Check identifier 55634 — Response message/request for data of MaLo
Check identifier 55634 · EDIFACT message type UTILMD · format version 202604
Data structure
| Structure (BO4E) | Description | Format | 55634 | Condition |
|---|---|---|---|---|
| stammdaten | — | object | May | — |
| BILANZIERUNG [ ] | — | object[] | May | — |
| abwicklungsmodell 00010 | Processing model | Enum Abwicklungsmodell | Must | — |
MODELL_1_BILANZIERUNG_AN_MARKTLOKATION | — | — | Must | — |
MODELL_2_BILANZIERUNG_IM_BILANZIERUNGSGEBIET | — | — | Must | — |
| datenqualitaet 00020 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| detailsPrognosegrundlage 00030 | Forecast basis - If a day-parameter-dependent load profile with joint metering has to be specified, this is possible by repeating the CAV segment twice, stating the codes E02 and E14. | array | Must | — |
| prognosegrundlage 00040 | Forecast basis | Enum Prognosegrundlage | Must | — |
WERTE | — | — | Must | — |
PROFILE | — | — | Must | — |
| gueltigkeitszeitraum | — | object | May | — |
| zeitraumId 00050 | zeitraumId | integer | Must | — |
| jahresverbrauchsprognose | — | object | May | — |
| einheit 00060 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 00070 | Value | number (float) | X | — |
| lastprofile [ ] | — | object[] | May | — |
| bezeichnung 00080 | Designation of the profile | string | Must | — |
| einspeisung 00090 | Feed-in indicator | boolean | Must | — |
| profilart 00100 | Profile category | Enum Profilart | Must | — |
ART_STANDARDLASTPROFIL | — | — | Must | — |
ART_TAGESPARAMETERABHAENGIGES_LASTPROFIL | — | — | Must | — |
ART_LASTPROFIL | — | — | Must | — |
| referenzprofilbezeichnung 00110 | Designation of the reference profile | string | Must | — |
| verfahren 00120 | Profiling method | Enum Profilverfahren | Must | — |
SYNTHETISCH | — | — | Must | — |
ANALYTISCH | — | — | Must | — |
| temperaturarbeit | — | object | May | — |
| einheit 00130 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | Must | — |
W | — | — | Must | — |
WH | — | — | Must | — |
KW | — | — | Must | — |
KWH | — | — | Must | — |
KVARH | — | — | Must | — |
MW | — | — | Must | — |
MWH | — | — | Must | — |
STUECK | — | — | Must | — |
KUBIKMETER | — | — | Must | — |
STUNDE | — | — | Must | — |
TAG | — | — | Must | — |
MONAT | — | — | Must | — |
JAHR | — | — | Must | — |
PROZENT | — | — | Must | — |
ANZAHL | — | — | Must | — |
VAR | — | — | Must | — |
KVAR | — | — | Must | — |
VARH | — | — | Must | — |
KWHK | — | — | Must | — |
Z16 | — | — | Must | — |
KWT | — | — | Must | — |
WATT_PRO_QUADRATMETER | — | — | Must | — |
METER_PRO_SEKUNDE | — | — | Must | — |
| wert 00140 | Value | number (float) | Must | — |
| MARKTLOKATION [ ] | — | object[] | May | — |
| datenqualitaet 00150 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| marktlokationsId 00160 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| messtechnischeEinordnung 00170 | Metering classification from the UTILMD (IMS, KME_MME, KEINE_MESSUNG) | Enum MesstechnischeEinordnung | Must | — |
IMS | — | — | Must | — |
KME_MME | — | — | Must | — |
KEINE_MESSUNG | — | — | Must | — |
| netzebene 00180 | Grid level at which the energy is drawn. For electricity, the voltage level of the supply; for gas, the pressure level. Example electricity: low voltage Example gas: low pressure. | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| umspannung 00190 | Grid level | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| eigentuemer | — | object | May | — |
| anrede 00200 | The form of address for the GePa, e.g. Mr. | string | Must | — |
| gewerbekennzeichnung 00210 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | Must | — |
| name1 00220 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | Must | — |
| name2 00230 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | Must | — |
| name3 00240 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | Must | — |
| name4 00250 | name4 | string | Must | — |
| partneradresse | — | object | May | — |
| hausnummer 00260 | House number and supplement | string | Must | — |
| landescode 00270 | Country code | Enum Landescode | Must | — |
AC | — | — | Must | — |
AD | — | — | Must | — |
AE | — | — | Must | — |
AF | — | — | Must | — |
AG | — | — | Must | — |
AI | — | — | Must | — |
AL | — | — | Must | — |
AM | — | — | Must | — |
AN | — | — | Must | — |
AO | — | — | Must | — |
AQ | — | — | Must | — |
AR | — | — | Must | — |
AS | — | — | Must | — |
AT | — | — | Must | — |
AU | — | — | Must | — |
AW | — | — | Must | — |
AX | — | — | Must | — |
AZ | — | — | Must | — |
BA | — | — | Must | — |
BB | — | — | Must | — |
BD | — | — | Must | — |
BE | — | — | Must | — |
BF | — | — | Must | — |
BG | — | — | Must | — |
BH | — | — | Must | — |
BI | — | — | Must | — |
BJ | — | — | Must | — |
BL | — | — | Must | — |
BM | — | — | Must | — |
BN | — | — | Must | — |
BO | — | — | Must | — |
BQ | — | — | Must | — |
BR | — | — | Must | — |
BS | — | — | Must | — |
BT | — | — | Must | — |
BU | — | — | Must | — |
BV | — | — | Must | — |
BW | — | — | Must | — |
BY | — | — | Must | — |
BZ | — | — | Must | — |
CA | — | — | Must | — |
CC | — | — | Must | — |
CD | — | — | Must | — |
CF | — | — | Must | — |
CG | — | — | Must | — |
CH | — | — | Must | — |
CI | — | — | Must | — |
CK | — | — | Must | — |
CL | — | — | Must | — |
CM | — | — | Must | — |
CN | — | — | Must | — |
CO | — | — | Must | — |
CP | — | — | Must | — |
CR | — | — | Must | — |
CS | — | — | Must | — |
CU | — | — | Must | — |
CV | — | — | Must | — |
CW | — | — | Must | — |
CX | — | — | Must | — |
CY | — | — | Must | — |
CZ | — | — | Must | — |
DE | — | — | Must | — |
DG | — | — | Must | — |
DJ | — | — | Must | — |
DK | — | — | Must | — |
DM | — | — | Must | — |
DO | — | — | Must | — |
DZ | — | — | Must | — |
EA | — | — | Must | — |
EC | — | — | Must | — |
EE | — | — | Must | — |
EG | — | — | Must | — |
EH | — | — | Must | — |
ER | — | — | Must | — |
ES | — | — | Must | — |
ET | — | — | Must | — |
EU | — | — | Must | — |
FI | — | — | Must | — |
FJ | — | — | Must | — |
FK | — | — | Must | — |
FM | — | — | Must | — |
FO | — | — | Must | — |
FR | — | — | Must | — |
FX | — | — | Must | — |
GA | — | — | Must | — |
GB | — | — | Must | — |
GD | — | — | Must | — |
GE | — | — | Must | — |
GF | — | — | Must | — |
GG | — | — | Must | — |
GH | — | — | Must | — |
GI | — | — | Must | — |
GL | — | — | Must | — |
GM | — | — | Must | — |
GN | — | — | Must | — |
GP | — | — | Must | — |
GQ | — | — | Must | — |
GR | — | — | Must | — |
GS | — | — | Must | — |
GT | — | — | Must | — |
GU | — | — | Must | — |
GW | — | — | Must | — |
GY | — | — | Must | — |
HK | — | — | Must | — |
HM | — | — | Must | — |
HN | — | — | Must | — |
HR | — | — | Must | — |
HT | — | — | Must | — |
HU | — | — | Must | — |
IC | — | — | Must | — |
ID | — | — | Must | — |
IE | — | — | Must | — |
IL | — | — | Must | — |
IM | — | — | Must | — |
IN | — | — | Must | — |
IO | — | — | Must | — |
IQ | — | — | Must | — |
