Check identifier 55623 — Response message/request for data of TR
Check identifier 55623 · EDIFACT message type UTILMD · format version 202604
Data structure
| Structure (BO4E) | Description | Format | 55623 | Condition |
|---|---|---|---|---|
| stammdaten * | — | object | Must | — |
| TECHNISCHE_RESSOURCE [ ] * | — | object[] | Must | — |
| art 00010 | Technical resource type | Enum TechnischeRessourceArt | Must | — |
STROMERZEUGUNG | — | — | Must | — |
STROMVERBRAUCH | — | — | Must | — |
SPEICHER | — | — | Must | — |
| artEMobilitaet 00020 | ArtEmobilitaet | Enum ArtEmobilitaet | Should | [8] |
WB | — | — | Should | — |
LS | — | — | Should | — |
LP | — | — | Should | — |
| datenqualitaet 00030 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| einordnung 00040 | RessourceWechselmoeglichkeit | Enum RessourceWechselmoeglichkeit | Should | [8] |
WECHSELMOEGLICHKEIT_EINMALIG_NOCH_MOEGLICH | — | — | Should | — |
WECHSELMOEGLICHKEIT_NICHT_MOEGLICH | — | — | Should | — |
BEFRISTET_OHNE_WECHSELMOEGLICHKEIT | — | — | Should | — |
WECHSEL_WURDE_DURCHGEFUEHRT | — | — | Should | — |
| enwg 00050 | enwg | boolean | Should | [8] |
| erzeugungsart 00060 | Type of energy generation. Details generation type Example: CAV+ZF5' Generation type: ZF5: solar ZF6: wind ZG0: gas ZG1: water ZG5: other generation type | Enum Erzeugungsart | Should | [8] |
EEG | — | — | Should | — |
KWK | — | — | Should | — |
EEG_DV | — | — | Should | — |
KWK_DV | — | — | Should | — |
WIND | — | — | Should | — |
SOLAR | — | — | Should | — |
KERNKRAFT | — | — | Should | — |
WASSER | — | — | Should | — |
GEOTHERMIE | — | — | Should | — |
BIOMASSE | — | — | Should | — |
KOHLE | — | — | Should | — |
GAS | — | — | Should | — |
SONSTIGE | — | — | Should | — |
SONSTIGE_EEG | — | — | Should | — |
SONSTIGE_ERZEUGUNGSART | — | — | Should | — |
| inbetriebsetzungsdatum 00070 | Commissioning | Enum Inbetriebsetzung | Should | [8] |
INBETRIEBSETZUNG_NACH_2023 | — | — | Should | — |
INBETRIEBSETZUNG_VOR_2024 | — | — | Should | — |
| referenzNetzlokation 00080 | referenzNetzlokation | string | X | — |
| referenzSteuerbareRessource 00090 | referenzSteuerbareRessource | string | X | — |
| ressourcenId * 00100 | ressourcenId | string | X | — |
| speicherart 00110 | Type of storage. Details storage type Example: CAV+ZF7' Storage type: ZF7: hydrogen storage ZF8: pumped storage ZF9: battery storage ZG6: other storage type | Enum Speicherart | Should | [8] |
WASSERSTOFFSPEICHER | — | — | Should | — |
PUMPSPEICHER | — | — | Should | — |
BATTERIESPEICHER | — | — | Should | — |
SONSTIGE_SPEICHERART | — | — | Should | — |
| speicherkapazitaet 00120 | Storage capacity Example: QTY+Z42:100:KWH' | number (float) | X | — |
| verbrauchsart 00130 | Consumption type of the technical resource Example: CAV+Z64' Z64: Power/light Z65: Heat ZE5: E-mobility ZA8: Street lighting | array | Should | [8] |
| waermenutzung 00140 | Heat usage Example: CAV+Z56' Z56: Storage heating Z57: Heat pump Z61: Direct heating | Enum Waermenutzung | Should | [8] |
SPEICHERHEIZUNG | — | — | Should | — |
WAERMEPUMPE | — | — | Should | — |
DIREKTHEIZUNG | — | — | Should | — |
WAERMEPUMPE_WAERME_KAELTE | — | — | Should | — |
WAERMEPUMPE_KAELTE | — | — | Should | — |
WAERMEPUMPE_WAERME | — | — | Should | — |
| weitereEinrichtung 00150 | weitereEinrichtung | boolean | Should | [8] |
| gueltigkeitszeitraum | — | object | May | — |
| zeitraumId 00160 | zeitraumId | integer | Must | — |
| nennleistung | — | object | May | — |
| abgabe 00170 | Submission of the rated capacity | number (float) | X | — |
