Check identifier 55095 — Response to GDA generating MaLo
Check identifier 55095 · EDIFACT message type UTILMD · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 55095 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| BILANZIERUNG [ ] * | — | object[] | Must | — |
| detailsPrognosegrundlage 00010 | Forecast basis - If a day-parameter-dependent load profile with joint metering has to be specified, this is possible by repeating the CAV segment twice, stating the codes E02 and E14. | array | Must | — |
| prognosegrundlage * 00020 | Forecast basis | Enum Prognosegrundlage | Must | — |
WERTE | — | — | Must | — |
PROFILE | — | — | Must | — |
| jahresverbrauchsprognose | — | object | May | — |
| einheit 00030 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 00040 | Value | number (float) | X | — |
| lastprofile [ ] | — | object[] | May | — |
| bezeichnung 00050 | Designation of the profile | string | Must | — |
| einspeisung 00060 | Feed-in indicator | boolean | X | — |
| profilart 00070 | Profile category | Enum Profilart | X | — |
ART_STANDARDLASTPROFIL | — | — | X | — |
ART_TAGESPARAMETERABHAENGIGES_LASTPROFIL | — | — | X | — |
ART_LASTPROFIL | — | — | X | — |
| profilschar 00080 | Profile set of the profile | string | Must | — |
| referenzprofilbezeichnung 00090 | Designation of the reference profile | string | Must | — |
| verfahren 00100 | Profiling method | Enum Profilverfahren | X | — |
SYNTHETISCH | — | — | X | — |
ANALYTISCH | — | — | X | — |
| tagesparameter | — | object | May | — |
| dienstanbieter 00110 | dienstanbieter | string | Must | — |
| herausgeber 00120 | Herausgeber | Enum Herausgeber | Must | — |
NB | — | — | Must | — |
BDEW | — | — | Must | — |
TUM | — | — | Must | — |
| klimazone 00130 | klimazone | string | Must | — |
| temperaturmessstelle 00140 | temperaturmessstelle | string | Must | — |
| temperaturarbeit | — | object | May | — |
| einheit 00150 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | Must | — |
W | — | — | Must | — |
WH | — | — | Must | — |
KW | — | — | Must | — |
KWH | — | — | Must | — |
KVARH | — | — | Must | — |
MW | — | — | Must | — |
MWH | — | — | Must | — |
STUECK | — | — | Must | — |
KUBIKMETER | — | — | Must | — |
STUNDE | — | — | Must | — |
TAG | — | — | Must | — |
MONAT | — | — | Must | — |
JAHR | — | — | Must | — |
PROZENT | — | — | Must | — |
ANZAHL | — | — | Must | — |
VAR | — | — | Must | — |
KVAR | — | — | Must | — |
VARH | — | — | Must | — |
KWHK | — | — | Must | — |
Z16 | — | — | Must | — |
KWT | — | — | Must | — |
WATT_PRO_QUADRATMETER | — | — | Must | — |
METER_PRO_SEKUNDE | — | — | Must | — |
| wert 00160 | Value | number (float) | Must | — |
| LOKATIONSBUENDEL [ ] * | — | object[] | Must | — |
| lokationsbuendelNummer 00170 | lokationsbuendelNummer | integer | Must | — |
| lokationsbuendelstrukturId 00180 | lokationsbuendelstrukturId | string | Must | — |
| standardisierteLokationsbuendelstruktur * 00190 | standardisierteLokationsbuendelstruktur | boolean | Must | — |
| zuordnungObjectcode [ ] | — | object[] | May | — |
| referenzLokationsId 00200 | referenzLokationsId | string | Must | — |
| referenzLokationsTyp 00210 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| referenzMarktlokationTechnischeRessource 00220 | referenzMarktlokationTechnischeRessource | array | X | — |
| vorgelagerteLokationId 00230 | vorgelagerteLokationId | string | Must | — |
| vorgelagerteLokationTyp 00240 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| objectcode [ ] | — | object[] | May | — |
| lokationsbuendelNummer 00250 | lokationsbuendelNummer | integer | X | — |
| objectcode 00260 | objectcode | string | X | — |
| MARKTLOKATION [ ] * | — | object[] | Must | — |
| konfigurationsprodukt 00270 | konfigurationsprodukt | string | X | — |
| leistungskurvendefinition 00280 | Code of the assigned power curve definition for the object | string | X | — |
| marktlokationsId * 00290 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| messtechnischeEinordnung * 00300 | Metering classification from the UTILMD (IMS, KME_MME, KEINE_MESSUNG) | Enum MesstechnischeEinordnung | Must | — |
IMS | — | — | Must | — |
KME_MME | — | — | Must | — |
KEINE_MESSUNG | — | — | Must | — |
| netzebene * 00310 | Grid level at which the energy is drawn. For electricity, the voltage level of the supply; for gas, the pressure level. Example electricity: low voltage Example gas: low pressure. | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| redispatch 00320 | redispatch | boolean | X | — |
| energieherkunft [ ] * | — | object[] | Must | — |
| erzeugungsart * 00330 | Type of generation | Enum Erzeugungsart | Must | — |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| lokationsadresse | — | object | May | — |
| hausnummer 00340 | House number and supplement | string | X | — |
| landescode 00350 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00360 | City | string | X | — |
| ortsteil 00370 | District | string | X | — |
| postfach 00380 | PO box | string | X | — |
