Check identifier 55169 — Confirmation of commitment request
Check identifier 55169 · EDIFACT message type UTILMD · Format version 202610
Data structure
| Structure (BO4E) | Description | Format | 55169 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| BILANZIERUNG [ ] | — | object[] | May | — |
| abwicklungsmodell 00010 | Processing model | Enum Abwicklungsmodell | Must | — |
MODELL_1_BILANZIERUNG_AN_MARKTLOKATION | — | — | Must | — |
MODELL_2_BILANZIERUNG_IM_BILANZIERUNGSGEBIET | — | — | Must | — |
| aggregationsverantwortung 00020 | Aggregation responsibility | Enum Aggregationsverantwortung | X | — |
UENB | — | — | X | — |
VNB | — | — | X | — |
| detailsPrognosegrundlage 00030 | Forecast basis - If a day-parameter-dependent load profile with joint metering has to be specified, this is possible by repeating the CAV segment twice, stating the codes E02 and E14. | array | Must | — |
| marktlokationsId 00040 | Which market location these balancing data apply to | string | X | — |
| prognosegrundlage 00050 | Forecast basis | Enum Prognosegrundlage | Must | — |
WERTE | — | — | Must | — |
PROFILE | — | — | Must | — |
| jahresverbrauchsprognose | — | object | May | — |
| einheit 00060 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 00070 | Value | number (float) | X | — |
| lastprofile [ ] | — | object[] | May | — |
| bezeichnung 00080 | Designation of the profile | string | Must | — |
| einspeisung 00090 | Feed-in indicator | boolean | Must | — |
| profilart 00100 | Profile category | Enum Profilart | Must | — |
ART_STANDARDLASTPROFIL | — | — | Must | — |
ART_TAGESPARAMETERABHAENGIGES_LASTPROFIL | — | — | Must | — |
ART_LASTPROFIL | — | — | Must | — |
| referenzprofilbezeichnung 00110 | Designation of the reference profile | string | Must | — |
| verfahren 00120 | Profiling method | Enum Profilverfahren | Must | — |
SYNTHETISCH | — | — | Must | — |
ANALYTISCH | — | — | Must | — |
| tagesparameter | — | object | May | — |
| dienstanbieter 00130 | dienstanbieter | string | Must | — |
| herausgeber 00140 | Herausgeber | Enum Herausgeber | Must | — |
NB | — | — | Must | — |
BDEW | — | — | Must | — |
TUM | — | — | Must | — |
| klimazone 00150 | klimazone | string | Must | — |
| temperaturmessstelle 00160 | temperaturmessstelle | string | Must | — |
| temperaturarbeit | — | object | May | — |
| einheit 00170 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | Must | — |
W | — | — | Must | — |
WH | — | — | Must | — |
KW | — | — | Must | — |
KWH | — | — | Must | — |
KVARH | — | — | Must | — |
MW | — | — | Must | — |
MWH | — | — | Must | — |
STUECK | — | — | Must | — |
KUBIKMETER | — | — | Must | — |
STUNDE | — | — | Must | — |
TAG | — | — | Must | — |
MONAT | — | — | Must | — |
JAHR | — | — | Must | — |
PROZENT | — | — | Must | — |
ANZAHL | — | — | Must | — |
VAR | — | — | Must | — |
KVAR | — | — | Must | — |
VARH | — | — | Must | — |
KWHK | — | — | Must | — |
Z16 | — | — | Must | — |
KWT | — | — | Must | — |
WATT_PRO_QUADRATMETER | — | — | Must | — |
METER_PRO_SEKUNDE | — | — | Must | — |
| wert 00180 | Value | number (float) | Must | — |
| ENERGIELIEFERVERTRAG [ ] | — | object[] | May | — |
| lokationsId 00190 | lokationsId | string | X | — |
| korrespondenzpartner | — | object | May | — |
| anrede 00200 | The form of address for the GePa, e.g. Mr. | string | X | — |
| name1 00210 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00220 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00230 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00240 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 00250 | House number and supplement | string | X | — |
| landescode 00260 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00270 | City | string | X | — |
| ortsteil 00280 | District | string | X | — |
| postfach 00290 | PO box | string | X | — |
| postleitzahl 00300 | Postal code | string | X | — |
| strasse 00310 | Street | string | X | — |
| vertragspartner2 [ ] | — | object[] | May | — |
| anrede 00320 | The form of address for the GePa, e.g. Mr. | string | X | — |
| geschaeftspartnerrolle 00330 | Role held by the business partner (e.g. prospect, customer). | array | X | — |
| name1 00340 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00350 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00360 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00370 | name4 | string | X | — |
| LOKATIONSBUENDEL [ ] * | — | object[] | Must | — |
| lokationsbuendelNummer 00380 | lokationsbuendelNummer | integer | Must | — |
| lokationsbuendelstrukturId 00390 | lokationsbuendelstrukturId | string | Must | — |
| standardisierteLokationsbuendelstruktur * 00400 | standardisierteLokationsbuendelstruktur | boolean | Must | — |
| zuordnungObjectcode [ ] | — | object[] | May | — |
| referenzLokationsId 00410 | referenzLokationsId | string | Must | — |
| referenzLokationsTyp 00420 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| referenzMarktlokationTechnischeRessource 00430 | referenzMarktlokationTechnischeRessource | array | X | — |
| vorgelagerteLokationId 00440 | vorgelagerteLokationId | string | Must | — |
| vorgelagerteLokationTyp 00450 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | Must | — |
MALO | — | — | Must | — |
MELO | — | — | Must | — |
NELO | — | — | Must | — |
TECHNISCHE_RESSOURCE | — | — | Must | — |
STEUERBARE_RESSOURCE | — | — | Must | — |
TRANCHE | — | — | Must | — |
MABIS_ZAEHLPUNKT | — | — | Must | — |
| objectcode [ ] | — | object[] | May | — |
| lokationsbuendelNummer 00460 | lokationsbuendelNummer | integer | X | — |
| objectcode 00470 | objectcode | string | X | — |
| MARKTLOKATION [ ] * | — | object[] | Must | — |
| energierichtung 00480 | Indicates whether energy is fed in or drawn (fed out). | Enum Energierichtung | X | — |
AUSSP | — | — | X | — |
EINSP | — | — | X | — |
| marktlokationsId * 00490 | Identification number of a market location at which energy is either consumed or generated | string | X | — |
| messtechnischeEinordnung 00500 | Metering classification from the UTILMD (IMS, KME_MME, KEINE_MESSUNG) | Enum MesstechnischeEinordnung | Must | — |
IMS | — | — | Must | — |
KME_MME | — | — | Must | — |
KEINE_MESSUNG | — | — | Must | — |
| netzebene 00510 | Grid level at which the energy is drawn. For electricity, the voltage level of the supply; for gas, the pressure level. Example electricity: low voltage Example gas: low pressure. | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| energieherkunft [ ] | — | object[] | May | — |
| erzeugungsart 00520 | Type of generation | Enum Erzeugungsart | Must | — |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00530 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00540 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00550 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00560 | weiterverpflichtet | boolean | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 00570 | messprodukt | string | X | — |
| obisKennzahl 00580 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| verwendungszweckLF 00590 | Codes according to the code list of the purposes of use Purpose of use LF | string | X | — |
| verwendungszweckNB 00600 | Codes according to the code list of the purposes of use Purpose of use NB | string | X | — |
| verwendungszweckUENB 00610 | Codes according to the code list of the purposes of use Purpose of use ÜNB | string | X | — |
| wertegranularitaet 00620 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| zaehlzeiten | — | object | May | — |
| register 00630 | Metering time period register | string | X | — |
| zaehlzeitDefinition 00640 | Metering time period definition | string | X | — |
| MESSLOKATION [ ] * | — | object[] | Must | — |
| betriebszustand 00650 | Operating state | Enum Betriebszustand | X | — |
GESPERRT_NICHT_ENTSPERREN | — | — | X | — |
GESPERRT | — | — | X | — |
REGELBETRIEB | — | — | X | — |
AUSSERHALB_REGELBETRIEB | — | — | X | — |
| datenqualitaet 00660 | Data quality | Enum Datenqualitaet | X | — |
ERWARTETE_DATEN | — | — | X | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | X | — |
INFORMATIVE_DATEN | — | — | X | — |
GUELTIGE_DATEN | — | — | X | — |
KEINE_DATEN | — | — | X | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | X | — |
KEINE_DATEN_ERWARTET | — | — | X | — |
DIFFERENZ_DATEN | — | — | X | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | X | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | X | — |
| messlokationsId * 00670 | The metering location identification. This is the former metering point identifier, e.g. DE 47108151234567 | string | X | — |
| netzebenemessung 00680 | Grid level | Enum Netzebene | Must | — |
NSP | — | — | Must | — |
MSP | — | — | Must | — |
HSP | — | — | Must | — |
HSS | — | — | Must | — |
MSP_NSP_UMSP | — | — | Must | — |
HSP_MSP_UMSP | — | — | Must | — |
HSS_HSP_UMSP | — | — | Must | — |
HD | — | — | Must | — |
MD | — | — | Must | — |
ND | — | — | Must | — |
| referenzMarktlokationsId 00690 | referenzMarktlokationsId | string | X | — |
| verwendungsumfang 00700 | Scope of use | Enum Verwendungsumfang | X | — |
MESSLOKATION_PROZESSUAL_BEHANDELT | — | — | X | — |
MESSLOKATION_LOKATIONSBUENDEL | — | — | X | — |
| ablesekartenempfaenger * | — | object | Must | — |
| anrede 00710 | The form of address for the GePa, e.g. Mr. | string | X | — |
| gewerbekennzeichnung 00720 | Indicates whether this is a business/company (gewerbeKennzeichnung = true) or a private individual. (gewerbeKennzeichnung = false) | boolean | X | — |
| name1 * 00730 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 00740 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 00750 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 00760 | name4 | string | X | — |
| partneradresse | — | object | May | — |
| hausnummer 00770 | House number and supplement | string | X | — |
| landescode 00780 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00790 | City | string | X | — |
| ortsteil 00800 | District | string | X | — |
| postfach 00810 | PO box | string | X | — |
| postleitzahl 00820 | Postal code | string | X | — |
| strasse 00830 | Street | string | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 00840 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 00850 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 00860 | Specifies the code value of the market role. | string | X | — |
| weiterverpflichtet 00870 | weiterverpflichtet | boolean | X | — |
| messadresse | — | object | May | — |
| hausnummer 00880 | House number and supplement | string | X | — |
| landescode 00890 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 00900 | City | string | X | — |
| ortsteil 00910 | District | string | X | — |
| postfach 00920 | PO box | string | X | — |
| postleitzahl 00930 | Postal code | string | X | — |
| strasse 00940 | Street | string | X | — |
| zusatzInformation | — | object | May | — |
| zusatz1 00950 | Address supplement 1 | string | X | — |
| zusatz2 00960 | Address supplement 2 | string | X | — |
| zusatz3 00970 | Address supplement 3 | string | X | — |
| zusatz4 00980 | Address supplement 4 | string | X | — |
| zusatz5 00990 | Address supplement 5 | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 01000 | messprodukt | string | X | — |
| notwendigkeitZweiteMessung 01010 | Necessity of second measurement | Enum NotwendigkeitZweiteMessung | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| werteuebermittlungVerwendungszweck 01020 | Purpose of use for value transmission | Enum WerteuebermittlungVerwendungszweck | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| zaehlzeiten | — | object | May | — |