| aufnahme 00180 | Recording of the rated power | number (float) | X | — |
| VERWENDUNGSZEITRAUM [ ] | — | object[] | May | — |
| datenqualitaet 00190 | Data quality | Enum Datenqualitaet | Must | — |
ERWARTETE_DATEN | — | — | Must | — |
IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
INFORMATIVE_DATEN | — | — | Must | — |
GUELTIGE_DATEN | — | — | Must | — |
KEINE_DATEN | — | — | Must | — |
IM_SYSTEM_KEINE_DATEN_VORHANDEN | — | — | Must | — |
KEINE_DATEN_ERWARTET | — | — | Must | — |
DIFFERENZ_DATEN | — | — | Must | — |
DIFFERENZ_ERWARTETE_DATEN | — | — | Must | — |
DIFFERENZ_IM_SYSTEM_VORHANDENE_DATEN | — | — | Must | — |
| verwendungAb 00200 | verwendungAb | string (date-time) | X | — |
| verwendungBis 00210 | verwendungBis | string (date-time) | X | — |
| zeitraumId 00220 | zeitraumId | integer | Must | — |
| transaktionsdaten * | — | object | Must | — |
| anfragereferenznummer 00230 | Reference transaction number 'from request message' / ORDERS RFF+TN / IFTSTA RFF+AAV / INSRPT RFF+TN RFF+AAV | string | X | — |
| dokumentennummer * 00240 | EDIFACT reference from the BGM segment / BGM | string | Must | — |
| kategorie * 00250 | Qualifier from the beginning of the EDIFACT message / BGM | string | Must | — |
| nachrichtendatum * 00260 | Creation date of the EDIFact / DTM+137 | string (date-time) | X | — |
| nachrichtenreferenznummer * 00270 | EDIFACT reference from the UNT segment / UTILMD UNT+21 | string | Must | — |
| pruefidentifikator * 00280 | Contains the check identifier from the EDIFact communication / RFF+Z13 | string | X | — |
| transaktionsgrund * 00290 | The transaction reason describes the business transaction for the category in more detail / UTILMD STS+7++###+ZW4+E03 | string | X | — |
| vorgangsnummer * 00300 | Number of the transaction / UTILMD UTILTS IDE+24 / INSRPT INVOIC DOC | string | X | — |
| absender * | — | object | Must | — |
| rollencodenummer * 00310 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00320 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
| ansprechpartner | — | object | May | — |
| eMailAdresse 00330 | Email address | string | Must | — |
| nachname 00340 | Surname (family name) of the contact person | string | Must | — |
| rufnummern [ ] | — | object[] | May | — |
| nummerntyp 00350 | Phone number type | Enum Rufnummernart | Must | — |
RUF_ZENTRALE | — | — | Must | — |
FAX_ZENTRALE | — | — | Must | — |
SAMMELRUF | — | — | Must | — |
SAMMELFAX | — | — | Must | — |
ABTEILUNGRUF | — | — | Must | — |
ABTEILUNGFAX | — | — | Must | — |
RUF_DURCHWAHL | — | — | Must | — |
FAX_DURCHWAHL | — | — | Must | — |
MOBIL_NUMMER | — | — | Must | — |
| rufnummer 00360 | rufnummer | string | Must | — |
| antwortStatusZeitraum [ ] | — | object[] | May | — |
| code 00370 | code | string | X | — |
| liste 00380 | liste | string | X | — |
| zeitraumId 00390 | zeitraumId | integer | X | — |
| empfaenger * | — | object | Must | — |
| rollencodenummer * 00400 | Specifies the code value of the market role. | string | X | — |
| rollencodetyp * 00410 | Indicates the type of the code. | Enum Rollencodetyp | X | — |
BDEW | — | — | X | — |
GS1 | — | — | X | — |
GLN | — | — | X | — |
DVGW | — | — | X | — |
Application handbook (AHB)
| Structure (EDIFACT) | Description | Format | 55623 | Condition |
|---|---|---|---|---|
| UNH | — | — | Must | — |
006200010 | Message reference number | — | X | — |
0065 UTILMD00020 | Grid connection master data | — | X | — |
0052 D00030 | Draft version | — | X | — |
0054 11A00040 | Edition 2011 - A | — | X | — |
