Check identifier 55653 — Change to data of MeLo
Check identifier 55653 · EDIFACT message type UTILMD · format version 202610
Data structure
| Structure (BO4E) | Description | Format | 55653 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| datenqualitaet 00010 | Data quality | Enum Datenqualitaet | X | — |
ERWARTETE_DATEN | — | — | X | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | X | — |
INFORMATIVE_DATEN | — | — | X | — |
GUELTIGE_DATEN | — | — | X | — |
KEINE_DATEN | — | — | X | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | X | — |
KEINE_DATEN_ERWARTET | — | — | X | — |
DIFFERENZ_DATEN | — | — | X | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | X | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | X | — |
| messlokationsId * 00020 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| netzebenemessung 00030 | Grid level | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| ablesekartenempfaenger | — | object | May | — |
| anrede 00040 | The form of address for the GePa, e.g. Mr. | string | X | — |
| gewerbekennzeichnung 00050 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | X | — |
| name1 00060 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00070 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00080 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00090 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 00100 | House number and supplement | string | X | — |
| landescode 00110 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00120 | City | string | X | — |
| ortsteil 00130 | District | string | X | — |
| postfach 00140 | PO box | string | X | — |
| postleitzahl 00150 | Postal code | string | X | — |
| strasse 00160 | Street | string | X | — |
| gueltigkeitszeitraum | — | object | May | — |
| zeitraumId 00170 | zeitraumId | integer | X | — |
| VERWENDUNGSZEITRAUM [ ] * | — | object[] | Must | — |
| datenqualitaet * 00180 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| verwendungAb * 00190 | verwendungAb | string (date-time) | X | — |
| verwendungBis 00200 | verwendungBis | string (date-time) | X | — |
| zeitraumId * 00210 | zeitraumId | integer | Must | — |
| ZAEHLER [ ] | — | object[] | May | — |
| datenqualitaet 00220 | Data quality | Enum Datenqualitaet | X | — |
ERWARTETE_DATEN | — | — | X | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | X | — |
INFORMATIVE_DATEN | — | — | X | — |
GUELTIGE_DATEN | — | — | X | — |
KEINE_DATEN | — | — | X | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | X | — |
KEINE_DATEN_ERWARTET | — | — | X | — |
DIFFERENZ_DATEN | — | — | X | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | X | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | X | — |
| gateway 00230 | Specification of a SMGW with which the meter is parameterised | string | X | — |
| tarifart 00240 | Specification regarding supported tariff types. | Enum Tarifart | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
SMART_METER | — | — | Must | — |
LEISTUNGSGEMESSEN | — | — | Must | — |
| zaehlerauspraegung 00250 | Specification regarding the direction of the meter. | Enum Zaehlerauspraegung | Must | — |
EINRICHTUNGSZAEHLER | — | — | Must | — |
ZWEIRICHTUNGSZAEHLER | — | — | Must | — |
| zaehlernummer 00260 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 00270 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 00280 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 00290 | The number printed on the device, which is assigned by the MSB. | string | X | — |
| geraetetyp 00300 | List of possible billable device types | Enum Geraetetyp | Should | [166] ∧ [215] |
WECHSELSTROMZAEHLER | — | — | Should | — |
DREHSTROMZAEHLER | — | — | Should | — |
ZWEIRICHTUNGSZAEHLER | — | — | Should | — |
RLM_ZAEHLER | — | — | Should | — |
IMS_ZAEHLER | — | — | Should | — |
BALGENGASZAEHLER | — | — | Should | — |
MAXIMUMZAEHLER | — | — | Should | — |
MULTIPLEXANLAGE | — | — | Should | — |
PAUSCHALANLAGE | — | — | Should | — |
VERSTAERKERANLAGE | — | — | Should | — |
SUMMATIONSGERAET | — | — | Should | — |
IMPULSGEBER | — | — | Should | — |
EDL_21_ZAEHLERAUFSATZ | — | — | Should | — |
VIER_QUADRANTEN_LASTGANGZAEHLER | — | — | Should | — |
MENGENUMWERTER | — | — | Should | — |
STROMWANDLER | — | — | Should | — |
