Check identifier 55035 — Response to GDA consuming MaLo
Check identifier 55035 · EDIFACT message type UTILMD · Format version 202604
Data structure
| Structure (BO4E) | Description | Format | 55035 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| BILANZIERUNG [ ] * | — | object[] | Must | — |
| detailsPrognosegrundlage 00010 | Forecast basis - If a day-parameter-dependent load profile with joint metering has to be specified, this is possible by repeating the CAV segment twice, stating the codes E02 and E14. | array | Must | — |
| prognosegrundlage * 00020 | Forecast basis | Enum Prognosegrundlage | Must | — |
WERTE | — | — | Must | — |
PROFILE | — | — | Must | — |
| jahresverbrauchsprognose | — | object | May | — |
| einheit 00030 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 00040 | Value | number (float) | X | — |
| lastprofile [ ] | — | object[] | May | — |
| bezeichnung 00050 | Designation of the profile | string | Must | — |
| einspeisung 00060 | Feed-in indicator | boolean | X | — |
| profilart 00070 | Profile category | Enum Profilart | X | — |
ART_STANDARDLASTPROFIL | — | — | X | — |
ART_TAGESPARAMETERABHAENGIGES_LASTPROFIL | — | — | X | — |
ART_LASTPROFIL | — | — | X | — |
| profilschar 00080 | Profile set of the profile | string | Must | — |
| verfahren 00090 | Profiling method | Enum Profilverfahren | X | — |
SYNTHETISCH | — | — | X | — |
ANALYTISCH | — | — | X | — |
| tagesparameter | — | object | May | — |
| dienstanbieter 00100 | dienstanbieter | string | Must | — |
| herausgeber 00110 | Herausgeber | Enum Herausgeber | Must | — |
NB | — | — | Must | — |
BDEW | — | — | Must | — |
TUM | — | — | Must | — |
| klimazone 00120 | klimazone | string | Must | — |
| temperaturmessstelle 00130 | temperaturmessstelle | string | Must | — |
| temperaturarbeit | — | object | May | — |
| einheit 00140 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | Must | — |
W | — | — | Must | — |
WH | — | — | Must | — |
KW | — | — | Must | — |
KWH | — | — | Must | — |
KVARH | — | — | Must | — |
MW | — | — | Must | — |
MWH | — | — | Must | — |
STUECK | — | — | Must | — |
KUBIKMETER | — | — | Must | — |
STUNDE | — | — | Must | — |
TAG | — | — | Must | — |
MONAT | — | — | Must | — |
JAHR | — | — | Must | — |
PROZENT | — | — | Must | — |
ANZAHL | — | — | Must | — |
VAR | — | — | Must | — |
KVAR | — | — | Must | — |
VARH | — | — | Must | — |
KWHK | — | — | Must | — |
Z16 | — | — | Must | — |
KWT | — | — | Must | — |
WATT_PRO_QUADRATMETER | — | — | Must | — |
METER_PRO_SEKUNDE | — | — | Must | — |
| wert 00150 | Value | number (float) | Must | — |
| LOKATIONSBUENDEL [ ] * | — | object[] | Must | — |
| lokationsbuendelNummer 00160 | lokationsbuendelNummer | integer | Must | — |
| lokationsbuendelstrukturId 00170 | lokationsbuendelstrukturId | string | Must | — |
| standardisierteLokationsbuendelstruktur * 00180 | standardisierteLokationsbuendelstruktur | boolean | Must | — |
| zuordnungObjectcode [ ] | — | object[] | May | — |
| referenzLokationsId 00190 | referenzLokationsId | string | Must | — |
| referenzLokationsTyp 00200 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| referenzMarktlokationTechnischeRessource 00210 | referenzMarktlokationTechnischeRessource | array | X | — |
| vorgelagerteLokationId 00220 | vorgelagerteLokationId | string | Must | — |
| vorgelagerteLokationTyp 00230 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| objectcode [ ] | — | object[] | May | — |
| lokationsbuendelNummer 00240 | lokationsbuendelNummer | integer | X | — |
| objectcode 00250 | objectcode | string | X | — |
| MARKTLOKATION [ ] * | — | object[] | Must | — |
| konfigurationsprodukt 00260 | konfigurationsprodukt | string | X | — |
| leistungskurvendefinition 00270 | Code of the assigned power curve definition for the object | string | X | — |
| marktlokationsId * 00280 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| messtechnischeEinordnung * 00290 | Metering classification from the UTILMD (IMS, KME_MME, KEINE_MESSUNG) | Enum MesstechnischeEinordnung | Must | — |
IMS | — | — | Must | — |
KME_MME | — | — | Must | — |
KEINE_MESSUNG | — | — | Must | — |
| netzebene * 00300 | Grid level at which the energy is drawn. For electricity, the voltage level of the supply; for gas, the pressure level. Example electricity: low voltage Example gas: low pressure. | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| lokationsadresse | — | object | May | — |
| hausnummer 00310 | House number and supplement | string | X | — |
| landescode 00320 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00330 | City | string | X | — |
| ortsteil 00340 | District | string | X | — |
| postfach 00350 | PO box | string | X | — |
| postleitzahl 00360 | Postal code | string | X | — |
| strasse 00370 | Street | string | X | — |
| zusatzInformation | — | object | May | — |
| zusatz1 00380 | Address supplement 1 | string | X | — |
| zusatz2 00390 | Address supplement 2 | string | X | — |
| zusatz3 00400 | Address supplement 3 | string | X | — |
| zusatz4 00410 | Address supplement 4 | string | X | — |
| zusatz5 00420 | Address supplement 5 | string | X | — |
| marktrollen [ ] * | — | object[] | Must | — |
| marktrolle 00430 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00440 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer * 00450 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00460 | weiterverpflichtet | boolean | X | — |
| netznutzungsabrechnungsdaten [ ] * | — | object[] | Must | — |
| abschlag 00470 | Instalment payment | number (float) | Must | — |
| anzahl 00480 | Number | integer | X | — |
| artikelId * 00490 | artikelId | string | X | — |
| artikelIdTyp * 00500 | List of article IDs, e.g. for standardized articles issued by the BDEW that replace the BDEW article number in the electricity market | Enum ArtikelIdTyp | X | — |
ARTIKELID | — | — | X | — |
GRUPPENARTIKELID | — | — | X | — |
| gemeinderabatt * 00510 | Municipal discount | number (float) | X | [103] |
| zuschlag 00520 | Surcharge | number (float) | Must | — |
| preisSingulaereBetriebsmittel | — | object | May | — |
| wert 00530 | wert | number (float) | Must | — |
| singulaereBetriebsmittel | — | object | May | — |
| wert 00540 | Value | number (float) | X | — |
| zaehlzeiten | — | object | May | — |
| register 00550 | Metering time period register | string | X | — |
| zaehlzeitDefinition 00560 | Metering time period definition | string | X | — |
| zaehlwerke [ ] * | — | object[] | Must | — |
| artEMobilitaet 00570 | ArtEmobilitaet | Enum ArtEmobilitaet | Must | — |
WB | — | — | Must | — |
LS | — | — | Must | — |
LP | — | — | Must | — |
| obisKennzahl * 00580 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| unterbrechbarkeit 00590 | Electricity consumption type / interruptibility market location | Enum Unterbrechbarkeit | Must | — |
UV | — | — | Must | — |
NUV | — | — | Must | — |
| verbrauchsart 00600 | Electricity consumption type/consumption type market location | array | Must | — |