0051 UN00050 | UN/CEFACT | — | X | — |
0057 S2.100060 | Version number of the underlying BDEW message description | — | X | — |
| BGM | — | — | Must | — |
1001 E0300070 | Change notifications | — | X | [705] |
1001 Z8800080 | Request for data clearing | — | X | [706] |
100400090 | Document number | — | X | — |
| DTM | — | — | Must | — |
2005 13700100 | Document-/message date/time | — | X | — |
238000110 | Date or time or time span, value | — | X | [931] [494] |
2379 30300120 | CCYYMMDDHHMMZZZ | — | X | — |
| SG2.NAD | — | — | Must | — |
3035 MS00130 | Document-/message sender or sender | — | X | — |
303900140 | MP-ID | — | X | — |
3055 900150 | GS1 | — | X | — |
3055 29300160 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG3.CTA | — | — | Must | — |
3139 IC00170 | Information contact | — | X | — |
341200180 | Name of the contact person | — | X | — |
| SG3.COM | — | — | Must | — |
314800190 | Number / address | — | X | (([939] [321]) ∨ ([940] [322])) ∧ [514] |
3155 EM00200 | Electronic mail | — | X | [1P0..1] |
3155 FX00210 | Fax number | — | X | [1P0..1] |
3155 TE00220 | Telephone | — | X | [1P0..1] |
3155 AJ00230 | further telephone | — | X | [1P0..1] |
3155 AL00240 | Mobile phone | — | X | [1P0..1] |
| SG2.NAD | — | — | Must | — |
3035 MR00250 | Message recipient | — | X | — |
303900260 | MP-ID | — | X | — |
3055 900270 | GS1 | — | X | — |
3055 29300280 | DE, BDEW (Bundesverband der Energie- und Wasserwirtschaft e.V.) | — | X | — |
| SG4.IDE | — | — | Must | — |
7495 2400290 | Transaction | — | X | — |
740200300 | Transaction number | — | X | — |
| SG4.STS | — | — | Must | — |
9015 700310 | Transaction reason | — | X | — |
9013 ZY000320 | Change data of the TR | — | X | — |
| SG4.STS | — | — | Must | [301] ∧ [557] ∧ [2011] |
9015 E0100330 | Status of the response | — | X | — |
901300340 | Code of the check step | — | X | — |
1131 E_040800350 | EBD no. E_0408 | — | X | — |
901200360 | Time period ID from the change notification of the responsible party | — | X | [914] ∧ [937] ∧ [44] |
| SG5.LOC | — | — | Must | — |
3227 Z2000370 | Technical resource | — | X | — |
322500380 | ID of the technical resource | — | X | [922] |
| SG6.RFF | — | — | Must | — |
1153 Z1300390 | Check identifier | — | X | — |
1154 5562300400 | GPKE / Response message / Request for data of the TR from LF to NB | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 TN00410 | Transaction reference number | — | X | — |
115400420 | Transaction number | — | X | — |
| SG6.RFF | — | — | Must | — |
1153 Z4700430 | Data available in the system | — | X | [5P0..n] |
1153 Z4800440 | Expected data | — | X | [2P0..n] |
1153 Z5400450 | No data available in the system | — | X | [4P0..n] |
1153 Z5500460 | No data expected | — | X | [2P0..n] |
115600470 | Time period ID | — | X | [914] ∧ [937] [127] ⊻ [128] |
| SG6.DTM | — | — | Must | [131] ⊻ [134] ⊻ [135] |
2005 Z2500480 | Data used from | — | X | — |
238000490 | Date or time or time span, value | — | X | [UB1] |
2379 30300500 | CCYYMMDDHHMMZZZ | — | X | — |
| SG6.DTM | — | — | Must | [472] ⊻ [473] |
2005 Z2600510 | Data used until | — | X | — |
238000520 | Date or time or time span, value | — | X | [UB1] |
2379 30300530 | CCYYMMDDHHMMZZZ | — | X | — |
| SG8.SEQ | — | — | Must | — |
1229 ZG400540 | Expected data of the technical resource | — | X | [2P0..n] |
1229 ZG500550 | Data of the technical resource available in the system | — | X | [3P0..n] |
105000560 | Reference to time period ID | — | X | [914] ∧ [937] [22] |
| SG8.RFF | — | — | Should | [8] |
