Check identifier 55043 — Confirmation of registration MSB
Check identifier 55043 · EDIFACT message type UTILMD · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 55043 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| BILANZIERUNG [ ] | — | object[] | May | — |
| abwicklungsmodell 00010 | Processing model | Enum Abwicklungsmodell | Must | — |
MODELL_1_BILANZIERUNG_AN_MARKTLOKATION | — | — | Must | — |
MODELL_2_BILANZIERUNG_IM_BILANZIERUNGSGEBIET | — | — | Must | — |
| aggregationsverantwortung 00020 | Aggregation responsibility | Enum Aggregationsverantwortung | X | — |
UENB | — | — | X | — |
VNB | — | — | X | — |
| detailsPrognosegrundlage 00030 | Forecast basis - If a day-parameter-dependent load profile with joint metering has to be specified, this is possible by repeating the CAV segment twice, stating the codes E02 and E14. | array | Must | — |
| marktlokationsId 00040 | Which market location these balancing data apply to | string | X | — |
| prognosegrundlage 00050 | Forecast basis | Enum Prognosegrundlage | Must | — |
WERTE | — | — | Must | — |
PROFILE | — | — | Must | — |
| jahresverbrauchsprognose | — | object | May | — |
| einheit 00060 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 00070 | Value | number (float) | X | — |
| lastprofile [ ] | — | object[] | May | — |
| bezeichnung 00080 | Designation of the profile | string | Must | — |
| einspeisung 00090 | Feed-in indicator | boolean | Must | — |
| profilart 00100 | Profile category | Enum Profilart | Must | — |
ART_STANDARDLASTPROFIL | — | — | Must | — |
ART_TAGESPARAMETERABHAENGIGES_LASTPROFIL | — | — | Must | — |
ART_LASTPROFIL | — | — | Must | — |
| referenzprofilbezeichnung 00110 | Designation of the reference profile | string | Must | — |
| verfahren 00120 | Profiling method | Enum Profilverfahren | Must | — |
SYNTHETISCH | — | — | Must | — |
ANALYTISCH | — | — | Must | — |
| tagesparameter | — | object | May | — |
| dienstanbieter 00130 | dienstanbieter | string | Must | — |
| herausgeber 00140 | Herausgeber | Enum Herausgeber | Must | — |
NB | — | — | Must | — |
BDEW | — | — | Must | — |
TUM | — | — | Must | — |
| klimazone 00150 | klimazone | string | Must | — |
| temperaturmessstelle 00160 | temperaturmessstelle | string | Must | — |
| temperaturarbeit | — | object | May | — |
| einheit 00170 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 00180 | Value | number (float) | X | — |
| ENERGIELIEFERVERTRAG [ ] | — | object[] | May | — |
| lokationsId 00190 | lokationsId | string | X | — |
| korrespondenzpartner | — | object | May | — |
| anrede 00200 | The form of address for the GePa, e.g. Mr. | string | X | — |
| name1 00210 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00220 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00230 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00240 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 00250 | House number and supplement | string | X | — |
| landescode 00260 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00270 | City | string | X | — |
| ortsteil 00280 | District | string | X | — |
| postfach 00290 | PO box | string | X | — |
| postleitzahl 00300 | Postal code | string | X | — |
| strasse 00310 | Street | string | X | — |
| vertragspartner2 [ ] | — | object[] | May | — |
| anrede 00320 | The form of address for the GePa, e.g. Mr. | string | X | — |
| geschaeftspartnerrolle 00330 | Role held by the business partner (e.g. prospect, customer). | array | X | — |
| name1 00340 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00350 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00360 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00370 | name4 | string | X | — |
| LOKATIONSBUENDEL [ ] * | — | object[] | Must | — |
| lokationsbuendelNummer 00380 | lokationsbuendelNummer | integer | Must | — |
| lokationsbuendelstrukturId 00390 | lokationsbuendelstrukturId | string | Must | — |
| standardisierteLokationsbuendelstruktur * 00400 | standardisierteLokationsbuendelstruktur | boolean | Must | — |
| zuordnungObjectcode [ ] | — | object[] | May | — |
| referenzLokationsId 00410 | referenzLokationsId | string | Must | — |
| referenzLokationsTyp 00420 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| referenzMarktlokationTechnischeRessource 00430 | referenzMarktlokationTechnischeRessource | array | X | — |
| vorgelagerteLokationId 00440 | vorgelagerteLokationId | string | Must | — |
| vorgelagerteLokationTyp 00450 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| objectcode [ ] | — | object[] | May | — |
| lokationsbuendelNummer 00460 | lokationsbuendelNummer | integer | X | — |
| objectcode 00470 | objectcode | string | X | — |
| MARKTLOKATION [ ] * | — | object[] | Must | — |
| energierichtung 00480 | Indicates whether energy is fed in or drawn (fed out). | Enum Energierichtung | X | — |
AUSSP | — | — | X | — |
EINSP | — | — | X | — |
| marktlokationsId * 00490 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| messtechnischeEinordnung 00500 | Metering classification from the UTILMD (IMS, KME_MME, KEINE_MESSUNG) | Enum MesstechnischeEinordnung | Must | — |
IMS | — | — | Must | — |
KME_MME | — | — | Must | — |
KEINE_MESSUNG | — | — | Must | — |
| netzebene 00510 | Grid level at which the energy is drawn. For electricity, the voltage level of the supply; for gas, the pressure level. Example electricity: low voltage Example gas: low pressure. | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| energieherkunft [ ] | — | object[] | May | — |
| erzeugungsart 00520 | Type of generation | Enum Erzeugungsart | Must | — |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00530 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00540 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00550 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00560 | weiterverpflichtet | boolean | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 00570 | messprodukt | string | X | — |
| obisKennzahl 00580 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| verwendungszweckLF 00590 | Codes according to the code list of the purposes of use Purpose of use LF | string | X | — |
| verwendungszweckNB 00600 | Codes according to the code list of the purposes of use Purpose of use NB | string | X | — |
| verwendungszweckUENB 00610 | Codes according to the code list of the purposes of use Purpose of use ÜNB | string | X | — |
| wertegranularitaet 00620 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| zaehlzeiten | — | object | May | — |
| register 00630 | Metering time period register | string | X | — |
| zaehlzeitDefinition 00640 | Metering time period definition | string | X | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| betriebszustand 00650 | Operating state | Enum Betriebszustand | X | — |
GESPERRT_NICHT_ENTSPERREN | — | — | X | — |
GESPERRT | — | — | X | — |
REGELBETRIEB | — | — | X | — |
AUSSERHALB_REGELBETRIEB | — | — | X | — |
| datenqualitaet 00660 | Data quality | Enum Datenqualitaet | X | — |
ERWARTETE_DATEN | — | — | X | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | X | — |
INFORMATIVE_DATEN | — | — | X | — |
GUELTIGE_DATEN | — | — | X | — |
KEINE_DATEN | — | — | X | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | X | — |
KEINE_DATEN_ERWARTET | — | — | X | — |
DIFFERENZ_DATEN | — | — | X | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | X | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | X | — |
| messlokationsId * 00670 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| netzebenemessung 00680 | Grid level | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| referenzMarktlokationsId 00690 | referenzMarktlokationsId | string | X | — |
| verwendungsumfang 00700 | Scope of use | Enum Verwendungsumfang | X | — |
MESSLOKATION_PROZESSUAL_BEHANDELT | — | — | X | — |
MESSLOKATION_LOKATIONSBUENDEL | — | — | X | — |
| ablesekartenempfaenger * | — | object | Must | — |
| anrede 00710 | The form of address for the GePa, e.g. Mr. | string | X | — |
| gewerbekennzeichnung 00720 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | X | — |
| name1 * 00730 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00740 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00750 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00760 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 00770 | House number and supplement | string | X | — |
| landescode 00780 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00790 | City | string | X | — |
| ortsteil 00800 | District | string | X | — |
| postfach 00810 | PO box | string | X | — |
| postleitzahl 00820 | Postal code | string | X | — |
| strasse 00830 | Street | string | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00840 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00850 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00860 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00870 | weiterverpflichtet | boolean | X | — |
| messadresse | — | object | May | — |
| hausnummer 00880 | House number and supplement | string | X | — |
| landescode 00890 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00900 | City | string | X | — |
| ortsteil 00910 | District | string | X | — |
| postfach 00920 | PO box | string | X | — |
| postleitzahl 00930 | Postal code | string | X | — |
| strasse 00940 | Street | string | X | — |