| waermenutzung 00610 | Electricity consumption type / heat use market location | Enum Waermenutzung | Must | — |
SPEICHERHEIZUNG | — | — | Must | — |
WAERMEPUMPE | — | — | Must | — |
DIREKTHEIZUNG | — | — | Must | — |
WAERMEPUMPE_WAERME_KAELTE | — | — | Must | — |
WAERMEPUMPE_KAELTE | — | — | Must | — |
WAERMEPUMPE_WAERME | — | — | Must | — |
| wertegranularitaet 00620 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| zaehlzeiten | — | object | May | — |
| register 00630 | Metering time period register | string | X | — |
| zaehlzeitDefinition 00640 | Metering time period definition | string | X | — |
| MESSLOKATION [ ] | — | object[] | May | — |
| messlokationsId 00650 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00660 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00670 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00680 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00690 | weiterverpflichtet | boolean | X | — |
| NETZLOKATION [ ] | — | object[] | May | — |
| konfigurationsprodukt 00700 | konfigurationsprodukt | string | X | — |
| leistungskurvendefinition 00710 | Code of the assigned power curve definition for the object | string | X | — |
| netzlokationsId 00720 | Identification number of a grid location at which energy is either consumed or generated (like MarktlokationsId market location) | string | X | — |
| steuerkanal 00730 | Whether a control channel is assigned to the grid location and the grid location can therefore be controlled. ZF2: No control channel present ZF3: Control channel present | boolean | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00740 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00750 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00760 | Specifies the code value of the market role. | string | X | — |
| STEUERBARE_RESSOURCE [ ] | — | object[] | May | — |
| konfigurationsprodukt 00770 | konfigurationsprodukt | string | X | — |
| ressourcenId 00780 | ressourcenId | string | X | — |
| steuerkanal 00790 | Control channel | Enum Steuerkanal | X | — |
AN_AUS | — | — | X | — |
GESTUFT | — | — | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00800 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00810 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00820 | Specifies the code value of the market role. | string | X | — |
| zugeordneteDefinition | — | object | May | — |
| leistungskurvendefinition 00830 | leistungskurvendefinition | string | Must | — |
| schaltzeitdefinition 00840 | schaltzeitdefinition | string | Must | — |
| TECHNISCHE_RESSOURCE [ ] | — | object[] | May | — |
| art 00850 | Technical resource type | Enum TechnischeRessourceArt | Must | — |
STROMERZEUGUNG | — | — | Must | — |
STROMVERBRAUCH | — | — | Must | — |
SPEICHER | — | — | Must | — |
| artEMobilitaet 00860 | ArtEmobilitaet | Enum ArtEmobilitaet | Must | — |
WB | — | — | Must | — |
LS | — | — | Must | — |
LP | — | — | Must | — |
| einordnung 00870 | RessourceWechselmoeglichkeit | Enum RessourceWechselmoeglichkeit | Must | — |
WECHSELMOEGLICHKEIT_EINMALIG_NOCH_MOEGLICH | — | — | Must | — |
WECHSELMOEGLICHKEIT_NICHT_MOEGLICH | — | — | Must | — |
BEFRISTET_OHNE_WECHSELMOEGLICHKEIT | — | — | Must | — |
WECHSEL_WURDE_DURCHGEFUEHRT | — | — | Must | — |
| enwg 00880 | enwg | boolean | Must | — |
| inbetriebsetzungsdatum 00890 | Commissioning | Enum Inbetriebsetzung | Must | — |
INBETRIEBSETZUNG_NACH_2023 | — | — | Must | — |
INBETRIEBSETZUNG_VOR_2024 | — | — | Must | — |
| referenzNetzlokation 00900 | referenzNetzlokation | string | X | — |
| referenzSteuerbareRessource 00910 | referenzSteuerbareRessource | string | X | — |
| ressourcenId 00920 | ressourcenId | string | X | — |
| speicherart 00930 | Type of storage. Details storage type Example: CAV+ZF7' Storage type: ZF7: hydrogen storage ZF8: pumped storage ZF9: battery storage ZG6: other storage type | Enum Speicherart | Must | — |
WASSERSTOFFSPEICHER | — | — | Must | — |
PUMPSPEICHER | — | — | Must | — |
BATTERIESPEICHER | — | — | Must | — |
SONSTIGE_SPEICHERART | — | — | Must | — |
| speicherkapazitaet 00940 | Storage capacity Example: QTY+Z42:100:KWH' | number (float) | X | — |
| verbrauchsart 00950 | Consumption type of the technical resource Example: CAV+Z64' Z64: Power/light Z65: Heat ZE5: E-mobility ZA8: Street lighting | array | Must | — |
| waermenutzung 00960 | Heat usage Example: CAV+Z56' Z56: Storage heating Z57: Heat pump Z61: Direct heating | Enum Waermenutzung | Must | — |
SPEICHERHEIZUNG | — | — | Must | — |
WAERMEPUMPE | — | — | Must | — |
DIREKTHEIZUNG | — | — | Must | — |
WAERMEPUMPE_WAERME_KAELTE | — | — | Must | — |
WAERMEPUMPE_KAELTE | — | — | Must | — |
WAERMEPUMPE_WAERME | — | — | Must | — |
| weitereEinrichtung 00970 | weitereEinrichtung | boolean | Must | — |
| nennleistung | — | object | May | — |
| abgabe 00980 | Submission of the rated capacity | number (float) | X | — |
| aufnahme 00990 | Recording of the rated power | number (float) | X | — |
| ZAEHLER [ ] | — | object[] | May | — |
| gateway 01000 | Specification of a SMGW with which the meter is parameterised | string | X | — |
| messlokationsId 01010 | messlokationsId | string | X | — |
| messwerterfassung 01020 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| zaehlernummer 01030 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 01040 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 01050 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 01060 | The number printed on the device, which is assigned by the MSB. | string | Must | — |
| geraetetyp 01070 | List of possible billable device types | Enum Geraetetyp | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
ZWEIRICHTUNGSZAEHLER | — | — | Must | — |
RLM_ZAEHLER | — | — | Must | — |
IMS_ZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
MULTIPLEXANLAGE | — | — | Must | — |
PAUSCHALANLAGE | — | — | Must | — |
VERSTAERKERANLAGE | — | — | Must | — |
SUMMATIONSGERAET | — | — | Must | — |
IMPULSGEBER | — | — | Must | — |
EDL_21_ZAEHLERAUFSATZ | — | — | Must | — |
VIER_QUADRANTEN_LASTGANGZAEHLER | — | — | Must | — |
MENGENUMWERTER | — | — | Must | — |
STROMWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
DATENLOGGER | — | — | Must | — |
KOMMUNIKATIONSANSCHLUSS | — | — | Must | — |
MODEM | — | — | Must | — |
TELEKOMMUNIKATIONSEINRICHTUNG | — | — | Must | — |
KOMMUNIKATIONSEINRICHTUNG | — | — | Must | — |
DREHKOLBENGASZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MODERNE_MESSEINRICHTUNG | — | — | Must | — |
ELEKTRONISCHER_HAUSHALTSZAEHLER | — | — | Must | — |
STEUEREINRICHTUNG | — | — | Must | — |
TECHNISCHESTEUEREINRICHTUNG | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
OPTIONALE_ZUS_ZAEHLEINRICHTUNG | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER_IMS_MME | — | — | Must | — |
TARIFSCHALTGERAET_IMS_MME | — | — | Must | — |
RUNDSTEUEREMPFAENGER_IMS_MME | — | — | Must | — |
TEMPERATUR_KOMPENSATION | — | — | Must | — |
HOECHSTBELASTUNGS_ANZEIGER | — | — | Must | — |