IR | — | — | Must | — |
IS | — | — | Must | — |
IT | — | — | Must | — |
JE | — | — | Must | — |
JM | — | — | Must | — |
JO | — | — | Must | — |
JP | — | — | Must | — |
KE | — | — | Must | — |
KG | — | — | Must | — |
KH | — | — | Must | — |
KI | — | — | Must | — |
KM | — | — | Must | — |
KN | — | — | Must | — |
KP | — | — | Must | — |
KR | — | — | Must | — |
KW | — | — | Must | — |
KY | — | — | Must | — |
KZ | — | — | Must | — |
LA | — | — | Must | — |
LB | — | — | Must | — |
LC | — | — | Must | — |
LI | — | — | Must | — |
LK | — | — | Must | — |
LR | — | — | Must | — |
LS | — | — | Must | — |
LT | — | — | Must | — |
LU | — | — | Must | — |
LV | — | — | Must | — |
LY | — | — | Must | — |
MA | — | — | Must | — |
MC | — | — | Must | — |
MD | — | — | Must | — |
ME | — | — | Must | — |
MF | — | — | Must | — |
MG | — | — | Must | — |
MH | — | — | Must | — |
MK | — | — | Must | — |
ML | — | — | Must | — |
MM | — | — | Must | — |
MN | — | — | Must | — |
MO | — | — | Must | — |
MP | — | — | Must | — |
MQ | — | — | Must | — |
MR | — | — | Must | — |
MS | — | — | Must | — |
MT | — | — | Must | — |
MU | — | — | Must | — |
MV | — | — | Must | — |
MW | — | — | Must | — |
MX | — | — | Must | — |
MY | — | — | Must | — |
MZ | — | — | Must | — |
NA | — | — | Must | — |
NC | — | — | Must | — |
NE | — | — | Must | — |
NF | — | — | Must | — |
NG | — | — | Must | — |
NI | — | — | Must | — |
NL | — | — | Must | — |
NO | — | — | Must | — |
NP | — | — | Must | — |
NR | — | — | Must | — |
NT | — | — | Must | — |
NU | — | — | Must | — |
NZ | — | — | Must | — |
OM | — | — | Must | — |
PA | — | — | Must | — |
PE | — | — | Must | — |
PF | — | — | Must | — |
PG | — | — | Must | — |
PH | — | — | Must | — |
PK | — | — | Must | — |
PL | — | — | Must | — |
PM | — | — | Must | — |
PN | — | — | Must | — |
PR | — | — | Must | — |
PS | — | — | Must | — |
PT | — | — | Must | — |
PW | — | — | Must | — |
PY | — | — | Must | — |
QA | — | — | Must | — |
RE | — | — | Must | — |
RO | — | — | Must | — |
RS | — | — | Must | — |
RU | — | — | Must | — |
RW | — | — | Must | — |
SA | — | — | Must | — |
SB | — | — | Must | — |
SC | — | — | Must | — |
SD | — | — | Must | — |
SE | — | — | Must | — |
SF | — | — | Must | — |
SG | — | — | Must | — |
SH | — | — | Must | — |
SI | — | — | Must | — |
SJ | — | — | Must | — |
SK | — | — | Must | — |
SL | — | — | Must | — |
SM | — | — | Must | — |
SN | — | — | Must | — |
SO | — | — | Must | — |
SR | — | — | Must | — |
SS | — | — | Must | — |
ST | — | — | Must | — |
SU | — | — | Must | — |
SV | — | — | Must | — |
SX | — | — | Must | — |
SY | — | — | Must | — |
SZ | — | — | Must | — |
TA | — | — | Must | — |
TC | — | — | Must | — |
TD | — | — | Must | — |
TF | — | — | Must | — |
TG | — | — | Must | — |
TJ | — | — | Must | — |
TK | — | — | Must | — |
TL | — | — | Must | — |
TM | — | — | Must | — |
TN | — | — | Must | — |
TO | — | — | Must | — |
TP | — | — | Must | — |
TR | — | — | Must | — |
TT | — | — | Must | — |
TV | — | — | Must | — |
TW | — | — | Must | — |
TZ | — | — | Must | — |
UA | — | — | Must | — |
UG | — | — | Must | — |
UK | — | — | Must | — |
UM | — | — | Must | — |
US | — | — | Must | — |
UY | — | — | Must | — |
UZ | — | — | Must | — |
VA | — | — | Must | — |
VC | — | — | Must | — |
VE | — | — | Must | — |
VG | — | — | Must | — |
VI | — | — | Must | — |
VN | — | — | Must | — |
VU | — | — | Must | — |
WF | — | — | Must | — |
WS | — | — | Must | — |
XK | — | — | Must | — |
YE | — | — | Must | — |
YT | — | — | Must | — |
YU | — | — | Must | — |
ZA | — | — | Must | — |
ZM | — | — | Must | — |
ZR | — | — | Must | — |
ZW | — | — | Must | — |
| ort 00280 | City | string | Must | — |
| ortsteil 00290 | District | string | Must | — |
| postfach 00300 | PO box | string | Must | — |
| postleitzahl 00310 | Postal code | string | Must | — |
| strasse 00320 | Street | string | Must | — |
| energieherkunft [ ] | — | object[] | May | — |
| erzeugungsart 00330 | Type of generation | Enum Erzeugungsart | Must | — |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| gueltigkeitszeitraum | — | object | May | — |
| zeitraumId 00340 | zeitraumId | integer | X | — |
| hausverwalter | — | object | May | — |
| anrede 00350 | The form of address for the GePa, e.g. Mr. | string | Must | — |
| gewerbekennzeichnung 00360 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | Must | — |
| name1 00370 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | Must | — |
| name2 00380 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | Must | — |
| name3 00390 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | Must | — |
| name4 00400 | name4 | string | Must | — |
| partneradresse | — | object | May | — |
| hausnummer 00410 | House number and supplement | string | Must | — |
| landescode 00420 | Country code | Enum Landescode | Must | — |
AC | — | — | Must | — |
AD | — | — | Must | — |
AE | — | — | Must | — |
AF | — | — | Must | — |
AG | — | — | Must | — |
AI | — | — | Must | — |
AL | — | — | Must | — |
AM | — | — | Must | — |
AN | — | — | Must | — |
AO | — | — | Must | — |
AQ | — | — | Must | — |
AR | — | — | Must | — |
AS | — | — | Must | — |
AT | — | — | Must | — |
AU | — | — | Must | — |
AW | — | — | Must | — |
AX | — | — | Must | — |
AZ | — | — | Must | — |
BA | — | — | Must | — |
BB | — | — | Must | — |
BD | — | — | Must | — |
BE | — | — | Must | — |
BF | — | — | Must | — |
BG | — | — | Must | — |
BH | — | — | Must | — |
BI | — | — | Must | — |
BJ | — | — | Must | — |
BL | — | — | Must | — |
BM | — | — | Must | — |
BN | — | — | Must | — |
BO | — | — | Must | — |
BQ | — | — | Must | — |
BR | — | — | Must | — |
BS | — | — | Must | — |
BT | — | — | Must | — |
BU | — | — | Must | — |
BV | — | — | Must | — |
BW | — | — | Must | — |
BY | — | — | Must | — |
BZ | — | — | Must | — |
CA | — | — | Must | — |
CC | — | — | Must | — |
CD | — | — | Must | — |
CF | — | — | Must | — |
CG | — | — | Must | — |
CH | — | — | Must | — |
CI | — | — | Must | — |
CK | — | — | Must | — |
CL | — | — | Must | — |
CM | — | — | Must | — |
CN | — | — | Must | — |
CO | — | — | Must | — |
CP | — | — | Must | — |
CR | — | — | Must | — |
CS | — | — | Must | — |
CU | — | — | Must | — |
CV | — | — | Must | — |
CW | — | — | Must | — |
CX | — | — | Must | — |
CY | — | — | Must | — |
CZ | — | — | Must | — |
DE | — | — | Must | — |
DG | — | — | Must | — |
DJ | — | — | Must | — |
DK | — | — | Must | — |
DM | — | — | Must | — |
DO | — | — | Must | — |
DZ | — | — | Must | — |
EA | — | — | Must | — |
EC | — | — | Must | — |
EE | — | — | Must | — |
EG | — | — | Must | — |
EH | — | — | Must | — |
ER | — | — | Must | — |
ES | — | — | Must | — |
ET | — | — | Must | — |
EU | — | — | Must | — |
FI | — | — | Must | — |
FJ | — | — | Must | — |
FK | — | — | Must | — |
FM | — | — | Must | — |
FO | — | — | Must | — |
FR | — | — | Must | — |
FX | — | — | Must | — |
GA | — | — | Must | — |
GB | — | — | Must | — |
GD | — | — | Must | — |
GE | — | — | Must | — |
GF | — | — | Must | — |
GG | — | — | Must | — |