1153 Z3800570 | Controllable resource | — | X | — |
115400580 | ID of the controllable resource | — | X | [961] |
| SG8.RFF | — | — | Should | [8] |
1153 Z3200590 | Grid location | — | X | — |
115400600 | ID of the grid location | — | X | [960] |
| SG9.QTY | — | — | Must | — |
6063 Z4300610 | Rated power (input) | — | X | — |
606000620 | Quantity | — | X | — |
6411 KWT00630 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4400640 | Rated power (output) | — | X | — |
606000650 | Quantity | — | X | — |
6411 KWT00660 | Kilowatt | — | X | — |
| SG9.QTY | — | — | Must | — |
6063 Z4200670 | Storage capacity | — | X | — |
606000680 | Quantity | — | X | — |
6411 KWH00690 | Kilowatt hour | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z1700700 | Type of electricity consumption | — | X | — |
7059 Z5000710 | Type of electricity generation | — | X | — |
7059 Z5600720 | Storage | — | X | — |
| SG10.CAV | — | — | Should | [8] |
7111 Z6400730 | Power/light | — | X | [1P0..1] |
7111 Z6500740 | Heat/cold | — | X | [1P0..1] |
7111 ZE500750 | E-mobility | — | X | [1P0..1] |
7111 ZA800760 | Street lighting | — | X | [1P0..1] |
| SG10.CAV | — | — | Must | [239] |
7111 Z5600770 | Storage heating | — | X | — |
7111 Z5700780 | Heat pump (unspecified) | — | X | — |
7111 Z6100790 | Direct heating | — | X | — |
7111 ZV500800 | Heat pump (heat and cold) | — | X | — |
7111 ZV600810 | Heat pump (cold) | — | X | — |
7111 ZV700820 | Heat pump (heat) | — | X | — |
| SG10.CAV | — | — | Must | [95] |
7111 ZE600830 | Wallbox | — | X | — |
7111 Z8700840 | E-mobility charging station | — | X | — |
7111 ZE700850 | Charging park | — | X | — |
| SG10.CAV | — | — | Must | [447] |
7111 ZF500860 | Solar | — | X | — |
7111 ZF600870 | Wind | — | X | — |
7111 ZG000880 | Gas | — | X | — |
7111 ZG100890 | Water | — | X | — |
7111 ZG500900 | Other generation type | — | X | — |
| SG10.CAV | — | — | Must | [448] |
7111 ZF700910 | Hydrogen storage | — | X | — |
7111 ZF800920 | Pumped storage | — | X | — |
7111 ZF900930 | Battery storage | — | X | — |
7111 ZG600940 | Other storage type | — | X | — |
| SG10.CAV | — | — | Should | [8] |
7111 ZG800950 | Technical resource is covered by § 14a EnWG | — | X | — |
7111 ZG900960 | Technical resource is not covered by § 14a EnWG | — | X | — |
| SG10.CAV | — | — | Must | [461] |
7111 ZH000970 | Commissioning of the TR after 2023 | — | X | — |
7111 ZH100980 | Commissioning of the TR before 2024 | — | X | — |
| SG10.CAV | — | — | Must | [462] |
7111 ZH200990 | Option to change to the § 14a EnWG model pursuant to regulatory determination BK6-22-300 still available once | — | X | — |
7111 ZH301000 | Option to change to the § 14a EnWG model pursuant to regulatory determination BK6-22-300 not available | — | X | — |
7111 ZH401010 | Limited in time under the old § 14a EnWG model until 2028 without option to switch | — | X | — |
7111 ZH501020 | Change to the § 14a EnWG model pursuant to regulatory determination BK6-22-300 has been carried out | — | X | — |
| SG10.CCI | — | — | Must | — |
7059 Z6301030 | Information on further technical equipment | — | X | — |
| SG10.CAV | — | — | Must | — |
7111 ZH701040 | Further technical equipment present | — | X | — |
7111 ZH801050 | No further technical device available | — | X | — |
| UNT | — | — | Must | — |
007401060 | Number of segments in a message | — | X | — |
006201070 | Message reference number | — | X | — |
Conditions of this table
The free text of the 39 conditions referenced by the rows above. All conditions of the message type are listed in the condition index UTILMDS.