SONSTIGES_GERAET | — | — | Must | — |
SMARTMETERGATEWAY | — | — | Must | — |
STEUERBOX | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
PLC_COM | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
WANDLER | — | — | Must | — |
BEFESTIGUNGSEINRICHTUNG | — | — | Must | — |
| zaehlwerke [ ] | — | object[] | May | — |
| konfiguration 01080 | Configuration (iMSys) of the meter register | string | X | — |
| obisKennzahl 01090 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| wertegranularitaet 01100 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer * 01110 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| dokumentennummer * 01120 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| kategorie * 01130 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 01140 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 01150 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 01160 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 01170 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| transaktionsgrundergaenzung * 01180 | Supplement to the transaction reason / UTILMD STS+7++E01+###+E03 | string | X | — |
| vorgangsnummer * 01190 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 01200 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 01210 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 01220 | Email address | string | Must | — |
| nachname 01230 | Surname (family name) of the contact person | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 01240 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 01250 | rufnummer | string | Must | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 01260 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 01270 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55035 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E4400070 | Information notification | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00160 | Information contact | — | X | — |
341200170 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800180 | Number / address | — | X | (([939] [321]) ∨ ([940] [322])) ∧ [514] |
3155 EM00190 | Electronic mail | — | X | [1P0..1] |
3155 FX00200 | Fax number | — | X | [1P0..1] |
3155 TE00210 | Telephone | — | X | [1P0..1] |
3155 AJ00220 | further telephone | — | X | [1P0..1] |
3155 AL00230 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00240 | Message recipient | — | X | — |
303900250 | MP-ID | — | X | — |
3055 900260 | GS1 | — | X | — |
3055 29300270 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400280 | Transaction | — | X | — |
740200290 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700300 | Transaction reason | — | X | — |
9013 ZY700310 | Response to GDA consuming MaLo | — | X | — |
9013 ZW400320 | Consuming market location | — | X | — |
9013 ZAP00330 | dormant market location | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1800340 | Grid location | — | X | — |
322500350 | ID of the grid location | — | X | [960] |
| SG5.LOC | — | — | Must | — |
3227 Z1600360 | Market location | — | X | — |
322500370 | ID of the market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2200380 | Dormant market location | — | X | — |
322500390 | ID of the dormant market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2000400 | Technical resource | — | X | — |
322500410 | ID of the technical resource | — | X | [922] |
| SG5.LOC | — | — | Must | — |
3227 Z1900420 | Controllable resource | — | X | — |
322500430 | ID of the controllable resource | — | X | [961] |
| SG5.LOC | — | — | Must | — |
3227 Z1700440 | Metering location | — | X | — |
322500450 | ID of the metering location | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300460 | Check identifier | — | X | — |
1154 5503500470 | GPKE / Response to GDA for consuming MaLo | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 AAV00480 | Number of the request | — | X | — |
115400490 | Transaction number | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZD500500 | Informative reference to the location bundle structure | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3100510 | Location bundle structure | — | X | — |
1153 Z3900520 | No standardized location bundle structure available | — | X | — |
115400530 | ID of the location bundle structure | — | X | [333] |
115600540 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.SEQ | — | — | Must | — |
1229 ZD600550 | Informative assignment of location to the object code of the location bundle | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200560 | Grid location | — | X | — |
1153 Z1800570 | Market location | — | X | — |
1153 Z1900580 | Metering location | — | X | — |
1153 Z3700590 | Technical resource | — | X | — |
115400600 | ID of a location | — | X | ([451] ∧ [950]) ⊻ ([452] ∧ [951]) ⊻ ([450] ∧ [960]) ⊻ ([456] ∧ [922]) |
| SG8.RFF | — | — | Must | [2313] |
1153 Z3300610 | Object code of the location in the location bundle structure | — | X | — |
115400620 | Object code | — | X | — |
115600630 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.RFF | — | — | Must | ([176] ∧ (([173] ∧ [179]) ⊻ ([174] ∧ [175]))) ⊻ ([177] ∧ [178] ∧ [179]) |
1153 Z3400640 | upstream metering location | — | X | — |
1153 Z3500650 | upstream grid location | — | X | — |
115400660 | ID of a location | — | X | ([442] ∧ [951]) ⊻ ([440] ∧ [960]) |
| SG8.RFF | — | — | Must | [179] ∧ [291] |
1153 Z1600670 | assigned market location | — | X | — |
115400680 | ID of the market location | — | X | [950] |
| SG8.SEQ | — | — | Must | — |
1229 ZD700690 | Informative data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200700 | Grid location | — | X | — |
115400710 | ID of the grid location | — | X | [960] |
| SG10.CCI | — | — | Must | — |
7059 Z4900720 | Control channel | — | X | — |
7037 ZF200730 | No control channel available | — | X | — |
7037 ZF300740 | Control channel present | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB300750 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9100760 | MSB | — | X | — |
113100770 | MP-ID | — | X | — |
7110 Z3900780 | Default metering point operator | — | X | — |
7110 Z4000790 | Competitive metering point operator | — | X | — |
7110 Z4100800 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE000810 | Informative product data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200820 | Grid location | — | X | — |
115400830 | ID of a grid location | — | X | [960] |
| SG8.PIA | — | — | Must | — |
4347 500840 | Product identification | — | X | — |
714000850 | Configuration product code | — | X | [412] |
7143 Z1200860 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5300870 | Code of the power curve definition | — | X | — |
703700880 | Code of the power curve definition | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z9800890 | Informative data of the market location | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 26500900 | Estimated annual quantity total/annual consumption forecast for specific energy for day-parameter-dependent market location | — | X | — |