GH | — | — | Must | — |
GI | — | — | Must | — |
GL | — | — | Must | — |
GM | — | — | Must | — |
GN | — | — | Must | — |
GP | — | — | Must | — |
GQ | — | — | Must | — |
GR | — | — | Must | — |
GS | — | — | Must | — |
GT | — | — | Must | — |
GU | — | — | Must | — |
GW | — | — | Must | — |
GY | — | — | Must | — |
HK | — | — | Must | — |
HM | — | — | Must | — |
HN | — | — | Must | — |
HR | — | — | Must | — |
HT | — | — | Must | — |
HU | — | — | Must | — |
IC | — | — | Must | — |
ID | — | — | Must | — |
IE | — | — | Must | — |
IL | — | — | Must | — |
IM | — | — | Must | — |
IN | — | — | Must | — |
IO | — | — | Must | — |
IQ | — | — | Must | — |
IR | — | — | Must | — |
IS | — | — | Must | — |
IT | — | — | Must | — |
JE | — | — | Must | — |
JM | — | — | Must | — |
JO | — | — | Must | — |
JP | — | — | Must | — |
KE | — | — | Must | — |
KG | — | — | Must | — |
KH | — | — | Must | — |
KI | — | — | Must | — |
KM | — | — | Must | — |
KN | — | — | Must | — |
KP | — | — | Must | — |
KR | — | — | Must | — |
KW | — | — | Must | — |
KY | — | — | Must | — |
KZ | — | — | Must | — |
LA | — | — | Must | — |
LB | — | — | Must | — |
LC | — | — | Must | — |
LI | — | — | Must | — |
LK | — | — | Must | — |
LR | — | — | Must | — |
LS | — | — | Must | — |
LT | — | — | Must | — |
LU | — | — | Must | — |
LV | — | — | Must | — |
LY | — | — | Must | — |
MA | — | — | Must | — |
MC | — | — | Must | — |
MD | — | — | Must | — |
ME | — | — | Must | — |
MF | — | — | Must | — |
MG | — | — | Must | — |
MH | — | — | Must | — |
MK | — | — | Must | — |
ML | — | — | Must | — |
MM | — | — | Must | — |
MN | — | — | Must | — |
MO | — | — | Must | — |
MP | — | — | Must | — |
MQ | — | — | Must | — |
MR | — | — | Must | — |
MS | — | — | Must | — |
MT | — | — | Must | — |
MU | — | — | Must | — |
MV | — | — | Must | — |
MW | — | — | Must | — |
MX | — | — | Must | — |
MY | — | — | Must | — |
MZ | — | — | Must | — |
NA | — | — | Must | — |
NC | — | — | Must | — |
NE | — | — | Must | — |
NF | — | — | Must | — |
NG | — | — | Must | — |
NI | — | — | Must | — |
NL | — | — | Must | — |
NO | — | — | Must | — |
NP | — | — | Must | — |
NR | — | — | Must | — |
NT | — | — | Must | — |
NU | — | — | Must | — |
NZ | — | — | Must | — |
OM | — | — | Must | — |
PA | — | — | Must | — |
PE | — | — | Must | — |
PF | — | — | Must | — |
PG | — | — | Must | — |
PH | — | — | Must | — |
PK | — | — | Must | — |
PL | — | — | Must | — |
PM | — | — | Must | — |
PN | — | — | Must | — |
PR | — | — | Must | — |
PS | — | — | Must | — |
PT | — | — | Must | — |
PW | — | — | Must | — |
PY | — | — | Must | — |
QA | — | — | Must | — |
RE | — | — | Must | — |
RO | — | — | Must | — |
RS | — | — | Must | — |
RU | — | — | Must | — |
RW | — | — | Must | — |
SA | — | — | Must | — |
SB | — | — | Must | — |
SC | — | — | Must | — |
SD | — | — | Must | — |
SE | — | — | Must | — |
SF | — | — | Must | — |
SG | — | — | Must | — |
SH | — | — | Must | — |
SI | — | — | Must | — |
SJ | — | — | Must | — |
SK | — | — | Must | — |
SL | — | — | Must | — |
SM | — | — | Must | — |
SN | — | — | Must | — |
SO | — | — | Must | — |
SR | — | — | Must | — |
SS | — | — | Must | — |
ST | — | — | Must | — |
SU | — | — | Must | — |
SV | — | — | Must | — |
SX | — | — | Must | — |
SY | — | — | Must | — |
SZ | — | — | Must | — |
TA | — | — | Must | — |
TC | — | — | Must | — |
TD | — | — | Must | — |
TF | — | — | Must | — |
TG | — | — | Must | — |
TJ | — | — | Must | — |
TK | — | — | Must | — |
TL | — | — | Must | — |
TM | — | — | Must | — |
TN | — | — | Must | — |
TO | — | — | Must | — |
TP | — | — | Must | — |
TR | — | — | Must | — |
TT | — | — | Must | — |
TV | — | — | Must | — |
TW | — | — | Must | — |
TZ | — | — | Must | — |
UA | — | — | Must | — |
UG | — | — | Must | — |
UK | — | — | Must | — |
UM | — | — | Must | — |
US | — | — | Must | — |
UY | — | — | Must | — |
UZ | — | — | Must | — |
VA | — | — | Must | — |
VC | — | — | Must | — |
VE | — | — | Must | — |
VG | — | — | Must | — |
VI | — | — | Must | — |
VN | — | — | Must | — |
VU | — | — | Must | — |
WF | — | — | Must | — |
WS | — | — | Must | — |
XK | — | — | Must | — |
YE | — | — | Must | — |
YT | — | — | Must | — |
YU | — | — | Must | — |
ZA | — | — | Must | — |
ZM | — | — | Must | — |
ZR | — | — | Must | — |
ZW | — | — | Must | — |
| ort 00430 | City | string | Must | — |
| ortsteil 00440 | District | string | Must | — |
| postfach 00450 | PO box | string | Must | — |
| postleitzahl 00460 | Postal code | string | Must | — |
| strasse 00470 | Street | string | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00480 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00490 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00500 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00510 | weiterverpflichtet | boolean | X | — |
| NETZNUTZUNGSVERTRAG [ ] | — | object[] | May | — |
| datenqualitaet 00520 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| gueltigkeitszeitraum | — | object | May | — |
| zeitraumId 00530 | zeitraumId | integer | X | — |
| korrespondenzpartner | — | object | May | — |
| anrede 00540 | The form of address for the GePa, e.g. Mr. | string | Must | — |
| name1 00550 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | Must | — |
| name2 00560 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | Must | — |
| name3 00570 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | Must | — |
| name4 00580 | name4 | string | Must | — |
| partneradresse | — | object | May | — |
| hausnummer 00590 | House number and supplement | string | Must | — |
| landescode 00600 | Country code | Enum Landescode | Must | — |
AC | — | — | Must | — |
AD | — | — | Must | — |
AE | — | — | Must | — |
AF | — | — | Must | — |
AG | — | — | Must | — |
AI | — | — | Must | — |
AL | — | — | Must | — |
AM | — | — | Must | — |
AN | — | — | Must | — |
AO | — | — | Must | — |
AQ | — | — | Must | — |
AR | — | — | Must | — |
AS | — | — | Must | — |
AT | — | — | Must | — |
AU | — | — | Must | — |
AW | — | — | Must | — |
AX | — | — | Must | — |
AZ | — | — | Must | — |
BA | — | — | Must | — |
BB | — | — | Must | — |
BD | — | — | Must | — |
BE | — | — | Must | — |
BF | — | — | Must | — |
BG | — | — | Must | — |
BH | — | — | Must | — |
BI | — | — | Must | — |
BJ | — | — | Must | — |
BL | — | — | Must | — |
BM | — | — | Must | — |
BN | — | — | Must | — |
BO | — | — | Must | — |
BQ | — | — | Must | — |
BR | — | — | Must | — |
BS | — | — | Must | — |
BT | — | — | Must | — |
BU | — | — | Must | — |
BV | — | — | Must | — |
BW | — | — | Must | — |
BY | — | — | Must | — |
BZ | — | — | Must | — |
CA | — | — | Must | — |
CC | — | — | Must | — |
CD | — | — | Must | — |
CF | — | — | Must | — |
CG | — | — | Must | — |
CH | — | — | Must | — |
CI | — | — | Must | — |
CK | — | — | Must | — |
CL | — | — | Must | — |
CM | — | — | Must | — |
CN | — | — | Must | — |
CO | — | — | Must | — |
CP | — | — | Must | — |
CR | — | — | Must | — |
CS | — | — | Must | — |
CU | — | — | Must | — |
CV | — | — | Must | — |