| zaehlzeitDefinition 01030 | Metering time period definition | string | Must | — |
| MESSSTELLENBETRIEBSVERTRAG [ ] * | — | object[] | Must | — |
| lokationsId * 01040 | lokationsId | string | X | — |
| lokationsTyp * 01050 | Indicates whether it is a market location or a metering location | Enum Lokationstyp | X | — |
MALO | — | — | X | — |
MELO | — | — | X | — |
NELO | — | — | X | — |
TECHNISCHE_RESSOURCE | — | — | X | — |
STEUERBARE_RESSOURCE | — | — | X | — |
TRANCHE | — | — | X | — |
MABIS_ZAEHLPUNKT | — | — | X | — |
| korrespondenzpartner * | — | object | Must | — |
| anrede 01060 | The form of address for the GePa, e.g. Mr. | string | X | — |
| name1 * 01070 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 01080 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 01090 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 01100 | name4 | string | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 01110 | Email address | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 01120 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 01130 | rufnummer | string | Must | — |
| partneradresse | — | object | May | — |
| hausnummer 01140 | House number and supplement | string | X | — |
| landescode 01150 | Country code | Enum Landescode | X | — |
AC | — | — | X | — |
AD | — | — | X | — |
AE | — | — | X | — |
AF | — | — | X | — |
AG | — | — | X | — |
AI | — | — | X | — |
AL | — | — | X | — |
AM | — | — | X | — |
AN | — | — | X | — |
AO | — | — | X | — |
AQ | — | — | X | — |
AR | — | — | X | — |
AS | — | — | X | — |
AT | — | — | X | — |
AU | — | — | X | — |
AW | — | — | X | — |
AX | — | — | X | — |
AZ | — | — | X | — |
BA | — | — | X | — |
BB | — | — | X | — |
BD | — | — | X | — |
BE | — | — | X | — |
BF | — | — | X | — |
BG | — | — | X | — |
BH | — | — | X | — |
BI | — | — | X | — |
BJ | — | — | X | — |
BL | — | — | X | — |
BM | — | — | X | — |
BN | — | — | X | — |
BO | — | — | X | — |
BQ | — | — | X | — |
BR | — | — | X | — |
BS | — | — | X | — |
BT | — | — | X | — |
BU | — | — | X | — |
BV | — | — | X | — |
BW | — | — | X | — |
BY | — | — | X | — |
BZ | — | — | X | — |
CA | — | — | X | — |
CC | — | — | X | — |
CD | — | — | X | — |
CF | — | — | X | — |
CG | — | — | X | — |
CH | — | — | X | — |
CI | — | — | X | — |
CK | — | — | X | — |
CL | — | — | X | — |
CM | — | — | X | — |
CN | — | — | X | — |
CO | — | — | X | — |
CP | — | — | X | — |
CR | — | — | X | — |
CS | — | — | X | — |
CU | — | — | X | — |
CV | — | — | X | — |
CW | — | — | X | — |
CX | — | — | X | — |
CY | — | — | X | — |
CZ | — | — | X | — |
DE | — | — | X | — |
DG | — | — | X | — |
DJ | — | — | X | — |
DK | — | — | X | — |
DM | — | — | X | — |
DO | — | — | X | — |
DZ | — | — | X | — |
EA | — | — | X | — |
EC | — | — | X | — |
EE | — | — | X | — |
EG | — | — | X | — |
EH | — | — | X | — |
ER | — | — | X | — |
ES | — | — | X | — |
ET | — | — | X | — |
EU | — | — | X | — |
FI | — | — | X | — |
FJ | — | — | X | — |
FK | — | — | X | — |
FM | — | — | X | — |
FO | — | — | X | — |
FR | — | — | X | — |
FX | — | — | X | — |
GA | — | — | X | — |
GB | — | — | X | — |
GD | — | — | X | — |
GE | — | — | X | — |
GF | — | — | X | — |
GG | — | — | X | — |
GH | — | — | X | — |
GI | — | — | X | — |
GL | — | — | X | — |
GM | — | — | X | — |
GN | — | — | X | — |
GP | — | — | X | — |
GQ | — | — | X | — |
GR | — | — | X | — |
GS | — | — | X | — |
GT | — | — | X | — |
GU | — | — | X | — |
GW | — | — | X | — |
GY | — | — | X | — |
HK | — | — | X | — |
HM | — | — | X | — |
HN | — | — | X | — |
HR | — | — | X | — |
HT | — | — | X | — |
HU | — | — | X | — |
IC | — | — | X | — |
ID | — | — | X | — |
IE | — | — | X | — |
IL | — | — | X | — |
IM | — | — | X | — |
IN | — | — | X | — |
IO | — | — | X | — |
IQ | — | — | X | — |
IR | — | — | X | — |
IS | — | — | X | — |
IT | — | — | X | — |
JE | — | — | X | — |
JM | — | — | X | — |
JO | — | — | X | — |
JP | — | — | X | — |
KE | — | — | X | — |
KG | — | — | X | — |
KH | — | — | X | — |
KI | — | — | X | — |
KM | — | — | X | — |
KN | — | — | X | — |
KP | — | — | X | — |
KR | — | — | X | — |
KW | — | — | X | — |
KY | — | — | X | — |
KZ | — | — | X | — |
LA | — | — | X | — |
LB | — | — | X | — |
LC | — | — | X | — |
LI | — | — | X | — |
LK | — | — | X | — |
LR | — | — | X | — |
LS | — | — | X | — |
LT | — | — | X | — |
LU | — | — | X | — |
LV | — | — | X | — |
LY | — | — | X | — |
MA | — | — | X | — |
MC | — | — | X | — |
MD | — | — | X | — |
ME | — | — | X | — |
MF | — | — | X | — |
MG | — | — | X | — |
MH | — | — | X | — |
MK | — | — | X | — |
ML | — | — | X | — |
MM | — | — | X | — |
MN | — | — | X | — |
MO | — | — | X | — |
MP | — | — | X | — |
MQ | — | — | X | — |
MR | — | — | X | — |
MS | — | — | X | — |
MT | — | — | X | — |
MU | — | — | X | — |
MV | — | — | X | — |
MW | — | — | X | — |
MX | — | — | X | — |
MY | — | — | X | — |
MZ | — | — | X | — |
NA | — | — | X | — |
NC | — | — | X | — |
NE | — | — | X | — |
NF | — | — | X | — |
NG | — | — | X | — |
NI | — | — | X | — |
NL | — | — | X | — |
NO | — | — | X | — |
NP | — | — | X | — |
NR | — | — | X | — |
NT | — | — | X | — |
NU | — | — | X | — |
NZ | — | — | X | — |
OM | — | — | X | — |
PA | — | — | X | — |
PE | — | — | X | — |
PF | — | — | X | — |
PG | — | — | X | — |
PH | — | — | X | — |
PK | — | — | X | — |
PL | — | — | X | — |
PM | — | — | X | — |
PN | — | — | X | — |
PR | — | — | X | — |
PS | — | — | X | — |
PT | — | — | X | — |
PW | — | — | X | — |
PY | — | — | X | — |
QA | — | — | X | — |
RE | — | — | X | — |
RO | — | — | X | — |
RS | — | — | X | — |
RU | — | — | X | — |
RW | — | — | X | — |
SA | — | — | X | — |
SB | — | — | X | — |
SC | — | — | X | — |
SD | — | — | X | — |
SE | — | — | X | — |
SF | — | — | X | — |
SG | — | — | X | — |
SH | — | — | X | — |
SI | — | — | X | — |
SJ | — | — | X | — |
SK | — | — | X | — |
SL | — | — | X | — |
SM | — | — | X | — |
SN | — | — | X | — |
SO | — | — | X | — |
SR | — | — | X | — |
SS | — | — | X | — |
ST | — | — | X | — |
SU | — | — | X | — |
SV | — | — | X | — |
SX | — | — | X | — |
SY | — | — | X | — |
SZ | — | — | X | — |
TA | — | — | X | — |
TC | — | — | X | — |
TD | — | — | X | — |
TF | — | — | X | — |
TG | — | — | X | — |
TJ | — | — | X | — |
TK | — | — | X | — |
TL | — | — | X | — |
TM | — | — | X | — |
TN | — | — | X | — |
TO | — | — | X | — |
TP | — | — | X | — |
TR | — | — | X | — |
TT | — | — | X | — |
TV | — | — | X | — |
TW | — | — | X | — |
TZ | — | — | X | — |
UA | — | — | X | — |
UG | — | — | X | — |
UK | — | — | X | — |
UM | — | — | X | — |
US | — | — | X | — |
UY | — | — | X | — |
UZ | — | — | X | — |
VA | — | — | X | — |
VC | — | — | X | — |
VE | — | — | X | — |
VG | — | — | X | — |
VI | — | — | X | — |
VN | — | — | X | — |
VU | — | — | X | — |
WF | — | — | X | — |
WS | — | — | X | — |
XK | — | — | X | — |
YE | — | — | X | — |
YT | — | — | X | — |
YU | — | — | X | — |
ZA | — | — | X | — |
ZM | — | — | X | — |
ZR | — | — | X | — |
ZW | — | — | X | — |
| ort 01160 | City | string | X | — |
| ortsteil 01170 | District | string | X | — |
| postfach 01180 | PO box | string | X | — |
| postleitzahl 01190 | Postal code | string | X | — |
| strasse 01200 | Street | string | X | — |
| vertragskonditionen | — | object | May | — |
| geplanteTurnusablesung | — | object | May | — |
| ableseZeitraum 01210 | ableseZeitraum | string | X | — |
| vertragspartner2 [ ] * | — | object[] | Must | — |
| anrede 01220 | The form of address for the GePa, e.g. Mr. | string | X | — |
| geschaeftspartnerrolle 01230 | Role held by the business partner (e.g. prospect, customer). | array | X | — |
| name1 * 01240 | First part of the name. This can hold the company name or, for private individuals, the surname, for example. Examples: Yellow Strom GmbH or Hagen | string | X | — |
| name2 01250 | Second part of the name. Here an extension to the company name or for private individuals, for example, the first name can be entered. Examples: Bereich Süd or Nina | string | X | — |
| name3 01260 | Third part of the name. Further additions to the company name or , for private individuals, additions to the name can be represented here. Examples: and Africa or singer | string | X | — |
| name4 01270 | name4 | string | X | — |
| NETZLOKATION [ ] | — | object[] | May | — |
| konfigurationsprodukt 01280 | konfigurationsprodukt | string | X | — |
| leistungskurvendefinition 01290 | Code of the assigned power curve definition for the object | string | X | — |
| netzlokationsId 01300 | Identification number of a grid location at which energy is either consumed or generated (like MarktlokationsId market location) | string | X | — |
| produktdatenRelevanteRolle 01310 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| steuerkanal 01320 | Whether a control channel is assigned to the grid location and the grid location can therefore be controlled. ZF2: No control channel present ZF3: Control channel present | boolean | X | — |
| auftraggebenderMarktpartner | — | object | May | — |
| marktrolle 01330 | Indicates the designation of the market role in free text. | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| rollencodenummer 01340 | Specifies the code value of the market role. | string | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 01350 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 01360 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 01370 | Specifies the code value of the market role. | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| keinProdukt 01380 | CCI+11++ZF6: no product assigned | boolean | X | — |
| obisKennzahl 01390 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| verwendungszweckLF 01400 | Codes according to the code list of the purposes of use Purpose of use LF | string | X | — |
| verwendungszweckNB 01410 | Codes according to the code list of the purposes of use Purpose of use NB | string | X | — |
| STEUERBARE_RESSOURCE [ ] | — | object[] | May | — |
| keinKonfigurationsprodukt 01420 | keinKonfigurationsprodukt | boolean | X | — |
| konfigurationsprodukt 01430 | konfigurationsprodukt | string | X | — |
| produktdatenRelevanteRolle 01440 | A market participant can take on these roles | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| ressourcenId 01450 | ressourcenId | string | X | — |
| steuerkanal 01460 | Control channel | Enum Steuerkanal | X | — |
AN_AUS | — | — | X | — |
GESTUFT | — | — | X | — |
| auftraggebenderMarktpartner | — | object | May | — |
| marktrolle 01470 | Indicates the designation of the market role in free text. | Enum Marktrolle | Must | — |
NB | — | — | Must | — |
LF | — | — | Must | — |
MSB | — | — | Must | — |
MSBA | — | — | Must | — |
GMSB | — | — | Must | — |
MDL | — | — | Must | — |
DL | — | — | Must | — |
BKV | — | — | Must | — |
UENB | — | — | Must | — |
KUNDE-SELBST-NN | — | — | Must | — |
MGV | — | — | Must | — |
EIV | — | — | Must | — |
RB | — | — | Must | — |
KUNDE | — | — | Must | — |
INTERESSENT | — | — | Must | — |
KN | — | — | Must | — |
UBA | — | — | Must | — |
BIKO | — | — | Must | — |
ESA | — | — | Must | — |
| rollencodenummer 01480 | Specifies the code value of the market role. | string | Must | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 01490 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| messstellenbetreiberEigenschaft 01500 | MSB property | Enum MSBEigenschaft | X | — |
GRUNDZUSTAENDIGER_MESSSTELLENBETREIBER | — | — | X | — |
WETTBEWERBLICHER_MESSSTELLENBETREIBER | — | — | X | — |
AUFFANGMESSSTELLENBETREIBER | — | — | X | — |
