Check identifier 55203 — Activation of ZP for monthly AAÜZ
Check identifier 55203 · EDIFACT message type UTILMD · format version 202610
This page is derived from the application handbook
The MACO APP does not carry this check identifier. The complete Prüfi pages of this level are produced from the specifications of the application — one class in the templater per check identifier — and that is where the assignment to the business objects (BO4E) comes from: which object carries which field of the message.
The catalogue of the application handbook is the larger set. This page therefore shows what the handbook itself provides — use case, process context and the AHB field list with its conditions. A data structure according to BO4E is not shown, and not because there is none, but because the application does not form one for this check identifier.
All check identifiers in this situation — and the corresponding figures — are listed by the overview of this version.
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55203 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.200060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 Z0700070 | Activation/ deactivation of MaBiS-ZP | — | X | — |
100400080 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700090 | Document/message date/time | — | X | — |
238000100 | Date or time or time span, value | — | X | [931] [494] |
2379 30300110 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00120 | Document-/ message sender or sender | — | X | — |
303900130 | MP-ID | — | X | — |
3055 900140 | GS1 | — | X | — |
3055 29300150 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MR00160 | Message recipient | — | X | — |
303900170 | MP-ID | — | X | [280] |
3055 900180 | GS1 | — | X | — |
3055 29300190 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400200 | Transaction | — | X | — |
740200210 | Transaction number | — | X | — |
| SG4.DTM | — | — | Must | — |
2005 15800220 | Start of balancing | — | X | — |
238000230 | Date or time or time span, value | — | X | [UB1] |
2379 30300240 | CCYYMMDDHHMMZZZ | — | X | — |
| SG5.LOC | — | — | Must | — |
3227 Z1500250 | MaBiS metering point | — | X | — |
322500260 | Identifier | — | X | [951] |
| SG6.RFF | — | — | Must | — |
1153 Z1300270 | Check identifier | — | X | — |
1154 5520300280 | Redispatch / activation ZP monthly AAÜZ | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2400290 | Data of the transfer time series | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 1500300 | Structure | — | X | — |
7037 Z2100310 | Aggregated time series type | — | X | — |
| SG10.CAV | — | — | Must | — |
711100320 | Code of the transfer time series type | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1800330 | Control area | — | X | — |
703700340 | Control area | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z2800350 | Balancing group "to" | — | X | — |
703700360 | Balancing group | — | X | [645] |
| SG10.CCI | — | — | Must | — |
7059 Z2900370 | Balancing group "from" | — | X | — |
703700380 | Balancing group | — | X | [646] |
| SG10.CCI | — | — | Must | — |
7059 Z2000390 | Balancing area | — | X | — |
703700400 | Balancing area | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 Z2500410 | Product data of the transfer time series | — | X | — |
| SG8.PIA | — | — | Must | — |
4347 500420 | Product identification | — | X | — |
714000430 | Product identification of the transfer time series | — | X | [254] |
7143 Z0800440 | Medium | — | X | — |
| UNT | — | — | Must | — |
007400450 | Number of segments in a message | — | X | — |
006200460 | Message reference number | — | X | — |
Conditions of this table
The free text of the 8 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [254] | The code "AUA" must be entered |
| [280] | Only MP-ID from the electricity division |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [645] | Note: The balancing group of the LF must be specified |
| [646] | Note: The RD balancing group of the ANB must be specified |
| [931] | Format: ZZZ = +00 |
| [951] | Format: Metering point identifier |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are NB, BIKO and BKV.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| NB | ANB | Activation of a MaBiS-ZP for the monthly curtailed energy transfer time series (AAÜZ) between NB and BKV (of the LF) | MaBiS | Electricity | Step 1 |
| BIKO | BIKO | Activation of a MaBiS-ZP for the monthly curtailed energy transfer time series (AAÜZ) between NB and BKV (of the LF) | MaBiS | Electricity | Step 1 |
| BKV | BKV-LF | Activation of a MaBiS-ZP for the monthly curtailed energy transfer time series (AAÜZ) between NB and BKV (of the LF) | MaBiS | Electricity | Step 1 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Activation ZP monthly AAÜZ |
| AHB | UTILMD AHB electricity |
| Transmission channel | AS4 |
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| MaBiS | Activation of a MaBiS-ZP for the monthly curtailed energy transfer time series (AAÜZ) between NB and BKV (of the LF) | NB (ANB) → BIKO | Activation of a MABIS-ZP for the monthly AAÜZ |
Notes on this page
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 65 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.