| zusatzInformation | — | object | May | — |
| zusatz1 00950 | Address supplement 1 | string | X | — |
| zusatz2 00960 | Address supplement 2 | string | X | — |
| zusatz3 00970 | Address supplement 3 | string | X | — |
| zusatz4 00980 | Address supplement 4 | string | X | — |
| zusatz5 00990 | Address supplement 5 | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 01000 | messprodukt | string | X | — |
| notwendigkeitZweiteMessung 01010 | Necessity of second measurement | Enum NotwendigkeitZweiteMessung | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| werteuebermittlungVerwendungszweck 01020 | Purpose of use for value transmission | Enum WerteuebermittlungVerwendungszweck | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| zaehlzeiten | — | object | May | — |
| zaehlzeitDefinition 01030 | Metering time period definition | string | Must | — |
| MESSSTELLENBETRIEBSVERTRAG [ ] * | — | object[] | Must | — |
| lokationsId * 01040 | lokationsId | string | X | — |
| lokationsTyp * 01050 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | X | — |
MALO | — | — | X | — |
MELO | — | — | X | — |
NELO | — | — | X | — |
TECHNISCHE_RESSOURCE | — | — | X | — |
STEUERBARE_RESSOURCE | — | — | X | — |
TRANCHE | — | — | X | — |
MABIS_ZAEHLPUNKT | — | — | X | — |
| korrespondenzpartner * | — | object | Must | — |
| anrede 01060 | The form of address for the GePa, e.g. Mr. | string | X | — |
| name1 * 01070 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 01080 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 01090 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 01100 | name4 | string | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 01110 | Email address | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 01120 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 01130 | rufnummer | string | Must | — |
| partneradresse | — | object | May | — |
| hausnummer 01140 | House number and supplement | string | X | — |
| landescode 01150 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 01160 | City | string | X | — |
| ortsteil 01170 | District | string | X | — |
| postfach 01180 | PO box | string | X | — |
| postleitzahl 01190 | Postal code | string | X | — |
| strasse 01200 | Street | string | X | — |
| vertragskonditionen | — | object | May | — |
| geplanteTurnusablesung | — | object | May | — |
| ableseZeitraum 01210 | ableseZeitraum | string | X | — |
| vertragspartner2 [ ] * | — | object[] | Must | — |
| anrede 01220 | The form of address for the GePa, e.g. Mr. | string | X | — |
| geschaeftspartnerrolle 01230 | Role held by the business partner (e.g. prospect, customer). | array | X | — |
| name1 * 01240 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 01250 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 01260 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 01270 | name4 | string | X | — |
| NETZLOKATION [ ] | — | object[] | May | — |
| konfigurationsprodukt 01280 | konfigurationsprodukt | string | X | — |
| leistungskurvendefinition 01290 | Code of the assigned power curve definition for the object | string | X | — |
| netzlokationsId 01300 | Identification number of a grid location at which energy is either consumed or generated (like MarktlokationsId market location) | string | X | — |
| produktdatenRelevanteRolle 01310 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| steuerkanal 01320 | Whether a control channel is assigned to the grid location and the grid location can therefore be controlled. ZF2: No control channel present ZF3: Control channel present | boolean | X | — |
| auftraggebenderMarktpartner | — | object | May | — |
| marktrolle 01330 | Indicates the designation of the market role in free text. | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| rollencodenummer 01340 | Specifies the code value of the market role. | string | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 01350 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 01360 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 01370 | Specifies the code value of the market role. | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| keinProdukt 01380 | CCI+11++ZF6: no product assigned | boolean | X | — |
| obisKennzahl 01390 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| verwendungszweckLF 01400 | Codes according to the code list of the purposes of use Purpose of use LF | string | X | — |
| verwendungszweckNB 01410 | Codes according to the code list of the purposes of use Purpose of use NB | string | X | — |
| STEUERBARE_RESSOURCE [ ] | — | object[] | May | — |
| keinKonfigurationsprodukt 01420 | keinKonfigurationsprodukt | boolean | X | — |
| konfigurationsprodukt 01430 | konfigurationsprodukt | string | X | — |
| produktdatenRelevanteRolle 01440 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| ressourcenId 01450 | ressourcenId | string | X | — |
| steuerkanal 01460 | Control channel | Enum Steuerkanal | X | — |
AN_AUS | — | — | X | — |
GESTUFT | — | — | X | — |
| auftraggebenderMarktpartner | — | object | May | — |
| marktrolle 01470 | Indicates the designation of the market role in free text. | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| rollencodenummer 01480 | Specifies the code value of the market role. | string | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 01490 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 01500 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 01510 | Specifies the code value of the market role. | string | X | — |
| zugeordneteDefinition | — | object | May | — |
| leistungskurvendefinition 01520 | leistungskurvendefinition | string | Must | — |
| schaltzeitdefinition 01530 | schaltzeitdefinition | string | Must | — |
| TECHNISCHE_RESSOURCE [ ] | — | object[] | May | — |
| art 01540 | Technical resource type | Enum TechnischeRessourceArt | Must | — |
STROMERZEUGUNG | — | — | Must | — |
STROMVERBRAUCH | — | — | Must | — |
SPEICHER | — | — | Must | — |
| artEMobilitaet 01550 | ArtEmobilitaet | Enum ArtEmobilitaet | Must | — |
WB | — | — | Must | — |
LS | — | — | Must | — |
LP | — | — | Must | — |
| enwg 01560 | enwg | boolean | Must | — |
| erzeugungsart 01570 | Type of energy generation. Details generation type Example: CAV+ZF5' Generation type: ZF5: solar ZF6: wind ZG0: gas ZG1: water ZG5: other generation type | Enum Erzeugungsart | Must | — |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| referenzNetzlokation 01580 | referenzNetzlokation | string | X | — |
| referenzSteuerbareRessource 01590 | referenzSteuerbareRessource | string | X | — |
| referenzTranche 01600 | referenzTranche | string | X | — |
| ressourcenId 01610 | ressourcenId | string | X | — |
| speicherart 01620 | Type of storage. Details storage type Example: CAV+ZF7' Storage type: ZF7: hydrogen storage ZF8: pumped storage ZF9: battery storage ZG6: other storage type | Enum Speicherart | Must | — |
WASSERSTOFFSPEICHER | — | — | Must | — |
PUMPSPEICHER | — | — | Must | — |
BATTERIESPEICHER | — | — | Must | — |
SONSTIGE_SPEICHERART | — | — | Must | — |
| speicherkapazitaet 01630 | Storage capacity Example: QTY+Z42:100:KWH' | number (float) | X | — |
| verbrauchsart 01640 | Consumption type of the technical resource Example: CAV+Z64' Z64: Power/light Z65: Heat ZE5: E-mobility ZA8: Street lighting | array | Must | — |
| waermenutzung 01650 | Heat usage Example: CAV+Z56' Z56: Storage heating Z57: Heat pump Z61: Direct heating | Enum Waermenutzung | Must | — |
SPEICHERHEIZUNG | — | — | Must | — |
WAERMEPUMPE | — | — | Must | — |
DIREKTHEIZUNG | — | — | Must | — |
WAERMEPUMPE_WAERME_KAELTE | — | — | Must | — |
WAERMEPUMPE_KAELTE | — | — | Must | — |
WAERMEPUMPE_WAERME | — | — | Must | — |
| nennleistung | — | object | May | — |
| abgabe 01660 | Submission of the rated capacity | number (float) | X | — |
| aufnahme 01670 | Recording of the rated power | number (float) | X | — |
| TRANCHE [ ] | — | object[] | May | — |
| bildungTranchengroesse 01680 | BildungTranchengroesse | Enum BildungTranchengroesse | X | — |
PROZENTUAL | — | — | X | — |
AUFTEILUNGSFAKTOR | — | — | X | — |
AUFTEILUNG_TECHNISCHE_RESSOURCEN | — | — | X | — |
BERECHNUNGSFORMEL | — | — | X | — |
| referenzMarktlokationsId 01690 | referenzMarktlokationsId | string | X | — |
| tranchenId 01700 | tranchenId | string | X | — |
| aufteilungsmenge | — | object | May | — |
| einheit 01710 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 01720 | Value | number (float) | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 01730 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| rollencodenummer 01740 | Specifies the code value of the market role. | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 01750 | messprodukt | string | X | — |
| verwendungszweckLF 01760 | Codes according to the code list of the purposes of use Purpose of use LF | string | X | — |
| verwendungszweckNB 01770 | Codes according to the code list of the purposes of use Purpose of use NB | string | X | — |
| verwendungszweckUENB 01780 | Codes according to the code list of the purposes of use Purpose of use ÜNB | string | X | — |
| ZAEHLER [ ] | — | object[] | May | — |
| befestigungsart 01790 | Mounting type | Enum Befestigungsart | Must | — |
STECKTECHNIK | — | — | Must | — |
DREIPUNKT | — | — | Must | — |
HUTSCHIENE | — | — | Must | — |
EINSTUTZEN | — | — | Must | — |
ZWEISTUTZEN | — | — | Must | — |