| postleitzahl 00390 | Postal code | string | X | — |
| strasse 00400 | Street | string | X | — |
| zusatzInformation | — | object | May | — |
| zusatz1 00410 | Address supplement 1 | string | X | — |
| zusatz2 00420 | Address supplement 2 | string | X | — |
| zusatz3 00430 | Address supplement 3 | string | X | — |
| zusatz4 00440 | Address supplement 4 | string | X | — |
| zusatz5 00450 | Address supplement 5 | string | X | — |
| marktrollen [ ] * | — | object[] | Must | — |
| marktrolle 00460 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft * 00470 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer * 00480 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet * 00490 | weiterverpflichtet | boolean | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| obisKennzahl 00500 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| wertegranularitaet 00510 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| messlokationsId * 00520 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00530 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00540 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00550 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00560 | weiterverpflichtet | boolean | X | — |
| NETZLOKATION [ ] | — | object[] | May | — |
| konfigurationsprodukt 00570 | konfigurationsprodukt | string | X | — |
| leistungskurvendefinition 00580 | Code of the assigned power curve definition for the object | string | X | — |
| netzlokationsId 00590 | Identification number of a grid location at which energy is either consumed or generated (like MarktlokationsId market location) | string | X | — |
| steuerkanal 00600 | Whether a control channel is assigned to the grid location and the grid location can therefore be controlled. ZF2: No control channel present ZF3: Control channel present | boolean | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00610 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00620 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00630 | Specifies the code value of the market role. | string | X | — |
| STEUERBARE_RESSOURCE [ ] | — | object[] | May | — |
| konfigurationsprodukt 00640 | konfigurationsprodukt | string | X | — |
| ressourcenId 00650 | ressourcenId | string | X | — |
| steuerkanal 00660 | Control channel | Enum Steuerkanal | X | — |
AN_AUS | — | — | X | — |
GESTUFT | — | — | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00670 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00680 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00690 | Specifies the code value of the market role. | string | X | — |
| zugeordneteDefinition | — | object | May | — |
| leistungskurvendefinition 00700 | leistungskurvendefinition | string | Must | — |
| schaltzeitdefinition 00710 | schaltzeitdefinition | string | Must | — |
| TECHNISCHE_RESSOURCE [ ] | — | object[] | May | — |
| art 00720 | Technical resource type | Enum TechnischeRessourceArt | Must | — |
STROMERZEUGUNG | — | — | Must | — |
STROMVERBRAUCH | — | — | Must | — |
SPEICHER | — | — | Must | — |
| erzeugungsart 00730 | Type of energy generation. Details generation type Example: CAV+ZF5' Generation type: ZF5: solar ZF6: wind ZG0: gas ZG1: water ZG5: other generation type | Enum Erzeugungsart | Must | — |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| referenzNetzlokation 00740 | referenzNetzlokation | string | X | — |
| referenzSteuerbareRessource 00750 | referenzSteuerbareRessource | string | X | — |
| ressourcenId 00760 | ressourcenId | string | X | — |
| speicherart 00770 | Type of storage. Details storage type Example: CAV+ZF7' Storage type: ZF7: hydrogen storage ZF8: pumped storage ZF9: battery storage ZG6: other storage type | Enum Speicherart | Must | — |
WASSERSTOFFSPEICHER | — | — | Must | — |
PUMPSPEICHER | — | — | Must | — |
BATTERIESPEICHER | — | — | Must | — |
SONSTIGE_SPEICHERART | — | — | Must | — |
| speicherkapazitaet 00780 | Storage capacity Example: QTY+Z42:100:KWH' | number (float) | X | — |
| nennleistung | — | object | May | — |
| abgabe 00790 | Submission of the rated capacity | number (float) | X | — |
| aufnahme 00800 | Recording of the rated power | number (float) | X | — |
| TRANCHE [ ] | — | object[] | May | — |
| tranchenId 00810 | tranchenId | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| obisKennzahl 00820 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| ZAEHLER [ ] | — | object[] | May | — |
| gateway 00830 | Specification of a SMGW with which the meter is parameterised | string | X | — |
| messlokationsId 00840 | messlokationsId | string | X | — |
| messwerterfassung 00850 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| zaehlernummer 00860 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 00870 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 00880 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 00890 | The number printed on the device, which is assigned by the MSB. | string | Must | — |
| geraetetyp 00900 | List of possible billable device types | Enum Geraetetyp | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