6063 Z0800910 | Adjusted electrical energy in accordance with Annex D of the VDN guideline "Load profiles for interruptible consumption devices" | — | X | — |
606000920 | Quantity | — | X | [902] |
6411 Z1600930 | kWh/K (kilowatt hour/Kelvin) | — | X | [103] |
6411 KWH00940 | Kilowatt hour | — | X | [104] |
| SG9.QTY | — | — | Must | — |
6063 3100950 | Estimated annual quantity total | — | X | — |
606000960 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH00970 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB300980 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9000990 | ÜNB | — | X | — |
113101000 | MP-ID | — | X | — |
| SG10.CAV | — | — | Must | [345] |
7111 Z9101010 | MSB | — | X | — |
113101020 | MP-ID | — | X | — |
7110 Z3901030 | Default metering point operator | — | X | — |
7110 Z4001040 | Competitive metering point operator | — | X | — |
7110 Z4101050 | Fallback metering point operator | — | X | — |
7110 Z1901060 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2001070 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0301080 | Voltage level of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0301090 | Extra-high voltage | — | X | — |
7111 E0401100 | High voltage | — | X | — |
7111 E0501110 | Medium voltage | — | X | — |
7111 E0601120 | Low voltage | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z8301130 | Metering classification of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z5201140 | iMS | — | X | — |
7111 Z5301150 | kME / mME | — | X | — |
7111 Z6801160 | no measurement | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZC001170 | Forecast based on values | — | X | — |
7037 ZA601180 | Forecast based on profiles | — | X | — |
| SG10.CAV | — | — | Must | [21] ∧ ([2182] ⊻ ([90] ∧ [2183])) |
7111 E0201190 | SLP/SEP | — | X | [1P0..1] |
7111 E1401200 | TLP/TEP | — | X | [1P0..1] |
| SG8.SEQ | — | — | Must | — |
1229 ZE101210 | Informative grid usage billing data of the market location | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 Z0201220 | Group article ID / article ID | — | X | — |
714001230 | Product/service number | — | X | ([942] ([270] ⊻ [282]) ∧ [284]) ⊻ ([943] ([259] ⊻ [261]) ∧ [284]) ⊻ ([957] [285] ∧ [287]) ⊻ ([948] [286] ∧ [287]) |
7143 Z0901240 | Article ID | — | X | [393] ⊻ ([394] ∧ [397]) ⊻ [395] |
7143 Z1001250 | Group article ID | — | X | [392] ⊻ ([394] ∧ [398]) |
| SG9.QTY | — | — | Must | — |
6063 Z3801260 | Number of line items to be billed for the group article ID / article ID | — | X | — |
606001270 | Quantity | — | X | [914] ∧ [937] |
6411 H8701280 | Piece | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z1601290 | Municipal discount | — | X | — |
606001300 | Quantity | — | X | [902] ∧ [930] ∧ [938] |
6411 P101310 | Percent | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z3401320 | Surcharge | — | X | — |
6063 Z3501330 | Instalment payment | — | X | — |
6063 Z3701340 | No surcharge/discount | — | X | — |
606001350 | Quantity | — | X | ([914] ∧ [930] [140]) ⊻ ([926] ∧ [937] [172]) |
6411 P101360 | Percent | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z3301370 | Individually used equipment | — | X | — |
606001380 | Quantity | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z4401390 | Calculation price | — | X | — |
7037 ZD801400 | Day | — | X | — |
703601410 | Price, amount | — | X | [914] ∧ [946] |
| SG10.CCI | — | — | Must | — |
7059 Z3901420 | Code of the metering time period definition | — | X | — |
703701430 | Code of the metering time period definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3801440 | Code of the metering time period register | — | X | — |
703701450 | Code of the metering time period register | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE301460 | Informative OBIS data of the market location | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 501470 | Product identification | — | X | — |
714001480 | OBIS code of the market location | — | X | [314] |
7143 SRW01490 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401500 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD901510 | Annually | — | X | — |
7111 ZE801520 | Semi-annual | — | X | — |
7111 ZE901530 | Quarterly | — | X | — |
7111 ZB701540 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3901550 | Code of the metering time period definition | — | X | — |
703701560 | Code of the metering time period definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3801570 | Code of the metering time period register | — | X | — |
703701580 | Code of the metering time period register | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE401590 | Informative product data of the market location | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 501600 | Product identification | — | X | — |
714001610 | Product/service number | — | X | — |
7143 Z1201620 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5301630 | Code of the power curve definition | — | X | — |
703701640 | Code of the definition | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZE501650 | Informative consumption type and use of the OBIS code at the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1001660 | OBIS code | — | X | — |
115401670 | OBIS code | — | X | [525] |
| SG10.CCI | — | — | Must | — |
7059 Z1701680 | Type of electricity consumption | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z6401690 | Power/light | — | X | [1P0..1] |
7111 Z6501700 | Heat/cold | — | X | [1P0..1] |
7111 ZE501710 | E-mobility | — | X | [1P0..1] |
7111 ZA801720 | Street lighting | — | X | [1P0..1] |
7111 ZB301730 | Heat output control | — | X | [1P0..1] |
| SG10.CAV | — | — | Must | — |
7111 Z6201740 | interruptible consumption device | — | X | — |
7111 Z6301750 | non-interruptible consumption device | — | X | — |
| SG10.CAV | — | — | Must | [239] |
7111 Z5601760 | Storage heating | — | X | — |
7111 Z5701770 | Heat pump (unspecified) | — | X | — |
7111 Z6101780 | Direct heating | — | X | — |
7111 ZV501790 | Heat pump (heat and cold) | — | X | — |
7111 ZV601800 | Heat pump (cold) | — | X | — |
7111 ZV701810 | Heat pump (heat) | — | X | — |
| SG10.CAV | — | — | Must | [95] |
7111 ZE601820 | Wallbox | — | X | — |
7111 Z8701830 | E-mobility charging station | — | X | — |
7111 ZE701840 | Charging park | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF001850 | Informative data of the technical resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3701860 | Technical resource | — | X | — |
115401870 | ID of the technical resource | — | X | [922] |
| SG8.RFF | — | — | Should | [166] ∧ [699] |
1153 Z3801880 | Controllable resource | — | X | — |
115401890 | ID of the controllable resource | — | X | [961] |
| SG8.RFF | — | — | Should | [166] ∧ [700] |
1153 Z3201900 | Grid location | — | X | — |
115401910 | ID of the grid location | — | X | [960] |
| SG9.QTY | — | — | Must | — |
6063 Z4301920 | Rated power (input) | — | X | — |