| rollencodenummer 01510 | Specifies the code value of the market role. | string | X | — |
| zugeordneteDefinition | — | object | May | — |
| leistungskurvendefinition 01520 | leistungskurvendefinition | string | Must | — |
| schaltzeitdefinition 01530 | schaltzeitdefinition | string | Must | — |
| TECHNISCHE_RESSOURCE [ ] | — | object[] | May | — |
| art 01540 | Technical resource type | Enum TechnischeRessourceArt | Must | — |
STROMERZEUGUNG | — | — | Must | — |
STROMVERBRAUCH | — | — | Must | — |
SPEICHER | — | — | Must | — |
| artEMobilitaet 01550 | ArtEmobilitaet | Enum ArtEmobilitaet | Must | — |
WB | — | — | Must | — |
LS | — | — | Must | — |
LP | — | — | Must | — |
| enwg 01560 | enwg | boolean | Must | — |
| erzeugungsart 01570 | Type of energy generation. Details generation type Example: CAV+ZF5' Generation type: ZF5: solar ZF6: wind ZG0: gas ZG1: water ZG5: other generation type | Enum Erzeugungsart | Must | — |
EEG | — | — | Must | — |
KWK | — | — | Must | — |
EEG_DV | — | — | Must | — |
KWK_DV | — | — | Must | — |
WIND | — | — | Must | — |
SOLAR | — | — | Must | — |
KERNKRAFT | — | — | Must | — |
WASSER | — | — | Must | — |
GEOTHERMIE | — | — | Must | — |
BIOMASSE | — | — | Must | — |
KOHLE | — | — | Must | — |
GAS | — | — | Must | — |
SONSTIGE | — | — | Must | — |
SONSTIGE_EEG | — | — | Must | — |
SONSTIGE_ERZEUGUNGSART | — | — | Must | — |
| referenzNetzlokation 01580 | referenzNetzlokation | string | X | — |
| referenzSteuerbareRessource 01590 | referenzSteuerbareRessource | string | X | — |
| referenzTranche 01600 | referenzTranche | string | X | — |
| ressourcenId 01610 | ressourcenId | string | X | — |
| speicherart 01620 | Type of storage. Details storage type Example: CAV+ZF7' Storage type: ZF7: hydrogen storage ZF8: pumped storage ZF9: battery storage ZG6: other storage type | Enum Speicherart | Must | — |
WASSERSTOFFSPEICHER | — | — | Must | — |
PUMPSPEICHER | — | — | Must | — |
BATTERIESPEICHER | — | — | Must | — |
SONSTIGE_SPEICHERART | — | — | Must | — |
| speicherkapazitaet 01630 | Storage capacity Example: QTY+Z42:100:KWH' | number (float) | X | — |
| verbrauchsart 01640 | Consumption type of the technical resource Example: CAV+Z64' Z64: Power/light Z65: Heat ZE5: E-mobility ZA8: Street lighting | array | Must | — |
| waermenutzung 01650 | Heat usage Example: CAV+Z56' Z56: Storage heating Z57: Heat pump Z61: Direct heating | Enum Waermenutzung | Must | — |
SPEICHERHEIZUNG | — | — | Must | — |
WAERMEPUMPE | — | — | Must | — |
DIREKTHEIZUNG | — | — | Must | — |
WAERMEPUMPE_WAERME_KAELTE | — | — | Must | — |
WAERMEPUMPE_KAELTE | — | — | Must | — |
WAERMEPUMPE_WAERME | — | — | Must | — |
| nennleistung | — | object | May | — |
| abgabe 01660 | Submission of the rated capacity | number (float) | X | — |
| aufnahme 01670 | Recording of the rated power | number (float) | X | — |
| TRANCHE [ ] | — | object[] | May | — |
| bildungTranchengroesse 01680 | BildungTranchengroesse | Enum BildungTranchengroesse | X | — |
PROZENTUAL | — | — | X | — |
AUFTEILUNGSFAKTOR | — | — | X | — |
AUFTEILUNG_TECHNISCHE_RESSOURCEN | — | — | X | — |
BERECHNUNGSFORMEL | — | — | X | — |
| referenzMarktlokationsId 01690 | referenzMarktlokationsId | string | X | — |
| tranchenId 01700 | tranchenId | string | X | — |
| aufteilungsmenge | — | object | May | — |
| einheit 01710 | Unit: measurands that can be determined by measurement or by specification | Enum Mengeneinheit | X | — |
W | — | — | X | — |
WH | — | — | X | — |
KW | — | — | X | — |
KWH | — | — | X | — |
KVARH | — | — | X | — |
MW | — | — | X | — |
MWH | — | — | X | — |
STUECK | — | — | X | — |
KUBIKMETER | — | — | X | — |
STUNDE | — | — | X | — |
TAG | — | — | X | — |
MONAT | — | — | X | — |
JAHR | — | — | X | — |
PROZENT | — | — | X | — |
ANZAHL | — | — | X | — |
VAR | — | — | X | — |
KVAR | — | — | X | — |
VARH | — | — | X | — |
KWHK | — | — | X | — |
Z16 | — | — | X | — |
KWT | — | — | X | — |
WATT_PRO_QUADRATMETER | — | — | X | — |
METER_PRO_SEKUNDE | — | — | X | — |
| wert 01720 | Value | number (float) | X | — |
| marktrollen [ ] | — | object[] | May | — |
| marktrolle 01730 | Indicates the designation of the market role in free text. | Enum Marktrolle | X | — |
NB | — | — | X | — |
LF | — | — | X | — |
MSB | — | — | X | — |
MSBA | — | — | X | — |
GMSB | — | — | X | — |
MDL | — | — | X | — |
DL | — | — | X | — |
BKV | — | — | X | — |
UENB | — | — | X | — |
KUNDE-SELBST-NN | — | — | X | — |
MGV | — | — | X | — |
EIV | — | — | X | — |
RB | — | — | X | — |
KUNDE | — | — | X | — |
INTERESSENT | — | — | X | — |
KN | — | — | X | — |
UBA | — | — | X | — |
BIKO | — | — | X | — |
ESA | — | — | X | — |
| rollencodenummer 01740 | Specifies the code value of the market role. | string | X | — |
| zaehlwerke [ ] | — | object[] | May | — |
| messprodukt 01750 | messprodukt | string | X | — |
| verwendungszweckLF 01760 | Codes according to the code list of the purposes of use Purpose of use LF | string | X | — |
| verwendungszweckNB 01770 | Codes according to the code list of the purposes of use Purpose of use NB | string | X | — |
| verwendungszweckUENB 01780 | Codes according to the code list of the purposes of use Purpose of use ÜNB | string | X | — |
| ZAEHLER [ ] | — | object[] | May | — |
| befestigungsart 01790 | Mounting type | Enum Befestigungsart | Must | — |
STECKTECHNIK | — | — | Must | — |
DREIPUNKT | — | — | Must | — |
HUTSCHIENE | — | — | Must | — |
EINSTUTZEN | — | — | Must | — |
ZWEISTUTZEN | — | — | Must | — |
| fernschaltung 01800 | Remote switching | Enum Fernschaltung | X | — |
VORHANDEN | — | — | X | — |
NICHT_VORHANDEN | — | — | X | — |
| gateway 01810 | Specification of a SMGW with which the meter is parameterised | string | X | — |
| marktlokationsId 01820 | marktlokationsId | string | X | — |
| messlokationsId 01830 | messlokationsId | string | X | — |
| messwerterfassung 01840 | Meter reading capture at the metering point | Enum Messwerterfassung | Must | — |
FERNAUSLESBAR | — | — | Must | — |
MANUELL_AUSGELESENE | — | — | Must | — |
| tarifart 01850 | Specification regarding supported tariff types. | Enum Tarifart | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
SMART_METER | — | — | Must | — |
LEISTUNGSGEMESSEN | — | — | Must | — |
| zaehlerauspraegung 01860 | Specification regarding the direction of the meter. | Enum Zaehlerauspraegung | Must | — |
EINRICHTUNGSZAEHLER | — | — | Must | — |
ZWEIRICHTUNGSZAEHLER | — | — | Must | — |
| zaehlernummer 01870 | Numbering of the meter, assigned by the metering point operator | string | X | — |
| zaehlertyp 01880 | Typing of the meter | Enum Zaehlertyp | Must | — |
DREHSTROMZAEHLER | — | — | Must | — |
BALGENGASZAEHLER | — | — | Must | — |
DREHKOLBENZAEHLER | — | — | Must | — |
SMARTMETER | — | — | Must | — |
LEISTUNGSZAEHLER | — | — | Must | — |
MAXIMUMZAEHLER | — | — | Must | — |
TURBINENRADGASZAEHLER | — | — | Must | — |
ULTRASCHALLGASZAEHLER | — | — | Must | — |
WECHSELSTROMZAEHLER | — | — | Must | — |
WIRBELGASZAEHLER | — | — | Must | — |
MESSDATENREGISTRIERGERAET | — | — | Must | — |
ELEKTRONISCHERHAUSHALTSZAEHLER | — | — | Must | — |
SONDERAUSSTATTUNG | — | — | Must | — |
WASSERZAEHLER | — | — | Must | — |
MODERNEMESSEINRICHTUNG | — | — | Must | — |
| zaehlertypspezifikation 01890 | Typing of the meter (specification for EHZ and MME) | Enum ZaehlertypSpezifikation | Must | — |
EDL40 | — | — | Must | — |
EDL21 | — | — | Must | — |
SONSTIGER_EHZ | — | — | Must | — |
MME_STANDARD | — | — | Must | — |
MME_MEDA | — | — | Must | — |
| geraete [ ] | — | object[] | May | — |
| geraetenummer 01900 | The number printed on the device, which is assigned by the MSB. | string | X | — |
| geraetetyp 01910 | List of possible billable device types | Enum Geraetetyp | X | — |
WECHSELSTROMZAEHLER | — | — | X | — |
DREHSTROMZAEHLER | — | — | X | — |
ZWEIRICHTUNGSZAEHLER | — | — | X | — |
RLM_ZAEHLER | — | — | X | — |
IMS_ZAEHLER | — | — | X | — |
BALGENGASZAEHLER | — | — | X | — |
MAXIMUMZAEHLER | — | — | X | — |
MULTIPLEXANLAGE | — | — | X | — |
PAUSCHALANLAGE | — | — | X | — |
VERSTAERKERANLAGE | — | — | X | — |
SUMMATIONSGERAET | — | — | X | — |
IMPULSGEBER | — | — | X | — |
EDL_21_ZAEHLERAUFSATZ | — | — | X | — |
VIER_QUADRANTEN_LASTGANGZAEHLER | — | — | X | — |
MENGENUMWERTER | — | — | X | — |
STROMWANDLER | — | — | X | — |
SPANNUNGSWANDLER | — | — | X | — |
DATENLOGGER | — | — | X | — |
KOMMUNIKATIONSANSCHLUSS | — | — | X | — |
MODEM | — | — | X | — |
TELEKOMMUNIKATIONSEINRICHTUNG | — | — | X | — |
KOMMUNIKATIONSEINRICHTUNG | — | — | X | — |
DREHKOLBENGASZAEHLER | — | — | X | — |
TURBINENRADGASZAEHLER | — | — | X | — |
ULTRASCHALLZAEHLER | — | — | X | — |
WIRBELGASZAEHLER | — | — | X | — |
MODERNE_MESSEINRICHTUNG | — | — | X | — |
ELEKTRONISCHER_HAUSHALTSZAEHLER | — | — | X | — |
STEUEREINRICHTUNG | — | — | X | — |
TECHNISCHESTEUEREINRICHTUNG | — | — | X | — |
TARIFSCHALTGERAET | — | — | X | — |
RUNDSTEUEREMPFAENGER | — | — | X | — |
OPTIONALE_ZUS_ZAEHLEINRICHTUNG | — | — | X | — |
MESSWANDLERSATZ_IMS_MME | — | — | X | — |
KOMBIMESSWANDLER_IMS_MME | — | — | X | — |
TARIFSCHALTGERAET_IMS_MME | — | — | X | — |
RUNDSTEUEREMPFAENGER_IMS_MME | — | — | X | — |
TEMPERATUR_KOMPENSATION | — | — | X | — |
HOECHSTBELASTUNGS_ANZEIGER | — | — | X | — |
SONSTIGES_GERAET | — | — | X | — |
SMARTMETERGATEWAY | — | — | X | — |
STEUERBOX | — | — | X | — |
BLOCKSTROMWANDLER | — | — | X | — |
KOMBIMESSWANDLER | — | — | X | — |
MODEM_GSM | — | — | X | — |
ETHERNET_KOM | — | — | X | — |
PLC_COM | — | — | X | — |
MODEM_FESTNETZ | — | — | X | — |
DSL_KOM | — | — | X | — |
LTE_KOM | — | — | X | — |
DICHTEMENGENUMWERTER | — | — | X | — |
TEMPERATURMENGENUMWERTER | — | — | X | — |
ZUSTANDSMENGENUMWERTER | — | — | X | — |
MESSDATENREGISTRIERGERAET | — | — | X | — |
WANDLER | — | — | X | — |
BEFESTIGUNGSEINRICHTUNG | — | — | X | — |
| weitereGeraetenummern 01920 | weitereGeraetenummern | array | X | — |
| geraeteeigenschaften | — | object | May | — |
| faktor 01930 | faktor | number (float) | Must | — |
| geraetemerkmal 01940 | Geraetemerkmal | Enum Geraetemerkmal | Must | — |
EINTARIF | — | — | Must | — |
ZWEITARIF | — | — | Must | — |
MEHRTARIF | — | — | Must | — |
GAS_G2P5 | — | — | Must | — |
GAS_G4 | — | — | Must | — |
GAS_G6 | — | — | Must | — |
GAS_G10 | — | — | Must | — |
GAS_G16 | — | — | Must | — |
GAS_G25 | — | — | Must | — |
GAS_G40 | — | — | Must | — |
GAS_G65 | — | — | Must | — |
GAS_G100 | — | — | Must | — |
GAS_G160 | — | — | Must | — |
GAS_G250 | — | — | Must | — |
GAS_G350 | — | — | Must | — |
GAS_G400 | — | — | Must | — |
GAS_G4000 | — | — | Must | — |
GAS_G650 | — | — | Must | — |
GAS_G6500 | — | — | Must | — |
GAS_G1000 | — | — | Must | — |
GAS_G10000 | — | — | Must | — |
GAS_G12500 | — | — | Must | — |
GAS_G1600 | — | — | Must | — |
GAS_G16000 | — | — | Must | — |
GAS_G2500 | — | — | Must | — |
IMPULSGEBER_G4_G100 | — | — | Must | — |
IMPULSGEBER_G100 | — | — | Must | — |
MODEM_GSM | — | — | Must | — |
MODEM_GPRS | — | — | Must | — |
MODEM_FUNK | — | — | Must | — |
MODEM_GSM_O_LG | — | — | Must | — |
MODEM_GSM_M_LG | — | — | Must | — |
MODEM_FESTNETZ | — | — | Must | — |
MODEM_GPRS_M_LG | — | — | Must | — |
PLC_COM | — | — | Must | — |
ETHERNET_KOM | — | — | Must | — |
DSL_KOM | — | — | Must | — |
LTE_KOM | — | — | Must | — |
RUNDSTEUEREMPFAENGER | — | — | Must | — |
TARIFSCHALTGERAET | — | — | Must | — |
ZUSTANDS_MU | — | — | Must | — |
TEMPERATUR_MU | — | — | Must | — |
KOMPAKT_MU | — | — | Must | — |
SYSTEM_MU | — | — | Must | — |
UNBESTIMMT | — | — | Must | — |