| Marker | Condition |
|---|---|
| [8] | If required for data clearing |
| [22] | The time period ID from DE1156 of a matching SG6 RFF+Z47/Z48/Z49 (usage period of the data) must be entered |
| [44] | The time period ID from DE1156 of a matching SG6 RFF+Z49/Z53 (usage period of the data: "valid data", "no data") from the request message from SG6 RFF+TN DE1154 ((reference transaction number (from request message)) must be entered |
| [95] | If in the same SG10 the CCI+Z17 (type of electricity consumption) CAV+ZE5 (e-mobility) is present |
| [127] | The value resulting from the number of repetitions of the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) must be entered. This means: the first SG6 RFF+Z48/Z55 thus has the „1“, the second the „2“, the third the „3“, etc. |
| [128] | The value resulting from the number of repetitions of the SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) must be entered. This means: the first SG6 RFF+Z47/Z54 thus has the „1“, the second the „2“, the third the „3“, etc. |
| [131] | If this DTM+Z25 (use of the data from) in SG6 RFF (usage period of the data) is marked with the time period ID "1" in DE1156, the date in this DE2380 must be the day immediately following DTM+137 DE2380 (message date) at 0:00, or a day earlier than that at 0:00 German time |
| [134] | If this DTM+Z25 (use of data from) is not in the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) with time period ID "1" in DE1156, the date must correspond to the DTM+Z26 (use of data until) of the SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) with the next lower time period ID in DE1156 |
| [135] | If this DTM+Z25 (use of data from) is not in the SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) with time period ID "1" in DE1156, the date must correspond to the DTM+Z26 (use of data until) of the SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) with the next lower time period ID in DE1156 |
| [239] | If in the same SG10 the CCI+Z17 (type of electricity consumption) is present in the CAV+Z65 (heat/cooling) |
| [301] | If BGM+E03 (change notification) present |
| [321] | If code EM is present in DE3155 in the same COM |
| [322] | If code TE / FX / AJ / AL is present in DE3155 in the same COM |
| [447] | If in the same SG8 the CCI+Z50 (type of electricity generation) is present |
| [448] | If in the same SG8 the CCI+Z56 (storage) is present |
| [461] | If in the same SG10 the CCI (type and use of the technical resource) is present in the CAV+ZG8 (technical resource falls under § 14a EnWG) |
| [462] | If in the same SG10 the CCI+Z17 (type of electricity consumption) is present in the CAV+ZH1 (commissioning of the TR before 2024) |
| [472] | If a time period ID is named in DE1156 (time period ID) in the same SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) which is lower than in another SG6 RFF+Z48/Z55 (usage period of the data: expected data/no data expected) DE1156 (time period ID) |
| [473] | If a time period ID is named in DE1156 (time period ID) in the same SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) which is lower than in another SG6 RFF+Z47/Z54 (usage period of the data: data present in the system/no data present in the system) DE1156 (time period ID) |
| [494] | The date stated here must be the point in time at which the document was created, or a point in time before that |
| [514] | Note: Only one piece of information may be transmitted in DE3148 |
| [557] | Note: If the responsible party has sent more than eight usage periods, eight arbitrary usage periods are answered |
| [705] | Note: If the action of a sequence diagram "Response message on change" is carried out |