606001930 | Quantity | — | X | — |
6411 KWT01940 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4401950 | Rated power (output) | — | X | — |
606001960 | Quantity | — | X | — |
6411 KWT01970 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4201980 | Storage capacity | — | X | — |
606001990 | Quantity | — | X | — |
6411 KWH02000 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1702010 | Type of electricity consumption | — | X | — |
7059 Z5602020 | Storage | — | X | — |
| SG10.CAV | — | — | Must | [446] |
7111 Z6402030 | Power/light | — | X | [1P0..1] |
7111 Z6502040 | Heat/cold | — | X | [1P0..1] |
7111 ZE502050 | E-mobility | — | X | [1P0..1] |
7111 ZA802060 | Street lighting | — | X | [1P0..1] |
| SG10.CAV | — | — | Must | [239] |
7111 Z5602070 | Storage heating | — | X | — |
7111 Z5702080 | Heat pump (unspecified) | — | X | — |
7111 Z6102090 | Direct heating | — | X | — |
7111 ZV502100 | Heat pump (heat and cold) | — | X | — |
7111 ZV602110 | Heat pump (cold) | — | X | — |
7111 ZV702120 | Heat pump (heat) | — | X | — |
| SG10.CAV | — | — | Must | [95] |
7111 ZE602130 | Wallbox | — | X | — |
7111 Z8702140 | E-mobility charging station | — | X | — |
7111 ZE702150 | Charging park | — | X | — |
| SG10.CAV | — | — | Must | [448] |
7111 ZF702160 | Hydrogen storage | — | X | — |
7111 ZF802170 | Pumped storage | — | X | — |
7111 ZF902180 | Battery storage | — | X | — |
7111 ZG602190 | Other storage type | — | X | — |
| SG10.CAV | — | — | Must | [446] ⊻ [448] |
7111 ZG802200 | Technical resource is covered by § 14a EnWG | — | X | — |
7111 ZG902210 | Technical resource is not covered by § 14a EnWG | — | X | — |
| SG10.CAV | — | — | Must | [461] |
7111 ZH002220 | Commissioning of the TR after 2023 | — | X | — |
7111 ZH102230 | Commissioning of the TR before 2024 | — | X | — |
| SG10.CAV | — | — | Must | [462] |
7111 ZH202240 | Option to change to the § 14a EnWG model pursuant to regulatory determination BK6-22-300 still available once | — | X | — |
7111 ZH302250 | Option to change to the § 14a EnWG model pursuant to regulatory determination BK6-22-300 not available | — | X | — |
7111 ZH402260 | Limited in time under the old § 14a EnWG model until 2028 without option to switch | — | X | — |
7111 ZH502270 | Change to the § 14a EnWG model pursuant to regulatory determination BK6-22-300 has been carried out | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z6302280 | Information on further technical equipment | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZH702290 | Further technical equipment present | — | X | — |
7111 ZH802300 | No further technical device available | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF102310 | Informative data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3802320 | Controllable resource | — | X | — |
115402330 | ID of the controllable resource | — | X | [961] |
| SG10.CCI | — | — | Must | — |
7059 Z4902340 | Control channel | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF202350 | Service description of the control channel | — | X | — |
1131 Z1402360 | On/Off | — | X | — |
1131 Z1502370 | Tiered | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB302380 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9102390 | MSB | — | X | — |
113102400 | MP-ID | — | X | — |
7110 Z3902410 | Default metering point operator | — | X | — |
7110 Z4002420 | Competitive metering point operator | — | X | — |
7110 Z4102430 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF202440 | Informative product data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3802450 | Controllable resource | — | X | — |
115402460 | ID of a controllable resource | — | X | [961] |
| SG8.PIA | — | — | Must | — |
4347 502470 | Product identification | — | X | — |
714002480 | Configuration product code | — | X | — |
7143 Z1202490 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5202500 | Code of the switching time definition | — | X | — |
7059 Z5302510 | Code of the power curve definition | — | X | — |
703702520 | Code of the definition | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF302530 | Informative data of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1902540 | Metering location | — | X | — |
115402550 | ID of the metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 ZB302560 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9102570 | MSB | — | X | — |
113102580 | MP-ID | — | X | — |
7110 Z3902590 | Default metering point operator | — | X | — |
7110 Z4002600 | Competitive metering point operator | — | X | — |
7110 Z4102610 | Fallback metering point operator | — | X | — |
7110 Z1902620 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2002630 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF002640 | gMSB | — | X | — |
113102650 | MP-ID | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF502660 | Informative metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1902670 | Metering location | — | X | — |
115402680 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Should | [166] ∧ [215] |
1153 Z1402690 | Smart meter gateway | — | X | — |
115402700 | Identification / number of the smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1302710 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AHZ02720 | analog household meter (three-phase current) | — | X | — |
7111 WSZ02730 | analog alternating current meter | — | X | — |
7111 LAZ02740 | Load curve meter | — | X | — |
7111 MAZ02750 | Maximum demand meter | — | X | — |
7111 MME02760 | modern metering device according to MsbG | — | X | — |
7111 EHZ02770 | electronic household meter | — | X | — |
7111 IVA02780 | Individual reconciliation (special equipment) | — | X | — |
7110 Z0102790 | EDL40 | — | X | [136] |
7110 Z0202800 | EDL21 | — | X | [136] |
7110 Z0302810 | other EHZ | — | X | [136] |
7110 Z0402820 | Standard | — | X | [346] |
7110 Z0502830 | MeDa meter | — | X | [346] |
| SG10.CAV | — | — | Must | — |
7111 Z3002840 | Device number | — | X | — |
711002850 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1202860 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR02870 | remotely readable meters | — | X | — |
7111 MMR02880 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZF602890 | Informative OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [665] |
1153 MG02900 | Device number of the meter | — | X | [441] |
1153 Z1402910 | Smart meter gateway | — | X | — |
115402920 | Device number | — | X | — |
| SG8.RFF | — | — | Must | [402] ∧ [420] |
1153 AGK02930 | Application reference number | — | X | — |
115402940 | Reference, identification | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 502950 | Product identification | — | X | — |
714002960 | OBIS code of the metering device | — | X | [323] |
7143 SRW02970 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE402980 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD902990 | Annually | — | X | — |
7111 ZE803000 | Semi-annual | — | X | — |