WASSER_MWZW | — | — | Must | — |
WASSER_WZWW | — | — | Must | — |
WASSER_WZ01 | — | — | Must | — |
WASSER_WZ02 | — | — | Must | — |
WASSER_WZ03 | — | — | Must | — |
WASSER_WZ04 | — | — | Must | — |
WASSER_WZ05 | — | — | Must | — |
WASSER_WZ06 | — | — | Must | — |
WASSER_WZ07 | — | — | Must | — |
WASSER_WZ08 | — | — | Must | — |
WASSER_WZ09 | — | — | Must | — |
WASSER_WZ10 | — | — | Must | — |
WASSER_VWZ04 | — | — | Must | — |
WASSER_VWZ05 | — | — | Must | — |
WASSER_VWZ06 | — | — | Must | — |
WASSER_VWZ07 | — | — | Must | — |
WASSER_VWZ10 | — | — | Must | — |
DICHTEMENGENUMWERTER | — | — | Must | — |
TEMPERATURMENGENUMWERTER | — | — | Must | — |
ZUSTANDSMENGENUMWERTER | — | — | Must | — |
BLOCKSTROMWANDLER | — | — | Must | — |
MESSWANDLERSATZ_IMS_MME | — | — | Must | — |
KOMBIMESSWANDLER | — | — | Must | — |
SPANNUNGSWANDLER | — | — | Must | — |
| zaehlwerke [ ] | — | object[] | May | — |
| bezeichnung 01950 | Additional designation, e.g. Zählwerk_Wirkarbeit. | string | Must | — |
| konfiguration 01960 | Configuration (iMSys) of the meter register | string | X | — |
| nachkommastelle 01970 | nachkommastelle | integer | Must | — |
| obisKennzahl 01980 | The OBIS code for the register, which defines which measured quantity is reported with the reading. Only register readings with this OBIS code are recorded at this register. Example:1-0:1.8.1 for electrical active energy. | string | X | — |
| vorkommastelle 01990 | vorkommastelle | integer | Must | — |
| wertegranularitaet 02000 | Value granularity | Enum Wertegranularitaet | Must | — |
JAEHRLICH | — | — | Must | — |
HALBJAEHRLICH | — | — | Must | — |
QUARTALSWEISE | — | — | Must | — |
MONATLICH | — | — | Must | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer * 02010 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| antwortstatus * 02020 | Response status / STS+E01 | string | X | — |
| antwortstatusCodeliste * 02030 | Response status code list / STS+E01 | string | X | — |
| datumleistungsbeginn * 02040 | Date of the planned start of service / DTM+76 | string (date-time) | X | — |
| dokumentennummer * 02050 | EDIFACT reference from the BGM segment / BGM | string | X | — |
| kategorie * 02060 | Qualifier from the beginning of the EDIFACT message / BGM | string | X | — |
| nachrichtendatum * 02070 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 02080 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 02090 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 02100 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vorgangsnummer * 02110 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 02120 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 02130 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 02140 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 02150 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55169 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0100070 | Registrations | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/ message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00160 | Message recipient | — | X | — |
303900170 | MP-ID | — | X | — |
3055 900180 | GS1 | — | X | — |
3055 29300190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400200 | Transaction | — | X | — |
740200210 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 7600220 | Delivery date/time, scheduled | — | X | — |
238000230 | Date or time or time span, value | — | X | [UB1] |
2379 30300240 | CCYYMMDDHHMMZZZ | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700250 | Transaction reason | — | X | — |
9013 E0100260 | Move-in/move-out (relocation) | — | X | — |
9013 E0200270 | Move-in to creation | — | X | — |
9013 E0300280 | Change | — | X | — |
| SG4.STS | — | — | Must | [249] |
9015 E0100290 | Status of the response | — | X | — |
901300300 | Code of the check step | — | X | — |
1131 S_006300310 | Electricity code list no. S_0063 | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1800320 | Grid location | — | X | — |
322500330 | ID of the grid location | — | X | [960] |
| SG5.LOC | — | — | Must | — |
3227 Z1600340 | Market location | — | X | — |
322500350 | ID of the market location | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z2000360 | Technical resource | — | X | — |
322500370 | ID of the technical resource | — | X | [922] |
| SG5.LOC | — | — | Must | — |
3227 Z1900380 | Controllable resource | — | X | — |
322500390 | ID of the controllable resource | — | X | [961] |
| SG5.LOC | — | — | Must | — |
3227 Z2100400 | Tranche | — | X | — |
322500410 | ID of the tranche | — | X | [950] |
| SG5.LOC | — | — | Must | — |
3227 Z1700420 | Metering location | — | X | — |
322500430 | ID of the metering location | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300440 | Check identifier | — | X | — |
1154 5516900450 | WiM electricity / confirmation of commitment request | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00460 | Transaction reference number | — | X | — |
115400470 | Transaction number | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 Z5000480 | Scheduling data of the market location | — | X | — |
115400490 | ID of the market location / reference to time period ID | — | X | [950] |
| SG6.DTM | — | — | Must | [234] |
2005 75200500 | Periodic meter reading | — | X | — |
238000510 | Date or time or time span, value | — | X | — |
2379 10400520 | MMWW-MMWW | — | X | — |
2379 10600530 | MMDD | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z7800540 | Reference to the location bundle structure | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3100550 | Location bundle structure | — | X | — |
1153 Z3900560 | No standardized location bundle structure available | — | X | — |
115400570 | ID of the location bundle structure | — | X | [333] |
115600580 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.SEQ | — | — | Must | — |
1229 Z5800590 | Assignment of the location to the object code of the location bundle | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200600 | Grid location | — | X | — |
1153 Z1800610 | Market location | — | X | — |
1153 Z1900620 | Metering location | — | X | — |
1153 Z3700630 | Technical resource | — | X | — |
115400640 | ID of a location | — | X | ([451] ∧ [950]) ⊻ ([452] ∧ [951]) ⊻ ([450] ∧ [960]) ⊻ ([456] ∧ [922]) |
| SG8.RFF | — | — | Must | [2312] |
1153 Z3300650 | Object code of the location in the location bundle structure | — | X | — |
115400660 | Object code | — | X | — |
115600670 | Consecutive number of a location bundle within the business transaction | — | — | M [914] ∧ [937] [32] |
| SG8.RFF | — | — | Must | ([176] ∧ (([173] ∧ [179]) ⊻ ([174] ∧ [175]))) ⊻ ([177] ∧ [178] ∧ [179]) |
1153 Z3400680 | upstream metering location | — | X | — |
1153 Z3500690 | upstream grid location | — | X | — |
115400700 | ID of a location | — | X | ([442] ∧ [951]) ⊻ ([440] ∧ [960]) |
| SG8.RFF | — | — | Must | [179] ∧ [291] |
1153 Z1600710 | assigned market location | — | X | — |
115400720 | ID of the market location | — | X | [950] |
| SG8.SEQ | — | — | Must | — |
1229 Z5100730 | Data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200740 | Grid location | — | X | — |
115400750 | ID of the grid location | — | X | [960] |
| SG10.CCI | — | — | Must | — |
7059 Z4900760 | Control channel | — | X | — |
7037 ZF200770 | No control channel available | — | X | — |
7037 ZF300780 | Control channel present | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB300790 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9100800 | MSB | — | X | — |
113100810 | MP-ID | — | X | — |
7110 Z3900820 | Default metering point operator | — | X | — |
7110 Z4000830 | Competitive metering point operator | — | X | — |
7110 Z4100840 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z5700850 | OBIS data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200860 | Grid location | — | X | — |
115400870 | ID of the grid location | — | X | [960] |
| SG8.PIA | — | — | Must | [159] |
4347 500880 | Product identification | — | X | — |
714000890 | OBIS code of the grid location | — | X | — |
7143 SRW00900 | OBIS code | — | X | — |
714300910 | Purpose of use NB | — | X | [353] |
1131 Z1600920 | EDI@Energy code list of purposes of use | — | X | — |
714300930 | Purpose of use LF | — | X | [354] |
1131 Z1600940 | EDI@Energy code list of purposes of use | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1100950 | Product | — | X | — |
7037 ZF600960 | No product assigned | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z6000970 | Product data of the grid location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3200980 | Grid location | — | X | — |
115400990 | ID of a grid location | — | X | [960] |
| SG8.PIA | — | — | Must | — |
4347 501000 | Product identification | — | X | — |
714001010 | Configuration product code | — | X | [412] |
7143 Z1201020 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5301030 | Code of the power curve definition | — | X | — |
703701040 | Code of the power curve definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB301050 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8801060 | NB | — | X | — |
7111 Z8901070 | LF | — | X | — |
113101080 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA701090 | LF | — | X | [1P0..1] |
7037 ZA801100 | NB | — | X | [1P0..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z0101110 | Data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801120 | Market location | — | X | — |
115401130 | ID of the market location | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 26501140 | Estimated annual quantity total/ annual consumption forecast for specific energy for day-parameter-dependent market location | — | X | — |
6063 Z0801150 | Adjusted electrical energy in accordance with Annex D of the VDN guideline "Load profiles for interruptible consumption devices" | — | X | — |
606001160 | Quantity | — | X | [902] |
6411 Z1601170 | kWh/K (kilowatt hour/Kelvin) | — | X | [103] |
6411 KWH01180 | Kilowatt hour | — | X | [104] |
| SG9.QTY | — | — | Must | — |
6063 3101190 | Estimated annual quantity total | — | X | — |
606001200 | Quantity specification | — | X | [902] ∧ [937] |
6411 KWH01210 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3001220 | Delivery direction | — | X | — |
7037 Z0601230 | Generation | — | X | — |
7037 Z0701240 | Consumption | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB301250 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | [78] ∧ [221] |
7111 Z8901260 | LF | — | X | — |
113101270 | MP-ID | — | X | [611] |
| SG10.CAV | — | — | Must | — |
7111 Z9001280 | ÜNB | — | X | — |
113101290 | MP-ID | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9101300 | MSB | — | X | — |
113101310 | MP-ID | — | X | [621] |
7110 Z3901320 | Default metering point operator | — | X | — |
7110 Z4001330 | Competitive metering point operator | — | X | — |
7110 Z4101340 | Fallback metering point operator | — | X | — |
7110 Z1901350 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2001360 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0301370 | Voltage level of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0301380 | Extra-high voltage | — | X | — |
7111 E0401390 | High voltage | — | X | — |
7111 E0501400 | Medium voltage | — | X | — |
7111 E0601410 | Low voltage | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z8301420 | Metering classification of the market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z5201430 | iMS | — | X | — |