CW | — | — | Must | — |
CX | — | — | Must | — |
CY | — | — | Must | — |
CZ | — | — | Must | — |
DE | — | — | Must | — |
DG | — | — | Must | — |
DJ | — | — | Must | — |
DK | — | — | Must | — |
DM | — | — | Must | — |
DO | — | — | Must | — |
DZ | — | — | Must | — |
EA | — | — | Must | — |
EC | — | — | Must | — |
EE | — | — | Must | — |
EG | — | — | Must | — |
EH | — | — | Must | — |
ER | — | — | Must | — |
ES | — | — | Must | — |
ET | — | — | Must | — |
EU | — | — | Must | — |
FI | — | — | Must | — |
FJ | — | — | Must | — |
FK | — | — | Must | — |
FM | — | — | Must | — |
FO | — | — | Must | — |
FR | — | — | Must | — |
FX | — | — | Must | — |
GA | — | — | Must | — |
GB | — | — | Must | — |
GD | — | — | Must | — |
GE | — | — | Must | — |
GF | — | — | Must | — |
GG | — | — | Must | — |
GH | — | — | Must | — |
GI | — | — | Must | — |
GL | — | — | Must | — |
GM | — | — | Must | — |
GN | — | — | Must | — |
GP | — | — | Must | — |
GQ | — | — | Must | — |
GR | — | — | Must | — |
GS | — | — | Must | — |
GT | — | — | Must | — |
GU | — | — | Must | — |
GW | — | — | Must | — |
GY | — | — | Must | — |
HK | — | — | Must | — |
HM | — | — | Must | — |
HN | — | — | Must | — |
HR | — | — | Must | — |
HT | — | — | Must | — |
HU | — | — | Must | — |
IC | — | — | Must | — |
ID | — | — | Must | — |
IE | — | — | Must | — |
IL | — | — | Must | — |
IM | — | — | Must | — |
IN | — | — | Must | — |
IO | — | — | Must | — |
IQ | — | — | Must | — |
IR | — | — | Must | — |
IS | — | — | Must | — |
IT | — | — | Must | — |
JE | — | — | Must | — |
JM | — | — | Must | — |
JO | — | — | Must | — |
JP | — | — | Must | — |
KE | — | — | Must | — |
KG | — | — | Must | — |
KH | — | — | Must | — |
KI | — | — | Must | — |
KM | — | — | Must | — |
KN | — | — | Must | — |
KP | — | — | Must | — |
KR | — | — | Must | — |
KW | — | — | Must | — |
KY | — | — | Must | — |
KZ | — | — | Must | — |
LA | — | — | Must | — |
LB | — | — | Must | — |
LC | — | — | Must | — |
LI | — | — | Must | — |
LK | — | — | Must | — |
LR | — | — | Must | — |
LS | — | — | Must | — |
LT | — | — | Must | — |
LU | — | — | Must | — |
LV | — | — | Must | — |
LY | — | — | Must | — |
MA | — | — | Must | — |
MC | — | — | Must | — |
MD | — | — | Must | — |
ME | — | — | Must | — |
MF | — | — | Must | — |
MG | — | — | Must | — |
MH | — | — | Must | — |
MK | — | — | Must | — |
ML | — | — | Must | — |
MM | — | — | Must | — |
MN | — | — | Must | — |
MO | — | — | Must | — |
MP | — | — | Must | — |
MQ | — | — | Must | — |
MR | — | — | Must | — |
MS | — | — | Must | — |
MT | — | — | Must | — |
MU | — | — | Must | — |
MV | — | — | Must | — |
MW | — | — | Must | — |
MX | — | — | Must | — |
MY | — | — | Must | — |
MZ | — | — | Must | — |
NA | — | — | Must | — |
NC | — | — | Must | — |
NE | — | — | Must | — |
NF | — | — | Must | — |
NG | — | — | Must | — |
NI | — | — | Must | — |
NL | — | — | Must | — |
NO | — | — | Must | — |
NP | — | — | Must | — |
NR | — | — | Must | — |
NT | — | — | Must | — |
NU | — | — | Must | — |
NZ | — | — | Must | — |
OM | — | — | Must | — |
PA | — | — | Must | — |
PE | — | — | Must | — |
PF | — | — | Must | — |
PG | — | — | Must | — |
PH | — | — | Must | — |
PK | — | — | Must | — |
PL | — | — | Must | — |
PM | — | — | Must | — |
PN | — | — | Must | — |
PR | — | — | Must | — |
PS | — | — | Must | — |
PT | — | — | Must | — |
PW | — | — | Must | — |
PY | — | — | Must | — |
QA | — | — | Must | — |
RE | — | — | Must | — |
RO | — | — | Must | — |
RS | — | — | Must | — |
RU | — | — | Must | — |
RW | — | — | Must | — |
SA | — | — | Must | — |
SB | — | — | Must | — |
SC | — | — | Must | — |
SD | — | — | Must | — |
SE | — | — | Must | — |
SF | — | — | Must | — |
SG | — | — | Must | — |
SH | — | — | Must | — |
SI | — | — | Must | — |
SJ | — | — | Must | — |
SK | — | — | Must | — |
SL | — | — | Must | — |
SM | — | — | Must | — |
SN | — | — | Must | — |
SO | — | — | Must | — |
SR | — | — | Must | — |
SS | — | — | Must | — |
ST | — | — | Must | — |
SU | — | — | Must | — |
SV | — | — | Must | — |
SX | — | — | Must | — |
SY | — | — | Must | — |
SZ | — | — | Must | — |
TA | — | — | Must | — |
TC | — | — | Must | — |
TD | — | — | Must | — |
TF | — | — | Must | — |
TG | — | — | Must | — |
TJ | — | — | Must | — |
TK | — | — | Must | — |
TL | — | — | Must | — |
TM | — | — | Must | — |
TN | — | — | Must | — |
TO | — | — | Must | — |
TP | — | — | Must | — |
TR | — | — | Must | — |
TT | — | — | Must | — |
TV | — | — | Must | — |
TW | — | — | Must | — |
TZ | — | — | Must | — |
UA | — | — | Must | — |
UG | — | — | Must | — |
UK | — | — | Must | — |
UM | — | — | Must | — |
US | — | — | Must | — |
UY | — | — | Must | — |
UZ | — | — | Must | — |
VA | — | — | Must | — |
VC | — | — | Must | — |
VE | — | — | Must | — |
VG | — | — | Must | — |
VI | — | — | Must | — |
VN | — | — | Must | — |
VU | — | — | Must | — |
WF | — | — | Must | — |
WS | — | — | Must | — |
XK | — | — | Must | — |
YE | — | — | Must | — |
YT | — | — | Must | — |
YU | — | — | Must | — |
ZA | — | — | Must | — |
ZM | — | — | Must | — |
ZR | — | — | Must | — |
ZW | — | — | Must | — |
| ort 00610 | City | string | Must | — |
| ortsteil 00620 | District | string | Must | — |
| postfach 00630 | PO box | string | Must | — |
| postleitzahl 00640 | Postal code | string | Must | — |
| strasse 00650 | Street | string | Must | — |
| vertragspartner2 [ ] | — | object[] | May | — |
| anrede 00660 | The form of address for the GePa, e.g. Mr. | string | Must | — |
| geschaeftspartnerrolle 00670 | Role held by the business partner (e.g. prospect, customer). | array | Must | — |
| name1 00680 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | Must | — |
| name2 00690 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | Must | — |
| name3 00700 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | Must | — |
| name4 00710 | name4 | string | Must | — |
| VERWENDUNGSZEITRAUM [ ] | — | object[] | May | — |
| datenqualitaet 00720 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| verwendungAb 00730 | verwendungAb | string (date-time) | X | — |
| verwendungBis 00740 | verwendungBis | string (date-time) | X | — |
| zeitraumId 00750 | zeitraumId | integer | Must | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer 00760 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| dokumentennummer * 00770 | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| kategorie * 00780 | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| nachrichtendatum * 00790 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00800 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00810 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 00820 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| transaktionsgrundergaenzung * 00830 | Supplement to the transaction reason / UTILMD STS+7++E01+###+E03 | string | X | — |
| vorgangsnummer * 00840 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00850 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00860 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00870 | Email address | string | Must | — |
