Check identifier 55065 — Supplier clearing list
Check identifier 55065 · EDIFACT message type UTILMD · Format version 202604
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55065 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.100060 | Version number of the underlying BDEW message description | — | X | — |
006800070 | General assignment reference | — | — | S [1] |
007000080 | Transmission sequence number | — | — | M [252] |
0073 C00090 | Start | — | — | M [2] |
0073 F00100 | End | — | — | S [3] |
| BGM | — | — | Must | — |
1001 Z0500110 | Clearing list | — | X | — |
100400120 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700130 | Document-/message date/time | — | X | — |
238000140 | Date or time or time span, value | — | X | [931] [494] |
2379 30300150 | CCYYMMDDHHMMZZZ | — | X | — |
| DTM | — | — | Must | — |
2005 15700160 | Validity, start date | — | X | — |
238000170 | Date or time or time span, value | — | X | — |
2379 61000180 | CCYYMM | — | X | — |
| SG1.RFF | — | — | Must | — |
1153 AAV00190 | Number of the request | — | X | — |
115400200 | Reference, identification | — | X | [503] |
| SG2.NAD | — | — | Must | — |
3035 MS00210 | Document-/message sender or sender | — | X | — |
303900220 | MP-ID | — | X | — |
3055 900230 | GS1 | — | X | — |
3055 29300240 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00250 | Information contact | — | X | — |
341200260 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800270 | Number / address | — | X | (([939] [321]) ∨ ([940] [322])) ∧ [514] |
3155 EM00280 | Electronic mail | — | X | [1P0..1] |
3155 FX00290 | Fax number | — | X | [1P0..1] |
3155 TE00300 | Telephone | — | X | [1P0..1] |
3155 AJ00310 | further telephone | — | X | [1P0..1] |
3155 AL00320 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00330 | Message recipient | — | X | — |
303900340 | MP-ID | — | X | [280] |
3055 900350 | GS1 | — | X | — |
3055 29300360 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | [564] |
7495 Z0100370 | List | — | X | — |
740200380 | List number | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1500390 | MaBiS metering point | — | X | — |
322500400 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300410 | Check identifier | — | X | — |
1154 5506500420 | MaBiS / Supplier clearing list | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2200430 | Data of the aggregated time series | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 AUU00440 | Reference to a time series | — | X | — |
115400450 | Version of the time series | — | X | — |
| SG4.IDE | — | — | Must | [565] |
7495 2400460 | Transaction | — | X | — |
740200470 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 15800480 | Start of balancing | — | X | — |
238000490 | Date or time or time span, value | — | X | [UB1] |
2379 30300500 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.DTM | — | — | Should | [14] |
2005 15900510 | End of balancing | — | X | — |
238000520 | Date or time or time span, value | — | X | [UB1] |
2379 30300530 | CCYYMMDDHHMMZZZ | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1600540 | Market location | — | X | — |
322500550 | ID of the market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2100560 | Tranche | — | X | — |
322500570 | ID of the tranche | — | X | [950] |
| SG8.SEQ | — | — | Must | — |
1229 Z0100580 | Data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1800590 | Market location | — | X | — |
115400600 | ID of the market location | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 Z1000610 | Power of the market location | — | X | — |
6063 26500620 | Estimated annual quantity total/annual consumption forecast for specific energy for day-parameter-dependent market location | — | X | — |
6063 Z0800630 | Adjusted electrical energy in accordance with Annex D of the VDN guideline "Load profiles for interruptible consumption devices" | — | X | — |
606000640 | Quantity | — | X | [902] |
6411 Z1600650 | kWh/K (kilowatt hour/Kelvin) | — | X | [103] |
6411 KWH00660 | Kilowatt hour | — | X | [104] |
6411 KWT00670 | Kilowatt | — | X | [105] |
| SG9.QTY | — | — | Must | — |
6063 3100680 | Estimated annual quantity total | — | X | — |
606000690 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH00700 | Kilowatt hour | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z0700710 | Actually balanced energy quantity | — | X | — |
606000720 | Quantity specification | — | X | [902] |
6411 KWH00730 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1800740 | Control area | — | X | — |
703700750 | Control area | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1900760 | Balancing group | — | X | — |
703700770 | Balancing group | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2000780 | Balancing area | — | X | — |
703700790 | Balancing area | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1500800 | Structure | — | X | — |