ZWEIRICHTUNGSZAEHLER | — | — | Must | — |
RLM_ZAEHLER | — | — | Must | — |
IMS_ZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
MULTIPLEXANLAGE | — | — | Must | — |
PAUSCHALANLAGE | — | — | Must | — |
VERSTAERKERANLAGE | — | — | Must | — |
SUMMATIONSGERAET | — | — | Must | — |
IMPULSGEBER | — | — | Must | — |
EDL_21_ZAEHLERAUFSATZ | — | — | Must | — |
VIER_QUADRANTEN_LASTGANGZAEHLER | — | — | Must | — |
MENGENUMWERTER | — | — | Must | — |
STROMWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
DATENLOGGER | — | — | Must | — |
KOMMUNIKATIONSANSCHLUSS | — | — | Must | — |
MODEM | — | — | Must | — |
TELEKOMMUNIKATIONSEINRICHTUNG | — | — | Must | — |
KOMMUNIKATIONSEINRICHTUNG | — | — | Must | — |
DREHKOLBENGASZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MODERNE_MESSEINRICHTUNG | — | — | Must | — |
ELEKTRONISCHER_HAUSHALTSZAEHLER | — | — | Must | — |
STEUEREINRICHTUNG | — | — | Must | — |
TECHNISCHESTEUEREINRICHTUNG | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
OPTIONALE_ZUS_ZAEHLEINRICHTUNG | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER_IMS_MME | — | — | Must | — |
TARIFSCHALTGERAET_IMS_MME | — | — | Must | — |
RUNDSTEUEREMPFAENGER_IMS_MME | — | — | Must | — |
TEMPERATUR_KOMPENSATION | — | — | Must | — |
HOECHSTBELASTUNGS_ANZEIGER | — | — | Must | — |
SONSTIGES_GERAET | — | — | Must | — |
SMARTMETERGATEWAY | — | — | Must | — |
STEUERBOX | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
PLC_COM | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
WANDLER | — | — | Must | — |
BEFESTIGUNGSEINRICHTUNG | — | — | Must | — |
| zaehlwerke [ ] | — | object[] | May | — |
| konfiguration 00910 | Configuration (iMSys) of the meter register | string | X | — |
| obisKennzahl 00920 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| wertegranularitaet 00930 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer * 00940 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| dokumentennummer * 00950 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| kategorie * 00960 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 00970 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00980 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00990 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 01000 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vorgangsnummer * 01010 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 01020 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 01030 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 01040 | Email address | string | Must | — |
| nachname 01050 | Surname (family name) of the contact person | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 01060 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 01070 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 01080 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 01090 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55095 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E4400070 | Information notification | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00160 | Information contact | — | X | — |
341200170 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800180 | Number / address | — | X | (([939] [321]) ∨ ([940] [322])) ∧ [514] |
3155 EM00190 | Electronic mail | — | X | [1P0..1] |
3155 FX00200 | Fax number | — | X | [1P0..1] |
3155 TE00210 | Telephone | — | X | [1P0..1] |
3155 AJ00220 | further telephone | — | X | [1P0..1] |
3155 AL00230 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00240 | Message recipient | — | X | — |
303900250 | MP-ID | — | X | — |
3055 900260 | GS1 | — | X | — |
3055 29300270 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400280 | Transaction | — | X | — |
740200290 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700300 | Transaction reason | — | X | — |
9013 ZY600310 | Response to GDA generating MaLo | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1800320 | Grid location | — | X | — |
322500330 | ID of the grid location | — | X | [960] |
| SG5.LOC | — | — | Must | — |
3227 Z1600340 | Market location | — | X | — |
322500350 | ID of the market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2000360 | Technical resource | — | X | — |
322500370 | ID of the technical resource | — | X | [922] |
| SG5.LOC | — | — | Must | — |
3227 Z1900380 | Controllable resource | — | X | — |
322500390 | ID of the controllable resource | — | X | [961] |
| SG5.LOC | — | — | Must | — |
3227 Z2100400 | Tranche | — | X | — |
322500410 | ID of the tranche | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z1700420 | Metering location | — | X | — |
322500430 | ID of the metering location | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300440 | Check identifier | — | X | — |
1154 5509500450 | GPKE / Response to GDA for generating MaLo | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 AAV00460 | Number of the request | — | X | — |