| [706] | Note: If the action of a sequence diagram "Order placement of a change of master data..." is carried out with the aim of performing a data clearing |
| [914] | Format: Possible value: > 0 |
| [922] | Format: TR-ID |
| [931] | Format: ZZZ = +00 |
| [937] | Format: no decimal places |
| [939] | Format: the character string must contain the characters @ and . |
| [940] | Format: the character string must begin with the character + and may only be followed by digits |
| [960] | Format: Grid location ID |
| [961] | Format: SR-ID |
| [2011] | Segment group must be specified exactly once for each time period ID from DE1156 of the SG6 RFF+Z49 / Z53 (usage period of the data: "Valid data" / "No data") from the request message from SG6 RFF+TN DE1154 (reference transaction number (from request message)) |
| [1P0..1] | Note: This is the standard package if no condition applies, e.g. in the COM segment. |
| [5P0..n] | [315] If BGM+Z88 (data clearing) present [20 13 ] To be specified at least once , if no SG6 RFF+Z54 (Usage period of the data: no data present in the system) present |
| [2P0..n] | [301] If BGM+E03 (change notification) present [315] If BGM+Z88 (data clearing) present |
| [4P0..n] | [315] If BGM+Z88 (data clearing) present [20 14 ] To be specified at least once , if no SG6 RFF+Z47 (Usage period of the data: data present in the system) present |
| [UB1] | ([931] ∧ [932] [490]) ⊻ ([931] ∧ [933] [491]) |
| [3P0..n] | [315] If BGM+Z88 (data clearing) present |
Example message
Example 1
UNA:+.? '
UNB+UNOC:3+9903729000007:500+9900327000009:500+{{date}}:{{time}}+DAKCLQBFSBSJIP'
UNH+DADNFOGQPTEBRW+UTILMD:D:11A:UN:S2.1'
BGM+E03+DA702411120821109903323000007673578'
DTM+137:202506241231?+00:303'
NAD+MS+9903729000007::293'
CTA+IC+:P GETTY'
COM+?+3222271020:TE'
NAD+MR+9900327000009::293'
IDE+24+24062416225400000000000102159662011'
STS+7++ZY0'
STS+E01++A02:E_0408::1'
STS+E01++A02:E_0408::2'
LOC+Z20+D417MLM8164'
RFF+Z13:55623'
RFF+TN:TR1234'
RFF+Z48::1'
DTM+Z25:202506232200?+00:303'
DTM+Z26:202507232200?+00:303'
RFF+Z48::2'
DTM+Z25:202507232200?+00:303'
SEQ+ZG4+1'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z43:100:KWT'
CCI+Z17'
CAV+Z65'
CAV+ZV5'
CAV+ZG8'
CAV+ZH1'
CAV+ZH5'
CCI+Z63'
CAV+ZH8'
SEQ+ZG4+2'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z43:100:KWT'
CCI+Z17'
CAV+Z65'
CAV+ZV5'
CAV+ZG8'
CAV+ZH1'
CAV+ZH5'
CCI+Z63'
CAV+ZH8'
UNT+44+DADNFOGQPTEBRW'
UNZ+1+DAKCLQBFSBSJIP'[1 item
{6 fields
"data": {3 fields
"stammdaten": {3 fields
"VERWENDUNGSZEITRAUM": [2 items
{6 fields
{5 fields
"TECHNISCHE_RESSOURCE": [2 items
{16 fields
"gueltigkeitszeitraum": {3 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
{16 fields
"gueltigkeitszeitraum": {2 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
"STEUERBARE_RESSOURCE": [1 item
{4 fields
"transaktionsdaten": {13 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"rufnummern": [1 item
{2 fields
"empfaenger": {5 fields
"antwortStatusZeitraum": [2 items
{3 fields
{3 fields
Download: EDIFACT file · BO4E JSON
Example 2
UNA:+.? '
UNB+UNOC:3+9903729000007:500+9900327000009:500+{{date}}:{{time}}+DAPICHXGTOSYAJ'
UNH+DATCBYUYNRIHPR+UTILMD:D:11A:UN:S2.1'
BGM+E03+DA732411120825299903323000007662024'
DTM+137:202506241231?+00:303'
NAD+MS+9903729000007::293'
CTA+IC+:P GETTY'
COM+?+3222271020:TE'
NAD+MR+9900327000009::293'
IDE+24+24062416225400000000000102159662011'
STS+7++ZY0'
STS+E01++A02:E_0408::1'
STS+E01++A02:E_0408::2'
LOC+Z20+D417MLM8164'
RFF+Z13:55623'
RFF+TN:TR1234'
RFF+Z48::1'
DTM+Z25:202506232200?+00:303'
DTM+Z26:202507232200?+00:303'
RFF+Z48::2'
DTM+Z25:202507232200?+00:303'
SEQ+ZG4+1'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z44:100:KWT'
QTY+Z42:100:KWH'
CCI+Z56'
CAV+ZF7'
CAV+ZG8'
CAV+ZH1'
CCI+Z63'
CAV+ZH8'
SEQ+ZG4+2'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z44:100:KWT'