7111 Z5301440 | kME / mME | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 601450 | Responsible party | — | X | — |
7037 ZA801460 | NB | — | X | — |
7037 ZA901470 | ÜNB | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZC001480 | Forecast based on values | — | X | — |
7037 ZA601490 | Forecast based on profiles | — | X | — |
| SG10.CAV | — | — | Must | [210] ∧ ([2182] ⊻ ([90] ∧ [2183])) |
7111 E0201500 | SLP/SEP | — | X | [1P0..1] |
7111 E1401510 | TLP/TEP | — | X | [1P0..1] |
7111 Z3601520 | TEP with reference measurement | — | X | [1P0..1] |
| SG10.CCI | — | — | Must | — |
7037 Z3401530 | Type of the generating market location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3301540 | EEG market location without DV obligation | — | X | — |
7111 Z3401550 | KWKG market location without DV obligation | — | X | — |
7111 Z3501560 | other market location | — | X | — |
7111 Z3701570 | EEG market location with DV obligation | — | X | — |
7111 Z4601580 | KWKG market location with DV obligation | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 ZA201590 | Processing model | — | X | — |
7037 ZE901600 | Model 1 "Balancing at the market location" | — | X | — |
7037 ZF001610 | Model 2 "Balancing in the balancing area (BG) of the LPB" | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2701620 | Required metering product of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801630 | Market location | — | X | — |
115401640 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 501650 | Product identification | — | X | — |
714001660 | Metering product code | — | X | [425] |
7143 Z1101670 | Product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3901680 | Code of the metering time period definition | — | X | — |
7059 Z4101690 | No metering time period required for metering product | — | X | [417] |
703701700 | Code of the metering time period definition | — | X | [438] |
| SG10.CCI | — | — | Must | — |
7037 ZA801710 | NB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8401720 | Grid usage settlement | — | X | [19P1..1] ⊻ [20P1..1] ⊻ [22P1..1] ⊻ [26P1..1] |
7111 Z8501730 | Balancing group settlemen t | — | X | [21P0..1] ⊻ [22P0..1] ⊻ [23P0..1] ⊻ [24P0..1] |
7111 Z8601740 | Excess/shortfall quantity settlement | — | X | [20P1..1] ⊻ [27P1..1] |
7111 Z9201750 | Transmission to the HKNR | — | X | [23P1..1] ⊻ [24P1..1] |
7111 ZE101760 | There is no purpose of use | — | X | [38P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA701770 | LF | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8401780 | Grid usage settlement | — | X | [19P0..1] ⊻ [20P0..1] ⊻ [22P0..1] ⊻ [26P0..1] |
7111 Z8501790 | Balancing group settlemen t | — | X | [21P1..1] ⊻ [22P1..1] ⊻ [23P1..1] ⊻ [24P1..1] |
7111 Z8601800 | Excess/shortfall quantity settlement | — | X | [20P1..1] ⊻ [27P1..1] |
7111 Z4701810 | End customer billing | — | X | [19P1..1] ⊻ [20P0..1] ⊻ [22P1..1] ⊻ [24P1..1] ⊻ [25P1..1] ⊻ [26P0..1] ⊻ [27P1..1] |
7111 ZE101820 | There is no purpose of use | — | X | [38P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA901830 | ÜNB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8501840 | Balancing group settlemen t | — | X | [1P0..1] |
7111 ZB501850 | For the determination of the balance of balancing groups | — | X | [1P1..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z0201860 | OBIS data of the market location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1801870 | Market location | — | X | — |
115401880 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 501890 | Product identification | — | X | — |
714001900 | OBIS code of the market location | — | X | [314] |
7143 SRW01910 | OBIS code | — | X | — |
714301920 | Purpose of use NB | — | X | [381] |
1131 Z1601930 | EDI@Energy code list of purposes of use | — | X | — |
714301940 | Purpose of use LF | — | X | [382] |
1131 Z1601950 | EDI@Energy code list of purposes of use | — | X | — |
714301960 | Purpose of use ÜNB | — | X | [383] |
1131 Z1601970 | EDI@Energy code list of purposes of use | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE401980 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD901990 | Annually | — | X | — |
7111 ZE802000 | Semi-annual | — | X | — |
7111 ZE902010 | Quarterly | — | X | — |
7111 ZB702020 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3902030 | Code of the metering time period definition | — | X | — |
703702040 | Code of the metering time period definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3802050 | Code of the metering time period register | — | X | — |
703702060 | Code of the metering time period register | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1502070 | Data of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2002080 | Tranche | — | X | — |
115402090 | ID of the tranche | — | X | [950] |
| SG8.RFF | — | — | Must | — |
1153 Z1602100 | assigned market location | — | X | — |
115402110 | ID of the market location | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 1102120 | Distribution quantity | — | X | — |
606002130 | Quantity specification in % | — | X | [914] ∧ [930] ∧ [955] |
6411 P102140 | Percent | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB302150 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8902160 | LF | — | X | — |
113102170 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3702180 | Basis for determining the tranche size | — | X | — |
7037 ZD102190 | Percentage-based | — | X | — |
7037 ZD202200 | Distribution factor based on reference carrier/ installed capacity | — | X | — |
7037 ZH102210 | Distribution across technical resources | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1602220 | Required product of the tranche | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z2002230 | Tranche | — | X | — |
115402240 | ID of a tranche | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 502250 | Product identification | — | X | — |
714002260 | Metering product code | — | X | [426] |
7143 Z1102270 | Product | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA802280 | NB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8502290 | Balancing group settlemen t | — | X | [1P0..1] |
7111 Z9202300 | Transmission to the HKNR | — | X | [1P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA702310 | LF | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8502320 | Balancing group settlemen t | — | X | [1P1..1] |
7111 Z4702330 | End customer billing | — | X | [1P1..1] |
| SG10.CCI | — | — | Must | — |
7037 ZA902340 | ÜNB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8502350 | Balancing group settlemen t | — | X | [1P0..1] |
7111 ZB502360 | For the determination of the balance of balancing groups | — | X | [1P1..1] |
| SG10.CAV | — | — | Must | [446] |
| SG8.SEQ | — | — | Must | — |
1229 Z5202370 | Data of the technical resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3702380 | Technical resource | — | X | — |
115402390 | ID of the technical resource | — | X | [922] |
| SG8.RFF | — | — | Should | [166] ∧ [699] |
1153 Z3802400 | Controllable resource | — | X | — |
115402410 | ID of the controllable resource | — | X | [961] |
| SG8.RFF | — | — | Should | [166] ∧ [700] |
1153 Z3202420 | Grid location | — | X | — |
115402430 | ID of the grid location | — | X | [960] |
| SG8.RFF | — | — | Should | [166] ∧ [447] ∧ [701] |
1153 Z2002440 | Tranche | — | X | — |
115402450 | ID of the tranche | — | X | [950] |
| SG9.QTY | — | — | Must | — |
6063 Z4302460 | Rated power (input) | — | X | — |
606002470 | Quantity | — | X | — |
6411 KWT02480 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4402490 | Rated power (output) | — | X | — |
606002500 | Quantity | — | X | — |
6411 KWT02510 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4202520 | Storage capacity | — | X | — |
606002530 | Quantity | — | X | — |
6411 KWH02540 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1702550 | Type of electricity consumption | — | X | — |
7059 Z5002560 | Type of electricity generation | — | X | — |
7059 Z5602570 | Storage | — | X | — |
| SG10.CAV | — | — | Must | [446] |
7111 Z6402580 | Power/light | — | X | [1P0..1] |
7111 Z6502590 | Heat/cold | — | X | [1P0..1] |
7111 ZE502600 | E-mobility | — | X | [1P0..1] |
7111 ZA802610 | Street lighting | — | X | [1P0..1] |
| SG10.CAV | — | — | Must | [239] |
7111 Z5602620 | Storage heating | — | X | — |
7111 Z5702630 | Heat pump (unspecified) | — | X | — |
7111 Z6102640 | Direct heating | — | X | — |
7111 ZV502650 | Heat pump (heat and cold) | — | X | — |
7111 ZV602660 | Heat pump (cold) | — | X | — |
7111 ZV702670 | Heat pump (heat) | — | X | — |
| SG10.CAV | — | — | Must | [95] |
7111 ZE602680 | Wallbox | — | X | — |
7111 Z8702690 | E-mobility charging station | — | X | — |
7111 ZE702700 | Charging park | — | X | — |
| SG10.CAV | — | — | Must | [447] |
7111 ZF502710 | Solar | — | X | — |
7111 ZF602720 | Wind | — | X | — |
7111 ZG002730 | Gas | — | X | — |
7111 ZG102740 | Water | — | X | — |
7111 ZG502750 | Other generation type | — | X | — |
| SG10.CAV | — | — | Must | [448] |
7111 ZF702760 | Hydrogen storage | — | X | — |
7111 ZF802770 | Pumped storage | — | X | — |
7111 ZF902780 | Battery storage | — | X | — |
7111 ZG602790 | Other storage type | — | X | — |
| SG10.CAV | — | — | Must | [446] ⊻ [448] |
7111 ZG802800 | Technical resource is covered by § 14a EnWG | — | X | — |
7111 ZG902810 | Technical resource is not covered by § 14a EnWG | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z6202820 | Data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3802830 | Controllable resource | — | X | — |
115402840 | ID of the controllable resource | — | X | [961] |
| SG10.CCI | — | — | Must | — |
7059 Z4902850 | Control channel | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF202860 | Service description of the control channel | — | X | — |
1131 Z1402870 | On/Off | — | X | — |
1131 Z1502880 | Tiered | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB302890 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9102900 | MSB | — | X | — |
113102910 | MP-ID | — | X | — |
7110 Z3902920 | Default metering point operator | — | X | — |
7110 Z4002930 | Competitive metering point operator | — | X | — |
7110 Z4102940 | Fallback metering point operator | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z6102950 | Product data of the controllable resource | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z3802960 | Controllable resource | — | X | — |
115402970 | ID of a controllable resource | — | X | [961] |
| SG8.PIA | — | — | Must | [81] |
4347 502980 | Product identification | — | X | — |
714002990 | Configuration product code | — | X | — |
7143 Z1203000 | Configuration product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1103010 | Product | — | X | — |
7037 ZF603020 | No product assigned | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z5203030 | Code of the switching time definition | — | X | — |
7059 Z5303040 | Code of the power curve definition | — | X | — |
703703050 | Code of the definition | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZB303060 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8803070 | NB | — | X | — |
7111 Z8903080 | LF | — | X | — |
113103090 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZA803100 | NB | — | X | [1P0..1] |
7037 ZA703110 | LF | — | X | [1P0..1] |
| SG8.SEQ | — | — | Must | — |
1229 Z1803120 | Data of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1903130 | Metering location | — | X | — |
115403140 | ID of the metering location | — | X | [951] |