| fernschaltung 01800 | Remote switching | Enum Fernschaltung | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| gateway 01810 | Specification of a SMGW with which the meter is parameterised | string | X | — |
| marktlokationsId 01820 | marktlokationsId | string | X | — |
| messlokationsId 01830 | messlokationsId | string | X | — |
| messwerterfassung 01840 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| tarifart 01850 | Specification regarding supported tariff types. | Enum Tarifart | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
SMART_METER | — | — | Must | — |
LEISTUNGSGEMESSEN | — | — | Must | — |
| zaehlerauspraegung 01860 | Specification regarding the direction of the meter. | Enum Zaehlerauspraegung | Must | — |
EINRICHTUNGSZAEHLER | — | — | Must | — |
ZWEIRICHTUNGSZAEHLER | — | — | Must | — |
| zaehlernummer 01870 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 01880 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 01890 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 01900 | The number printed on the device, which is assigned by the MSB. | string | X | — |
| geraetetyp 01910 | List of possible billable device types | Enum Geraetetyp | X | — |
WECHSELSTROMZAEHLER | — | — | X | — |
DREHSTROMZAEHLER | — | — | X | — |
ZWEIRICHTUNGSZAEHLER | — | — | X | — |
RLM_ZAEHLER | — | — | X | — |
IMS_ZAEHLER | — | — | X | — |
BALGENGASZAEHLER | — | — | X | — |
MAXIMUMZAEHLER | — | — | X | — |
MULTIPLEXANLAGE | — | — | X | — |
PAUSCHALANLAGE | — | — | X | — |
VERSTAERKERANLAGE | — | — | X | — |
SUMMATIONSGERAET | — | — | X | — |
IMPULSGEBER | — | — | X | — |
EDL_21_ZAEHLERAUFSATZ | — | — | X | — |
VIER_QUADRANTEN_LASTGANGZAEHLER | — | — | X | — |
MENGENUMWERTER | — | — | X | — |
STROMWANDLER | — | — | X | — |
SPANNUNGSWANDLER | — | — | X | — |
DATENLOGGER | — | — | X | — |
KOMMUNIKATIONSANSCHLUSS | — | — | X | — |
MODEM | — | — | X | — |
TELEKOMMUNIKATIONSEINRICHTUNG | — | — | X | — |
KOMMUNIKATIONSEINRICHTUNG | — | — | X | — |
DREHKOLBENGASZAEHLER | — | — | X | — |
TURBINENRADGASZAEHLER | — | — | X | — |
ULTRASCHALLZAEHLER | — | — | X | — |
WIRBELGASZAEHLER | — | — | X | — |
MODERNE_MESSEINRICHTUNG | — | — | X | — |
ELEKTRONISCHER_HAUSHALTSZAEHLER | — | — | X | — |
STEUEREINRICHTUNG | — | — | X | — |
TECHNISCHESTEUEREINRICHTUNG | — | — | X | — |
TARIFSCHALTGERAET | — | — | X | — |
RUNDSTEUEREMPFAENGER | — | — | X | — |
OPTIONALE_ZUS_ZAEHLEINRICHTUNG | — | — | X | — |
MESSWANDLERSATZ_IMS_MME | — | — | X | — |
KOMBIMESSWANDLER_IMS_MME | — | — | X | — |
TARIFSCHALTGERAET_IMS_MME | — | — | X | — |
RUNDSTEUEREMPFAENGER_IMS_MME | — | — | X | — |
TEMPERATUR_KOMPENSATION | — | — | X | — |
HOECHSTBELASTUNGS_ANZEIGER | — | — | X | — |
SONSTIGES_GERAET | — | — | X | — |
SMARTMETERGATEWAY | — | — | X | — |
STEUERBOX | — | — | X | — |
BLOCKSTROMWANDLER | — | — | X | — |
KOMBIMESSWANDLER | — | — | X | — |
MODEM_GSM | — | — | X | — |
ETHERNET_KOM | — | — | X | — |
PLC_COM | — | — | X | — |
MODEM_FESTNETZ | — | — | X | — |
DSL_KOM | — | — | X | — |
LTE_KOM | — | — | X | — |
DICHTEMENGENUMWERTER | — | — | X | — |
TEMPERATURMENGENUMWERTER | — | — | X | — |
ZUSTANDSMENGENUMWERTER | — | — | X | — |
MESSDATENREGISTRIERGERAET | — | — | X | — |
WANDLER | — | — | X | — |
BEFESTIGUNGSEINRICHTUNG | — | — | X | — |
| weitereGeraetenummern 01920 | weitereGeraetenummern | array | X | — |
| geraeteeigenschaften | — | object | May | — |
| faktor 01930 | faktor | number (float) | Must | — |
| geraetemerkmal 01940 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlwerke [ ] | — | object[] | May | — |
| konfiguration 01950 | Configuration (iMSys) of the meter register | string | X | — |
| nachkommastelle 01960 | nachkommastelle | integer | Must | — |
| obisKennzahl 01970 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| vorkommastelle 01980 | vorkommastelle | integer | Must | — |
| wertegranularitaet 01990 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer * 02000 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| antwortstatus * 02010 | Response status / STS+E01 | string | X | — |
| antwortstatusCodeliste * 02020 | Response status code list / STS+E01 | string | X | — |
| datumleistungsbeginn * 02030 | Date of the planned start of service / DTM+76 | string (date-time) | X | — |
| dokumentennummer * 02040 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| kategorie * 02050 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 02060 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 02070 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 02080 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 02090 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vorgangsnummer * 02100 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 02110 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 02120 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 02130 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 02140 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55043 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0100070 | Registrations | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/ message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00160 | Message recipient | — | X | — |
303900170 | MP-ID | — | X | — |
3055 900180 | GS1 | — | X | — |
3055 29300190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400200 | Transaction | — | X | — |
740200210 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 7600220 | Delivery date/time, scheduled | — | X | — |
238000230 | Date or time or time span, value | — | X | [UB1] |
2379 30300240 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700250 | Transaction reason | — | X | — |
9013 E0100260 | Move-in/move-out (relocation) | — | X | — |
9013 E0200270 | Move-in to creation | — | X | — |
9013 E0300280 | Change | — | X | — |
9013 ZJ400290 | Takeover due to iMS installation not carried out | — | X | — |
| SG4.STS | — | — | Must | [249] |
9015 E0100300 | Status of the response | — | X | — |
901300310 | Code of the check step | — | X | — |
1131 S_005500320 | Electricity code list no. S_0055 | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1800330 | Grid location | — | X | — |
322500340 | ID of the grid location | — | X | [960] |
| SG5.LOC | — | — | Must | — |
3227 Z1600350 | Market location | — | X | — |
322500360 | ID of the market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2200370 | Dormant market location | — | X | — |
322500380 | ID of the dormant market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2000390 | Technical resource | — | X | — |
322500400 | ID of the technical resource | — | X | [922] |
| SG5.LOC | — | — | Must | — |
3227 Z1900410 | Controllable resource | — | X | — |
322500420 | ID of the controllable resource | — | X | [961] |
| SG5.LOC | — | — | Must | — |
3227 Z2100430 | Tranche | — | X | — |
322500440 | ID of the tranche | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z1700450 | Metering location | — | X | — |
322500460 | ID of the metering location | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300470 | Check identifier | — | X | — |
1154 5504300480 | WiM electricity / confirmation of registration MSB | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00490 | Transaction reference number | — | X | — |
115400500 | Transaction number | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 Z5000510 | Scheduling data of the market location | — | X | — |
115400520 | ID of the market location / reference to time period ID | — | X | [950] |
| SG6.DTM | — | — | Must | [78] ∧ [234] ∧ [618] |
2005 75200530 | Periodic meter reading | — | X | — |
238000540 | Date or time or time span, value | — | X | — |
2379 10400550 | MMWW-MMWW | — | X | — |
2379 10600560 | MMDD | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z7800570 | Reference to the location bundle structure | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3100580 | Location bundle structure | — | X | — |
1153 Z3900590 | No standardized location bundle structure available | — | X | — |
115400600 | ID of the location bundle structure | — | X | [333] |
115600610 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.SEQ | — | — | Must | — |
1229 Z5800620 | Assignment of the location to the object code of the location bundle | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200630 | Grid location | — | X | — |
1153 Z1800640 | Market location | — | X | — |
1153 Z1900650 | Metering location | — | X | — |
1153 Z3700660 | Technical resource | — | X | — |
115400670 | ID of a location | — | X | ([451] ∧ [950]) ⊻ ([452] ∧ [951]) ⊻ ([450] ∧ [960]) ⊻ ([456] ∧ [922]) |
| SG8.RFF | — | — | Must | [2312] |
1153 Z3300680 | Object code of the location in the location bundle structure | — | X | — |
115400690 | Object code | — | X | — |
115600700 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.RFF | — | — | Must | ([176] ∧ (([173] ∧ [179]) ⊻ ([174] ∧ [175]))) ⊻ ([177] ∧ [178] ∧ [179]) |
1153 Z3400710 | upstream metering location | — | X | — |
1153 Z3500720 | upstream grid location | — | X | — |
115400730 | ID of a location | — | X | ([442] ∧ [951]) ⊻ ([440] ∧ [960]) |
| SG8.RFF | — | — | Must | [179] ∧ [291] |
1153 Z1600740 | assigned market location | — | X | — |
115400750 | ID of the market location | — | X | [950] |
| SG8.SEQ | — | — | Must | — |