7111 ZE903010 | Quarterly | — | X | — |
7111 ZB703020 | Monthly | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZG003030 | Informative smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7503040 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3003050 | Device number | — | X | — |
711003060 | Device number | — | X | [952] |
| SG8.SEQ | — | — | Must | — |
1229 ZG103070 | Informative profile data | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0203080 | Standard load profile | — | X | — |
7037 E0103090 | synthetic method | — | X | — |
7037 Z1003100 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711103110 | Code of the standardized profile | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZG203120 | Informative profile set data | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z1203130 | Profile set | — | X | — |
| SG10.CAV | — | — | Must | — |
711103140 | Code of the profile set | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0303150 | day-parameter-dependent load profile | — | X | — |
7037 E0103160 | synthetic method | — | X | — |
7037 Z1003170 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711103180 | Code of the standardized profile | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z9903190 | Measuring station of the daily parameter (currently only the temperature is a permitted daily parameter) | — | X | — |
7059 ZA003200 | Climate zone of the daily parameter (currently is daily parameter) | — | X | — |
703703210 | ID of climate zone / temperature measuring point | — | X | — |
113103220 | Service provider | — | X | [58] |
3055 8903230 | Assigned by the trader (here grid operator) | — | X | — |
3055 29303240 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z6303250 | Informative market location address | — | X | — |
312403260 | Additional information for identification | — | — | — |
304203270 | Street and house number or PO box | — | — | S [166] M [212] |
316403280 | City | — | X | — |
325103290 | Postal code | — | X | — |
320703300 | Country name, code | — | X | — |
| UNT | — | — | Must | — |
007403310 | Number of segments in a message | — | X | — |
006203320 | Message reference number | — | X | — |
Conditions of this table
The free text of the 87 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [21] | If SG10 CCI+++ZA6 (forecast based on profiles) present in this SG8 |
| [32] | If more than one SG8 (reference to the location bundle structure) is present |
| [58] | If in this CCI the DE3055 with the code 293 is present |
| [90] | If SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) present once with CAV+E14 (TLP/TEP) and once with CAV+E02 (SLP/SEP) in this SG8 |
| [95] | If in the same SG10 the CCI+Z17 (type of electricity consumption) CAV+ZE5 (e-mobility) is present |
| [103] | If SG9 QTY+265 (energy / power for day-parameter-dependent market location: estimated annual quantity total) present in this SG8 |
| [104] | If SG9 QTY+Z08 (energy / power for day-parameter-dependent market location: adjusted electrical energy according to Annex D) present in this SG8 |
| [136] | If SG10 CCI+++E13 (meter type) CAV+EHZ (electronic household meter) present in this SG8 |
| [140] | If Z34/Z35 (surcharge/instalment payment) is present in DE6063 in the same QTY |
| [166] | If present |
| [172] | If Z37 (no surcharge or instalment payment) is present in DE6063 in the same QTY |
| [173] | If DE1156 (consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is not present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [174] | If DE1156 consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [175] | If the object code in RFF+Z33 (reference to the object code in the location bundle structure) in DE1154 of the same SG8 SEQ+Z58 (assignment of location to the object code of the location bundle) is present in a further SG8 SEQ+Z58 with the same sequential number |
| [176] | If DE1153 with code Z34 upstream metering location is present in the same segment |
| [177] | If DE1153 with code Z35 upstream grid location is present in the same segment |
| [178] | If the LOC+Z18 (grid location) is present |
| [179] | If the object code in RFF+Z33 (reference to the object code in the location bundle structure) in DE1154 of the same SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle) is present in a further SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle) with an identical code in DE1229 |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [215] | If in the same SG8 (metering device data) SG10 CCI+++E13 CAV+MME (meter type: mME) is present |
| [239] | If in the same SG10 the CCI+Z17 (type of electricity consumption) is present in the CAV+Z65 (heat/cooling) |
| [259] | If the code in DE7140 in this PIA contains 1-01, 1-03, 1-05 |
| [261] | If the code in DE7140 in this PIA begins with 1-07-1/2, 1-10-1/2/4/5/6/7/8/9, 1-11-1 |
| [270] | If the code in DE7140 in this PIA begins with 1-02, 1-04, 1-06, 1-09 |
| [282] | If in this PIA the code in DE7140 contains 1-01-6-005, 1-01-9-001/002, 1-07-3-001, 1- 08-1-001, 1-08-3-001, 1-08-4-001/002/003/004, 1-10-3-001 |
| [284] | Permitted codes from the code list of the group article and article ID are marked with X in the UTILMD/code usage column |
| [285] | If the code in DE7140 in this PIA is specified as 1-08-3-AGS |
| [286] | If the code in DE7140 in this PIA is 1-08-1/2/4/5-AGS-KG |
| [287] | Permitted codes from the PRICAT BGM+Z70 (price sheet for grid usage) of the responsible NB |
| [291] | If in the same SG8 (assignment of location to the object code of the location bundle) the RFF+Z37 is present |
| [314] | All OBIS codes in accordance with the code list of OBIS codes and media, chapter 3, that are required at the market location must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document Code list of configurations |
| [321] | If code EM is present in DE3155 in the same COM |
| [322] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [323] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3., that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document "Code list of configurations" |
| [333] | If in this RFF "reference to the location bundle structure" the code Z31 "location bundle structure" is present in DE1153 |
| [345] | If SG5 LOC+Z17 (metering location) is present |
| [346] | If SG10 CCI+++E13 (meter type) CAV+MME (mME) present in this SG8 |
| [392] | If the code in this PIA is specified in the format n1-n2-n1 |
| [393] | If the code in this PIA is specified in the format n1-n2-n1-n3 |
| [394] | If the code in this PIA is specified in the format n1-n2-n1-n8-n2 |
| [395] | If the code in this PIA is specified in the format n1-n2-n1-n8 |
| [397] | If the code in DE7140 in this PIA begins with 1-08-1/1-08-4 |
| [398] | If the code in DE7140 in this PIA begins with 1-08-2/1-08-5 |
| [402] | If in the same SG8 (OBIS data of the metering device / smart meter gateway) an OBIS code of the value type "meter reading" is present in the PIA+5 |