115400470 | Transaction number | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZD500480 | Informative reference to the location bundle structure | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3100490 | Location bundle structure | — | X | — |
1153 Z3900500 | No standardized location bundle structure available | — | X | — |
115400510 | ID of the location bundle structure | — | X | [333] |
115600520 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.SEQ | — | — | Must | — |
1229 ZD600530 | Informative assignment of location to the object code of the location bundle | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200540 | Grid location | — | X | — |
1153 Z1800550 | Market location | — | X | — |
1153 Z1900560 | Metering location | — | X | — |
1153 Z3700570 | Technical resource | — | X | — |
115400580 | ID of a location | — | X | ([451] ∧ [950]) ⊻ ([452] ∧ [951]) ⊻ ([450] ∧ [960]) ⊻ ([456] ∧ [922]) |
| SG8.RFF | — | — | Must | [2313] |
1153 Z3300590 | Object code of the location in the location bundle structure | — | X | — |
115400600 | Object code | — | X | — |
115600610 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.RFF | — | — | Must | ([176] ∧ (([173] ∧ [179]) ⊻ ([174] ∧ [175]))) ⊻ ([177] ∧ [178] ∧ [179]) |
1153 Z3400620 | upstream metering location | — | X | — |
1153 Z3500630 | upstream grid location | — | X | — |
115400640 | ID of a location | — | X | ([442] ∧ [951]) ⊻ ([440] ∧ [960]) |
| SG8.RFF | — | — | Must | [179] ∧ [291] |
1153 Z1600650 | assigned market location | — | X | — |
115400660 | ID of the market location | — | X | [950] |
| SG8.SEQ | — | — | Must | — |
1229 ZD700670 | Informative data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200680 | Grid location | — | X | — |
115400690 | ID of the grid location | — | X | [960] |
| SG10.CCI | — | — | Must | — |
7059 Z4900700 | Control channel | — | X | — |
7037 ZF200710 | No control channel available | — | X | — |
7037 ZF300720 | Control channel present | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB300730 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9100740 | MSB | — | X | — |
113100750 | MP-ID | — | X | — |
7110 Z3900760 | Default metering point operator | — | X | — |
7110 Z4000770 | Competitive metering point operator | — | X | — |
7110 Z4100780 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE000790 | Informative product data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200800 | Grid location | — | X | — |
115400810 | ID of a grid location | — | X | [960] |
| SG8.PIA | — | — | Must | — |
4347 500820 | Product identification | — | X | — |
714000830 | Configuration product code | — | X | [412] |
7143 Z1200840 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5300850 | Code of the power curve definition | — | X | — |
703700860 | Code of the power curve definition | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z9800870 | Informative data of the market location | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z1000880 | Power of the market location | — | X | [102] |
6063 26500890 | Estimated annual quantity total/annual consumption forecast for specific energy for day-parameter-dependent market location | — | X | — |
6063 Z0800900 | Adjusted electrical energy in accordance with Annex D of the VDN guideline "Load profiles for interruptible consumption devices" | — | X | — |
606000910 | Quantity | — | X | [902] |
6411 Z1600920 | kWh/K (kilowatt hour/Kelvin) | — | X | [103] |
6411 KWH00930 | Kilowatt hour | — | X | [104] |
6411 KWT00940 | Kilowatt | — | X | [105] |
| SG9.QTY | — | — | Must | — |
6063 3100950 | Estimated annual quantity total | — | X | — |
606000960 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH00970 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB300980 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9000990 | ÜNB | — | X | — |
113101000 | MP-ID | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9101010 | MSB | — | X | — |
113101020 | MP-ID | — | X | — |
7110 Z3901030 | Default metering point operator | — | X | — |
7110 Z4001040 | Competitive metering point operator | — | X | — |
7110 Z4101050 | Fallback metering point operator | — | X | — |
7110 Z1901060 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2001070 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0301080 | Voltage level of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0301090 | Extra-high voltage | — | X | — |
7111 E0401100 | High voltage | — | X | — |
7111 E0501110 | Medium voltage | — | X | — |
7111 E0601120 | Low voltage | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z8301130 | Metering classification of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z5201140 | iMS | — | X | — |
7111 Z5301150 | kME / mME | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZC001160 | Forecast based on values | — | X | — |
7037 ZA601170 | Forecast based on profiles | — | X | — |
| SG10.CAV | — | — | Must | [21] ∧ [2061] |
7111 E0201180 | SLP/SEP | — | X | [1P0..1] |
7111 E1401190 | TLP/TEP | — | X | [1P0..1] |
7111 Z3601200 | TEP with reference measurement | — | X | [1P0..1] |