1229 Z5100760 | Data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200770 | Grid location | — | X | — |
115400780 | ID of the grid location | — | X | [960] |
| SG10.CCI | — | — | Must | — |
7059 Z4900790 | Control channel | — | X | — |
7037 ZF200800 | No control channel available | — | X | — |
7037 ZF300810 | Control channel present | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB300820 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9100830 | MSB | — | X | — |
113100840 | MP-ID | — | X | — |
7110 Z3900850 | Default metering point operator | — | X | — |
7110 Z4000860 | Competitive metering point operator | — | X | — |
7110 Z4100870 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z5700880 | OBIS data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200890 | Grid location | — | X | — |
115400900 | ID of the grid location | — | X | [960] |
| SG8.PIA | — | — | Must | [159] |
4347 500910 | Product identification | — | X | — |
714000920 | OBIS code of the grid location | — | X | — |
7143 SRW00930 | OBIS code | — | X | — |
714300940 | Purpose of use NB | — | X | [353] |
1131 Z1600950 | EDI@Energy code list of purposes of use | — | X | — |
714300960 | Purpose of use LF | — | X | [354] |
1131 Z1600970 | EDI@Energy code list of purposes of use | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1100980 | Product | — | X | — |
7037 ZF600990 | No product assigned | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z6001000 | Product data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3201010 | Grid location | — | X | — |
115401020 | ID of a grid location | — | X | [960] |
| SG8.PIA | — | — | Must | — |
4347 501030 | Product identification | — | X | — |
714001040 | Configuration product code | — | X | [412] |
7143 Z1201050 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5301060 | Code of the power curve definition | — | X | — |
703701070 | Code of the power curve definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB301080 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8801090 | NB | — | X | — |
7111 Z8901100 | LF | — | X | — |
113101110 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA701120 | LF | — | X | [1P0..1] |
7037 ZA801130 | NB | — | X | [1P0..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z0101140 | Data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801150 | Market location | — | X | — |
115401160 | ID of the market location | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 26501170 | Estimated annual quantity total/ annual consumption forecast for specific energy for day-parameter-dependent market location | — | X | — |
6063 Z0801180 | Adjusted electrical energy in accordance with Annex D of the VDN guideline "Load profiles for interruptible consumption devices" | — | X | — |
606001190 | Quantity | — | X | [902] |
6411 Z1601200 | kWh/K (kilowatt hour/Kelvin) | — | X | [103] |
6411 KWH01210 | Kilowatt hour | — | X | [104] |
| SG9.QTY | — | — | Must | — |
6063 3101220 | Estimated annual quantity total | — | X | — |
606001230 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH01240 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3001250 | Delivery direction | — | X | — |
7037 Z0601260 | Generation | — | X | — |
7037 Z0701270 | Consumption | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB301280 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | [78] ∧ [221] |
7111 Z8901290 | LF | — | X | — |
113101300 | MP-ID | — | X | [611] |
| SG10.CAV | — | — | Must | — |
7111 Z9001310 | ÜNB | — | X | — |
113101320 | MP-ID | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9101330 | MSB | — | X | — |
113101340 | MP-ID | — | X | [621] |
7110 Z3901350 | Default metering point operator | — | X | — |
7110 Z4001360 | Competitive metering point operator | — | X | — |
7110 Z4101370 | Fallback metering point operator | — | X | — |
7110 Z1901380 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2001390 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0301400 | Voltage level of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0301410 | Extra-high voltage | — | X | — |
7111 E0401420 | High voltage | — | X | — |
7111 E0501430 | Medium voltage | — | X | — |
7111 E0601440 | Low voltage | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z8301450 | Metering classification of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z5201460 | iMS | — | X | — |
7111 Z5301470 | kME / mME | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 601480 | Responsible party | — | X | — |
7037 ZA801490 | NB | — | X | — |
7037 ZA901500 | ÜNB | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZC001510 | Forecast based on values | — | X | — |
7037 ZA601520 | Forecast based on profiles | — | X | — |
| SG10.CAV | — | — | Must | [210] ∧ ([2182] ⊻ ([90] ∧ [2183])) |
7111 E0201530 | SLP/SEP | — | X | [1P0..1] |
7111 E1401540 | TLP/TEP | — | X | [1P0..1] |
7111 Z3601550 | TEP with reference measurement | — | X | [1P0..1] |
| SG10.CCI | — | — | Must | — |
7037 Z3401560 | Type of the generating market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3301570 | EEG market location without DV obligation | — | X | — |
7111 Z3401580 | KWKG market location without DV obligation | — | X | — |
7111 Z3501590 | other market location | — | X | — |
7111 Z3701600 | EEG market location with DV obligation | — | X | — |
7111 Z4601610 | KWKG market location with DV obligation | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 ZA201620 | Processing model | — | X | — |
7037 ZE901630 | Model 1 "Balancing at the market location" | — | X | — |
7037 ZF001640 | Model 2 "Balancing in the balancing area (BG) of the LPB" | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2701650 | Required metering product of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801660 | Market location | — | X | — |
115401670 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 501680 | Product identification | — | X | — |
714001690 | Metering product code | — | X | [425] |
7143 Z1101700 | Product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3901710 | Code of the metering time period definition | — | X | — |
7059 Z4101720 | No metering time period required for metering product | — | X | [417] |
703701730 | Code of the metering time period definition | — | X | [438] |
| SG10.CCI | — | — | Must | — |
7037 ZA801740 | NB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8401750 | Grid usage settlement | — | X | [19P1..1] ⊻ [20P1..1] ⊻ [22P1..1] ⊻ [26P1..1] |
7111 Z8501760 | Balancing group settlemen t | — | X | [21P0..1] ⊻ [22P0..1] ⊻ [23P0..1] ⊻ [24P0..1] |
7111 Z8601770 | Excess/shortfall quantity settlement | — | X | [20P1..1] ⊻ [27P1..1] |
7111 Z9201780 | Transmission to the HKNR | — | X | [23P1..1] ⊻ [24P1..1] |
7111 ZE101790 | There is no purpose of use | — | X | [38P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA701800 | LF | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8401810 | Grid usage settlement | — | X | [19P0..1] ⊻ [20P0..1] ⊻ [22P0..1] ⊻ [26P0..1] |
7111 Z8501820 | Balancing group settlemen t | — | X | [21P1..1] ⊻ [22P1..1] ⊻ [23P1..1] ⊻ [24P1..1] |
7111 Z8601830 | Excess/shortfall quantity settlement | — | X | [20P1..1] ⊻ [27P1..1] |
7111 Z4701840 | End customer billing | — | X | [19P1..1] ⊻ [20P0..1] ⊻ [22P1..1] ⊻ [24P1..1] ⊻ [25P1..1] ⊻ [26P0..1] ⊻ [27P1..1] |
7111 ZE101850 | There is no purpose of use | — | X | [38P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA901860 | ÜNB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8501870 | Balancing group settlemen t | — | X | [1P0..1] |
7111 ZB501880 | For the determination of the balance of balancing groups | — | X | [1P1..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z0201890 | OBIS data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801900 | Market location | — | X | — |
115401910 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 501920 | Product identification | — | X | — |
714001930 | OBIS code of the market location | — | X | [314] |
7143 SRW01940 | OBIS code | — | X | — |
714301950 | Purpose of use NB | — | X | [381] |
1131 Z1601960 | EDI@Energy code list of purposes of use | — | X | — |
714301970 | Purpose of use LF | — | X | [382] |
1131 Z1601980 | EDI@Energy code list of purposes of use | — | X | — |
714301990 | Purpose of use ÜNB | — | X | [383] |
1131 Z1602000 | EDI@Energy code list of purposes of use | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE402010 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD902020 | Annually | — | X | — |
7111 ZE802030 | Semi-annual | — | X | — |
7111 ZE902040 | Quarterly | — | X | — |
7111 ZB702050 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3902060 | Code of the metering time period definition | — | X | — |
703702070 | Code of the metering time period definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3802080 | Code of the metering time period register | — | X | — |
703702090 | Code of the metering time period register | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1502100 | Data of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2002110 | Tranche | — | X | — |
115402120 | ID of the tranche | — | X | [950] |
| SG8.RFF | — | — | Must | — |
1153 Z1602130 | assigned market location | — | X | — |
115402140 | ID of the market location | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 1102150 | Distribution quantity | — | X | — |