| [412] | Only configuration product codes from the "EDI@Energy code list of configurations", chapter 4.2 Configuration products power curve definition, are permitted |
| [420] | If the RFF+Z14 (smart meter gateway) is present in this SG8 |
| [440] | If code Z35 (upstream grid location) is present in DE1153 in the same RFF |
| [441] | If RFF+Z14 (reference to the smart meter gateway) is not present in the SG8+SEQ+Z03/ZF5 (metering device data) for the device number of a meter named in this RFF DE1154 |
| [442] | If code Z34 (upstream metering location) is present in DE1153 in the same RFF |
| [446] | If in the same SG8 the CCI+Z17 (type of electricity consumption) is present |
| [448] | If in the same SG8 the CCI+Z56 (storage) is present |
| [450] | If code Z32 (grid location) is present in DE1153 in the same RFF |
| [451] | If code Z18 (market location) is present in DE1153 in the same RFF |
| [452] | If code Z19 (metering location) is present in DE1153 in the same RFF |
| [456] | If code Z37 (technical resource) is present in DE1153 in the same RFF |
| [461] | If in the same SG10 the CCI (type and use of the technical resource) is present in the CAV+ZG8 (technical resource falls under § 14a EnWG) |
| [462] | If in the same SG10 the CCI+Z17 (type of electricity consumption) is present in the CAV+ZH1 (commissioning of the TR before 2024) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [525] | Note: Only the OBIS codes that were transmitted by the MSB in the previous master data exchange for this market location at this point in time are permitted |
| [665] | Note: If a meter is parameterized with a SMGW, no OBIS code numbers are stated for that meter. Only OBIS code numbers from the SMGW exist here |
| [699] | Note: The ID of the controllable resource via which the technical resource is controlled must be specified |
| [700] | Note: The ID of the grid location via which the technical resource is controlled must be specified |
| [902] | Format: Possible value: ≥ 0 |
| [914] | Format: Possible value: > 0 |
| [922] | Format: TR-ID |
| [926] | Format: Possible value: 0 |
| [930] | Format: max. 2 decimal places |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [938] | Format: Possible value: <= 10 |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [942] | Format: n1-n2-n1-n3 |
| [943] | Format: n1-n2-n1 |
| [946] | Format: max. 11 decimal places |
| [948] | Format: n1-n2-n1-n8-n2 |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [957] | Format: n1-n2-n1-n8 |
| [960] | Format: Grid location ID |
| [961] | Format: SR-ID |
| [2182] | Segment group must be specified exactly once per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2183] | Segment group must be specified exactly twice per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2313] | To be specified exactly once per SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of the location to the object code of the location bundle) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
Example 1
UNA:+.? '
UNB+UNOC:3+9900321000005:500+9903790000002:500+{{date}}:{{time}}+M37L81OQ'
UNH+UNHM3E13A90+UTILMD:D:11A:UN:S2.1'
BGM+E44+BGMM3RPZDFA'
DTM+137:202510011200?+00:303'
NAD+MS+9900321000005::293'
NAD+MR+9903790000002::293'
IDE+24+123456'
STS+7++ZY7+ZAP'
LOC+Z18+E1688117482'
LOC+Z16+50074561188'
LOC+Z22+50363198102'
LOC+Z20+D417MLM8164'
LOC+Z19+C816417ST77'
LOC+Z17+DE0032106765712000000000000000037'
RFF+Z13:55035'
RFF+AAV:ABC1234567'
SEQ+ZD5'
RFF+Z31:9992000000026'
SEQ+ZD6'
RFF+Z32:E1688117482'
RFF+Z33:9992000001256'
SEQ+ZD6'
RFF+Z18:50074561188'
RFF+Z33:9992000001016'
SEQ+ZD6'
RFF+Z19:DE0032106765712000000000000000037'
RFF+Z33:9992000001032'
SEQ+ZD6'
RFF+Z37:D417MLM8164'
RFF+Z33:9992000001024'
SEQ+ZD7'
RFF+Z32:E1688117482'
CCI+Z49++ZF2'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39'
SEQ+ZE0'
RFF+Z32:E1688117482'
PIA+5+9991000000721:Z12'
CCI+Z53++ABC'
SEQ+Z98'
QTY+31:2000:KWH'
CCI+++ZB3'
CAV+Z90:4045399000077'
CAV+Z91:9904446000007::Z39:Z19'
CCI+++E03'
CAV+E06'
CCI+++Z83'
CAV+Z53'
CCI+++ZA6'
CAV+E02'
SEQ+ZE1'
PIA+Z02+1-02-0-001:Z09'
QTY+Z16:0:P1'
QTY+Z37:0:P1'
SEQ+ZE3'
PIA+5+1-1?:1.9.0:SRW'
CCI+++ZE4'
CAV+ZD9'
SEQ+ZE4'
PIA+5+9991000000721:Z12'
CCI+Z53++ABC'
SEQ+ZF0'
RFF+Z37:D417MLM8164'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z43:1000:KWT'
CCI+Z17'
CAV+Z64'
CAV+ZG8'
CAV+ZH1'
CAV+ZH2'
CCI+Z63'
CAV+ZH8'
SEQ+ZF1'
RFF+Z38:C816417ST77'
CCI+Z49'
CAV+ZF2:Z14'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39'
SEQ+ZF2'
RFF+Z38:C816417ST77'
PIA+5+9991000000721:Z12'
CCI+Z53++ABC'
SEQ+ZF3'
RFF+Z19:DE0032106765712000000000000000037'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39:Z19'
CAV+ZF0:9904446000007'
SEQ+ZF5'
RFF+Z19:DE0032106765712000000000000000037'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::EL001IK01013852469'
CCI+++E12'
CAV+MMR'
SEQ+ZF6'
RFF+MG:EL001IK01013852469'
PIA+5+1-1?:1.8.0:SRW'
CCI+++ZE4'
CAV+ZD9'
SEQ+ZG1'
CCI+Z02++E01'
CAV+H0'
NAD+Z63++Mustermann:Max++Str::1+Ort++12345+DE'
UNT+104+UNHM3E13A90'
UNZ+1+M37L81OQ'[1 item
{6 fields
"data": {3 fields
"stammdaten": {9 fields
"MARKTLOKATION": [2 items
{14 fields
"marktlokationsTyp": [1 item
{1 field
"lokationsadresse": {6 fields
"zusatzInformation": {2 fields
"marktrollen": [2 items
{6 fields
{8 fields
"zaehlwerke": [1 item
{2 fields
"netznutzungsabrechnungsdaten": [1 item
{3 fields
{5 fields
"marktlokationsTyp": [1 item
{1 field
"NETZLOKATION": [1 item
{9 fields
"marktrollen": [1 item
{7 fields
"MESSLOKATION": [1 item
{6 fields
"marktrollen": [2 items
{8 fields
{6 fields
"TECHNISCHE_RESSOURCE": [1 item
{14 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
"STEUERBARE_RESSOURCE": [1 item
{9 fields
"marktrollen": [1 item
{7 fields
"zugeordneteDefinition": {1 field
"LOKATIONSBUENDEL": [1 item
{6 fields
"zuordnungObjectcode": [4 items
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
"NETZNUTZUNGSVERTRAG": [1 item
{6 fields
"ZAEHLER": [1 item
{10 fields
"zaehlwerke": [1 item
{2 fields
"geraete": [1 item
{1 field
"BILANZIERUNG": [1 item
{8 fields
"lastprofile": [1 item
{5 fields
"jahresverbrauchsprognose": {2 fields
"detailsPrognosegrundlage": [1 item
"transaktionsdaten": {13 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 2
UNA:+.? '
UNB+UNOC:3+9900321000005:500+9903790000002:500+{{date}}:{{time}}+M37L81OQ'
UNH+UNHM3E13A90+UTILMD:D:11A:UN:S2.1'
BGM+E44+BGMM3RPZDFA'
DTM+137:202510011200?+00:303'
NAD+MS+9900321000005::293'
NAD+MR+9903790000002::293'
IDE+24+123456'
STS+7++ZY7+ZAP'
LOC+Z18+E1688117482'
LOC+Z16+50074561188'
LOC+Z22+50363198102'
LOC+Z20+D417MLM8164'
LOC+Z19+C816417ST77'
LOC+Z17+DE0032106765712000000000000000037'
RFF+Z13:55035'
RFF+AAV:ABC1234567'
SEQ+ZD5'
RFF+Z31:9992000000026'
SEQ+ZD6'
RFF+Z32:E1688117482'
RFF+Z33:9992000001256'
SEQ+ZD6'
RFF+Z18:50074561188'
RFF+Z33:9992000001016'
SEQ+ZD6'
RFF+Z19:DE0032106765712000000000000000037'
RFF+Z33:9992000001032'
SEQ+ZD6'
RFF+Z37:D417MLM8164'
RFF+Z33:9992000001024'
SEQ+ZD7'
RFF+Z32:E1688117482'