| SG10.CCI | — | — | Must | — |
7037 Z3401210 | Type of the generating market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3301220 | EEG market location without DV obligation | — | X | — |
7111 Z3401230 | KWKG market location without DV obligation | — | X | — |
7111 Z3501240 | other market location | — | X | — |
7111 Z3701250 | EEG market location with DV obligation | — | X | — |
7111 Z4601260 | KWKG market location with DV obligation | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE301270 | Informative OBIS data of the market location | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 501280 | Product identification | — | X | — |
714001290 | OBIS code of the market location | — | X | [314] |
7143 SRW01300 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401310 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD901320 | Annually | — | X | — |
7111 ZE801330 | Semi-annual | — | X | — |
7111 ZE901340 | Quarterly | — | X | — |
7111 ZB701350 | Monthly | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE401360 | Informative product data of the market location | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 501370 | Product identification | — | X | — |
714001380 | Product/service number | — | X | — |
7143 Z1201390 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5301400 | Code of the power curve definition | — | X | — |
703701410 | Code of the definition | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE601420 | Informative product data of the market location of the NB | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 501430 | Product identification | — | X | — |
7140 AUA01440 | Curtailed energy | — | X | — |
7143 Z0801450 | Medium | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE701460 | Informative data of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2001470 | Tranche | — | X | — |
115401480 | ID of the tranche | — | X | [950] |
| SG8.SEQ | — | — | Must | — |
1229 ZE901490 | Informative OBIS data of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2001500 | Tranche | — | X | — |
115401510 | ID of a tranche | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 501520 | Product identification | — | X | — |
714001530 | OBIS code of the tranche | — | X | [269] |
7143 SRW01540 | OBIS code | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF001550 | Informative data of the technical resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3701560 | Technical resource | — | X | — |
115401570 | ID of the technical resource | — | X | [922] |
| SG8.RFF | — | — | Should | [166] ∧ [699] |
1153 Z3801580 | Controllable resource | — | X | — |
115401590 | ID of the controllable resource | — | X | [961] |
| SG8.RFF | — | — | Should | [166] ∧ [700] |
1153 Z3201600 | Grid location | — | X | — |
115401610 | ID of the grid location | — | X | [960] |
| SG9.QTY | — | — | Must | — |
6063 Z4301620 | Rated power (input) | — | X | — |
606001630 | Quantity | — | X | — |
6411 KWT01640 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4401650 | Rated power (output) | — | X | — |
606001660 | Quantity | — | X | — |
6411 KWT01670 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4201680 | Storage capacity | — | X | — |
606001690 | Quantity | — | X | — |
6411 KWH01700 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1701710 | Type of electricity consumption | — | X | — |
7059 Z5001720 | Type of electricity generation | — | X | — |
7059 Z5601730 | Storage | — | X | — |
| SG10.CAV | — | — | Must | [447] |
7111 ZF501740 | Solar | — | X | — |
7111 ZF601750 | Wind | — | X | — |
7111 ZG001760 | Gas | — | X | — |
7111 ZG101770 | Water | — | X | — |
7111 ZG501780 | Other generation type | — | X | — |
| SG10.CAV | — | — | Must | [448] |
7111 ZF701790 | Hydrogen storage | — | X | — |
7111 ZF801800 | Pumped storage | — | X | — |
7111 ZF901810 | Battery storage | — | X | — |
7111 ZG601820 | Other storage type | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF101830 | Informative data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3801840 | Controllable resource | — | X | — |
115401850 | ID of the controllable resource | — | X | [961] |
| SG10.CCI | — | — | Must | — |
7059 Z4901860 | Control channel | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF201870 | Service description of the control channel | — | X | — |
1131 Z1401880 | On/Off | — | X | — |
1131 Z1501890 | Tiered | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB301900 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9101910 | MSB | — | X | — |
113101920 | MP-ID | — | X | — |
7110 Z3901930 | Default metering point operator | — | X | — |
7110 Z4001940 | Competitive metering point operator | — | X | — |
7110 Z4101950 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF201960 | Informative product data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3801970 | Controllable resource | — | X | — |
115401980 | ID of a controllable resource | — | X | [961] |
| SG8.PIA | — | — | Must | — |