QTY+Z42:100:KWH'
CCI+Z56'
CAV+ZF7'
CAV+ZG8'
CAV+ZH1'
CCI+Z63'
CAV+ZH8'
UNT+42+DATCBYUYNRIHPR'
UNZ+1+DAPICHXGTOSYAJ'[1 item
{6 fields
"data": {3 fields
"stammdaten": {3 fields
"VERWENDUNGSZEITRAUM": [2 items
{6 fields
{5 fields
"TECHNISCHE_RESSOURCE": [2 items
{15 fields
"gueltigkeitszeitraum": {3 fields
"nennleistung": {1 field
{15 fields
"gueltigkeitszeitraum": {2 fields
"nennleistung": {1 field
"STEUERBARE_RESSOURCE": [1 item
{4 fields
"transaktionsdaten": {13 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"rufnummern": [1 item
{2 fields
"empfaenger": {5 fields
"antwortStatusZeitraum": [2 items
{3 fields
{3 fields
Download: EDIFACT file · BO4E JSON
Example 3
UNA:+.? '
UNB+UNOC:3+9903729000007:500+9900327000009:500+{{date}}:{{time}}+DADXWTWIXOZLUK'
UNH+DAVAXCKCMWEMTM+UTILMD:D:11A:UN:S2.1'
BGM+E03+DA772411120822489903323000007450202'
DTM+137:202506241231?+00:303'
NAD+MS+9903729000007::293'
CTA+IC+:P GETTY'
COM+?+3222271020:TE'
NAD+MR+9900327000009::293'
IDE+24+24062416225400000000000102159662011'
STS+7++ZY0'
STS+E01++A02:E_0408::1'
STS+E01++A02:E_0408::2'
LOC+Z20+D417MLM8164'
RFF+Z13:55623'
RFF+TN:TR1234'
RFF+Z48::1'
DTM+Z25:202506232200?+00:303'
DTM+Z26:202507232200?+00:303'
RFF+Z48::2'
DTM+Z25:202507232200?+00:303'
SEQ+ZG4+1'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z43:100:KWT'
CCI+Z17'
CAV+ZE5'
CAV+Z87'
CAV+ZG8'
CAV+ZH1'
CAV+ZH5'
CCI+Z63'
CAV+ZH8'
SEQ+ZG4+2'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z43:100:KWT'
CCI+Z17'
CAV+ZE5'
CAV+Z87'
CAV+ZG8'
CAV+ZH1'
CAV+ZH5'
CCI+Z63'
CAV+ZH8'
UNT+44+DAVAXCKCMWEMTM'
UNZ+1+DADXWTWIXOZLUK'[1 item
{6 fields
"data": {3 fields
"stammdaten": {3 fields
"VERWENDUNGSZEITRAUM": [2 items
{6 fields
{5 fields
"TECHNISCHE_RESSOURCE": [2 items
{16 fields
"gueltigkeitszeitraum": {3 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
{16 fields
"gueltigkeitszeitraum": {2 fields
"nennleistung": {1 field
"verbrauchsart": [1 item
"STEUERBARE_RESSOURCE": [1 item
{4 fields
"transaktionsdaten": {13 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"rufnummern": [1 item
{2 fields
"empfaenger": {5 fields
"antwortStatusZeitraum": [2 items
{3 fields
{3 fields
Download: EDIFACT file · BO4E JSON
Example 4
UNA:+.? '
UNB+UNOC:3+9903729000007:500+9900327000009:500+{{date}}:{{time}}+DAIPVTACHLWIBI'
UNH+DAXLMIYYQVOZBM+UTILMD:D:11A:UN:S2.1'
BGM+E03+DA252411120827059903323000007891197'
DTM+137:202506241231?+00:303'
NAD+MS+9903729000007::293'
CTA+IC+:P GETTY'
COM+?+3222271020:TE'
NAD+MR+9900327000009::293'
IDE+24+24062416225400000000000102159662011'
STS+7++ZY0'
STS+E01++A02:E_0408::1'
STS+E01++A02:E_0408::2'
LOC+Z20+D417MLM8164'
RFF+Z13:55623'
RFF+TN:TR1234'
RFF+Z48::1'
DTM+Z25:202506232200?+00:303'
DTM+Z26:202507232200?+00:303'
RFF+Z48::2'
DTM+Z25:202507232200?+00:303'
SEQ+ZG4+1'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z44:100:KWT'
CCI+Z50'
CAV+ZF5'
SEQ+ZG4+2'
RFF+Z38:C816417ST77'
RFF+Z32:E1688117482'
QTY+Z44:100:KWT'
CCI+Z50'
CAV+ZF5'
UNT+32+DAXLMIYYQVOZBM'
UNZ+1+DAIPVTACHLWIBI'[1 item
{6 fields
"data": {3 fields
"stammdaten": {3 fields
"VERWENDUNGSZEITRAUM": [2 items
{6 fields
{5 fields
"TECHNISCHE_RESSOURCE": [2 items
{11 fields
"gueltigkeitszeitraum": {3 fields
"nennleistung": {1 field
{11 fields
"gueltigkeitszeitraum": {2 fields
"nennleistung": {1 field
"STEUERBARE_RESSOURCE": [1 item
{4 fields
"transaktionsdaten": {13 fields
"absender": {6 fields
"ansprechpartner": {4 fields
"rufnummern": [1 item
{2 fields
"empfaenger": {5 fields
"antwortStatusZeitraum": [2 items
{3 fields
{3 fields
Download: EDIFACT file · BO4E JSON
Belongs to these role views
The check identifier itself carries no market role. This assignment is derived back from the role views in whose process steps it occurs — affected are LF, NB, MSB and ÜNB.