| nachname 00880 | Surname (family name) of the contact person | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00890 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00900 | rufnummer | string | Must | — |
| antwortStatusZeitraum [ ] | — | object[] | May | — |
| code 00910 | code | string | X | — |
| liste 00920 | liste | string | X | — |
| zeitraumId 00930 | zeitraumId | integer | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00940 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00950 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55634 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0300070 | Change notifications | — | X | [705] |
1001 Z8800080 | Request for data clearing | — | X | [706] |
100400090 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700100 | Document-/message date/time | — | X | — |
238000110 | Date or time or time span, value | — | X | [931] [494] |
2379 30300120 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00130 | Document-/message sender or sender | — | X | — |
303900140 | MP-ID | — | X | — |
3055 900150 | GS1 | — | X | — |
3055 29300160 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00170 | Information contact | — | X | — |
341200180 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800190 | Number / address | — | X | (([939] [321]) ∨ ([940] [322])) ∧ [514] |
3155 EM00200 | Electronic mail | — | X | [1P0..1] |
3155 FX00210 | Fax number | — | X | [1P0..1] |
3155 TE00220 | Telephone | — | X | [1P0..1] |
3155 AJ00230 | further telephone | — | X | [1P0..1] |
3155 AL00240 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00250 | Message recipient | — | X | — |
303900260 | MP-ID | — | X | — |
3055 900270 | GS1 | — | X | — |
3055 29300280 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400290 | Transaction | — | X | — |
740200300 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700310 | Transaction reason | — | X | — |
9013 ZX600320 | Change data of the MaLo | — | X | — |
9013 ZW300330 | Generating market location | — | X | — |
9013 ZW400340 | Consuming market location | — | X | — |
| SG4.STS | — | — | Must | [301] ∧ [557] ∧ [2011] |
9015 E0100350 | Status of the response | — | X | — |
901300360 | Code of the check step | — | X | — |
1131 E_040900370 | EBD no. E_0409 | — | X | — |
901200380 | Time period ID from the change notification of the responsible party | — | X | [914] ∧ [937] ∧ [44] |
| SG5.LOC | — | — | Must | — |
3227 Z1600390 | Market location | — | X | — |
322500400 | ID of the market location | — | X | [950] |
| SG6.RFF | — | — | Must | — |
1153 Z1300410 | Check identifier | — | X | — |
1154 5563400420 | GPKE / Response message / Request for data of the MaLo from MSB to NB | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00430 | Transaction reference number | — | X | — |
115400440 | Transaction number | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 Z4700450 | Data available in the system | — | X | [5P0..n] |
1153 Z4800460 | Expected data | — | X | [2P0..n] |
1153 Z5400470 | No data available in the system | — | X | [4P0..n] |
1153 Z5500480 | No data expected | — | X | [2P0..n] |
115600490 | Time period ID | — | X | [914] ∧ [937] [127] ⊻ [128] |
| SG6.DTM | — | — | Must | [131] ⊻ [134] ⊻ [135] |
2005 Z2500500 | Data used from | — | X | — |
238000510 | Date or time or time span, value | — | X | [UB1] |
2379 30300520 | CCYYMMDDHHMMZZZ | — | X | — |
| SG6.DTM | — | — | Must | [472] ⊻ [473] |
2005 Z2600530 | Data used until | — | X | — |
238000540 | Date or time or time span, value | — | X | [UB1] |
2379 30300550 | CCYYMMDDHHMMZZZ | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z8000560 | Expected data of the market location | — | X | [2P0..n] |
1229 Z8100570 | Data of the market location existing in the system | — | X | [3P0..n] |
105000580 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG9.QTY | — | — | Must | — |
6063 Z1000590 | Power of the market location | — | X | [102] |
6063 26500600 | Estimated annual quantity total/annual consumption forecast for specific energy for day-parameter-dependent market location | — | X | — |
6063 Z0800610 | Adjusted electrical energy in accordance with Annex D of the VDN guideline "Load profiles for interruptible consumption devices" | — | X | — |
606000620 | Quantity | — | X | [902] |
6411 Z1600630 | kWh/K (kilowatt hour/Kelvin) | — | X | [103] |
6411 KWH00640 | Kilowatt hour | — | X | [104] |
6411 KWT00650 | Kilowatt | — | X | [105] |
| SG9.QTY | — | — | Must | — |
6063 3100660 | Estimated annual quantity total | — | X | — |
606000670 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH00680 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB300690 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9000700 | ÜNB | — | X | — |
113100710 | MP-ID | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9100720 | MSB | — | X | — |
113100730 | MP-ID | — | X | — |
7110 Z3900740 | Default metering point operator | — | X | — |
7110 Z4000750 | Competitive metering point operator | — | X | — |
7110 Z4100760 | Fallback metering point operator | — | X | — |
7110 Z1900770 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2000780 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0300790 | Voltage level of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0300800 | Extra-high voltage | — | X | — |
7111 E0400810 | High voltage | — | X | — |
7111 E0500820 | Medium voltage | — | X | — |
7111 E0600830 | Low voltage | — | X | — |
| SG10.CAV | — | — | Should | [8] |
7111 E0700840 | EHV/HV transformation | — | X | [116] |
7111 E0800850 | HV/MV transformation | — | X | [115] |
7111 E0900860 | MS/NS transformation | — | X | [114] |
| SG10.CCI | — | — | Must | — |
7037 Z8300870 | Metering classification of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z5200880 | iMS | — | X | — |
7111 Z5300890 | kME / mME | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZC000900 | Forecast based on values | — | X | — |
7037 ZA600910 | Forecast based on profiles | — | X | — |
| SG10.CAV | — | — | Must | [210] ∧ ([2182] ⊻ ([90] ∧ [2183])) |
7111 E0200920 | SLP/SEP | — | X | [1P0..1] |
7111 E1400930 | TLP/TEP | — | X | [1P0..1] |
7111 Z3600940 | TEP with reference measurement | — | X | [1P0..1] |
| SG10.CCI | — | — | Must | — |
7037 Z3400950 | Type of the generating market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3300960 | EEG market location without DV obligation | — | X | — |
7111 Z3400970 | KWKG market location without DV obligation | — | X | — |
7111 Z3500980 | other market location | — | X | — |
7111 Z3700990 | EEG market location with DV obligation | — | X | — |
7111 Z4601000 | KWKG market location with DV obligation | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 ZA201010 | Processing model | — | X | — |
7037 ZE901020 | Model 1 "Balancing at the market location" | — | X | — |