4347 501990 | Product identification | — | X | — |
714002000 | Configuration product code | — | X | — |
7143 Z1202010 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5202020 | Code of the switching time definition | — | X | — |
7059 Z5302030 | Code of the power curve definition | — | X | — |
703702040 | Code of the definition | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF302050 | Informative data of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1902060 | Metering location | — | X | — |
115402070 | ID of the metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 ZB302080 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9102090 | MSB | — | X | — |
113102100 | MP-ID | — | X | — |
7110 Z3902110 | Default metering point operator | — | X | — |
7110 Z4002120 | Competitive metering point operator | — | X | — |
7110 Z4102130 | Fallback metering point operator | — | X | — |
7110 Z1902140 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2002150 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF002160 | gMSB | — | X | — |
113102170 | MP-ID | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF502180 | Informative metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1902190 | Metering location | — | X | — |
115402200 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Should | [166] ∧ [215] |
1153 Z1402210 | Smart meter gateway | — | X | — |
115402220 | Identification / number of the smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1302230 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AHZ02240 | analog household meter (three-phase current) | — | X | — |
7111 WSZ02250 | analog alternating current meter | — | X | — |
7111 LAZ02260 | Load curve meter | — | X | — |
7111 MAZ02270 | Maximum demand meter | — | X | — |
7111 MME02280 | modern metering device according to MsbG | — | X | — |
7111 EHZ02290 | electronic household meter | — | X | — |
7111 IVA02300 | Individual reconciliation (special equipment) | — | X | — |
7110 Z0102310 | EDL40 | — | X | [136] |
7110 Z0202320 | EDL21 | — | X | [136] |
7110 Z0302330 | other EHZ | — | X | [136] |
7110 Z0402340 | Standard | — | X | [346] |
7110 Z0502350 | MeDa meter | — | X | [346] |
| SG10.CAV | — | — | Must | — |
7111 Z3002360 | Device number | — | X | — |
711002370 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1202380 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR02390 | remotely readable meters | — | X | — |
7111 MMR02400 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF602410 | Informative OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [665] |
1153 MG02420 | Device number of the meter | — | X | [441] |
1153 Z1402430 | Smart meter gateway | — | X | — |
115402440 | Device number | — | X | — |
| SG8.RFF | — | — | Must | [402] ∧ [420] |
1153 AGK02450 | Application reference number | — | X | — |
115402460 | Reference, identification | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 502470 | Product identification | — | X | — |
714002480 | OBIS code of the metering device | — | X | [323] |
7143 SRW02490 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE402500 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD902510 | Annually | — | X | — |
7111 ZE802520 | Semi-annual | — | X | — |
7111 ZE902530 | Quarterly | — | X | — |
7111 ZB702540 | Monthly | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZG002550 | Informative smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7502560 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3002570 | Device number | — | X | — |
711002580 | Device number | — | X | [952] |
| SG8.SEQ | — | — | Must | — |
1229 ZG102590 | Informative profile data | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0402600 | Standard feed-in profile | — | X | — |
7037 E0102610 | synthetic method | — | X | — |
| SG10.CAV | — | — | Must | — |
711102620 | Code of the standardized profile | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZG202630 | Informative profile set data | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z1202640 | Profile set | — | X | — |
| SG10.CAV | — | — | Must | — |
711102650 | Code of the profile set | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0502660 | day-parameter-dependent feed-in profile | — | X | — |
7037 E0102670 | synthetic method | — | X | — |
7037 Z1002680 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711102690 | Code of the standardized profile | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z9902700 | Measuring station of the daily parameter (currently only the temperature is a permitted daily parameter) | — | X | — |
7059 ZA002710 | Climate zone of the daily parameter (currently is daily parameter) | — | X | — |
703702720 | ID of climate zone / temperature measuring point | — | X | — |
113102730 | Service provider | — | X | [58] |
3055 8902740 | Assigned by the trader (here grid operator) | — | X | — |
3055 29302750 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZG302760 | Informative reference profile data | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0502770 | day-parameter-dependent feed-in profile | — | X | — |
