market location) in this SG8, with a OBIS code for active energy and 1/4 hour in the PIA+5 present |
Example message
UNA:+.? '
UNB+UNOC:3+9904446000007:500+9900321000005:500+{{date}}:{{time}}+M40MMDV8'
UNH+UNHM3WASW1U+UTILMD:D:11A:UN:S2.1'
BGM+E01+BGMM3I58NYT'
DTM+137:202506051200?+00:303'
NAD+MS+9904446000007::293'
NAD+MR+9900321000005::293'
IDE+24+123456'
DTM+76:202506302200?+00:303'
STS+7++E02'
STS+E01++E15:S_0063'
LOC+Z16+50074561188'
LOC+Z17+DE0032106765712000000000000000037'
RFF+Z13:55169'
RFF+TN:ABC123456'
RFF+Z50:50074561188'
DTM+752:0101:106'
SEQ+Z78'
RFF+Z31:9992000000026'
SEQ+Z58'
RFF+Z18:50074561188'
RFF+Z33:9992000001016'
SEQ+Z58'
RFF+Z19:DE0032106765712000000000000000037'
RFF+Z33:9992000001032'
SEQ+Z01'
RFF+Z18:50074561188'
QTY+31:2000:KWH'
CCI+Z30++Z07'
CCI+++ZB3'
CAV+Z90:4045399000077'
CAV+Z91:4045458000017::Z39:Z20'
CCI+++E03'
CAV+E06'
CCI+++Z83'
CAV+Z53'
CCI+6++ZA8'
CCI+++ZA6'
CAV+E02'
CCI+ZA2++ZE9'
SEQ+Z27'
RFF+Z18:50074561188'
PIA+5+9991000000044:Z11'
CCI+Z41'
CCI+++ZA8'
CAV+ZE1'
CCI+++ZA7'
CAV+ZE1'
SEQ+Z02'
RFF+Z18:50074561188'
PIA+5+1-1?:1.9.0:SRW'
CCI+++ZE4'
CAV+ZD9'
CCI+++ZA8'
CAV+ZE1'
CCI+++ZA7'
CAV+ZE1'
SEQ+Z18'
RFF+Z19:DE0032106765712000000000000000037'
RFF+Z16:50074561188'
CCI+++ZB3'
CAV+Z91:4045458000017::Z39:Z20'
CAV+ZF0:9904446000007'
CAV+ZB4:9904446000007'
CCI+++E04'
CAV+E06'
CCI+Z01++Z82'
CCI+Z32++ZC3'
SEQ+Z19'
RFF+Z19:DE0032106765712000000000000000037'
RFF+Z18:50074561188'
PIA+5+9991000000151:Z11'
CCI+Z35'
CAV+ZC9:::Z07'
CAV+Z88:::Z07'
CCI+Z41'
SEQ+Z21'
RFF+Z18:50074561188'
CCI+Z02++E01'
CAV+H0'
NAD+Z07+++Mustermann:Max::::Z01'
RFF+Z19:DE0032106765712000000000000000037'
NAD+Z08+++Mustermann:Max::::Z01+Straße::1+Ort++12345+DE'
NAD+Z03++Mustermann:Max++Straße::1+Ort++12345+DE'
RFF+Z19:DE0032106765712000000000000000037'
NAD+Z05+++Mustermann:Max::::Z01+Straße::1+Ort++12345+DE'
RFF+Z19:DE0032106765712000000000000000037'
UNT+86+UNHM3WASW1U'
UNZ+1+M40MMDV8'[1 item
{6 fields
"data": {3 fields
"stammdaten": {6 fields
"MARKTLOKATION": [1 item
{10 fields
"marktlokationsTyp": [1 item
{1 field
"marktrollen": [3 items
{6 fields
{6 fields
{8 fields
"zaehlwerke": [1 item
{5 fields
"verwendungszwecke": [2 items
{2 fields
{2 fields
"zaehlzeiten": {1 field
"MESSLOKATION": [1 item
{12 fields
"messadresse": {6 fields
"zusatzInformation": {2 fields
"zaehlwerke": [1 item
{4 fields
"zaehlzeiten": {1 field
"ablesekartenempfaenger": {7 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {5 fields
"marktrollen": [3 items
{8 fields
{6 fields
{6 fields
"LOKATIONSBUENDEL": [1 item
{5 fields
"zuordnungObjectcode": [2 items
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
"NETZNUTZUNGSVERTRAG": [1 item
{6 fields
"MESSSTELLENBETRIEBSVERTRAG": [1 item
{9 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"vertragskonditionen": {1 field
"geplanteTurnusablesung": {1 field
"korrespondenzpartner": {6 fields
"partneradresse": {5 fields
"BILANZIERUNG": [1 item
{9 fields
"lastprofile": [1 item
{5 fields
"jahresverbrauchsprognose": {2 fields
"detailsPrognosegrundlage": [1 item
"transaktionsdaten": {15 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | NB | End of metering point operation | WiM electricity part 1 | Electricity | Step 4 |
| MSB | GMSB | End of metering point operation | WiM electricity part 1 | Electricity | Step 4 |
| MSB | MSBA | End of metering point operation | WiM electricity part 1 | Electricity | Step 4 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Confirmation of commitment request |
| AHB | UTILMD AHB electricity |
| Decision tree | E_0240 |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 1 | End of metering point operation | MSB (corresponds to gMSB on the object metering location) → NB | Response to commitment request |
One entry from format version 202610
The check identifiers table of format version 202604 does not carry this entry: decision tree. It comes from version 202610. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202604.
Transaction and responses
Role of this check identifier: response — confirmation. Basis: the transaction data carry antwortstatus and antwortstatusCodeliste; the title or the action of the Prüfi table begins with “response”; the title names a polarity (confirmation).
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 55168 | Commitment request / demand | UTILMD | from the step sequence |
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfragereferenznummer | SG4.IDE+24.SG6.RFF+TN | vorgangsnummer |
For RFF+TN, the time slice field description gives »reference transaction number (from request message)« — the target is the vorgangsnummer in segment SG4.IDE+24 of the request. Measured: 55168 lists vorgangsnummer in SG4.IDE+24.
Response codes
Decision trees: S_0063 · E_0240.
The Prüfi table names one further tree across all rows of this check identifier. They tie it to a process, not to a row of its handbook — their codes are therefore only on the respective tree page. For S_0063 there is no decision tree in version 202604; its response codes are therefore not given here.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 797 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type utilmd. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.