| SG10.CCI | — | — | Must | — |
7037 ZB303150 | Assigned market partner | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z9103160 | MSB | — | X | — |
113103170 | MP-ID | — | X | [622] |
7110 Z3903180 | Default metering point operator | — | X | — |
7110 Z4003190 | Competitive metering point operator | — | X | — |
7110 Z4103200 | Fallback metering point operator | — | X | — |
7110 Z1903210 | On a contractual basis towards the connection user / connection holder | — | X | — |
7110 Z2003220 | In the exercise of the continued commitment by the gMSB | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZF003230 | gMSB | — | X | — |
113103240 | MP-ID | — | X | — |
| SG10.CAV | — | — | Must | [184] |
7111 ZB403250 | MSBA | — | X | — |
113103260 | MP-ID | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E0403270 | Voltage level of the metering location | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 E0303280 | Extra-high voltage | — | X | — |
7111 E0403290 | High voltage | — | X | — |
7111 E0503300 | Medium voltage | — | X | — |
7111 E0603310 | Low voltage | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z0103320 | Scope of use | — | X | — |
7037 Z8203330 | ID of the metering location handled in the process | — | X | [2236] |
7037 Z8103340 | ID of the metering location in the location bundle | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3203350 | Operating state of the metering location | — | X | — |
7037 ZC103360 | Metering location blocked and may not be unblocked | — | X | — |
7037 ZC203370 | Metering location blocked and may be unblocked | — | X | — |
7037 ZC303380 | Metering location in regular operation | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1903390 | Required product of the metering location | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1903400 | Metering location | — | X | — |
115403410 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Must | [429] |
1153 Z1803420 | Market location | — | X | — |
115403430 | ID of a market location | — | X | [950] |
| SG8.PIA | — | — | Must | — |
4347 503440 | Product identification | — | X | — |
714003450 | Metering product code | — | X | [427] |
7143 Z1103460 | Product | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3503470 | Description required value | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZC903480 | Second measurement required for comparative measurement | — | X | — |
7110 Z0603490 | present | — | X | — |
7110 Z0703500 | not present | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z8803510 | NB | — | X | — |
7110 Z0603520 | present | — | X | — |
7110 Z0703530 | not present | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z3903540 | Code of the metering time period definition | — | X | — |
7059 Z4103550 | No metering time period required for metering product | — | X | [417] |
703703560 | Code of the metering time period definition | — | X | [438] |
| SG8.SEQ | — | — | Must | — |
1229 Z0303570 | Metering device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1903580 | Metering location | — | X | — |
115403590 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Should | [166] ∧ [215] |
1153 Z1403600 | Smart meter gateway | — | X | — |
115403610 | Identification / number of the smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1303620 | Meter type | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AHZ03630 | analog household meter (three-phase current) | — | X | — |
7111 WSZ03640 | analog alternating current meter | — | X | — |
7111 LAZ03650 | Load curve meter | — | X | — |
7111 MAZ03660 | Maximum demand meter | — | X | — |
7111 MME03670 | modern metering device according to MsbG | — | X | — |
7111 EHZ03680 | electronic household meter | — | X | — |
7111 IVA03690 | Individual reconciliation (special equipment) | — | X | — |
7110 Z0103700 | EDL40 | — | X | [136] |
7110 Z0203710 | EDL21 | — | X | [136] |
7110 Z0303720 | other EHZ | — | X | [136] |
7110 Z0403730 | Standard | — | X | [346] |
7110 Z0503740 | MeDa meter | — | X | [346] |
| SG10.CAV | — | — | Must | — |
7111 Z3003750 | Device number | — | X | — |
711003760 | Device number | — | X | — |
| SG10.CAV | — | — | Must | [139] |
7111 ETZ03770 | Single tariff | — | X | — |
7111 ZTZ03780 | Two-tariff | — | X | — |
7111 NTZ03790 | Multi-tariff | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ERZ03800 | Single-direction meter | — | X | — |
7111 ZRZ03810 | Bidirectional meter | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z5803820 | Remote switching of the metering device | — | X | — |
7110 Z0603830 | present | — | X | — |
7110 Z0703840 | not present | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2803850 | Mounting type metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 BKE03860 | Plug-in technology (mounting and contacting device) | — | X | — |
7111 DPA03870 | 3- Three-point suspension | — | X | — |
7111 HUT03880 | DIN rail | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 E1203890 | Meter reading capture at the metering device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 AMR03900 | remotely readable meters | — | X | — |
7111 MMR03910 | manually read meters | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2003920 | OBIS data of the metering device | — | X | — |
| SG8.RFF | — | — | Must | [78] ∧ [665] |
1153 MG03930 | Device number of the meter | — | X | [441] |
1153 Z1403940 | Smart meter gateway | — | X | — |
115403950 | Device number | — | X | — |
| SG8.RFF | — | — | Must | [78] |
1153 Z1903960 | Metering location | — | X | — |
115403970 | ID of a metering location | — | X | [951] |
| SG8.RFF | — | — | Must | [78] ∧ [402] ∧ [420] ∧ [651] |
1153 Z1803980 | Market location | — | X | — |
115403990 | ID of a market location | — | X | [950] |
| SG8.RFF | — | — | Must | [402] ∧ [420] |
1153 AGK04000 | Application reference number | — | X | — |
115404010 | Reference, identification | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 504020 | Product identification | — | X | — |
714004030 | OBIS code of the metering device | — | X | [323] |
7143 SRW04040 | OBIS code | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 ZE404050 | Value granularity | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZD904060 | Annually | — | X | — |
7111 ZE804070 | Semi-annual | — | X | — |
7111 ZE904080 | Quarterly | — | X | — |
7111 ZB704090 | Monthly | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1104100 | Product | — | X | — |
7037 Z3304110 | Integer and decimal places of the register | — | X | — |
| SG10.CAV | — | — | Must | — |
711004120 | Digits before the decimal point | — | X | — |
711004130 | Digits after the decimal point | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z6304140 | Local identifier for control purposes | — | X | — |
703604150 | Designation of the register on the device | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0404160 | Instrument transformer data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG04170 | Device number of the meter | — | X | — |
115404180 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2504190 | Instrument transformer | — | X | — |
| SG10.CAV | — | — | Must | [2317] ⊻ [2318] |
7111 Z3004200 | Device number | — | X | — |
711004210 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 MIW04220 | Current transformer set | — | X | — |
7111 MPW04230 | Combined instrument transformer set (current and voltage) | — | X | — |
7111 MBW04240 | Block current transformer | — | X | — |
7111 MUW04250 | Voltage transformer set | — | X | — |
711004260 | Instrument transformer factor | — | X | [902] [141] |
| SG8.SEQ | — | — | Must | — |
1229 Z0504270 | Communication device data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG04280 | Device number of the meter | — | X | — |
115404290 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2604300 | Communication device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004310 | Device number | — | X | — |
711004320 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 GSM04330 | GSM/GPRS/UMTS- comm. dev. | — | X | — |
7111 ETH04340 | Ethernet comm. dev. LAN/WLAN | — | X | — |
7111 PLC04350 | PLC comm. device | — | X | — |
7111 PST04360 | Landline comm. dev. TAE | — | X | — |
7111 DSL04370 | DSL comm. dev. | — | X | — |
7111 LTE04380 | LTE comm. dev. | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0604390 | Data of the technical control device | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 MG04400 | Device number of the meter | — | X | — |
115404410 | Device number | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z2704420 | Technical control device | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004430 | Device number | — | X | — |
711004440 | Device number | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 RSU04450 | Ripple control receiver | — | X | — |
7111 TSU04460 | Tariff time switch | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z1304470 | Smart meter gateway | — | X | — |
| SG10.CCI | — | — | Must | — |
7037 Z7504480 | Smart meter gateway | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004490 | Device number | — | X | — |
711004500 | Device number | — | X | [952] |
| SG8.SEQ | — | — | Must | — |
1229 Z1404510 | Control box | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1404520 | Smart meter gateway | — | X | — |
115404530 | Identification / number of the smart meter gateway | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1804540 | Market location | — | X | — |
115404550 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7037 Z7604560 | Control box | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 Z3004570 | Device number | — | X | — |
711004580 | Device number | — | X | [952] |
| SG8.SEQ | — | — | Must | — |
1229 Z2104590 | Profile data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1804600 | Market location | — | X | — |
115404610 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7059 Z0204620 | Standard load profile | — | X | — |
7059 Z0404630 | Standard feed-in profile | — | X | — |
7037 E0104640 | synthetic method | — | X | — |
7037 Z1004650 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711104660 | Code of the standardized profile | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z0804670 | Profile set data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1804680 | Market location | — | X | — |
115404690 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7059 Z0304700 | day-parameter-dependent load profile | — | X | — |
7059 Z0504710 | day-parameter-dependent feed-in profile | — | X | — |
7037 E0104720 | synthetic method | — | X | — |
7037 Z1004730 | analytical method | — | X | — |
| SG10.CAV | — | — | Must | — |
711104740 | Code of the standardized profile | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z9904750 | Measuring station of the daily parameter (currently only the temperature is a permitted daily parameter) | — | X | — |
7059 ZA004760 | Climate zone of the daily parameter (currently is daily parameter) | — | X | — |
703704770 | ID of climate zone / temperature measuring point | — | X | — |
113104780 | Service provider | — | X | [58] |
3055 8904790 | Assigned by the trader (here grid operator) | — | X | — |
3055 29304800 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z3804810 | Reference profile data | — | X | — |
| SG8.RFF | — | — | Must | — |
1153 Z1804820 | Market location | — | X | — |
115404830 | ID of a market location | — | X | [950] |