CCI+Z49++ZF2'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39'
SEQ+ZE0'
RFF+Z32:E1688117482'
PIA+5+9991000000721:Z12'
CCI+Z53++ABC'
SEQ+Z98'
QTY+31:2000:KWH'
CCI+++ZB3'
CAV+Z90:4045399000077'
CAV+Z91:9904446000007::Z39:Z19'
CCI+++E03'
CAV+E06'
CCI+++Z83'
CAV+Z53'
CCI+++ZA6'
CAV+E02'
SEQ+ZE1'
PIA+Z02+1-02-0-001:Z09'
QTY+Z16:0:P1'
QTY+Z37:0:P1'
SEQ+ZE3'
PIA+5+1-1?:1.9.0:SRW'
CCI+++ZE4'
CAV+ZD9'
SEQ+ZE4'
PIA+5+9991000000721:Z12'
CCI+Z53++ABC'
SEQ+ZF0'
RFF+Z37:D417MLM8164'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z43:1000:KWT'
QTY+Z44:500:KWT'
QTY+Z42:2000:KWH'
CCI+Z56'
CAV+ZG6'
CAV+ZG8'
CAV+ZH1'
CCI+Z63'
CAV+ZH8'
SEQ+ZF1'
RFF+Z38:C816417ST77'
CCI+Z49'
CAV+ZF2:Z14'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39'
SEQ+ZF2'
RFF+Z38:C816417ST77'
PIA+5+9991000000721:Z12'
CCI+Z53++ABC'
SEQ+ZF3'
RFF+Z19:DE0032106765712000000000000000037'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39:Z19'
CAV+ZF0:9904446000007'
SEQ+ZF5'
RFF+Z19:DE0032106765712000000000000000037'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::EL001IK01013852469'
CCI+++E12'
CAV+MMR'
SEQ+ZF6'
RFF+MG:EL001IK01013852469'
PIA+5+1-1?:1.8.0:SRW'
CCI+++ZE4'
CAV+ZD9'
SEQ+ZG1'
CCI+Z02++E01'
CAV+H0'
NAD+Z63++Mustermann:Max++Str::1+Ort++12345+DE'
UNT+105+UNHM3E13A90'
UNZ+1+M37L81OQ'[1 item
{6 fields
"data": {3 fields
"stammdaten": {9 fields
"MARKTLOKATION": [2 items
{14 fields
"marktlokationsTyp": [1 item
{1 field
"lokationsadresse": {6 fields
"zusatzInformation": {2 fields
"marktrollen": [2 items
{6 fields
{8 fields
"zaehlwerke": [1 item
{2 fields
"netznutzungsabrechnungsdaten": [1 item
{3 fields
{5 fields
"marktlokationsTyp": [1 item
{1 field
"NETZLOKATION": [1 item
{9 fields
"marktrollen": [1 item
{7 fields
"MESSLOKATION": [1 item
{6 fields
"marktrollen": [2 items
{8 fields
{6 fields
"TECHNISCHE_RESSOURCE": [1 item
{15 fields
"nennleistung": {2 fields
"STEUERBARE_RESSOURCE": [1 item
{9 fields
"marktrollen": [1 item
{7 fields
"zugeordneteDefinition": {1 field
"LOKATIONSBUENDEL": [1 item
{6 fields
"zuordnungObjectcode": [4 items
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
"NETZNUTZUNGSVERTRAG": [1 item
{6 fields
"ZAEHLER": [1 item
{10 fields
"zaehlwerke": [1 item
{2 fields
"geraete": [1 item
{1 field
"BILANZIERUNG": [1 item
{8 fields
"lastprofile": [1 item
{5 fields
"jahresverbrauchsprognose": {2 fields
"detailsPrognosegrundlage": [1 item
"transaktionsdaten": {13 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Example 3
UNA:+.? '
UNB+UNOC:3+9900321000005:500+9903790000002:500+{{date}}:{{time}}+M37L81OQ'
UNH+UNHM3E13A90+UTILMD:D:11A:UN:S2.1'
BGM+E44+BGMM3RPZDFA'
DTM+137:202506051200?+00:303'
NAD+MS+9900321000005::293'
NAD+MR+9903790000002::293'
IDE+24+123456'
STS+7++ZY7+ZAP'
LOC+Z18+E1688117482'
LOC+Z16+50074561188'
LOC+Z22+50363198102'
LOC+Z20+D417MLM8164'
LOC+Z19+C816417ST77'
LOC+Z17+DE0032106765712000000000000000037'
RFF+Z13:55035'
RFF+AAV:ABC1234567'
SEQ+ZD5'
RFF+Z31:9992000000026'
SEQ+ZD6'
RFF+Z32:E1688117482'
RFF+Z33:9992000001256'
SEQ+ZD6'
RFF+Z18:50074561188'
RFF+Z33:9992000001016'
SEQ+ZD6'
RFF+Z19:DE0032106765712000000000000000037'
RFF+Z33:9992000001032'
SEQ+ZD6'
RFF+Z37:D417MLM8164'
RFF+Z33:9992000001024'
SEQ+ZD7'
RFF+Z32:E1688117482'
CCI+Z49++ZF2'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39'
SEQ+ZE0'
RFF+Z32:E1688117482'
PIA+5+9991000000721:Z12'
CCI+Z53++ABC'
SEQ+Z98'
QTY+31:2000:KWH'
CCI+++ZB3'
CAV+Z90:4045399000077'
CAV+Z91:9904446000007::Z39:Z19'
CCI+++E03'
CAV+E06'
CCI+++Z83'
CAV+Z53'
CCI+++ZA6'
CAV+E02'
SEQ+ZE1'
PIA+Z02+1-02-0-001:Z09'
QTY+Z16:0:P1'
QTY+Z37:0:P1'
SEQ+ZE3'
PIA+5+1-1?:1.9.0:SRW'
CCI+++ZE4'
CAV+ZD9'
SEQ+ZE4'
PIA+5+9991000000721:Z12'
CCI+Z53++ABC'
SEQ+ZF0'
RFF+Z37:D417MLM8164'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z43:1000:KWT'
CCI+Z17'
CAV+Z64'
CAV+ZG8'
CAV+ZH1'
CAV+ZH2'
CCI+Z63'
CAV+ZH8'
SEQ+ZF1'
RFF+Z38:C816417ST77'
CCI+Z49'
CAV+ZF2:Z14'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39'
SEQ+ZF2'
RFF+Z38:C816417ST77'
PIA+5+9991000000721:Z12'
CCI+Z53++ABC'
SEQ+ZF3'
RFF+Z19:DE0032106765712000000000000000037'
CCI+++ZB3'
CAV+Z91:9904446000007::Z39:Z19'
CAV+ZF0:9904446000007'
SEQ+ZF5'
RFF+Z19:DE0032106765712000000000000000037'
CCI+++E13'
CAV+AHZ'
CAV+Z30:::EL001IK01013852469'
CCI+++E12'
CAV+MMR'
SEQ+ZF6'
RFF+MG:EL001IK01013852469'
PIA+5+1-1?:1.8.0:SRW'
CCI+++ZE4'
CAV+ZD9'
SEQ+ZG1'
CCI+Z02++E01'
CAV+H0'
NAD+Z63++Mustermann:Max++Str::1+Ort++12345+DE'
UNT+104+UNHM3E13A90'
UNZ+1+M37L81OQ'[1 item
{6 fields
"data": {3 fields
"stammdaten": {9 fields
"MARKTLOKATION": [2 items
{14 fields
"marktlokationsTyp": [1 item
{1 field
"lokationsadresse": {6 fields
"zusatzInformation": {2 fields
"marktrollen": [2 items
{6 fields
{8 fields
"zaehlwerke": [1 item
{2 fields
"netznutzungsabrechnungsdaten": [1 item
{3 fields
{5 fields
"marktlokationsTyp": [1 item
{1 field
"NETZLOKATION": [1 item
{9 fields
"marktrollen": [1 item
{7 fields
"MESSLOKATION": [1 item
{6 fields
"marktrollen": [2 items
{8 fields
{6 fields
"TECHNISCHE_RESSOURCE": [1 item
{14 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
"STEUERBARE_RESSOURCE": [1 item
{9 fields
"marktrollen": [1 item
{7 fields
"zugeordneteDefinition": {1 field
"LOKATIONSBUENDEL": [1 item
{6 fields
"zuordnungObjectcode": [4 items
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
"NETZNUTZUNGSVERTRAG": [1 item
{6 fields
"ZAEHLER": [1 item
{10 fields
"zaehlwerke": [1 item
{2 fields
"geraete": [1 item
{1 field
"BILANZIERUNG": [1 item
{8 fields
"lastprofile": [1 item
{5 fields
"jahresverbrauchsprognose": {2 fields
"detailsPrognosegrundlage": [1 item
"transaktionsdaten": {13 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Business data request | GPKE part 4 | Electricity | Step 2 |
| NB | NB | Business data request | GPKE part 4 | Electricity | Step 2 |
| MSB | MSB | Business data request | GPKE part 4 | Electricity | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response to GDA consum. MaLo |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 4 | Business data request | NB → LF | Response |
Transaction and responses
Role of this check identifier: response. Basis: the title or the action of the Prüfi table begins with “response”. The title names no polarity — whether this message confirms or rejects is decided by the response code, not by the check identifier.
Request: No reference recorded in the source. Neither the Prüfi table (reaktion_auf) nor the step sequence of the processes names the message that this response answers.
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfragereferenznummer | SG4.IDE+24.SG6.RFF+AAV | dokumentennummer |
RFF+AAV quotes the preceding message via its BGM; the target is the dokumentennummer of the request. Which request is meant is not determined on this page (see above) — the target field is thus named, but not proven.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 462 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains 3 transactions for this check identifier under the message type utilmd. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.