7037 ZF001030 | Model 2 "Balancing in the balancing area (BG) of the LPB" | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z8501040 | Expected profile data | — | X | [2P0..n] |
1229 Z8601050 | Profile data available in the system | — | X | [3P0..n] |
105001060 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG10.CCI | — | — | Must | — |
7059 Z0201070 | Standard load profile | — | X | — |
7059 Z0401080 | Standard feed-in profile | — | X | — |
7037 E0101090 | synthetic method | — | X | — |
7037 Z1001100 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711101110 | Code of the standardized profile | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z8701120 | Expected profile set data | — | X | [2P0..n] |
1229 Z8801130 | Profile shard data available in the system | — | X | [3P0..n] |
105001140 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG10.CCI | — | — | Must | — |
7059 Z0301150 | day-parameter-dependent load profile | — | X | — |
7059 Z0501160 | day-parameter-dependent feed-in profile | — | X | — |
7037 E0101170 | synthetic method | — | X | — |
7037 Z1001180 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711101190 | Code of the standardized profile | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z8901200 | Expected reference profile data | — | X | [2P0..n] |
1229 Z9001210 | Reference profile data available in the system | — | X | [3P0..n] |
105001220 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG10.CCI | — | — | Must | — |
705901230 | Class type, code | — | X | — |
| SG10.CAV | — | — | Must | — |
711101240 | Code of the reference profile | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z5101250 | Expected customer of the grid operator | — | X | — |
3035 Z5201260 | Customer of the grid operator available in the system | — | X | — |
303601270 | Name | — | X | — |
3045 Z0101280 | Structure of person names | — | X | — |
3045 Z0201290 | Structure of the company name | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z4601300 | Reference to time period ID | — | X | — |
115401310 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG12.NAD | — | — | Must | — |
3035 Z5301320 | Expected correspondence address of the grid operator's customer | — | X | — |
3035 Z5401330 | Correspondence address of the customer of the grid operator available in the system | — | X | — |
303601340 | Name | — | X | — |
3045 Z0101350 | Structure of person names | — | X | — |
3045 Z0201360 | Structure of the company name | — | X | — |
304201370 | Street and house number or PO box | — | X | — |
316401380 | City | — | X | — |
325101390 | Postal code | — | — | M [268] S [166] |
320701400 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z4601410 | Reference to time period ID | — | X | — |
115401420 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG12.NAD | — | — | Must | — |
3035 Z5501430 | Expected connection holder | — | X | — |
3035 Z5601440 | Connection holder available in the system | — | X | — |
303601450 | Name | — | X | — |
3045 Z0101460 | Structure of person names | — | X | — |
3045 Z0201470 | Structure of the company name | — | X | — |
304201480 | Street and house number or PO box | — | X | — |
316401490 | City | — | X | — |
325101500 | Postal code | — | — | M [268] S [166] |
320701510 | Country name, code | — | — | — |
| SG12.RFF | — | — | Must | — |
1153 Z4601520 | Reference to time period ID | — | X | — |
115401530 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG12.NAD | — | — | Must | — |
3035 Z5701540 | Expected property manager | — | X | — |
3035 Z5801550 | Property manager available in the system | — | X | — |
303601560 | Name | — | X | — |
3045 Z0101570 | Structure of person names | — | X | — |
3045 Z0201580 | Structure of the company name | — | X | — |
304201590 | Street and house number or PO box | — | X | — |
316401600 | City | — | X | — |
325101610 | Postal code | — | — | M [268] S [166] |
320701620 | Country name, code | — | — | — |
| SG12.RFF | — | — | Must | — |
1153 Z4601630 | Reference to time period ID | — | X | — |
115401640 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| UNT | — | — | Must | — |
007401650 | Number of segments in a message | — | X | — |
006201660 | Message reference number | — | X | — |
Conditions of this table
The free text of the 45 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [8] | If required for data clearing |
| [22] | The time period ID from DE1156 of a matching SG6 RFF+Z47/Z48/Z49 (usage period of the data) must be entered |
| [44] | The time period ID from DE1156 of a matching SG6 RFF+Z49/Z53 (usage period of the data: "valid data", "no data") from the request message from SG6 RFF+TN DE1154 ((reference transaction number (from request message)) must be entered |
| [90] | If SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) present once with CAV+E14 (TLP/TEP) and once with CAV+E02 (SLP/SEP) in this SG8 |
| [102] | If SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) CAV+Z36 (TEP with ref. measurement) present in this SG8 |
| [103] | If SG9 QTY+265 (energy / power for day-parameter-dependent market location: estimated annual quantity total) present in this SG8 |
| [104] | If SG9 QTY+Z08 (energy / power for day-parameter-dependent market location: adjusted electrical energy according to Annex D) present in this SG8 |
| [105] | If SG9 QTY+Z10 (energy / power for day-parameter-dependent market location: power of the market location) present in this SG8 |
| [114] | If the SG10 CCI+E03 (voltage level of the market location) CAV E06 (low voltage) is present in this SG |
| [115] | If the SG10 CCI+E03 (voltage level of the market location) CAV E05 (medium voltage) is present in this SG |
| [116] | If the SG10 CCI+E03 (voltage level of the market location) CAV E04 (high voltage) is present in this SG |
| [127] | The value resulting from the number of repetitions of the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) must be entered. This means: the first SG6 RFF+Z48/Z55 thus has the „1“, the second the „2“, the third the „3“, etc. |
| [128] | The value resulting from the number of repetitions of the SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) must be entered. This means: the first SG6 RFF+Z47/Z54 thus has the „1“, the second the „2“, the third the „3“, etc. |
| [131] | If this DTM+Z25 (use of the data from) in SG6 RFF (usage period of the data) is marked with the time period ID "1" in DE1156, the date in this DE2380 must be the day immediately following DTM+137 DE2380 (message date) at 0:00, or a day earlier than that at 0:00 German time |
| [134] | If this DTM+Z25 (use of data from) is not in the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) with time period ID "1" in DE1156, the date must correspond to the DTM+Z26 (use of data until) of the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) with the next lower time period ID in DE1156 |