| SG10.CCI | — | — | Must | — |
7059 Z0504840 | day-parameter-dependent feed-in profile | — | X | — |
| SG10.CAV | — | — | Must | — |
711104850 | Code of the reference profile | — | X | — |
| SG12.NAD | — | — | Must | — |
3035 Z0904860 | Customer of the LF | — | X | — |
303604870 | Name | — | X | — |
3045 Z0104880 | Structure of person names | — | X | — |
3045 Z0204890 | Structure of the company name | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1804900 | Market location | — | X | — |
115404910 | ID of the market location | — | X | [950] |
| SG12.NAD | — | — | Must | — |
3035 Z0404920 | Correspondence address of the customer of the LF | — | X | — |
303604930 | Name | — | X | — |
3045 Z0104940 | Structure of person names | — | X | — |
3045 Z0204950 | Structure of the company name | — | X | — |
304204960 | Street and house number or PO box | — | X | — |
316404970 | City | — | X | — |
325104980 | Postal code | — | — | M [268] S [166] |
320704990 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1805000 | Market location | — | X | — |
115405010 | ID of the market location | — | X | [950] |
| SG12.NAD | — | — | Must | — |
3035 Z0705020 | Customer of the MSB | — | X | — |
303605030 | Name | — | X | — |
3045 Z0105040 | Structure of person names | — | X | — |
3045 Z0205050 | Structure of the company name | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1905060 | Metering location | — | X | — |
115405070 | ID of the metering location | — | X | [951] |
| SG12.NAD | — | — | Must | — |
3035 Z0805080 | Correspondence address of the customer of the MSB | — | X | — |
303605090 | Name | — | X | — |
3045 Z0105100 | Structure of person names | — | X | — |
3045 Z0205110 | Structure of the company name | — | X | — |
304205120 | Street and house number or PO box | — | X | — |
316405130 | City | — | X | — |
325105140 | Postal code | — | — | M [268] S [166] |
320705150 | Country name, code | — | X | — |
| SG13.CTA | — | — | Must | — |
3139 IC05160 | Information contact | — | X | — |
| SG13.COM | — | — | Must | — |
314805170 | Number / address | — | X | — |
3155 TE05180 | Telephone | — | X | [1P0..1] |
3155 EM05190 | Electronic mail | — | X | [1P0..1] |
| SG12.NAD | — | — | Must | — |
3035 Z0305200 | Metering location address | — | X | — |
312405210 | Additional information for identification | — | — | — |
304205220 | Street and house number or PO box | — | — | S [166] M [212] |
316405230 | City | — | X | — |
325105240 | Postal code | — | X | — |
320705250 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1905260 | Metering location | — | X | — |
115405270 | ID of a metering location | — | X | [951] |
| SG12.NAD | — | — | Must | — |
3035 Z0505280 | Name and address for the meter reading card | — | X | — |
303605290 | Name | — | X | — |
3045 Z0105300 | Structure of person names | — | X | — |
3045 Z0205310 | Structure of the company name | — | X | — |
304205320 | Street and house number or PO box | — | X | — |
316405330 | City | — | X | — |
325105340 | Postal code | — | — | M [268] S [166] |
320705350 | Country name, code | — | X | — |
| SG12.RFF | — | — | Must | — |
1153 Z1905360 | Metering location | — | X | — |
115405370 | ID of a metering location | — | X | [951] |
| UNT | — | — | Must | — |
007405380 | Number of segments in a message | — | X | — |
006205390 | Message reference number | — | X | — |
Conditions of this table
The free text of the 105 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [32] | If more than one SG8 (reference to the location bundle structure) is present |
| [58] | If in this CCI the DE3055 with the code 293 is present |
| [78] | If SG4 STS+7++E02 (transaction reason: move-in to creation) is not present |
| [81] | If in the same SG8 SEQ+Z61/ZB3/ZB4 (product data of the controllable resource) the SG10 CCI+11 (details on the product of the controllable resource) is not present |
| [90] | If SG10 CCI+++ZA6 (forecast basis of the market location: forecast based on profiles) present once with CAV+E14 (TLP/TEP) and once with CAV+E02 (SLP/SEP) in this SG8 |
| [95] | If in the same SG10 the CCI+Z17 (type of electricity consumption ) CAV+ZE5 (e-mobility) is present |
| [103] | If SG9 QTY+265 (energy / power for day-parameter-dependent market location: estimated annual quantity total) present in this SG8 |
| [104] | If SG9 QTY+Z08 (energy / power for day-parameter-dependent market location: adjusted electrical energy according to Annex D) present in this SG8 |
| [136] | If SG10 CCI+++E13 (meter type) CAV+EHZ (electronic household meter) present in this SG8 |
| [139] | If SG10 CAV+IVA (individual reconciliation) not present in this SG8 |
| [141] | If SG10 CAV+MIW/MPW/MBW present |
| [159] | If in the same SG8 SEQ+Z57 (OBIS data of the grid location) the SG10 CCI+11 (OBIS data of the grid location) is not present |
| [166] | If present |
| [173] | If DE1156 (consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is not present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [174] | If DE1156 consecutive number of a location bundle in the business transaction) in the RFF+Z33 (reference to the object code in the location bundle structure) is present in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle) |
| [175] | If the object code in RFF+Z33 (reference to the object code in the location bundle struct ure) in DE1154 of the same SG8 SEQ+Z58 (assignment of location to the object code of the location bundle) is present in a further SG8 SEQ+Z58 with the same sequential number |
| [176] | If DE1153 with code Z34 upstream metering location is present in the same segment |
| [177] | If DE1153 with code Z35 upstream grid location is present in the same segment |
| [178] | If the LOC+Z18 (grid location) is present |
| [179] | If the object code in RFF+Z33 (reference to the object code in the location bundle struc ture) in DE1154 of the same SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle ) is present in a further SG8 SEQ+Z58/ZC9 / ZD0/ZD6 (assignment of location to the object code of the location bundle ) with an identical code in DE1229 |
| [184] | If in the same SG8 SEQ+Z18 (data of the metering location) a CCI+Z01++Z82 (scope of use: ID of the metering location handled in the process) is present |
| [210] | If SG10 CCI+++ZA6 (forecast based on profiles) present in this SG8 |
| [212] | If NAD DE3124 is not present in the same SG12 |
| [215] | If in the same SG8 (metering device data) SG10 CCI+++E13 CAV+MME (meter type: mME) is present |
| [221] | If no SG8 SEQ+Z15 (data of the tranche) references the same market location ID with the RFF+Z18 (market location) as this SG8 SEQ+Z01 (data of the market location) |
| [234] | If SG10 CCI+++Z83 (metering classification of the market location) CAV+Z53 (kME/mME) is present |
| [239] | If in the same SG10 the CCI+Z17 (type of electricity consumption ) is present in the CAV+Z65 (heat/cooling) |
| [249] | Within one SG4 IDE, all DE1131 of the SG4 STS+E01 (status of the response) must contain the identical value |
| [268] | If an "X" is listed for the code in DE3207 in the column "PLZ present" of the "EDI@Energy code list of European country codes" |
| [291] | If in the same SG8 (assignment of location to the object code of the location bundle ) the RFF+Z37 is present |
| [314] | All OBIS codes in accordance with the code list of OBIS codes and media, chapter 3, that are required at the market location must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document Code list of configurations |
| [323] | All OBIS codes in accordance with EDI@Energy code list of OBIS codes and media for the German energy market, chapter 3., that are used at the metering device must be stated. The minimum scope of the OBIS codes results from the metering product codes stated in chapter 5.1 of the document "Code list of configurations" |
| [333] | If in this RFF "reference to the location bundle structure" the code Z31 "location bundle structure" is present in DE1153 |
| [346] | If SG10 CCI+++E13 (meter type) CAV+MME (mME) present in this SG8 |
| [353] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/NeLo“ column and in the „Usable for market role/NB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [354] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/NeLo“ column and in the „Usable for market role/LF“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [381] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/NB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [382] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/LF“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [383] | Only codes from the „Code“ column of the code list of purposes of use (chapter 2) are permitted, provided that an „X“ is set in the same row both in the „Location/MaLo“ column and in the „Usable for market role/ÜNB“ column and the statements in the „Explanation“ column match the OBIS code specified in DE7140 of the same PIA |
| [402] | If in the same SG8 (OBIS data of the metering device / smart meter gateway) an OBIS code of the value type "meter reading" is present in the PIA+5 |
| [412] | Only configuration product codes from the "EDI@Energy code list of configurations", chapter 4.2 Configuration products power curve definition, are permitted |
| [417] | If no metering time period is required for the required value |
| [420] | If the RFF+Z14 (smart meter gateway) is present in this SG8 |
| [425] | Metering product code from chapter 2.1 "Standard metering products of the market location" of the code list of configurations |
| [426] | Metering product code from chapter 2.2 "Standard metering products of the tranche" of the code list of configurations |
| [427] | Metering product code from chapter 2.3 "Standard metering products of the metering location" of the code list of configurations |
| [429] | If in the same SG8 SEQ+Z19/ZF4 (required metering product of the metering location) the PIA+5 DE7140 with a metering product from the code list of configurations chapter 2.3.1 standard metering product of the metering location with the option of assigning a |
| [438] | If code Z39 (code of the metering time period) is present in DE7059 in the same CCI |
| [440] | If code Z35 (upstream grid location) is present in DE1153 in the same RFF |
| [441] | If RFF+Z14 (reference to the smart meter gateway) is not present in the SG8+SEQ+Z03/ZF5 (metering device data) for the device number of a meter named in this RFF DE1154 |
| [442] | If code Z34 (upstream metering location) is present in DE1153 in the same RFF |
| [446] | If in the same SG8 the CCI+Z17 (type of electricity consumption ) is present |
| [447] | If in the same SG8 the CCI+Z50 (type of electricity generation ) is present |
| [448] | If in the same SG8 the CCI+Z56 (storage) is present |
| [450] | If code Z32 (grid location) is present in DE1153 in the same RFF |
| [451] | If code Z18 (market location) is present in DE1153 in the same RFF |
| [452] | If code Z19 (metering location) is present in DE1153 in the same RFF |
| [456] | If code Z37 (technical resource) is present in DE1153 in the same RFF |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [611] | Note: If the company NB performs the tasks of the market role LF, the MP-ID of the company NB in the market role LF is to be stated |
| [621] | Note: The MSB must be specified that is assigned to the location from the point in time named in DTM+76 (date of the planned start of supply). |