SPANNUNGSWANDLER | — | — | Should | — |
DATENLOGGER | — | — | Should | — |
KOMMUNIKATIONSANSCHLUSS | — | — | Should | — |
MODEM | — | — | Should | — |
TELEKOMMUNIKATIONSEINRICHTUNG | — | — | Should | — |
KOMMUNIKATIONSEINRICHTUNG | — | — | Should | — |
DREHKOLBENGASZAEHLER | — | — | Should | — |
TURBINENRADGASZAEHLER | — | — | Should | — |
ULTRASCHALLZAEHLER | — | — | Should | — |
WIRBELGASZAEHLER | — | — | Should | — |
MODERNE_MESSEINRICHTUNG | — | — | Should | — |
ELEKTRONISCHER_HAUSHALTSZAEHLER | — | — | Should | — |
STEUEREINRICHTUNG | — | — | Should | — |
TECHNISCHESTEUEREINRICHTUNG | — | — | Should | — |
TARIFSCHALTGERAET | — | — | Should | — |
RUNDSTEUEREMPFAENGER | — | — | Should | — |
OPTIONALE_ZUS_ZAEHLEINRICHTUNG | — | — | Should | — |
MESSWANDLERSATZ_IMS_MME | — | — | Should | — |
KOMBIMESSWANDLER_IMS_MME | — | — | Should | — |
TARIFSCHALTGERAET_IMS_MME | — | — | Should | — |
RUNDSTEUEREMPFAENGER_IMS_MME | — | — | Should | — |
TEMPERATUR_KOMPENSATION | — | — | Should | — |
HOECHSTBELASTUNGS_ANZEIGER | — | — | Should | — |
SONSTIGES_GERAET | — | — | Should | — |
SMARTMETERGATEWAY | — | — | Should | — |
STEUERBOX | — | — | Should | — |
BLOCKSTROMWANDLER | — | — | Should | — |
KOMBIMESSWANDLER | — | — | Should | — |
MODEM_GSM | — | — | Should | — |
ETHERNET_KOM | — | — | Should | — |
PLC_COM | — | — | Should | — |
MODEM_FESTNETZ | — | — | Should | — |
DSL_KOM | — | — | Should | — |
LTE_KOM | — | — | Should | — |
DICHTEMENGENUMWERTER | — | — | Should | — |
TEMPERATURMENGENUMWERTER | — | — | Should | — |
ZUSTANDSMENGENUMWERTER | — | — | Should | — |
MESSDATENREGISTRIERGERAET | — | — | Should | — |
WANDLER | — | — | Should | — |
BEFESTIGUNGSEINRICHTUNG | — | — | Should | — |
| weitereGeraetenummern 00310 | weitereGeraetenummern | array | X | — |
| geraeteeigenschaften | — | object | May | — |
| faktor 00320 | faktor | number (float) | Must | — |
| geraetemerkmal 00330 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| gueltigkeitszeitraum | — | object | May | — |
| zeitraumId 00340 | zeitraumId | integer | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| bezeichnung 00350 | Additional designation, e.g. Zählwerk_Wirkarbeit. | string | Must | — |
| konfiguration 00360 | Configuration (iMSys) of the meter register | string | X | — |
| nachkommastelle 00370 | nachkommastelle | integer | Must | — |
| obisKennzahl 00380 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| vorkommastelle 00390 | vorkommastelle | integer | Must | — |
| wertegranularitaet 00400 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| zaehlzeiten | — | object | May | — |
| register 00410 | Metering time period register | string | X | — |
| zaehlzeitDefinition 00420 | Metering time period definition | string | X | — |
| transaktionsdaten * | — | object | Must | — |
| dokumentennummer * 00430 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| kategorie * 00440 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 00450 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00460 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00470 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 00480 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vorgangsnummer * 00490 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00500 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00510 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00520 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00530 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55653 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0300070 | Change notifications | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document-/ message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document/message issuer or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00160 | Message recipient | — | X | — |
303900170 | MP-ID | — | X | — |
3055 900180 | GS1 | — | X | — |
3055 29300190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400200 | Transaction | — | X | — |
740200210 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700220 | Transaction reason | — | X | — |
9013 ZX700230 | Change data of the MeLo | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1700240 | Metering location | — | X | — |