| [135] | If this DTM+Z25 (use of data from) is not in the SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) with time period ID "1" in DE1156, the date must correspond to the DTM+Z26 (use of data until) of the SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) with the next lower time period ID in DE1156 |
| [166] | If present |
| [210] | If SG10 CCI+++ZA6 (forecast based on profiles) present in this SG8 |
| [268] | If an "X" is listed for the code in DE3207 in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| [301] | If BGM+E03 (change notification) present |
| [321] | If code EM is present in DE3155 in the same COM |
| [322] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [472] | If a time period ID is named in DE1156 (time period ID) in the same SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) which is lower than in another SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) DE1156 (time period ID) |
| [473] | If a time period ID is named in DE1156 (time period ID) in the same SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) which is lower than in another SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) DE1156 (time period ID) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [557] | Note: If the responsible party has sent more than eight usage periods, eight arbitrary usage periods are answered |
| [705] | Note: If the action of a sequence diagram "Response message on change" is carried out |
| [706] | Note: If the action of a sequence diagram "Order placement of a change of master data..." is carried out with the aim of performing a data clearing |
| [902] | Format: Possible value: ≥ 0 |
| [914] | Format: Possible value: > 0 |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [2011] | Segment group must be specified exactly once for each time period ID from DE1156 of the SG6 RFF+Z49 / Z53 (usage period of the data: "Valid data" / "No data") from the request message from SG6 RFF+TN DE1154 (reference transaction number (from request message)) |
| [2182] | Segment group must be specified exactly once per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2183] | Segment group must be specified exactly twice per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [5P0..n] | [315] If BGM+Z88 (data clearing) present [20 13 ] To be specified at least once , if no SG6 RFF+Z54 (Usage period of the data: no data present in the system) present |
| [2P0..n] | [301] If BGM+E03 (change notification) present [315] If BGM+Z88 (data clearing) present |
| [4P0..n] | [315] If BGM+Z88 (data clearing) present [20 14 ] To be specified at least once , if no SG6 RFF+Z47 (Usage period of the data: data present in the system) present |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [3P0..n] | [315] If BGM+Z88 (data clearing) present |
Example message
Example 1
UNA:+.? '
UNB+UNOC:3+9910812000000:500+9900327000009:500+{{date}}:{{time}}+DARBBWTPSBVNKX'
UNH+DAWBDMIKKERHKR+UTILMD:D:11A:UN:S2.1'
BGM+E03+DA262410220812389903323000007090610'
DTM+137:202506241231?+00:303'
NAD+MS+9910812000000::293'
CTA+IC+:P GETTY'
COM+?+3222271020:TE'
NAD+MR+9900327000009::293'
IDE+24+24062416225400000000000102159662011'
STS+7++ZX6+ZW4'
STS+E01++A02:E_0409::1'
STS+E01++A02:E_0409::2'
LOC+Z16+20072281644'
RFF+Z13:55634'
RFF+TN:NNV1234'
RFF+Z48::1'
DTM+Z25:202506232200?+00:303'
DTM+Z26:202507232200?+00:303'
RFF+Z48::2'
DTM+Z25:202507232200?+00:303'
SEQ+Z80+1'
QTY+31:4000:KWH'
CCI+++ZB3'
CAV+Z90:9911835000001'
CAV+Z91:9910812000000::Z39:Z19'
CCI+++E03'
CAV+E06'
CAV+E09'
CCI+++Z83'
CAV+Z52'
CCI+++ZA6'
CAV+E02'
CCI+ZA2++ZE9'
SEQ+Z80+2'
QTY+31:4100:KWH'
CCI+++ZB3'
CAV+Z90:9911835000001'
CAV+Z91:9910812000000::Z39:Z19'
CCI+++E03'
CAV+E06'
CAV+E09'
CCI+++Z83'
CAV+Z52'
CCI+++ZA6'
CAV+E02'
CCI+ZA2++ZE9'
SEQ+Z85+1'
CCI+Z02++E01'
CAV+XYZ'
SEQ+Z85+2'
CCI+Z02++E01'
CAV+XYZ'
NAD+Z51+++Firma AG:Musterfirma::::Z02'
RFF+Z46:1'
NAD+Z53+++Fank Müller:::::Z01+Wohnstrasse::25:Musterortsteil+Musterstadt++55555+DE'
RFF+Z46:1'
NAD+Z55+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:1'
NAD+Z57+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:1'
NAD+Z51+++Firma AG:Musterfirma::::Z02'
RFF+Z46:2'
NAD+Z53+++Fank Müller:::::Z01+Wohnstrasse::25:Musterortsteil+Musterstadt++55555+DE'
RFF+Z46:2'
NAD+Z55+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:2'
NAD+Z57+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:2'
UNT+68+DAWBDMIKKERHKR'
UNZ+1+DARBBWTPSBVNKX'[1 item
{6 fields
"data": {3 fields
"stammdaten": {4 fields
"VERWENDUNGSZEITRAUM": [2 items
{6 fields
{5 fields
"MARKTLOKATION": [2 items
{12 fields
"gueltigkeitszeitraum": {3 fields
"marktrollen": [2 items
{6 fields
{8 fields
"eigentuemer": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
"hausverwalter": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
{12 fields
"gueltigkeitszeitraum": {2 fields
"marktrollen": [2 items
{6 fields
{8 fields
"eigentuemer": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
"hausverwalter": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
"NETZNUTZUNGSVERTRAG": [2 items
{10 fields
"gueltigkeitszeitraum": {3 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"korrespondenzpartner": {5 fields
"partneradresse": {6 fields
{10 fields
"gueltigkeitszeitraum": {2 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"korrespondenzpartner": {5 fields
"partneradresse": {6 fields
"BILANZIERUNG": [2 items
{9 fields
"gueltigkeitszeitraum": {3 fields
"lastprofile": [1 item
{5 fields
"jahresverbrauchsprognose": {2 fields
"detailsPrognosegrundlage": [1 item
{9 fields
"gueltigkeitszeitraum": {2 fields
"lastprofile": [1 item
{5 fields
"jahresverbrauchsprognose": {2 fields
"detailsPrognosegrundlage": [1 item
"transaktionsdaten": {14 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"rufnummern": [1 item
{2 fields
"empfaenger": {5 fields
"antwortStatusZeitraum": [2 items
{3 fields
{3 fields
Download: EDIFACT file · BO4E JSON
Example 2
UNA:+.? '
UNB+UNOC:3+9910812000000:500+9900327000009:500+{{date}}:{{time}}+DAIUIHDBGNDQCV'
UNH+DAWHPFFDUZEGZP+UTILMD:D:11A:UN:S2.1'
BGM+E03+DA102410220806209903323000007895460'
DTM+137:202506241231?+00:303'
NAD+MS+9910812000000::293'
CTA+IC+:P GETTY'
COM+?+3222271020:TE'
NAD+MR+9900327000009::293'
IDE+24+24062416225400000000000102159662011'
STS+7++ZX6+ZW4'
STS+E01++A02:E_0409::1'
STS+E01++A02:E_0409::2'
LOC+Z16+20072281644'
RFF+Z13:55634'
RFF+TN:NNV1234'
RFF+Z48::1'
DTM+Z25:202506232200?+00:303'
DTM+Z26:202507232200?+00:303'
RFF+Z48::2'
DTM+Z25:202507232200?+00:303'
SEQ+Z80+1'
QTY+265:3:Z16'
CCI+++ZB3'
CAV+Z90:9911835000001'
CAV+Z91:9910812000000::Z39:Z19'
CCI+++E03'
CAV+E06'
CAV+E09'
CCI+++Z83'
CAV+Z52'
CCI+++ZA6'
CAV+E14'
CCI+ZA2++ZE9'
SEQ+Z80+2'
QTY+265:3:Z16'
CCI+++ZB3'
CAV+Z90:9911835000001'
CAV+Z91:9910812000000::Z39:Z19'
CCI+++E03'
CAV+E06'
CAV+E09'
CCI+++Z83'
CAV+Z52'
CCI+++ZA6'
CAV+E14'
CCI+ZA2++ZE9'
SEQ+Z87+1'
CCI+Z03++E01'
CAV+XYZ'
SEQ+Z87+2'
CCI+Z03++E01'
CAV+XYZ'
NAD+Z51+++Firma AG:Musterfirma::::Z02'
RFF+Z46:1'
NAD+Z53+++Fank Müller:::::Z01+Wohnstrasse::25:Musterortsteil+Musterstadt++55555+DE'