| [622] | Note: If the OBIS code is relevant for several market roles, the segment group must be repeated for each market role |
| [651] | Note: The market locations for which the OBIS named here is required must be specified |
| [665] | Note: If a meter is parameterized with a SMGW, no OBIS code numbers are stated for that meter. Only OBIS code numbers from the SMGW exist here |
| [699] | Note: The ID of the controllable resource via which the technical resource is controlled must be specified |
| [700] | Note: The ID of the grid location via which the technical resource is controlled must be specified |
| [701] | Note: The Malo ID of the tranche to which the technical resource is assigned must be specified |
| [902] | Format: Possible value: ≥ 0 |
| [914] | Format: Possible value: > 0 |
| [922] | Format: TR-ID |
| [930] | Format: max. 2 decimal places |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [950] | Format: market location ID |
| [951] | Format: Metering point identifier |
| [952] | Format: device number according to DIN 43863-5 |
| [955] | Format: Possible value: < 100 |
| [960] | Format: Grid location ID |
| [961] | Format: SR-ID |
| [2182] | Segment group must be specified exactly once per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2183] | Segment group must be specified exactly twice per SG8 SEQ+Z01/Z80/Z81/Z98 (data of the market location/expected data of the market location/data of the market location present in the system) |
| [2236] | Code once per SG4 IDE+24 (transaction) |
| [2312] | If the object code "9992000001256" (grid location) is not present in DE1154 of the same RFF+Z33, the RFF+Z33 must be specified exactly once in the same SG8 SEQ+Z58/ZC9/ZD0/ZD6 (assignment of location to the object code of the location bundle ) |
| [2317] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MIW/MPW/MUW is present, the segment must be specified at least twice |
| [2318] | If in the same SG8 SEQ+Z04/ZF7 (transformer data) the SG10 CCI+++Z25 (transformer) CAV+MBW (block current transformer ) is present, the segment must be specified exactly once |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [19P1..1] | [20] If in the SG8 SEQ+Z01 (data of the market location) with the same ID in SG8 RFF+Z18 (reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) is present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of configurations chapter 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 30 ] If another SG8 SEQ+Z27 (Required metering product of the market location), which with the RFF+Z18 (reference to the ID of the market location) references the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [20P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 31 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [22P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [26P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [4 30 ] If another SG8 SEQ+Z27 (Required metering product the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 ( for active energy load curve 1/4-hourly) is present [436] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000086 :Z11 (active energy highest 1/4 hour in the month) is present |
| [21P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [22P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [23P0..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [24P0..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [27P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 31 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [23P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [24P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [4 33 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [38P1..1] | [419] If no other package in this SG10 in the same SG8 SEQ leads to the possibility of specifying at least one other code in this data element |
| [19P0..1] | [20] If in the SG8 SEQ+Z01 (data of the market location) with the same ID in SG8 RFF+Z18 (reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) is present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of configurations chapter 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 30 ] If another SG8 SEQ+Z27 (Required metering product of the market location), which with the RFF+Z18 (reference to the ID of the market location) references the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [20P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 31 ] If no other SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present |
| [26P0..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [4 30 ] If another SG8 SEQ+Z27 (Required metering product the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 ( for active energy load curve 1/4-hourly) is present [436] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000086 :Z11 (active energy highest 1/4 hour in the month) is present |
| [21P1..1] | [20] If in the SG8 SEQ+Z01 (Data of the market location) with the same ID in the SG8 RFF+Z18 (Reference to the ID of the market location) as in this SG8 the SG10 CCI+Z30++Z07 (consumption) present [ 432 ] If in the same SG8 SEQ+Z27 (Required metering product of the market location), the PIA+5+ 9991000000078 :Z11 (active energy load curve 1/4-hourly) is present [ 435 ] If another SG8 SEQ+Z27 (Required metering product of the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present |
| [25P1..1] | [54] If SG8 SEQ+Z01 (Data of the market location) SG10 CCI+Z30++Z06 (delivery direction: generation) present [ 428 ] If in the same SG8 SEQ+Z27 / ZE2 (Required metering product of the market location) the PIA+5 DE7140 with a metering product from the code list of the configurations Kapitel 2.1.1 Standard metering product of the market location with the option of assigning a metering time period is present [4 30 ] If another SG8 SEQ+Z27 (Required metering product the market location), with the RFF+Z18 (Reference to the ID of the market location) referencing the same ID of a market location, with PIA+5+ 9991000000078 :Z11 ( for active energy load curve 1/4-hourly) is present |
| [1P1..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
Example message
UNA:+.? '
UNB+UNOC:3+9904446000007:500+9900321000005:500+{{date}}:{{time}}+M40MMDV8'
UNH+UNHM3WASW1U+UTILMD:D:11A:UN:S2.2'
BGM+E01+BGMM3I58NYT'
DTM+137:202610021100?+00:303'
NAD+MS+9904446000007::293'
NAD+MR+9900321000005::293'
IDE+24+123456'
DTM+76:202606302200?+00:303'
STS+7++E02'
STS+E01++E15:S_0063'
LOC+Z16+50074561188'
LOC+Z17+DE0032106765712000000000000000037'
RFF+Z13:55169'
RFF+TN:ABC123456'
RFF+Z50:50074561188'
DTM+752:0101:106'
SEQ+Z78'
RFF+Z31:9992000000026'
SEQ+Z58'
RFF+Z18:50074561188'
RFF+Z33:9992000001016'
SEQ+Z58'
RFF+Z19:DE0032106765712000000000000000037'
RFF+Z33:9992000001032'
SEQ+Z01'
RFF+Z18:50074561188'
QTY+31:2000:KWH'
CCI+Z30++Z07'
CCI+++ZB3'
CAV+Z90:4045399000077'
CAV+Z91:4045458000017::Z39:Z20'
CCI+++E03'
CAV+E06'
CCI+++Z83'
CAV+Z53'
CCI+6++ZA8'
CCI+++ZA6'
CAV+E02'
CCI+ZA2++ZE9'
SEQ+Z27'
RFF+Z18:50074561188'
PIA+5+9991000000044:Z11'
CCI+Z41'
CCI+++ZA8'
CAV+ZE1'
CCI+++ZA7'
CAV+ZE1'
SEQ+Z02'
RFF+Z18:50074561188'
PIA+5+1-1?:1.9.0:SRW+:V14:Z16+:V14:Z16+:V15:Z16'
CCI+++ZE4'
CAV+ZD9'
SEQ+Z18'
RFF+Z19:DE0032106765712000000000000000037'
CCI+++ZB3'
CAV+Z91:4045458000017::Z39:Z20'
CAV+ZF0:9904446000007'
CAV+ZB4:9904446000007'
CCI+++E04'
CAV+E06'
CCI+Z01++Z82'
CCI+Z32++ZC3'
SEQ+Z19'
RFF+Z19:DE0032106765712000000000000000037'
RFF+Z18:50074561188'
PIA+5+9991000000151:Z11'
CCI+Z35'
CAV+ZC9:::Z07'
CAV+Z88:::Z07'
CCI+Z41'
SEQ+Z21'
RFF+Z18:50074561188'
CCI+Z02++E01'
CAV+H0'
NAD+Z07+++Mustermann:Max::::Z01'
RFF+Z19:DE0032106765712000000000000000037'
NAD+Z08+++Mustermann:Max::::Z01+Straße::1+Ort++12345+DE'
CTA+IC'
COM+max@mustermann.de:EM'
NAD+Z03++Mustermann:Max++Straße::1+Ort++12345+DE'
RFF+Z19:DE0032106765712000000000000000037'
NAD+Z05+++Mustermann:Max::::Z01+Straße::1+Ort++12345+DE'
RFF+Z19:DE0032106765712000000000000000037'
UNT+83+UNHM3WASW1U'
UNZ+1+M40MMDV8'[1 item
{6 fields
"data": {3 fields
"stammdaten": {6 fields
"MARKTLOKATION": [1 item
{10 fields
"marktlokationsTyp": [1 item
{1 field
"marktrollen": [3 items
{6 fields
{6 fields
{8 fields
"zaehlwerke": [1 item
{7 fields
"zaehlzeiten": {1 field
"MESSLOKATION": [1 item
{12 fields
"messadresse": {6 fields
"zusatzInformation": {2 fields
"zaehlwerke": [1 item
{4 fields
"zaehlzeiten": {1 field
"ablesekartenempfaenger": {7 fields
"geschaeftspartnerrolle": [1 item
"partneradresse": {5 fields
"marktrollen": [3 items
{8 fields
{6 fields
{6 fields
"LOKATIONSBUENDEL": [1 item
{5 fields
"zuordnungObjectcode": [2 items
{3 fields
"objectcode": [1 item
{1 field
{3 fields
"objectcode": [1 item
{1 field
"NETZNUTZUNGSVERTRAG": [1 item
{6 fields
"MESSSTELLENBETRIEBSVERTRAG": [1 item
{9 fields
"vertragspartner2": [1 item
{6 fields
"geschaeftspartnerrolle": [1 item
"vertragskonditionen": {1 field
"geplanteTurnusablesung": {1 field
"korrespondenzpartner": {7 fields
"partneradresse": {5 fields
"ansprechpartner": {3 fields
"BILANZIERUNG": [1 item
{9 fields
"lastprofile": [1 item
{5 fields
"jahresverbrauchsprognose": {2 fields
"detailsPrognosegrundlage": [1 item
"transaktionsdaten": {15 fields
"absender": {5 fields
"empfaenger": {5 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB and MSB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | NB | End of metering point operation | WiM electricity part 1 | Electricity | Step 4 |
| MSB | GMSB | End of metering point operation | WiM electricity part 1 | Electricity | Step 4 |
| MSB | MSBA | End of metering point operation | WiM electricity part 1 | Electricity | Step 4 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Confirmation of commitment request |
| AHB | UTILMD AHB electricity |
| Decision tree | E_0240 |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| WiM electricity part 1 | End of metering point operation | MSB (corresponds to gMSB on the object metering location) → NB | Response to commitment request |
Transaction and responses
Role of this check identifier: response — confirmation. Basis: the transaction data carry antwortstatus and antwortstatusCodeliste; the title or the action of the Prüfi table begins with “response”; the title names a polarity (confirmation).
Which request this message responds to
| Role | Check identifier | Use case | Message type | Origin of supply |
|---|---|---|---|---|
| Request | 55168 | Commitment request / demand | UTILMD | from the step sequence |
In which field the request is quoted
| Reference field of this message | EDIFACT segment | Target field in the request |
|---|---|---|
anfragereferenznummer | SG4.IDE+24.SG6.RFF+TN | vorgangsnummer |
For RFF+TN, the time slice field description gives »reference transaction number (from request message)« — the target is the vorgangsnummer in segment SG4.IDE+24 of the request. Measured: 55168 lists vorgangsnummer in SG4.IDE+24.
Response codes
Decision trees: S_0063 · E_0240.
The Prüfi table names one further tree across all rows of this check identifier. They tie it to a process, not to a row of its handbook — their codes are therefore only on the respective tree page. For S_0063 there is no decision tree in version 202610; its response codes are therefore not given here.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDS has the same row structure in this version.
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 755 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains one transaction for this check identifier under the message type utilmd. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.