606002160 | Quantity specification in % | — | X | [914] ∧ [930] ∧ [955] |
6411 P102170 | Percent | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB302180 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8902190 | LF | — | X | — |
113102200 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3702210 | Basis for determining the tranche size | — | X | — |
7037 ZD102220 | Percentage-based | — | X | — |
7037 ZD202230 | Distribution factor based on reference carrier/ installed capacity | — | X | — |
7037 ZH102240 | Distribution across technical resources | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1602250 | Required product of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2002260 | Tranche | — | X | — |
115402270 | ID of a tranche | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 502280 | Product identification | — | X | — |
714002290 | Metering product code | — | X | [426] |
7143 Z1102300 | Product | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA802310 | NB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8502320 | Balancing group settlemen t | — | X | [1P0..1] |
7111 Z9202330 | Transmission to the HKNR | — | X | [1P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA702340 | LF | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8502350 | Balancing group settlemen t | — | X | [1P1..1] |
7111 Z4702360 | End customer billing | — | X | [1P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA902370 | ÜNB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8502380 | Balancing group settlemen t | — | X | [1P0..1] |
7111 ZB502390 | For the determination of the balance of balancing groups | — | X | [1P1..1] |
| SG10.CAV | — | — | Must | [446] |
| SG8.SEQ | — | — | Must | — |
1229 Z5202400 | Data of the technical resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3702410 | Technical resource | — | X | — |
115402420 | ID of the technical resource | — | X | [922] |
| SG8.RFF | — | — | Should | [166] ∧ [699] |
1153 Z3802430 | Controllable resource | — | X | — |
115402440 | ID of the controllable resource | — | X | [961] |
| SG8.RFF | — | — | Should | [166] ∧ [700] |
1153 Z3202450 | Grid location | — | X | — |
115402460 | ID of the grid location | — | X | [960] |
| SG8.RFF | — | — | Should | [166] ∧ [447] ∧ [701] |
1153 Z2002470 | Tranche | — | X | — |
115402480 | ID of the tranche | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 Z4302490 | Rated power (input) | — | X | — |
606002500 | Quantity | — | X | — |
6411 KWT02510 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4402520 | Rated power (output) | — | X | — |
606002530 | Quantity | — | X | — |
6411 KWT02540 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4202550 | Storage capacity | — | X | — |
606002560 | Quantity | — | X | — |
6411 KWH02570 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1702580 | Type of electricity consumption | — | X | — |
7059 Z5002590 | Type of electricity generation | — | X | — |
7059 Z5602600 | Storage | — | X | — |
| SG10.CAV | — | — | Must | [446] |
7111 Z6402610 | Power/light | — | X | [1P0..1] |
7111 Z6502620 | Heat/cold | — | X | [1P0..1] |
7111 ZE502630 | E-mobility | — | X | [1P0..1] |
7111 ZA802640 | Street lighting | — | X | [1P0..1] |
| SG10.CAV | — | — | Must | [239] |
7111 Z5602650 | Storage heating | — | X | — |
7111 Z5702660 | Heat pump (unspecified) | — | X | — |
7111 Z6102670 | Direct heating | — | X | — |
7111 ZV502680 | Heat pump (heat and cold) | — | X | — |
7111 ZV602690 | Heat pump (cold) | — | X | — |
7111 ZV702700 | Heat pump (heat) | — | X | — |
| SG10.CAV | — | — | Must | [95] |
7111 ZE602710 | Wallbox | — | X | — |
7111 Z8702720 | E-mobility charging station | — | X | — |
7111 ZE702730 | Charging park | — | X | — |
| SG10.CAV | — | — | Must | [447] |
7111 ZF502740 | Solar | — | X | — |
7111 ZF602750 | Wind | — | X | — |
7111 ZG002760 | Gas | — | X | — |
7111 ZG102770 | Water | — | X | — |
7111 ZG502780 | Other generation type | — | X | — |
| SG10.CAV | — | — | Must | [448] |
7111 ZF702790 | Hydrogen storage | — | X | — |
7111 ZF802800 | Pumped storage | — | X | — |
7111 ZF902810 | Battery storage | — | X | — |
7111 ZG602820 | Other storage type | — | X | — |
| SG10.CAV | — | — | Must | [446] ⊻ [448] |
7111 ZG802830 | Technical resource is covered by § 14a EnWG | — | X | — |
7111 ZG902840 | Technical resource is not covered by § 14a EnWG | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z6202850 | Data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3802860 | Controllable resource | — | X | — |
115402870 | ID of the controllable resource | — | X | [961] |
| SG10.CCI | — | — | Must | — |
7059 Z4902880 | Control channel | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF202890 | Service description of the control channel | — | X | — |
1131 Z1402900 | On/Off | — | X | — |
1131 Z1502910 | Tiered | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB302920 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9102930 | MSB | — | X | — |
113102940 | MP-ID | — | X | — |
7110 Z3902950 | Default metering point operator | — | X | — |
7110 Z4002960 | Competitive metering point operator | — | X | — |
7110 Z4102970 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z6102980 | Product data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3802990 | Controllable resource | — | X | — |
115403000 | ID of a controllable resource | — | X | [961] |
| SG8.PIA | — | — | Must | [81] |
4347 503010 | Product identification | — | X | — |
714003020 | Configuration product code | — | X | — |
7143 Z1203030 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1103040 | Product | — | X | — |
7037 ZF603050 | No product assigned | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5203060 | Code of the switching time definition | — | X | — |
7059 Z5303070 | Code of the power curve definition | — | X | — |
703703080 | Code of the definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB303090 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8803100 | NB | — | X | — |
7111 Z8903110 | LF | — | X | — |
113103120 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA803130 | NB | — | X | [1P0..1] |
7037 ZA703140 | LF | — | X | [1P0..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z1803150 | Data of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1903160 | Metering location | — | X | — |
115403170 | ID of the metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 ZB303180 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9103190 | MSB | — | X | — |
113103200 | MP-ID | — | X | [621] |
7110 Z3903210 | Default metering point operator | — | X | — |
7110 Z4003220 | Competitive metering point operator | — | X | — |
7110 Z4103230 | Fallback metering point operator | — | X | — |
7110 Z1903240 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2003250 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF003260 | gMSB | — | X | — |
113103270 | MP-ID | — | X | — |
| SG10.CAV | — | — | Must | [78] ∧ [184] |
7111 ZB403280 | MSBA | — | X | — |
113103290 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0403300 | Voltage level of the metering location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0303310 | Extra-high voltage | — | X | — |
7111 E0403320 | High voltage | — | X | — |
7111 E0503330 | Medium voltage | — | X | — |
7111 E0603340 | Low voltage | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0103350 | Scope of use | — | X | — |
7037 Z8203360 | ID of the metering location handled in the process | — | X | [2236] |
7037 Z8103370 | ID of the metering location in the location bundle | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3203380 | Operating state of the metering location | — | X | — |
7037 ZC103390 | Metering location blocked and may not be unblocked | — | X | — |
7037 ZC203400 | Metering location blocked and may be unblocked | — | X | — |
7037 ZC303410 | Metering location in regular operation | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1903420 | Required product of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1903430 | Metering location | — | X | — |
115403440 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Must | [429] |
1153 Z1803450 | Market location | — | X | — |
115403460 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 503470 | Product identification | — | X | — |
714003480 | Metering product code | — | X | [427] |
7143 Z1103490 | Product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3503500 | Description required value | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZC903510 | Second measurement required for comparative measurement | — | X | — |
7110 Z0603520 | present | — | X | — |
7110 Z0703530 | not present | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8803540 | NB | — | X | — |
7110 Z0603550 | present | — | X | — |
7110 Z0703560 | not present | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3903570 | Code of the metering time period definition | — | X | — |
7059 Z4103580 | No metering time period required for metering product | — | X | [417] |
703703590 | Code of the metering time period definition | — | X | [438] |
| SG8.SEQ | — | — | Must | — |
1229 Z0303600 | Metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1903610 | Metering location | — | X | — |
115403620 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Should | [166] ∧ [215] |