RFF+Z46:1'
NAD+Z55+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:1'
NAD+Z57+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:1'
NAD+Z51+++Firma AG:Musterfirma::::Z02'
RFF+Z46:2'
NAD+Z53+++Fank Müller:::::Z01+Wohnstrasse::25:Musterortsteil+Musterstadt++55555+DE'
RFF+Z46:2'
NAD+Z55+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:2'
NAD+Z57+++Huber:Karlheinz:::Dr.:Z01+Teststraße::815b:X+Entenhausen++10010+DE'
RFF+Z46:2'
UNT+68+DAWHPFFDUZEGZP'
UNZ+1+DAIUIHDBGNDQCV'[1 item
{6 fields
"data": {3 fields
"stammdaten": {4 fields
"VERWENDUNGSZEITRAUM": [2 items
{6 fields
{5 fields
"MARKTLOKATION": [2 items
{12 fields
"gueltigkeitszeitraum": {3 fields
"marktrollen": [2 items
{6 fields
{8 fields
"eigentuemer": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
"hausverwalter": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
{12 fields
"gueltigkeitszeitraum": {2 fields
"marktrollen": [2 items
{6 fields
{8 fields
"eigentuemer": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
"hausverwalter": {8 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {6 fields
"NETZNUTZUNGSVERTRAG": [2 items
{10 fields
"gueltigkeitszeitraum": {3 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"korrespondenzpartner": {5 fields
"partneradresse": {6 fields
{10 fields
"gueltigkeitszeitraum": {2 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"korrespondenzpartner": {5 fields
"partneradresse": {6 fields
"BILANZIERUNG": [2 items
{9 fields
"gueltigkeitszeitraum": {3 fields
"lastprofile": [1 item
{5 fields
"temperaturarbeit": {2 fields
"detailsPrognosegrundlage": [1 item
{9 fields
"gueltigkeitszeitraum": {2 fields
"lastprofile": [1 item
{5 fields
"temperaturarbeit": {2 fields
"detailsPrognosegrundlage": [1 item
"transaktionsdaten": {14 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"rufnummern": [1 item
{2 fields
"empfaenger": {5 fields
"antwortStatusZeitraum": [2 items
{3 fields
{3 fields
Download: EDIFACT file · BO4E JSON
Example 3
UNA:+.? '
UNB+UNOC:3+9910812000000:500+9900327000009:500+{{date}}:{{time}}+DAYKDYVSLAJQWH'
UNH+DAAFSOQVKKNGXK+UTILMD:D:11A:UN:S2.1'
BGM+E03+DA172410220759199903323000007215798'
DTM+137:202506241231?+00:303'
NAD+MS+9910812000000::293'
CTA+IC+:P GETTY'
COM+?+3222271020:TE'
NAD+MR+9900327000009::293'
IDE+24+24062416225400000000000102159662011'
STS+7++ZX6+ZW3'
STS+E01++A02:E_0409::1'
STS+E01++A02:E_0409::2'
LOC+Z16+20072281644'
RFF+Z13:55634'
RFF+TN:NNV1234'
RFF+Z48::1'
DTM+Z25:202506232200?+00:303'
DTM+Z26:202507232200?+00:303'
RFF+Z48::2'
DTM+Z25:202507232200?+00:303'
SEQ+Z80+1'
QTY+Z10:3:KWT'
CCI+++ZB3'
CAV+Z90:9911835000001'
CAV+Z91:9910812000000::Z39:Z19'
CCI+++E03'
CAV+E06'
CAV+E09'
CCI+++Z83'
CAV+Z52'
CCI+++ZA6'
CAV+Z36'
CCI+++Z34'
CAV+Z33'
CCI+ZA2++ZE9'
SEQ+Z80+2'
QTY+Z10:3:KWT'
CCI+++ZB3'
CAV+Z90:9911835000001'
CAV+Z91:9910812000000::Z39:Z19'
CCI+++E03'
CAV+E06'
CAV+E09'
CCI+++Z83'
CAV+Z52'
CCI+++ZA6'
CAV+Z36'
CCI+++Z34'
CAV+Z33'
CCI+ZA2++ZE9'
SEQ+Z89+1'
CCI+Z05'
CAV+XYZ'
SEQ+Z89+2'
CCI+Z05'
CAV+XYZ'
UNT+56+DAAFSOQVKKNGXK'
UNZ+1+DAYKDYVSLAJQWH'[1 item
{6 fields
"data": {3 fields
"stammdaten": {3 fields
"VERWENDUNGSZEITRAUM": [2 items
{6 fields
{5 fields
"MARKTLOKATION": [2 items
{11 fields
"gueltigkeitszeitraum": {3 fields
"marktrollen": [2 items
{6 fields
{8 fields
"energieherkunft": [1 item
{1 field
{11 fields
"gueltigkeitszeitraum": {2 fields
"marktrollen": [2 items
{6 fields
{8 fields
"energieherkunft": [1 item
{1 field
"BILANZIERUNG": [2 items
{9 fields
"gueltigkeitszeitraum": {3 fields
"lastprofile": [1 item
{2 fields
"temperaturarbeit": {2 fields
"detailsPrognosegrundlage": [1 item
{9 fields
"gueltigkeitszeitraum": {2 fields
"lastprofile": [1 item
{2 fields
"temperaturarbeit": {2 fields
"detailsPrognosegrundlage": [1 item
"transaktionsdaten": {14 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"rufnummern": [1 item
{2 fields
"empfaenger": {5 fields
"antwortStatusZeitraum": [2 items
{3 fields
{3 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ÜNB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Order placement for a master data change to the NB (responsible) | GPKE part 4 | Electricity | Step 3 |
| LF | LF | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 5 |
| NB | NB | Order placement for a master data change to the NB (responsible) | GPKE part 4 | Electricity | Step 3 |
| NB | NB | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 5 |
| MSB | MSB | Order placement for a master data change to the NB (responsible) | GPKE part 4 | Electricity | Step 3 |
| MSB | MSB | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 5 |
| ÜNB | ÜNB | Order placement for a master data change to the NB (responsible) | GPKE part 4 | Electricity | Step 3 |
| ÜNB | ÜNB | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 5 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response message/request data of the MaLo |
| AHB | UTILMD AHB electricity |
| Response to check identifier | 55628 |
| Decision tree | E_0409 |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 4 | Master data change initiated by the NB (responsible) | MSB → NB | Response message on change |
| GPKE part 4 | Order placement for master data change to NB (responsible) | MSB → NB | Order placement of a change of master data from the MSB to NB |
One entry from format version 202610
The check identifiers table of format version 202604 does not carry this entry: decision tree. It comes from version 202610. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202604.
Transaction and responses
Role of this check identifier: response message. Basis: the title or the action of the Prüfi table begins with “response message”. A response message carries no status field and is not a response in the sense of a decision tree.
Responses: No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDS has the same row structure in this version.
Editorial — not derived from a source
The period ID of this response comes from the request. Condition [44] requires in STS DE9012: »Es ist die Zeitraum-ID vom DE1156 aus einem passenden SG6 RFF+Z49/Z53 … einzutragen« (the period ID from DE1156 of a matching SG6 RFF+Z49/Z53 of the request). In the JSON it is in transaktionsdaten.antwortStatusZeitraum → zeitraumId (SG4.IDE+24.STS+E01). Its value is the zeitraumId of the request's usage period that the response refers to: stammdaten.VERWENDUNGSZEITRAUM → zeitraumId (SG4.IDE+24.SG6.RFF+[Z49|Z53]).
Source: UTILMD AHB electricity (Knowledge Collection ahb/202604/UTILMDS and ahb/202610/UTILMDS), condition [44] at SG4 STS DE9012; segment mapping of the zeitraumId fields in the check identifier specifications · As of: 2026-09-23 · Applies to format version: 202604, 202610 · To be reviewed by: 2027-04-01
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 216 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains 3 transactions for this check identifier under the message type utilmd. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.