| SG10.CAV | — | — | Must | — |
711102780 | Code of the reference profile | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z6302790 | Informative market location address | — | X | — |
312402800 | Additional information for identification | — | — | — |
304202810 | Street and house number or PO box | — | — | S [166] M [212] |
316402820 | City | — | X | — |
325102830 | Postal code | — | X | — |
320702840 | Country name, code | — | X | — |
| UNT | — | — | Must | — |
007402850 | Number of segments in a message | — | X | — |
006202860 | Message reference number | — | X | — |
Conditions of this table
The free text of the 58 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [21] | If SG10 CCI+++ZA6 (forecast based on profiles) present in this SG8 |
| [32] | If more than one SG8 (reference to the location bundle structure) is present |
| [58] | If in this CCI the DE3055 with the code 293 is present |
| [102] | If SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) CAV+Z36 (TEP with ref. measurement) present in this SG8 |
| [103] | If SG9 QTY+265 (energy / power for day-parameter-dependent market location: estimated annual quantity total) present in this SG8 |
| [104] | If SG9 QTY+Z08 (energy / power for day-parameter-dependent market location: adjusted electrical energy according to Annex D) present in this SG8 |
| [105] | If SG9 QTY+Z10 (energy / power for day-parameter-dependent market location: power of the market location) present in this SG8 |
| [136] | If SG10 CCI+++E13 (meter type) CAV+EHZ (electronic household meter) present in this SG8 |
| [166] | If present |
| [173] | If DE1156 (consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is not present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [174] | If DE1156 consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [175] | If the object code in RFF+Z33 (reference to the object code in the location bundle structure) in DE1154 of the same SG8 SEQ+Z58 (assignment of location to the object code of the location bundle) is present in a further SG8 SEQ+Z58 with the same sequential number |
| [176] | If DE1153 with code Z34 upstream metering location is present in the same segment |
| [177] | If DE1153 with code Z35 upstream grid location is present in the same segment |
| [178] | If the LOC+Z18 (grid location) is present |
| [179] | If the object code in RFF+Z33 (reference to the object code in the location bundle structure) in DE1154 of the same SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle) is present in a further SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle) with an identical code in DE1229 |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [215] | If in the same SG8 (metering device data) SG10 CCI+++E13 CAV+MME (meter type: mME) is present |
| [269] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3, that are required at the tranche must be stated |
| [291] | If in the same SG8 (assignment of location to the object code of the location bundle) the RFF+Z37 is present |
| [314] | All OBIS codes in accordance with the code list of OBIS codes and media, chapter 3, that are required at the market location must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document Code list of configurations |
| [321] | If code EM is present in DE3155 in the same COM |
| [322] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [323] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3., that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document "Code list of configurations" |
| [333] | If in this RFF "reference to the location bundle structure" the code Z31 "location bundle structure" is present in DE1153 |
| [346] | If SG10 CCI+++E13 (meter type) CAV+MME (mME) present in this SG8 |
| [402] | If in the same SG8 (OBIS data of the metering device / smart meter gateway) an OBIS code of the value type "meter reading" is present in the PIA+5 |
| [412] | Only configuration product codes from the "EDI@Energy code list of configurations", chapter 4.2 Configuration products power curve definition, are permitted |
| [420] | If the RFF+Z14 (smart meter gateway) is present in this SG8 |
| [440] | If code Z35 (upstream grid location) is present in DE1153 in the same RFF |
| [441] | If RFF+Z14 (reference to the smart meter gateway) is not present in the SG8+SEQ+Z03/ZF5 (metering device data) for the device number of a meter named in this RFF DE1154 |
| [442] | If code Z34 (upstream metering location) is present in DE1153 in the same RFF |
| [447] | If in the same SG8 the CCI+Z50 (type of electricity generation) is present |
| [448] | If in the same SG8 the CCI+Z56 (storage) is present |
| [450] | If code Z32 (grid location) is present in DE1153 in the same RFF |
| [451] | If code Z18 (market location) is present in DE1153 in the same RFF |
| [452] | If code Z19 (metering location) is present in DE1153 in the same RFF |