322500250 | ID of the metering location | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300260 | Check identifier | — | X | — |
1154 5565300270 | GPKE / Change data of the MeLo from MSB to LF | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 Z4900280 | Valid data | — | X | [1P0..n] |
1153 Z5300290 | No data | — | X | [1P0..n] |
115600300 | Time period ID | — | X | [914] ∧ [937] [126] |
| SG6.DTM | — | — | Must | [131] ⊻ [401] |
2005 Z2500310 | Data used from | — | X | — |
238000320 | Date or time or time span, value | — | X | [UB1] |
2379 30300330 | CCYYMMDDHHMMZZZ | — | X | — |
| SG6.DTM | — | — | Must | [471] |
2005 Z2600340 | Data used until | — | X | — |
238000350 | Date or time or time span, value | — | X | [UB1] |
2379 30300360 | CCYYMMDDHHMMZZZ | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1800370 | Data of the metering location | — | X | — |
105000380 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG10.CCI | — | — | Must | — |
7037 E0400390 | Voltage level of the metering location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0300400 | Extra-high voltage | — | X | — |
7111 E0400410 | High voltage | — | X | — |
7111 E0500420 | Medium voltage | — | X | — |
7111 E0600430 | Low voltage | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0300440 | Metering device data | — | X | — |
105000450 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG8.RFF | — | — | Should | [166] ∧ [215] |
1153 Z1400460 | Smart meter gateway | — | X | — |
115400470 | Identification / number of the smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1300480 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AHZ00490 | analog household meter (three-phase current) | — | X | — |
7111 WSZ00500 | analog alternating current meter | — | X | — |
7111 LAZ00510 | Load curve meter | — | X | — |
7111 MAZ00520 | Maximum demand meter | — | X | — |
7111 MME00530 | modern metering device according to MsbG | — | X | — |
7111 EHZ00540 | electronic household meter | — | X | — |
7111 IVA00550 | Individual reconciliation (special equipment) | — | X | — |
7110 Z0100560 | EDL40 | — | X | [136] |
7110 Z0200570 | EDL21 | — | X | [136] |
7110 Z0300580 | other EHZ | — | X | [136] |
7110 Z0400590 | Standard | — | X | [346] |
7110 Z0500600 | MeDa meter | — | X | [346] |
| SG10.CAV | — | — | Must | — |
7111 Z3000610 | Device number | — | X | — |
711000620 | Device number | — | X | — |
| SG10.CAV | — | — | Must | [139] |
7111 ETZ00630 | Single tariff | — | X | — |
7111 ZTZ00640 | Two-tariff | — | X | — |
7111 NTZ00650 | Multi-tariff | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ERZ00660 | Single-direction meter | — | X | — |
7111 ZRZ00670 | Bidirectional meter | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2000680 | OBIS data of the metering device | — | X | — |
105000690 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG8.RFF | — | — | Must | [665] |
1153 MG00700 | Device number of the meter | — | X | [204] |
1153 Z1400710 | Smart meter gateway | — | X | — |
115400720 | Device number | — | X | — |
| SG8.RFF | — | — | Must | [402] ∧ [420] |
1153 AGK00730 | Application reference number | — | X | — |
115400740 | Reference, identification | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 500750 | Product identification | — | X | — |
714000760 | OBIS code of the metering device | — | X | [323] |
7143 SRW00770 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE400780 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD900790 | Annually | — | X | — |
7111 ZE800800 | Semi-annual | — | X | — |
7111 ZE900810 | Quarterly | — | X | — |
7111 ZB700820 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3900830 | Code of the metering time period definition | — | X | — |
703700840 | Code of the metering time period definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3800850 | Code of the metering time period register | — | X | — |
703700860 | Code of the metering time period register | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1100870 | Product | — | X | — |
7037 Z3300880 | Integer and decimal places of the register | — | X | — |
| SG10.CAV | — | — | Must | — |
711000890 | Digits before the decimal point | — | X | — |