7037 Z2100810 | Aggregated time series type | — | X | — |
| SG10.CAV | — | — | Must | — |
711100820 | Code of the time series type | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1500830 | Data of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2000840 | Tranche | — | X | — |
115400850 | ID of the tranche | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 Z0700860 | Actually balanced energy quantity | — | X | — |
606000870 | Quantity specification | — | X | [902] |
6411 KWH00880 | Kilowatt hour | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2100890 | Profile data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1200900 | Reference to a profile | — | X | — |
115400910 | Version of the profile | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1800920 | Market location | — | X | — |
115400930 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7059 Z0200940 | Standard load profile | — | X | — |
7059 Z0400950 | Standard feed-in profile | — | X | — |
7037 E0100960 | synthetic method | — | X | — |
7037 Z1000970 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711100980 | Code of the standardized profile | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0800990 | Profile set data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1201000 | Reference to a profile | — | X | — |
115401010 | Version of the profile | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801020 | Market location | — | X | — |
115401030 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7059 Z0301040 | day-parameter-dependent load profile | — | X | — |
7059 Z0501050 | day-parameter-dependent feed-in profile | — | X | — |
7037 E0101060 | synthetic method | — | X | — |
7037 Z1001070 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711101080 | Code of the standardized profile | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z3801090 | Reference profile data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1201100 | Reference to a profile | — | X | — |
115401110 | Version of the profile | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801120 | Market location | — | X | — |
115401130 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7059 Z0501140 | day-parameter-dependent feed-in profile | — | X | — |
| SG10.CAV | — | — | Must | — |
711101150 | Code of the reference profile | — | X | — |
| UNT | — | — | Must | — |
007401160 | Number of segments in a message | — | X | — |
006201170 | Message reference number | — | X | — |
Conditions of this table
The free text of the 25 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [1] | If a split is present |
| [2] | If UNH DE0070 (transmission sequence number) with 1 is present |
| [3] | In the case of splitting, in the message with the highest transmission sequence number |
| [14] | If the date is known |
| [103] | If SG9 QTY+265 (energy / power for day-parameter-dependent market location: estimated annual quantity total) present in this SG8 |
| [104] | If SG9 QTY+Z08 (energy / power for day-parameter-dependent market location: adjusted electrical energy according to Annex D) present in this SG8 |
| [105] | If SG9 QTY+Z10 (energy / power for day-parameter-dependent market location: power of the market location) present in this SG8 |
| [252] | If DE0068 is present |
| [280] | Only MP-ID from the electricity division |
| [321] | If code EM is present in DE3155 in the same COM |
| [322] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [503] | Note: Indication of BGM DE1004 from the ORDERS |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [564] | Note: The IDE+Z01 (list) defines the business transaction. All listed IDE+24 are part of the business transaction |
| [565] | Note: The IDE+24 describes a component of a list if a IDE+Z01 is present. It does not describe the business transaction |
| [902] | Format: Possible value: ≥ 0 |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and ÜNB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Exchange of the supplier clearing list between NB and LF (incl. subscription) | MaBiS | Electricity | Step 2 |
| LF | LF | Exchange of the supplier clearing list between ÜNB and LF (incl. subscription) | MaBiS | Electricity | Step 2 |
| NB | NB | Exchange of the supplier clearing list between NB and LF (incl. subscription) | MaBiS | Electricity | Step 2 |
| ÜNB | ÜNB | Exchange of the supplier clearing list between ÜNB and LF (incl. subscription) | MaBiS | Electricity | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Supplier clearing list |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Exchange of the supplier clearing list between NB and LF (incl. subscription) | NB → LF | Transmission of the LF-CL |
| MaBiS | Exchange of the supplier clearing list between ÜNB and LF (incl. subscription) | ÜNB → LF | Transmission of the LF-CL |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 165 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.