1153 Z1403630 | Smart meter gateway | — | X | — |
115403640 | Identification / number of the smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1303650 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AHZ03660 | analog household meter (three-phase current) | — | X | — |
7111 WSZ03670 | analog alternating current meter | — | X | — |
7111 LAZ03680 | Load curve meter | — | X | — |
7111 MAZ03690 | Maximum demand meter | — | X | — |
7111 MME03700 | modern metering device according to MsbG | — | X | — |
7111 EHZ03710 | electronic household meter | — | X | — |
7111 IVA03720 | Individual reconciliation (special equipment) | — | X | — |
7110 Z0103730 | EDL40 | — | X | [136] |
7110 Z0203740 | EDL21 | — | X | [136] |
7110 Z0303750 | other EHZ | — | X | [136] |
7110 Z0403760 | Standard | — | X | [346] |
7110 Z0503770 | MeDa meter | — | X | [346] |
| SG10.CAV | — | — | Must | — |
7111 Z3003780 | Device number | — | X | — |
711003790 | Device number | — | X | — |
| SG10.CAV | — | — | Must | [139] |
7111 ETZ03800 | Single tariff | — | X | — |
7111 ZTZ03810 | Two-tariff | — | X | — |
7111 NTZ03820 | Multi-tariff | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ERZ03830 | Single-direction meter | — | X | — |
7111 ZRZ03840 | Bidirectional meter | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z5803850 | Remote switching of the metering device | — | X | — |
7110 Z0603860 | present | — | X | — |
7110 Z0703870 | not present | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2803880 | Mounting type metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 BKE03890 | Plug-in technology (mounting and contacting device) | — | X | — |
7111 DPA03900 | 3- Three-point suspension | — | X | — |
7111 HUT03910 | DIN rail | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1203920 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR03930 | remotely readable meters | — | X | — |
7111 MMR03940 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2003950 | OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [78] ∧ [665] |
1153 MG03960 | Device number of the meter | — | X | [441] |
1153 Z1403970 | Smart meter gateway | — | X | — |
115403980 | Device number | — | X | — |
| SG8.RFF | — | — | Must | [78] |
1153 Z1903990 | Metering location | — | X | — |
115404000 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Must | [78] ∧ [402] ∧ [420] ∧ [651] |
1153 Z1804010 | Market location | — | X | — |
115404020 | ID of a market location | — | X | [950] |
| SG8.RFF | — | — | Must | [402] ∧ [420] |
1153 AGK04030 | Application reference number | — | X | — |
115404040 | Reference, identification | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 504050 | Product identification | — | X | — |
714004060 | OBIS code of the metering device | — | X | [323] |
7143 SRW04070 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE404080 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD904090 | Annually | — | X | — |
7111 ZE804100 | Semi-annual | — | X | — |
7111 ZE904110 | Quarterly | — | X | — |
7111 ZB704120 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1104130 | Product | — | X | — |
7037 Z3304140 | Integer and decimal places of the register | — | X | — |
| SG10.CAV | — | — | Must | — |
711004150 | Digits before the decimal point | — | X | — |
711004160 | Digits after the decimal point | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0404170 | Instrument transformer data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG04180 | Device number of the meter | — | X | — |
115404190 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2504200 | Instrument transformer | — | X | — |
| SG10.CAV | — | — | Must | [2317] ⊻ [2318] |
7111 Z3004210 | Device number | — | X | — |
711004220 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 MIW04230 | Current transformer set | — | X | — |
7111 MPW04240 | Combined instrument transformer set (current and voltage) | — | X | — |
7111 MBW04250 | Block current transformer | — | X | — |
7111 MUW04260 | Voltage transformer set | — | X | — |
711004270 | Instrument transformer factor | — | X | [902] [141] |
| SG8.SEQ | — | — | Must | — |
1229 Z0504280 | Communication device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG04290 | Device number of the meter | — | X | — |
115404300 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2604310 | Communication device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004320 | Device number | — | X | — |
711004330 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 GSM04340 | GSM/GPRS/UMTS- comm. dev. | — | X | — |
7111 ETH04350 | Ethernet comm. dev. LAN/WLAN | — | X | — |
7111 PLC04360 | PLC comm. device | — | X | — |
7111 PST04370 | Landline comm. dev. TAE | — | X | — |
7111 DSL04380 | DSL comm. dev. | — | X | — |
7111 LTE04390 | LTE comm. dev. | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0604400 | Data of the technical control device | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG04410 | Device number of the meter | — | X | — |
115404420 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2704430 | Technical control device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004440 | Device number | — | X | — |
711004450 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 RSU04460 | Ripple control receiver | — | X | — |
7111 TSU04470 | Tariff time switch | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1304480 | Smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7504490 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004500 | Device number | — | X | — |
711004510 | Device number | — | X | [952] |
| SG8.SEQ | — | — | Must | — |
1229 Z1404520 | Control box | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1404530 | Smart meter gateway | — | X | — |
115404540 | Identification / number of the smart meter gateway | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1804550 | Market location | — | X | — |
115404560 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7037 Z7604570 | Control box | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004580 | Device number | — | X | — |
711004590 | Device number | — | X | [952] |
| SG8.SEQ | — | — | Must | — |
1229 Z2104600 | Profile data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1804610 | Market location | — | X | — |
115404620 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7059 Z0204630 | Standard load profile | — | X | — |
7059 Z0404640 | Standard feed-in profile | — | X | — |
7037 E0104650 | synthetic method | — | X | — |
7037 Z1004660 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711104670 | Code of the standardized profile | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0804680 | Profile set data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1804690 | Market location | — | X | — |
115404700 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7059 Z0304710 | day-parameter-dependent load profile | — | X | — |
7059 Z0504720 | day-parameter-dependent feed-in profile | — | X | — |
7037 E0104730 | synthetic method | — | X | — |
7037 Z1004740 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711104750 | Code of the standardized profile | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z9904760 | Measuring station of the daily parameter (currently only the temperature is a permitted daily parameter) | — | X | — |
7059 ZA004770 | Climate zone of the daily parameter (currently is daily parameter) | — | X | — |
703704780 | ID of climate zone / temperature measuring point | — | X | — |
113104790 | Service provider | — | X | [58] |
3055 8904800 | Assigned by the trader (here grid operator) | — | X | — |
3055 29304810 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z3804820 | Reference profile data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1804830 | Market location | — | X | — |
115404840 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7059 Z0504850 | day-parameter-dependent feed-in profile | — | X | — |
| SG10.CAV | — | — | Must | — |
711104860 | Code of the reference profile | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0904870 | Customer of the LF | — | X | — |
303604880 | Name | — | X | — |
3045 Z0104890 | Structure of person names | — | X | — |
3045 Z0204900 | Structure of the company name | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1804910 | Market location | — | X | — |
115404920 | ID of the market location | — | X | [950] |
| SG12.NAD | — | — | Must | — |
3035 Z0404930 | Correspondence address of the customer of the LF | — | X | — |
303604940 | Name | — | X | — |
3045 Z0104950 | Structure of person names | — | X | — |
3045 Z0204960 | Structure of the company name | — | X | — |
304204970 | Street and house number or PO box | — | X | — |
316404980 | City | — | X | — |
325104990 | Postal code | — | — | M [268] S [166] |
320705000 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1805010 | Market location | — | X | — |
115405020 | ID of the market location | — | X | [950] |
| SG12.NAD | — | — | Must | — |
3035 Z0705030 | Customer of the MSB | — | X | — |
303605040 | Name | — | X | — |
3045 Z0105050 | Structure of person names | — | X | — |
3045 Z0205060 | Structure of the company name | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1905070 | Metering location | — | X | — |
115405080 | ID of the metering location | — | X | [951] |
| SG12.NAD | — | — | Must | — |