711000900 | Digits after the decimal point | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6300910 | Local identifier for control purposes | — | X | — |
703600920 | Designation of the register on the device | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0400930 | Instrument transformer data | — | X | — |
105000940 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG8.RFF | — | — | Must | — |
1153 MG00950 | Device number of the meter | — | X | — |
115400960 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2500970 | Instrument transformer | — | X | — |
| SG10.CAV | — | — | Must | [2317] ⊻ [2318] |
7111 Z3000980 | Device number | — | X | — |
711000990 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 MIW01000 | Current transformer set | — | X | — |
7111 MPW01010 | Combined instrument transformer set (current and voltage) | — | X | — |
7111 MBW01020 | Block current transformer | — | X | — |
7111 MUW01030 | Voltage transformer set | — | X | — |
711001040 | Instrument transformer factor | — | X | [902] [141] |
| SG8.SEQ | — | — | Must | — |
1229 Z1301050 | Smart meter gateway | — | X | — |
105001060 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG10.CCI | — | — | Must | — |
7037 Z7501070 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3001080 | Device number | — | X | — |
711001090 | Device number | — | X | [952] |
| SG12.NAD | — | — | Must | — |
3035 Z0501100 | Name and address for the meter reading card | — | X | — |
303601110 | Name | — | X | — |
3045 Z0101120 | Structure of person names | — | X | — |
3045 Z0201130 | Structure of the company name | — | X | — |
304201140 | Street and house number or PO box | — | X | — |
316401150 | City | — | X | — |
325101160 | Postal code | — | — | M [268] S [166] |
320701170 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z4601180 | Reference to time period ID | — | X | — |
115401190 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| UNT | — | — | Must | — |
007401200 | Number of segments in a message | — | X | — |
006201210 | Message reference number | — | X | — |
Conditions of this table
The free text of the 28 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [22] | The time period ID from DE1156 of a matching SG6 RFF+Z47/Z48/Z49 (usage period of the data) must be entered |
| [126] | The value resulting from the number of repetitions of the SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) must be entered. This means: the first SG6 RFF+Z49/Z53 thus has the „1“, the second the „2“, the third the „3“, etc. |
| [131] | If this DTM+Z25 (use of the data from) in SG6 RFF (usage peri od of the data) is marked with the time period ID "1" in DE1156, the date in this DE2380 must be the day immediately following DTM+137 DE2380 (message dat e) at 0:00, or a day earlier than that at 0:00 German time |
| [136] | If SG10 CCI+++E13 (meter type) CAV+EHZ (electronic household meter) present in this SG8 |
| [139] | If SG10 CAV+IVA (individual reconciliation) not present in this SG8 |
| [141] | If SG10 CAV+MIW/MPW/MBW present |
| [166] | If present |
| [204] | If RFF+Z14 (reference to the smart meter gateway) is not present in the SG8+SEQ+Z03/ZA3/ZA4 (metering device data) with the same time period ID in the SG8 SEQ DE1050 and with identical quality in DE1229 of the SG8 SEQ, for the device number of a meter named in this RFF DE1154 |
| [215] | If in the same SG8 (metering device data) SG10 CCI+++E13 CAV+MME (meter type: mME) is present |
| [268] | If an "X" is listed for the code in DE3207 in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| [323] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3., that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document "Code list of configurations" |
| [346] | If SG10 CCI+++E13 (meter type) CAV+MME (mME) present in this SG8 |
| [401] | If this DTM+Z25 (use of data from) is not in the SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) with time period ID "1" in DE1156, the date must correspond to the DTM+Z26 (use of data until) of the SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) with the next lower time period ID in DE1156 |
| [402] | If in the same SG8 (OBIS data of the metering device / smart meter gateway) an OBIS code of the value type "meter reading" is present in the PIA+5 |