| Role | Party involved | Process | Rulebook | Division | Step |
|---|---|---|---|---|---|
| LF | LF | Order placement for a master data change to the NB (responsible) | GPKE part 4 | Electricity | Step 1 |
| LF | LF | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 2 |
| NB | NB | Order placement for a master data change to the NB (responsible) | GPKE part 4 | Electricity | Step 1 |
| NB | NB | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 2 |
| MSB | MSB | Order placement for a master data change to the NB (responsible) | GPKE part 4 | Electricity | Step 1 |
| MSB | MSB | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 2 |
| ÜNB | ÜNB | Order placement for a master data change to the NB (responsible) | GPKE part 4 | Electricity | Step 1 |
| ÜNB | ÜNB | Master data change initiated by the NB (responsible) | GPKE part 4 | Electricity | Step 2 |
Business classification
| Attribute | Value |
|---|---|
| Use case (AHB) | Response message/request data of the TR |
| AHB | UTILMD AHB electricity |
| Response to check identifier | 55617 |
| Decision tree | E_0408 |
| Transmission channel | AS4 |
This check identifier is used in 2 contexts
Regulatory determination and communication direction depend on the process in which the message is sent. A single entry would be misleading — all placements are therefore listed here.
| Process description / rulebook | Process step | Communication | Action |
|---|---|---|---|
| GPKE part 4 | Master data change initiated by the NB (responsible) | LF → NB | Response message on change |
| GPKE part 4 | Order placement for master data change to NB (responsible) | LF → NB | Order placement of a change of master data from the LF to NB |
One entry from format version 202610
The check identifiers table of format version 202604 does not carry this entry: decision tree. It comes from version 202610. Everything else on this page — use case, rulebook and communication direction — comes from its own version. Before adopting this into an implementation specification, check whether what is stated applies to 202604.
Transaction and responses
Role of this check identifier: response message. Basis: the title or the action of the Prüfi table begins with “response message”. A response message carries no status field and is not a response in the sense of a decision tree.
Responses: No response of this format version names this check identifier as a reference — neither explicitly in the Prüfi table nor via the step sequence. That does not mean there is none; it means that the sources do not record one.
Check identifiers of the same AHB table: No other check identifier of message type UTILMDS has the same row structure in this version.
Editorial — not derived from a source
The period ID of this response comes from the request. Condition [44] requires in STS DE9012: »Es ist die Zeitraum-ID vom DE1156 aus einem passenden SG6 RFF+Z49/Z53 … einzutragen« (the period ID from DE1156 of a matching SG6 RFF+Z49/Z53 of the request). In the JSON it is in transaktionsdaten.antwortStatusZeitraum → zeitraumId (SG4.IDE+24.STS+E01). Its value is the zeitraumId of the request's usage period that the response refers to: stammdaten.VERWENDUNGSZEITRAUM → zeitraumId (SG4.IDE+24.SG6.RFF+[Z49|Z53]).
Source: UTILMD AHB electricity (Knowledge Collection ahb/202604/UTILMDS and ahb/202610/UTILMDS), condition [44] at SG4 STS DE9012; segment mapping of the zeitraumId fields in the check identifier specifications · As of: 2026-09-23 · Applies to format version: 202604, 202610 · To be reviewed by: 2027-04-01
Notes on this page
An * after a field or group name marks a mandatory field or a mandatory group. The type is beside it; where the value ends up in the EDIFACT segment is shown by the info icon next to the field name.
The status column carries two vocabularies because the manual answers two questions: on a group row, Muss, Soll or Kann states whether the EDIFACT segment must be present; on a field row, X states that this qualifier is used in this check identifier. Both are kept exactly as the source records them.
For this check identifier, the application handbook lists 141 rows. They appear in the order of the handbook, indented by segment: a row without a data element opens a segment, the rows below it are its data elements.
The Condition column names the markers under which the handbook ties a row to a prerequisite; their free text is below the table.
The test data contains 4 transactions for this check identifier under the message type utilmd. Each is stored twice — as a EDIFACT message and as a BO4E JSON. That both representations show the same transaction has been recalculated, not assumed: interchange control reference, message reference number, document number, message date, sender and recipient match in all 517 pairs of the format version; check identifier, transaction number and location ID wherever both representations carry them. Not a single attribute contradicts.
Placeholder from the test data set
The test data set carries placeholders instead of valid values: {{date}} and {{time}} in the UNB interchange envelope of every EDIFACT file. The page replaces these on call with the current date and the current time — in the format that applies at the respective position: in the envelope year, month and day as well as hour and minute, two digits each.
<businessKey> stays in place. It is not a time value, and an invented key would look like a valid one.