3035 Z0805090 | Correspondence address of the customer of the MSB | — | X | — |
303605100 | Name | — | X | — |
3045 Z0105110 | Structure of person names | — | X | — |
3045 Z0205120 | Structure of the company name | — | X | — |
304205130 | Street and house number or PO box | — | X | — |
316405140 | City | — | X | — |
325105150 | Postal code | — | — | M [268] S [166] |
320705160 | Country name, code | — | X | — |
| SG13.CTA | — | — | Must | — |
3139 IC05170 | Information contact | — | X | — |
| SG13.COM | — | — | Must | — |
314805180 | Number / address | — | X | — |
3155 TE05190 | Telephone | — | X | [1P0..1] |
3155 EM05200 | Electronic mail | — | X | [1P0..1] |
| SG12.NAD | — | — | Must | — |
3035 Z0305210 | Metering location address | — | X | — |
312405220 | Additional information for identification | — | — | — |
304205230 | Street and house number or PO box | — | — | S [166] M [212] |
316405240 | City | — | X | — |
325105250 | Postal code | — | X | — |
320705260 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1905270 | Metering location | — | X | — |
115405280 | ID of a metering location | — | X | [951] |
| SG12.NAD | — | — | Must | — |
3035 Z0505290 | Name and address for the meter reading card | — | X | — |
303605300 | Name | — | X | — |
3045 Z0105310 | Structure of person names | — | X | — |
3045 Z0205320 | Structure of the company name | — | X | — |
304205330 | Street and house number or PO box | — | X | — |
316405340 | City | — | X | — |
325105350 | Postal code | — | — | M [268] S [166] |
320705360 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1905370 | Metering location | — | X | — |
115405380 | ID of a metering location | — | X | [951] |
| UNT | — | — | Must | — |
007405390 | Number of segments in a message | — | X | — |
006205400 | Message reference number | — | X | — |
Conditions of this table
The free text of the 105 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [32] | If more than one SG8 (reference to the location bundle structure) is present |
| [58] | If in this CCI the DE3055 with the code 293 is present |
| [78] | If SG4 STS+7++E02 (transaction reason: move-in to creation) is not present |
| [81] | If in the same SG8 SEQ+Z61/ZB3/ZB4 (product data of the controllable resource) the SG10 CCI+11 (details on the product of the controllable resource) is not present |
| [90] | If SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) present once with CAV+E14 (TLP/TEP) and once with CAV+E02 (SLP/SEP) in this SG8 |
| [95] | If in the same SG10 the CCI+Z17 (type of electricity consumption ) CAV+ZE5 (e-mobility) is present |
| [103] | If SG9 QTY+265 (energy / power for day-parameter-dependent market location: estimated annual quantity total) present in this SG8 |
| [104] | If SG9 QTY+Z08 (energy / power for day-parameter-dependent market location: adjusted electrical energy according to Annex D) present in this SG8 |
| [136] | If SG10 CCI+++E13 (meter type) CAV+EHZ (electronic household meter) present in this SG8 |
| [139] | If SG10 CAV+IVA (individual reconciliation) not present in this SG8 |
| [141] | If SG10 CAV+MIW/MPW/MBW present |
| [159] | If in the same SG8 SEQ+Z57 (OBIS data of the grid location) the SG10 CCI+11 (OBIS data of the grid location) is not present |
| [166] | If present |
| [173] | If DE1156 (consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is not present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [174] | If DE1156 consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [175] | If the object code in RFF+Z33 (reference to the object code in the location bundle struct ure) in DE1154 of the same SG8 SEQ+Z58 (assignment of location to the object code of the location bundle) is present in a further SG8 SEQ+Z58 with the same sequential number |
| [176] | If DE1153 with code Z34 upstream metering location is present in the same segment |
| [177] | If DE1153 with code Z35 upstream grid location is present in the same segment |
| [178] | If the LOC+Z18 (grid location) is present |
| [179] | If the object code in RFF+Z33 (reference to the object code in the location bundle struc ture) in DE1154 of the same SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle ) is present in a further SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle ) with an identical code in DE1229 |
| [184] | If in the same SG8 SEQ+Z18 (data of the metering location) a CCI+Z01++Z82 (scope of use: ID of the metering location handled in the process) is present |
| [210] | If SG10 CCI+++ZA6 (forecast based on profiles) present in this SG8 |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [215] | If in the same SG8 (metering device data) SG10 CCI+++E13 CAV+MME (meter type: mME) is present |
| [221] | If no SG8 SEQ+Z15 (data of the tranche) references the same market location ID with the RFF+Z18 (market location) as this SG8 SEQ+Z01 (data of the market location) |
| [234] | If SG10 CCI+++Z83 (metering classification of the market location) CAV+Z53 (kME/mME) is present |
| [239] | If in the same SG10 the CCI+Z17 (type of electricity consumption ) is present in the CAV+Z65 (heat/cooling) |
| [249] | Within one SG4 IDE, all DE1131 of the SG4 STS+E01 (status of the response) must contain the identical value |
| [268] | If an "X" is listed for the code in DE3207 in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| [291] | If in the same SG8 (assignment of location to the object code of the location bundle ) the RFF+Z37 is present |
| [314] | All OBIS codes in accordance with the code list of OBIS codes and media, chapter 3, that are required at the market location must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document Code list of configurations |
| [323] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3., that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document "Code list of configurations" |
| [333] | If in this RFF "reference to the location bundle structure" the code Z31 "location bundle structure" is present in DE1153 |
| [346] | If SG10 CCI+++E13 (meter type) CAV+MME (mME) present in this SG8 |
| [353] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/NeLo“ column and in the „Usable for market role/NB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [354] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/NeLo“ column and in the „Usable for market role/LF“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [381] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/NB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [382] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/LF“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [383] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/ÜNB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [402] | If in the same SG8 (OBIS data of the metering device / smart meter gateway) an OBIS code of the value type "meter reading" is present in the PIA+5 |
| [412] | Only configuration product codes from the "EDI@Energy code list of configurations", chapter 4.2 Configuration products power curve definition, are permitted |
| [417] | If no metering time period is required for the required value |
| [420] | If the RFF+Z14 (smart meter gateway) is present in this SG8 |
| [425] | Metering product code from chapter 2.1 "Standard metering products of the market location" of the code list of configurations |
| [426] | Metering product code from chapter 2.2 "Standard metering products of the tranche" of the code list of configurations |
| [427] | Metering product code from chapter 2.3 "Standard metering products of the metering location" of the code list of configurations |
| [429] | If in the same SG8 SEQ+Z19/ZF4 (required metering product of the metering location) the PIA+5 DE7140 with a metering product from the code list of configurations chapter 2.3.1 standard metering product of the metering location with the option of assigning a |
| [438] | If code Z39 (code of the metering time period) is present in DE7059 in the same CCI |
| [440] | If code Z35 (upstream grid location) is present in DE1153 in the same RFF |
| [441] | If RFF+Z14 (reference to the smart meter gateway) is not present in the SG8+SEQ+Z03/ZF5 (metering device data) for the device number of a meter named in this RFF DE1154 |
| [442] | If code Z34 (upstream metering location) is present in DE1153 in the same RFF |
| [446] | If in the same SG8 the CCI+Z17 (type of electricity consumption ) is present |
| [447] | If in the same SG8 the CCI+Z50 (type of electricity generation ) is present |
| [448] | If in the same SG8 the CCI+Z56 (storage) is present |
| [450] | If code Z32 (grid location) is present in DE1153 in the same RFF |
| [451] | If code Z18 (market location) is present in DE1153 in the same RFF |
| [452] | If code Z19 (metering location) is present in DE1153 in the same RFF |
| [456] | If code Z37 (technical resource) is present in DE1153 in the same RFF |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [611] | Note: If the company NB performs the tasks of the market role LF, the MP-ID of the company NB in the market role LF is to be stated |
| [618] | Note: Previous date of the MSBA. If the MSBN wishes to use a different date, it communicates the new date by means of a master data change |
| [621] | Note: The MSB must be specified that is assigned to the location from the point in time named in DTM+76 (date of the planned start of supply). |