| [420] | If the RFF+Z14 (smart meter gateway) is present in this SG8 |
| [471] | If a time period ID is named in DE1156 (time period ID) in the same SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) which is lower than in another SG6 RFF+Z49/Z53 (usage period of the data: valid data/no data) DE1156 (time period ID) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [665] | Note: If a meter is parameterized with a SMGW, no OBIS code numbers are stated for that meter. Only OBIS code numbers from the SMGW exist here |
| [902] | Format: Possible value: ≥ 0 |
| [914] | Format: Possible value: > 0 |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [2317] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MIW/MPW/MUW is present, the segment must be specified at least twice |
| [2318] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MBW (block current transformer ) is present, the segment must be specified exactly once |
| [1P0..n] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
Example message
UNA:+.? '
UNB+UNOC:3+9900496000001:500+9900496000002:500+{{date}}:{{time}}+M3KZJRZH'
UNH+UNHM35S7BK0+UTILMD:D:11A:UN:S2.2'
BGM+E03+BGMM3O37Z21'
DTM+137:202610021100?+00:303'
NAD+MS+9900496000001::293'
NAD+MR+9900496000002::293'
IDE+24+KBG27094210000000000929931413171000'
STS+7++ZX7'
LOC+Z17+DE0032106765712000000000000001217'
RFF+Z13:55653'
RFF+Z49::1'
DTM+Z25:202412312300?+00:303'
SEQ+Z18+1'
CCI+++E04'
CAV+E06'
SEQ+Z03+1'
RFF+Z14:1LGZ0061572222'
CCI+++E13'
CAV+MME:::Z04'
CAV+Z30:::1LGZ0061578888'
CAV+ZTZ'
CAV+ERZ'
SEQ+Z20+1'
RFF+Z14:1LGZ0061572222'
RFF+AGK:34590456ujdfsdghdlktztwqq-053brt'
PIA+5+1-0?:1.8.1:SRW'
CCI+++ZE4'
CAV+ZD9'
CCI+Z39++ABV'
CCI+Z38++ABD'
CCI+11++Z33'
CAV+:::7:3'
CCI+++Z63:::1'
SEQ+Z20+1'
RFF+Z14:1LGZ0061572222'
RFF+AGK:34590456ujdfsdghdlktztwqq-053art'
PIA+5+1-0?:1.8.2:SRW'
CCI+++ZE4'
CAV+ZD9'
CCI+Z39++ABV'
CCI+Z38++ABD'
CCI+11++Z33'
CAV+:::7:3'
CCI+++Z63:::2'
SEQ+Z04+1'
RFF+MG:1LGZ0061578888'
CCI+++Z25'
CAV+Z30:::1LGZ0061578000'
CAV+Z30:::1LGZ0061579000'
CAV+MIW:::1'
SEQ+Z04+1'
RFF+MG:1LGZ0061578888'
CCI+++Z25'
CAV+Z30:::1LGZ0061578001'
CAV+Z30:::1LGZ0061579001'
CAV+MIW:::1'
SEQ+Z13+1'
CCI+++Z75'
CAV+Z30:::1LGZ0061572222'
NAD+Z05+++Max:Mustermann::::Z02+Erfurter Str.:46+Weimar++99423+DE'
RFF+Z46:1'
UNT+61+UNHM35S7BK0'
UNZ+1+M3KZJRZH'[1 item
{6 fields
"data": {3 fields
"stammdaten": {3 fields
"VERWENDUNGSZEITRAUM": [1 item
{5 fields
"MESSLOKATION": [1 item
{8 fields
"gueltigkeitszeitraum": {2 fields
"ablesekartenempfaenger": {7 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {5 fields
"ZAEHLER": [1 item
{13 fields
"gueltigkeitszeitraum": {2 fields
"zaehlwerke": [2 items
{7 fields
"zaehlzeiten": {2 fields
{7 fields
"zaehlzeiten": {2 fields
"geraete": [3 items
{3 fields
"weitereGeraetenummern": [1 item
"geraeteeigenschaften": {3 fields
{3 fields
"weitereGeraetenummern": [1 item
"geraeteeigenschaften": {3 fields
{2 fields
"geraeteeigenschaften": {1 field
"transaktionsdaten": {11 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ÜNB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Master data change initiated by the MSB (responsible) | GPKE part 4 | Electricity | Step 4 |
| NB | NB | Master data change initiated by the MSB (responsible) | GPKE part 4 | Electricity | Step 4 |
| MSB | MSB | Master data change initiated by the MSB (responsible) | GPKE part 4 | Electricity | Step 4 |
| MSB | WMSB | Master data change initiated by the MSB (responsible) | GPKE part 4 | Electricity | Step 4 |
| ÜNB | ÜNB | Master data change initiated by the MSB (responsible) | GPKE part 4 | Electricity | Step 4 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Change data of the MeLo |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 4 | Master data change initiated by the MSB (responsible) | MSB → LF | Change from the MSB to LF |
Transaction and responses
Role of this check identifier: request. Basis: the transaction data carry neither antwortstatus nor antwortstatusCodeliste, and neither the title nor the action of the Prüfi table begins with “response” or “response message”.
Responses: No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 165 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type utilmd. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.