| [456] | If code Z37 (technical resource) is present in DE1153 in the same RFF |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [665] | Note: If a meter is parameterized with a SMGW, no OBIS code numbers are stated for that meter. Only OBIS code numbers from the SMGW exist here |
| [699] | Note: The ID of the controllable resource via which the technical resource is controlled must be specified |
| [700] | Note: The ID of the grid location via which the technical resource is controlled must be specified |
| [902] | Format: Possible value: ≥ 0 |
| [914] | Format: Possible value: > 0 |
| [922] | Format: TR-ID |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [960] | Format: Grid location ID |
| [961] | Format: SR-ID |
| [2061] | Segment or segment group must be specified exactly once per SG4 IDE (transaction) |
| [2313] | To be specified exactly once per SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of the location to the object code of the location bundle) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
UNA:+.? '
UNB+UNOC:3+9900321000005:500+9903790000002:500+{{date}}:{{time}}+M37Q182E'
UNH+UNHM3OFU5DD+UTILMD:D:11A:UN:S2.1'
BGM+E44+BGMM38QNJX1'
DTM+137:202506051200?+00:303'
NAD+MS+9900321000005::293'
NAD+MR+9903790000002::293'
IDE+24+123456'
STS+7++ZY6'
LOC+Z18+E1688117482'
LOC+Z16+50074561188'
LOC+Z20+D417MLM8164'
LOC+Z19+C816417ST77'
LOC+Z17+DE0032106765712000000000000000037'
RFF+Z13:55095'
RFF+AAV:ABC1234567'
SEQ+ZD5'
RFF+Z31:9992000000034'
SEQ+ZD6'
RFF+Z32:E1688117482'
RFF+Z33:9992000001256'
SEQ+ZD6'
RFF+Z18:50074561188'
RFF+Z33:9992000001066'
SEQ+ZD6'
RFF+Z19:DE0032106765712000000000000000037'
RFF+Z33:9992000001214'
SEQ+ZD6'
RFF+Z37:D417MLM8164'
RFF+Z33:9992000001058'
SEQ+ZD7'
RFF+Z32:E1688117482'
CCI+Z49++ZF3'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39'
SEQ+ZE0'
RFF+Z32:E1688117482'
PIA+5+9991000000721:Z12'
CCI+Z53++ABC'
SEQ+Z98'
CCI+++ZB3'
CAV+Z90:4045399000077'
CAV+Z91:9904446000007::Z39:Z20'
CCI+++E03'
CAV+E06'
CCI+++Z83'
CAV+Z53'
CCI+++ZC0'
CCI+++Z34'
CAV+Z37'
SEQ+ZE3'
PIA+5+1-1?:1.29.0:SRW'
SEQ+ZE4'
PIA+5+9991000000721:Z12'
CCI+Z53++ABC'
SEQ+ZE6'
PIA+5+AUA:Z08'
SEQ+ZF0'
RFF+Z37:D417MLM8164'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z44:1500:KWT'
CCI+Z50'
CAV+ZF5'
SEQ+ZF1'
RFF+Z38:C816417ST77'
CCI+Z49'
CAV+ZF2:Z14'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39'
SEQ+ZF2'
RFF+Z38:C816417ST77'
PIA+5+9991000000721:Z12'
CCI+Z53++ABC'
SEQ+ZF3'
RFF+Z19:DE0032106765712000000000000000037'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39:Z20'
CAV+ZF0:9904446000007'
SEQ+ZF5'
RFF+Z19:DE0032106765712000000000000000037'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::EL001IK01013852469'
CCI+++E12'
CAV+AMR'
SEQ+ZF6'
RFF+MG:EL001IK01013852469'
PIA+5+1-1?:2.29.0:SRW'
NAD+Z63++Mustermann:Max++Str::1+Ort++12345+DE'
UNT+89+UNHM3OFU5DD'
UNZ+1+M37Q182E'[1 item
{6 fields
"data": {3 fields
"stammdaten": {9 fields
"MARKTLOKATION": [1 item
{15 fields
"marktlokationsTyp": [1 item
{1 field
"lokationsadresse": {6 fields
"zusatzInformation": {2 fields
"marktrollen": [2 items
{6 fields
{8 fields
"zaehlwerke": [1 item
{1 field
"energieherkunft": [1 item
{1 field
"NETZLOKATION": [1 item
{10 fields
"marktrollen": [1 item
{7 fields
"abrechnungsdaten": [1 item
"MESSLOKATION": [1 item
{6 fields
"marktrollen": [2 items
{8 fields
{6 fields
"TECHNISCHE_RESSOURCE": [1 item
{10 fields
"nennleistung": {1 field
"STEUERBARE_RESSOURCE": [1 item
{9 fields
"marktrollen": [1 item
{7 fields
"zugeordneteDefinition": {1 field
"LOKATIONSBUENDEL": [1 item
{6 fields
"zuordnungObjectcode": [4 items
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
"NETZNUTZUNGSVERTRAG": [1 item
{6 fields
"ZAEHLER": [1 item
{10 fields
"zaehlwerke": [1 item
{1 field
"geraete": [1 item
{1 field
"BILANZIERUNG": [1 item
{5 fields
"transaktionsdaten": {12 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Business data request | GPKE part 4 | Electricity | Step 2 |
| NB | NB | Business data request | GPKE part 4 | Electricity | Step 2 |
| MSB | MSB | Business data request | GPKE part 4 | Electricity | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response to GDA gen. MaLo |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 4 | Business data request | NB → LF | Response |
Transaction and responses
Role of this check identifier: response. Basis: the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Request: No reference recorded in the source. Neither the Prüfi table (reaktion_auf) nor the step sequence of the processes names the message that this response answers.
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfragereferenznummer | SG4.IDE+24.SG6.RFF+AAV | dokumentennummer |
RFF+AAV quotes the preceding message via its BGM; the target is the dokumentennummer of the request. Which request is meant is not determined on this page (see above) — the target field is thus named, but not proven.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 403 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type utilmd. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.