| [651] | Note: The market locations for which the OBIS named here is required must be specified |
| [665] | Note: If a meter is parameterized with a SMGW, no OBIS code numbers are stated for that meter. Only OBIS code numbers from the SMGW exist here |
| [699] | Note: The ID of the controllable resource via which the technical resource is controlled must be specified |
| [700] | Note: The ID of the grid location via which the technical resource is controlled must be specified |
| [701] | Note: The Malo ID of the tranche to which the technical resource is assigned must be specified |
| [902] | Format: Possible value: ≥ 0 |
| [914] | Format: Possible value: > 0 |
| [922] | Format: TR-ID |
| [930] | Format: max. 2 decimal places |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [955] | Format: Possible value: < 100 |
| [960] | Format: Grid location ID |
| [961] | Format: SR-ID |
| [2182] | Segment group must be specified exactly once per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2183] | Segment group must be specified exactly twice per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2236] | Code once per SG4 IDE+24 (transaction) |
| [2312] | If the object code "9992000001256" (grid location) is not present in DE1154 of the same RFF+Z33, the RFF+Z33 must be specified exactly once in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle ) |
| [2317] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MIW/MPW/MUW is present, the segment must be specified at least twice |
| [2318] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MBW (block current transformer ) is present, the segment must be specified exactly once |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [19P1..1] | [20] If in the SG8 SEQ+Z01 (data of the market location) with the same ID in SG8 RFF+Z18 (reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) is present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of configurations chapter 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 30 ] If another SG8 SEQ+Z27 (Required metering product of the market location), which with the RFF+Z18 (reference to the ID of the market location) references the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [20P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 31 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [22P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [26P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [4 30 ] If another SG8 SEQ+Z27 (Required metering product the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 ( for active energy load curve 1/4-hourly) is present [436] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000086 :Z11 (active energy highest 1/4 hour in the month) is present |
| [21P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [22P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [23P0..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [24P0..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [27P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 31 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [23P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [24P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [38P1..1] | [419] If no other package in this SG10 in the same SG8 SEQ leads to the possibility of specifying at least one other code in this data element |
| [19P0..1] | [20] If in the SG8 SEQ+Z01 (data of the market location) with the same ID in SG8 RFF+Z18 (reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) is present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of configurations chapter 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 30 ] If another SG8 SEQ+Z27 (Required metering product of the market location), which with the RFF+Z18 (reference to the ID of the market location) references the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [20P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 31 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [26P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [4 30 ] If another SG8 SEQ+Z27 (Required metering product the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 ( for active energy load curve 1/4-hourly) is present [436] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000086 :Z11 (active energy highest 1/4 hour in the month) is present |
| [21P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [25P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 30 ] If another SG8 SEQ+Z27 (Required metering product the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 ( for active energy load curve 1/4-hourly) is present |
| [1P1..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
UNA:+.? '
UNB+UNOC:3+9900496000001:500+9900496000002:500+{{date}}:{{time}}+M3CJAXK5'
UNH+UNHM33TKB5W+UTILMD:D:11A:UN:S2.2'
BGM+E01+BGMM2F84HWH'
DTM+137:202610021100?+00:303'
NAD+MS+9900496000001::293'
NAD+MR+9900496000002::293'
IDE+24+KBG27094210000000000929931413171000'
DTM+76:202612052300?+00:303'
STS+7++E02'
STS+E01++E15:S_0055'
LOC+Z16+50363191616'
LOC+Z17+DE0032106765712000000000000001717'
RFF+Z13:55043'
RFF+TN:NV12372'
RFF+Z50:50363191616'
SEQ+Z78'
RFF+Z31:9992000000026'
SEQ+Z58'
RFF+Z18:50363191616'
RFF+Z33:9992000001016'
SEQ+Z58'
RFF+Z19:DE0032106765712000000000000001717'
RFF+Z33:9992000001032'
SEQ+Z01'
RFF+Z18:50363191616'
CCI+Z30++Z07'
CCI+++ZB3'
CAV+Z90:9900496003333'
CAV+Z91:9900496000002::Z39:Z19'
CCI+++E03'
CAV+E04'
CCI+++Z83'
CAV+Z52'
CCI+6++ZA8'
CCI+++ZC0'
CCI+ZA2++ZE9'
SEQ+Z27'
RFF+Z18:50363191616'
PIA+5+9991000000078:Z11'
CCI+++ZA8'
CAV+Z84'
CCI+++ZA7'
CAV+Z84'
CCI+++ZA9'
CAV+Z85'
SEQ+Z18'
RFF+Z19:DE0032106765712000000000000001717'
CCI+++ZB3'
CAV+Z91:9900496000002::Z39:Z19'
CAV+ZF0:9900496000022'
CCI+++E04'
CAV+E03'
CCI+Z01++Z82'
CCI+Z32++ZC1'
SEQ+Z19'
RFF+Z19:DE0032106765712000000000000001717'
PIA+5+9991000000218:Z11'
CCI+Z35'
CAV+ZC9:::Z06'
CAV+Z88:::Z06'
NAD+Z07+++Hans:Muller::::Z01'
RFF+Z19:DE0032106765712000000000000001717'
NAD+Z08+++Jan:Schoeler::::Z01+Schönhauser Allee::36+Berlin++10435+DE'
CTA+IC'
COM+max@mustermann.de:EM'
NAD+Z03++Hinter:Hof++Erfurter str.::46+Weimar++99423+DE'
RFF+Z19:DE0032106765712000000000000001717'
NAD+Z05+++Max:Mustermann::::Z01+Erfurter str.::46+Weimar++99423+DE'
RFF+Z19:DE0032106765712000000000000001717'
UNT+69+UNHM33TKB5W'
UNZ+1+M3CJAXK5'[1 item
{6 fields
"data": {3 fields
"stammdaten": {6 fields
"MARKTLOKATION": [1 item
{10 fields
"marktlokationsTyp": [1 item
{1 field
"marktrollen": [2 items
{6 fields
{8 fields
"zaehlwerke": [1 item
{2 fields
"verwendungszwecke": [3 items
{2 fields
"zweck": [1 item
{2 fields
"zweck": [1 item
{2 fields
"zweck": [1 item
"MESSLOKATION": [1 item
{12 fields
"messadresse": {6 fields
"zusatzInformation": {2 fields
"zaehlwerke": [1 item
{4 fields
"zaehlzeiten": {1 field
"ablesekartenempfaenger": {7 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {5 fields
"marktrollen": [2 items
{8 fields
{6 fields
"LOKATIONSBUENDEL": [1 item
{5 fields
"zuordnungObjectcode": [2 items
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
"NETZNUTZUNGSVERTRAG": [1 item
{6 fields
"MESSSTELLENBETRIEBSVERTRAG": [1 item
{8 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"korrespondenzpartner": {7 fields
"partneradresse": {5 fields
"ansprechpartner": {3 fields
"BILANZIERUNG": [1 item
{6 fields
"transaktionsdaten": {15 fields
"absender": {4 fields
"empfaenger": {4 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Start of metering point operation | WiM electricity part 1 | Electricity | Step 2 |
| NB | NB | Start of metering point operation | WiM electricity part 1 | Electricity | Step 2 |
| MSB | MSBA | Start of metering point operation | WiM electricity part 1 | Electricity | Step 2 |
| MSB | MSBN | Start of metering point operation | WiM electricity part 1 | Electricity | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Confirmation of registration MSB |
| AHB | UTILMD AHB electricity |
| Decision tree | E_0201 |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 1 | Start of metering point operation | NB → MSBN | Response to registration |
Transaction and responses
Role of this check identifier: response — confirmation. Basis: the transaction data carry antwortstatus and antwortstatusCodeliste; the title or the action of the Prüfi table begins with “response”; the title names a polarity (confirmation).
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 55042 | Registration MSB | UTILMD | from the step sequence |
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfragereferenznummer | SG4.IDE+24.SG6.RFF+TN | vorgangsnummer |
For RFF+TN, the time slice field description gives »reference transaction number (from request message)« — the target is the vorgangsnummer in segment SG4.IDE+24 of the request. Measured: 55042 lists vorgangsnummer in SG4.IDE+24.
Response codes
Decision trees: S_0055 · E_0201.
The Prüfi table names one further tree across all rows of this check identifier. They tie it to a process, not to a row of its handbook — their codes are therefore only on the respective tree page. For S_0055 there is no decision tree in version 202610; its response codes are therefore not given here.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 756 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type utilmd. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.